QuickSpecs
Overview
HP ProLiant DL585
1. Eight 64-bit PCI-X I/O Slots (Six 100MHz, two 133MHz)
2. 2 or 4 processors/memory boards
10. Ultra320 Drive Cage, capable of simplex or duplex
configuration)
11. Dual 870-Watt Hot Plug Redundant Power Supplies (hi/lo
line auto-sensing
3. 2 or 4 AMD Opteron 800 Series Processors
4. Up to 64GB of PC2700 DDR SDRAM with Advanced ECC,
running at 266MHz, 48GB of PC2700 running at 333MHz or
32GB of PC3200 running at 400MHz
12. Two Universal Media Bays: 24X CD-ROM IDE and 1.44 MB
Diskette Drive (standard)
13. Multi-Bay floppy and CD-ROM drives, standard on most
models
5. Hot Plug Redundant Fans (standard)
6. 4U (7" Height) Rack Form Factor
7. Tool-less "Snap In" rail solution
8. Server Lifting Handle
14. QuickFind Diagnostic Display (viewable through the Top
Access Panel)
15. Removable Top Access Panel
9. Front Panel LED Display (internal and external health, Unit ID
light) and Power Button
16. Integrated Lights-Out (iLO)- not shown
17. Dual Port NC7782 embedded NIC - not shown
What's New
Support for AMD Opteron Model 852 processors with PC2700
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 1
QuickSpecs
Standard Features
HP ProLiant DL585
Processor
AMD Opteron model 852, running at 2.6 GHz (2 or 4 supported)
Two or four of the
following depending on
Model
AMD Opteron model 850, running at 2.4 GHz (2 or 4 supported)
AMD Opteron model 848, running at 2.2 GHz (2 or 4 supported)
Cache Memory
Upgradability
Chipset
1-MB Integrated Level 2 Cache
Upgradable to quad processing
AMD Opteron 8000 series chipset
Advanced ECC
Memory Protection &
Functionality
Memory
Type
PC2100 DDR SDRAM, running at 266MHz
PC2700 DDR SDRAM, running at 333MHz
PC3200 DDR SDRAM, running at 400MHz
Standard
Maximum
2 GB (2 x 512 MB x 2 Processor Boards) (PC2100 or PC2700DDR SDRAM)
4 GB (2 x 1024 MB x 2 Processor Boards) (PC3200 DDR SDRAM)
32 GB (PC3200 DDR SDRAM)
64 GB (PC2100 or PC2700DDR SDRAM)
NOTE: PC2700 only supported on 2.4GHz and faster single core models and all
dual core models. Also PC3200 only supported on 2.6GHz single core models and
dual core models.
Network Controller
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter
Expansion Slots
Bus speed
Bus number
Hot Plug
No
PCI Voltage
3.3 Volt
3.3 Volt
3.3 Volt
3.3 Volt
3.3 Volt
3.3 Volt
3.3 Volt
3.3 Volt
1
2
3
4
5
6
7
8
64-bit / 133 MHz PCI-X
64-bit / 133 MHz PCI-X
64-bit / 100 MHz PCI-X
64-bit / 100 MHz PCI-X
64-bit / 100 MHz PCI-X
64-bit / 100 MHz PCI-X
64-bit / 100 MHz PCI-X
64-bit / 100 MHz PCI-X
5
6
7
7
8
8
3
3
No
No
No
No
No
No
No
NOTE: For more information regarding PCI-X, please see the following URL: http://www.hp.com/servers/pci-x
NOTE: All slots can accept universal keyed PCI cards.
Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
Slots are enumerated differently based on the operating system. Microsoft operating systems enumerate from lowest to highest
Device ID by bus (starting with the lowest bus).
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 3
QuickSpecs
Standard Features
HP ProLiant DL585
Manageability
Integrated Lights-Out (iLO) Standard Management (ASIC on the System Board)
Storage Controllers
Smart Array 5i Plus Controller (integrated on system board), Dual Channel, Ultra3 (supports RAID 0, 1,
1+0, and 5 across internal hard disk drives) with 64 MB of memory.
64-MB total memory for code, transfer buffers, and read/write cache on the 5i Plus Memory
Module
Connector for Battery Backed Write Cache (BBWC) Enabler
NOTE: The Smart Array 5i Plus Controller is integrated on the system board and is designed to support
the duplex/simplex drive cage. An external SCSI port is not available on the HP ProLiant DL585. External
SCSI solutions require the addition of a PCI or PCI-X option card.
Storage Data Protection The Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory from hard
boot, power, controller, or system board failures.
Standard on all HP ProLiant DL585 Models
Battery charge/life: Up to 72 hours/3 years
Transportable data protection
Increases overall controller performance
NOTE: Safely transport your write cache data to another HP ProLiant DL585 in the data center by
removing the BBWC Enabler and 5i Plus Memory Module simultaneously (connected by short cable).
Storage
Diskette Drive
Optical Drive
Hard Drives
1.44 MB Diskette Drive (slim line) – ejectable for security and serviceability
24x IDE CD-ROM Drive (slim line) – ejectable for security and serviceability
None
Hard Disk Drive
Backplane
Internal Wide Ultra3 backplane supports up to four 1" hard disk drives and is
easily configurable to support simplex (4x1) or duplex mode (2x2) Standard
shipping configuration is the duplex mode.
NOTE: Optional SCSI cable assembly 365483-B21 is required for
connecting Smart Array Controller in a PCI slot to internal hard drive
backplane. Duplex configuration requires two such kits.
Maximum Internal
Storage Type
Hot Plug SCSI
1.20 TB
4 x 300 GB Ultra320 1" drives (internal hot plug
Ultra3 or Ultra320 drive cage)
Interfaces
Serial
1
1
1
1
2
Pointing Device (Mouse)
Graphics
Keyboard
Rear USB Ports
iLO Remote Management 1
Network RJ-45
2
Graphics
Integrated 1280 x 1024, 16M color on PCI local bus, 8 MB of SDRAM video memory
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 4
QuickSpecs
Standard Features
HP ProLiant DL585
Form Factor
Rack (4U = 7 inches), ships with sliding rails and cable management system
Space saving form factor (4U) provides space efficiencies while providing maximum deployment
flexibility
ProLiant Essentials
Foundation Pack
Software
HP Systems Insight
Manager
HP's new HP Systems Insight Manager (HP SIM) helps maximize system
uptime and performance and reduce system maintenance costs by providing
proactive notification of problems before those problems result in unplanned
downtime or reduced productivity. HP SIM are both easy to set up work with
the Insight Management Agents, integrated Light-Out and Remote Insight
Light-Outs Edition, and Version Control Agents to deliver robust fault,
configuration, and asset management as well as remote administration. With
HP SIM customers will also be able to take advantage of role-based security;
the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins
for storage, client, printer, and power management as well as server rapid
deployment, performance management, and workload management. For
SmartStart
SmartStart is a tool that simplifies server setup, providing a rapid way to
deploy reliable and consistent server configurations. For more information,
SmartStart version supported (minimum): SmartStart 7.00.
Management Agents
The Management Agents form the foundation for HP's Intelligent
Manageability strategy. They provide direct, browser-based access to in-
depth instrumentation built into HP servers, workstations, desktops, and
portables, and send alerts to HP Systems Insight Manager and other
enterprise management applications in case of subsystem or environmental
failures. For additional information about the Management Agents and other
management products from HP, please visit the management Web site at
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides automatic delivery of software and
driver change notifications for ProLiant products. Sign up at
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
ROMPaq, support
software, and
configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options available in SmartStart or downloadable from
Software and Drivers download pages, linked from the SmartStart website at
Survey Utility and
diagnostics utilities
The most advanced configuration analysis, reporting and troubleshooting
utilities used by HP and at your fingertips, available in SmartStart.
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 5
QuickSpecs
Standard Features
HP ProLiant DL585
Optional ProLiant
Essentials Value Packs
Optional software offerings that selectively extend the functionality of an
Adaptive Infrastructure to address specific business problems and needs:
Rapid Deployment Pack - an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
Workload Management Pack - provides easier management of
complex environments, improving overall server utilization and
enabling Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
Integrated Lights-Out Advanced Pack - upgrades the Integrated Lights-
Out processor to full virtual presence and control with graphical
console and virtual media.
Performance Management Pack - a performance management
solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions.
Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well
operating system configurations that can be exploited by viruses,
worms, and other blended threats.
Virtual Machine Management Pack - provides central management
and control of virtual machines from Microsoft and VMware.
Integrated approach provides the ability to manage both physical and
virtual resources from a single management console.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to
http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product
QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:
Industry Standard
Compliance
ACPI 1.0a. Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Physical Address Extension (PAE) Support
Microsoft® Logo certifications
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 6
QuickSpecs
Standard Features
HP ProLiant DL585
Remote Management
Integrated Lights-Out (iLO) Standard Management
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Integrated Lights-Out (iLO) Advanced Pack (supports Advanced features such as Graphical Remote
Console and Virtual Floppy - available as a separate option)
Intelligent Manageability Automatic Server Recovery-2 (ASR-2)
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM-Based Setup Utility (RBSU)
Integrated Management Log (IML)
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Redundant/adaptive load balancing NIC Support
Availability
Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance. Up to 64MB
Battery Backed Write Cache protection available on 2P HP ProLiant DL585 models.
Up to four Hot Plug Ultra3 or Ultra320 Hard Drives
Duplex or Simplex SCSI Backplane (Duplex configuration is standard)
Dual Hot Plug Redundant Power Supplies (standard)
PCI-X Technology (six 64-bit/100-MHz and two 64-bit/133MHz PCI-X slots available)
Smart Array 5i Plus Controller with 64GB of Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance.
Fans are 7+1 hot plug redundant and individually removable.
Serviceability
Innovative Diagnostic Lighting
QuickFind Diagnostic Display - precisely depicts all major subsystems of the server (PCI-X I/O,
Memory, CPU, Redundant Cooling, Interlock, Thermtrip) and gives instant visual indication of fault
status. Located on top front of server.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Two ejectable, Universal Media Bay media drives (diskette and CD-ROM standard with
support for optional DVD-ROM drives) are removable without the use of tools
Front access power supplies
PCI Card Guides locks full length PCI cards in place during transit
SCSI Duplex/Simplex Drive Cage connects directly to system board - no cables.
NOTE: Configure your SCSI Duplex/Simplex Drive Cage by means of simple switch (duplex
to simplex)
located on the cage itself. System ships standard in Duplex mode.
Eight individually removable fans connect without cables to the system board
Tool-less removal of system board
Quick Deploy Rails
Tool-less design "snap in" rail
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 7
QuickSpecs
Standard Features
HP ProLiant DL585
Security
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
Network Server Mode
Serial interface control
Administrator's password
Disk configuration lock
Removable Diskette drive
Removable CD-ROM drive
Power Supply
System Fans
Dual 870-Watt Hot Plug Redundant Power Supplies (hi/lo line auto-sensing)
Standard
Maximum
8 Hot plug, redundant fans (individually removable)
8 Hot plug, redundant fans (individually removable)
NOTE: A single cooling zone across the major server subsystems (Memory, I/O, CPU) providing 7x24
cooling in an N + 1 redundant configuration.
Required Cabling
OS Support
For required cabling information, refer to the HP Web site at
Microsoft Windows 2000 Server
Microsoft Windows 2000 Advanced Server
Windows Server 2003, Standard Edition
Windows Server 2003, Enterprise Edition
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 4
SuSE Linux Enterprise Server 8
SuSE Linux Enterprise Server 9
NOTE: 2.2 GHz, 2.4 GHz and 2.6 GHz models.
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL585, please see:
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 8
QuickSpecs
Standard Features
HP ProLiant DL585
Rack Airflow
Requirements
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum
cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you
must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom
to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack
must be a minimum of 7 cm (2.75 inches).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD
provided with the server, or to the server documentation located in the Support section at the following
Rack Mounting
Requirements
HP ProLiant DL585 rack models provide tool-free support for square hole racks (including Compaq/HP
7000, 9000, 10000 and H9 series) with an adjustment range from 28" - 29" in depth.
Factory Express Portfolio HP Factory Express offers configuration, customization, integration and deployment services for HP
for Servers and Storage servers and storage products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging, and custom packaging. HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000
servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and
configurable network switches.
For more information on Factory Express services for your specific server model, please contact your
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom—. AVll eMrasniouanls2S9ea—rchMAnadyD5o,w2n0lo0ad5.
Page 9
QuickSpecs
Standard Features
HP ProLiant DL585
Service and Support
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of
hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide
network of resellers and service providers. In addition 90-days getting started software telephone support
may be covered under the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services.
NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year next business day on-site support.
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware
and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMWare-based IT solutions helping to deliver high level of application availability. Response times range
from 30 minutes for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution.
HP Care Pack services include coverage for the HP branded hardware options qualified for the server,
purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external
monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and
for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty
terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP
qualified rack options installed within the same rack.
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us
NOTE: Additional information regarding worldwide limited warranty and technical support is available
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 10
QuickSpecs
Solutions
HP ProLiant DL585
Solutions
Designed for enterprise customers with growing data centers and application and Internet service
providers that require a rack optimized 4-processor server that delivers maximum performance and high
availability for highly complex, business critical applications. Specifically, the HP ProLiant DL585 would
be excellent for running the following types of applications:
Typical Usage:
High Performance Computing (HPC)
Electronic Design Automation (EDA)/semiconductor
Financial
Large database applications
ERP / CRM
Petrochemical
Life Science and Material Science
Video Rendering
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 11
QuickSpecs
Models
HP ProLiant DL585
DL585R01 O2.6 GHz-
1MB, 4096MB (2P)
380125-xx1
Processor(s)
Cache Memory
Memory
(2) AMD 852 Opteron Processors at 2.6 GHz standard (2 or 4 supported)
1-MB Integrated Level 2 Cache
4 GB of PC3200 DDR SDRAM (Standard) to 32 GB running at 400MHz with
Advanced ECC
Network Controller
Storage Controller
Manageability
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
None ship standard
Internal Storage
Power Supply
Optical Drive
Form Factor
1.20 TB maximum (with optional hard drives)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE Universal Media Bay CD-ROM Drive
Rack 4U
DL585R01 O2.6 GHz-
1MB, 2048MB (2P)
380124-xx1
Processor(s)
Cache Memory
Memory
(2) AMD 852 Opteron Processors at 2.6 GHz standard (2 or 4 supported)
1-MB Integrated Level 2 Cache
2 GB of PC2700 DDR SDRAM (Standard) to 48 GB running at 333MHz or
64GB running at 266MHz with Advanced ECC
Network Controller
Storage Controller
Manageability
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
None ship standard
Internal Storage
Power Supply
Optical Drive
Form Factor
1.20 TB maximum (with optional hard drives)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE Universal Media Bay CD-ROM Drive
Rack 4U
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 12
QuickSpecs
Models
HP ProLiant DL585
DL585R01 O2.4 GHz-
1MB, 2048MB (2P)
378020-xx1
Processor(s)
Cache Memory
Memory
(2) AMD 850 Opteron Processors at 2.4 GHz standard (2 or 4 supported)
1-MB Integrated Level 2 Cache
2 GB of PC2700 DDR SDRAM (Standard) to 48 GB running at 333MHz or
64GB running at 266MHz with Advanced ECC
Network Controller
Storage Controller
Manageability
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
None ship standard
Internal Storage
Power Supply
Optical Drive
Form Factor
1.20 TB maximum (with optional hard drives)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE Universal Media Bay CD-ROM Drive
Rack 4U
DL585R01 O2.2 GHz-
1MB, 2048MB (2P)
356820-xx1
Processor(s)
Cache Memory
Memory
(2) AMD 848 Opteron Processors at 2.2 GHz standard (2 or 4 supported)
1-MB Integrated Level 2 Cache
2 GB of PC2100 DDR SDRAM running at 266MHz (Standard) to 64 GB
(Maximum) with Advanced ECC
Network Controller
Storage Controller
Manageability
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
None ship standard
Internal Storage
Power Supply
Optical Drive
Form Factor
1.20 TB maximum (with optional hard drives)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE Universal Media Bay CD-ROM Drive
Rack 4U
Country Code Key
XX=00
XX=20
XX=29
XX=37
XX=42
XX=AA
XX=B2
US (NOTE: Valid for 2.4 GHz, 2.6 Models)
Brazil (NOTE: Valid for 2.2 GHz, 2.4 GHz, and 2.6 Models only)
Japan
A/P (NOTE: Valid for 2.4 GHz and 2.6 Models only)
Europe (NOTE: Valid for 2.4 GHz and 2.6 Models only)
PRC
WW (NOTE: Valid for 1.8 GHz, and 2.2 GHz Models only)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 13
QuickSpecs
Configuration Information - Factory Integrated Models
HP ProLiant DL585
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
Step 1: Base Configuration
Models
HP ProLiant DL585 Rack CTO Chassis (North America)
390524-405
Factory Integrated Models ship with:
1.44MB Diskette Drive
Dual Port NC7782 embedded NIC
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed Write
Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system board)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Rack 4U Form Factor
HP ProLiant DL585 Rack CTO Chassis (ROW)
Factory Integrated Models ship with:
390524-B21
1.44MB Diskette Drive
Dual Port NC7782 embedded NIC
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed Write
Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system board)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Rack 4U Form Factor
Step 2: Choose Required Options (only one of the following from each list unless otherwise
noted)
Processors
AMD O852 2.6GHz/1000 1MB PC3200 DL585 FIO BASE
NOTE: If four processors are desired, select one 385751-L21 and two 381477-B21.
385751-L21
385750-L21
381078-L21
381077-L21
AMD O852 2.6GHz/1000 1MB PC2700 DL585 FIO BASE
NOTE: If four processor are required, select one 385750-L21 and two 381476-B21.
AMD O850 2.4GHz/800 1MB DL585 FIO BASE
NOTE: If four processors are desired, select one 381078-L21 and two 366725-B21.
AMD O848 2.2GHz/800 1MB DL585 FIO BASE
NOTE: If four processors are desired, select one 381077-L21 and two 359708-B21.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 14
QuickSpecs
Configuration Information - Factory Integrated Models
HP ProLiant DL585
Base Memory
1GB of PC2700 DDR SDRAM DIMM Memory (2x512 MB)
371047-B21
371048-B21
371049-B21
376639-B21
379300-B21
2GB of PC2700 DDR SDRAM DIMM Memory (2x1 GB)
4GB of PC2700 DDR SDRAM DIMM Memory (2x2 GB)
2GB of PC3200 DDR SDRAM DIMM Memory (2x1 GB)
4GB of PC3200 DDR SDRAM DIMM Memory (2x2 GB)
NOTE: Memory must be ordered in like-pairs, i.e. two of the same size.
NOTE: For max memory performance with PC2700 (333MHz), -002 processor
boards should be used in conjunction with no more than 6 PC2700 DIMMs per
processor. -002 board ships standard with 2.4GHZ SKUs and faster SKUs.
Optical Drives
24x IDE Universal Media Bay CD-ROM Drive
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)
HP DVD+R/RW 8X Slim
339866-B21
331903-B21
264007-B21
383975-B21
Step 3: Choose Additional Options for Factory Integration
NOTE: Select from "Options" section below.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 15
QuickSpecs
Options
HP ProLiant DL585
NOTE: Some options may not be factory integratable. Please contact your local sales representative for
additional information.
ProLiant DL585 Unique AMD Opteron 852 2.6 GHz-1MB PC3200 Processor Option Kit for the ProLiant
381477-B21
DL585
Options
NOTE: This Opteron 852 2.6GHz PC3200 processor Option kit (PN 381477-B21)
comes standard with the 012567-001 processor/memory board.
AMD Opteron 852 2.6 GHz-1MB PC2700 Processor Option Kit for the ProLiant
DL585
381476-B21
NOTE: This Opteron 852 2.6GHz PC2700 processor Option kit (PN 381476-B21)
comes standard with the -003 processor/memory board.
AMD Opteron 850 2.4 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE: This Opteron 850 2.4GHz processor Option kit (PN 366725-B21) comes
standard with the -002 processor/memory board.
366725-B21
359708-B21
359707-B21
359706-B21
AMD Opteron 848 2.2 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE: This Opteron 848 2.2GHz processor Option kit (PN 359708-B21) comes
standard with the processor/memory board.
AMD Opteron 844 1.8 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE: This Opteron 844 1.8GHz processor Option kit (PN 359707-B21) comes
standard with the processor/memory board.
AMD Opteron 842 1.6 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE: This Opteron 842 1.6GHz processor Option kit (PN 359706-B21) comes
standard with the processor/memory board.
NOTE: Must order two kits to expand the system from 2 to 4 processors
ProLiant Essentials
Value Pack Software
Rapid Deployment Pack, 1 User, V1.x
NOTE: This license allows 1 server to be managed and deployed via the Deployment
Server.
267196-B21
267196-291
269817-B21
269817-291
Rapid Deployment Pack, 1 User, V1.x (Japan)
NOTE: This license allows 1 server to be managed and deployed via the Deployment
Server.
Rapid Deployment Pack, 10 Users, V1.x
NOTE: This license allows 10 servers to be managed and deployed via the
Deployment Server.
Rapid Deployment Pack, 10 Users, V1.x (Japan)
NOTE: This license allows 10 servers to be managed and deployed via the
Deployment Server.
Flexible Quantity License Kit
302127-B21
302128-B21
303284-B21
License-Only - for use with a Master License Agreement
ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning
Manager version 2.0)
ProLiant Essentials Performance Management Pack v2.0, Single License
NOTE: This license allows 1 server to be managed by Performance Management
Pack.
306696-B21
ProLiant Essentials Performance Management Pack, 10 Pack Server License
374055-B21
306697-B21
Performance Management Pack, flexible license kit
NOTE: A single pack is shipped with a single license key for the total number of
licenses ordered.
ProLiant Essentials Intelligent Networking Pack, 1 License
372906-B21
Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
QuickSpecs
Options
HP ProLiant DL585
ProLiant Essentials Intelligent Networking Pack Flex License
ProLiant Essentials Intelligent Networking Pack Track License
372950-B21
372951-B21
ProLiant Essentials Virtual Machine Management Pack, SINGLE LIC IP CCAO-WGR
ProLiant Essentials Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR
372214-B21
372215-B21
372216-B21
ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-
WGR
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License
371645-B21
372029-B21
371646-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity
License
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for
new servers
371647-B21
378372-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for
installed servers
ProLiant Essentials Server Migration Pack, Single-Server License
ProLiant Essentials Server Migration Pack, Flexible-Quantity License
ProLiant Essentials Server Migration Pack, Tracking license
375345-B21
375346-B21
375347-B21
389941-B21
ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server 10-Desktop
Bundle License
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials
ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the
Software
HP digital asset protection
302316-001
Processor
AMD Opteron 852 2.6 GHz-1MB PC3200 Processor Option Kit
381477-B21
381476-B21
AMD Opteron 852 2.6 GHz-1MB PC2700 Processor Option Kit
NOTE: Two 870W Hot Plug Redundant Power Supplies (low line or high line) are
required if power redundancy is desired with 2.6GHz processors.
AMD Opteron 850 2.4 GHz-1MB Processor Option Kit
AMD Opteron 848 2.2 GHz-1MB Processor Option Kit
AMD Opteron 844 1.8 GHz-1MB Processor Option Kit
AMD Opteron 842 1.6 GHz-1MB Processor Option Kit
NOTE: Must order two kits to expand the system from 2 to 4 processors
366725-B21
359708-B21
359707-B21
359706-B21
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 17
QuickSpecs
Options
HP ProLiant DL585
Memory (DIMMs)
1GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
300679-B21
300680-B21
300682-B21
371047-B21
371048-B21
371049-B21
376639-B21
379300-B21
2GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
4GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
1GB of PC2700 DDR SDRAM DIMM Memory (2 x 512 MB)
2GB of PC2700 DDR SDRAM DIMM Memory (2 x 1 GB)
4GB of PC2700 DDR SDRAM DIMM Memory (2 x 2 GB)
2GB of PC3200 DDR SDRAM DIMM Memory (2 x 1 GB)
4GB of PC3200 DDR SDRAM DIMM Memory (2 x 2 GB)
NOTE: The PC2700 DDR SDRAM DIMM Memory Kits are supported by the 2.4 GHz
and faster models only.
NOTE: For max memory PC2700 performance (333MHz), -002 processor boards
must be used in conjunction with no more than 6 PC2700 DIMMs per processor.
Optical Drives
Hard Drives
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit (Servers)
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)
HP DVD+R/RW 8X Slim
331903-B21
264007-B21
383975-B21
Ultra320 SCSI – Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
146.8-GB 15,000 rpm U320 Universal Hard Drive (1")
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
350964-B22
286716-B22
286714-B22
347708-B22
286778-B22
286776-B22
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3
speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI
HBA to support U320 transfer rates.
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as
capacity, height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature:
U320 Hard Drive QS:
(Worldwide)
(North America)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 18
QuickSpecs
Options
HP ProLiant DL585
Smart Array 6402/128 Controller
273915-B21
273914-B21
291966-B21
291967-B21
Storage Controllers
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
NOTE: The Smart Array 641 and 642 Controller must be placed in the 100MHz slots
only.
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE: This 256-MB Battery-Backed Cache Module upgrade kit supports the Smart
Array 6400 series controller only.
273913-B21
291969-B21
351580-B21
365483-B21
64 MB Battery Backed Write Cache Enabler
NOTE: This 64 MB BBWC supports the Smart Array 641 Controller and Smart Array
642 Controller.
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array
642 Controller.
DL585 Cable Assembly, SCSI, Ultra3, LVDS
NOTE: All DL585 models ship standard with the integrated Smart Array 5i Plus
Controller, which has been designed to deliver maximum performance and availability
across the internal SCSI Duplex backplane.
The Ultra3 SCSI cable is required only if the customer chooses to bypass the
Smart Array 5i Plus Controller and connect slot-based SCSI adapters or RAID
controllers to the internal SCSI Duplex backplane.
Two cables are required to maintain the standard, duplexed configuration of
the backplane.
One cable is required if the simplex configuration is chosen.
The backplane is easily configured to simplex mode by means of a simple switch
duplex to simplex) located on the top of the backplane itself.
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Ultra320 Expansion Module for SA-6402
268351-B21
273911-B21
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols
supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported,
Cache, RAID support, and additional information:
(Smart Array 6400 Series)
(Smart Array 641)
(Smart Array 642)
(SCSI Adapter)
(U320 Adapter)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 19
QuickSpecs
Options
HP ProLiant DL585
Communications
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter
367132-B21
368169-B21
353377-B21
313879-B21
313881-B21
290563-B21
376160-B21
376227-B21
376232-B21
376232-B22
376232-B23
HP NC310F PCI-X 1000SX Gigabit Server Adapter
HP NC1020 PCI 1000T Gigabit Server Adapter
HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter
HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter
HP NC7771 PCI-X 1000T Gigabit Server Adapter
HP NC570C PCI-X Dual-port 4x Fabric Adapter
HP 24-Port 4x Fabric Copper Switch
HP 4x Fabric 1m Copper Cable
HP 4x Fabric 3m Copper Cable
HP 4x Fabric 5m Copper Cable
Management
Security
Integrated Lights-Out (iLO) Advanced Pack
263825-B21
HP/Atalla AXL600L SSL Accelerator Card for ProLiant Servers
AXL300 Accelerator PCI Card for ProLiant Servers
524545-B21
227933-B21
Monitors
Rack-mount Flat Panel Monitors
TFT5110R Flat Panel Monitor (Carbon)
281683-B21
348373-B21
TFT7210R Rack Mounted 17" Monitor
NOTE: Monitors larger than 17'' may be too heavy for use in rack systems.
NOTE: For a complete list of Rack Monitors please view the following URL:
NOTE: For a complete list of Monitors please view one of the following URL:
Tape Drives
NOTE: For complete listing of tape drive offerings see
For recommended tape drive offerings for this ProLiant server see the following:
NOTE: Use of a SCSI adapter to connect these devices is required.
Ultrium Tape Drives - External, Rack-Mount and Array
HP StorageWorks Ultrium 215 Tape Drive, External (Carbon)
Q1545A
HP StorageWorks Ultrium 215 rack-mount (Carbon) - Single drive installed in a 1U
rack-mount kit
A7444A
HP StorageWorks Ultrium 448 Tape Drive, External (Carbonite)
DW017A
DW028A
HP StorageWorks Ultrium 448, Rack-mount (Carbonite) - Single drive installed in a
1U rack-mount kit
HP StorageWorks Ultrium 460 Tape Drive, External (Carbon)
Q1520A
HP StorageWorks Ultrium 460, Rack-mount (Carbon) - Single drive installed in a 3U
rack-mount kit
350546-B21
HP StorageWorks Ultrium 960 Tape Drive, External (Carbonite)
Q1539A
Q1595A
HP StorageWorks Ultrium 960 Rack-mount (Carbonite) - Single drive installed in a 3U
rack-mount kit
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 20
QuickSpecs
Options
HP ProLiant DL585
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for
additional options such as controllers, media, and other related items:
(Worldwide)
(North America)
(Worldwide)
(North America)
For an up-to-date listing of the latest O/S and software support details for HP Ultrium
DAT Drives - External, Rack-Mount and Array Module
HP StorageWorks 1U Rack-Mount Kit with one DAT 72 drive (Carbon)
HP StorageWorks DAT 72 Tape Drive, External (Carbon)
HP StorageWorks DAT 40 Tape Drive, External (Carbon)
HP StorageWorks DAT 24 Tape Drive, External (Flint)
A7443A
Q1523A
C5687C
C1556D
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and other
options:
(Worldwide)
(North America)
For an up-to-date listing of the latest O/S and software support details for HP DAT
Rack-Mount Tape Drive Enclosures
HP StorageWorks 1U Rack-Mount Kit
A7445A
NOTE: The 1U Rack-mount Kit can support up to 2 half-height tape drives and
compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24,
DAT40, DAT72, DLT VS 80, Ultrium 215 and Ultrium 448 tape drives.
HP StorageWorks 3U Rack-Mount Kit
274338-B21
NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape
drives and compatible with multiple Single-Ended and LVD SCSI tape drives including
DAT 24, DAT 40, DAT 72, , DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, Ultrium
448, Ultrium 460, and Ultrium 960 Tape Drives.
HP StorageWorks 5U Rack-Mount Kit
274339-B21
NOTE: The 5U Rack-Mount Kit can support up to 4 full-height tape drives and is
compatible with SDLT 320, Ultrium 230, Ultrium 460, and Ultrium 960 tape drives.
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional
information regarding these kits:
(Worldwide)
(North America)
Accessories for 3U & 5U Rack-mount Tape Drive Kits
LVD Cable Kit, VHDCI/HD68
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.
168048-B21
242381-B21
LVD Cable Kit, HD68/HD68
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 21
QuickSpecs
Options
HP ProLiant DL585
Tape Autoloaders
DAT Autoloader
HP StorageWorks DAT 72x6 Tape Autoloader, External (Flint)
Q1567A
NOTE: Please see the DAT 72x6 Tape Autoloader QuickSpecs for additional options
such as host bus adapters, controllers and media:
(Worldwide)
(North America)
HP StorageWorks 1/8 Tape Autoloader
1/8 Ultrium 460 Tape Autoloader, Tabletop
1/8 SDLT 320 Tape Autoloader, Tabletop
1/8 Ultrium 230 Tape Autoloader, Tabletop
1/8 DLT VS80 Tape Autoloader, Tabletop
1/8 Tape Autoloader Rackmount Kit
AA927A
AA926A
C9572CB
C9264CB
C9268R
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack
NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks SSL1016 Tape Autoloader
SSL1016 Ultrium 460 Tape Autoloader
SSL1016 SDLT 320 Tape Autoloader
330821-B21
330816-B21
NOTE: Please reference the SSL1016 Tape Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL6000 Tape Library
Tape Libraries
Ultrium 960 technology
MSL6030, 1 drive, 30 slots, Ultrium 960
AD606A
AD607A
AD608A
AD609A
AD610A
AD611A
MSL6030, 2 drive, 30 slots, Ultrium 960
MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router
MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router
MSL6060, 2 drive, 60 slots, Ultrium 960
MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router
SDLT 600 technology
MSL6026, 1 drive, 26 slots, SDLT 600
AD582A
AD583A
AD584A
AD585A
AD587A
AD588A
MSL6026, 2 drive, 26 slots, SDLT 600
MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router
MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router
MSL6052, 2 drive, 52 slots, SDLT 600
MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router
Ultrium 460 technology
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 22
QuickSpecs
Options
HP ProLiant DL585
MSL6030, 1 drive, 30 slots, Ultrium 460
AD598A
AD599A
AD600A
AD601A
AD603A
AD604A
MSL6030, 2 drive, 30 slots, Ultrium 460
MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router
MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router
MSL6060, 2 drive, 60 slot Ultrium 460
MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router
NOTE: Please reference the MSL6000 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL5026S2 Tape Library
MSL5026S2, 1 DRV, SDLT320, RM Library
293472-B22
293472-B23
293472-B24
293472-B25
MSL5026S2, 2 DRV, SDLT320, RM Library
MSL5026S2, 1 DRV, SDLT320, Fibre Channel, RM Library
MSL5026S2, 2 DRV, SDLT320, Fibre Channel, RM Library
NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL5052S2 Tape Library
MSL5052S2, 2 DRV, SDLT320, RM Library
293474-B21
293474-B24
MSL5052S2, 2 DRV, SDLT320, Fibre Channel, RM Library
NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL5060 Tape Library
MSL5060, 2 DRV, Ultrium 230, RM Library
301899-B22
301899-B23
MSL5060, 2 DRV, Ultrium 230, Fibre Channel, RM Library
NOTE: Please reference the MSL5060 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks ESL E-Series Tape Libraries
ESL Extended 712e Tape Library, 0 drive, 712 LTO slots
ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots
ESL Extended 322e Tape Library, 0 drive, 322 LTO slots
ESL Extended 286e Tape Library, 0 drive, 286 SDLT slots
ESL E-Series Ultrium 960 drive kit
AA934B
AA935B
AA939B
AA940B
AD595A
AA937A
AA941A
AA936A
AA928A
ESL E Ultrium 460 drive kit
ESL E-Series Ultrium 460-FC drive kit
ESL E SDLT 320 drive kit
ESL E-Series e2400-FC 2G Interface Controller
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 23
QuickSpecs
Options
HP ProLiant DL585
NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
Magento-Optical
Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
300mx, 2 drive, 32 slot jukebox
C1150M
C1160M
C1170M
600mx, 4 drive, 64 slot jukebox
700mx, 2 drive, 76 slot jukebox
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
1200mx, 4 drive, 128 slots
C1104M
C1105M
C1111M
C1107M
C1110M
1200mx, 6 drive, 128 slots
2200mx, 4 drive, 238 slots
2200mx, 6 drive, 238 slots
2200mx, 10 drive, 238 slots
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
HP StorageWorks Ultra Density Optical Storage
1000ux, 2 drive, 32 slot jukebox
AA965A
AA966A
AA968A
AA967A
AA969A
AA970A
AA973A
AA971A
AA972A
AA974A
1900ux, 4 drive, 64 slot jukebox
1900ux, 4 mixed drive, 64 slot jukebox
2300ux, 2 drive, 76 slot jukebox
3800ux, 4 drive, 128 slot jukebox
3800ux, 6 drive, 128 slot jukebox
7100ux, 4 drive, 238 slot jukebox
7100ux, 6 drive, 238 slot jukebox
7100ux, 10 drive, 238 slot jukebox
7100ux, 6 mixed drive, 238 slot jukebox
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 24
QuickSpecs
Options
HP ProLiant DL585
ProLiant Cluster Starter Kit
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see
364023-B21
Cluster Options
the following QuickSpecs at:
(North America)
(Worldwide)
ProLiant Cluster Kit with OpenView Storage Mirroring
364025-B21
NOTE: For additional information regarding the ProLiant Cluster Kit with OpenView
Storage Mirroring please see the following QuickSpecs at:
(North America)
(Worldwide)
ProLiant Cluster HA/F200 for the Entry Level SAN
364026-B21
364026-291
ProLiant Cluster HA/F200 for the Entry Level SAN (Japan)
NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN
please see the following QuickSpecs at:
(North America)
(Worldwide)
ProLiant Cluster HA/F500 for the Enterprise SAN
364024-B21
305199-B24
HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0
and Red Hat EL 3 (2 node license cluster kit)
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL 3
(2 node license cluster kit)
305199-B25
307754-B24
307754-B25
HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and
Red Hat EL 3 (single license version)
HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 (single license
version)
NOTE: For additional information regarding HP Serviceguard for Linux, please see
the following QuickSpecs at:
(North America)
(Worldwide)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 25
QuickSpecs
Options
HP ProLiant DL585
External Storage – Rack HP StorageWorks Modular Smart Array 20
335921-B21
366172-B21
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies.
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies. Includes Smart Array 6402/128 Controller.
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1"
Hot Plug Hard Drives.
HP StorageWorks Modular Smart Array 30 SB
NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies
302969-B21
302970-B21
HP StorageWorks Modular Smart Array 30 DB
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 1" Hot Plug Hard Drives.
Redundant Power Supply 499W
338296-B21
287483-B21
287484-B21
Ultra320 Dual Bus I/O Module for MSA30
Ultra320 Single Bus I/O Module for MSA30
HP StorageWorks
HP StorageWorks Modular Smart Array 500 Generation 2
335880-B21
Modular Smart Array 500 NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for
additional information including configuration steps and additional options needed
for a complete solution at:
(North America)
(Worldwide)
HP StorageWorks
Modular Smart Array
1500 cs
Modular Smart Array 1500 Controller Shelf
AA986A
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for
additional options and configuration information at:
HP StorageWorks
Modular Smart Array
1000
HP StorageWorks Modular Smart Array 1000
201723-B22
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at
(North America)
(Worldwide)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 26
QuickSpecs
Options
HP ProLiant DL585
StorageWorks Options
StorageWorks SAN Switch 2/16
322118-B21
325888-B21
325889-B21
286809-B21
StorageWorks SAN Switch 2/8-EL Upgrade Kit
StorageWorks SAN Switch 2/16-EL Upgrade Kit
StorageWorks Director 2/64
NOTE: Please see the StorageWorks Director 2/64 QuickSpecs for additional
information:
(North America)
(Worldwide)
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
specifications for UPS and PDU units:
Uninterruptible Power
Systems – Rack
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA)
HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int’l)
HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan)
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA)
HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int’l - detachable cord)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug)
204404-001
204404-B31
204404-291
192186-001
192186-002
192186-291
192186-292
192186-B31
192186-B32
192186-B33
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO
Plug)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug)
HP UPS R5500 XR (5000VA, 4500 Watt) High Voltage (NA/JPN, L6-30P)
HP UPS R5500 XR (6000VA, 5400 Watt) High Voltage (Int'l, IEC-309)
HP UPS R12000 XR N+x (12000VA, 12000 Watt) (WW-hardwired)
NOTE: The UPS R12000 XR has a hardwired input and output connection.
192186-AR1
326529-D71
326529-B31
207552-B22
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 27
QuickSpecs
Options
HP ProLiant DL585
HP Power Distribution
Unit with Power
Monitoring
HP Power Distribution Unit with Power Monitoring Model S2324 - dual input, 3
phase, 24A (NA/JPN)
370959-D71
370960-D71
370961-D71
370962-D71
370963-B31
370964-B31
370965-B31
370966-B31
HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3
phase, 24A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1
phase, 40A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1
phase, 40A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S2316 - dual input, 3
phase, 16A (INTL)
HP Power Distribution Unit with Power Monitoring Model S1316 - single input, 3
phase, 16A (INTL)
HP Power Distribution Unit with Power Monitoring Model S2132 - dual input, 1
phase, 32A (INTL)
HP Power Distribution Unit with Power Monitoring Model S1132 - single input, 1
phase, 32A (INTL)
Modular Power
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
252663-D71
(NA, Japan)
Distribution Units 1U/0U
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of
the UPS R3000 XR.
(Up to 32 outlets)
NOTE: 1U/0U mounting
brackets shipped with
the unit (optimized for
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
(NA, Japan)
252663-D72
252663-B31
252663-B21
10000 and 9000 series HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC)
(Int'l)
racks).
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
(WW)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
(WW)
252663-B24
NOTE: This PDU has a detachable input power cord and allows for adaptability to
country specific power requirements. This model may also be used with the high volt
UPS R3000 XR. For North America, need to order cable PN 340653-001.
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper cables
and country specific power cords:
(North America)
(Worldwide)
HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)
USB 1.44-MB External Diskette Drive (Carbonite)
256MB HP Drive Key (USB 2.0)
DC172B
DC141B
PH657A
USB Options
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 28
QuickSpecs
Options
HP ProLiant DL585
Custom Builder
Please see the Enterprise Configurator for configuration assistance at:
Third Party Rack Kit
DL585 rack model support:
287528-B21
The DL580 G2/585 Third Party rack kit 287528-B21 provides support for any rack,
square hole or round hole, (including HP Rack System /E and HP Systems), with an
adjustment range from 23 ½" – 34" deep.
NOTE: The Third party rack kit is required for round hole racks or for square hole
racks that do not conform to the adjustment range of the standard rail that ships with
the server.
Telco Rack Support
DL585 rack model support:
287528-B21
Support for all 2-post Telco racks requires the Third Party option kit 287528-B21,
plus an additional option kit from Rack Solutions. The Rack Solutions brackets can be
Rack Adapter Kit
332815-B21
358254-B21
NOTE: This kit allows HP rack servers to fit in racks that are 24" wide.
HP 5642 Rack-Unassembled
HP Rack 5000 Series
(Graphite Metallic)
Rack Options for Rack
5000 Series
Stabilizer Kit for 5642 Rack (Graphite Carbon)
NOTE: The stabilizing kit is used to prevent rack from tipping over.
374493-B21
374499-B21
Baying Kit for 5642 Rack (Graphite Carbon)
NOTE: The baying kit is used to join two or more HP 5642 racks.
Rack, HP Infrastructure 42U (HV)
Rack, HP Infrastructure 42U (LV)
379005-001
379006-001
292302-B22
257415-B21
257415-B22
245160-B21
245160-B23
245161-B21
245161-B22
245161-B23
245162-B21
245162-B22
245162-B23
245163-B21
245163-B22
245163-B23
HP Rack 10000 Series
(Graphite Metallic)
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet
HP Rack 10842 (42U, 800mm wide) – Pallet
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
HP Rack 10647 (47U) – Pallet
HP Rack 10647 (47U) – Crated
HP Rack 10642 (42U) – Pallet
HP Rack 10642 (42U) – Shock Pallet
HP Rack 10642 (42U) – Crated
HP Rack 10636 (36U) – Pallet
HP Rack 10636 (36U) – Shock Pallet
HP Rack 10636 (36U) – Crated
HP Rack 10622 (22U) – Pallet
HP Rack 10622 (22U) – Shock Pallet
HP Rack 10622 (22U) – Crated
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 29
QuickSpecs
Options
HP ProLiant DL585
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels)
-B23 (crated) used for air shipments of empty racks
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as
height, width, depth, weight, and color:
(Worldwide)
(North America)
NOTE: For additional information regarding Rack Cabinets, please see the following
Rack Options for HP
Rack 10000 Series
NOTE: For additional information regarding Rack Options, please see the following
HP Rack Light Kit (Neon)
361589-B21
251960-B21
246099-B21
246102-B21
255486-B21
221546-xx1
HP Rack Plinth Kit (Carbon)
42U Side Panel – Graphite Metallic
36U Side Panel – Graphite Metallic
47U Side Panel – Graphite Metallic
TFT5600 Rack Keyboard Monitor
Country Code Key (for TFT5600 Rack Keyboard Monitor (PN 221546-xx1))
XX = 001
XX = 031
XX = 041
XX = 051
XX = 061
XX = 071
XX = 081
US
XX = 091
XX = 101
XX = 111
XX = 131
XX = 181
XX = 291
XX = B31
Norway
UK
Sweden/Finland
Switzerland
Portugal
Germany
France
Italy
Belgium
Spain
Denmark
Japan
International
1U Rack Keyboard & Drawer (Carbon)
Country Code Key (for 1U Rack Keyboard & Drawer (PN 257054-xx1))
257054-xx1
XX = 001
XX = 031
XX = 041
XX = 051
XX = 061
XX = 071
XX = 081
US
XX = 091
XX = 101
XX = 111
XX = 131
XX = 181
XX = 291
XX = B31
Norway
UK
Sweden/Finland
Switzerland
Portugal
Germany
France
Italy
Belgium
Spain
Denmark
Japan
International
NOTE: For additional information regarding Rack Options, please see the following
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 30
QuickSpecs
Options
HP ProLiant DL585
HP KVM Switch Options Server Console Switch (KVM), 0 x 1 x 8 port
Server Console Switch (KVM), 0 x 2 x 16 port
IP Console Switch Box (KVM/IP), 1 x 1 x 16
IP Console Switch Box (KVM/IP), 3 x 1 x 16
PS/2 Interface Adapter, 8 pack
336044-B21
336045-B21
262585-B21
262586-B21
262587-B21
262588-B21
336047-B21
262589-B21
373035-B21
263474-B21
263474-B22
263474-B23
263474-B24
263474-B25
371302-B21
371301-A21
371301-031
371301-011
371301-D71
371730-B21
371729-B21
PS/2 Interface Adapter, 1 pack
CAT5 KVM USB Interface Adapter
CAT5 KVM Expansion Module
CAT5 KVM Serial Interface Adapter
CAT5e Cable 3', 4 pack
CAT5e Cable 6', 8 pack
CAT5e Cable 12', 8 pack
CAT5e Cable 20', 4 pack
CAT5e Cable 40', 1 pack
HP 1x4 USB/PS2 KVM Switch, RM (ALL)
HP 1x4 USB/PS2 KVM Switch, TT, (EURO)
HP 1x4 USB/PS2 KVM Switch, TT (UK)
HP 1x4 USB/PS2 KVM Switch, TT, (AUST/NZ)
HP 1x4 USB/PS2 KVM Switch, TT, (NA/JPN)
HP 6ft, 2-Pack, PS2 with audio KVM cable
HP 6ft, 2-Pack, USB with audio KVM cable
NOTE: For additional information regarding HP KVM Switches and options, please see
the following URL:
Service and Support
Offerings (HP Care Pack
Services)
Hardware Services On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
U4607A
U4607E
U4608A
U4608E
6-Hour Call to Repair, On-site Service 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years
U4609A
U4609E
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Installation & Start-up Services
Hardware Installation
U4617A
U4617E
U4618A
Hardware Installation, Electronic
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-
5pm, M-F, excl. HP holidays.
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-
5pm, M-F, excl. HP holidays, Electronic
U4618E
Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
QuickSpecs
Options
HP ProLiant DL585
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech
U4619A
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP
holidays.
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP
holidays, Electronic
U4619E
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
U4620A
U4620E
U6316A
U6316E
U9239A
U9239E
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
Onsite HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
Onsite HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
NOTE: For more information, customer/resellers can contact:
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 32
QuickSpecs
Memory
HP ProLiant DL585
NOTE: Memory configurations listed do not apply to "Factory Integrated Models."
HP ProLiant DL585 2P Models
Standard Memory
4GB PC3200 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 400MHz or
2GB PC2100 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 266MHz or
2GB PC2700 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 333MHz with Advanced ECC
Rules:
Must install a minimum of 2 DIMMs in the processor memory board in slot 2
DIMMs on a processor memory board must be installed in pairs and in bank order
All DIMMs on a processor memory board must be of the same size (512 MB, 1 GB, or 2 GB)
Each processor memory board can have different amounts of memory, ex. Processor memory board 2 = (4) 1 GB, Processor
memory board 1 = (2) 512 MB, Processor memory board 4 = no memory
PC2700 memory support requires -002 processor board
333MHz memory performance requires no more than 6 PC2700 DIMMs per processor board; any more will result in the
memory slowing down to 266MHz
PC3200 memory, running at 400MHz will be supported on a PC3200-only processor board (012567-001) with 4 DIMM
slots, resulting in a system max of 32GB with 4 processors
The following memory options are available from HP:
1GB of PC2100 DDR SDRAM DIMM Memory Kit (2x512 MB)
2GB of PC2100 DDR SDRAM DIMM Memory Kit (2x1 GB)
4GB of PC2100 DDR SDRAM DIMM Memory Kit (2x2 GB)
1GB of PC2700 DDR SDRAM DIMM Memory (2x512 MB)
2GB of PC2700 DDR SDRAM DIMM Memory (2x1 GB)
4GB of PC2700 DDR SDRAM DIMM Memory (2x2 GB)
2GB of PC3200 DDR SDRAM DIMM Memory (2x1 GB)
4GB of PC3200 DDR SDRAM DIMM Memory (2x2 GB)
300679-B21
300680-B21
300682-B21
371047-B21
371048-B21
371049-B21
376639-B21
379300-B21
Standard Memory Configuration
Total Memory = 2 GB
1
2
3
4
5
6
7
8
Board 1
Board 2
512 MB 512 MB
512 MB 512 MB
Empty
Empty
_
Empty
Empty
_
Empty
Empty
_
Empty
Empty
_
Empty
Empty
_
Empty
Empty
_
Not
_
Board 3 (optional)
Board 4 (optional)
installed
Not
_
_
_
_
_
_
_
installed
Examples of other optional configurations include, but are not limited to:
Example #1: Optional Memory Configuration
Standard Memory plus Optional Processor Memory Boards and Processors
Total Memory = 32 GB
1
2
3
4
5
6
7
8
Board 1
Board 2
512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB
512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB
Board 3 (optional)
Board 4 (optional)
2 GB
1 GB
2 GB
1 GB
2 GB
1 GB
2 GB
1 GB
2 GB
1 GB
2 GB
1 GB
2 GB
1 GB
2 GB
1 GB
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 33
QuickSpecs
Memory
HP ProLiant DL585
Example #2: Maximum Memory Configuration
Maximum Memory (Standard replaced with Optional Memory and Optional Memory Board)
Total Memory = 64 GB
1
2
3
4
5
6
7
8
Board 1
Board 2
Board 3 (optional)
Board 4 (optional)
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 34
QuickSpecs
Storage
HP ProLiant DL585
A
B
Diskette Drive eject button
Ejectable: 24x IDE CD-ROM (Slimline)
Ejectable: 1.44-MB Diskette Drive (Slimline)
CD-ROM Drive eject button
C
D
E
870 Watt (low line or high line) Redundant Hot Plug Power Supply
870 Watt (low line or high line) Primary Hot Plug Power Supply
F
0-3
Wide Ultra3 Drive Cage (Duplex or Simplex configurable). Duplex
is standard shipping configuration
Drive Support
Quantity
Position
Supported
Supported
Controller
Ejectable Slim-line Drives
1.44-MB slim-line Diskette Up to 1
Drive
C
Integrated
IDE slim-line CD-ROM
Drive
Up to 1
B
Integrated IDE
Integrated IDE
Slimline DVD-ROM Drive Up to 1
(8X/24X) Option Kit
B or C
Hard Drives
Ultra320 Hot Pluggable Drives
Quantity
Position
Supported
Supported
Controller
1-inch
Up to 4
0-3
Smart Array 5i Plus Controller (integrated on system board)
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
300-GB 10,000 rpm
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
148.8-GB 15,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320
Smart Array Controller or U320 SCSI HBA to support U320 transfer rates.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 35
QuickSpecs
Storage
HP ProLiant DL585
External Storage
Quantity
Position
Supported
Supported
Host Controller or Adapter
Modular Smart Array 30 Up to 13
Family
External
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
Modular Smart Array
1000
Please see the
External
Please see the Modular Smart Array 1000 QuickSpecs (URL below)
for the latest list of supported HBAs
Modular Smart
Array 1000
QuickSpecs
below to
determine
configuration
requirements
Modular Smart Array
1500 cs
Please see the
Modular Smart
Array 1500 cs
QuickSpecs
below to
External
Please see the Modular Smart Array 1500 cs QuickSpecs (URL
below) for the latest list of supported HBAs
determine
configuration
requirements
Maximum Storage Capacity – (External Enclosure Attached)
Internal
External
Total
1.20 TB (4 x 300 GB Ultra320 SCSI 1" Drives)
84.00 TB (20 x (14 x 300 GB Ultra320 SCSI 1" Drives))
85.20 TB
Tape Drives, Tape Autoloaders, and Tape Libraries
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below,
please see the following:
Quantity
Position
Supported
Supported Controller
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 36
QuickSpecs
Storage
HP ProLiant DL585
HP StorageWorks Tape
Drives, External
Ultrium 215
Up to 2
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
Ultrium 230
Ultrium 448
Ultrium 460
DAT 72 Tape Drive
DAT 40 Tape Drive
DAT 24 Tape Drive
HP StorageWorks Tape
Drives, External
Ultrium 960
1
1
External
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
HP StorageWorks Rack-
mount Tape Drive
Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
5U Rack-Mount Kit
HP StorageWorks
Autoloaders, External
DAT 72x6 Tape
Autoloader
1/8 Tape Autoloader
SSL1016 Tape
1 autoloader per
SCSI channel
External
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
Autoloader
HP StorageWorks Tape
Libraries, External
MSL6000 (Ultrium 960 -
based)
MSL6000 (SDLT 600-
based)
Please reference
the MSL Tape
Library
QuickSpecs to
determine
configuration
requirements
MSL6000 (Ultrium 460 -
based)
MSL5026S2 (SDLT 320-
based)
MSL5052S2 (SDLT 320-
based)
HP StorageWorks ESL E- Please reference
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
Series Tape Libraries
ESL 712e
ESL 630e
the ESL E-series
Tape Libraries
QuickSpecs to
determine
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
ESL 322e
ESL 286e
configuration
requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 37
QuickSpecs
Power Specifications
HP ProLiant DL585
Part Number
Spare Kit
384413-001 (870W)
192201-002 (870W)
90 to 264
Operational Input Voltage
Range (V rms)
Frequency Range (Nominal)
(Hz)
47 to 63 (50/60)
Nominal Input Voltage (Vrms)
Max Rated Output Wattage Rating
Nominal Input Current (A rms)
100
800
11.7
115
800
9.9
208
800
5.2
220
800
4.9
230
800
4.7
240
800
4.5
Max Rated Input Wattage Rating (Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%)
1143
1166
70
1111
1134
72
1067
1088
75
1067
1088
75
1067
1088
75
1053
1074
76
Power Factor
Leakage Current (mA)
Maximum Inrush Current (A peak)
Maximum Inrush Current duration
0.98
.43
25
0.98
.50
25
0.98
.90
25
0.98
.96
25
0.98
1.00
25
0.98
1.04
25
20
20
20
20
20
20
System Specifications
DL585 Fully Configured
4 processors, 32 memory modules, 4 hard drives, 8 PCI-X expansion cards, 8 hot plug fans, and 2 hot plug power supplies.
Nominal Input Voltage (Vrms)
Fully Loaded System Input Wattage (W)
Fully Loaded System Input Current (A rms)
Fully Loaded System Thermal (BTU- Hr)
Fully Loaded System VA (Volt-Amp)
System Leakage with all power supplies loaded
(mA)
100
954
10
3253
1004
.87
115
928
8.5
3163
976
1.00
208
890
4.4
3063
909
1.81
220
890
4.1
3063
909
1.91
230
890
4.0
3063
909
2.00
240
879
3.7
2996
897
2.09
System Inrush Current with all power supplies
loaded (A)
50
50
50
50
50
50
Power cord requirements
Nema 5-15P to IEC320-C19
Option no./Spare no: 235603-
001/237457-001
PDU Jumper Cord IEC320-C19 to
IEC320-C20
Option no./Spare no: 295633-
B21/295508-001
PDU Jumper Cord IEC320-C14 to
IEC320-C19
Option no./Spare no: 291034-
001/292241-001
NOTES:
* To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL585
- Click on: "Power Calculator" link (You may need to scroll down to see it.)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 38
QuickSpecs
Power Specifications
HP ProLiant DL585
Power Cords
Country
US
Power Cord Part Number
295529-001
295529-011
295529-021
295529-031
295529-291
AUST
EURO
UK
Japan
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 39
QuickSpecs
Technical Specifications
HP ProLiant DL585
System Unit Rack
Chassis Footprint
(HxWxD)
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)
66 lb (29.9 kg)
Weight
No hard drives installed,
one power supply
Input Requirements
Rated Input Voltage
Rated Input Frequency
Input Power
100 to 120 VAC/200 to 240 VAC
50 to 60 Hz
1135W @ 110 VAC/1125W @ 220 VAC
Rated Input Current
12A (100 VAC), 9.8A (120 VAC), 4.9A (220
VAC)
Max BTU Rating
4000 BTU
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL585
Click on: "Power Calculator" link (You may need to scroll down to see
it.)
Power Supply Output
Rated Steady-State Power 800W/800W (lowline/highline)
Power (per power supply)
Maximum Peak Power
Operating
800W/800W (lowline/highline)
50° to 95° F (10° to 35° C)
-20° to 140° F (-29° to 60° C)
-22° to 122° F (-30° to 50° C)
10% to 70%
Temperature Range
Non-operating
Shipping
Relative Humidity
(non-condensing)
Operating
Non-operating
101.7° F (38.7° C)
5% to 95%
Maximum Wet Bulb
Temperature
Acoustic Noise
NOTE: Listed are the declared A-weighted sound power levels LWAd and the
declared average bystander position sound pressure levels LpAm when
operating in a 23° C ambient environment. Noise emissions were measured
in accordance with ECMA 74 and declared in accordance with ECMA 109.
Idle (Fixed Disk Drives
Spinning)
L WAd (BELS)
L pAm (dBA)
7.3
55
Operating Minimum
(Random Seeks to Fixed
Disks)
L WAd (BELS)
L pAm (dBA)
7.3
55
NOTE: These values apply to 4U rack configuration with the Health Driver
Fan Control active. Configuration tested included 2 AMD Opteron 2.2 GHz
processors, 1 15 krpm hard drive, 2 power supplies, 4 memory/IO fans and
4 CPU fans.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 40
QuickSpecs
Technical Specifications
HP ProLiant DL585
24X Max (or higher) IDE
CD-ROM Drive Slim Line
Disk
Applicable Disk
Capacity
CD-DA, CD-ROM (Mode 1 and 2)
CD-XA, CD-I (Mode 2, Form 1 and 2)
Photo CD (Single and Multi-session)
Mixed Mode (Audio and Data combined)
540 MB (Mode 1, 12 cm)
650 MB (Mode 2, 12 cm)
4.7 x 3.15 in (12 x 8 cm)
4200 rpm maximum
0.6 in/15 mm diameter
1.2 mm
Diameter
Rotational Speed
Center Hole
Thickness
Track Pitch
Mode 1
1.6 µm
Block Size
2,048
Mode 2
2,340, 2,336, 1,024 bytes
2,352 bytes
CD-DA
CD-XA
2,328 bytes
Interface
IDE (ATAPI)
Random
Access Times (typical)
100 ms
Full-Stroke
Line-Out
2000 ms
Audio Output Level
Data Transfer Rate
0.7 VRMS at 47 kOhms
0.6 VRMS at 32 kOhms (maximum volume)
150 KB/s (sustained 1X)
2100 to 3600 KB/s
Headphone
Sustained
Burst
Cache Buffer
128 KB
Start-up Time (typical)
Stop Time
< 7seconds
< 4seconds
Type
Laser Parameters
Semiconductor Laser GaA1As
780 ± 25 nm
Wave Length
Divergence Angle
Output Power
Temperature
Humidity
53.5° ± 1.5°
0.14 mW
Operating Conditions
Dimensions
41° to 113° F (5° to 45° C)
10% to 80%
(HxWxD, maximum)
Weight
1.69 x 5.75 x 8.19 in (4.29 x 15 x 20.8 cm)
2.66 lb (1.2 kg)
Slim Line CD-RW/DVD- Shipping Dimensions
13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm)
5 lb (2.27 kg)
ROM 24X Combo Drive
Shipping Weight
(Multibay)
Disk
Applicable Disk
DVD-ROM
DVD-R (Read Only)
2.6 GB/side DVD-RAM (Read Only)
5.2 GB/side DVD-RAM (Read Only)
CD-ROM Mode-1 data disc
CD-ROM Mode-2 data disc
CD Audio disc
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 41
QuickSpecs
Technical Specifications
HP ProLiant DL585
CD-Extra
CD-RW
CD-R
CD Text
PhotoCD
CD-I (mode 2)
CD-I Ready
CD-Bridge
DVD-ROM
Capacity
DVD-SL 4.7 GB/side
DVD-DL 8.5 GB/side
Double 9.40 GB/side
Sided
DVD-R
3.95 GB/side
DVD-RAM
2.6 GB/side and
5.2 GB/
CD-ROM
Mode-1 650 MB (550 MB)
Mode-2 742 MB (640 MB)
2,048 bytes
Block Size
DVD
CD
2,352 (Mode-0)
2352, 2340,
2336, 2048 bytes
(Mode-1)
2352, 2340,
2336, 2048 bytes
(Mode-2)
Diameter
120 mm, 80 mm (with adapter at vertical
mounting mode)
Loading Mechanism
Tray type
EIDE (ATAPI)
Random
Interface
Access Times (typical)
DVD-ROM < 120 ms, CD-ROM < 110 ms
DVD-ROM < 240 ms, CD-ROM < 160 ms
CD 0.7 Vrms at 47 Kohms Load
Full-Stroke
Line-out
Audio Output Level
(typical)
Data Transfer Rate
(sustained)
DVD-ROM
DVD-RAM
Single Layer
10.8 MB/sec. Max.
2.77 MB/sec. Max
7.2 MB/sec. Max.
CD-ROM
Cache Buffer
Spin-up Time (typical)
MTBF
2 MB
less than 10 seconds
120,000 Power On Hours
(POH)
Ambient Temperature
Relative Humidity
Operating
-22° to 140° F (-30° to 60° C)
10% to 80%
Operating
Storage/Transportation
(HxWxD, maximum)
5% to 95%
Dimensions
0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm)
Option Kit Contents
DVD-ROM drive with installation guide, warranty card, registration card
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 42
QuickSpecs
Technical Specifications
HP ProLiant DL585
Integrated Lights-Out
Standard (integrated on
system board)
Architecture
32-bit PCI-based health and remote management ASIC (Application Specific
Integrated Circuit)
Processor
32-bit RISC processor core running at 66 MHz
Option firmware upgradeable via flash ROM.
Upgradeability
Video Support
Utilizes the host server's embedded video chip. Supports VGA/SVGA, 640 x
480 (256 to 16.7M colors), 800 x 600 (256 to 16.7M colors), 1024 x 768
(256 to 65K colors), 1280 x 1024 (256 colors)
Interfaces
Memory
One Ethernet network connection (10/100 Mb/s)
2-MB Flash ROM
8-MB SDRAM
Operating System
Support
Windows 2000 Server
Windows 2000 Advanced Server
Red Hat 7.x
SuSE 7.0
Client Browser Support
iLO Standard Features
Microsoft Internet Explorer 5.5 or later.
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for up to 12 user accounts with customizable access privileges
iLO Advanced Features Virtual Graphical Remote Console
(optional)
Virtual Floppy Drive
Integrated Smart Array 5i Data Compatible with all Yes
Plus Controller
Smart Array Controllers
Instant Upgrades to other Yes
Smart Array Controllers
Consistent Software
Manageability Tools
Yes
PCI-X Bus
64-bit, 100 MHz (integrated on system board)
PCI-X Peak Data Transfer 800 MB/s
Rate
SCSI Protocols Supported Ultra3, Ultra2
SCSI Peak Data Transfer 160 MB/s per channel
Rate
NOTE: For ProLiant servers having TWO internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
Channels
2 (only one connected)
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
SCSI Ports
0/1
(external/internal)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 43
QuickSpecs
Technical Specifications
HP ProLiant DL585
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
Drives Supported
(maximum)
2
NOTE: Maximum is the total number of internal drives on each specific ProLiant server.
Cache
64 MB Read and/or Write Cache
Battery-Backed Write
Cache
Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB
RAID Support
0, 1, 1+0, 5
Logical Drives (maximum) Maximum = total number of drives
Online Configuration
Yes
Yes
Online Capacity
Expansion
Logical Drive Capacity
Extension
Yes
Yes
Yes
Yes
Online Stripe Size
Migration
Online RAID Level
Migration
Online Spare Support
Automatic Data Recovery Yes
Drive Roaming
Yes
No
Redundant Controllers
Dual Port NC7782
Network Interface
Compatibility
10/100/1000-T
IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
64-bit/133MHz PCI-X
10Base-T (Half-Duplex)
10Base-T (Full-Duplex)
Data Transfer Method
Network Transfer Rate
10 Mb/s
20 Mb/s
100Base-TX (Half-Duplex) 100 Mb/s
100Base-TX (Full-Duplex) 200 Mb/s
1000Base-TX (Half and
Full-Duplex)
2000 Mb/s
Connector
RJ-45
Cable Support
10Base-T
Category 3, 4 or 5 UTP up to 328 ft (100 m)
Category 5 UTP (2 pair); up to 328 ft (100 m)
10/100/1000Base-T
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 44
QuickSpecs
Technical Specifications
HP ProLiant DL585
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows are US registered trademarks of Microsoft Corporation. AMD, Opteron, and Hyper-Transport are trademarks
of AMD Corporation in the United States and other countries.
Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11902
Worldwide — Version 29 — May 5, 2005
Page 45
|