Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
EED4100S
EED4300S
EED4400S
TEDS740P
TEDS840P
TEDX340R
TEDX540R
TEDX640P
22¾"
(57.8cm)
15¼"
(38.74cm)
43³⁄₈"
43³⁄₈"
(110cm)
(110cm)
Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60 Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30 amp
circuit, fused on both sides of the line. Use 10
gauge solid copper wire. A time-delay fuse or circuit
breaker is recommended.
*27¾"
*26"
(66cm)
(70.5cm)
29"
29"
(73.66cm)
(73.66cm)
B
A
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
22¾"
(57.8cm)
43³⁄₈"
43³⁄₈"
(110cm)
(110cm)
13¾"
(34.9cm)
*27¾"
*27¾"
(70.5cm)
(70.5cm)
29"
29"
(73.66cm)
(73.66cm)
C
D
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
* Most installations require a
minimum 5¹⁄₂" (14 cm)
clearance behind the dryer for
the exhaust vent with elbow.
RECESSED AREA AND CLOSET INSTALLATION
3"
(7.6 cm)
14" max.
(35.6cm)
48 in. 2
(310 cm2 )
18"
(45.7 cm)
For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air openings are acceptable.
24 in.2
3"
(7.6 cm)
(155 cm2 )
0"*
(0 cm)
27¾"
(70.5 cm) (14 cm)
5½"
29"
(73.66 cm)
0"*
(0 cm)
0"*
(0 cm)
A. Recessed area
B
C
B. Side view - closet or confined area
C. Closet door with vents
A
EXHAUST VENTING
*Additional spacing recommended
Recommended hood styles
Angled hood style is
acceptable.
B
Number of
90° turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
4"
(10.2 cm)
A
0
1
2
3
4
Rigid metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
Flexible metal
2.5"
4"
(6.4 cm)
Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
(10.2 cm)
4"
(10.2 cm)
Rigid metal
Flexible metal
44 ft (13.4 m) 38 ft (11.6 m)
27 ft (8.2 m) 19 ft (5.8 m)
A. Louvered hood style
B. Box hood style
Rigid metal
Flexible metal
35 ft (10.7 m) 29 ft (8.8 m)
25 ft (7.6 m)
17 ft (5.2 m)
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and turns.
Avoid making 90° turns.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8577187
08-10-06
Download from Www.Somanuals.com. All Manuals Search And Download.
|