HP Hewlett Packard Network Card DL585 User Manual

QuickSpecs  
Overview  
HP ProLiant DL585  
1. Eight 64-bit PCI-X I/O Slots (Six 100MHz, two 133MHz)  
2. 2 or 4 processors/memory boards  
10. Ultra320 Drive Cage, capable of simplex or duplex  
configuration)  
11. Dual 870-Watt Hot Plug Redundant Power Supplies (hi/lo  
line auto-sensing  
3. 2 or 4 AMD Opteron 800 Series Processors  
4. Up to 64GB of PC2700 DDR SDRAM with Advanced ECC,  
running at 266MHz, 48GB of PC2700 running at 333MHz or  
32GB of PC3200 running at 400MHz  
12. Two Universal Media Bays: 24X CD-ROM IDE and 1.44 MB  
Diskette Drive (standard)  
13. Multi-Bay floppy and CD-ROM drives, standard on most  
models  
5. Hot Plug Redundant Fans (standard)  
6. 4U (7" Height) Rack Form Factor  
7. Tool-less "Snap In" rail solution  
8. Server Lifting Handle  
14. QuickFind Diagnostic Display (viewable through the Top  
Access Panel)  
15. Removable Top Access Panel  
9. Front Panel LED Display (internal and external health, Unit ID  
light) and Power Button  
16. Integrated Lights-Out (iLO)- not shown  
17. Dual Port NC7782 embedded NIC - not shown  
What's New  
Support for AMD Opteron Model 852 processors with PC2700  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 1  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Processor  
AMD Opteron model 852, running at 2.6 GHz (2 or 4 supported)  
Two or four of the  
following depending on  
Model  
AMD Opteron model 850, running at 2.4 GHz (2 or 4 supported)  
AMD Opteron model 848, running at 2.2 GHz (2 or 4 supported)  
Cache Memory  
Upgradability  
Chipset  
1-MB Integrated Level 2 Cache  
Upgradable to quad processing  
AMD Opteron 8000 series chipset  
Advanced ECC  
Memory Protection &  
Functionality  
Memory  
Type  
PC2100 DDR SDRAM, running at 266MHz  
PC2700 DDR SDRAM, running at 333MHz  
PC3200 DDR SDRAM, running at 400MHz  
Standard  
Maximum  
2 GB (2 x 512 MB x 2 Processor Boards) (PC2100 or PC2700DDR SDRAM)  
4 GB (2 x 1024 MB x 2 Processor Boards) (PC3200 DDR SDRAM)  
32 GB (PC3200 DDR SDRAM)  
64 GB (PC2100 or PC2700DDR SDRAM)  
NOTE: PC2700 only supported on 2.4GHz and faster single core models and all  
dual core models. Also PC3200 only supported on 2.6GHz single core models and  
dual core models.  
Network Controller  
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter  
Expansion Slots  
Bus speed  
Bus number  
Hot Plug  
No  
PCI Voltage  
3.3 Volt  
3.3 Volt  
3.3 Volt  
3.3 Volt  
3.3 Volt  
3.3 Volt  
3.3 Volt  
3.3 Volt  
1
2
3
4
5
6
7
8
64-bit / 133 MHz PCI-X  
64-bit / 133 MHz PCI-X  
64-bit / 100 MHz PCI-X  
64-bit / 100 MHz PCI-X  
64-bit / 100 MHz PCI-X  
64-bit / 100 MHz PCI-X  
64-bit / 100 MHz PCI-X  
64-bit / 100 MHz PCI-X  
5
6
7
7
8
8
3
3
No  
No  
No  
No  
No  
No  
No  
NOTE: All slots can accept universal keyed PCI cards.  
Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.  
Slots are enumerated differently based on the operating system. Microsoft operating systems enumerate from lowest to highest  
Device ID by bus (starting with the lowest bus).  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 3  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Manageability  
Integrated Lights-Out (iLO) Standard Management (ASIC on the System Board)  
Storage Controllers  
Smart Array 5i Plus Controller (integrated on system board), Dual Channel, Ultra3 (supports RAID 0, 1,  
1+0, and 5 across internal hard disk drives) with 64 MB of memory.  
64-MB total memory for code, transfer buffers, and read/write cache on the 5i Plus Memory  
Module  
Connector for Battery Backed Write Cache (BBWC) Enabler  
NOTE: The Smart Array 5i Plus Controller is integrated on the system board and is designed to support  
the duplex/simplex drive cage. An external SCSI port is not available on the HP ProLiant DL585. External  
SCSI solutions require the addition of a PCI or PCI-X option card.  
Storage Data Protection The Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory from hard  
boot, power, controller, or system board failures.  
Standard on all HP ProLiant DL585 Models  
Battery charge/life: Up to 72 hours/3 years  
Transportable data protection  
Increases overall controller performance  
NOTE: Safely transport your write cache data to another HP ProLiant DL585 in the data center by  
removing the BBWC Enabler and 5i Plus Memory Module simultaneously (connected by short cable).  
Storage  
Diskette Drive  
Optical Drive  
Hard Drives  
1.44 MB Diskette Drive (slim line) – ejectable for security and serviceability  
24x IDE CD-ROM Drive (slim line) – ejectable for security and serviceability  
None  
Hard Disk Drive  
Backplane  
Internal Wide Ultra3 backplane supports up to four 1" hard disk drives and is  
easily configurable to support simplex (4x1) or duplex mode (2x2) Standard  
shipping configuration is the duplex mode.  
NOTE: Optional SCSI cable assembly 365483-B21 is required for  
connecting Smart Array Controller in a PCI slot to internal hard drive  
backplane. Duplex configuration requires two such kits.  
Maximum Internal  
Storage Type  
Hot Plug SCSI  
1.20 TB  
4 x 300 GB Ultra320 1" drives (internal hot plug  
Ultra3 or Ultra320 drive cage)  
Interfaces  
Serial  
1
1
1
1
2
Pointing Device (Mouse)  
Graphics  
Keyboard  
Rear USB Ports  
iLO Remote Management 1  
Network RJ-45  
2
Graphics  
Integrated 1280 x 1024, 16M color on PCI local bus, 8 MB of SDRAM video memory  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 4  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Form Factor  
Rack (4U = 7 inches), ships with sliding rails and cable management system  
Space saving form factor (4U) provides space efficiencies while providing maximum deployment  
flexibility  
ProLiant Essentials  
Foundation Pack  
Software  
HP Systems Insight  
Manager  
HP's new HP Systems Insight Manager (HP SIM) helps maximize system  
uptime and performance and reduce system maintenance costs by providing  
proactive notification of problems before those problems result in unplanned  
downtime or reduced productivity. HP SIM are both easy to set up work with  
the Insight Management Agents, integrated Light-Out and Remote Insight  
Light-Outs Edition, and Version Control Agents to deliver robust fault,  
configuration, and asset management as well as remote administration. With  
HP SIM customers will also be able to take advantage of role-based security;  
the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins  
for storage, client, printer, and power management as well as server rapid  
deployment, performance management, and workload management. For  
SmartStart  
SmartStart is a tool that simplifies server setup, providing a rapid way to  
deploy reliable and consistent server configurations. For more information,  
SmartStart version supported (minimum): SmartStart 7.00.  
Management Agents  
The Management Agents form the foundation for HP's Intelligent  
Manageability strategy. They provide direct, browser-based access to in-  
depth instrumentation built into HP servers, workstations, desktops, and  
portables, and send alerts to HP Systems Insight Manager and other  
enterprise management applications in case of subsystem or environmental  
failures. For additional information about the Management Agents and other  
management products from HP, please visit the management Web site at  
Subscriber's Choice  
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based  
email subscription service that provides automatic delivery of software and  
driver change notifications for ProLiant products. Sign up at  
and customize your profile to receive various new alerts as they become  
available, on a weekly or monthly basis.  
ROMPaq, support  
software, and  
configuration utilities  
The latest software, drivers, and firmware fully optimized and tested for your  
ProLiant server and options available in SmartStart or downloadable from  
Software and Drivers download pages, linked from the SmartStart website at  
Survey Utility and  
diagnostics utilities  
The most advanced configuration analysis, reporting and troubleshooting  
utilities used by HP and at your fingertips, available in SmartStart.  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 5  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Optional ProLiant  
Essentials Value Packs  
Optional software offerings that selectively extend the functionality of an  
Adaptive Infrastructure to address specific business problems and needs:  
Rapid Deployment Pack - an automated solution for multi-server  
deployment and provisioning, enabling companies to quickly and  
easily adapt to changing business demands.  
Workload Management Pack - provides easier management of  
complex environments, improving overall server utilization and  
enabling Windows® 2000 customers for the first time to confidently  
deploy multiple applications on a single multiprocessor ProLiant  
Server.  
Integrated Lights-Out Advanced Pack - upgrades the Integrated Lights-  
Out processor to full virtual presence and control with graphical  
console and virtual media.  
Performance Management Pack - a performance management  
solution that identifies and explains hardware performance bottlenecks  
on ProLiant servers and attached options enabling users to better  
utilize their valuable resources.  
Intelligent Networking Pack - detects and analyzes network bottlenecks  
or broken network linkages and steers traffic to the optimum route  
based on network conditions.  
Vulnerability and Patch Management Pack - identifies and remediates  
software security vulnerabilities due to missing patches as well  
operating system configurations that can be exploited by viruses,  
worms, and other blended threats.  
Virtual Machine Management Pack - provides central management  
and control of virtual machines from Microsoft and VMware.  
Integrated approach provides the ability to manage both physical and  
virtual resources from a single management console.  
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to  
http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product  
QuickSpecs for more information.  
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:  
Industry Standard  
Compliance  
ACPI 1.0a. Compliant  
PCI 2.2 Compliant  
PXE Support  
WOL Support  
Physical Address Extension (PAE) Support  
Microsoft® Logo certifications  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 6  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Remote Management  
Integrated Lights-Out (iLO) Standard Management  
Virtual Text Remote Console  
Virtual Power Button Control  
Dedicated LAN Connectivity  
Automatic IP Configuration via DHCP/DNS/WINS  
Industry Standard 128-bit Secure Sockets Layer (SSL) Security  
IML and iLO Event Logging  
Support for 12 user accounts with customizable access privileges  
Integrated Lights-Out (iLO) Advanced Pack (supports Advanced features such as Graphical Remote  
Console and Virtual Floppy - available as a separate option)  
Intelligent Manageability Automatic Server Recovery-2 (ASR-2)  
HP Systems Insight Manager  
Redundant ROM  
Remote Flash ROM  
ROM-Based Setup Utility (RBSU)  
Integrated Management Log (IML)  
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)  
Redundant/adaptive load balancing NIC Support  
Availability  
Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler  
provides transportable data protection and increases overall controller performance. Up to 64MB  
Battery Backed Write Cache protection available on 2P HP ProLiant DL585 models.  
Up to four Hot Plug Ultra3 or Ultra320 Hard Drives  
Duplex or Simplex SCSI Backplane (Duplex configuration is standard)  
Dual Hot Plug Redundant Power Supplies (standard)  
PCI-X Technology (six 64-bit/100-MHz and two 64-bit/133MHz PCI-X slots available)  
Smart Array 5i Plus Controller with 64GB of Battery Backed Write Cache (BBWC) Enabler  
provides transportable data protection and increases overall controller performance.  
Fans are 7+1 hot plug redundant and individually removable.  
Serviceability  
Innovative Diagnostic Lighting  
QuickFind Diagnostic Display - precisely depicts all major subsystems of the server (PCI-X I/O,  
Memory, CPU, Redundant Cooling, Interlock, Thermtrip) and gives instant visual indication of fault  
status. Located on top front of server.  
Tool-less, virtually cable-less interior design  
Tool-less access to interior of server  
Two ejectable, Universal Media Bay media drives (diskette and CD-ROM standard with  
support for optional DVD-ROM drives) are removable without the use of tools  
Front access power supplies  
PCI Card Guides locks full length PCI cards in place during transit  
SCSI Duplex/Simplex Drive Cage connects directly to system board - no cables.  
NOTE: Configure your SCSI Duplex/Simplex Drive Cage by means of simple switch (duplex  
to simplex)  
located on the cage itself. System ships standard in Duplex mode.  
Eight individually removable fans connect without cables to the system board  
Tool-less removal of system board  
Quick Deploy Rails  
Tool-less design "snap in" rail  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 7  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Security  
Power-on password  
Keyboard password  
Diskette drive control  
Diskette boot control  
Network Server Mode  
Serial interface control  
Administrator's password  
Disk configuration lock  
Removable Diskette drive  
Removable CD-ROM drive  
Power Supply  
System Fans  
Dual 870-Watt Hot Plug Redundant Power Supplies (hi/lo line auto-sensing)  
Standard  
Maximum  
8 Hot plug, redundant fans (individually removable)  
8 Hot plug, redundant fans (individually removable)  
NOTE: A single cooling zone across the major server subsystems (Memory, I/O, CPU) providing 7x24  
cooling in an N + 1 redundant configuration.  
Required Cabling  
OS Support  
For required cabling information, refer to the HP Web site at  
Microsoft Windows 2000 Server  
Microsoft Windows 2000 Advanced Server  
Windows Server 2003, Standard Edition  
Windows Server 2003, Enterprise Edition  
Red Hat Enterprise Linux 3  
Red Hat Enterprise Linux 4  
SuSE Linux Enterprise Server 8  
SuSE Linux Enterprise Server 9  
NOTE: 2.2 GHz, 2.4 GHz and 2.6 GHz models.  
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS  
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL585, please see:  
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web  
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 8  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Rack Airflow  
Requirements  
Rack 10000 series Cabinets  
The increasing power of new high-performance processor technology requires increased cooling  
                                                 
                                                   
                                                    
                                                       
                                                         
                                                           
                                                             
                                                               
                                                                  
                                                                   
                                                                     
                                                                      
                                                                       
                                                                         
                                                                           
                                                                             
                                                                               
                                                                                 
                                                                                  
                                                                                    
                                                                                     
                                                                                      
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum  
cooling, allowing these racks to be fully loaded with servers using the latest processors.  
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure  
adequate airflow and to prevent damage to the equipment:  
Front and rear doors: If your 42U server rack includes closing front and rear doors, you  
must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom  
to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).  
Side: The clearance between the installed rack component and the side panels of the rack  
must be a minimum of 7 cm (2.75 inches).  
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This  
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling  
that can lead to thermal damage.  
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD  
provided with the server, or to the server documentation located in the Support section at the following  
Rack Mounting  
Requirements  
HP ProLiant DL585 rack models provide tool-free support for square hole racks (including Compaq/HP  
7000, 9000, 10000 and H9 series) with an adjustment range from 28" - 29" in depth.  
Factory Express Portfolio HP Factory Express offers configuration, customization, integration and deployment services for HP  
for Servers and Storage servers and storage products. Customers can choose how their factory solutions are built, tested,  
integrated, shipped and deployed.  
Factory Express offers service packages for simple configuration, racking, installation, complex  
configuration and design services as well as individual factory services, such as image loading, asset  
tagging, and custom packaging. HP products supported through Factory Express include a wide array of  
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000  
servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and  
configurable network switches.  
For more information on Factory Express services for your specific server model, please contact your  
DowDnAloa-d1f1ro9m0W2ww.SWomoarnlduawlsid.ceom. AVll eMrasniouanls2S9earchMAnadyD5o,w2n0lo0ad5.  
Page 9  
QuickSpecs  
Standard Features  
HP ProLiant DL585  
Service and Support  
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of  
hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide  
network of resellers and service providers. In addition 90-days getting started software telephone support  
may be covered under the warranty or available for an additional fee. Enhancements to warranty  
services are available through HP Care Pack services.  
NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year next business day on-site support.  
Care Pack services provide a range of life cycle support options that let you choose the service levels that  
meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware  
and software services are available including:  
Installation and start up  
Education courses  
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7  
days call window with options including 4-hour response or 6-hour Call To Repair  
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and  
VMWare-based IT solutions helping to deliver high level of application availability. Response times range  
from 30 minutes for critical problems to 2 hours.  
System Management, Performance Services and Mission Critical Support Solution.  
HP Care Pack services include coverage for the HP branded hardware options qualified for the server,  
purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external  
monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and  
for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty  
terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP  
qualified rack options installed within the same rack.  
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or  
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us  
NOTE: Additional information regarding worldwide limited warranty and technical support is available  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 10  
QuickSpecs  
Solutions  
HP ProLiant DL585  
Solutions  
Designed for enterprise customers with growing data centers and application and Internet service  
providers that require a rack optimized 4-processor server that delivers maximum performance and high  
availability for highly complex, business critical applications. Specifically, the HP ProLiant DL585 would  
be excellent for running the following types of applications:  
Typical Usage:  
High Performance Computing (HPC)  
Electronic Design Automation (EDA)/semiconductor  
Financial  
Large database applications  
ERP / CRM  
Petrochemical  
Life Science and Material Science  
Video Rendering  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 11  
QuickSpecs  
Models  
HP ProLiant DL585  
DL585R01 O2.6 GHz-  
1MB, 4096MB (2P)  
380125-xx1  
Processor(s)  
Cache Memory  
Memory  
                                                 
                                                  
                                                    
                                                     
                                                       
                                                        
                                                          
                                                            
                                                             
                                                              
                                                               
(2) AMD 852 Opteron Processors at 2.6 GHz standard (2 or 4 supported)  
1-MB Integrated Level 2 Cache  
4 GB of PC3200 DDR SDRAM (Standard) to 32 GB running at 400MHz with  
Advanced ECC  
Network Controller  
Storage Controller  
Manageability  
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network  
adapter  
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed  
Write Cache Enabler (integrated on system board)  
Integrated Lights-Out (iLO) Standard management (integrated on system  
board)  
Hard Drives  
None ship standard  
Internal Storage  
Power Supply  
Optical Drive  
Form Factor  
1.20 TB maximum (with optional hard drives)  
Two 870W Hot Plug Redundant Power Supplies (low line or high line)  
24x IDE Universal Media Bay CD-ROM Drive  
Rack 4U  
DL585R01 O2.6 GHz-  
1MB, 2048MB (2P)  
380124-xx1  
Processor(s)  
Cache Memory  
Memory  
(2) AMD 852 Opteron Processors at 2.6 GHz standard (2 or 4 supported)  
1-MB Integrated Level 2 Cache  
2 GB of PC2700 DDR SDRAM (Standard) to 48 GB running at 333MHz or  
64GB running at 266MHz with Advanced ECC  
Network Controller  
Storage Controller  
Manageability  
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network  
adapter  
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed  
Write Cache Enabler (integrated on system board)  
Integrated Lights-Out (iLO) Standard management (integrated on system  
board)  
Hard Drives  
None ship standard  
Internal Storage  
Power Supply  
Optical Drive  
Form Factor  
1.20 TB maximum (with optional hard drives)  
Two 870W Hot Plug Redundant Power Supplies (low line or high line)  
24x IDE Universal Media Bay CD-ROM Drive  
Rack 4U  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 12  
QuickSpecs  
Models  
HP ProLiant DL585  
DL585R01 O2.4 GHz-  
1MB, 2048MB (2P)  
378020-xx1  
Processor(s)  
Cache Memory  
Memory  
                                                 
                                                  
                                                    
                                                     
                                                       
                                                        
                                                          
                                                            
                                                             
                                                              
                                                               
(2) AMD 850 Opteron Processors at 2.4 GHz standard (2 or 4 supported)  
1-MB Integrated Level 2 Cache  
2 GB of PC2700 DDR SDRAM (Standard) to 48 GB running at 333MHz or  
64GB running at 266MHz with Advanced ECC  
Network Controller  
Storage Controller  
Manageability  
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network  
adapter  
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed  
Write Cache Enabler (integrated on system board)  
Integrated Lights-Out (iLO) Standard management (integrated on system  
board)  
Hard Drives  
None ship standard  
Internal Storage  
Power Supply  
Optical Drive  
Form Factor  
1.20 TB maximum (with optional hard drives)  
Two 870W Hot Plug Redundant Power Supplies (low line or high line)  
24x IDE Universal Media Bay CD-ROM Drive  
Rack 4U  
DL585R01 O2.2 GHz-  
1MB, 2048MB (2P)  
356820-xx1  
Processor(s)  
Cache Memory  
Memory  
(2) AMD 848 Opteron Processors at 2.2 GHz standard (2 or 4 supported)  
1-MB Integrated Level 2 Cache  
2 GB of PC2100 DDR SDRAM running at 266MHz (Standard) to 64 GB  
(Maximum) with Advanced ECC  
Network Controller  
Storage Controller  
Manageability  
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network  
adapter  
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed  
Write Cache Enabler (integrated on system board)  
Integrated Lights-Out (iLO) Standard management (integrated on system  
board)  
Hard Drives  
None ship standard  
Internal Storage  
Power Supply  
Optical Drive  
Form Factor  
1.20 TB maximum (with optional hard drives)  
Two 870W Hot Plug Redundant Power Supplies (low line or high line)  
24x IDE Universal Media Bay CD-ROM Drive  
Rack 4U  
Country Code Key  
XX=00  
XX=20  
XX=29  
XX=37  
XX=42  
XX=AA  
XX=B2  
US (NOTE: Valid for 2.4 GHz, 2.6 Models)  
Brazil (NOTE: Valid for 2.2 GHz, 2.4 GHz, and 2.6 Models only)  
Japan  
A/P (NOTE: Valid for 2.4 GHz and 2.6 Models only)  
Europe (NOTE: Valid for 2.4 GHz and 2.6 Models only)  
PRC  
WW (NOTE: Valid for 1.8 GHz, and 2.2 GHz Models only)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 13  
QuickSpecs  
Configuration Information - Factory Integrated Models  
HP ProLiant DL585  
NOTE: HP does not allow factory integration of options into standard models listed above.  
Configure-to-order servers must start with a CTO Chassis.  
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.  
Step 1: Base Configuration  
Models  
HP ProLiant DL585 Rack CTO Chassis (North America)  
390524-405  
Factory Integrated Models ship with:  
1.44MB Diskette Drive  
Dual Port NC7782 embedded NIC  
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed Write  
Cache Enabler (integrated on system board)  
Integrated Lights-Out (iLO) Standard management (integrated on system board)  
Two 870W Hot Plug Redundant Power Supplies (low line or high line)  
Rack 4U Form Factor  
HP ProLiant DL585 Rack CTO Chassis (ROW)  
Factory Integrated Models ship with:  
390524-B21  
1.44MB Diskette Drive  
Dual Port NC7782 embedded NIC  
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed Write  
Cache Enabler (integrated on system board)  
Integrated Lights-Out (iLO) Standard management (integrated on system board)  
Two 870W Hot Plug Redundant Power Supplies (low line or high line)  
Rack 4U Form Factor  
Step 2: Choose Required Options (only one of the following from each list unless otherwise  
noted)  
Processors  
AMD O852 2.6GHz/1000 1MB PC3200 DL585 FIO BASE  
NOTE: If four processors are desired, select one 385751-L21 and two 381477-B21.  
385751-L21  
385750-L21  
381078-L21  
381077-L21  
AMD O852 2.6GHz/1000 1MB PC2700 DL585 FIO BASE  
NOTE: If four processor are required, select one 385750-L21 and two 381476-B21.  
AMD O850 2.4GHz/800 1MB DL585 FIO BASE  
NOTE: If four processors are desired, select one 381078-L21 and two 366725-B21.  
AMD O848 2.2GHz/800 1MB DL585 FIO BASE  
NOTE: If four processors are desired, select one 381077-L21 and two 359708-B21.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 14  
QuickSpecs  
Configuration Information - Factory Integrated Models  
HP ProLiant DL585  
Base Memory  
1GB of PC2700 DDR SDRAM DIMM Memory (2x512 MB)  
371047-B21  
371048-B21  
371049-B21  
376639-B21  
379300-B21  
2GB of PC2700 DDR SDRAM DIMM Memory (2x1 GB)  
4GB of PC2700 DDR SDRAM DIMM Memory (2x2 GB)  
2GB of PC3200 DDR SDRAM DIMM Memory (2x1 GB)  
4GB of PC3200 DDR SDRAM DIMM Memory (2x2 GB)  
NOTE: Memory must be ordered in like-pairs, i.e. two of the same size.  
NOTE: For max memory performance with PC2700 (333MHz), -002 processor  
boards should be used in conjunction with no more than 6 PC2700 DIMMs per  
processor. -002 board ships standard with 2.4GHZ SKUs and faster SKUs.  
Optical Drives  
24x IDE Universal Media Bay CD-ROM Drive  
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit  
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)  
HP DVD+R/RW 8X Slim  
339866-B21  
331903-B21  
264007-B21  
383975-B21  
Step 3: Choose Additional Options for Factory Integration  
NOTE: Select from "Options" section below.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 15  
QuickSpecs  
Options  
HP ProLiant DL585  
NOTE: Some options may not be factory integratable. Please contact your local sales representative for  
additional information.  
ProLiant DL585 Unique AMD Opteron 852 2.6 GHz-1MB PC3200 Processor Option Kit for the ProLiant  
381477-B21  
DL585  
Options  
NOTE: This Opteron 852 2.6GHz PC3200 processor Option kit (PN 381477-B21)  
comes standard with the 012567-001 processor/memory board.  
AMD Opteron 852 2.6 GHz-1MB PC2700 Processor Option Kit for the ProLiant  
DL585  
381476-B21  
NOTE: This Opteron 852 2.6GHz PC2700 processor Option kit (PN 381476-B21)  
comes standard with the -003 processor/memory board.  
AMD Opteron 850 2.4 GHz-1MB Processor Option Kit for the ProLiant DL585  
NOTE: This Opteron 850 2.4GHz processor Option kit (PN 366725-B21) comes  
standard with the -002 processor/memory board.  
366725-B21  
359708-B21  
359707-B21  
359706-B21  
AMD Opteron 848 2.2 GHz-1MB Processor Option Kit for the ProLiant DL585  
NOTE: This Opteron 848 2.2GHz processor Option kit (PN 359708-B21) comes  
standard with the processor/memory board.  
AMD Opteron 844 1.8 GHz-1MB Processor Option Kit for the ProLiant DL585  
NOTE: This Opteron 844 1.8GHz processor Option kit (PN 359707-B21) comes  
standard with the processor/memory board.  
AMD Opteron 842 1.6 GHz-1MB Processor Option Kit for the ProLiant DL585  
NOTE: This Opteron 842 1.6GHz processor Option kit (PN 359706-B21) comes  
standard with the processor/memory board.  
NOTE: Must order two kits to expand the system from 2 to 4 processors  
ProLiant Essentials  
Value Pack Software  
Rapid Deployment Pack, 1 User, V1.x  
NOTE: This license allows 1 server to be managed and deployed via the Deployment  
Server.  
267196-B21  
267196-291  
269817-B21  
269817-291  
Rapid Deployment Pack, 1 User, V1.x (Japan)  
NOTE: This license allows 1 server to be managed and deployed via the Deployment  
Server.  
Rapid Deployment Pack, 10 Users, V1.x  
NOTE: This license allows 10 servers to be managed and deployed via the  
Deployment Server.  
Rapid Deployment Pack, 10 Users, V1.x (Japan)  
NOTE: This license allows 10 servers to be managed and deployed via the  
Deployment Server.  
Flexible Quantity License Kit  
302127-B21  
302128-B21  
303284-B21  
License-Only - for use with a Master License Agreement  
ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning  
Manager version 2.0)  
ProLiant Essentials Performance Management Pack v2.0, Single License  
NOTE: This license allows 1 server to be managed by Performance Management  
Pack.  
306696-B21  
ProLiant Essentials Performance Management Pack, 10 Pack Server License  
374055-B21  
306697-B21  
Performance Management Pack, flexible license kit  
NOTE: A single pack is shipped with a single license key for the total number of  
licenses ordered.  
ProLiant Essentials Intelligent Networking Pack, 1 License  
372906-B21  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
QuickSpecs  
Options  
HP ProLiant DL585  
ProLiant Essentials Intelligent Networking Pack Flex License  
ProLiant Essentials Intelligent Networking Pack Track License  
372950-B21  
372951-B21  
ProLiant Essentials Virtual Machine Management Pack, SINGLE LIC IP CCAO-WGR  
ProLiant Essentials Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR  
372214-B21  
372215-B21  
372216-B21  
ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-  
WGR  
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License  
ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License  
371645-B21  
372029-B21  
371646-B21  
ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity  
License  
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for  
new servers  
371647-B21  
378372-B21  
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for  
installed servers  
ProLiant Essentials Server Migration Pack, Single-Server License  
ProLiant Essentials Server Migration Pack, Flexible-Quantity License  
ProLiant Essentials Server Migration Pack, Tracking license  
375345-B21  
375346-B21  
375347-B21  
389941-B21  
ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server 10-Desktop  
Bundle License  
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials  
ProLiant Essentials Value Pack product QuickSpecs for more information.  
NOTE: For more information regarding ProLiant Essentials Software, please see the  
Software  
HP digital asset protection  
302316-001  
Processor  
AMD Opteron 852 2.6 GHz-1MB PC3200 Processor Option Kit  
381477-B21  
381476-B21  
AMD Opteron 852 2.6 GHz-1MB PC2700 Processor Option Kit  
NOTE: Two 870W Hot Plug Redundant Power Supplies (low line or high line) are  
required if power redundancy is desired with 2.6GHz processors.  
AMD Opteron 850 2.4 GHz-1MB Processor Option Kit  
AMD Opteron 848 2.2 GHz-1MB Processor Option Kit  
AMD Opteron 844 1.8 GHz-1MB Processor Option Kit  
AMD Opteron 842 1.6 GHz-1MB Processor Option Kit  
NOTE: Must order two kits to expand the system from 2 to 4 processors  
366725-B21  
359708-B21  
359707-B21  
359706-B21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 17  
QuickSpecs  
Options  
HP ProLiant DL585  
Memory (DIMMs)  
1GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)  
300679-B21  
300680-B21  
300682-B21  
371047-B21  
371048-B21  
371049-B21  
376639-B21  
379300-B21  
2GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)  
4GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)  
1GB of PC2700 DDR SDRAM DIMM Memory (2 x 512 MB)  
2GB of PC2700 DDR SDRAM DIMM Memory (2 x 1 GB)  
4GB of PC2700 DDR SDRAM DIMM Memory (2 x 2 GB)  
2GB of PC3200 DDR SDRAM DIMM Memory (2 x 1 GB)  
4GB of PC3200 DDR SDRAM DIMM Memory (2 x 2 GB)  
NOTE: The PC2700 DDR SDRAM DIMM Memory Kits are supported by the 2.4 GHz  
and faster models only.  
NOTE: For max memory PC2700 performance (333MHz), -002 processor boards  
must be used in conjunction with no more than 6 PC2700 DIMMs per processor.  
Optical Drives  
Hard Drives  
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit (Servers)  
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)  
HP DVD+R/RW 8X Slim  
331903-B21  
264007-B21  
383975-B21  
Ultra320 SCSI – Universal Hot Plug  
300-GB 10,000 rpm U320 Universal Hard Drive (1")  
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")  
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")  
146.8-GB 15,000 rpm U320 Universal Hard Drive (1")  
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")  
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")  
350964-B22  
286716-B22  
286714-B22  
347708-B22  
286778-B22  
286776-B22  
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3  
speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI  
HBA to support U320 transfer rates.  
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as  
capacity, height, width, interface, transfer rate, seek time, physical configuration, and  
operating temperature:  
U320 Hard Drive QS:  
(Worldwide)  
(North America)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 18  
QuickSpecs  
Options  
HP ProLiant DL585  
Smart Array 6402/128 Controller  
273915-B21  
273914-B21  
291966-B21  
291967-B21  
Storage Controllers  
Smart Array 6404/256 Controller  
Smart Array 641 Controller  
Smart Array 642 Controller  
NOTE: The Smart Array 641 and 642 Controller must be placed in the 100MHz slots  
only.  
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400  
NOTE: This 256-MB Battery-Backed Cache Module upgrade kit supports the Smart  
Array 6400 series controller only.  
273913-B21  
291969-B21  
351580-B21  
365483-B21  
64 MB Battery Backed Write Cache Enabler  
NOTE: This 64 MB BBWC supports the Smart Array 641 Controller and Smart Array  
642 Controller.  
128MB Battery-Backed Cache Enabler  
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array  
642 Controller.  
DL585 Cable Assembly, SCSI, Ultra3, LVDS  
NOTE: All DL585 models ship standard with the integrated Smart Array 5i Plus  
Controller, which has been designed to deliver maximum performance and availability  
across the internal SCSI Duplex backplane.  
The Ultra3 SCSI cable is required only if the customer chooses to bypass the  
Smart Array 5i Plus Controller and connect slot-based SCSI adapters or RAID  
controllers to the internal SCSI Duplex backplane.  
Two cables are required to maintain the standard, duplexed configuration of  
the backplane.  
One cable is required if the simplex configuration is chosen.  
The backplane is easily configured to simplex mode by means of a simple switch  
duplex to simplex) located on the top of the backplane itself.  
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter  
Ultra320 Expansion Module for SA-6402  
268351-B21  
273911-B21  
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical  
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols  
supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported,  
Cache, RAID support, and additional information:  
(Smart Array 6400 Series)  
(Smart Array 641)  
(Smart Array 642)  
(SCSI Adapter)  
(U320 Adapter)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 19  
QuickSpecs  
Options  
HP ProLiant DL585  
Communications  
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter  
367132-B21  
368169-B21  
353377-B21  
313879-B21  
313881-B21  
290563-B21  
376160-B21  
376227-B21  
376232-B21  
376232-B22  
376232-B23  
HP NC310F PCI-X 1000SX Gigabit Server Adapter  
HP NC1020 PCI 1000T Gigabit Server Adapter  
HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter  
HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter  
HP NC7771 PCI-X 1000T Gigabit Server Adapter  
HP NC570C PCI-X Dual-port 4x Fabric Adapter  
HP 24-Port 4x Fabric Copper Switch  
HP 4x Fabric 1m Copper Cable  
HP 4x Fabric 3m Copper Cable  
HP 4x Fabric 5m Copper Cable  
Management  
Security  
Integrated Lights-Out (iLO) Advanced Pack  
263825-B21  
HP/Atalla AXL600L SSL Accelerator Card for ProLiant Servers  
AXL300 Accelerator PCI Card for ProLiant Servers  
524545-B21  
227933-B21  
Monitors  
Rack-mount Flat Panel Monitors  
TFT5110R Flat Panel Monitor (Carbon)  
281683-B21  
348373-B21  
TFT7210R Rack Mounted 17" Monitor  
NOTE: Monitors larger than 17'' may be too heavy for use in rack systems.  
NOTE: For a complete list of Rack Monitors please view the following URL:  
NOTE: For a complete list of Monitors please view one of the following URL:  
Tape Drives  
NOTE: For complete listing of tape drive offerings see  
For recommended tape drive offerings for this ProLiant server see the following:  
NOTE: Use of a SCSI adapter to connect these devices is required.  
Ultrium Tape Drives - External, Rack-Mount and Array  
HP StorageWorks Ultrium 215 Tape Drive, External (Carbon)  
Q1545A  
HP StorageWorks Ultrium 215 rack-mount (Carbon) - Single drive installed in a 1U  
rack-mount kit  
A7444A  
HP StorageWorks Ultrium 448 Tape Drive, External (Carbonite)  
DW017A  
DW028A  
HP StorageWorks Ultrium 448, Rack-mount (Carbonite) - Single drive installed in a  
1U rack-mount kit  
HP StorageWorks Ultrium 460 Tape Drive, External (Carbon)  
Q1520A  
HP StorageWorks Ultrium 460, Rack-mount (Carbon) - Single drive installed in a 3U  
rack-mount kit  
350546-B21  
HP StorageWorks Ultrium 960 Tape Drive, External (Carbonite)  
Q1539A  
Q1595A  
HP StorageWorks Ultrium 960 Rack-mount (Carbonite) - Single drive installed in a 3U  
rack-mount kit  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 20  
QuickSpecs  
Options  
HP ProLiant DL585  
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for  
additional options such as controllers, media, and other related items:  
(Worldwide)  
(North America)  
(Worldwide)  
(North America)  
For an up-to-date listing of the latest O/S and software support details for HP Ultrium  
DAT Drives - External, Rack-Mount and Array Module  
HP StorageWorks 1U Rack-Mount Kit with one DAT 72 drive (Carbon)  
HP StorageWorks DAT 72 Tape Drive, External (Carbon)  
HP StorageWorks DAT 40 Tape Drive, External (Carbon)  
HP StorageWorks DAT 24 Tape Drive, External (Flint)  
A7443A  
Q1523A  
C5687C  
C1556D  
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and other  
options:  
(Worldwide)  
(North America)  
For an up-to-date listing of the latest O/S and software support details for HP DAT  
Rack-Mount Tape Drive Enclosures  
HP StorageWorks 1U Rack-Mount Kit  
A7445A  
NOTE: The 1U Rack-mount Kit can support up to 2 half-height tape drives and  
compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24,  
DAT40, DAT72, DLT VS 80, Ultrium 215 and Ultrium 448 tape drives.  
HP StorageWorks 3U Rack-Mount Kit  
274338-B21  
NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape  
drives and compatible with multiple Single-Ended and LVD SCSI tape drives including  
DAT 24, DAT 40, DAT 72, , DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, Ultrium  
448, Ultrium 460, and Ultrium 960 Tape Drives.  
HP StorageWorks 5U Rack-Mount Kit  
274339-B21  
NOTE: The 5U Rack-Mount Kit can support up to 4 full-height tape drives and is  
compatible with SDLT 320, Ultrium 230, Ultrium 460, and Ultrium 960 tape drives.  
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional  
information regarding these kits:  
(Worldwide)  
(North America)  
Accessories for 3U & 5U Rack-mount Tape Drive Kits  
LVD Cable Kit, VHDCI/HD68  
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.  
168048-B21  
242381-B21  
LVD Cable Kit, HD68/HD68  
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 21  
QuickSpecs  
Options  
HP ProLiant DL585  
Tape Autoloaders  
DAT Autoloader  
HP StorageWorks DAT 72x6 Tape Autoloader, External (Flint)  
Q1567A  
NOTE: Please see the DAT 72x6 Tape Autoloader QuickSpecs for additional options  
such as host bus adapters, controllers and media:  
(Worldwide)  
(North America)  
HP StorageWorks 1/8 Tape Autoloader  
1/8 Ultrium 460 Tape Autoloader, Tabletop  
1/8 SDLT 320 Tape Autoloader, Tabletop  
1/8 Ultrium 230 Tape Autoloader, Tabletop  
1/8 DLT VS80 Tape Autoloader, Tabletop  
1/8 Tape Autoloader Rackmount Kit  
AA927A  
AA926A  
C9572CB  
C9264CB  
C9268R  
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack  
NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
HP StorageWorks SSL1016 Tape Autoloader  
SSL1016 Ultrium 460 Tape Autoloader  
SSL1016 SDLT 320 Tape Autoloader  
330821-B21  
330816-B21  
NOTE: Please reference the SSL1016 Tape Autoloader QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
HP StorageWorks MSL6000 Tape Library  
Tape Libraries  
Ultrium 960 technology  
MSL6030, 1 drive, 30 slots, Ultrium 960  
AD606A  
AD607A  
AD608A  
AD609A  
AD610A  
AD611A  
MSL6030, 2 drive, 30 slots, Ultrium 960  
MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router  
MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router  
MSL6060, 2 drive, 60 slots, Ultrium 960  
MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router  
SDLT 600 technology  
MSL6026, 1 drive, 26 slots, SDLT 600  
AD582A  
AD583A  
AD584A  
AD585A  
AD587A  
AD588A  
MSL6026, 2 drive, 26 slots, SDLT 600  
MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router  
MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router  
MSL6052, 2 drive, 52 slots, SDLT 600  
MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router  
Ultrium 460 technology  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 22  
QuickSpecs  
Options  
HP ProLiant DL585  
MSL6030, 1 drive, 30 slots, Ultrium 460  
AD598A  
AD599A  
AD600A  
AD601A  
AD603A  
AD604A  
MSL6030, 2 drive, 30 slots, Ultrium 460  
MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router  
MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router  
MSL6060, 2 drive, 60 slot Ultrium 460  
MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router  
NOTE: Please reference the MSL6000 Tape Library QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
HP StorageWorks MSL5026S2 Tape Library  
MSL5026S2, 1 DRV, SDLT320, RM Library  
293472-B22  
293472-B23  
293472-B24  
293472-B25  
MSL5026S2, 2 DRV, SDLT320, RM Library  
MSL5026S2, 1 DRV, SDLT320, Fibre Channel, RM Library  
MSL5026S2, 2 DRV, SDLT320, Fibre Channel, RM Library  
NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
HP StorageWorks MSL5052S2 Tape Library  
MSL5052S2, 2 DRV, SDLT320, RM Library  
293474-B21  
293474-B24  
MSL5052S2, 2 DRV, SDLT320, Fibre Channel, RM Library  
NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
HP StorageWorks MSL5060 Tape Library  
MSL5060, 2 DRV, Ultrium 230, RM Library  
301899-B22  
301899-B23  
MSL5060, 2 DRV, Ultrium 230, Fibre Channel, RM Library  
NOTE: Please reference the MSL5060 Tape Library QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
HP StorageWorks ESL E-Series Tape Libraries  
ESL Extended 712e Tape Library, 0 drive, 712 LTO slots  
ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots  
ESL Extended 322e Tape Library, 0 drive, 322 LTO slots  
ESL Extended 286e Tape Library, 0 drive, 286 SDLT slots  
ESL E-Series Ultrium 960 drive kit  
AA934B  
AA935B  
AA939B  
AA940B  
AD595A  
AA937A  
AA941A  
AA936A  
AA928A  
ESL E Ultrium 460 drive kit  
ESL E-Series Ultrium 460-FC drive kit  
ESL E SDLT 320 drive kit  
ESL E-Series e2400-FC 2G Interface Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 23  
QuickSpecs  
Options  
HP ProLiant DL585  
NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at  
http://www.hp.com/go/automation for additional information needed to create a  
complete solution; reference current compatibility information at  
Magento-Optical  
Jukeboxes  
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes  
300mx, 2 drive, 32 slot jukebox  
C1150M  
C1160M  
C1170M  
600mx, 4 drive, 64 slot jukebox  
700mx, 2 drive, 76 slot jukebox  
NOTE: Please reference the Magneto-Optical Jukebox data sheets at  
http://www.hp.com/go/optical for additional information needed to create a  
complete solution.  
HP StorageWorks 9.1 GB High-end Optical Jukeboxes  
1200mx, 4 drive, 128 slots  
C1104M  
C1105M  
C1111M  
C1107M  
C1110M  
1200mx, 6 drive, 128 slots  
2200mx, 4 drive, 238 slots  
2200mx, 6 drive, 238 slots  
2200mx, 10 drive, 238 slots  
NOTE: Please reference the Magneto-Optical Jukebox data sheets at  
http://www.hp.com/go/optical for additional information needed to create a  
complete solution.  
HP StorageWorks Ultra Density Optical Storage  
1000ux, 2 drive, 32 slot jukebox  
AA965A  
AA966A  
AA968A  
AA967A  
AA969A  
AA970A  
AA973A  
AA971A  
AA972A  
AA974A  
1900ux, 4 drive, 64 slot jukebox  
1900ux, 4 mixed drive, 64 slot jukebox  
2300ux, 2 drive, 76 slot jukebox  
3800ux, 4 drive, 128 slot jukebox  
3800ux, 6 drive, 128 slot jukebox  
7100ux, 4 drive, 238 slot jukebox  
7100ux, 6 drive, 238 slot jukebox  
7100ux, 10 drive, 238 slot jukebox  
7100ux, 6 mixed drive, 238 slot jukebox  
NOTE: Please reference the Magneto-Optical Jukebox data sheets at  
http://www.hp.com/go/optical for additional information needed to create a  
complete solution.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 24  
QuickSpecs  
Options  
HP ProLiant DL585  
ProLiant Cluster Starter Kit  
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see  
364023-B21  
Cluster Options  
the following QuickSpecs at:  
(North America)  
(Worldwide)  
ProLiant Cluster Kit with OpenView Storage Mirroring  
364025-B21  
NOTE: For additional information regarding the ProLiant Cluster Kit with OpenView  
Storage Mirroring please see the following QuickSpecs at:  
(North America)  
(Worldwide)  
ProLiant Cluster HA/F200 for the Entry Level SAN  
364026-B21  
364026-291  
ProLiant Cluster HA/F200 for the Entry Level SAN (Japan)  
NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN  
please see the following QuickSpecs at:  
(North America)  
(Worldwide)  
ProLiant Cluster HA/F500 for the Enterprise SAN  
364024-B21  
305199-B24  
HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0  
and Red Hat EL 3 (2 node license cluster kit)  
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL 3  
(2 node license cluster kit)  
305199-B25  
307754-B24  
307754-B25  
HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and  
Red Hat EL 3 (single license version)  
HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 (single license  
version)  
NOTE: For additional information regarding HP Serviceguard for Linux, please see  
the following QuickSpecs at:  
(North America)  
(Worldwide)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 25  
QuickSpecs  
Options  
HP ProLiant DL585  
External Storage – Rack HP StorageWorks Modular Smart Array 20  
335921-B21  
366172-B21  
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,  
redundant power supplies.  
HP StorageWorks Modular Smart Array 20 Starter Kit  
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,  
redundant power supplies. Includes Smart Array 6402/128 Controller.  
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1"  
Hot Plug Hard Drives.  
HP StorageWorks Modular Smart Array 30 SB  
NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies  
302969-B21  
302970-B21  
HP StorageWorks Modular Smart Array 30 DB  
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies  
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,  
Ultra320 1" Hot Plug Hard Drives.  
Redundant Power Supply 499W  
338296-B21  
287483-B21  
287484-B21  
Ultra320 Dual Bus I/O Module for MSA30  
Ultra320 Single Bus I/O Module for MSA30  
HP StorageWorks  
HP StorageWorks Modular Smart Array 500 Generation 2  
335880-B21  
Modular Smart Array 500 NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for  
additional information including configuration steps and additional options needed  
for a complete solution at:  
(North America)  
(Worldwide)  
HP StorageWorks  
Modular Smart Array  
1500 cs  
Modular Smart Array 1500 Controller Shelf  
AA986A  
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for  
additional options and configuration information at:  
HP StorageWorks  
Modular Smart Array  
1000  
HP StorageWorks Modular Smart Array 1000  
201723-B22  
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options  
and configuration information at  
(North America)  
(Worldwide)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 26  
QuickSpecs  
Options  
HP ProLiant DL585  
StorageWorks Options  
StorageWorks SAN Switch 2/16  
322118-B21  
325888-B21  
325889-B21  
286809-B21  
StorageWorks SAN Switch 2/8-EL Upgrade Kit  
StorageWorks SAN Switch 2/16-EL Upgrade Kit  
StorageWorks Director 2/64  
NOTE: Please see the StorageWorks Director 2/64 QuickSpecs for additional  
information:  
(North America)  
(Worldwide)  
UPS and PDU Power  
Cord Matrix  
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and  
specifications for UPS and PDU units:  
Uninterruptible Power  
Systems – Rack  
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA)  
HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int’l)  
HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan)  
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA)  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA)  
HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan)  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan)  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int’l - detachable cord)  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug)  
204404-001  
204404-B31  
204404-291  
192186-001  
192186-002  
192186-291  
192186-292  
192186-B31  
192186-B32  
192186-B33  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO  
Plug)  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug)  
HP UPS R5500 XR (5000VA, 4500 Watt) High Voltage (NA/JPN, L6-30P)  
HP UPS R5500 XR (6000VA, 5400 Watt) High Voltage (Int'l, IEC-309)  
HP UPS R12000 XR N+x (12000VA, 12000 Watt) (WW-hardwired)  
NOTE: The UPS R12000 XR has a hardwired input and output connection.  
192186-AR1  
326529-D71  
326529-B31  
207552-B22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 27  
QuickSpecs  
Options  
HP ProLiant DL585  
HP Power Distribution  
Unit with Power  
Monitoring  
HP Power Distribution Unit with Power Monitoring Model S2324 - dual input, 3  
phase, 24A (NA/JPN)  
370959-D71  
370960-D71  
370961-D71  
370962-D71  
370963-B31  
370964-B31  
370965-B31  
370966-B31  
HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3  
phase, 24A (NA/JPN)  
HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1  
phase, 40A (NA/JPN)  
HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1  
phase, 40A (NA/JPN)  
HP Power Distribution Unit with Power Monitoring Model S2316 - dual input, 3  
phase, 16A (INTL)  
HP Power Distribution Unit with Power Monitoring Model S1316 - single input, 3  
phase, 16A (INTL)  
HP Power Distribution Unit with Power Monitoring Model S2132 - dual input, 1  
phase, 32A (INTL)  
HP Power Distribution Unit with Power Monitoring Model S1132 - single input, 1  
phase, 32A (INTL)  
Modular Power  
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)  
252663-D71  
(NA, Japan)  
Distribution Units 1U/0U  
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of  
the UPS R3000 XR.  
(Up to 32 outlets)  
NOTE: 1U/0U mounting  
brackets shipped with  
the unit (optimized for  
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)  
(NA, Japan)  
252663-D72  
252663-B31  
252663-B21  
10000 and 9000 series HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC)  
(Int'l)  
racks).  
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)  
(WW)  
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.  
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)  
(WW)  
252663-B24  
NOTE: This PDU has a detachable input power cord and allows for adaptability to  
country specific power requirements. This model may also be used with the high volt  
UPS R3000 XR. For North America, need to order cable PN 340653-001.  
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U  
Modular PDUs) QuickSpecs for additional options including shorter jumper cables  
and country specific power cords:  
(North America)  
(Worldwide)  
HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)  
USB 1.44-MB External Diskette Drive (Carbonite)  
256MB HP Drive Key (USB 2.0)  
DC172B  
DC141B  
PH657A  
USB Options  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 28  
QuickSpecs  
Options  
HP ProLiant DL585  
Custom Builder  
Please see the Enterprise Configurator for configuration assistance at:  
Third Party Rack Kit  
DL585 rack model support:  
287528-B21  
The DL580 G2/585 Third Party rack kit 287528-B21 provides support for any rack,  
square hole or round hole, (including HP Rack System /E and HP Systems), with an  
adjustment range from 23 ½" – 34" deep.  
NOTE: The Third party rack kit is required for round hole racks or for square hole  
racks that do not conform to the adjustment range of the standard rail that ships with  
the server.  
Telco Rack Support  
DL585 rack model support:  
287528-B21  
Support for all 2-post Telco racks requires the Third Party option kit 287528-B21,  
plus an additional option kit from Rack Solutions. The Rack Solutions brackets can be  
Rack Adapter Kit  
332815-B21  
358254-B21  
NOTE: This kit allows HP rack servers to fit in racks that are 24" wide.  
HP 5642 Rack-Unassembled  
HP Rack 5000 Series  
(Graphite Metallic)  
Rack Options for Rack  
5000 Series  
Stabilizer Kit for 5642 Rack (Graphite Carbon)  
NOTE: The stabilizing kit is used to prevent rack from tipping over.  
374493-B21  
374499-B21  
Baying Kit for 5642 Rack (Graphite Carbon)  
NOTE: The baying kit is used to join two or more HP 5642 racks.  
Rack, HP Infrastructure 42U (HV)  
Rack, HP Infrastructure 42U (LV)  
379005-001  
379006-001  
292302-B22  
257415-B21  
257415-B22  
245160-B21  
245160-B23  
245161-B21  
245161-B22  
245161-B23  
245162-B21  
245162-B22  
245162-B23  
245163-B21  
245163-B22  
245163-B23  
HP Rack 10000 Series  
(Graphite Metallic)  
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet  
HP Rack 10842 (42U, 800mm wide) – Pallet  
HP Rack 10842 (42U, 800mm wide) – Shock Pallet  
HP Rack 10647 (47U) – Pallet  
HP Rack 10647 (47U) – Crated  
HP Rack 10642 (42U) – Pallet  
HP Rack 10642 (42U) – Shock Pallet  
HP Rack 10642 (42U) – Crated  
HP Rack 10636 (36U) – Pallet  
HP Rack 10636 (36U) – Shock Pallet  
HP Rack 10636 (36U) – Crated  
HP Rack 10622 (22U) – Pallet  
HP Rack 10622 (22U) – Shock Pallet  
HP Rack 10622 (22U) – Crated  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 29  
QuickSpecs  
Options  
HP ProLiant DL585  
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck  
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,  
VARs and Channels)  
-B23 (crated) used for air shipments of empty racks  
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as  
height, width, depth, weight, and color:  
(Worldwide)  
(North America)  
NOTE: For additional information regarding Rack Cabinets, please see the following  
Rack Options for HP  
Rack 10000 Series  
NOTE: For additional information regarding Rack Options, please see the following  
HP Rack Light Kit (Neon)  
361589-B21  
251960-B21  
246099-B21  
246102-B21  
255486-B21  
221546-xx1  
HP Rack Plinth Kit (Carbon)  
42U Side Panel – Graphite Metallic  
36U Side Panel – Graphite Metallic  
47U Side Panel – Graphite Metallic  
TFT5600 Rack Keyboard Monitor  
Country Code Key (for TFT5600 Rack Keyboard Monitor (PN 221546-xx1))  
XX = 001  
XX = 031  
XX = 041  
XX = 051  
XX = 061  
XX = 071  
XX = 081  
US  
XX = 091  
XX = 101  
XX = 111  
XX = 131  
XX = 181  
XX = 291  
XX = B31  
Norway  
UK  
Sweden/Finland  
Switzerland  
Portugal  
Germany  
France  
Italy  
Belgium  
Spain  
Denmark  
Japan  
International  
1U Rack Keyboard & Drawer (Carbon)  
Country Code Key (for 1U Rack Keyboard & Drawer (PN 257054-xx1))  
257054-xx1  
XX = 001  
XX = 031  
XX = 041  
XX = 051  
XX = 061  
XX = 071  
XX = 081  
US  
XX = 091  
XX = 101  
XX = 111  
XX = 131  
XX = 181  
XX = 291  
XX = B31  
Norway  
UK  
Sweden/Finland  
Switzerland  
Portugal  
Germany  
France  
Italy  
Belgium  
Spain  
Denmark  
Japan  
International  
NOTE: For additional information regarding Rack Options, please see the following  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 30  
QuickSpecs  
Options  
HP ProLiant DL585  
HP KVM Switch Options Server Console Switch (KVM), 0 x 1 x 8 port  
Server Console Switch (KVM), 0 x 2 x 16 port  
IP Console Switch Box (KVM/IP), 1 x 1 x 16  
IP Console Switch Box (KVM/IP), 3 x 1 x 16  
PS/2 Interface Adapter, 8 pack  
336044-B21  
336045-B21  
262585-B21  
262586-B21  
262587-B21  
262588-B21  
336047-B21  
262589-B21  
373035-B21  
263474-B21  
263474-B22  
263474-B23  
263474-B24  
263474-B25  
371302-B21  
371301-A21  
371301-031  
371301-011  
371301-D71  
371730-B21  
371729-B21  
PS/2 Interface Adapter, 1 pack  
CAT5 KVM USB Interface Adapter  
CAT5 KVM Expansion Module  
CAT5 KVM Serial Interface Adapter  
CAT5e Cable 3', 4 pack  
CAT5e Cable 6', 8 pack  
CAT5e Cable 12', 8 pack  
CAT5e Cable 20', 4 pack  
CAT5e Cable 40', 1 pack  
HP 1x4 USB/PS2 KVM Switch, RM (ALL)  
HP 1x4 USB/PS2 KVM Switch, TT, (EURO)  
HP 1x4 USB/PS2 KVM Switch, TT (UK)  
HP 1x4 USB/PS2 KVM Switch, TT, (AUST/NZ)  
HP 1x4 USB/PS2 KVM Switch, TT, (NA/JPN)  
HP 6ft, 2-Pack, PS2 with audio KVM cable  
HP 6ft, 2-Pack, USB with audio KVM cable  
NOTE: For additional information regarding HP KVM Switches and options, please see  
the following URL:  
Service and Support  
Offerings (HP Care Pack  
Services)  
Hardware Services On-site Service  
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years  
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic  
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years  
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic  
U4607A  
U4607E  
U4608A  
U4608E  
6-Hour Call to Repair, On-site Service 7-Day x 24-Hour Coverage, 3 Years  
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years  
U4609A  
U4609E  
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,  
Electronic  
Installation & Start-up Services  
Hardware Installation  
U4617A  
U4617E  
U4618A  
Hardware Installation, Electronic  
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the  
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-  
5pm, M-F, excl. HP holidays.  
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the  
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-  
5pm, M-F, excl. HP holidays, Electronic  
U4618E  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
QuickSpecs  
Options  
HP ProLiant DL585  
Support Plus  
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech  
U4619A  
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP  
holidays.  
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech  
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP  
holidays, Electronic  
U4619E  
Support Plus 24  
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,  
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.  
U4620A  
U4620E  
U6316A  
U6316E  
U9239A  
U9239E  
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,  
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic  
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite,  
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.  
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite,  
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic  
Onsite HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support  
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.  
Onsite HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support  
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic  
NOTE: For more information, customer/resellers can contact:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 32  
QuickSpecs  
Memory  
HP ProLiant DL585  
NOTE: Memory configurations listed do not apply to "Factory Integrated Models."  
HP ProLiant DL585 2P Models  
Standard Memory  
4GB PC3200 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 400MHz or  
2GB PC2100 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 266MHz or  
2GB PC2700 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 333MHz with Advanced ECC  
Rules:  
Must install a minimum of 2 DIMMs in the processor memory board in slot 2  
DIMMs on a processor memory board must be installed in pairs and in bank order  
All DIMMs on a processor memory board must be of the same size (512 MB, 1 GB, or 2 GB)  
Each processor memory board can have different amounts of memory, ex. Processor memory board 2 = (4) 1 GB, Processor  
memory board 1 = (2) 512 MB, Processor memory board 4 = no memory  
PC2700 memory support requires -002 processor board  
333MHz memory performance requires no more than 6 PC2700 DIMMs per processor board; any more will result in the  
memory slowing down to 266MHz  
PC3200 memory, running at 400MHz will be supported on a PC3200-only processor board (012567-001) with 4 DIMM  
slots, resulting in a system max of 32GB with 4 processors  
The following memory options are available from HP:  
1GB of PC2100 DDR SDRAM DIMM Memory Kit (2x512 MB)  
2GB of PC2100 DDR SDRAM DIMM Memory Kit (2x1 GB)  
4GB of PC2100 DDR SDRAM DIMM Memory Kit (2x2 GB)  
1GB of PC2700 DDR SDRAM DIMM Memory (2x512 MB)  
2GB of PC2700 DDR SDRAM DIMM Memory (2x1 GB)  
4GB of PC2700 DDR SDRAM DIMM Memory (2x2 GB)  
2GB of PC3200 DDR SDRAM DIMM Memory (2x1 GB)  
4GB of PC3200 DDR SDRAM DIMM Memory (2x2 GB)  
300679-B21  
300680-B21  
300682-B21  
371047-B21  
371048-B21  
371049-B21  
376639-B21  
379300-B21  
Standard Memory Configuration  
Total Memory = 2 GB  
1
2
3
4
5
6
7
8
Board 1  
Board 2  
512 MB 512 MB  
512 MB 512 MB  
Empty  
Empty  
_
Empty  
Empty  
_
Empty  
Empty  
_
Empty  
Empty  
_
Empty  
Empty  
_
Empty  
Empty  
_
Not  
_
Board 3 (optional)  
Board 4 (optional)  
installed  
Not  
_
_
_
_
_
_
_
installed  
Examples of other optional configurations include, but are not limited to:  
Example #1: Optional Memory Configuration  
Standard Memory plus Optional Processor Memory Boards and Processors  
Total Memory = 32 GB  
1
2
3
4
5
6
7
8
Board 1  
Board 2  
512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB  
512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB  
Board 3 (optional)  
Board 4 (optional)  
2 GB  
1 GB  
2 GB  
1 GB  
2 GB  
1 GB  
2 GB  
1 GB  
2 GB  
1 GB  
2 GB  
1 GB  
2 GB  
1 GB  
2 GB  
1 GB  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 33  
QuickSpecs  
Memory  
HP ProLiant DL585  
Example #2: Maximum Memory Configuration  
Maximum Memory (Standard replaced with Optional Memory and Optional Memory Board)  
Total Memory = 64 GB  
1
2
3
4
5
6
7
8
Board 1  
Board 2  
Board 3 (optional)  
Board 4 (optional)  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
2 GB  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 34  
QuickSpecs  
Storage  
HP ProLiant DL585  
A
B
Diskette Drive eject button  
Ejectable: 24x IDE CD-ROM (Slimline)  
Ejectable: 1.44-MB Diskette Drive (Slimline)  
CD-ROM Drive eject button  
C
D
E
870 Watt (low line or high line) Redundant Hot Plug Power Supply  
870 Watt (low line or high line) Primary Hot Plug Power Supply  
F
0-3  
Wide Ultra3 Drive Cage (Duplex or Simplex configurable). Duplex  
is standard shipping configuration  
Drive Support  
Quantity  
Position  
Supported  
Supported  
Controller  
Ejectable Slim-line Drives  
1.44-MB slim-line Diskette Up to 1  
Drive  
C
Integrated  
IDE slim-line CD-ROM  
Drive  
Up to 1  
B
Integrated IDE  
Integrated IDE  
Slimline DVD-ROM Drive Up to 1  
(8X/24X) Option Kit  
B or C  
Hard Drives  
Ultra320 Hot Pluggable Drives  
Quantity  
Position  
Supported  
Supported  
Controller  
1-inch  
Up to 4  
0-3  
Smart Array 5i Plus Controller (integrated on system board)  
Smart Array 6402/128 Controller  
Smart Array 6404/256 Controller  
Smart Array 641 Controller  
Smart Array 642 Controller  
300-GB 10,000 rpm  
146.8-GB 10,000 rpm  
72.8-GB 10,000 rpm  
148.8-GB 15,000 rpm  
72.8-GB 15,000 rpm  
36.4-GB 15,000 rpm  
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter  
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320  
Smart Array Controller or U320 SCSI HBA to support U320 transfer rates.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 35  
QuickSpecs  
Storage  
HP ProLiant DL585  
External Storage  
Quantity  
Position  
Supported  
Supported  
Host Controller or Adapter  
Modular Smart Array 30 Up to 13  
Family  
External  
Smart Array 6402/128 Controller  
Smart Array 6404/256 Controller  
Smart Array 642 Controller  
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter  
Ultra320 SCSI Adapter  
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate  
OS  
Modular Smart Array  
1000  
Please see the  
External  
Please see the Modular Smart Array 1000 QuickSpecs (URL below)  
for the latest list of supported HBAs  
Modular Smart  
Array 1000  
QuickSpecs  
below to  
determine  
configuration  
requirements  
Modular Smart Array  
1500 cs  
Please see the  
Modular Smart  
Array 1500 cs  
QuickSpecs  
below to  
External  
Please see the Modular Smart Array 1500 cs QuickSpecs (URL  
below) for the latest list of supported HBAs  
determine  
configuration  
requirements  
Maximum Storage Capacity – (External Enclosure Attached)  
Internal  
External  
Total  
1.20 TB (4 x 300 GB Ultra320 SCSI 1" Drives)  
84.00 TB (20 x (14 x 300 GB Ultra320 SCSI 1" Drives))  
85.20 TB  
Tape Drives, Tape Autoloaders, and Tape Libraries  
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:  
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below,  
please see the following:  
Quantity  
Position  
Supported  
Supported Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 36  
QuickSpecs  
Storage  
HP ProLiant DL585  
HP StorageWorks Tape  
Drives, External  
Ultrium 215  
Up to 2  
External  
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter  
Ultrium 230  
Ultrium 448  
Ultrium 460  
DAT 72 Tape Drive  
DAT 40 Tape Drive  
DAT 24 Tape Drive  
HP StorageWorks Tape  
Drives, External  
Ultrium 960  
1
1
External  
External  
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter  
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter  
HP StorageWorks Rack-  
mount Tape Drive  
Enclosures  
1U Rack-Mount Kit  
3U Rack-Mount Kit  
5U Rack-Mount Kit  
HP StorageWorks  
Autoloaders, External  
DAT 72x6 Tape  
Autoloader  
1/8 Tape Autoloader  
SSL1016 Tape  
1 autoloader per  
SCSI channel  
External  
External  
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter  
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter  
Autoloader  
HP StorageWorks Tape  
Libraries, External  
MSL6000 (Ultrium 960 -  
based)  
MSL6000 (SDLT 600-  
based)  
Please reference  
the MSL Tape  
Library  
QuickSpecs to  
determine  
configuration  
requirements  
MSL6000 (Ultrium 460 -  
based)  
MSL5026S2 (SDLT 320-  
based)  
MSL5052S2 (SDLT 320-  
based)  
HP StorageWorks ESL E- Please reference  
External  
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter  
Series Tape Libraries  
ESL 712e  
ESL 630e  
the ESL E-series  
Tape Libraries  
QuickSpecs to  
determine  
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate  
OS  
ESL 322e  
ESL 286e  
configuration  
requirements  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 37  
QuickSpecs  
Power Specifications  
HP ProLiant DL585  
Part Number  
Spare Kit  
384413-001 (870W)  
192201-002 (870W)  
90 to 264  
Operational Input Voltage  
Range (V rms)  
Frequency Range (Nominal)  
(Hz)  
47 to 63 (50/60)  
Nominal Input Voltage (Vrms)  
Max Rated Output Wattage Rating  
Nominal Input Current (A rms)  
100  
800  
11.7  
115  
800  
9.9  
208  
800  
5.2  
220  
800  
4.9  
230  
800  
4.7  
240  
800  
4.5  
Max Rated Input Wattage Rating (Watts)  
Max. Rated VA (Volt-Amp)  
Efficiency (%)  
1143  
1166  
70  
1111  
1134  
72  
1067  
1088  
75  
1067  
1088  
75  
1067  
1088  
75  
1053  
1074  
76  
Power Factor  
Leakage Current (mA)  
Maximum Inrush Current (A peak)  
Maximum Inrush Current duration  
0.98  
.43  
25  
0.98  
.50  
25  
0.98  
.90  
25  
0.98  
.96  
25  
0.98  
1.00  
25  
0.98  
1.04  
25  
20  
20  
20  
20  
20  
20  
System Specifications  
DL585 Fully Configured  
4 processors, 32 memory modules, 4 hard drives, 8 PCI-X expansion cards, 8 hot plug fans, and 2 hot plug power supplies.  
Nominal Input Voltage (Vrms)  
Fully Loaded System Input Wattage (W)  
Fully Loaded System Input Current (A rms)  
Fully Loaded System Thermal (BTU- Hr)  
Fully Loaded System VA (Volt-Amp)  
System Leakage with all power supplies loaded  
(mA)  
100  
954  
10  
3253  
1004  
.87  
115  
928  
8.5  
3163  
976  
1.00  
208  
890  
4.4  
3063  
909  
1.81  
220  
890  
4.1  
3063  
909  
1.91  
230  
890  
4.0  
3063  
909  
2.00  
240  
879  
3.7  
2996  
897  
2.09  
System Inrush Current with all power supplies  
loaded (A)  
50  
50  
50  
50  
50  
50  
Power cord requirements  
Nema 5-15P to IEC320-C19  
Option no./Spare no: 235603-  
001/237457-001  
PDU Jumper Cord IEC320-C19 to  
IEC320-C20  
Option no./Spare no: 295633-  
B21/295508-001  
PDU Jumper Cord IEC320-C14 to  
IEC320-C19  
Option no./Spare no: 291034-  
001/292241-001  
NOTES:  
* To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at  
To drill down to calculators:  
- Click on: "ProLiant Servers"  
- Click on the Server of interest. Example: DL585  
- Click on: "Power Calculator" link (You may need to scroll down to see it.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 38  
QuickSpecs  
Power Specifications  
HP ProLiant DL585  
Power Cords  
Country  
US  
Power Cord Part Number  
295529-001  
295529-011  
295529-021  
295529-031  
295529-291  
AUST  
EURO  
UK  
Japan  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 39  
QuickSpecs  
Technical Specifications  
HP ProLiant DL585  
System Unit Rack  
Chassis Footprint  
(HxWxD)  
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)  
66 lb (29.9 kg)  
Weight  
No hard drives installed,  
one power supply  
Input Requirements  
Rated Input Voltage  
Rated Input Frequency  
Input Power  
100 to 120 VAC/200 to 240 VAC  
50 to 60 Hz  
1135W @ 110 VAC/1125W @ 220 VAC  
Rated Input Current  
12A (100 VAC), 9.8A (120 VAC), 4.9A (220  
VAC)  
Max BTU Rating  
4000 BTU  
Power Specifications  
To review typical system power ratings use the Active Answers Power  
Calculator which is available via the online tool located at URL:  
To drill down to calculators:  
Click on: "ProLiant Servers"  
Click on the Server of interest. Example: DL585  
Click on: "Power Calculator" link (You may need to scroll down to see  
it.)  
Power Supply Output  
Rated Steady-State Power 800W/800W (lowline/highline)  
Power (per power supply)  
Maximum Peak Power  
Operating  
800W/800W (lowline/highline)  
50° to 95° F (10° to 35° C)  
-20° to 140° F (-29° to 60° C)  
-22° to 122° F (-30° to 50° C)  
10% to 70%  
Temperature Range  
Non-operating  
Shipping  
Relative Humidity  
(non-condensing)  
Operating  
Non-operating  
101.7° F (38.7° C)  
5% to 95%  
Maximum Wet Bulb  
Temperature  
Acoustic Noise  
NOTE: Listed are the declared A-weighted sound power levels LWAd and the  
declared average bystander position sound pressure levels LpAm when  
operating in a 23° C ambient environment. Noise emissions were measured  
in accordance with ECMA 74 and declared in accordance with ECMA 109.  
Idle (Fixed Disk Drives  
Spinning)  
L WAd (BELS)  
L pAm (dBA)  
7.3  
55  
Operating Minimum  
(Random Seeks to Fixed  
Disks)  
L WAd (BELS)  
L pAm (dBA)  
7.3  
55  
NOTE: These values apply to 4U rack configuration with the Health Driver  
Fan Control active. Configuration tested included 2 AMD Opteron 2.2 GHz  
processors, 1 15 krpm hard drive, 2 power supplies, 4 memory/IO fans and  
4 CPU fans.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 40  
QuickSpecs  
Technical Specifications  
HP ProLiant DL585  
24X Max (or higher) IDE  
CD-ROM Drive Slim Line  
Disk  
                                                  
                                                   
                                                    
Applicable Disk  
Capacity  
CD-DA, CD-ROM (Mode 1 and 2)  
CD-XA, CD-I (Mode 2, Form 1 and 2)  
Photo CD (Single and Multi-session)  
Mixed Mode (Audio and Data combined)  
540 MB (Mode 1, 12 cm)  
650 MB (Mode 2, 12 cm)  
4.7 x 3.15 in (12 x 8 cm)  
4200 rpm maximum  
0.6 in/15 mm diameter  
1.2 mm  
Diameter  
Rotational Speed  
Center Hole  
Thickness  
Track Pitch  
Mode 1  
1.6 µm  
Block Size  
2,048  
Mode 2  
2,340, 2,336, 1,024 bytes  
2,352 bytes  
CD-DA  
CD-XA  
2,328 bytes  
Interface  
IDE (ATAPI)  
Random  
Access Times (typical)  
100 ms  
Full-Stroke  
Line-Out  
2000 ms  
Audio Output Level  
Data Transfer Rate  
0.7 VRMS at 47 kOhms  
0.6 VRMS at 32 kOhms (maximum volume)  
150 KB/s (sustained 1X)  
2100 to 3600 KB/s  
Headphone  
Sustained  
Burst  
Cache Buffer  
128 KB  
Start-up Time (typical)  
Stop Time  
< 7seconds  
< 4seconds  
Type  
Laser Parameters  
Semiconductor Laser GaA1As  
780 ± 25 nm  
Wave Length  
Divergence Angle  
Output Power  
Temperature  
Humidity  
53.5° ± 1.5°  
0.14 mW  
Operating Conditions  
Dimensions  
41° to 113° F (5° to 45° C)  
10% to 80%  
(HxWxD, maximum)  
Weight  
1.69 x 5.75 x 8.19 in (4.29 x 15 x 20.8 cm)  
2.66 lb (1.2 kg)  
Slim Line CD-RW/DVD- Shipping Dimensions  
13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm)  
5 lb (2.27 kg)  
ROM 24X Combo Drive  
Shipping Weight  
(Multibay)  
Disk  
Applicable Disk  
DVD-ROM  
DVD-R (Read Only)  
2.6 GB/side DVD-RAM (Read Only)  
5.2 GB/side DVD-RAM (Read Only)  
CD-ROM Mode-1 data disc  
CD-ROM Mode-2 data disc  
CD Audio disc  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 41  
QuickSpecs  
Technical Specifications  
HP ProLiant DL585  
CD-Extra  
CD-RW  
CD-R  
CD Text  
PhotoCD  
CD-I (mode 2)  
CD-I Ready  
CD-Bridge  
DVD-ROM  
Capacity  
DVD-SL 4.7 GB/side  
DVD-DL 8.5 GB/side  
Double 9.40 GB/side  
Sided  
DVD-R  
3.95 GB/side  
DVD-RAM  
2.6 GB/side and  
5.2 GB/  
CD-ROM  
Mode-1 650 MB (550 MB)  
Mode-2 742 MB (640 MB)  
2,048 bytes  
Block Size  
DVD  
CD  
2,352 (Mode-0)  
2352, 2340,  
2336, 2048 bytes  
(Mode-1)  
2352, 2340,  
2336, 2048 bytes  
(Mode-2)  
Diameter  
120 mm, 80 mm (with adapter at vertical  
mounting mode)  
Loading Mechanism  
Tray type  
EIDE (ATAPI)  
Random  
Interface  
Access Times (typical)  
DVD-ROM < 120 ms, CD-ROM < 110 ms  
DVD-ROM < 240 ms, CD-ROM < 160 ms  
CD 0.7 Vrms at 47 Kohms Load  
Full-Stroke  
Line-out  
Audio Output Level  
(typical)  
Data Transfer Rate  
(sustained)  
DVD-ROM  
DVD-RAM  
Single Layer  
10.8 MB/sec. Max.  
2.77 MB/sec. Max  
7.2 MB/sec. Max.  
CD-ROM  
Cache Buffer  
Spin-up Time (typical)  
MTBF  
2 MB  
less than 10 seconds  
120,000 Power On Hours  
(POH)  
Ambient Temperature  
Relative Humidity  
Operating  
-22° to 140° F (-30° to 60° C)  
10% to 80%  
Operating  
Storage/Transportation  
(HxWxD, maximum)  
5% to 95%  
Dimensions  
0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm)  
Option Kit Contents  
DVD-ROM drive with installation guide, warranty card, registration card  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 42  
QuickSpecs  
Technical Specifications  
HP ProLiant DL585  
Integrated Lights-Out  
Standard (integrated on  
system board)  
Architecture  
                                                 
                                                  
                                                    
                                                      
                                                      
                                                       
                                                         
                                                           
                                                            
                                                             
                                                              
32-bit PCI-based health and remote management ASIC (Application Specific  
Integrated Circuit)  
Processor  
32-bit RISC processor core running at 66 MHz  
Option firmware upgradeable via flash ROM.  
Upgradeability  
Video Support  
Utilizes the host server's embedded video chip. Supports VGA/SVGA, 640 x  
480 (256 to 16.7M colors), 800 x 600 (256 to 16.7M colors), 1024 x 768  
(256 to 65K colors), 1280 x 1024 (256 colors)  
Interfaces  
Memory  
One Ethernet network connection (10/100 Mb/s)  
2-MB Flash ROM  
8-MB SDRAM  
Operating System  
Support  
Windows 2000 Server  
Windows 2000 Advanced Server  
Red Hat 7.x  
SuSE 7.0  
Client Browser Support  
iLO Standard Features  
Microsoft Internet Explorer 5.5 or later.  
Virtual Text Remote Console  
Virtual Power Button Control  
Dedicated LAN Connectivity  
Automatic IP Configuration via DHCP/DNS/WINS  
Industry Standard 128-bit Secure Sockets Layer (SSL) Security  
IML and iLO Event Logging  
Support for up to 12 user accounts with customizable access privileges  
iLO Advanced Features Virtual Graphical Remote Console  
(optional)  
Virtual Floppy Drive  
Integrated Smart Array 5i Data Compatible with all Yes  
Plus Controller  
Smart Array Controllers  
Instant Upgrades to other Yes  
Smart Array Controllers  
Consistent Software  
Manageability Tools  
Yes  
PCI-X Bus  
64-bit, 100 MHz (integrated on system board)  
PCI-X Peak Data Transfer 800 MB/s  
Rate  
SCSI Protocols Supported Ultra3, Ultra2  
SCSI Peak Data Transfer 160 MB/s per channel  
Rate  
NOTE: For ProLiant servers having TWO internal drive bays on separate SCSI ports: SCSI Peak Data  
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.  
Channels  
2 (only one connected)  
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data  
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.  
SCSI Ports  
0/1  
(external/internal)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 43  
QuickSpecs  
Technical Specifications  
HP ProLiant DL585  
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data  
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.  
Drives Supported  
(maximum)  
2
NOTE: Maximum is the total number of internal drives on each specific ProLiant server.  
Cache  
64 MB Read and/or Write Cache  
Battery-Backed Write  
Cache  
Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB  
RAID Support  
0, 1, 1+0, 5  
Logical Drives (maximum) Maximum = total number of drives  
Online Configuration  
Yes  
Yes  
Online Capacity  
Expansion  
Logical Drive Capacity  
Extension  
Yes  
Yes  
Yes  
Yes  
Online Stripe Size  
Migration  
Online RAID Level  
Migration  
Online Spare Support  
Automatic Data Recovery Yes  
Drive Roaming  
Yes  
No  
Redundant Controllers  
Dual Port NC7782  
Network Interface  
Compatibility  
10/100/1000-T  
IEEE 802.3 10Base-T  
IEEE 802.3ab 1000Base-T  
IEEE 802.3u 100Base-TX  
64-bit/133MHz PCI-X  
10Base-T (Half-Duplex)  
10Base-T (Full-Duplex)  
Data Transfer Method  
Network Transfer Rate  
10 Mb/s  
20 Mb/s  
100Base-TX (Half-Duplex) 100 Mb/s  
100Base-TX (Full-Duplex) 200 Mb/s  
1000Base-TX (Half and  
Full-Duplex)  
2000 Mb/s  
Connector  
RJ-45  
Cable Support  
10Base-T  
Category 3, 4 or 5 UTP up to 328 ft (100 m)  
Category 5 UTP (2 pair); up to 328 ft (100 m)  
10/100/1000Base-T  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 44  
QuickSpecs  
Technical Specifications  
HP ProLiant DL585  
© Copyright 2005 Hewlett-Packard Development Company, L.P.  
The information contained herein is subject to change without notice.  
Microsoft and Windows are US registered trademarks of Microsoft Corporation. AMD, Opteron, and Hyper-Transport are trademarks  
of AMD Corporation in the United States and other countries.  
Unix is a registered trademark of The Open Group.  
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and  
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial  
errors or omissions contained herein.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA - 11902  
Worldwide — Version 29 — May 5, 2005  
Page 45  

Gravely Lawn Mower 201E+05 User Manual
Greenheck Fan Ventilation Hood 474754 User Manual
GVision Computer Monitor L15AX Series User Manual
Harbor Freight Tools Pressure Washer 68333 User Manual
Heat Glo LifeStyle Indoor Fireplace ST 42TVFL IPI User Manual
Honeywell Electric Heater HZ 960 User Manual
Hotpoint Ventilation Hood HTS93G User Manual
Hotpoint Washer FEW10 User Manual
Huey Chiao Headphones HCB42 User Manual
Husqvarna Chainsaw 1153183 95 User Manual