AXC
In-Line Duuct FFaannss
Download from Www.Somanuals.com. All Manuals Search And Download.
AXC In-Line Duct Fans
Applications
The versatility of the AXC fan is endless. The most common uses are bathroom exhaust, range hood exhaust and duct boosting.
Bathroom Exhaust
AXC in-line duct fans are the strongest and quietest bathroom fans available today. These fans allow the exhaust of multiple vents or
bathrooms with one fan. They are user friendly, easy to install, and can be located directly over a shower.
Range Hood Exhaust
AXC in-line duct fans can be used as a principle exhaust fan, or as a booster fan to improve the efficiency of an existing residential
range hood. These fans can be variable speed controlled by using an independent speed controller, or by tying into an existing
range hood controller. The heavy gauge housing, with epoxy coating inside and out, provides a rugged fan with superior corrosion
protection.
Duct Boosting
AXC in-line duct fans can solve many air moving problems. They are designed to boost airflow through long or complex duct runs,
and provide ideal solutions for areas that are hard to heat or cool.
Other applications include:
• Residential kitchen exhaust
• Conference room exhaust
• Principal exhaust fan
• Cafeteria exhaust
• Computer rooms
• General ventilation
• Hot tub / sauna exhaust
• Health care facilities
• Hair & nail salons
• Warm air transfer
• Humidity and moisture removal
• Powered make-up air
• Spot cooling
• Equipment cooling
• HRV/ERV boosting
Simplify it with a Kit
At Continental Fan, we know that you have specific needs! That is why we offer a variety of kits for different ventilation applications!
Not sure which kit is right for your application? Call one of our qualified technical support personnel; we are happy to help!
Available Accessories
A full range of accessories is available to suit each custom application.
Digital Timers
Dehumidistats
Pressure Switchs
Roof Caps
Wall Caps
Speed
Controls
Supply &
Exhaust Grilles
Backdraft
Dampers
Mounting
Clamps
Flexible
Duct
3
Download from Www.Somanuals.com. All Manuals Search And Download.
How do I know which fan is best suited for my application?
As previously summarized, there are numerous applications where ventilation is required. Whether it is for residential or
commercial applications, it is imperative that the proper amount of airflow be calculated.
Residential
One of our qualified technical support personnel would be happy to assist in selecting a fan for your residential ventilating needs.
If you would like to inform yourself further, HVI, the Home Ventilating Institute provides ventilating guidelines for consumers. For
Commercial
For an application that is commercial or very specific in nature, you may want to enlist an HVAC contractor. For a list of
contractors near you, consult the yellow pages.
Performance Data
Dimensional Data
CUBIC FEET PER MINUTE
D
d
(in.)
a
(in.)
B
(in.)
WT
(lbs)
1
1
3
1
3
1
1
MODEL
WATTS AMPS RPM dBA* 0”SP /8”SP /4”SP /8”SP /2”SP /4”SP 1”SP 1 /4”SP1 /2”SP 2”SP 3”SP
MODEL
(in.)
AXC100A
AXC100B
AXC125A
AXC125B
AXC150A
AXC150B
AXC200A
AXC200B
AXC250
55 0.57 1750 44
85 0.69 2400 54
62 0.58 1650 36
85 0.70 2350 53
80 0.75 2500 54
72 0.73 2580 55
72 0.72 2550 56
160 1.52 2700 60
250 1.94 2650 63
190 2.07 2650 68
106
99
93
87
80
68 55
39
66
AXC100A
AXC100B
AXC125A
AXC125B
AXC150A
AXC150B
AXC200A
AXC200B
AXC250
9.5
3.9
1.0
8.3
6.5
152 146 139 131 124 106 82
33
9.5
9.5
3.9
4.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.5
1.5
8.3
8.3
6.5
6.5
159 127 100
82
68
34
212 185 162 145 128
79 32
9.5
4.8
8.3
6.5
247 225 202 178 161 132 92
309 271 237 202 171 132 107
50
88
9.5
5.8
8.3
6.5
15
56
13.2
13.2
13.2
13.2
15.9
15.9
19.0
19.0
5.8
9.1
11.0
11.0
11.0
11.0
18.0
20.0
26.0
31.0
418 397 366 339 306 233 174 110
7.8
9.1
636 618 557 521 494 412 353 271 190 78
695 659 610 541 500 359 279 197 125 41
865 824 765 736 677 553 459 365 283 124
7.8
9.1
9.8
9.1
AXC300A
AXC300B
AXC355A
AXC355B
AXC300A
AXC300B
AXC355A
AXC355B
11.8
11.8
14.0
14.0
11.8
11.8
15.7
15.7
345 2.78 2765 74 1198 1165 1052 981 945 796 615 453 363 178
334 2.88 1360 57 1325 1220 1105 985 860 688 550 400 238
65
830 7.81 2900 77 1400 1375 1360 1335 1285 1220 1135 1075 1000 880 675
* The sound pressure level dBA has been measured in accordance with the
international standard ISO 3744. It is the average free field value taken at a
radius of 1 meter from the fan, fully ducted, and located above a reflecting
plane.
At present, there is no standard for sone level testing of remote mounted fans.
Sound levels can be affected by the type of duct used, size of duct, distance of
the fan from the interior grille/diffuser, and other pertinent factors. Sound tests
that do not consider these factors are irrelevant.
R
Note: AXC models 100A through 300B are UL and CSA listed products.
Note: AXC models 355A and 355B are CSA listed to both US and Canadian standards.
R
Distributed By:
Continental Fan Manufacturing Inc.
203 Eggert Road
Aeroflo Inc.
12–205 Matheson Blvd. East
Mississauga, Ontario, Canada L4Z 3E3
Tel: 905-890-6192 Toll: 800-779-4021
Fax: 905-890-6193
Buffalo, NY 14215
Tel: 716-842-0670 Toll: 800-779-4021
Fax: 716-842-0611