BRK electronic Home Safety Product EL52 User Manual

USER’S MANUAL  
NYLON/STEEL FIRE ESCAPE LADDER  
MODEL EL52  
This nylon/steel Fire Escape Ladder is easy to use,  
and provides a reliable means of escape through  
a second floor window during a home fire.  
FEATURES AND BENEFITS  
• For use in two-story homes  
• Strong nylon construction  
• Fully assembled, ready to use  
• Slip-resistant epoxy coated rungs  
• Large hooks secure easily to windowsills  
• Steel rung stabilizers on all rungs  
• Ladder complies with the ASTM Standard F 2175-02.  
375 lb. Ladder load rating  
• Ladder is 14 feet (4.3 meters) in length.  
• Read instructions for use immediately upon purchase.  
• Close doors before opening any windows to prevent fire from being drawn into the room.  
• Keep body close to ladder.  
• Unless absolutely necessary, do not carry a child when using this ladder.  
• Do not carry pets or miscellaneous objects when using this ladder.  
• Instruct family members to use this portable escape ladder only when the primary escape path  
(that is, the main exit) is blocked or unsafe to use.  
• This portable escape ladder is not a toy or recreational device. Instruct children that the ladder  
is to be used only in an emergency.  
• For use only in windows that are structurally safe for the intended load.  
• Not recommended for use with storm windows or other windows that do not open to the  
recommended minimum dimensions [20 inches (51 cm) wide and 32 inches (81 cm) high].  
• Do not use above a 2 story height.  
• Do not attempt to deploy the ladder from windows that are obstructed by furniture, radiators,  
air conditioning units, or security devices such as grilles or bars (without inside release  
mechanisms).  
• Do not attempt to deploy the ladder into flames.  
• Check for outside obstructions such as electric lines, telephone wires, or fences.  
• Do not attempt to use the ladder if the windowsill does not meet the size range specified.  
The windowsill width should be between a minimum of 6 inches (15 cm) and a maximum of  
10 inches (25 cm).  
• Always plan and practice drills to ensure that occupants are familiar enough for proper use.  
• This ladder is intended to supplement (not replace) the more important fire protection principles  
of fire drills, emergency evacuation plans, smoke alarms, fire extinguishers, etc.  
• This ladder should be periodically inspected for damage, loosening of any items, or significant  
deterioration of the materials of construction.  
• This ladder is designed for use by one person at a time.  
• Store the ladder in a convenient location near the exit window; for example, under a bed, in a  
closet, etc.  
All Rights Reserved. © 2003 BRK Brands, Inc.  
4BRK Brands, Inc., 3901 Liberty Steret Road, Aurora, IL 60504-8122  
M08-0041-001 07/04  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Securing the Ladder After Use  
How to Use in a Fire Emergency  
1. Lay the box on the floor with the lid folded open.  
This fire escape ladder is not a toy or recreational device.  
Use it only in a fire emergency.  
2. Stretch the ladder out  
on the floor, with the  
rung standoffs facing  
up towards you placing  
the rungs as close as  
possible next to each  
other.  
It is strongly recommended that children and elderly adults  
be assisted by an adult if at all possible when using this  
ladder in a fire emergency.  
THIS LADDER IS DESIGNED FOR USE BY ONE PERSON AT  
A TIME.  
1. Before you open the window, close the door leading out of  
the room to prevent the fire from being drawn into the  
room.  
3. Use the plastic strap  
(attached to the last  
rung) to wrap and  
secure the rungs.  
This will minimize the  
chance of the ladder  
becoming tangled  
when you remove it  
from the box in an  
emergency.  
2. Remove the ladder from  
the box and unfold sill  
hooks so the folding  
crosspiece is straight and  
positioned towards you.  
4. Lay the rungs,  
wrapped with the  
plastic wrap, in the  
box with the stand-  
offs facing upward.  
Place the folded sill  
hooks on top of the  
rungs, between the  
standoffs.  
3. Place the sill hooks firmly over the windowsill and pull the  
release strap to deploy the ladder.  
5. Store the escape ladder in an accessible location.  
Be sure nothing blocks your access to the ladder.  
4. Exit carefully through the  
window and place your feet  
on the first rung. Hold onto  
the window frame until your  
weight is evenly distributed  
on the ladder. Climb down,  
keeping your body close to  
the ladder.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
What Fire Escape Ladders Cannot Do  
Limited Warranty  
• This fire escape ladder is NOT a means of protection  
against fire. It will not warn or alert you to a fire or of  
any other type of emergency. It is intended to be used  
as an alternate escape means in a fire emergency only.  
BRK Brands, Inc., ("BRK") the maker of First Alert® brand  
products warrants that for a period of six years from the date of  
purchase, this product will be free from defects in material and  
workmanship. BRK, at its option, will repair or replace this  
product or any component of the product found to be defective  
during the warranty period. Replacement will be made with a  
new or remanufactured product or component. If the product  
is no longer available, replacement may be made with a similar  
product of equal or greater value. This is your exclusive  
warranty.  
• This fire escape ladder is NOT intended to be the  
main exit for escape in an emergency. Instruct family  
members to use the fire escape ladder as a last resort,  
ONLY when their main exit is blocked, not accessible,  
or unsafe to use.  
• This fire escape ladder is NOT a toy or recreational  
device. It is intended to be used as a supplemental  
emergency escape device ONLY. Instruct children not  
to use this fire escape ladder for any reason, except  
in an emergency.  
This warranty is valid for the original retail purchaser from the  
date of initial retail purchase and is not transferable. Keep the  
original sales receipt. Proof of purchase is required to obtain  
warranty performance. BRK dealers, service centers, or retail  
stores selling BRK products do not have the right to alter,  
modify or any way change the terms and conditions of this  
warranty.  
• DO NOT carry any pets or other objects when using  
the ladder.  
• Unless absolutely necessary, do not carry a child when  
using this ladder.  
This warranty does not cover normal wear of parts or damage  
resulting from any of the following: negligent use or misuse  
of the product, use contrary to the operating instructions,  
disassembly, repair or alteration by anyone other than BRK  
or an authorized service center. Further, the warranty does  
not cover Acts of God, such as fire, flood, hurricanes and  
tornadoes.  
• This portable fire escape ladder does not meet your  
local codes as a primary means of exit from multi-family  
dwellings. It is not intended to replace fire escapes in  
multi-family residences, institutions, or rental properties.  
This ladder is intended for use as a means of escape  
from residential buildings, and may supplement the  
primary means of exit required by codes and other  
local regulations.  
BRK shall not be liable for any incidental or consequential  
damages caused by the breach of any express or implied  
warranty. Except to the extent prohibited by applicable law,  
any implied warranty of merchantability or fitness for a particular  
purpose is limited in duration to the duration of the above  
warranty. Some states, provinces or jurisdictions do not allow  
the exclusion or limitation of incidental or consequential  
damages or limitations on how long an implied warranty lasts,  
so the above limitations or exclusion may not apply to you. This  
warranty gives you specific legal rights, and you may also have  
other rights that vary from state to state or province to province.  
• This fire escape ladder is NOT intended for use from  
rooms above a second-floor level. DO NOT use from  
rooms above a second-floor height. The ladder is  
14 feet (4.3 meters) long and is NOT intended for  
escape from rooms with windowsills higher than  
16 feet (4.9 meters) from the ground.  
• This fire escape ladder is NOT intended to be hooked  
onto gutters, siding, or any other interior or exterior  
fixture. It is ONLY intended to be hooked to windowsills.  
How to Obtain Warranty Service  
Service: If service is required, do not return the product to  
your retailer. In order to obtain warranty service, contact the  
Consumer Affairs Division at 1-800-323-9005, 7:30 AM–5:00 PM  
Central Standard Time, Monday through Friday. To assist us  
in serving you, please have the model number and date of  
purchase available when calling.  
303 Nelson Avenue, Neosho, MO 64850-8806  
First Alert® is a registered trademark of the First Alert Trust.  
M08-0041-001 07/04  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bissell Vacuum Cleaner 88D6 User Manual
Black Box Network Cables BLACK BOXNETWORK SERVICES User Manual
Blaupunkt Video Game Sound System LS 162e User Manual
Bolens Automobile Accessories 19200 User Manual
Broil King Food Warmer MLB CSLP4 User Manual
Brother Fax Machine MFC 730 User Manual
CDA Beverage Dispenser BVB4 User Manual
Charnwood Fire Pit FIREPIT User Manual
Christie Digital Systems Projector LU77 User Manual
Christie Digital Systems Projector LW25U User Manual