I N S T A L L A T I O N I N S T R U C T I O N S
Instrucciones de instalación
Installationsanleitung
Istruzioni di installazione
Installatie-instructies
Instruções de Instalação
Instructions d´installation
Automated Quad Horizontal Door System
This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio or television
communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:
•
•
•
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment to an outlet on a circuit other than that to which the receiver is connected
Consult the dealer or and experienced radio/TV technician for help
CM6QH SERIES
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CM6QH SERIES
System Features and Installation Requirements
Features
Remote Control Activated Lutron Light Dimmer Module
With this dimmer cabinet lighting can be switched on or off and dimmed using the left buttons on the hand held remote control
transmitter.
Obstruction Sensor
The system is equipped with a obstruction sensor. In the event that something would interfere the motion of the doors; the doors
stop, reverse, run a few seconds, and then stop again.
Auxiliary Controls
There is an activator button located on the front of the motor box which will activate the doors.
Status Light
The Status Light on the front of the Motor Box indicates the operating condition of the mechanism. In normal operating conditions,
the status light will be solid green with the doors at rest and will blink a series of green
twice, pause, green twice, pause ..., when the doors are in motion.
Installation Requirements
•
115VAC power at installation site
•
Doors must be made of a non warping material.
TOOLS REQUIRED FOR INSTALLATION
7/16"
PARTS
(A) x1
(with motor)
(B) x1
Lights Off
Scene
1
2
Bri ght
Open
Lights Door
Dim Close
(C) x1
(F) x2
(E) x1
(G) x2
(D) x1
3
Download from Www.Somanuals.com. All Manuals Search And Download.
CM6QH SERIES
Installation Instructions
plate wheel into the track area built into the base. Then tip
the top of the door into the mechanism and engage the
pendant bolts into the slots in the carriages. After hanging
the doors spin the locking nut on the pendant bolts up so
that the nut is finger tight against the bottom of the carriage.
(See figure 3)
INSTALLATION
Installation
1. Secure track to top of cabinet.
2. Align centerline on track with center of cabinet opening, and
keep the front of the track mounting flange flush with front of
the cabinet. (See Firgure 2)
5. Repeat his procedure for the 2 Front doors using the center
carriages.
3. Secure Support Arms to the top of the cabinet.
6. Adjust the doors for plumb by using a 7/16" wrench and
turning the adjustment nut on the pendant bolt. Tightening
the bolt into the door hanger will raise that corner of the
door, loosening the bolt will lower the corner. After all doors
have been adjusted, use one wrench to hold the adjustment
nut and another to tighten the locking nut on the pendant
bolts against the carriage.
Door Hanging Procedure
IMPORTANT ! : Doors should be made of a non-warping
material, not to exceed 1 3/8" in thickness and 50 pounds each.
1. Predrill the tops of the doors as shown with 1/2" clearance
holes for the door hanger pendant bolts.
2. Mount he door hangers to the top of the 4 doors. After
mounting, check to make sure that the pendant bolts can be
freely adjusted in and out of the door hangers. (See figure 3)
3. Mount the guidewheel plates to the bottom of the doors.
(See figure 4)
4. Hang the 2 Rear doors onto the mechanism carriages
located on the underside of the track. Use the carriages
closest to the ends of the track. First engage the guidewheel
IMPORTANT ! : Doors should be adjusted so that they are
even across the top. Do not adjust the doors too high as this will
cause the guidewheel plates to rub and possibly restrict the
movement of the doors. Check to make sure that the front door
guidewheel plates clear the bottom of the rear doors as they
move.
Figure 1
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CM6QH SERIES
Figure 2
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CM6QH SERIES
Installation Instructions
Figure 3
Figure 4
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CM6QH SERIES
1. Plug 115VAC lighting into the back of the Light Dimmer
Module.
2. Plug the other end of Dimmer Module cord into a 115VAC
grounded receptacle on motor assembly.
Install Valance Clips
Three Valance clips are supplied to assist in hanging a valance
in front of the track. (See Figure 5).
CAUTION: The Dimmer is for 120 volt incandescent or
Halogen lamps of at least 25 watts and should not to exceed
300 watts total.
The system also provides the option of creating and saving two
different lighting "scenes". Please refer to the Remote Control
instructions for information on how to configure "scenes".
From Dimmer Module
Figure 6
System Activation
1. Insert plug from the power supply into the jack on the top of
the motor box.
Figure 5
IR Sensor Placement
The placement of the IR sensor can be crucial to proper
operation of the system. A flexible IR sensor is provided to
make it easier to achieve reliable operation.
24VDC Input
In most applications, the IR sensor may be installed on top of
the cabinet. However, tall ceilings and/or dark colored ceilings
can absorb the IR signal. If inconsistent operation is
encountered there are two alternatives.
Top of
Cabinet
•
One, the flexible IR sensor eye can be placed so that it
gives the sensor "line of sight" to the signal from the
remote controller. Often this merely involves placing
the IR sensor so that it peeks up over the top of the
cabinet. It doesn't have to be much, just enough to give
"line of sight".
•
Two, an IR sensor extension cord can be used to
position the IR sensor in the cabinet near to the other
remote controlled units. (For example, near to the VCR
or DVD player)
Install Light Dimmer Module (Optional)
With the dimmer option installed cabinet lighting can be
switched on or off or dimmed using the left buttons on the
systems remote control.
Front of
Cabinet
To install the optional dimmer:
Figure 7
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CM6QH SERIES
Installation Instructions
2. Plug Powercord into 115VAC outlet.
box for approxamatly 13 seconds and then release it when the
Status Light flashes quickly red, green, red, green, red, green.
IMPORTANT ! : A quality surge protection device is
recommended.
Activator Button
3. Make sure nothing is obstructing movement of doors,
4. Press and release the Activator Button on the front of the
Motor Box or the "Close Door button on the Remote Control.
(The doors should travel to the fully closed position)
Activator
Figure 10
The controller will then be in “Learn Mode” (The door will move
for 3 seconds, stop for 10 seconds, and when it starts moving
again it will be in it’s “Learn Mode”).
When put into “Learn Mode” the mechanism runs back and
forth several times and measures it’s environment, such as
open and closed locations etc., and then stops and remembers
these learned measurements, so that next time the system runs
it knows where to start and stop.
Figure 8
5. Press the "Open Door" button on the Remote Control.
NOTE: If a different travel distance is required see "Door
Travel Adjustment below.
ADJUSTMENTS
Status Light Codes
There is a light on the front of the mechanism motor box that
will tell through its pattern of flashes and colors what the
mechanism is doing.
Adjust Door Travel Distance
To adjust door travel distance:
1. Press and hold the activator button on the front of the motor
box for 13 seconds.
The Status Light on the front of the motor box will begin to blink
alternately red and green. When this starts to happen release
the Activator Button. When put into "Learn Moden the system
runs back and forth several times and measures it's
environment, such as open and closed locations etc. The
system will then stop and remember these learned
measurements.
Status Indicator
Activator
Figure 11
Normal Doors At Rest - The Status Light will be on steady
green.
Normal Run Motion of Doors - The Status Light will flash in
groups of 2 green followed by a pause. In normal run motion
the doors on the system have a variable speed. The doors will
start slowly, accelerate to a fast speed, and then slow down
before coming to a stop.
Figure 9
Doors Obstructed - The Status Light will flash in groups of 3
red followed by a pause. If the doors meet an obstruction they
will sense the obstruction, stop momentarily, and move in the
opposite direction for a few seconds. ---- Remove the
obstruction and then activate the doors. They should return to
normal run motion.
System Controls and Indicators
Learn Mode
The CM6SV system has no limit switches. The system uses an
encoder on the motor to collect data and send it to the micro
processor’s memory. The software "learns" about its
environment (speed, time duration, stop points, etc.) during the
initial setup of the unit and retains that information until
requested to "relearn" its environment.
Doors Obstructed Both Ways - The Status Light will flash in
groups of 4 red followed by a pause. Similar to Doors
Obstructed but doors are prevented from moving in either
direction. ---- Remove the obstruction and then activate the
doors. They should return to normal run motion.
The unit is shipped pre-set from the factory and will then
continually adjusts to it’s enviornment on each activation.
Travel Too Far - The Status Light will flash in groups of 5 red
followed by a pause. The motor is running but the doors are
not moving. ---- Has the motor box been uncoupled from the
If for some reason you want to place the system into “Learn
Mode” (such as to stop at other than its normal stop points),
Press and hold the red activator button on the front of the motor
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CM6QH SERIES
track, or is the motor box bent, causing it to become uncoupled
from the track?
Control Input
Power Loss - The Status Light will be on solid red. ---- There
has been a power loss (due to an electrical storm, etc.). When
next activated the doors will move at a slow speed to their full
closed position. If the doors are already closed they will not
move. The Status Light will return to solid green and the doors
are ready for normal activation.
Optional Control Input Connections
Control Input- 8 position RJ 45 modular phone jack
Discrete control for use with 3rd party control.
Figure 12
NOTE: Making a momentary dry contact closure between the
common and the open, closed, stop, or sequence will
activate the system in that mode.
•
•
Position 8- Open
Position 7- Stop
IR Receiver “Eye” input for Eubank, Inc. supplied external IR
reciever only.
•
•
Position 6 - V out
Position 5 - Vcc, 5v
Radio Power for external RF reciever only.
Position 4 - 24 VDC
Sequence control for use with 3rd party control.
•
•
•
Position 3 - Sequence- Open, Stop, Close, Stop
Position 2 - Common
Discrete control for use with 3rd party control.
Position 1 - Close
Control Input on Front of Motor Box
•
Control Input on Front of Motor Box
Figure 13
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CM6QH SERIES
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Asia Pacific
A
Room 30I, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA. Post Code: 518112
8820-000021
¤2007 Chief Manufacturing
03/07
P
F
+86-755-8996 9226 ; 8996 9236 ; 8996 9220
+86-755-8996 9217
Download from Www.Somanuals.com. All Manuals Search And Download.
|