| GS-705N Shear Lock Installation Instruction   Unbalanced air conditioning (stack pressure) can hinder door alignment and must be corrected to help insure positive locking. It   is important to note that the Shear Locks need a regulated 12V DC (or 24VDC) at the lock, and use the highest quality door closer   only. Positive centering door closers are required for all double acting door applicators to help attain consistent dead center   alignment. Also the door latching problems must be corrected prior to installation.   Specifications   Up to 2700 lbs (1226 Kg) in shear.   Holding Force   Power Input   Magnet Assembly   12/24 VDC selectable via jumpers +10%   over voltage is acceptable , under voltage   will reduce holding force.   0.35 A@12 VDC; 0.17 A@24 VDC The unit   does not require initial voltage increase to   operate.   Current Draw   Locking Bolt   Keep Hole   Push-off button   Keep Hole   Finish   Magnet and Armature: Zinc plated   Housing: Black powder coated   Magnet bond sensor output, SPDT rating   1 AMP@30 VDC   Monitoring Output   Armature vertical   adjustment screws   Door Gap   2mm   Armature Assembly   Operating Temper.   -30C to +50C   Connecting Diagram   Magnet bond sensor output   SPDT relay : 1A@30 VDC   Caution:   N.C.   Make sure that the "+" and "-"   wire are connected correctly.   Failure to observe polarity will   result in a short circuit and is   not covered by products   warrant.   COM.   12Vdc   24Vdc   N.O.   Voltage Selection jumpers   Check jumper settings before   connecting the lock to 24 VDC   input power. Damage to the   lock may result from incorrect   jumper settings.   - + - Power   + supply   Control Device   N.C. contact or Access Relay   Dimensions   6 Install the magnet assembly into the door   frame before installation the armature assembly   into the door leaf. The magnet assembly requires   space to run wires, as wall as space for the   recesses portion of the unit. However, make sure   that the position selected for the magnet   assembly leaves enough room on the door to   install the armature assembly.   GS-705N-30   32   30   251   267   Locking Bolt   5.9   30   3.5   Unit: mm   Copyright Gianni Industries, Inc. All Rights Reserved.   P-MU-GS705N-30 Ver. C Publish:2007.07.17   2-1   Download from Www.Somanuals.com. All Manuals Search And Download.   |