Electro Voice Stereo Amplifier CPS211 User Manual

CPS2.11  
High-Efficient, Lightweight  
Two-Channel  
Power Amplifier  
Key Features:  
2 x 1600W/2 Ohms  
High Efficient Class-H Design  
2 U Rack Space  
Detend Rear Level Controls  
Complete Protection Package  
Dynamic Limiter  
Technical Specifications:  
Load Impedance:  
2 Ohms  
4 Ohms  
8 Ohms  
600W  
Maximum Midband Output Power  
(THD = 1%, 1 kHz, Dual Channel):  
1600W  
1100W  
Phoenix Type Inputs  
Rated Output Power  
(THD = 0,1 %, 20 Hz - 20 kHz):  
-
-
900W  
3200W  
78V  
450W  
Barrier Outputs  
Maximum Bridged Output Power  
(THD = 1%, 1 kHz):  
Retrofit Signal Processing Kits  
Remote Power On/Off  
2200W  
Maximum RMS Voltage Swing  
(THD = 1%, 1 kHz):  
Power Bandwidth  
(THD = 1%, 1 kHz, Half Power @ 4 Ohms):  
10 Hz - 60 kHz  
32.0 dB  
General Description:  
Voltage Gain ref. 1 kHz:  
The Electro-Voice® CPS2.11 is from the Contractor Precision  
Series of professional amplifiers. The high efficient Class-H  
design reduces the power dissipation significantly and allows for  
more amplifier channels and output power in a given rack space.  
Input Sensitivity  
(@ Rated Power, 8 Ohms, 1 kHz):  
+5.8 dBu (1.51 Vrms)  
< 0.05%  
THD @ Rated Output Power  
(<0.1%, CPS2T@100V):  
IDE-SMTP (60 Hz, 7 kHz):  
DIM 30 (3.15 kHz, 15 kHz):  
<0.02%  
<0.05%  
The audio performance of the CPS2.11 is state-of-the art and  
fulfills the highest sound expectations in demanding applications  
from concert sound to theater. The CPS2.11 features the same  
complete protection package as all EV Precision Series ampli-  
fiers. Protection against: excessive HF, DC fault, high tempera-  
ture, and Back-EMF as well as turnon delay, peak current and  
inrush current limiters. In addition to the rated output power the  
CPS2.11 provides up to 30% percent headroom for a wide  
dynamic range on music signals. The onboard dynamic limiter  
ensures that the output clipping of the CPS2.11 will not exceed  
a THD of 1% up to an input signal of +21dBu. Detented level  
controls on the rear panel provide precise (1dB-detend) and  
repeatable settings.  
Maximum Input Level:  
+22 dBu (9.76 Vrms)  
<-80 dB  
Crosstalk (ref. 1 kHz, Rated Output Power):  
Frequency Response (+/- 1 dB, ref. 1 kHz):  
Input Impedance Active Balanced:  
Damping Factor @ 1 kHz:  
15 Hz - 40 kHz  
20 kOhms  
>300  
Slew Rate:  
35 V/us  
Signal-to-Noise Ratio (A-Weighted):  
107 dB  
240V, 230V, 220V, 120V, or  
100V; 50 - 60 Hz  
Power Requirements1:  
(Factory Configured)  
Power Consumption:  
820W  
Power Dissipation  
(1/8 Max. Output Power @ 4 Ohms):  
Front panel LEDs indicate signal present, 0 dB, and limit. Female  
XLRs and Phoenix type connectors for inputs and barrier strips  
for outputs provide an easy rack wiring. The power on/off function  
of the CPS2.11 can be remote controlled via a 24V DC source.  
Optional x-over cards for biamp operation (e.g. a 2-way cinema  
system) can be retrofitted.  
396W (1350 BTU/hr)  
Audio Limiters, High Temperature,  
DC, HF, Back-EMF, Peak Current  
Limiters, Inrush Current Limiters,  
Turn-On Delay  
Protection:  
Cooling:  
Front-to-Rear, 3-Stage Fans  
483mm x 88.1mm x 368.8mm  
(19” x 3.5” x 15.22”)  
Dimensions (W x H xD):  
Net Weight:  
8.15 kg (17.96 lbs)  
9.65 kg (21.26 lbs)  
Shipping Weight:  
- Amplifier at rated conditions, both channels driven, 8 ohm loads, unless otherwise specified.  
1 Factory Configured.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Projector LC NB3E User Manual
Electro Voice Stereo Amplifier P 3000 User Manual
Fisher Price Baby Toy V4377 User Manual
Fisher Price Baby Walker L4511 User Manual
Gas Fired Products Electric Heater PTS User Manual
GE Coffeemaker 169086 User Manual
GE Home Security System 45227 1 User Manual
GE Home Security System FTP 1000 User Manual
GE Universal Remote 45600 User Manual
GE Water System FQSVF User Manual