ThinkServer
Installation and User Guide
Machine Types: 1043, 1044, 4010, and 4011
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Removing or installing the heat sink
assembly .
52
55
60
64
64
64
65
65
65
66
Introduction .
1
1
2
Removing or installing the microprocessor .
Completing the parts replacement .
Installing the server cover
Connecting the cables .
Updating the server configuration
Connecting external devices
5
5
5
7
7
7
7
Features .
Specifications .
Software programs .
67
68
68
75
76
76
77
77
78
78
79
79
EasyStartup .
EasyManage.
Using passwords .
RAID controllers .
Reliability, availability, and serviceability.
Rear view.
Locating parts on the system board
9
9
10
13
13
16
Configuring the onboard SATA software RAID
RAID information .
program
Deleting the RAID volume
79
79
80
80
80
80
Rebuilding the RAID volume
Guidelines
17
17
18
18
19
19
Configuring the Gigabit Ethernet controller.
Basic guidelines .
Handling static-sensitive devices
program
80
81
Removing the server cover .
Installing, removing, or replacing optional hardware
Installing the ThinkServer EasyManage program
devices
20
20
23
32
35
37
DVD drive problems .
General problems.
83
83
84
84
84
Installing or removing a memory module.
Installing or removing the riser card.
Installing, removing, or replacing hardware
problems .
85
85
86
87
devices
Removing or installing the system board
battery .
38
Memory problems
38
40
© Copyright Lenovo 2010, 2011
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Optional-device problems
88
89
90
91
92
92
92
93
94
99
Serial port problems.
Web .
99
100
100
101
101
101
Lenovo Support Web site
Calling for service
Using other services
Solving power problems .
Purchasing additional services
Solving Ethernet controller problems .
Solving undetermined problems .
Event logs .
104
104
104
105
106
106
107
107
server
System event log.
94
95
95
95
Diagnostic LEDs on the front control panel
Appendix A. RAID battery card
Specifications .
97
97
Statement.
107
Appendix B. Getting help and
Before you call.
99
ii ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Important: Each caution and danger statement in this document is labeled with a number. This number
is used to cross reference an English-language caution or danger statement with translated versions of
the caution or danger statement in the Safety Information manual. For example, if a caution statement is
labeled “Statement 1,” translations for this caution statement are in the Safety Information manual under
“Statement 1.”
Be sure to read and understand all caution and danger statements in this document before you perform
the procedures. Read and understand any additional safety information that comes with the server or an
optional device before you install, remove, or replace the device.
Statement 1
DANGER
Electrical current from power, telephone, and communication cables is hazardous.
To avoid a shock hazard:
• Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this
product during an electrical storm.
• Connect all power cords to a properly wired and grounded electrical outlet.
• Connect to properly wired outlets any equipment that will be attached to this product.
• When possible, use one hand only to connect or disconnect signal cables.
• Never turn on any equipment when there is evidence of fire, water, or structural damage.
• Disconnect the attached power cords, telecommunications systems, networks, and modems before you
open the device covers, unless instructed otherwise in the installation and configuration procedures.
• Connect and disconnect cables as described in the following table when installing, moving, or opening
covers on this product or attached devices.
To Connect:
To Disconnect:
1. Turn everything OFF.
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
5. Turn device ON.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
iv ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Statement 2
CAUTION:
When replacing the lithium battery, use only the battery recommended by the manufacturer. If your
system has a module containing a lithium battery, replace it only with the same module type made by
the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or
disposed of. Do not:
• Throw or immerse into water
• Heat to more than 100°C (212°F)
• Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Statement 3
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are
installed, note the following:
• Do not remove the covers. Removing the covers of the laser product could result in exposure to
hazardous laser radiation. There are no serviceable parts inside the device.
• Use of controls or adjustments or performance of procedures other than those specified herein
might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly with optical
instruments, and avoid direct exposure to the beam.
Statement 4
≥ 18 kg (39.7 lb)
< 32 kg (70.5 lb)
≥ 32 kg (70.5 lb)
< 55 kg (121.2 lb)
≥ 55 kg (121.2 lb)
< 100 kg (220.5 lb)
CAUTION:
Use safe practices when lifting.
© Copyright Lenovo 2010, 2011
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
Statement 11
CAUTION:
The following label indicates sharp edges, corners, or joints nearby.
Statement 12
CAUTION:
The following label indicates a hot surface nearby.
vi ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Statement 13
DANGER
Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain
conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed
branch circuit protection requirements. Refer to the information that is provided with your device
for electrical specifications.
Statement 15
CAUTION:
Make sure that the rack is secured properly to avoid tipping when the server unit is extended.
Statement 17
CAUTION:
The following label indicates moving parts nearby.
Statement 26
CAUTION:
Do not place any object on top of rack-mounted devices.
© Copyright Lenovo 2010, 2011
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
viii ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1. General information
This chapter provides some general information about your server.
This chapter contains the following topics:
•
•
•
Introduction
This Installation and User Guide is for your Lenovo® ThinkServer® RD230 server (machine types 1043, 1044,
4010, and 4011). This document contains the following information:
• Setting up and cabling the server
• Starting and configuring the server
• Installing options and replacing customer replaceable units (CRUs)
• Solving problems
The server comes with the ThinkServer EasyStartup DVD to help you configure the hardware, install device
drivers, and install the operating system.
The server comes with a limited warranty. For information about the terms of the warranty and getting
service and assistance, see the Warranty and Support Information on the documentation DVD that comes
with your server.
To obtain the most up-to-date information about the server and other Lenovo products, go to:
Record information about the server in the following table. You will need this information when you register
the server with Lenovo.
Product name
Machine type
Model number
Serial number
ThinkServer RD230
1043, 1044, 4010, or 4011
_____________________________________________
_____________________________________________
The model number and serial number are on the labels on the bottom of the server and on the front, visible
through the bezel.
Notices and statements in the document
The caution and danger statements that appear in this document are also in the multilingual Safety
Information. Each caution and danger statement in this document is labeled with a number. This number is
used to cross reference an English-language caution or danger statement with translated versions of the
caution or danger statement in the Safety Information. See “Related documentation” on page 2 for detailed
information about how to get the various documentation for your server.
© Copyright Lenovo 2010, 2011
1
Download from Www.Somanuals.com. All Manuals Search And Download.
The following notices and statements are used in this document:
• Note: These notices provide important tips, guidance, or advice.
• Important: These notices provide information or advice that might help you avoid problems or
inconvenient situations.
• Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is
placed just before the instruction or situation in which damage could occur.
• Caution: These statements indicate situations that can be potentially hazardous to you. A caution
statement is placed just before the description of a potentially hazardous procedure step or situation.
• Danger: These statements indicate situations that can be potentially lethal or extremely hazardous
to you. A danger statement is placed just before the description of a potentially lethal or extremely
hazardous procedure step or situation.
Related documentation
The Lenovo documentation DVD, which comes with your server, contains documentation for the server in
Portable Document Format (PDF). To view the documentation on the documentation DVD, you need to have
the Adobe Reader 5.0 program or later installed, or the xpdf, which comes with Linux® operating systems.
The following table provides information about the general descriptions of the various documentation
provided with your server and how to obtain all the documentation.
Table 1. Related documentation for the server
Documentation
Description
Location
Hardware Maintenance
Manual
This document provides diagnostic
This document is in English and posted
on the Lenovo Support Web site at
information, parts listing, replacement
procedures for all CRUs, and replacement
procedures for other field replaceable units
(FRUs) replaced by trained service personnel.
Important Notices
This document includes safety and legal
notices that you are expected to read before
using the server.
This document is printed out and
provided in server packaging.
Rack Installation
Instructions
This document provides instructions on how
to install your server in a rack.
The English version of this document is
printed out and provided in the server
packaging. Additional languages are
provided on the documentation DVD
and on the Lenovo Support Web site:
Read Me First
This document directs you to the
documentation DVD for complete warranty
and support information.
This document is printed out and
provided in server packaging.
This document includes translations of all
safety statements used in the ThinkServer
documentation.
Available on the documentation DVD
Available on the documentation DVD
Safety Information
This document includes the warranty
statement and information about how to
contact Lenovo Support.
Warranty and Support
Information
Note: You can obtain all the documentation in PDF for your server from the Lenovo Support Web site at
2
ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2. Server setup roadmap
This chapter provides a general roadmap to guide you through setting up your server.
The server setup procedure varies depending on the configuration of the server when it was delivered. In
some cases, the server is fully configured and you just need to connect the server to the network and an
electrical outlet, and then you can turn on the server. In other cases, the server needs to have hardware
features installed, requires hardware and firmware configuration, and requires the operating system to
be installed.
Table 2. Server setup roadmap
Task
Where to find the information
Unpack
Install hardware
Install the server in the rack
The Rack Installation Instructions manual is printed and also included on the
documentation DVD.
Connect the Ethernet cable
and power cord
Turn on the server to verify
operation
Review the BIOS settings
and customize as needed
Configure RAID (onboard
SATA RAID or the installed
SAS RAID adapter)
Check for firmware updates
Install operating system and
basic drivers
Install any additional drivers
needed for added features
Refer to the instructions that came with the hardware option.
Configure Ethernet settings
in the operating system
See the operating system help. This step is not required if the operating system was
installed using the ThinkServer EasyStartup program.
Install remote management
applications
Install applications
Refer to the documentation that comes with the applications that you want to install.
© Copyright Lenovo 2010, 2011
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3. Features and technologies
What is included with your server
The RD230 server package includes the server, a power cord, documentation, the documentation DVD, and
software media.
Features
The RD230 server offers the following features and technologies:
• Microprocessor(s): The server supports up to two Intel® Xeon® dual-core, quad-core, or hex-core
microprocessors.
• BIOS: The server firmware defines a standard interface between the operating system, platform firmware,
and external devices.
• EasyStartup DVD: The ThinkServer EasyStartup program guides you through the configuration of the
hardware, the redundant array of independent disks (RAID) controller, and the installation of the operating
system and device drivers.
• Integrated network support: The server comes with two integrated single-port Gigabit Ethernet
controllers and each supports connection to a 10 Mbps, 100 Mbps, or 1000 Mbps network. For more
• Large data-storage capacity and hot-swap capability: Some hot-swap server models support four
3.5-inch hot-swap hard disk drives. With the hot-swap feature, you can add, remove, or replace hard disk
drives without turning off the server.
• Large system-memory capacity: The server supports up to 64 GB of system memory. The memory
module supports error correcting code (ECC) for up to eight industry-standard single-rank or dual-rank,
1333 MHz, DDR3 (third-generation double-data-rate) registered synchronous dynamic random access
memory (SDRAM) dual inline memory modules (DIMMs).
• High-performance graphics controller: The server comes with an onboard high-performance graphics
controller that supports high resolutions and includes many performance-enhancing features for the
operating-system environment.
• Redundant connection: The two onboard network interface controllers (NIC) provide a failover capability
to a redundant Ethernet connection. If a problem occurs with the primary Ethernet connection, all
Ethernet traffic that is associated with the primary connection is automatically switched to the redundant
NIC. If the applicable device drivers are installed, this switching occurs without data loss and without
user intervention.
• Intelligent Platform Management Interface (IPMI) 2.0: The command-line interface provides direct
access to server management functions through the IPMI 2.0 protocol. Use the command-line interface
to issue commands to control the server power, view system information, and identify the server. You can
also save one or more commands as a text file and run the file as a script.
• RAID support: The server supports the onboard SATA software RAID and an add-on SAS RAID card
(ThinkServer 8708ELP SAS RAID Adapter, ThinkServer 8708EM2 RAID Adapter, or ThinkServer RAID
700 Adapter), which are required for you to use the hot-swap SATA or SAS hard disk drives and to
create the RAID configurations.
Specifications
The following information is a summary of the features and specifications of the server. Depending on the
server model, some features might not be available, or some specifications might not apply.
© Copyright Lenovo 2010, 2011
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3. Features and specifications
Environment:
• Air temperature:
Microprocessor(s): Supports up to
two Intel Xeon dual-core, quad-core,
or hex-core microprocessors. For the
specific type and speed information
about the microprocessor, use
Optical drive:
• Slim DVD/RW
– Server on: 10°C to 35°C (50°F
to 95°F); altitude: 0 to 914.4 m
(3 000 ft)
– Server on: 10°C to 32°C (50°F
to 89.6°F); altitude: 914.4 m (3
000 ft) to 2 133.6 m (7 000 ft)
– Server off: 10°C to 43°C (50°F
to 109.4°F); maximum altitude:
2 133.6 m (7 000 ft)
Hard disk drive expansion bays
(depending on the model):
the Setup Utility program. See
page 67. For a list of the supported
microprocessors for your server, go to
On the ThinkServer systems page,
click Products ➙ Options ➙
Up to four 3.5-inch SATA or SAS hard
disk drives
Expansion slots:
– Shipping: -40°C to 60°C (-104°F
to 140°F)
• Three PCI Express slots on the
system board and the PCI Express
x16 slot is for a riser card (there is
one PCI Express x16 slot on the
riser card)
ThinkServer Processors.
• Humidity:
– Server on: 8-90%,
non-condensing
– Server off: 8-90%,
non-condensing
Memory modules:
• Minimum system memory: 2 GB
• Maximum system memory: 64 GB
(eight memory slots, each with one Power supply: Single 600-watt
– Shipping and storage: up to
93%, non-condensing
• Particulate contamination:
8 GB RDIMM installed)
• Types: ECC, 1333 MHz, DDR3
registered SDRAM DIMMs only
• Slots: Eight dual inline memory
module (DIMM) slots
• Supports 2 GB, 4 GB, and 8 GB
RDIMMs
power supply
System fans: Five system fans
with automatic energy-saving noise
reduction technology
Attention: Airborne particulates
and reactive gases acting alone
or in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server.
Integrated functions:
• Two single-port Gb Ethernet
controllers
• Six USB 2.0 connectors (two front
and four rear)
Integrated graphics card:
• 8 MB video memory
Size:
• Two RJ-45 Ethernet connectors
• One serial port
• One Video Graphics Array (VGA)
monitor connector
• Height: 43.6 mm (1.72 inches)
• Width: 436 mm (17.17 inches)
• Depth: 568 mm (22.36 inches)
• Maximum weight: 17 kg (37.48 lb)
when fully configured
6
ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3. Features and specifications (continued)
RAID controllers:
Electrical input
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
• Onboard SATA Software RAID
• Input voltage:
– Low range:
• ThinkServer 8708ELP SAS RAID
Adapter
Minimum: 100 V ac
• ThinkServer 8708EM2 RAID
Adapter
Maximum: 127 V ac
Input frequency range: 50 to
60 Hz
• ThinkServer RAID 700 Adapter
2. The sound levels were measured
in controlled acoustical
– High range:
environments according to
the procedures specified by the
American National Standards
Institute (ANSI) S12.10 and
ISO 7779 and are reported in
accordance with ISO 9296.
Actual sound-pressure levels in a
given location might exceed the
average values stated because
of room reflections and other
nearby noise sources. The
noise emission level stated
is the declared (upper limit)
sound-power level, in bels, for a
random sample of system.
Minimum: 200 V ac
Maximum: 240 V ac
Input frequency range: 50 to
60 Hz
3. There is no keyboard connector
or mouse connector on the
server. You can connect a USB
keyboard and USB mouse to
the server by using the USB
connectors.
Software programs
Lenovo provides software to help get your server up and running.
EasyStartup
The ThinkServer EasyStartup program simplifies the process of configuring RAID and installing supported
Microsoft® Windows® and Linux operating systems and device drivers on your server. The EasyStartup
program is provided with your server on the ThinkServer EasyStartup DVD. The DVD is self-starting
(bootable). The user guide for the EasyStartup program is on the DVD and can be accessed directly from the
program interface. For additional information, see “Using the ThinkServer EasyStartup program” on page 76.
EasyManage
The ThinkServer EasyManage Agent enables this server to be managed by the centralized console of an
EasyManage Core Server over the network. The ThinkServer EasyManage Agent is supported on 32-bit and
64-bit Windows, Red Hat, and SUSE operating systems.
Reliability, availability, and serviceability
Reliability, availability, and serviceability (hereafter referred to as RAS) are three important server design
features. The RAS features help you to ensure the integrity of the data stored on the server, the availability of
the server when you need it, and the ease with which you can diagnose and correct problems.
Chapter 3. Features and technologies
Download from Www.Somanuals.com. All Manuals Search And Download.
7
The server has the following RAS features:
• Advanced Configuration and Power Interface (ACPI)
• Advanced Desktop Management Interface (DMI)
• Automatic memory downsizing on error detection
• Automatic restart on non-maskable interrupt (NMI)
• Availability of microcode level
• Built-in, menu-driven setup, system configuration, and RAID configuration
• Built-in monitoring for fan, temperature, and voltage
• Cooling fans with speed-sensing capability
• ECC DDR3 SDRAM with Serial Presence Detect (SPD)
• Error codes and messages to help you identify problems
• Generating error logs for the power-on self-test (POST) failures
• Hot-swap SAS hard disk drives
• Integrated Ethernet controllers
• Intelligent Platform Management Interface (IPMI) 2.0
• Power-on self-test (POST)
• Redundant Ethernet connection with failover capability (requires an optional Ethernet card)
• Standby voltage for system-management features and monitoring
• System-error light-emitting diode (LED) on the front panel
• Vital product data (VPD), including the serial number information and replacement part numbers, stored in
the nonvolatile memory for easier remote maintenance
8
ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4. Locating parts, controls, LEDs, and connectors
This chapter provides information to help you locate your server parts, controls, light-emitting diodes
(LEDs), and connectors.
Front view
The following illustration shows the drives and parts on the front of the server.
Figure 1. Front view of the server
1 Slim optical drive
3 Mounting point for 3.5-inch hard disk drive
Rear view
The following illustration shows the locations of the connectors and parts on the rear of the server.
Figure 2. Rear view of the server
1 Power supply 1
6 Serial port
2 Power supply 2 bay (blank and
7 USB connectors (3 and 4)
covered by a bay bezel)
3 Power cord connector
4 USB connectors (1 and 2)
5 VGA monitor connector
8 Ethernet connector 1
9 Ethernet connector 2 (share with MGMT)
10 PCI expansion slot
© Copyright Lenovo 2010, 2011
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Connector
Power cord connector
Ethernet connector
Serial port
Description
Used to connect the power cord.
Used to attach an Ethernet cable for a local area network (LAN).
Used to attach a device that uses a 9-pin serial port.
USB connector
Used to attach a device that uses a USB connector, such as a USB keyboard
or a USB mouse.
VGA monitor connector
Used to attach a VGA monitor or other devices that use a VGA monitor connector.
Front control panel
This section provides information about the front control panel of the server.
The following illustration helps you identify the connectors, controls, and LEDs on the front control panel of
your server.
Figure 3. Front control panel locations
7 Ethernet 2 status LED
8 Hard disk drive status LED
9 Power button and LED
10 System ID LED
1 USB connector
2 USB connector
3 ID button
4 NMI button
5 Reset button
6 Ethernet 1 status LED
11 System status LED
12 LED (will not be used in this server)
The following table describes the meaning of the LEDs on the front control panel.
Table 4. Front control panel LEDs
LED
State
On
Color
Green
Green
Off
Description
The server power is on.
Power LED
Blinking
Off
The server power is under S1.
The server power is off.
The hard disk drive is not active.
The hard disk drive is active.
LAN is linked.
Hard disk drive
LED
Off
Off
Blinking
On
Green
Green
Green
Off
Ethernet 1
status LED
Blinking
Off
LAN is active.
LAN is not linked.
10 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 4. Front control panel LEDs (continued)
LED
State
On
Color
Green
Green
Off
Description
Ethernet 2
status LED
LAN is linked.
LAN is active.
LAN is not linked.
Blinking
Off
Red
Off
System status
LED
On
Failure. Over temperature or over voltage.
No failure.
Off
ID LED
Blue
Off
On
System is identified.
Off
System is not identified.
Each hard disk drive has two status LEDs on the front. The green LED 1 (bottom) indicates activity and
the amber LED 2 (top) indicates the RAID status.
Notes: If the onboard SATA and onboard SATA software RAID are configured, note the following:
• The SGPIO connector of the 4–port SATA cable in the chassis should be connected to the J45 connector
on the system board. See “Locating parts on the system board” on page 13.
• The function of the amber LED 2 is only available after you enter the operating system.
Table 5. Hard disk drive LEDs
Green LED 1
Description
Hard disk drive is not present.
(bottom)
Amber LED 2 (top)
Off
On
Off
Off
Off
Hard disk drive is present but is not active.
Hard disk drive is present and active.
Server is in the process of locating the hard disk drive.
RAID has failed.
Blinking
On
Blinking
On
Off
Hard disk drive is rebuilding.
Blinking
Blinking
Note: For some models, the hard disk drive status information might be different from the information listed in
the above table. For these server models, refer to the following two tables for the hard disk drive LED status.
Table 6. Hard disk drive LEDs for the onboard SATA and onboard SATA software RAID configurations (some models)
Green LED 1
Description
Hard disk drive is not present.
(bottom)
Amber LED 2 (top)
Off
On
Off
Off
Off
Off
Off
Off
Hard disk drive is present but is not active.
Hard disk drive is present and active.
Server is in the process of locating the hard disk drive.
RAID has failed.
Blinking
On
On
Hard disk drive is rebuilding.
Blinking
Chapter 4. Locating parts, controls, LEDs, and connectors 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7. Hard disk drive LEDs for the add-on SAS RAID adapter configuration (some models)
Green LED 1
Description
Hard disk drive is not present.
(bottom)
Amber LED 2 (top)
Off
On
Off
Off
Off
Hard disk drive is present but is not active.
Hard disk drive is present and active.
Server is in the process of locating the hard disk drive.
RAID has failed.
Blinking
Blinking
Off
Blinking
On
Hard disk drive is rebuilding.
Blinking
Blinking
The Ethernet 1 and Ethernet 2 connectors have two status LEDs that indicate the LAN connection and
activity of the connection.
Table 8. Ethernet LEDs
LED
State
Color
Green
Description
10/100/1000 Mb linked
RJ-45 linkage/activity (left)
On
Blinking
Off
Green
Off
10/100/1000 Mb activity
No LAN connection.
Amber
Green
Off
1000 Mb linked and active
100 Mb linked and active
10 Mb mode or no LAN connection.
RJ-45 speed (right)
On
On
Off
12 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Locating server components
The following illustration shows the locations of the major components in your server.
Figure 4. Server component locations
1 Left handle of the chassis
2 Slim optical drive
3 PCI card
6 Heat sink assembly and microprocessor(s) underneath
7 System fans
8 Right handle of the chassis
9 Mounting points for the 3.5-inch hard disk drives
4 Memory modules
5 Power supply assembly
Locating parts on the system board
The following illustrations show the locations of the parts on the system board.
Chapter 4. Locating parts, controls, LEDs, and connectors 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. Locating major parts on the system board
1 Memory slot (CPU1 DIMM CHA1)
2 Memory slot (CPU1 DIMM CHA0)
3 Memory slot (CPU1 DIMM CHB0)
4 Memory slot (CPU1 DIMM CHC0)
5 Power connector 2 (for CPU0)
6 24-pin power connector for the system board
7 Microprocessor (CPU0)
13 SATA connector 1
14 SATA connector 2
15 SATA connector 3
16 SATA connector 5
17 SATA connector 4
18 System board battery
19 PCI Express x8 slot (for the riser card)
20 PCI Express x8 slot (for the riser card)
21 PCI Express x16 slot (for the riser card)
22 Microprocessor (CPU1)
23 Power connector 3 (for CPU1)
8 Memory slot (CPU0 DIMM CHA1)
9 Memory slot (CPU0 DIMM CHA0)
10 Memory slot (CPU0 DIMM CHB0)
11 Memory slot (CPU0 DIMM CHC0)
12 SATA connector 0
14 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 6. Locating other connectors on the system board
1 J47 (system fan 1 connector)
2 J48 (system fan 2 connector)
3 J50 (system fan 3 connector)
4 J56 (system fan 4 connector)
7 J35 (for front control cable)
8 JP1 (Clear CMOS jumper)
9 USB 2 connector
10 J45 connector (for the SGPIO connector of the 4–port SATA cable)
5 J49 (system fan 5 connector)
11 JP8 (COM2 connector)
6 J19 (front USB connector)
The following table introduces the jumper switches on the system board.
Table 9. Jumper settings
Jumper
Position
Pins 1-2
Description
JP1: Clear
CMOS
The default position at which the jumper is placed on pins 1-2 during the normal
operation of the system.
Pins 2-3
If the jumper is placed on pins 2-3, when the jumper is moved back to the default
position, the settings of CMOS will be cleared automatically at the next startup.
Note: Before clearing the CMOS, turn off the server and disconnect the power cord. Move the jumper from
pins 1-2 to pins 2-3. Wait more than five minutes and then move the jumper back to the normal position
(pins 1-2) to clear CMOS.
Chapter 4. Locating parts, controls, LEDs, and connectors 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Locating connectors on the backplane
The following illustration shows the connector locations on the backplane.
Figure 7. Backplane connector locations
1 Power connector 2
3 Optical drive power connector
2 Power connector 1
4 Mini-SAS signal cable connector
16 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5. Installing, removing, or replacing hardware
This chapter provides instructions on how to install, remove, or replace hardware for your server.
This chapter contains the following topics:
•
•
•
•
•
Guidelines
This section provides some guidelines that you should read and understand before using your server.
Basic guidelines
Before you use the server, be sure to read and understand the following guidelines:
• Be sure to read and understand the Safety Information and the Warranty and Support Information on the
help you work safely. To obtain a copy of the publications, go to:
• When you install your new server, take the opportunity to download and apply the most recent firmware
updates. This step will help you to ensure that any known issues are addressed and the server is ready to
function at optimal performance. To download firmware updates for your server, do the following:
2. Click Download & Drivers ➙ ThinkServer and then follow the instructions on the Web page to
download firmware updates for your server.
• Observe good housekeeping in the area where you are working. Put removed covers and other parts
in a safe place.
• If you must turn on the server while the server cover is removed, make sure that no one is near the server
and that no tools or other objects have been left inside the server.
• Do not attempt to lift an object that you think is too heavy for you. If you have to lift a heavy object,
observe the following precautions:
– Make sure that you can stand safely without slipping.
– Distribute the weight of the object equally between your feet.
– Use a slow lifting force. Never move suddenly or twist when you lift a heavy object.
– To avoid straining the muscles in your back, lift by standing or by pushing up with your leg muscles.
• Make sure that you have an adequate number of properly grounded electrical outlets for the server,
monitor, and other devices.
• Back up all important data before you make changes to drives.
• Have a small flat-blade screwdriver available.
• To view the error LEDs on the system board and internal components, leave the server connected to
power.
© Copyright Lenovo 2010, 2011
17
Download from Www.Somanuals.com. All Manuals Search And Download.
• You do not have to turn off the server to install or replace hot-swap fans, redundant hot-swap ac power
supplies, or hot-plug USB devices. However, you must turn off the server before performing any steps that
involve installing, removing, or replacing adapter cables or non-hot-swap optional devices or components.
• After completing any installation, removal, or replacement procedure, reinstall all safety shields, guards,
labels, and ground wires.
• When working inside the server, you might find some tasks easier if you lay the server on its side.
System reliability guidelines
To help ensure proper cooling and system reliability, make sure that you follow these guidelines:
• Every drive bay has an internal drive installed or an Electro Magnetic Compatibility (EMC) shield installed.
• If the server has redundant power, every power supply bay has a power supply assembly installed.
• Leave adequate space around the server to make sure that the server cooling system works well.
• Properly route the cables. For some options, such as PCI cards, follow the cabling instructions that
come with the options.
• Make sure that you replace a failing fan within 48 hours.
• When replacing a hot-swap drive, install the new hot-swap drive within two minutes of removal.
• Do not remove any air duct or air baffles while the server is running. Operating the server without the
air duct or air baffles might cause the microprocessor to overheat.
• The second microprocessor socket always contains either a microprocessor socket cover or a
microprocessor.
Handling static-sensitive devices
Attention:
Do not open the static-protective package containing the new part until the defective part has been removed from the
server and you are ready to install the new part. Static electricity, although harmless to you, can seriously damage
server components and parts.
When you handle server parts and components, take these precautions to avoid static-electricity damage:
• Limit your movement. Movement can cause static electricity to build up around you.
• Wear an electrostatic-discharge wrist strap, if one is available.
• Always carefully handle the parts and other components (such as PCI cards, memory modules, system
boards, and microprocessors) by its edges or its frame. Do not touch solder joints, pins, or exposed
circuitry.
• Prevent others from touching the parts and other computer components.
• Before you replace a new part, touch the static-protective package containing the new part to a metal
expansion-slot cover or other unpainted metal surface on the server for at least two seconds. This
reduces static electricity from the package and your body.
• Remove the new part from the static-protective package and directly install it in the server without
placing it on any other surface. If it is hard for you to do this in your specific situation, place the
static-protective package of the new part on a smooth, level surface, and then place the new part on
the static-protective package.
• Do not place the part on the server cover or other metal surface.
• Take additional care when handling devices during cold weather. Heating reduces indoor humidity
and increases static electricity.
18 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Working inside the server with the power on
Attention:
Static electricity that is released to internal server components when the server is turned on might cause the server to
halt, which might result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist
strap or other grounding system when you work inside the server with the power on.
The server supports hot-swap devices and is designed to operate safely while it is turned on and the cover is
removed. Follow these guidelines when you work inside the server with the power on:
• Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts before working inside
the server; do not wear cuff links while you are working inside the server.
• Do not allow your necktie or scarf to hang inside the server.
• Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist watches.
• Remove items from your shirt pocket, such as pens and pencils. These items might fall into the server as
you lean over it.
• Avoid dropping any metallic objects into the server, such as paper clips, hairpins, and screws.
Removing the server cover
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the server cover.
Attention: For proper cooling and airflow, install the server cover before turning on the server. Operating the
server for more than 30 minutes with the server cover removed might damage server components.
To remove the server cover, do the following:
1. Remove all media from the drives. Then, turn off all attached devices and the server.
2. Disconnect all power cords from electrical outlets.
3. Disconnect the power cord(s), Input/Output (I/O) cables, and all other cables that are connected to
the server.
Chapter 5. Installing, removing, or replacing hardware 19
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Loosen the thumbscrew in the rear of the server cover 1 . Then, slide the server cover to the rear until
you can lift it up to completely remove it from the chassis 2 .
Notes:
a. The thumbscrew is securely installed and you need to use a tool, for example a screw driver, to
loosen it.
b. The thumbscrew is an integrated part of the server cover and it cannot be removed from the server
cover.
Figure 8. Removing the server cover
Installing, removing, or replacing optional hardware devices
This section provides instructions on how to install, remove, or replace optional hardware devices for your
server. You can expand the capabilities of your server by adding memory modules, PCI cards, or drives,
and maintain your server by replacing the failing optional hardware devices. If you are replacing an optional
hardware device, perform the removal procedure and then perform the installation procedure for the optional
hardware device that you want to replace.
Installing or removing a memory module
This section provides instructions on how to install or remove a memory module. For a list of the supported
page, click Products ➙ Options ➙ ThinkServer Memory.
Memory module installation rules
Your server has eight memory slots for installing or replacing DDR3 SDRAM DIMMs that provide up to a
maximum of 64 GB of system memory.
The following tables provide information about the memory module installation rules that you should
consider when installing a memory module. The “X” mark indicates the suggested memory slot(s) into
which the memory module(s) should be installed in different situations. The number, for example 1, 2, or 3,
indicates the installation sequence. See “Locating parts on the system board” on page 13 to identify the
various memory slots.
20 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: All memory module types and capacities must be consistent.
Table 10. DIMM installation rules when a single microprocessor (CPU0) is installed
DIMM slot
One DIMM
Two DIMMs
Three DIMMs
Four DIMMs
X, 4
CPU0 DIMM CHA1
CPU0 DIMM CHA0
CPU0 DIMM CHB0
CPU0 DIMM CHC0
X
X, 1
X, 2
X, 1
X, 2
X, 3
X, 1
X, 2
X, 3
Note: Installing DIMMs on channel A and channel B of CPU0 should enable Channel Mirroring Mode. This mode
requires that you install the DIMMs in pair, and the DIMM installation for Channel Mirroring Mode is one DIMM on
CPU0 DIMM CHA0 and one DIMM on CPU0 DIMM CHB0 when a single microprocessor (CPU0) is installed.
Table 11. DIMM installation rules when two microprocessors (CPU0 and CPU1) are installed
DIMM slot
Two DIMMs
Four DIMMs
Six DIMMs
Eight DIMMs
X, 7
CPU0 DIMM CHA1
CPU0 DIMM CHA0
CPU0 DIMM CHB0
CPU0 DIMM CHC0
CPU1 DIMM CHA1
CPU1 DIMM CHA0
CPU1 DIMM CHB0
CPU1 DIMM CHC0
X, 1
X, 1
X, 3
X, 1
X, 3
X, 5
X, 1
X, 3
X, 5
X, 8
X, 2
X, 2
X, 4
X, 2
X, 4
X, 6
X, 2
X, 4
X, 6
Note: For the Channel Mirroring Mode, it requires that you install the DIMMs in pair, and the DIMM installation for
Channel Mirroring Mode when two microprocessors (CPU0 and CPU1) are installed is shown below. Follow this
sequence rather than the sequence listed above if you want to use the Channel Mirroring Mode.
1. Pair 1: install a DIMM on CPU0 DIMM CHA0 and then install a DIMM on CPU0 DIMM CHB0.
2. Pair 2: install a DIMM on CPU1 DIMM CHA0 and then install a DIMM on CPU1 DIMM CHB0.
Installing a memory module
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install a memory module.
To install a memory module, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Locate the appropriate memory slot on the system board into which you will install the memory module.
To optimize system performance, follow the related memory module installation rules and install the
memory module into a memory slot starting with the memory module farthest from the microprocessor.
Chapter 5. Installing, removing, or replacing hardware 21
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Open the retaining clips of the memory slot into which you want to install the memory module.
Figure 9. Opening the retaining clips of the memory slot
5. Touch the static-protective package that contains the new memory module to any unpainted metal
surface on the outside of the server. Then, remove the new memory module from the package.
6. Position the new memory module over the memory slot. Make sure that the notch 1 on the new memory
module is aligned with the key 2 in the memory slot. Then, press the new memory module straight down
into the memory slot until the retaining clips close and the new memory module snaps into position.
Note: If there is a gap between the memory module and the retaining clips, the memory module has
not been correctly installed. Open the retaining clips, remove the memory module, and then reinstall it
into the slot.
Figure 10. Installing the memory module
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing a memory module
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove a memory module.
To remove a memory module, do the following:
22 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Locate the memory slot with the memory module that you want to remove. See “Locating parts on the
system board” on page 13 for the locations of the memory slots.
4. Carefully open the retaining clips on each end of the memory slot and then grasp the memory module
straight up by its edges.
Figure 11. Removing the memory module
5. If you are instructed to return the failing memory module, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing or installing internal drives
This section provides instructions on how to remove or install internal drives for the server.
See “Specifications” on page 5 for information about the types of internal drives that the server supports and
other important information, and see “Front view” on page 9 for the locations of the drive bays in the server.
When installing an internal drive, be sure to consider the following information:
• Make sure that you have all the cables and other equipment that is specified in the documentation that
comes with the drive.
• Select the drive bay in which you want to install the drive.
• Check the instructions that come with the drive to see whether you have to set any switches or jumpers
on the drive. If you are installing a SAS device, be sure to set the SAS ID for that device.
• The EMI integrity and cooling of the server are protected by having all bays, PCI slots, and PCI Express
slots covered or occupied. When you install a drive, PCI card, or PCI Express card, save the EMC
shield and filler panel from the bay, PCI card slot, or PCI Express card slot in the event that you later
remove the device.
• For a list of the supported hard disk drives for your server, go to http://www.lenovo.com/thinkserver. On
the ThinkServer systems page, click Products ➙ Options ➙ ThinkServer Hard Drives.
Chapter 5. Installing, removing, or replacing hardware 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the optical drive
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the optical drive.
To remove the optical drive, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Disconnect the power cable from the optical drive power connector on the backplane. See “Locating
4. Disconnect the signal cable from the SATA 5 connector on the system board. See “Locating parts on
the system board” on page 13.
5. Press the retention tab 1 and slide the optical drive out of the front of the server.
Figure 12. Removing the optical drive
6. Disconnect the power cable and the signal cable from the rear of the removed optical drive.
24 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Remove the optical drive retention tab by removing the two screws that secure the tab. Save the
retention tab to use when you install a new optical drive.
Figure 13. Removing the optical drive retention tab
8. If you are instructed to return the removed optical drive, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the optical drive
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the optical drive.
To install the optical drive, do the following:
1. If you are replacing the optical drive, make sure that:
• You have all the cables and other equipment that is specified in the documentation that comes
with the new optical drive.
• You have checked the instructions that come with the new optical drive to determine whether you
must set any switches or jumpers in the drive.
• You have removed the retention tab from the rear of the old optical drive and have it available for
installation on the new optical drive.
Note: If you are installing a drive that contains a laser, observe the following safety precautions.
Statement 3
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are
installed, note the following:
• Do not remove the covers. Removing the covers of the laser product could result in exposure
to hazardous laser radiation. There are no serviceable parts inside the device.
• Use of controls or adjustments or performance of procedures other than those specified herein
might result in hazardous radiation exposure.
Chapter 5. Installing, removing, or replacing hardware 25
Download from Www.Somanuals.com. All Manuals Search And Download.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly with optical
instruments, and avoid direct exposure to the beam.
2. Touch the static-protective package that contains the new optical drive to any unpainted metal surface
on the server. Then, remove the optical drive from the package and place it on a static-protective
surface.
3. Follow the instructions that come with the optical drive to set jumpers or switches, if there are any.
4. Install the two screws to secure the retention tab to the rear of the new optical drive. Then, connect the
signal cable 1 and the power cable 2 to the rear of the new optical drive.
Figure 14. Installing the retention tab and connecting the cables
26 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Route the cables through the drive bay hole in the front and then slide the optical drive into the drive
bay until it snaps into position.
Figure 15. Installing the optical drive
6. Connect the power cable to the optical drive power connector on the backplane. See “Locating
7. Connect the signal cable to the SATA 5 connector on the system board. See “Locating parts on the
system board” on page 13.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing a hot-swap hard disk drive
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove a hot-swap hard disk drive. This section applies only to
server models that have hot-swap hard disk drives installed.
Attention: To maintain proper system cooling, do not operate the server for more than 10 minutes without
either a drive or a filler panel installed in each drive bay.
To remove a hot-swap hard disk drive, do the following:
Note: You do not have to turn off the server when removing a hot-swap hard disk drive.
Chapter 5. Installing, removing, or replacing hardware 27
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Rotate the drive tray handle 2 of the hard disk drive tray assembly 1 to the open position. Then, grasp
the handle and pull the drive tray assembly with the hard disk drive out of the bay.
Figure 16. Removing the hard disk drive tray assembly with the hard disk drive
2. Remove the screws that secure the hard disk drive in the tray. Then, remove the hard disk drive.
Figure 17. Removing a 3.5-inch hard disk drive
28 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3. If you are instructed to return the removed hard disk drive, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing a hot-swap hard disk drive
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install a hot-swap hard disk drive. This section applies only to
server models that support hot-swap hard disk drives.
Attention: To maintain proper system cooling, do not operate the server for more than 10 minutes without
either a drive or a filler panel installed in each drive bay.
Notes:
1. You do not have to turn off the server for the installation of a hot-swap hard disk drive.
2. The cables come with the SATA hard disk drive option kit will not be used in this server.
To install a hot-swap hard disk drive, do the following:
1. Rotate the drive tray handle 2 of the hard disk drive tray assembly 1 to the open position. Then, grasp
the handle and pull the drive tray assembly out of the bay.
Figure 18. Removing the hard disk drive tray assembly
Chapter 5. Installing, removing, or replacing hardware 29
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Remove the screws that secure the plastic filler and then remove the plastic filler.
Figure 19. Removing the filler
3. Touch the static-protective package that contains the new hard disk drive to any unpainted metal
surface on the server. Then, remove the hard disk drive from the package and place it on a
static-protective surface.
4. Make sure that the drive tray handle is in the open position.
30 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Align the screw holes in both sides of the hard disk drive with the corresponding holes in the tray. Then,
install the screws to secure the hard disk drive in the tray.
Figure 20. Installing a 3.5-inch hard disk drive
6. Keep the handle on the hard disk drive tray assembly fully open, slide the tray with the hard disk drive
into the corresponding mounting point of the hot-swap hard disk drive bay 1 , and then slightly press
the handle to lock the tray into place 2 .
7. Check the hard disk drive status LEDs to make sure that the hard disk drive is operating correctly. You
might have to restart the server for the drive to be recognized. If the amber hard disk drive status LED
for a drive is lit continuously, it indicates that the drive is faulty and must be replaced; if the green hard
disk drive activity LED is flashing, this indicates that the drive is being accessed.
Note: If the server is configured for RAID operation using a RAID controller, you might have to
reconfigure the disk arrays after you replace hard disk drives.
Chapter 5. Installing, removing, or replacing hardware 31
Download from Www.Somanuals.com. All Manuals Search And Download.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing or removing the riser card
This section provides instructions on how to install or remove the riser card.
Installing the riser card
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the riser card. The riser card has a PCI card installed on it.
To install the riser card, do the following:
Note: Use any documentation that comes with the riser card and follow those instructions in addition to
the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Locate the appropriate PCI slot on the system board for installing the riser card. See “Locating parts on
the system board” on page 13.
4. Touch the static-protective package that contains the riser card to any unpainted metal surface on the
server. Then, remove the riser card from the static-protective package.
32 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press the riser card (might having a PCI card installed) down into the appropriate PCI card slot on the
system board. Then, close the retention tab to secure the PCI card (installed on the riser card) and then
install the fastening screw to secure the riser card in place.
Note: The riser card might have a PCI card already installed on it. Carefully fit the PCI card into the
server.
Figure 21. Installing the riser card
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing the riser card
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the riser card with a PCI card installed.
To remove the riser card, do the following:
Chapter 5. Installing, removing, or replacing hardware 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Use any documentation that comes with the riser card and follow those instructions in addition to
the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Disconnect any cables from the PCI card or any cables that impede access to the riser card.
4. Open the retention tab that secures the PCI card, which is installed on the riser card.
Figure 22. Opening the retention tab
34 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Remove the fastening screw that secures the riser card 1 and lift the riser card straight up by its
edges to remove it 2 .
Figure 23. Removing the riser card (with a PCI card installed)
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing or removing a PCI card
This section provides instructions on how to install or remove a PCI card.
Installing a PCI card
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install a PCI card.
To install a PCI card, do the following:
Note: Use any documentation that comes with the PCI card and follow those instructions in addition to
the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
Chapter 5. Installing, removing, or replacing hardware 35
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Install the PCI card into the slot on the riser card.
Figure 24. Installing a PCI card into the slot on the riser card
5. Install the riser card into an appropriate PCI card slot on the system board. See “Installing the riser
6. Connect any cables to the PCI card.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing a PCI card
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove a PCI card.
The PCI card is installed on the riser card. To remove a PCI card, do the following:
Note: Use any documentation that comes with the PCI card and follow those instructions in addition to
the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Disconnect any cables from the PCI card or any cables that impede access to the riser card.
4. Remove the riser card together with the installed PCI card. See “Removing the riser card” on page 33.
36 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Remove the PCI card from the PCI card slot on the riser card.
Figure 25. Removing the PCI card from the riser card
If you are instructed to return the PCI card, follow all packaging instructions and use any packaging materials
that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing or installing the Ethernet card
This section provides instructions on how to remove or install the Ethernet card.
Removing the Ethernet card
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the Ethernet card.
The Ethernet card is installed on the riser card. To remove the Ethernet card, do the following:
Note: Use any documentation that comes with the Ethernet card and follow those instructions in addition to
the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Disconnect any cables that impede access to the riser card.
4. Remove the riser card together with the installed Ethernet card. See “Removing the riser card” on
page 33.
card from the riser card.
6. If you are instructed to return the Ethernet card, follow all packaging instructions and use any packaging
materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Chapter 5. Installing, removing, or replacing hardware 37
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Ethernet card
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the Ethernet card and how to install the Ethernet card
driver on Windows operating systems.
To install the Ethernet card, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Touch the static-protective package that contains the Ethernet card to any unpainted surface on the
outside of the server. Then, remove the Ethernet card from the package.
4. See “Installing a PCI card” on page 35 and follow those instructions to install the Ethernet card.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
On Linux operating systems, you do not need to install any device driver for the Ethernet card; on Windows
operating systems, you need to install the device driver for the Ethernet card. To install the device driver
on Windows operating systems, do the following:
1. Save any open documents and exit all applications.
2. Insert the ThinkServer EasyStartup DVD that came with your server into the DVD drive.
Note: You do not need to use the driver disc that came with the Ethernet card.
3. Right-click My Computer and select Properties. The System Properties window opens.
4. On the Hardware tab, click the Device Manager button. The Device Manager window opens.
5. Expand the Network adapters and then right-click one of the Ethernet cards (PRO/1000PT or the
yellow question mark).
6. Select Update Driver.... The Hardware Update Wizard program opens.
7. Select Install the software automatically (Recommended) and click Next to continue.
8. Follow the instructions on the screen.
Installing, removing, or replacing hardware devices
This section provides instructions on how to install, remove, or replace hardware devices for your server.
You can maintain your server by replacing the failing hardware devices. If you are replacing a hardware
device, perform the removal procedure and then perform the installation procedure for the hardware device
that you want to replace.
Removing or installing the system board battery
This section provides instructions on how to remove or install the system board battery.
38 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the system board battery
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the system board battery.
To remove the system board battery, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Locate the battery on the system board. See “Locating parts on the system board” on page 13.
4. Remove the system board battery.
Figure 26. Removing the system board battery
5. Dispose of the battery as required by local ordinances or regulations.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the system board battery
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the system board battery.
Be sure to consider the following information when you replace the battery in the server:
• You must replace the battery with a lithium battery of the same type from the same manufacturer.
• After you replace the system board battery, you must reconfigure the server and reset the system date
and time.
• To avoid possible danger, read and follow the following safety statement.
Statement 2
CAUTION:
When replacing the lithium battery, use only Part Number 33F8354 or an equivalent type battery
recommended by the manufacturer. If your system has a module containing a lithium battery, replace
it only with the same module type made by the same manufacturer. The battery contains lithium and
can explode if not properly used, handled, or disposed of. Do not:
Chapter 5. Installing, removing, or replacing hardware 39
Download from Www.Somanuals.com. All Manuals Search And Download.
• Throw or immerse into water
• Heat to more than 100°C (212°F)
• Repair or disassemble
To install the system board battery, do the following:
Note: Follow any special handling and installation instructions that come with the replacement battery.
1. Hold the system board battery 1 and position one side of the battery into its socket. Then, press the
other side of the battery until it snaps into place.
Figure 27. Installing the system board battery
2. Make sure that the battery clip holds the battery securely.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation, go to “Completing the parts replacement” on page 64. You need to use the
Setup Utility program and reset the configuration, such as the system date and time and passwords. See
Removing or installing the RAID controller
This section provides instructions on how to remove or install the RAID controller.
Removing the RAID controller
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the RAID controller installed in your server.
Notes:
1. Use any documentation that comes with the RAID controller and follow those instructions in addition to
the instructions in this section.
2. When you disconnect the power source from the server, you lose the ability to view the LEDs because
the LEDs are not lit when the power source is removed. Before you disconnect the power source, make
a note of which LEDs are lit, including the LEDs that are lit on the front control panel.
The RAID controller is installed on the riser card. To remove the RAID controller, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Press the tabs on both sides of the connector on the signal cable towards each other and remove the
cable from the RAID controller.
40 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Disconnect any other cables from the RAID controller or any cables that impede access to the riser card.
5. Remove the riser card together with the installed RAID controller. See “Removing the riser card” on
page 33.
6. Refer to “Removing a PCI card” on page 36 and follow those instructions to remove the RAID controller
from the riser card.
Note: Depending on your RAID controller, if necessary, remove the RAID battery from the RAID
controller by removing the screws that secure the battery on the controller and disconnecting any cables.
7. If you are instructed to return the RAID controller, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the ThinkServer 8708ELP SAS RAID Adapter
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the ThinkServer 8708ELP SAS RAID Adapter (hereafter
referred to as the RAID controller within this section).
To install the RAID controller, do the following:
Note: Use any documentation that comes with the RAID controller and follow those instructions in addition
to the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Touch the static-protective package that contains the RAID controller to any unpainted surface on the
outside of the server. Then, remove the RAID controller from the package.
4. Depending on your RAID controller, you might need to install a ThinkServer 8708ELP SAS RAID
adapter battery (hereafter referred to as the battery card assembly) on the RAID controller. The battery
card assembly mounts directly to the RAID controller through a small board-to-board connector
(daughtercard).
Notes:
a. The battery card assembly protects the integrity of the cached data on the RAID controller by
providing backup power up to 72 hours in the case of a complete ac power failure or a brief power
outage. It has built-in functionality to charge the battery pack automatically and to communicate
battery status information such as voltage, temperature, and current to your server. It also provides
an inexpensive alternative to using an uninterruptible power supply, and a second level of fault
tolerance when used in conjunction with an uninterruptible power supply. For more information about
b. The battery card assembly option kit contains a user guide, the battery card assembly, and three
Phillips-head screws. Do not remove the battery card assembly from the antistatic shipping
container until you are ready to install it. When you remove the battery card assembly from your
server, place it in its original container.
c. Check the appropriate support Web sites for the latest updates for your basic input/output system
(BIOS) code, utility programs, device drivers, and other software applications. Follow the instructions
provided by your Service Provider to download and install updates.
Chapter 5. Installing, removing, or replacing hardware 41
Download from Www.Somanuals.com. All Manuals Search And Download.
d. It is recommended that you replace the battery pack on the battery card assembly annually or after
500 recharging cycles, whichever comes first.
e. The temperature of the battery card assembly is generally 15-20°C (59-68°F) higher than the
ambient temperature during fast charge. Therefore, to complete a fast charge cycle, the ambient
temperature should be lower than 45°C (113°F). If the ambient temperature exceeds 45°C (113°F),
the fast charge cycle will terminate prematurely, thus preventing the battery card assembly from
reaching a fully charged state.
Attention:
• When attaching the battery card assembly to a PCI Express slot, center the Phillips-head screw
driver to avoid damaging the screw head and do not over-tighten the screws as you might damage
the battery card assembly.
• The battery in the battery card assembly must recharge for at least six hours during fast charge
under normal operating conditions.
To install the battery card assembly onto the RAID controller, do the following:
42 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
a. Note the top view and the bottom view of the battery card assembly. Then, insert the battery pack
harness connector into the 5-pin J3 battery pack harness connector on the backside of the battery
card assembly. For more information, refer to the following illustrations.
Figure 28. Top view of the battery card assembly
1 Battery pack harness
Figure 29. Bottom view of the battery card assembly
1 J3 battery pack harness connector
2 J1 connector
3 J2 board-to-board connector
b. With the front side up, place the RAID controller on a flat, clean, static-free surface.
Chapter 5. Installing, removing, or replacing hardware 43
Download from Www.Somanuals.com. All Manuals Search And Download.
c. Hold the battery card assembly with the battery side up and the J2 board-to-board connector lining
up with the J7 BBU connector 1 on the RAID controller. Carefully press the battery card assembly
onto the RAID controller so that the two connectors are firmly joined. Then, secure the battery
card assembly to the RAID controller with the three screws and the standoffs that come with the
battery card assembly accessory kit.
Figure 30. Installing the battery card assembly
1 J7 BBU connector
5. See “Installing a PCI card” on page 35 and follow those instructions to install the RAID controller.
6. Connect the mini SAS signal cable to the RAID controller and mini SAS signal cable connector on the
Note: Use the 440 mm (17.32 inches) mini SAS signal cable.
Figure 31. Connecting the mini SAS signal cable
1 Ports 0-3
2 Ports 4-7 (reserved for use)
What to do next:
• To work with another piece of hardware, go to the appropriate section.
44 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the ThinkServer 8708EM2 RAID Adapter
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This topic provides instructions on how to install the ThinkServer 8708EM2 RAID Adapter (hereafter referred
to as the RAID controller within this topic) and the battery card assembly for this RAID controller.
To install the RAID controller, do the following:
Note: Use any documentation that comes with the RAID controller and follow those instructions in addition
to the instructions in this topic.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
4. Touch the static-protective package that contains the RAID controller to any unpainted surface on the
outside of the server. Then, remove the RAID controller from the package.
5. Depending on your RAID controller, you might need to install a ThinkServer 8708EM2 RAID Adapter
Battery (hereafter referred to as the battery card assembly) on the RAID controller. The battery
card assembly mounts directly to the RAID controller through a small board-to-board connector
(daughtercard).
Notes:
a. The battery card assembly protects the integrity of the cached data on the RAID controller by
providing backup power up to 72 hours in the case of a complete ac power failure or a brief power
outage. It has built-in functionality to charge the battery pack automatically and to communicate
battery status information such as voltage, temperature, and current to your server. It also provides
an inexpensive alternative to using an uninterruptible power supply, and a second level of fault
tolerance when used in conjunction with an uninterruptible power supply. For more information about
b. The battery card assembly option kit contains a user guide, the battery card assembly, and three
Phillips-head screws. Do not remove the battery card assembly from the antistatic shipping
container until you are ready to install it. When you remove the battery card assembly from your
server, place it in its original container.
c. Check the appropriate support Web sites for the latest updates for your basic input/output system
(BIOS) code, utility programs, device drivers, and other software applications. Follow the instructions
provided by your Service Provider to download and install updates.
d. It is recommended that you replace the battery pack on the battery card assembly annually or after
500 recharging cycles, whichever comes first.
e. The temperature of the battery card assembly is generally 15-20°C (59-68°F) higher than the
ambient temperature during fast charge. Therefore, to complete a fast charge cycle, the ambient
temperature should be lower than 45°C (113°F). If the ambient temperature exceeds 45°C (113°F),
the fast charge cycle will terminate prematurely, thus preventing the battery card assembly from
reaching a fully charged state.
Attention:
• When attaching the battery card assembly to a PCI Express slot, center the Phillips-head screw
driver to avoid damaging the screw head and do not over-tighten the screws as you might damage
the battery card assembly.
• The battery in the battery card assembly must recharge for at least six hours during fast charge
under normal operating conditions.
Chapter 5. Installing, removing, or replacing hardware 45
Download from Www.Somanuals.com. All Manuals Search And Download.
To install the battery card assembly onto the RAID controller, do the following:
a. Note the top view and bottom view of the battery card assembly. Then, insert the battery pack
harness connector into the J4 battery pack harness connector on the backside of the battery card
assembly. For more information, refer to the following illustrations.
Figure 32. Top view of the battery card assembly
1 Battery pack harness
Figure 33. Bottom view of the battery card assembly
1 J4 battery pack harness connector
2 J5 board-to-board connector
3 J2 connector
b. With the front side up, place the RAID controller on a flat, clean, static-free surface.
46 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
c. Hold the battery card assembly with the battery side up and the J5 board-to-board connector
lining up with the J10 BBU connector 1 on the RAID controller. Carefully press the battery card
assembly onto the RAID controller so that the two connectors are firmly joined. Then, secure the
battery card assembly to the RAID controller with the three screws and the standoffs that come
with the battery card assembly accessory kit.
Figure 34. Installing the battery card assembly onto the RAID controller
1 J10 BBU connector
6. Connect the mini SAS signal cable to ports 0-3 on the RAID controller.
Note: Use the 400 mm (15.75 inches) mini SAS signal cable.
Figure 35. Connecting the mini SAS signal cable to the RAID controller
1 Ports 0-3
2 Ports 4-7 (reserved for use)
Chapter 5. Installing, removing, or replacing hardware 47
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Install the RAID controller into an appropriate PCI card slot on the riser card assembly. Then, install
the screw to secure the RAID controller in place.
Figure 36. Installing the RAID controller into the PCI card slot on the riser card
8. Install the riser card with the RAID controller into an appropriate PCI card slot on the system board.
9. Connect the other end of the 400 mm (15.75 inches) mini SAS signal cable to the mini SAS signal cable
connector 1 on the backplane of your server.
Figure 37. Mini SAS signal cable connector on the backplane
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the ThinkServer RAID 700 Adapter
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This topic provides instructions on how to install the ThinkServer RAID 700 Adapter (hereafter referred to as
the RAID controller within this topic) and the battery card assembly for this RAID controller.
48 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
To install the RAID controller, do the following:
Note: Use any documentation that comes with the RAID controller and follow those instructions in addition
to the instructions in this topic.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
4. Touch the static-protective package that contains the RAID controller to any unpainted surface on the
outside of the server. Then, remove the RAID controller from the package.
5. Depending on your RAID controller, you might need to install a ThinkServer RAID 700 Adapter Battery
(hereafter referred to as the battery card assembly) on the RAID controller. The battery card assembly
mounts directly to the RAID controller through a small board-to-board connector (daughtercard).
Notes:
a. The battery card assembly protects the integrity of the cached data on the RAID controller by
providing backup power up to 72 hours in the case of a complete ac power failure or a brief power
outage. It has built-in functionality to charge the battery pack automatically and to communicate
battery status information such as voltage, temperature, and current to your server. It also provides
an inexpensive alternative to using an uninterruptible power supply, and a second level of fault
tolerance when used in conjunction with an uninterruptible power supply. For more information about
b. The battery card assembly option kit contains a user guide, the battery card assembly, and three
Phillips-head screws. Do not remove the battery card assembly from the antistatic shipping
container until you are ready to install it. When you remove the battery card assembly from your
server, place it in its original container.
c. Check the appropriate support Web sites for the latest updates for your basic input/output system
(BIOS) code, utility programs, device drivers, and other software applications. Follow the instructions
provided by your Service Provider to download and install updates.
d. It is recommended that you replace the battery pack on the battery card assembly annually or after
500 recharging cycles, whichever comes first.
e. The temperature of the battery card assembly is generally 15-20°C (59-68°F) higher than the
ambient temperature during fast charge. Therefore, to complete a fast charge cycle, the ambient
temperature should be lower than 45°C (113°F). If the ambient temperature exceeds 45°C (113°F),
the fast charge cycle will terminate prematurely, thus preventing the battery card assembly from
reaching a fully charged state.
Attention:
• When attaching the battery card assembly to a PCI Express slot, center the Phillips-head screw
driver to avoid damaging the screw head and do not over-tighten the screws as you might damage
the battery card assembly.
• The battery in the battery card assembly must recharge for at least six hours during fast charge
under normal operating conditions.
To install the battery card assembly onto the RAID controller, do the following:
Chapter 5. Installing, removing, or replacing hardware 49
Download from Www.Somanuals.com. All Manuals Search And Download.
a. Note the bottom view of the battery card assembly.
Figure 38. Bottom view of the battery card assembly
1 J1 board-to-board connector
2 J2 remote connector (reserved for use)
b. With the front side up, place the RAID controller on a flat, clean, static-free surface.
c. Hold the battery card assembly with the battery side up and the J1 board-to-board connector
lining up with the J6B1 BBU connector 1 on the RAID controller. Carefully press the battery card
assembly onto the RAID controller so that the two connectors are firmly joined. Then, secure the
battery card assembly to the RAID controller with the three screws and the standoffs that come
with the battery card assembly accessory kit.
Figure 39. Installing the battery card assembly onto the RAID controller
1 J6B1 BBU connector
50 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Connect the mini SAS signal cable to ports 0-3 on the RAID controller.
Note: Use the 400 mm (15.75 inches) mini SAS signal cable.
Figure 40. Connecting the mini SAS signal cable to the RAID controller
1 Ports 0-3
2 Ports 4-7 (reserved for use)
7. Install the RAID controller into an appropriate PCI card slot on the riser card assembly. Then, install
the screw to secure the RAID controller in place.
Figure 41. Installing the RAID controller into the PCI card slot on the riser card
8. Install the riser card with the RAID controller into an appropriate PCI card slot on the system board.
Chapter 5. Installing, removing, or replacing hardware 51
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Connect the other end of the 400 mm (15.75 inches) mini SAS signal cable to the mini SAS signal cable
connector 1 on the backplane of your server.
Figure 42. Mini SAS signal cable connector on the backplane
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing or installing the heat sink assembly
This section provides instructions on how to remove or install the heat sink assembly.
Removing the heat sink assembly
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the heat sink assembly.
CAUTION:
The heat sink assembly might be very hot. Turn off the server and wait three to five minutes to let the
server cool before removing the server cover.
To remove the heat sink assembly, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
52 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Remove the eight screws that secure the heat sink assembly 1 - 8 and gently lift out the heat sink
assembly.
Figure 43. Removing the heat sink assembly
1 - 8 Screws
9 Air flow
10 Indicates the front of the chassis
4. If you are instructed to return the heat sink assembly, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the heat sink assembly
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the heat sink assembly.
Chapter 5. Installing, removing, or replacing hardware 53
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION:
The heat sink and microprocessor might be very hot. Turn off the server and wait three to five minutes
to let the server cool before removing the server cover.
To install the heat sink assembly, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
3. Position the heat sink assembly in place by aligning the retaining screws on the heat sink assembly with
the corresponding holes in the system board. Then, tighten the eight screws following the numerical
sequence as shown below to secure the heat sink assembly on the system board.
Figure 44. Installing the heat sink assembly
1 - 8 Screws
9 Air flow
10 Indicates the front of the chassis
54 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing or installing the power supply
This section provides instructions on how to remove or install the power supply.
Removing the power supply
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the power supply.
When you remove a power supply, observe the following precautions.
DANGER
Hazardous moving parts. Keep fingers and other body parts away.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
To remove the power supply, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
Chapter 5. Installing, removing, or replacing hardware 55
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Remove the four screws 1 and 2 that secure the power supply.
Figure 45. Removing the screws that secure the power supply
56 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Disconnect the power cables from connectors 3 , 4 , and 5 on the system board, and from connectors
1 and 2 on the backplane.
Figure 46. Disconnecting the power cables
5. Disconnect the power cables from any other cards or devices.
Note: The power cables are part of the power supply. Do not try to remove or disconnect the power
cables from the power supply.
6. Carefully lift the power supply out of the server.
7. If you are instructed to return the power supply, follow all packaging instructions and use any packaging
materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the power supply
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the power supply.
When you install a power supply, observe the following precautions.
Chapter 5. Installing, removing, or replacing hardware 57
Download from Www.Somanuals.com. All Manuals Search And Download.
DANGER
Hazardous moving parts. Keep fingers and other body parts away.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
To install the power supply, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
58 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Carefully place the power supply into the server by aligning the screw holes in the power supply with
the corresponding holes in the chassis. Then, install the four screws 1 and 2 to secure the power
supply in place.
Figure 47. Installing the screws to secure the power supply
Chapter 5. Installing, removing, or replacing hardware 59
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Connect the power cables to the system board connectors 3 , 4 , and 5 , and to the backplane
connectors 1 and 2 .
Figure 48. Connecting the power cables
5. Connect the power cables to any other cards or devices.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Removing or installing the microprocessor
This section provides instructions on how to remove or install the microprocessor.
Removing the microprocessor
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to remove the microprocessor.
CAUTION:
The heat sink and microprocessor might be very hot. Turn off the server and wait three to five minutes
to let the server cool before removing the server cover.
To remove the microprocessor, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
60 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Lift the small handle and open the retainer to access the microprocessor. Then, carefully lift the
microprocessor straight up and out of the socket, and place it on a static-protective surface.
Note: Touch only the edges of the microprocessor.
Figure 49. Removing the microprocessor
5. If you are instructed to return the microprocessor, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Installing the microprocessor
Attention: Do not open your server or attempt any repair before reading and understanding the “Safety information”
This section provides instructions on how to install the microprocessor.
CAUTION:
The heat sink and microprocessor might be very hot. Turn off the server and wait three to five minutes
to let the server cool before removing the server cover.
Note: When you need to install a second microprocessor, first remove the dual heat sink and then
remove excess grease from the first microprocessor and the microprocessor socket area. Make sure the
microprocessor and socket area are clean of grease. Use the new heat sink that comes with the second
Chapter 5. Installing, removing, or replacing hardware 61
Download from Www.Somanuals.com. All Manuals Search And Download.
microprocessor option kit and dispose of the old one. The new heat sink has grease already applied for both
the first and second microprocessors.
For optimal performance, follow these microprocessor installation rules:
1. When two microprocessors are installed, both must have the same core voltage and core speed.
2. When only one microprocessor is installed, it must be in the socket labeled CPU0. The other socket
must be kept empty.
3. Always install the microprocessor first into the CPU0 socket, and then install another microprocessor
into the CPU1 socket if you want to install two microprocessors.
To install the microprocessor, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
4. Press down and push the small handle outward on the microprocessor socket to lift the handle to
the open position.
Figure 50. Lifting the handle
5. Gently press the retainer of the microprocessor socket to open it.
Figure 51. Opening the retainer
62 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Remove the protective cover from the microprocessor socket. To avoid damaging the pins in the
microprocessor socket, do not touch the pins while removing the cover.
Figure 52. Removing the microprocessor socket cover
7. Remove the new microprocessor from the protective cover that protects the gold contacts on the
bottom of the new microprocessor.
Figure 53. Removing the new microprocessor from the protective cover
8. Hold the new microprocessor by the edges and align the notches 1 on it with the tabs 2 in the
microprocessor socket. Then, install the microprocessor into the socket.
Chapter 5. Installing, removing, or replacing hardware 63
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 54. Installing the microprocessor
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Completing the parts replacement
This section provides instructions to help you complete the parts replacement and turn on your server.
To complete the parts replacement, you must reinstall the server cover, reconnect all the cables and, for
some devices, run the Setup Utility program to do further setup.
Installing the server cover
This section provides instructions on how to install the server cover.
Attention: For proper cooling and airflow, install the server cover before turning on the server. Operating
the server for extended periods of time (more than 30 minutes) with the cover removed might damage
server components.
To install the server cover, do the following:
1. Make sure that all cables, add-on cards, and other components are installed and seated correctly and
that you have not left loose tools or parts inside the server. Also, make sure that all internal cables are
correctly routed.
2. Position the server cover on the chassis so that the rail guides on the bottom of the server cover engage
the rails. Then, slide the server cover to the front of the server until it snaps into position and is closed.
Then, tighten the thumbscrew to secure the server cover.
Note: Although the server cover is secured by a thumbscrew, for safety consideration, be sure to use a
tool, for example a screw driver, to tighten the thumbscrew and always make sure that the thumbscrew
is securely installed. Also, do not over-tighten the thumbscrew.
Connecting the cables
Attention: To prevent damage to equipment, connect the power cords last.
If the server cables and connector panel have color-coded connectors, match the color of the cable end with
the color of the connector. For example, match a blue cable end with a blue panel connector, a red cable
64 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
end with a red connector, and so on. See “Rear view” on page 9 for an illustration of the I/O connectors on
the rear of the server.
Turning on the server
When the server is connected to an ac power source but is not turned on, the operating system does not
run, and all core logic except for the service processor (the integrated management module) is shut down;
however, the server can respond to requests to the service processor, such as a remote request to turn on
the server. The power-on LED flashes to indicate that the server is connected to an ac power source but
is not turned on.
Approximately five seconds after the server is connected to ac power, one or more fans might start running
to provide cooling while the server is connected to power and the power-on button LED flashes quickly.
Approximately one to three minutes after the server is connected to ac power, the power-control button
becomes active (the power-on LED flashes slowly), and one or more fans might start running to provide
cooling while the server is connected to power. Then, you can turn on the server by pressing the power
Updating the server configuration
When you turn on the server for the first time after you add or remove a device, you might receive a
message saying that the configuration has been changed. The Setup Utility program starts automatically
Some optional devices have device drivers that you must install. For information about installing device
drivers, see the documentation that comes with each device.
The server comes with at least one microprocessor. If more than one microprocessor is installed, the server
can operate as a symmetric multiprocessing (SMP) server. You might have to upgrade the operating system
to support SMP. For more information, see the operating-system documentation.
If the server has an optional RAID controller and you have installed or removed a hard disk drive, see the
documentation that comes with the RAID controller for information about reconfiguring the disk arrays.
Turning off the server
When you turn off the server and leave it connected to ac power, the server can respond to requests to
the service processor, such as a remote request to turn on the server. While the server remains connected
to ac power, one or more fans might continue to run. To remove all power from the server, you must
disconnect it from the power source.
Some operating systems require an orderly shutdown before you turn off the server. See your
operating-system documentation for information about shutting down the operating system.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
Chapter 5. Installing, removing, or replacing hardware 65
Download from Www.Somanuals.com. All Manuals Search And Download.
The server can be turned off in any of the following ways:
• You can turn off the server from the operating system, if your operating system supports this feature. After
an orderly shutdown of the operating system, the server will turn off automatically.
• You can press the power button to start an orderly shutdown of the operating system and turn off the
server, if your operating system supports this feature.
• If the operating system stops functioning, you can press and hold the power button for more than four
seconds to turn off the server.
• The server can be turned off by the Shutdown on LAN feature.
• The integrated management module (IMM) can turn off the server as an automatic response to a critical
system failure.
Connecting external devices
If you install a supported optional adapter, you can attach external devices to the server.
To attach an external device, do the following:
Note: If you are attaching an external device, see the documentation that comes with the device for
information about cabling.
1. Read and understand the Safety Information on the documentation DVD that comes with your product,
2. Turn off the server and all attached devices.
3. Follow the instructions that come with the device to prepare it for installation and to connect it to
the server.
66 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6. Configuring the server
The following configuration programs come with the server:
• Setup Utility program: The Setup Utility program is part of the server firmware. You can use the Setup
Utility program to view your server configuration, change the startup device sequence, set the date
• Ethernet controller configuration: For information about configuring the Ethernet controller, see
• INTEL iMST SATA software RAID Configuration Utility program: Use the INTEL iMST SATA software
RAID Configuration Utility program to configure the onboard SATA controller with software RAID
capabilities and the devices that are attached to it. For information about using this program, see
• ThinkServer 8708ELP SAS RAID, ThinkServer 8708EM2 SAS RAID, or ThinkServer RAID 700
Configuration Utility program: Use the Configuration Utility program to configure the ThinkServer
8708ELP SAS RAID, ThinkServer 8708EM2 SAS RAID, or ThinkServer RAID 700 adapter with RAID
capabilities and the devices that are attached to it. For information about using this program, see the
MegaRAID SAS Software User Guide on the documentation DVD that came with you server.
The following table lists the different server configurations and the applications that are available for
configuring and managing RAID arrays.
Table 12. Server configurations and applications for configuring and managing RAID arrays
RAID array configuration (before
operating system is installed)
RAID array management (after
operating system is installed)
Server configuration
INTEL iMST SATA software RAID
INTEL iMST Configuration Utility
program (press Ctrl+I to start)
INTEL RAID Storage Manager
(WebConsole)
ThinkServer 8708ELP SAS RAID
Adapter
LSI MegaRAID WebBIOS
Configuration Utility (press Ctrl+H to
start)
MegaRAID Storage Manager (MSM)
MegaRAID Storage Manager (MSM)
MegaRAID Storage Manager (MSM)
ThinkServer 8708EM2 RAID Adapter
ThinkServer RAID 700 Adapter
LSI MegaRAID WebBIOS
Configuration Utility (press Ctrl+H to
start)
LSI MegaRAID WebBIOS
Configuration Utility (press Ctrl+H to
start)
Using the Setup Utility program
Use the Setup Utility program to perform the following tasks:
• View configuration information
• View and change assignments for devices and I/O ports
• Set the date and time
• Set the startup characteristics of the server and the order of startup devices
• Set and change settings for advanced hardware features
• View, set, and change settings for power-management features
• View and clear error logs
© Copyright Lenovo 2010, 2011
67
Download from Www.Somanuals.com. All Manuals Search And Download.
• Resolve configuration conflicts
Starting the Setup Utility program
To start the Setup Utility program, do the following:
1. Approximately three minutes after the server is connected to a working electrical outlet, the power
button becomes active. Turn on the server and the POST runs automatically. You will then see the logo
screen. The POST is a set of tests and procedures that are performed each time you turn on your server.
2. Press Del as soon as you see the logo screen. The Setup Utility program opens. If you have set an
administrator password, you must type the administrator password to access the full Setup Utility
program menu. If you do not type the correct administrator password, a limited Setup Utility program
menu is available.
Note: You can also press TAB as soon as you see the logo screen to review the POST process and
information.
3. The Setup Utility program menu lists various items about the system configuration settings. Select the
settings to view or change.
When working with the Setup Utility program, you must use the keyboard. The keys used to perform various
tasks are displayed at the bottom of each screen.
Note: Use the default setting for any item you are not familiar with. Do not change the value of unfamiliar
items or items that are not mentioned in this manual to avoid any unexpected problems. If you cannot turn
on the server because of incorrect BIOS settings, refer to and use the jumpers to clear CMOS and recover
to the factory default settings.
Introduction of the BIOS items
The following tables list all the main menus and items in the Setup Utility program. Some items might vary
because of the BIOS updates.
Notes:
1. Use the default setting for any item you are not familiar with. Do not change the value of unfamiliar
items or items that are not mentioned in this manual to avoid any unexpected problems. If you cannot
turn on the server because of incorrect BIOS settings, use the jumpers on the system board to clear
CMOS and recover to the factory default settings.
2. After updating the BIOS, all the BIOS settings become the default settings of the updated BIOS version.
You need to check and reconfigure the BIOS settings for your specific needs.
Table 13. The Setup Utility program main menu
Item
Description
Set the basic BIOS parameters.
Main
Advanced
PCIPnP
Boot
Set the advanced BIOS parameters.
Set the PCI parameters.
Set the boot parameters.
Set the security parameters.
Set the chipset.
Security
Chipset
Exit
Exit the Setup Utility program.
68 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 14. Items under the Main menu
Item
Option
Description
AMIBIOS
View the BIOS version and creation
date information.
Processor
View microprocessor information.
View memory capacity information.
Set system time.
System Memory
System Time
System Date
HH:MM:SS
MM/DD/YYYY
Set system date.
Table 15. Items under the Advanced menu
Item
Description
CPU Configuration
Enter the submenu to see all the options. See Submenus
Mass Storage Controller Configuration
SuperIO Configuration
Enter the submenu to see all the options. See Submenus
Enter the submenu to see all the options. See Submenus
USB Configuration
Enter the submenu to see all the options. See Submenus
Hardware Health Configuration
IPMI 2.0 Configuration
Enter the submenu to see all the options. See Submenus
Enter the submenu to see all the options. See Submenus
Intel VT-d Configuration
Remote Access Configuration
System Information
Enter the submenu to see all the options. See Submenu
Enter the submenu to see all the options. See Submenus
View the system information, including the machine type
and model, serial number, asset tag, and UUID.
Note: Do not change any unfamiliar item value under the Advanced menu.
Table 16. Submenus under the CPU Configuration
Item
Option
Disabled / [Enabled]
Description
C1E Support
Enable or disable the C1E function
of the microprocessor. This setting
might impact system performance.
Hardware Prefetcher
Disabled / [Enabled]
Enable or disable the prefetch
function of the microprocessor.
This setting might impact system
performance.
Enable or disable the adjacent cache
line prefetch. This setting might
impact system performance.
Adjacent Cache Line Prefetch
MPS and ACPI MADT ordering
Disabled / [Enabled]
Legacy ordering / [Modern ordering]
Select the MPS and ACPI MADT
ordering method.
Chapter 6. Configuring the server 69
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 16. Submenus under the CPU Configuration (continued)
Item
Option
Disabled / [Enabled]
Description
Enable or disable the Intel
Intel® Virtualization Tech
Virtualization Tech. This technology
can provide additional capacity for
hardware computing. If you set this
feature to Enabled, you have to turn
off the server and disconnect the
power cord from electrical outlet, and
then reconnect the power cord and
turn on the server to make this feature
take effect.
Enabling the Execute-Disable Bit
Capability can prevent the executive
code of some malicious software
from using the data page.
Execute-Disable Bit Capability
Intel® HT Technology
Disabled / [Enabled]
[Enabled] / Disabled
Enable or disable the hyper-thread
technology. (Whether your server
supports this feature or not is
depending on the type of the installed
microprocessor.)
Enable or disable the multi-core
processing function.
Active Processor Cores
Intel® SpeedStep™ tech
Intel® TurboMode tech
Intel® C-STATE tech
C3 State
[All] / 1 / 2
Disabled / [Enabled]
Disabled / [Enabled]
Disabled / [Enabled]
Disabled / [ACPI C2] / ACPI C3
Disabled / [Enabled]
Enable or disable the SpeedStep
technology.
Enable or disable the Turbo Mode
technology.
Enable or disable the C-STATE
technology.
Set the microprocessor C3 state
mode.
C6 State
Enable or disable the C6 state of the
microprocessor.
C State package limit setting
C1 Auto Demotion
[Auto] / C1 / C3 / C6 / C7
Disabled / [Enabled]
Set the C state package limit.
Enable or disable the C1 State
Demotion of the microprocessor.
C3 Auto Demotion
ACPI T State
Notes:
Disabled / [Enabled]
Disabled / [Enabled]
Enable or disable the C3 State
Demotion of the microprocessor.
Enable or disable the microprocessor
throttling in ACPI.
1. The settings in [ ] are the default settings in the Setup Utility program.
2. The above options might vary depending on the type of the installed microprocessor.
70 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 17. Submenus under the Mass Storage Controller Configuration
Item Option
SATA Configuration Disabled / [Enabled]
Description
Enable or disable the integrated SATA
controller.
To select the hard disk drive mode.
If this option is set to IDE, all the
SATA connectors will be configured
as stand-alone SATA connectors.
Configure SATA as
[IDE] / RAID
Notes:
1. The settings in [ ] are the default settings in the Setup Utility program.
2. The SATA Configuration item might not apply because your server came with an integrated SAS controller.
Table 18. Submenus under the SuperIO Configuration
Item
Option
Description
Serial Port1 Address
Disabled / [3F8/IRQ4] / 3E8/IRQ4 /
2E8/IRQ3
Select the I/O base address and
interrupt for serial port 1.
Serial Port2 Address
Disabled / [2F8/IRQ3] / 3E8/IRQ4 /
2E8/IRQ3
Select the I/O base address and
interrupt for serial port 2.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 19. Submenus under the USB Configuration
Item
Option
Description
Enable or disable the support on
legacy USB devices.
Legacy USB Support
Disabled / [Enabled] / Auto
USB 2.0 Controller Mode
Hotplug USB FDD Support
FullSpeed / [HiSpeed]
Select the USB speed.
Enable or disable the support on the
hot-swap USB diskette drive.
Disabled / Enabled / [Auto]
Note: The settings in [ ] are the default settings in the Setup Utility program.
For external USB devices, the USB Mass Storage Device Configuration submenu is as below:
Emulation Type
[Auto] / Floppy / Forced FDD / Hard
Disk / CDROM
Select the type of the USB device.
Table 20. Submenus under the Hardware Health Configuration
Item
Option
Description
Items and options with BMC configuration:
Auto Fan Control
Disabled / [Enabled]
If this option is set to Disabled, the
fan runs at the full speed; if this option
is set to Enabled, the fan speed is
controlled by the system temperature.
PWM Minimal Duty Cycle
[60% Duty Cycle] / 45% Duty Cycle
/ 30% Duty Cycle
Select the PWM Minimal Duty Cycle
for the fan: 60%-100%, 45%-100%,
or 30%-100%.
Sensor Data Register Monitoring
Read Only
The sensor data in this option is for
read only. The detected data includes
the temperature, voltage and fan
speed.
Items and options without BMC configuration:
Chapter 6. Configuring the server 71
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 20. Submenus under the Hardware Health Configuration (continued)
Item
Option
Disabled / [Enabled]
Description
Enable or disable the hardware
monitor function.
H/W Health Function
Auto FAN Control
Disabled / [Enabled]
If this option is set to Disabled, the
fan runs at the full speed; if this option
is set to Enabled, the fan speed is
controlled by the system temperature.
PWM Minimal Duty Cycle
Fan Failure LED Indication
[60% Duty Cycle] / 45% Duty Cycle
/ 30% Duty Cycle
Select the PWM Minimal Duty Cycle
for the fan: 60%-100%, 45%-100%,
or 30%-100%.
Disabled / [Enabled]
Enable or disable the fan alarm
function. If this option is set to
Enabled, a message about fan failure
will be displayed on the POST screen
when the rotational speed of each fan
is less than 800 rpm.
Hardware Health Event Monitoring
The sensor data in this option is for
read only. The detected data includes
the temperature and system fan
rotational speed.
Read Only
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 21. Submenus under the IPMI 2.0 Configuration
Item
Sub-item
Option
Description
View the system event log.
View BMC System Event
Log
Delete the system event
log.
Clear BMC System Event
Log
Set LAN Configuration
Set the IP address source,
IP address, subnet mask,
and gateway address.
Enable or disable the PEF
support.
Set PEF Configuration
PEF SUPPORT
Disabled / [Enabled]
BMC Watch Dog Timer
Action
[Disabled] / Reset System / Disable or enable the OS
Power Down / Power Cycle based dongle. If enabled,
whenever any problems
arising from the operation
system, such as the
system halted, the system
management feature will
take actions of Reset
System, Power Down, or
Power Cycle at the prompt
of the dongle Timer.
BMC Alert LED and Beep
FW key
[Off] / On
[0000000]
Turn on or turn off the BMC
alert LED and beep.
Note: The settings in [ ] are the default settings in the Setup Utility program.
72 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 22. Submenu under the Intel VT-d Configuration
Item
Option
Disabled / [Enabled]
Description
Intel VT-d
Enable or disable the virtualization
technology for I/O devices.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 23. Submenus under the Remote Access Configuration
Item
Option
[Disabled] / Enabled
Description
Remote Access
Enable or disable the serial port
remote access.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 24. Items under the PCIPnP menu
Item
Option
Description
Clear NVRAM
[No] / Yes
If this option is set to Yes, that means
to clear the NVRAM information when
the system starts up.
Boots Graphic Adapter Priority
[Auto] / Onboard VGA
If this option is set to Auto, the
external graphics card will be enabled
firstly. If no external graphics card,
the integrated graphics controller is
automatically enabled. If this option
is set to Onboard VGA, only the
integrated graphics card is enabled.
LAN1
The Auto option means to
[Auto] / Enabled / Disabled
automatically enable the integrated
Ethernet controller 1. The Enabled
option means to enable the integrated
Ethernet controller 1. The Disabled
option means to disable the integrated
Ethernet controller 1.
LAN1 OP-ROM
LAN2
[Enabled] / Disabled
Enable or disable the wake-up from
LAN 1.
The Auto option means to
[Auto] / Enabled / Disabled
automatically enable the integrated
Ethernet controller 2. The Enabled
option means to enable the integrated
Ethernet controller 2. The Disabled
option means to disable the integrated
Ethernet controller 2.
LAN2 OP-ROM
[Enabled] / Disabled
Enable or disable the wake-up from
LAN 2.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Chapter 6. Configuring the server 73
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 25. Items under the Boot menu
Item
Sub-item
Option
Description
Enable or disable the quick
boot feature.
Boot Settings Configuration Quick Boot
[Disabled] / Enabled
Enable or disable the
feature to show OEM Logo
during the POST.
Quiet Boot
[Enabled] / Disabled
AddOn ROM / Display
Mode
[Force BIOS] / Keep Current Set the AddOn ROM
Display Mode.
Bootup Num-Lock
[Off] / On
Set the Num-Lock LED
state.
Boot Device Priority
1st Boot Device
2nd Boot Device
Boot device names
Boot device names
Set the startup device
sequence (support at most
five startup devices).
Hard Disk Drives
CD/DVD Drives
Based on the installed hard
disk drives.
1st Drive / 2nd Drive...
1st Drive...
Based on the installed
optical drives.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 26. Items under the Security menu
Item
Description
Change Supervisor Password
Change User Password
Set or change the supervisor password. The password
can be any combination of up to 6 (1 to 6) alphabetic and
numeric characters.
Set or change the user password. The password can
be any combination of up to 6 (1 to 6) alphabetic and
numeric characters.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 27. Items under the Chipset menu
Item
Sub-item
QPI Frequency
Option
Description
CPU Bridge Configuration
[Auto] / 4.800GT / 5.866GT Standard transferring rate
/ 6.400GT
of the QPI bus.
QPI L0s and L1
Disabled / [Enabled]
Enable or disable the QPI
L0s and L1.
Memory Frequency
[Auto] / Force DDR-800 /
Force DDR-1066 / Force
DDR-1333
Set the frequency of the
memory module. Make
sure that the mandatory
memory frequency setting
is less than the maximum
frequency that the memory
module can support.
Memory Mode
[Independent] / Channel
Mirroring / Lockstep
Set the memory channel
mode to improve reliability
or efficiency.
74 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 27. Items under the Chipset menu (continued)
Item Sub-item
Option
Description
South Bridge Configuration Restore on AC Power Loss Power Off / Power On /
[Last State]
If the power is recovered
after outage, the system
will be at the state that you
set under Restore on AC
Power Loss.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Exiting the Setup Utility program
After you finish viewing or changing settings, press Esc to return to the Setup Utility program main menu.
You might have to press Esc several times. Then, you can do one of the following:
• If you want to save the new settings and exit the Setup Utility program, press F10. Otherwise, your
changes will not be saved.
• If you do not want to save the new settings, select Exit ➙ Discard Changes and Exit.
• If you want to return to the default settings, press F9 or select Exit ➙ Load Optimal Defaults.
Using passwords
By using the Setup Utility program, you can set a password to prevent unauthorized access to your server
and data. The following options are available to help you set a supervisor password or a user password:
• Change Supervisor Password
• Change User Password
You do not have to set a password to use your server. However, using a password improves computing
security. If you decide to set a password, read the following sections.
Password considerations
A password can be any combination of up to 6 (1 to 6) alphabetic and numeric characters. For security
reasons, it is recommended to use a strong password that cannot be easily compromised. To set a strong
password, use the following guidelines:
Note: The Setup Utility program passwords are not case sensitive.
• Have six characters in length
• Contain at least one alphabetic character and one numeric character
• Not be your name or your user name
• Not be a common word or a common name
• Be significantly different from your previous passwords
Setting, changing, or deleting a password
This section provides instructions on how to set, change, or delete a password.
To set, change, or delete a password, do the following:
2. From the Setup Utility program main menu, select Security ➙ Change Supervisor Password or
Change User Password. For information about the supervisor password and user password, see
3. Follow the instructions on the screen to set, change, or delete a password.
Chapter 6. Configuring the server 75
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: A password can be any combination of up to 6 (1 to 6) alphabetic and numeric characters. For
RAID controllers
The following table lists the various utilities available to configure RAID controllers before an operating
system is installed.
Table 28. RAID utilities
Where to find more
Utility
Description
Location
information
• For use with all
factory-supported RAID
controllers
EasyStartup RAID
configuration utility
EasyStartup DVD
“Using the ThinkServer
EasyStartup program” on
page 76
• Automatically detects
hardware and lists
all supported RAID
configurations
• Configures one disk
array per controller
using all drives currently
attached to the controller
• Created a RAID response
file that can be used
to configure RAID
controllers on similarly
configured Lenovo
servers.
INTEL iMST SATA software INTEL iMST SATA software Press Ctrl+I to start
“Configuring the onboard
page 79
RAID Configuration Utility
program
RAID
LSI MegaRAID WebBIOS
Configuration Utility
ThinkServer 8708ELP SAS
RAID Adapter, ThinkServer
8708EM2 RAID Adapter,
or ThinkServer RAID 700
Adapter (9260-8i)
Press Ctrl+H to start
Refer to the MegaRAID
SAS Software User Guide
on the documentation DVD
that came with you server.
And you can find and install
the MegaCLI program and
the MegaRAID Storage
Manager program in the
ThinkServer EasyStartup
DVD that came with your
server. Insert the DVD into
the optical drive and the
files are in the \Tools And
Utilities directory.
Using the ThinkServer EasyStartup program
The ThinkServer EasyStartup DVD simplifies the process of configuring your RAID controllers and installing
an operating system. The program works in conjunction with your Windows or Linux operating-system
installation disc to automate the process of installing the operating systems and associated device drivers.
If you did not receive an ThinkServer EasyStartup DVD with your server, you can download an image from
76 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The EasyStartup program has the following features:
• Self-booting DVD
• Easy-to-use, language-selectable interface
• Integrated help system
• Automatic hardware detection
• RAID configuration utility
• Device drivers provided based on the server model and detected devices
• Selectable partition size and file system
• Support for multiple operating systems
• Installs the operating system and device drivers in an unattended mode to save time
• Creates a reuseable response file that can be used with similarly configured Lenovo servers to make
future installations even faster.
Before you use the EasyStartup DVD
Functionality and supported operating systems can vary with different versions of the EasyStartup program.
To learn more about the version you have, do the following:
1. Insert the ThinkServer EasyStartup DVD and restart the server.
2. Advance to the Home screen.
3. Click Compatability notes. The compatability notes feature provides detailed information about the
RAID controllers, operating systems, and server configurations supported by that version of the
EasyStartup program.
4. Click User Guide. The User Guide provides an overview of the various functions provided by that
version of the EasyStartup program.
Before using the EasyStartup program to install an operating system, make sure any external storage
devices and fiber channels are configured correctly.
Setup and configuration
When you start the ThinkServer EasyStartup DVD, you will be prompted for the following:
• Select the language in which you want to view the program.
• Select the language of the keyboard you will be using with the program.
Note: The following language keyboards are supported: English, French, German, Spanish, Japanese,
Turkish, Italian, and Dutch. Your ThinkServer EasyStartup DVD might be English only. In this case, the
keyboard layout should be English.
You will then see one or more reminders about configuring storage devices, and then you will be presented
with the Lenovo License Agreement. Read the license agreement carefully. You must agree with terms in
order to continue.
After agreeing to the license agreement, you will be given the following choices:
• Continue to the main program interface
• Use a shortcut to install an operating system based a response file that you previously created using the
EasyStartup program
• Use a shortcut to configure RAID controllers based on a RAID response file that you previously created
using the EasyStartup program
Chapter 6. Configuring the server 77
Download from Www.Somanuals.com. All Manuals Search And Download.
If you continue to the main program interface, you will have the following selectable options:
• Compatibility notes: This selection provides information about the RAID controllers, operating systems,
and server configurations supported by that version of the EasyStartup program.
• User Guide: This selection provides information about the features provided by that version of the
EasyStartup program.
• Hardware list: This selection displays a list of hardware devices detected by the EasyStartup program.
• Configure RAID: This selection enables you to view the current RAID configuration for each installed
RAID controller and make changes if needed.
• Install operating system: This selection displays a series of choices and prompts to collect information
required for installation, prepares the hard disk for installation, and then initiates the installation process
using the user-provided operating-system installation CD or DVD.
• About: This selection displays version information and legal notices.
Configuring RAID
The RAID configuration feature that is part of the EasyStartup program enables you to view and change RAID
settings for supported RAID controllers. Through this feature, you have the ability to configure each installed
controller. The program automatically detects the number of discs currently attached to the controller,
determines the possible RAID configurations that can be configured, and prompts you through the steps
to configure one or more disk arrays with or without hot-spare hard disk drives. As you configure each
controller you will be given the option to save the RAID configuration settings to a RAID response file, which
you can use on other similarly configured Lenovo servers. This method satisfies most users' needs.
Typical operating system installation
When you select Install operating system, you will be prompted for information required for the installation.
The prompts vary depending on the operating system selected. This section describes the tasks associated
with a typical Windows operating system installation. Each task must be completed in order before moving
to the next task.
Note: Ensure that your RAID controller is correctly configured before you select an operating system to install.
• Select operating system: This task enables you to select the operating system that you will be installing.
• Select disk: This task enables you to select the disk where you want to install the operating system.
Note: The disk that you select must be set as the boot disk in the Setup Utility program.
• Partitions options: This task enables you to choose whether you want to repartition the selected drive
or use an existing partition.
• Partition settings: This task enables you to choose the file system type and define the partition size.
• Installation settings: This task prompts you for user and system settings, the operating system product
key, and the administrator password.
• Network settings: This task prompts you for domain and workgroup settings, Ethernet controller type, IP
address settings, DNS settings, and WINS address settings.
• Install applications: This task enables you to run custom commands or scripts at the end of the
installation process and install the ThinkServer EasyManage program to help you manage your servers.
• Install Windows components: This task enables you to install optional Windows components such
as IIS, ASP.NET, and SNMP.
• Confirm settings: This task enables you to review all of the information you provided.
• Save response file: This task gives you the option of saving the information on a diskette or USB device
as a response file for future installations on similarly configured Lenovo servers.
78 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
• Start installation: This task starts the actual installation process. First, the disk is prepared using the disk
and partition information you specified. Then you are prompted to insert the operating system disk, and
the operating system is installed using the information that you specified.
Configuring the onboard SATA software RAID
This chapter provides instructions on how to configure the onboard SATA software RAID by using the
INTEL iMST Configuration Utility program.
RAID information
During system startup, the SATA RAID BIOS is initialized and the BIOS version of the RAID adapter, the
current RAID status, and the configuration of the array will be displayed on the screen. The status of the
array will be one of the following:
1. Normal: This status indicates the normal operation of the RAID array.
2. Degraded: This status indicates that more than one hard disk drive is faulty or disconnected from
mirror volume and you have to replace the faulty hard disk drives and recover the data through the
Rebuild function.
3. Failed: This status indicates that the RAID array is failed and unable to be restored by rebuilding. You
have to create the array again.
4. Rebuild: This status indicates that the array is being rebuilt.
Starting the Intel Matrix Storage Manager program
To start the Intel Matrix Storage Manager program, do the following:
1. During the POST, when you see the message “Press Ctrl-I to enter Configuration Utility...”, press Ctrl+I.
The Intel Matrix Storage Manager program main menu opens.
2. Follow the instructions on the screen to configure the SATA RAID. When working with this program,
you must use the keyboard. The keys used to perform various tasks are displayed at the bottom
of each screen.
The main menu of the Intel Matrix Storage Manager program includes the following items:
• Create RAID volume is for creating the RAID volume.
• Delete RAID volume is for deleting the RAID volume.
• Reset Disks to Non-RAID is for setting the hard disk drives to non RAID.
• Recovery Volume Options is a recovery option when the RAID mode is Recovery.
• Exit is for exiting the program.
Creating the RAID volume
This section provides instructions on how to create the RAID volume by using the Intel Matrix Storage
Manager program.
To create the RAID volume by using the Intel Matrix Storage Manager program, do the following:
1. Select Create RAID Volume from the Intel Matrix Storage Manager program main menu and press
Enter. The CREATE VOLUME MENU opens.
2. Follow the instructions on the screen to set the volume name and RAID level, select hard disk drives, the
strip size (RAID 1 cannot be striped), and the capacity.
Note: Do not exceed the maximum capacity.
Chapter 6. Configuring the server 79
Download from Www.Somanuals.com. All Manuals Search And Download.
3. When finish all the settings, press Enter. A warning message will be displayed. Press Y to confirm
your settings and create the volume.
Deleting the RAID volume
This section provides instructions on how to delete the RAID volume by using the Intel Matrix Storage
Manager program.
To delete the RAID volume by using the Intel Matrix Storage Manager program, do the following:
1. Select Delete RAID Volume from the Intel Matrix Storage Manager program main menu and press Enter.
The DELETE VOLUME MENU opens.
2. Follow the instructions on the screen to select the RAID volume and press Del.
3. Press Y when prompted to delete the RAID volume.
Rebuilding the RAID volume
When there is a failing hard disk drive in the volume, you need to replace the hard disk drive. Then, the
volume will be automatically rebuilt. The rebuilding will be performed in the operation system.
Configuring the Gigabit Ethernet controller
The Ethernet controllers are integrated on the system board. They provides an interface for connecting
to a 10 Mbps, 100 Mbps, or 1 Gbps network and provides full-duplex (FDX) capability, which enables
simultaneous transmission and reception of data on the network. If the Ethernet ports in the server supports
auto-negotiation, the controllers detect the data-transfer rate (10BASE-T, 100BASE-TX, or 1000BASE-T) and
duplex mode (full-duplex or half-duplex) of the network and automatically operates at that rate and mode.
You do not have to set any jumpers or configure the controllers. However, you must install a device driver to
enable the operating system to address the controllers.
Updating the firmware
The firmware in the server is periodically updated and is available for download on the Lenovo Support Web
site. Go to http://www.lenovo.com/support to check for the latest level of firmware, such as the BIOS
ROM file, BMC FW and RAID FW files.
When you replace a device in the server, you might have to either update the server with the latest version of
the firmware that is stored in memory on the device or restore the pre-existing firmware from a diskette or
CD image.
• The BIOS ROM file is stored in flash on the system board.
• The Ethernet firmware is stored in EEPROM on the Ethernet controller.
• The onboard SATA software RAID firmware is integrated into the BIOS ROM on the system board.
• The SAS RAID card firmware is stored in ROM on the SAS RAID card.
Using the EasyUpdate Firmware Updater program
ThinkServer EasyUpdate Firmware Updater is a software application that enables you to maintain your
system firmware up to date and helps you avoid unnecessary outages. Firmware Updater updates the server
system and adapter firmware.
80 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
To update your system, do the following:
2. Click Download & Drivers ➙ ThinkServer and then follow the instructions on the Web page to
download the ISO image for the EasyUpdate Firmware Updater program.
3. Burn the ISO image to a disc.
4. Set the optical drive as the first boot device and insert the disc into the optical drive. The server will
proceed directly to the User Interface Application’s introductory screen.
5. Read the messages and instructions displayed on the introductory screen. Then, click Next to proceed
to the list of firmware updates available on the optical media.
6. Click Apply to begin the updates (click Cancel if you want to abort the updates and exit). All updates
will run to completion, with each updater’s native user interface kept visible to the user. When the User
Interface Application regains control, you will see the results screen.
Before distributing the firmware update to other servers, ensure that your server can restart successfully
without encountering hardware problems.
Installing the ThinkServer EasyManage program
To install the ThinkServer EasyManage Agent, you must already have a core server running the ThinkServer
EasyManage Core Server program. The ThinkServer EasyManage Agent must be installed from that core
server. Refer to the ThinkServer EasyManage Core Server documentation about Agent deployment for
instructions on the various ways to deploy the ThinkServer EasyManage Agent to your new server.
Also, the ThinkServer EasyStartup program provides an option to install the ThinkServer EasyManage Agent
as part of the operating system installation process.
Chapter 6. Configuring the server 81
Download from Www.Somanuals.com. All Manuals Search And Download.
82 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7. Troubleshooting
This chapter describes the diagnostic tools that are available to help you solve problems that might occur in
the server.
If you cannot diagnose and correct a problem by using the information in this chapter, see Appendix B
Troubleshooting tables
Use the troubleshooting tables to find solutions to problems that have identifiable symptoms.
If you have just added new software or a new optional device and the server is not working, complete the
following steps before you use the troubleshooting tables:
1. Check the operator information panel.
2. Remove the software or device that you just added.
3. Reinstall the new software or new device.
DVD drive problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
The DVD drive is not
recognized.
1. Make sure that:
• The SATA channel to which the DVD drive is attached (primary or secondary)
is enabled in the Setup Utility program.
• All cables and jumpers are installed correctly.
• The signal cable and connector are not damaged and the connector pins
are not bent.
• The correct device driver is installed for the DVD drive.
2. Reseat the following components:
a. DVD drive
b. DVD drive cables
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. DVD drive
b. DVD drive and cables
c. (Trained service technician only) System board
A DVD is not working correctly.
© Copyright Lenovo 2010, 2011
1. Clean the DVD.
2. Reseat the DVD drive.
3. Replace the DVD drive.
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
The DVD drive tray is not
working.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release opening.
3. Reseat the DVD drive.
4. Replace the DVD drive.
General problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
A cover lock is broken, an LED
is not working, or a similar
problem has occurred.
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a
trained service technician.
Hard disk drive problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
Not all drives are recognized by Remove the drive that is indicated by the diagnostic tests; then, run the hard disk
the hard disk drive diagnostic
tests.
drive diagnostic tests again. If the remaining drives are recognized, replace the
drive that you removed with a new one.
The server stops responding
during the hard disk drive
diagnostic test.
Remove the hard disk drive that was being tested when the server stopped
responding, and run the diagnostic test again. If the hard disk drive diagnostic test
runs successfully, replace the drive that you removed with a new one.
A hard disk drive was not
detected while the operating
system was being started.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic
tests again.
Intermittent problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
84 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
A problem occurs only
occasionally and is difficult to
diagnose.
1. Make sure that:
• All cables and cords are connected securely to the rear of the server and
attached devices.
• When the server is turned on, air is flowing from the fan grille. If there is
no airflow, the fan is not working. This can cause the server to overheat
and shut down.
Keyboard, mouse, or pointing-device problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
All or some keys on the
keyboard do not work.
1. Make sure that:
• The keyboard cable is securely connected.
• The server and the monitor are turned on.
2. The keyboard is compatible with the server. Refer to the Web site at
3. If you are using a USB keyboard and it is connected to a USB hub, disconnect
the keyboard from the hub and connect it directly to the server.
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Keyboard
b. (Trained service technician only) System board
1. Make sure that:
The mouse or pointing device
does not work.
• The mouse or pointing device is compatible with the server. Refer to the Web
• The mouse or pointing-device cable is securely connected to the server.
• The mouse or pointing-device device drivers are installed correctly.
• The server and the monitor are turned on.
• The mouse is enabled in the Setup Utility program.
2. If you are using a USB mouse or pointing device and it is connected to a USB
hub, disconnect the mouse or pointing device from the hub and connect it
directly to the server.
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Mouse or pointing device
b. (Trained service technician only) System board
Memory problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
Chapter 7. Troubleshooting 85
Download from Www.Somanuals.com. All Manuals Search And Download.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
The amount of system memory
that is displayed is less than
the amount of installed physical
memory.
1. Make sure that:
• No error LEDs are lit on the operator information panel or on the DIMM.
• Memory mirroring does not account for the discrepancy.
• The memory modules are seated correctly.
• You have installed the correct type of memory.
• If you changed the memory, you updated the memory configuration in the
Setup Utility program.
• All banks of memory are enabled. The server might have automatically
disabled a memory bank when it detected a problem, or a memory bank
might have been manually disabled.
2. Check the POST event log for DIMM error messages:
• If a DIMM was disabled by a systems-management interrupt (SMI), replace
the DIMM.
• If a DIMM was disabled by the user or by POST, run the Setup Utility program
and enable the DIMM.
3. Make sure that there is no memory mismatch when the server is at the minimum
memory configuration.
4. Add one pair of DIMMs at a time, making sure that the DIMMs in each pair
are matching.
5. Reseat the DIMMs.
6. Replace the DIMMs one at a time in the order and restart the server each time.
1. Reseat the DIMMs; then, restart the server.
Multiple rows of DIMMs in a
branch are identified as failing.
2. Replace the lowest-numbered DIMMs with identical known good DIMMs;
then, restart the server. Repeat as necessary. If the failures continue after all
identified pairs are replaced, contact a trained service technician for help.
3. Return the removed DIMMs, one pair at a time, to their original connectors,
restarting the server after each pair, until a pair fails. Replace each DIMM in
the failed pair with an identical known good DIMM, restarting the server after
you reinstall each DIMM. Replace the failed DIMM. Repeat these actions until
you have tested all removed DIMMs.
4. (Trained service technician only) Replace the system board.
Microprocessor problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
86 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
The server emits a continuous
beep during the POST,
indicating that the startup
(boot) microprocessor is not
working correctly.
1. Make sure that the server supports all the microprocessors and that the
microprocessors match in speed and cache size.
2. (Trained service technician only) Reseat microprocessor 1.
3. (Trained service technician only) If there is no indication of which microprocessor
has failed, isolate the error by testing with one microprocessor at a time.
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. (Trained service technician only) Microprocessor 2
b. VRM 2
c. (Trained service technician only) System board
5. (Trained service technician only) If multiple error codes indicate a microprocessor
error, reverse the locations of two microprocessors to determine whether the
error is associated with a microprocessor or with a microprocessor socket.
• If the error is associated with a microprocessor, replace the microprocessor.
• If the error is associated with a VRM, replace the VRM.
• If the error is associated with a microprocessor socket, replace the system
board.
Monitor problems
Some monitors have their own self-tests. If you suspect a problem with your monitor, see the documentation
that comes with the monitor for instructions for testing and adjusting the monitor.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
Testing the monitor
1. Make sure that the monitor cables are firmly connected.
2. Try using a different monitor on the server, or try using the monitor that is being
tested on a different server.
3. Run the diagnostic programs. If the monitor passes the diagnostic programs,
the problem might be a video device driver.
4. (Trained service technician only) Replace the system board.
The screen is blank.
1. If the server is attached to a KVM switch, bypass the KVM switch to eliminate it
as a possible cause of the problem: connect the monitor cable directly to the
correct connector on the rear of the server.
2. Make sure that:
• The server is turned on. If there is no power to the server, see “Power
• The monitor cables are connected correctly.
• The monitor is turned on and the brightness and contrast controls are
adjusted correctly.
• No POST errors are generated when the server is turned on.
3. Make sure that the correct server is controlling the monitor, if applicable.
Chapter 7. Troubleshooting 87
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
The monitor has screen
jitter, or the screen image is
wavy, unreadable, rolling, or
distorted.
1. If the monitor self-tests show that the monitor is working correctly, consider
the location of the monitor. Magnetic fields around other devices (such as
transformers, appliances, fluorescent lights, and other monitors) can cause
screen jitter or wavy, unreadable, rolling, or distorted screen images. If this
happens, turn off the monitor.
Attention: Moving a color monitor while it is turned on might cause screen
discoloration.
Move the device and the monitor at least 305 mm (12 inches) apart, and turn on
the monitor.
To prevent diskette drive read/write errors, make sure that the distance between
the monitor and any external diskette drive is at least 76 mm (3 inches).
2. Reseat the monitor.
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Monitor
b. (Trained service technician only) System board
Wrong characters appear on
the screen.
1. If the wrong language is displayed, update the server firmware with the correct
2. Reseat the monitor.
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Monitor
b. (Trained service technician only) System board
Optional-device problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
A Lenovo optional device that
was just installed does not
work.
1. Make sure that:
• The device is designed for the server. For a list of the supported options for
systems page, click Products ➙ Options.
• You followed the installation instructions that came with the device and the
device is installed correctly.
• You have not loosened any other installed devices or cables.
• You updated the configuration information in the Setup Utility program.
Whenever memory or any other device is changed, you must update the
configuration.
2. Reseat the device that you just installed.
3. Replace the device that you just installed.
88 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
A Lenovo optional device that
used to work does not work
now.
1. Make sure that all of the hardware and cable connections for the device are
secure.
2. If the device comes with test instructions, use those instructions to test the
device.
3. If the failing device is an SCSI device, make sure that:
• The cables for all external SCSI devices are connected correctly.
• The last device in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
• Any external SCSI device is turned on. You must turn on an external SCSI
device before you turn on the server.
4. Reseat the failing device.
5. Replace the failing device.
Power problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Chapter 7. Troubleshooting 89
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
The power-control button does
not work (the server does not
start).
Note: The power-control
button will not function until
3 minutes after the server has
been connected to ac power.
1. Make sure that the power-control button is working correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained service technician only) Reseat the operator information panel
cables, and then repeat the above two steps. If the server starts, reseat the
operator information panel. If the problem remains, replace the operator
information panel.
2. Make sure that:
• The power cords are correctly connected to the server and to a working
electrical outlet.
• The type of memory that is installed is correct.
• The DIMM is fully seated.
• The LEDs on the power supply do not indicate a problem.
• The microprocessors are installed in the correct sequence.
3. Reseat the following components:
a. DIMMs
b. (Trained service technician only) Power switch connector
c. (Trained service technician only) Power backplane
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. DIMMs
b. (Trained service technician only) Power switch connector
c. (Trained service technician only) Power backplane
d. (Trained service technician only) System board
5. If you just installed an optional device, remove it, and restart the server. If
the server now starts, you might have installed more devices than the power
supply supports.
The server does not turn off.
1. Determine whether you are using an Advanced Configuration and Power
Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, do the following:
a. Press Ctrl+Alt+Delete.
b. Turn off the server by pressing the power-control button for 5 seconds.
c. Restart the server.
d. If the server fails the POST and the power-control button does not work,
disconnect the power cord for 20 seconds; then, reconnect the power cord
and restart the server.
2. If the problem remains or if you are using an ACPI-aware operating system,
suspect the system board.
The server unexpectedly shuts
down, and the LEDs on the
operator information panel are
not lit.
Serial port problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
90 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
The number of serial ports that
are identified by the operating
system is less than the number
of installed serial ports.
1. Make sure that:
• Each port is assigned a unique address in the Setup Utility program and
none of the serial ports is disabled.
• The serial port adapter (if one is present) is seated correctly.
2. Reseat the serial port adapter.
3. Replace the serial port adapter.
A serial device does not work.
1. Make sure that:
• The device is compatible with the server.
• The serial port is enabled and is assigned a unique address.
• The device is connected to the correct connector.
2. Reseat the following components:
a. Failing serial device
b. Serial cable
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Failing serial device
b. Serial cable
c. (Trained service technician only) System board
Software problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
You suspect a software
problem.
1. To determine whether the problem is caused by the software, make sure that:
• The server has the minimum memory that is needed to use the software. For
memory requirements, see the information that comes with the software.
If you have just installed an adapter or memory, the server might have a
memory-address conflict.
• The software is designed to operate on the server.
• Other software works on the server.
• The software works on another server.
2. If you receive any error messages while you use the software, see the
information that comes with the software for a description of the messages and
suggested solutions to the problem.
3. Contact the software vendor.
Chapter 7. Troubleshooting 91
Download from Www.Somanuals.com. All Manuals Search And Download.
Universal Serial Bus (USB) port problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Symptom
Action
1. Make sure that:
A USB device does not work.
• The correct USB device driver is installed.
• The operating system supports USB devices.
• A standard PS/2 keyboard or mouse is not connected to the server. If it is, a
USB keyboard or mouse will not work during the POST.
2. Make sure that the USB configuration optional devices are set correctly in the
Setup Utility program.
3. If you are using a USB hub, disconnect the USB device from the hub and
connect it directly to the server.
Solving power problems
Power problems can be difficult to solve. For example, a short circuit can exist anywhere on any of the
power distribution buses. Usually, a short circuit will cause the power subsystem to shut down because of
an overcurrent condition. To diagnose a power problem, use the following general procedure:
1. Turn off the server and disconnect all ac power cords.
2. Check for loose cables in the power subsystem. Also check for short circuits, for example, if a loose
screw is causing a short circuit on a circuit board.
3. Remove the adapters and disconnect the cables and power cords to all internal and external devices
until the server is at the minimum configuration that is required for the server to start (see “Solving
4. Reconnect all ac power cords and turn on the server. If the server starts successfully, replace the
adapters and devices one at a time until the problem is isolated.
If the server does not start from the minimum configuration, replace the components in the minimum
configuration one at a time until the problem is isolated.
Solving Ethernet controller problems
The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Try the following procedures:
• Make sure that the correct device drivers, which come with the server, are installed and that they are at
the latest level.
• Make sure that the Ethernet cable is installed correctly.
– The cable must be securely attached at all connections. If the cable is attached but the problem
remains, try a different cable.
– If the Ethernet controller is set to operate at 100 Mbps, you must use Category 5 cabling.
92 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
– If you directly connect two servers (without a hub), or if you are not using a hub with X ports, use a
crossover cable. To determine whether a hub has an X port, check the port label. If the label contains
an X, the hub has an X port.
• Determine whether the hub supports auto-negotiation. If it does not, try configuring the integrated
Ethernet controller manually to match the speed and duplex mode of the hub.
• Check the Ethernet controller LEDs on the rear panel of the server. These LEDs indicate whether there
is a problem with the connector, cable, or hub.
– The Ethernet link status LED is lit when the Ethernet controller receives a link pulse from the hub. If the
LED is off, there might be a defective connector or cable or a problem with the hub.
– The Ethernet transmit/receive activity LED is lit when the Ethernet controller sends or receives data
over the Ethernet network. If the Ethernet transmit/receive activity LED is off, make sure that the hub
and network are operating and that the correct device drivers are installed.
• Check the LAN activity LEDs on the rear of the server. The LAN activity LED is lit when data is active on
the Ethernet network. If the LAN activity LED is off, make sure that the hub and network are operating
and that the correct device drivers are installed.
• Check for operating-system-specific causes of the problem.
• Make sure that the device drivers on the client and server are using the same protocol.
If the Ethernet controller still cannot connect to the network but the hardware appears to be working, the
network administrator must investigate other possible causes of the error.
Solving undetermined problems
If the diagnostic tests did not diagnose the failure or if the server is inoperative, use the information in
this section.
If you suspect that a software problem is causing failures (continuous or intermittent), see “Software
Damaged data in CMOS memory or damaged firmware can cause undetermined problems. To reset the
CMOS data, use the password switch 2 (SW4) to override the power-on password and clear the CMOS
memory; see “Locating parts on the system board” on page 13.
Check the LEDs on all the power supplies. If the LEDs indicate that the power supplies are working
correctly, do the following:
1. Turn off the server.
2. Make sure that the server is cabled correctly.
3. Remove or disconnect the following devices, one at a time, until you find the failure. Turn on the server
and reconfigure it each time.
• Any external devices
• Surge-suppressor device (on the server)
• Modem, printer, mouse, and non-Lenovo devices
• Each adapter
• Hard disk drives
• Memory modules: the minimum configuration requirement is 1 GB DIMM per microprocessor (2 GB
in a two-microprocessor configuration)
The following minimum configuration is required for the server to start:
• One microprocessor
• One 1 GB DIMM
• One power supply
Chapter 7. Troubleshooting 93
Download from Www.Somanuals.com. All Manuals Search And Download.
• Power cord
• ServeRAID SAS adapter
• System board assembly
4. Turn on the server. If the problem remains, suspect the following components in the following order:
a. Power supply
b. Power-supply cage
c. Memory
d. Microprocessor
e. System board
If the problem is solved when you remove an adapter from the server but the problem recurs when you
reinstall the same adapter, suspect the adapter; if the problem recurs when you replace the adapter with a
different one, suspect the system board or extender card.
If you suspect a networking problem and the server passes all the system tests, suspect a network cabling
problem that is external to the server.
Event logs
Error codes and messages are displayed in the following types of event logs:
• POST event log: This log contains the three most recent error codes and messages that were generated
during the POST.
• System-event log: This log contains all the POST and system management interrupt (SMI) events. You
can view the system-event log through the Setup Utility program and through the as the IPMI event
log.The system-event log is limited in size. When it is full, new entries will not overwrite existing entries;
therefore, you must periodically save and then clear the system-event log through the Setup Utility
program. When you are troubleshooting, you might have to save and then clear the system-event log to
make the most recent events available for analysis.
Messages are listed on the left side of the screen, and details about the selected message are displayed on
the right side of the screen. To move from one entry to the next, use the Up Arrow and Down Arrow keys.
Viewing event logs without restarting the server
If the server is not hung, methods are available for you to view one or more event logs without restarting
the server.
If IPMItool is installed in the server, you can use it to view the system-event log. Most recent versions of
the Linux operating system come with a current version of IPMItool.
The following table describes the methods that you can use to view the event logs, depending on the
condition of the server. The first two conditions generally do not require that you restart the server.
Table 29. Methods for viewing event logs
Condition
Action
The server is not hung and is connected to a network.
Use IPMItool to view the system-event log.
The server is not hung and is not connected to a network. Use IPMItool locally to view the system-event log.
The server is hung.
You can restart the server and press Del to start the Setup
Utility program and view the system-event log.
94 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
System event log
The system-event log contains messages of three types:
Information
Warning
Error
Information messages do not require action; they record significant system-level events,
such as when the server is started.
Warning messages do not require immediate action; they indicate possible problems, such as
when the recommended maximum ambient temperature is exceeded.
Error messages might require action; they indicate system errors, such as when a fan is
not detected.
Each message contains date and time information, and it indicates the source of the message (POST).
Diagnostic LEDs on the front control panel
Identifying the diagnostic LEDs on the front control panel is a very important method for diagnosing server
Onboard debug digitron
The onboard debug digitron helps trained service technicians to identify server problems. When you turn on
the server, the onboard debug digitron will display debug code on the screen.
Chapter 7. Troubleshooting 95
Download from Www.Somanuals.com. All Manuals Search And Download.
96 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A. RAID battery card assembly
Specifications
The following table provides specifications of the RAID battery card assembly.
Battery technology
LiON
Battery operating temperature (ambient)
10 to 40°C (50 to 104°F) (ThinkServer 8708ELP SAS RAID
Controller Battery and ThinkServer 8708EM2 SAS RAID
Controller Batter)
10 to 55°C (50 to 131°F) (ThinkServer RAID 700 Adapter Battery)
Humidity (storage and operating)
Battery storage temperature
20%-80% (non-condensing) (ThinkServer 8708ELP SAS
RAID Controller Battery and ThinkServer 8708EM2 SAS RAID
Controller Battery)
5%-90% (non-condensing) (ThinkServer RAID 700 Adapter
Battery)
For the ThinkServer 8708ELP SAS RAID Controller Battery and
ThinkServer 8708EM2 SAS RAID Controller Battery:
• < 30 days: 0 to 50°C (32 to 122°F)
• 30-90 days: 0 to 40°C (32 to 104°F)
• > 90 days: 0 to 30°C (32 to 86°F)
For the ThinkServer RAID 700 Adapter Battery:
• 0-90 days: -10 to 45°C (-50 to 113°F)
Battery voltage conditioning
Fast charge rate
Battery pack
<3.7 V
500 mAh
1 cell
Mechanical
3.595 inches x 2.055 inches (ThinkServer 8708ELP SAS RAID
Controller Battery)
2.61 inches x 2.122 inches (ThinkServer 8708EM2 SAS RAID
Controller Battery)
6.6 inches x 2.536 inches (ThinkServer RAID 700 Adapter Battery)
Battery capacity
1350 mAh (ThinkServer 8708ELP SAS RAID Controller Battery)
700 mAh (ThinkServer 8708EM2 SAS RAID Controller Battery)
1590 mAh (ThinkServer RAID 700 Adapter Battery)
Yes
Charge circuitry card
Battery charge time
Auxiliary power
4 hours
Yes
Battery life and data retention time
This sections includes information about the battery life and data retention time.
It is recommended that you replace the battery pack on the battery card assembly once a year or after 500
recharging cycles, whichever comes first.
© Copyright Lenovo 2010, 2011
97
Download from Www.Somanuals.com. All Manuals Search And Download.
The data retention time for the battery card assembly is as follows:
BBU name
Data retention time
ThinkServer 8708ELP SAS RAID Adapter Battery (iBBU05) • 72 hours for 256 Mbytes, using five 32 Mx16 double
data rate two dynamic random access memory
modules (DDR2 DRAMs) (low power)
• 72 hours for 256 Mbytes, using three 64 Mx16 DDR2
DRAMs (low power)
ThinkServer 8708EM2 SAS RAID Controller Battery
(iBBU06)
72 hours for 256 Mbytes, using three 64 Mx16 DDR2
DRAMs (low power)
ThinkServer RAID 700 Adapter Battery (iBBU08)
72 hours for 512 Mbytes, using five 64 Mx16 DDR2
DRAMs (low power)
The data retention time varies according to the following:
• Capacity of the battery pack and the battery load
• Ambient temperature
• Age of the battery
• Numbers of discharge cycles the battery has been through
• DRAM (dynamic random access memory) size
98 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B. Getting help and technical assistance
If you need help, service, or technical assistance or just want more information about Lenovo products, you
will find a wide variety of sources available from Lenovo to assist you. This section contains information
about where to go for additional information about Lenovo and Lenovo products, what to do if you
experience a problem with your system, and whom to call for service, if it is necessary.
Before you call
Before you call, make sure that you have taken these steps to try to solve the problem yourself:
• Check all cables to make sure that they are connected.
• Check the power switches to make sure that the system and any optional devices are turned on.
• Use the troubleshooting information in your system documentation, and use the diagnostic tools that
come with your system. Information about diagnostic tools is in the Hardware Maintenance Manual.
• Go to http://www.lenovo.com/support to check for technical information, hints, tips, and new device
drivers or to submit a request for information.
You can solve many problems without outside assistance by using the information available on the Lenovo
Support site or by following the troubleshooting procedures that Lenovo provides in the documentation
that is provided with your Lenovo product. The documentation that comes with Lenovo systems also
describes the diagnostic tests that you can perform. Most systems, operating systems, and programs come
with documentation that contains troubleshooting procedures and explanations of error messages and error
codes. If you suspect a software problem, see the documentation for the operating system or program.
Using the documentation
Information about your Lenovo system and preinstalled software, if any, or optional device is available in the
documentation that comes with the product. That documentation can include printed documents, online
documents, readme files, and help files. Most of the documentation for your server is on the documentation
DVD provided with your server. See the troubleshooting information in your system documentation for
instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs
might tell you that you need additional or updated device drivers or other software. Lenovo maintains pages
on the World Wide Web where you can get the latest technical information and download device drivers and
Getting help and information from the World Wide Web
On the World Wide Web, the Lenovo Web site has up-to-date information about Lenovo systems, optional
devices, services, and support. For general information about Lenovo products or to purchase Lenovo
© Copyright Lenovo 2010, 2011
99
Download from Www.Somanuals.com. All Manuals Search And Download.
Lenovo Support Web site
Technical support information is available at:
This portal is updated with the latest information about the following subjects:
Downloads & Drivers
Warranty
Download drivers, flash BIOS, and update your software.
Check your warranty status and upgrade your warranty.
Click Need Help? for self-help tips to help diagnose a problem.
Technical Support
ThinkVantage
Learn more about ThinkVantage software to improve productivity and
reduce cost.
Lenovo Forums
Search the community knowledge base for your computer to share and
discover information with other users.
Read or print any publications related to your product.
User Guides & Manuals
Calling for service
During the warranty period, you can get help and information by telephone through the Customer Support
Center.
These services are available during the warranty period:
• Problem determination - Trained personnel are available to assist you with determining a hardware
problem and deciding what action is necessary to fix the problem.
• Hardware repair - If the problem is caused by hardware under warranty, trained service personnel are
available to provide the applicable level of service.
• Engineering Change management - There might be changes that are required after a product has
been sold. Lenovo or your reseller will make selected Engineering Changes (ECs) available that apply
to your hardware.
These items are not covered by the warranty:
• Replacement or use of parts not manufactured for or by Lenovo or non-warranted Lenovo parts
• Identification of software problem sources
• Configuration of the BIOS as part of an installation or upgrade
• Changes, modifications, or upgrades to device drivers
• Installation and maintenance of network operating systems (NOS)
• Installation and maintenance of application programs
Refer to the Warranty and Support Information that comes with your computer for information about your
warranty type and duration. You must retain your proof of purchase to obtain warranty service.
For a list of the Lenovo Support phone numbers for your country or region, go to
http://www.lenovo.com/support/phone or refer to the Warranty and Support Information that comes with
your computer.
Note: Phone numbers are subject to change without notice. If the number for your country or region is not
provided, contact your Lenovo reseller or Lenovo marketing representative.
100 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
If possible, be at your computer when you call. Have the following information available:
• Machine type and model
• Serial numbers of our hardware products
• Description of the problem
• Exact wording of any error messages
• Hardware and software configuration information
Using other services
If you travel with a Lenovo notebook computer or relocate your computer to a country where your desktop,
notebook, or server machine type is sold, your computer might be eligible for International Warranty Service,
which automatically entitles you to obtain warranty service throughout the warranty period. Service will be
performed by service providers authorized to perform warranty service.
Service methods and procedures vary by country, and some services might not be available in all countries.
International Warranty Service is delivered through the method of service (such as depot, carry-in, or
on-site service) that is provided in the servicing country. Service centers in certain countries might not be
able to service all models of a particular machine type. In some countries, fees and restrictions might
apply at the time of service.
To determine whether your computer is eligible for International Warranty Service and to view a list of the
countries where service is available, go to http://www.lenovo.com/support, click Warranty, and follow
the instructions on the screen.
For technical assistance with the installation of, or questions related to, Service Packs for your
preinstalled Microsoft Windows product, refer to the Microsoft Product Support Services Web site at
fees might apply.
Purchasing additional services
During and after the warranty period, you can purchase additional services, such as support for
hardware, operating systems, and application programs; network setup and configuration; upgraded
or extended hardware repair services; and custom installations. Service availability and service name
might vary by country or region. For more information about these services, go to the Lenovo Web site at
Lenovo product service information for Taiwan
Appendix B. Getting help and technical assistance 101
Download from Www.Somanuals.com. All Manuals Search And Download.
102 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C. Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult
your local Lenovo representative for information on the products and services currently available in your
area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that
Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service
that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's
responsibility to evaluate and verify the operation of any other product, program, or service.
Lenovo may have patents or pending patent applications covering subject matter described in this
document. The furnishing of this document does not give you any license to these patents. You can send
license inquiries, in writing, to:
Lenovo (United States), Inc.
1009 Think Place - Building One
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow
disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply
to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically
made to the information herein; these changes will be incorporated in new editions of the publication.
Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support
applications where malfunction may result in injury or death to persons. The information contained in this
document does not affect or change Lenovo product specifications or warranties. Nothing in this document
shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo
or third parties. All information contained in this document was obtained in specific environments and is
presented as an illustration. The result obtained in other operating environments may vary.
Lenovo may use or distribute any of the information you supply in any way it believes appropriate without
incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in
any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of
the materials for this Lenovo product, and use of those Web sites is at your own risk.
Any performance data contained herein was determined in a controlled environment. Therefore, the result
obtained in other operating environments may vary significantly. Some measurements may have been
made on development-level systems and there is no guarantee that these measurements will be the same
on generally available systems. Furthermore, some measurements may have been estimated through
extrapolation. Actual results may vary. Users of this document should verify the applicable data for their
specific environment.
© Copyright Lenovo 2010, 2011
103
Download from Www.Somanuals.com. All Manuals Search And Download.
Trademarks
Lenovo, the Lenovo logo, and ThinkServer are trademarks of Lenovo in the United States, other countries, or
both.
Intel and Intel Xeon are trademarks of Intel Corporation in the United States, other countries, or both.
Microsoft and Windows are trademarks of the Microsoft group of companies.
Linux is a trademark of Linus Torvalds in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Important notes
Processor speed indicates the internal clock speed of the microprocessor; other factors also affect
application performance.
CD or DVD drive speed is the variable read rate. Actual speeds vary and are often less than the possible
maximum.
When referring to processor storage, real and virtual storage, or channel volume, KB stands for 1024 bytes,
MB stands for 1,048,576 bytes, and GB stands for 1,073,741,824 bytes.
When referring to hard disk drive capacity or communications volume, MB stands for 1,000,000 bytes,
and GB stands for 1,000,000,000 bytes. Total user-accessible capacity can vary depending on operating
environments.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives
and population of all hard disk drive bays with the largest currently supported drives that are available
from Lenovo.
Maximum memory might require replacement of the standard memory with an optional memory module.
Lenovo makes no representation or warranties regarding non-Lenovo products and services, including but
not limited to the implied warranties of merchantability and fitness for a particular purpose. These products
are offered and warranted solely by third parties.
Some software might differ from its retail version (if available) and might not include user manuals or all
program functionality.
Product recycling and disposal
This unit must be recycled or discarded according to applicable local and national regulations. Lenovo
encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it
is no longer needed. Lenovo offers a variety of programs and services to assist equipment owners in
recycling their IT products. Information on Lenovo product recycling offerings can be found on Lenovo's
Internet site at http://www.lenovo.com/lenovo/environment/recycling.
Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en la normativa nacional o local
aplicable. Lenovo recomienda a los propietarios de equipos de tecnología de la información (TI) que reciclen
responsablemente sus equipos cuando éstos ya no les sean útiles. Lenovo dispone de una serie de
programas y servicios de devolución de productos, a fin de ayudar a los propietarios de equipos a reciclar
sus productos de TI. Se puede encontrar información sobre las ofertas de reciclado de productos de Lenovo
104 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
en el sitio web de Lenovo
http://www.lenovo.com/lenovo/environment/recycling.
EU Only
Notice: This mark applies only to countries within the European Union (EU) and Norway.
This appliance is labeled in accordance with European Directive 2002/96/EC concerning waste electrical
and electronic equipment (WEEE). The Directive determines the framework for the return and recycling of
used appliances as applicable throughout the European Union. This label is applied to various products to
indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
Remarque : Cette marque s’applique uniquement aux pays de l’Union Européenne et à la Norvège.
L’etiquette du système respecte la Directive européenne 2002/96/EC en matière de Déchets des
Equipements Electriques et Electroniques (DEEE), qui détermine les dispositions de retour et de recyclage
applicables aux systèmes utilisés à travers l’Union européenne. Conformément à la directive, ladite étiquette
précise que le produit sur lequel elle est apposée ne doit pas être jeté mais être récupéré en fin de vie.
In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected
separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per
Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal
waste, but use the collection framework available to customers for the return, recycling, and recovery of
WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and
human health due to the potential presence of hazardous substances in EEE. For proper collection and
treatment, contact your local Lenovo representative.
Particulate contamination
Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in
combination with other environmental factors such as humidity or temperature might pose a risk to the
server that is described in this document. Risks that are posed by the presence of excessive particulate
levels or concentrations of harmful gases include damage that might cause the server to malfunction or
cease functioning altogether. This specification sets forth limits for particulates and gases that are intended
to avoid such damage. The limits must not be viewed or used as definitive limits, because numerous
other factors, such as temperature or moisture content of the air, can influence the impact of particulates
or environmental corrosives and gaseous contaminant transfer. In the absence of specific limits that are
set forth in this document, you must implement practices that maintain particulate and gas levels that are
consistent with the protection of human health and safety. If Lenovo determines that the levels of particulates
or gases in your environment have caused damage to the server, Lenovo may condition provision of repair
Appendix C. Notices 105
Download from Www.Somanuals.com. All Manuals Search And Download.
or replacement of servers or parts on implementation of appropriate remedial measures to mitigate such
environmental contamination. Implementation of such remedial measures is a customer responsibility.
Table 30. Limits for particulates and gases
Contaminant
Limits
Particulate
• The room air must be continuously filtered with 40% atmospheric dust spot efficiency
(MERV 9) according to ASHRAE Standard 52.21.
• Air that enters a data center must be filtered to 99.97% efficiency or greater, using
high-efficiency particulate air (HEPA) filters that meet MIL-STD-282.
• The deliquescent relative humidity of the particulate contamination must be more than 60%2.
• The room must be free of conductive contamination such as zinc whiskers.
Gaseous
• Copper: Class G1 as per ANSI/ISA 71.04-19853
• Silver: Corrosion rate of less than 300 Å in 30 days
1 ASHRAE 52.2-2008 - Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle
Size. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
2 The deliquescent relative humidity of particulate contamination is the relative humidity at which the dust absorbs
enough water to become wet and promote ionic conduction.
3
ANSI/ISA-71.04-1985. Environmental conditions for process measurement and control systems: Airborne
contaminants. Instrument Society of America, Research Triangle Park, North Carolina, U.S.A.
Turkish statement of compliance
The Lenovo product meets the requirements of the Republic of Turkey Directive on the Restriction of the Use
of Certain Hazardous Substances in Electrical and Electronic Equipment (EEE).
Battery return program
This product may contain a lithium or lithium ion battery. Consult your user manual or service manual for
specific battery information. The battery must be recycled or disposed of properly. Recycling facilities may
not be available in your area. For information on disposal or batteries outside the United States, go to
http://www.lenovo.com/lenovo/environment or contact your local waste disposal facility.
Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/EC
concerning batteries and accumulators and waste batteries and accumulators. The Directive determines the
framework for the return and recycling of used batteries and accumulators as applicable throughout the
106 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
European Union. This label is applied to various batteries to indicate that the battery is not to be thrown
away, but rather reclaimed upon end of life per this Directive.
Les batteries ou emballages pour batteries sont étiquetés conformément aux directives européennes
2006/66/EC, norme relative aux batteries et accumulateurs en usage et aux batteries et accumulateurs
usés. Les directives déterminent la marche à suivre en vigueue dans l'Union Européenne pour le retour et
le recyclage des batteries et accumulateurs usés. Cette étiquette est appliquée sur diverses batteries
pour indiquer que la batterie ne doit pas être mise au rebut mais plutôt récupérée en fin de cycle de vie
selon cette norme.
In accordance with the European Directive 2006/66/EC, batteries and accumulators are labeled to indicate
that they are to be collected separately and recycled at end of life. The label on the battery may also include
a chemical symbol for the metal concerned in the battery (Pb for lead, Hg for mercury, and Cd for cadmium).
Users of batteries and accumulators must not dispose of batteries and accumulators as unsorted municipal
waste, but use the collection framework available to customers for the return, recycling, and treatment of
batteries and accumulators. Customer participation is important to minimize any potential effects of batteries
and accumulators on the environment and human health due to the potential presence of hazardous
substances. For proper collection and treatment, go to http://www.lenovo.com/lenovo/environment.
Requirement for batteries containing perchlorate
The following statement applies to users in the state of California, U.S.A.:
California Perchlorate Information:
Products containing CR (manganese dioxide) lithium coin cell batteries may contain perchlorate.
Perchlorate material - special handling may apply, See http://www.dtsc.ca.gov/hazardouswaste/perchlorate/
The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5
Chapter 33. Best Management Practices for Perchlorate Materials. This product/part may include a lithium
manganese dioxide battery which contains a perchlorate substance.
German Ordinance for Work gloss statement
The product is not suitable for use with visual display work place devices according to clause 2 of the
German Ordinance for Work with Visual Display Units.
Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der
Bildschirmarbeitsverordnung geeignet.
Electronic emission notices
The following information applies to Lenovo ThinkServer RD230 server machine types 1043, 1044, 4010,
and 4011.
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Appendix C. Notices 107
Download from Www.Somanuals.com. All Manuals Search And Download.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.
Lenovo is not responsible for any radio or television interference caused by using other than specified or
recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Unauthorized changes or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
United Kingdom telecommunications safety requirement
Notice to Customers
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect connection to public
telecommunication systems in the United Kingdom.
European Union - Compliance to the Electromagnetic Compatibility Directive
This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the
approximation of the laws of the Member States relating to electromagnetic compatibility. Lenovo cannot
accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended
modification of the product, including the installation of option cards from other manufacturers.
This product has been tested and found to comply with the limits for Class A Information Technology
Equipment according to European Standard EN 55022. The limits for Class A equipment were derived for
commercial and industrial environments to provide reasonable protection against interference with licensed
communication equipment.
Warning: This is a Class A product. In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.
German Class A compliance statement
Deutschsprachiger EU Hinweis:
Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen Verträglichkeit
Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG (früher 89/336/EWG) zur
Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU-Mitgliedsstaaten
und hält die Grenzwerte der EN 55022 Klasse A ein.
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu
betreiben. Des Weiteren dürfen auch nur von der Lenovo empfohlene Kabel angeschlossen werden.
Lenovo übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt
ohne Zustimmung der Lenovo verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne
Empfehlung der Lenovo gesteckt/eingebaut werden.
108 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Deutschland:
Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Betriebsmittein
Dieses Produkt entspricht dem „Gesetz über die elektromagnetische Verträglichkeit von Betriebsmitteln“
EMVG (früher „Gesetz über die elektromagnetische Verträglichkeit von Geräten“). Dies ist die Umsetzung der
EU-Richtlinie 2004/108/EG (früher 89/336/EWG) in der Bundesrepublik Deutschland.
Zulassungsbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit
von Betriebsmitteln, EMVG vom 20. Juli 2007 (früher Gesetz über die elektromagnetische
Verträglichkeit von Geräten), bzw. der EMV EG Richtlinie 2004/108/EC (früher 89/336/EWG), für
Geräte der Klasse A.
Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen
- CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo
(Deutschland) GmbH, Gropiusplatz 10, D-70563 Stuttgart.
Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4:
Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
Nach der EN 55022: „Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen
durchzuführen und dafür aufzukommen.“
Nach dem EMVG: „Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer
Genehmigung des Bundesministers für Post und Telekommunikation oder des Bundesamtes für Post und
Telekommunikation betrieben werden. Die Genehmigung wird erteilt, wenn keine elektromagnetischen
Störungen zu erwarten sind.“ (Auszug aus dem EMVG, Paragraph 3, Abs. 4). Dieses Genehmigungsverfahren
ist nach Paragraph 9 EMVG in Verbindung mit der entsprechenden Kostenverordnung (Amtsblatt 14/93)
kostenpflichtig.
Anmerkung: Um die Einhaltung des EMVG sicherzustellen sind die Geräte, wie in den Handbüchern
angegeben, zu installieren und zu betreiben.
Korea Class A compliance statement
Japan VCCI Class A compliance statement
Japan compliance statement for products which connect to the power mains with rated current
less than or equal to 20 A per phase
Appendix C. Notices 109
Download from Www.Somanuals.com. All Manuals Search And Download.
China Class A compliance statement
Taiwan Class A compliance statement
Lenovo product service information for Taiwan
110 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A
problems 85
removing 22
documentation DVD
drives
attention notices
availability
1
2
7
DVD
B
backplane
basic guidelines 17
bays
6
E
EasyStartup
using 76
electrical input
environment
C
cables
7
6
caution statements
minimum 93
1
Configuration Utility program
configuring
connector
cables 64
mouse, non-USB 85
power 89
connectors
rear of the server
9
contamination, particulate and gaseous 6, 106
controller
Ethernet
controller
configuring 80
Ethernet, configuring 80
CRU
CRUs, installing
modes 80
Ethernet card
installing 38
removing 37
D
expansion bays
6
danger statements
1
diagnostic
F
fans
DIMM
installing 21
weight
features and technologies
6
5
© Copyright Lenovo 2010, 2011
111
Download from Www.Somanuals.com. All Manuals Search And Download.
front, controls and indicators
9
K
G
gaseous contamination 6, 106
L
LEDs
rear of the server
LEDs and controls
on the front of the server
locating connectors
backplane 16
logs
9
9
H
hard disk drive
problems 84
heat sink assembly
installing 53
removing 52
help, getting 99
hot-swap drives, SAS or SATA
installing 29
removing 27
M
memory module
installing 21
removing 22
memory modules
specifications
messages
6
humidity
6
system-event 95
installing 61
problems 86
removing 60
specifications
5
I
important notices
installation order
installation rules
installing
1
6
DIMM 21
N
note
1
notices and statements
1
O
optical drive
installing 25
removing 24
optional optical drive
specifications
6
integrated functions
6
integrated network support
internal drives
installing 23
removing 23
5
P
particulate contamination 6, 106
password
112 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
S
installing 29
removing 27
installing 48
SAS/SATA controller
installing 41
SAS/SATA controller 8708EM2
installing 45
serial
server
server components 13
server cover
installing 64
removing 19
PCI card
installing 35
removing 36
power
problems 89, 92
specifications
power supply
installing 57
removing 55
problems
DIMM 85
mouse 85
power 89, 92
undetermined 93
7
6
server firmware, BIOS
serviceability
5
7
Setup Utility program
starting 68
using 67
size
6
specifications
starting
statements and notices
5
R
RAID controller
removing 40
1
system
system board
connectors 14–15
location 13
system board battery
installing 39
removing 39
RAS features
rear view
redundant connection
7
9
5
2
reliability
removing
7
DIMM 22
T
temperature
the POST
6
ThinkServer Web address
trademarks 104
turn off
1
riser card
installing 32
removing 33
server 65
turn on
server 65
© Copyright Lenovo 2010, 2011
113
Download from Www.Somanuals.com. All Manuals Search And Download.
U
updating
USB
using
V
video
problems 87
video controller, integrated
specifications
6
W
Web site
114 ThinkServer Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|