Cooper Lighting Indoor Furnishings CC10 User Manual

®
COOPER LIGHTING - SURE-LITES  
DIMENSIONS  
DESCRIPTION  
The Contractor’s Choice FasTest™ Ultra  
High-Capacity Emergency Lighting Units  
are an affordable, yet attractive,  
12”  
alternative to standard two-headed  
emergency lighting units. All  
[305mm]  
components snap together to facilitate  
installation in 5 minutes or less. Field  
versatility is not sacrificed for cost, both  
lighting heads offer horizontal and  
vertical adjustability. Moreover, proper  
operation of the transfer circuit and  
emergency lamps can be quickly and  
safely verified by using a convenient  
laser pointer (sold as an accessory). In  
addition, Watchguard EMS self  
21 11/16”  
[551mm]  
19”  
[483mm]  
CC9  
CC10  
CC11  
CC12  
8 7/16”  
[214mm]  
9 7/8”  
[250mm]  
diagnostic system is standard.  
The CC Series Ultra High-Capacity  
Emergency Lighting Units are ideal for  
applications that demand the minimum  
cost but also require maximum  
flexibility, reliability and convenience in  
an attractive unit.  
Contractor’s Choice  
Ultra High Capacity  
Self-Diagnostics  
EMERGENCY LIGHT  
The self-diagnostic unit will  
automatically perform all tests  
required by UL924, and NFPA  
101. The system indicates the  
status of the exit at all times  
using the LED indicator near the  
test switch on the side of the  
unit. A 90 minute battery power  
(emergency mode) simulation  
test will occur randomly once  
every six months.  
• Dual-Voltage Input 120/277  
VAC, 60 Hz  
• Injection-Molded, Color-  
Stable, High-Impact  
UL 94-5V Rated  
Polycarbonate Housing and  
Mounting Plate  
Verify proper operation of the  
transfer circuit and emergency  
lamps with convenient laser  
pointer (sold as an accessory).  
• Designer white textured  
finish  
• Maintenance Free Sealed  
Lead Calcium Battery  
ELECTRICAL RATINGS  
Rated Wattage to 87 1/2% of Rated D.C. Voltage  
Lamp Information  
• Housing Has (8) Locations  
for Mounting of Heads;  
Consult Factory (3 optional  
bottom-mount and 3  
optional top- mount  
locations)  
(3)  
Model  
DC Voltage 1 1/2 Hours  
Remote Capability  
Type  
Wattage Number  
Spacing  
CC9SD  
CC10SD  
CC11SD  
CC12SD  
CC9SDMRT  
CC10SDMRT  
CC11SDMRT  
CC12SDMRT  
12  
12  
12  
12  
12  
12  
12  
12  
160  
200  
240  
300  
160  
200  
240  
300  
136W  
176W  
216W  
276W  
136W  
176W  
216W  
276W  
Incandescent  
Incandescent  
Incandescent  
Incandescent  
MR16  
MR16  
MR16  
MR16  
12 ea.  
12 ea.  
12 ea.  
12 ea.  
12 ea.  
12 ea.  
12 ea.  
12 ea.  
029-132 24'  
029-132 24'  
029-132 24'  
029-132 24'  
029-141 50’  
029-141 50’  
029-141 50’  
029-141 50’  
• Knockouts/Cutouts  
Provided in Housing for  
Surface Conduit  
Attachment  
• Watchguard EMS self  
diagnostic system  
• Remote Photocell Test  
Switch with Automatic  
30-Sec. Test Upon Switch  
Activation  
ORDERING INFORMATION  
SAMPLE NUMBER: CC9SDMRT2142SM  
• Line-Latching, Solid-State  
Voltage Limited Charger,  
Solid-State Switching, Low-  
Voltage Disconnect,  
Options (add as suffix)  
Accessories (order separately)  
Brownout Circuit,  
SQ=Square Head (12W Standard)  
MRT=MR16 Heads (12W Standard)  
Alternate Lamps - Specify quantity,  
lamp number (from Technical  
Information section) and mounting  
location (below), e.g.  
BM=Bottom Mount Heads  
(3 lamp max.)  
Electrical Options  
A=Ammeter  
Model  
Number  
CC9SD  
CC10SD  
CC11SD  
CC12SD  
LASER=Key Chain, Red Laser Pointer  
(activation tested at 30 feet)  
VS1=Polycarbonate Vandal Shield  
VS1WP=Polycarbonate Vandal Shield  
Weather Resistant  
WG3=Wire Guard  
2MSWH=Mounting Shelf  
Overload/Short Circuit  
Protection, Push-Button  
Test Switch/Power Indicator  
Light  
V=Voltmeter  
TDM- Time Daily Monitor  
CSK120=120V Cord Set  
CSK277= 277V Cord Set  
Other Options: Consult Cooper  
Lighting  
CC9SD2134SM319TM219BM  
SM=Side Mount Heads  
• UL 924, Life Safety NFPA  
101, NEC/OSHA, Most  
State and Local Codes  
(2 lamp max.)  
TM=Top Mount Heads (3 lamp max.)  
Representative  
(1) The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum  
ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and  
20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local  
requirements or specific project variables. This is aDgouiwdenlilnoeatdo bfreoumsedWaswawd.eSsiognmaaidn,unaotlsa.scgoumara.nAtelleMofaannyucaolsdeScoemarpclihanAcen. d Download.  
COOPER LIGHTING 619  

Contec Universal Remote RT U50 25S User Manual
Cooper Bussmann Home Security System 9752 User Manual
Crown Boiler Boiler JBF SPD User Manual
Cub Cadet Lawn Mower Z Force S 48 User Manual
Cypress Computer Hardware CY14B102L User Manual
Dixon Lawn Mower ZTR GRIZZLY User Manual
Dynacord Kitchen Entertainment Center ENTERTAINMENT SYSTEM User Manual
Dynaflex Telephone Accessories LCD User Manual
Gefen Network Router DVI 1600HD User Manual
GE Monogram Refrigerator 48 Built In Refrigerators User Manual