| IMI CORNELIUS INC   Installation Manual   ICE/BEVERAGE DISPENSER   MODEL: ENDURO–175 8 VALVE   IMPORTANT:   TO THE INSTALLER.   It is the responsibility of   the Installer to ensure that   the water supply to the   dispensing equipment is   provided with protection   against backflow by an air   gap as defined in   ANSI/ASME A112.1.2-1979;   or an approved vacuum   breaker or other such   method as proved effective   by test.   Water pipe connections   and fixtures directly   connected to a potable   water supply shall be   sized, installed, and   maintained according to   Federal, State, and Local   Codes.   Part No. 620917902INS   Release Date: March 24, 2004   Revision Date: November 18, 2005   Revision: B   THIS DOCUMENT CONTAINS IMPORTANT INFORMATION   This Manual must be read and understood before installing or operating this equipment   PRINTED IN U.S.A   © IMI CORNELIUS INC; 2004–2005   Download from Www.Somanuals.com. All Manuals Search And Download.   SAFETY PRECAUTIONS   This ice dispenser has been specifically designed to provide protection against personal injury and eliminates   contamination of ice. To ensure continued protection and sanitation, observe the following:   ALWAYS: disconnect power to the dispenser before servicing or cleaning.   NEVER: place hands inside of hopper or gate area without disconnecting power to the dispenser.   Agitator rotation occurs automatically when dispenser is energized!   ALWAYS: be sure the removable lid is properly installed to prevent unauthorized access to the hopper interior   and possible contamination of the ice.   ALWAYS: be sure the upper and lower front panels are securely fastened.   ALWAYS: keep area around the dispenser clean of ice cubes.   CAUTION: Dispenser cannot be used with crushed or flaked ice.   Use of bagged ice, which has frozen into large chunks, can void warranty.   The dispenser agitator is not designed to be an ice crusher. Use of large   chunks of ice which “jam up” inside the hopper will cause failure of the agitator   motor and damage to the hopper. If bagged ice is used, it must be carefully and   completely broken into small, cube-sized pieces before filling into the dispenser   hopper.   DESCRIPTION   The “ENDURO” series of ice dispensers solves your ice and beverage service needs in a sanitary, space saving,   economical way. Designed to be manually filled with ice from any remote ice-making source, these dispensers   will dispense cubes (up to 1-1/4 inch in size), cubelets and hard-chipped or cracked ice; and, in addition, several   flavors of post-mix beverages. “BC” units include beverage faucets and a cold plate and are designed to be sup-   plied direct from syrup tanks and carbonator, with no additional cooling required.   IMPORTANT: For dispensing compressed or extruded style ice, an Ice Diverter Kit must be installed on the   dispenser (see Figure 1).   SPECIFICATIONS   Model Descriptions: ED150 –   Ice Storage: 175 lbs   B (Beverage Faucets)   C (Cold Plate)   Z (No Drip Tray)   F (Flavor Option)   Maximum Number of Faucets Available:   8 Built-in Cold Plate: Yes, on BC models only   Electrical: 120/1/60, 3.0 Amps total unit draw   220–240/1/50/60, 2.0 Amps total unit draw   Dimensions: Std unit = 24–1/2 in. Wide X 30–11/16in. Deep X 35–5/8 in.   High   Z–Model = 24–1/2in. Wide X 23–1/16 in. Deep X 35–5/8 in.   High   1 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   INSTALLATION INSTRUCTIONS   IMPORTANT: TO THE INSTALLER.   It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is   provided with protection against backflow by an air gap as defined in ANSI/ASME A112. 1.2-1979; or an   approved vacuum breaker or other such method as proved effective by test.   Water pipe connections and fixtures directly connected to a potable water supply shall be sized,   installed, and maintained according to Federal, State, and Local laws.   1. Locate the dispenser indoors on a level counter top.   A. LEG OPTION   Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit.   The installer must provide flexibility in the product and utility supply to permit shifting the position of the   dispenser sufficiently to clean the area beneath it.   NOTE: Before installing legs, the plastic plugs must be removed.   B. COUNTER MOUNTING   The ice dispenser must be sealed to the counter. The template drawing (see Figure 3) indicates where   openings can be cut in the counter. Locate the desired position for the dispenser, then mark the outline   dimensions on the counter using the template drawings. Cut openings in counter.   Apply a continuous bead of NSF International (NSF) silastic sealant (Dow 732 or equal) approximately   1/4” inside of the unit outline dimensions and around all openings. Then, position the unit on the count-   er within the outline dimensions. All excess sealant must be wiped away immediately.   2. The beverage tubes, drain tube and power cord are routed through the large opening in the bottom of the   unit. See the MOUNTING TEMPLATE (Figure 3) for locating the required clearance opening in the counter   for these utility lines.   3. DRIP TRAY DRAIN ASSEMBLY (see Figure 4): Route the drain tube to an open drain with the end of the   tube above the “flood” level of the drain. Use the tubing, fittings, clamps, and insulation provided with the   Dispenser to assemble the drain. The completed drain line must pitch continuously downward and contain   no “traps” or improper drainage will result.   NOTE: This equipment must be installed with adequate backflow protection to comply with federal,   state, and local codes.   4. Connect the beverage system product tubes as indicated in applicable Flow Diagram Figure 6 or 7. This   work should be done by a qualified service person.   NOTE: See applicable Flow Diagram (see Figure 6 or 7) or Decal on the lower front of the unit for the   location of syrup and water connections.   5. Clean the hopper interior (see CLEANING INSTRUCTIONS in Owner’s Manual).   6. Connect the power cord to a 120 volt, 60 cycle, 3-wire grounded receptacle. For 220–240 Volt International   Units, a 3–wire power cord is provided. An adapter plug for the particular country will need to be provided   by the Installer.   2 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   ICE DIVERTER KIT 02394   NOTE: For dispensing Scotsman, Wilshire, and Hoshizaki compressed ice cubes:   1. Disconnect power to dispenser.   2. Remove Merchandiser from dispenser.   3. Remove ice chute and discard gate restrictor.   4. Install ice diverter on gate mounting plate as shown below.   5. Apply RTV to back surface of ice diverter, to seal to gate mounting plate.   6. Reinstall gasket and ice chute.   7. Reinstall merchandiser and energize unit.   GATE MOUNTING PLATE   STORAGE HOPPER   FLANGE EXTENDS   INTO STORAGE HOP-   PER THROUGH GATE   OPENING   ICE DIVERTER   ICE CHUTE   COVER   APPLY RTV TO   THIS SURFACE TO   SEAL TO HOPPER   GATE MOUNTING   PLATE   10–32 WASHER   GASKET   ICE CHUTE   10–32 NUT   FIGURE 1. ICE DIVERTER KIT   3 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   GATE RESTRICTOR PLATE   CAUTION: Disconnect power to dispenser before installing, removing or   adjusting restrictor.   ADJUSTMENT   INSTALL PLATE   ON STUDS AS   SHOWN   FIGURE 2. GATE RESTRICTOR PLATE   ADJUSTMENT   This plate may be adjusted as shown to reduce or increase the dispensing rate of ice, especially desirable when   using glasses or other containers with small openings. Adjustment can be made by sliding up or down with nuts   loosened, to obtain the desired amount of restriction.   4 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   7/16 DIA.   24 1/2   1 13/16   1 5/16   20 15/16   12   9 18 5/8   21 1/4   OPENING   23 1/16   29 3/4   31 5/16   Z style   REMOVABLE   SINK   7 15/16   8 5/8   3 1/2   17 1/2   RECOMMENDED COUNTER OPENING SIZE   9” X 12” FOR UTILITIES AND BEVERAGE   TUBING. OPENING CAN BE LOCATED ANYWHERE   WITHIN THE SHADED AREA.   FIGURE 3. MOUNTING TEMPLATE   5 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   SOLVENT BOND   HOSE CLAMP   DRIP TRAY DRAIN   FITTING   COUPLING   3/4 SOCKET x 3/4 FPT   BARB ADAPTER   1 BARB x 3/4 MPT   DRAIN LINE   1” I.D. PLASTIC TUBING   (6 FT) WITH INSULATION   FIGURE 4. DRIP TRAY DRAIN ASSEMBLY   6 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   1 2 3 4 FAUCETS VIEWED FROM THIS SIDE   FIGURE 5. FLOW DIAGRAM (BC MODELS WITH EIGHT BEVERAGE FAUCETS)   7 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   1 2 3 4 FAUCETS VIEWED FROM FRONT OF UNIT   FIGURE 6. FLOW DIAGRAM (B MODELS WITH EIGHT BEVERAGE FAUCETS)   8 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   TROUBLESHOOTING   IMPORTANT: Only qualified personnel should service internal components or electrical wiring.   WARNING: If repairs are to be made to a product system, remove quick disconnects from   the applicable product tank, then relieve the system pressure before proceeding. If repairs   are to be made to the CO2 system, stop dispensing, shut off the CO2 supply, then relieve the   system pressure before proceeding. If repairs are to be made to the refrigeration system, make sure   electrical power is disconnected from the unit.   Should your unit fail to operate properly, check that there is power to the unit and that the hopper con-   tains ice. If the unit does not dispense, check the following chart under the appropriate symptoms to aid   in locating the defect.   Trouble   Probable Cause   A. Short circuit in wiring.   BLOWN FUSE OR CIRCUIT BREAKER.   B. Defective gate solenoid.   C. Defective agitator motor.   A. No power.   GATE DOES NOT OPEN. AGITATOR DOES   NOT TURN.   B. Bent depressor plate (does not actuate switch).   C. Defective dispensing switch.   GATE DOES NOT OPEN OR IS SLUGGISH.   AGITATOR TURNS.   A. Defective gate solenoid.   B. Excessive pressure against gate slide.   C. Defective Rectifier.   ICE DISPENSES CONTINUOUSLY.   SLUSHY ICE. WATER IN HOPPER.   A. Stuck or bent depressor plate (does not   release switch).   B. Defective dispensing switch.   C. Improper switch installation.   A. Blocked drain.   B. Unit not level.   C. Poor ice quality due to water quality or   icemaker problems.   D. Improper use of flaked ice.   A. No 24 volt power to faucets.   BEVERAGES DO NOT DISPENSE.   BEVERAGES TOO SWEET.   B. No CO pressure.   2 A. Carbonator not working.   B. No CO pressure in carbonator.   2 C. Faucet brix requires adjusting.   9 620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   Trouble   Probable Cause   A. Empty syrup tank.   BEVERAGE NOT SWEET ENOUGH.   B. Faucet brix requires adjusting.   BEVERAGES NOT COLD (UNITS WITH BUILT-IN   COLD PLATE).   A. Unit standing with no ice in hopper – no ice in   cold plate cabinet.   FLAVOR SYRUPS DO NOT DISPENSE   A. No 24 volt power to PC board.   B. No CO2 pressure.   C. Empty syrup tank.   D. Kinked tubing.   E. Clogged inner nozzle.   F. Defective PC board.   G. Defective harness from keypad.   H. Defective Flow control.   I.   Defective solenoid harness.   J. Defective keypad.   FLAVOR DISPENSES FOR MORE THAN 1 SEC   FLAVOR DISPENSES MORE THAN .5 OZ   A. Dip switch settings on control board incorrect.   B. PC board defective.   C. Defective flow control.   A. Dip switch settings on control board incorrect.   B. Flow control incorrectly set.   C. PC board defective.   D. Defective flow control.   Contact your local syrup or beverage equipment distributor for additional information and troubleshoot-   ing of beverage system.   10   620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   W H T   B R N   R E D   B L U   Y E L   B L K   FIGURE 7. WIRING DIAGRAM (120V)   11   Download from Www.Somanuals.com. All Manuals Search And Download.   620917902INS   G L N TIMER   L2   L1   RECTIFIER   MOTOR HEATER   AGITATOR MOTOR   N.O.   C VEND SWITCH   N.C.   CAPACITOR   GATE   SOLENOID   BALLAST   OPTIONAL LIGHT   STARTER   OPTIONAL   BEVERAGE TRANSFORMER   OPTIONAL FLAVOR VLVS   OPTIONAL ICE LEVEL   PCB   VLV   KEYPAD   BOARD   SOLENOIDS   FIGURE 8. WIRING SCHEMATIC (120V)   12   620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   W H T   B R N   R E D   B L U   Y E L   B L K   FIGURE 9. WIRING DIAGRAM (220/240V UNI)   13   Download from Www.Somanuals.com. All Manuals Search And Download.   620917902INS   220–240V   G L N EMI FILTER   LINE   FILTER   TIMER   L2   L1   RECTIFIER   MOTOR HEATER   POWER SWITCH   VEND SWITCH   AGITATOR MOTOR   N.O.   N.C.   C GATE   SOLENOID   OPTIONAL   BALLAST   OPTIONAL LIGHT   OPTIONAL   STARTER   OPTIONAL   BEVERAGE TRANSFORMER   OPTIONAL FLAVOR VLVS   VLV   SOLENOIDS   KEYPAD   OPTIONAL ICE LEVEL   PCB   BOARD   OPTIONAL   BEVERAGE   VALVES   OPTIONAL   BEVERAGE   VALVES   FIGURE 10 WIRING SCHEMATIC 220/240 V   A C UNITS   FIGURE 10. WIRING SCHEMATIC (220/240V)   14   620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   WARRANTY   IMI Cornelius Inc. warrant that all equipment and parts are free from defects in material and work-   manship under normal use and service. For a copy of the warranty applicable to your Cornelius prod-   uct, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please pro-   vide the equipment model number and the date of purchase.   IMI Cornelius Offices   AUSTRALIA D P.O. 210, D RIVERWOOD, D NSW 2210, AUSTRALIA D (61) 2 533 3122 D FAX (61) 2 534 2166   AUSTRIA D AM LANGEN FELDE 32 D A-1222 D VIENNA, AUSTRIA D (43) 1 233 520 D FAX (43) 1-2335-2930   BELGIUM D BOSKAPELLEI 122 D B-2930 BRAASCHAAT, BELGIUM D (32) 3 664 0552 D FAX (32) 3 665 2307   BRAZIL D RUA ITAOCARA 97 D TOMAS COELHO D RIO DE JANEIRO, BRAZIL D (55) 21 591 7150 D FAX (55) 21 593 1829   ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE, B49 6 EU, ENGLAND D (44) 789 763 101 D FAX (44) 789 763 644   FRANCE D 71 ROUTE DE ST. DENIS D F-95170 DEUIL LA BARRE D PARIS, FRANCE D (33) 1 34 28 6200 D FAX (33) 1 34 28 6201   GERMANY D CARL LEVERKUS STRASSE 15 D D-4018 LANGENFELD, GERMANY D (49) 2173 7930 D FAX (49) 2173 77 438   GREECE D 488 MESSOGION AVENUE D AGIA PARASKEVI D 153 42 D ATHENS, GREECE D (30) 1 600 1073 D FAX (30) 1 601 2491   HONG KONG D 1104 TAIKOTSUI CENTRE D 11-15 KOK CHEUNG ST D TAIKOKTSUE, HONG KONG D (852) 789 9882 D FAX (852) 391 6222   ITALY D VIA PELLIZZARI 11 D 1-20059 D VIMARCATE, ITALY D (39) 39 608 0817 D FAX (39) 39 608 0814   NEW ZEALAND D 20 LANSFORD CRES. D P.O. BOX 19-044 AVONDALE D AUCKLAND 7, NEW ZEALAND D (64) 9 8200 357 D FAX (64) 9 8200 361   SINGAPORE D 16 TUAS STREET D SINGAPORE 2263 D (65) 862 5542 D FAX (65) 862 5604   SPAIN D POLIGONO INDUSTRAIL D RIERA DEL FONOLLAR D E-08830 SANT BOI DE LLOBREGAT D BARCELONA, SPAIN D (34) 3 640 2839 D FAX (34) 3 654 3379   USA D ONE CORNELIUS PLACE D ANOKA, MINNESOTA D (763) 421-6120 D FAX (763) 422-3255   15   620917902INS   Download from Www.Somanuals.com. All Manuals Search And Download.   IMI CORNELIUS INC.   Download from Www.Somanuals.com. All Manuals Search And Download.   |