MARCH 2000
IC050C
IC171C
RS422/485 Serial Interface Plus
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
CUSTOMER
SUPPORT
Web site: www.blackbox.com
•
E-mail: [email protected]
INFORMATION
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes
de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para
referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de
operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,
etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales
que sean recomendados por el fabricante.
7. El parato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más
allá a lo descrito en las instrucciones de operación. Todo otro servicio
deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no
interfiera su uso. La colocación del aparato eléctrico sobre una cama,
sofá, alfombra o superficie similar puede bloquea la ventilación, no se
debe colocar en libreros o gabinetes que impidan el flujo de aire por los
orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de
calor como radiadores, registros de calor, estufas u otros aparatos
(incluyendo amplificadores) que producen calor.
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo
del tipo descrito en el instructivo de operación, o como se indique en el
aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,
poniendo particular atención a los contactos y receptáculos donde salen
del aparato.
14. El equio eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no
sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean
derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del
aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su
desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
Contents
Chapter
Page
1. Specifications....................................................................................................1
2. Introduction.....................................................................................................2
2.1 Overview..................................................................................................2
2.2 What’s Included......................................................................................2
2.3 Features...................................................................................................3
2.4 Technical Description............................................................................3
3. Address Selection.............................................................................................6
4. Option Selection..............................................................................................8
5. Installation......................................................................................................15
5.1 Software Installation .............................................................................15
5.1.1 Windows 3.1x...............................................................................15
5.1.2 Windows 95/98 ..........................................................................15
5.1.3 Windows 98..................................................................................15
5.2 Hardware Installation ...........................................................................15
6. Windows 3.1 Installation................................................................................16
7. Troubleshooting ............................................................................................19
Appendix: Circuit-Board Design.......................................................................23
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Specifications
1. Specifications
Number of Ports — Single RS-485/422
Speed — IC050C: 115.2 Kbps; IC171C: 460.8 kbps and higher
RS-485 Operation — 2- or 4-wire
Connectors — DB25P
Maximum Distance — Up to 5000 ft. (1524 m)
Communications Chip — IC050C: 16550 UART; IC171C: 16950 UART
MTBF — >150,000 hours
MTTR — <0.25 hours
Materials — Boards are solder mask over bare copper or tin nickel
Operating Temperature — 32° to 122°F (0° to 50°C)
Storage Temperature — -4° to 158°F (-20° to 70°C)
Humidity — 0 to 90% relative humidity, noncondensing
Power — +5 VDC @ 160 mA
1
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
2. Introduction
2.1 Overview
The RS422/485 Serial Interface Plus is an easy-to-use RS-485 interface for
your PC. It incorporates unique hardware circuitry that enables the RS-485
interface to appear to be an RS-232 interface, requiring no additional
software drivers.
Previous RS-485 interfaces required the software to “turn on” RTS to transmit
and then “turn off” RTS at the end of the character. This required overhead
and special interrupt processing. Newer operating systems such as
®
Windows™, Windows NT™, OS/2 , and other multi-tasking operating systems
typically will not allow the user access to the low-level registers of the UART
chip without writing a specialized driver. Since the RS422/485 Serial Interface
Plus emulates an RS-232 port, installation is as easy as picking an address and
interrupt level.
The README file on the serial utility disk contains information about the
latest changes and revisions. To view this file, insert the diskette into drive A
or B and type A:TYPE READ.ME|MORE [ENTER]or B:TYPE
READ.ME|MORE [ENTER].
2.2 What’s Included
Your Serial Interface Plus should come with the following items. If any of
these items are missing or damaged, contact Black Box.
(1) RS422/485 Serial Interface Plus card
(2) 3.5" serial utility diskettes
This manual
2
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 2: Introduction
2.3 Features
Listed below are the special features your Serial Interface Plus offers.
• Single-channel RS-485/422 adapter for Windows, OS/2, Windows NT,
and DOS communications.
• Addressable as COM1: through COM4: or twelve other pre-selected
address options.
• Automatic RS-485 protocol control allows card to appear to be RS-232;
therefore, no special drivers or additional software is required.
• “PAL” allows for unique OEM address selection.
• Individually selectable addresses and extended AT interrupts allow
for seamless integration into OS/2 and Windows systems.
• IRQs 2–7, 10–12, and 15 supported.
• IRQs can be shared or individually set for each port.
• 16-bit address decode allows for easy integration.
• Selectable termination, echo mode, and two- and four-wire operation.
2.4 Technical Description
The RS422/485 Serial Interface Plus (IC050C) provides one RS-422/485
serial port utilizing the 16550 UART. This chip features programmable baud
rate, data format, and interrupt control, and a 16-byte input and output FIFO.
The IC171C uses a 16950 UART, and has a 128-byte FIFO.
RS-422
RS-422, unlike RS-232, is a differential interface that defines voltage levels,
and driver/receiver electrical specifications. On a differential interface, logic
levels are defined by the difference in voltage between a pair of outputs or
inputs. In contrast, a single-ended interface, for example RS-232, defines the
logic levels as the difference in voltage between a single signal and a common
ground connection. Differential interfaces are typically more immune to
noise or voltage spikes that may occur on the communication lines.
Differential interfaces also have greater drive capabilities that allow for longer
cable lengths. RS-422 is rated up to 10 Mbps and can have cabling 5000 feet
(1524 m) long. RS-422 also defines driver and receiver electrical
characteristics that will allow 1 driver and up to 32 receivers on the line at
once. RS-422 signal levels range from 0 to +5 volts. RS-422 does not define
a physical connector.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
RS-530 and RS-449
RS-530 and RS-449 (EIA-530 and EIA-449) are similar to RS-422 and
RS-485 in the fact that they are differential interfaces, but these two standards
provide a specified pin-out that defines a full set of modem control signals
that can be used for regulating flow control and line status. RS-449 is defined
on a standard 37-pin D sub-connector, while RS-530 is backward-compatible
and is replacing RS-449. RS-530 is defined on a 25-pin D sub-connector.
TX+
TX-
RX+
RX-
RX+
RX-
TX+
TX-
Figure 2-1. RS-422/530 Connection.
RS-485
This interface is very similar to RS-422 is several ways. RS-485 is a differential
interface that allows cable lengths up to 5000 feet (1524 m) and data rates up
to 10 Mbps. The signal levels for RS-485 are the same as those defined by RS-
422. RS-485 has electrical characteristics that allow for
32 drivers and 32 receivers to be connected to one line.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 2: Introduction
This interface is ideal for multi-drop or network environments. The RS-485
tri-state driver (not dual-state) will allow the electrical presence of the driver
to be removed from the line. The driver is in a tri-state or high-impedance
condition when not active. Only one driver may be active at a time and the
other driver(s) must be tri-stated.
Some communication software packages refer to RS-485 as RTS enable or
RTS block mode transfer.
RS-485 can be cabled in two ways, 2- and 4-wire mode. Two-wire mode does
not allow for full-duplex communication. It requires that data be transferred
in only one direction at a time and the two transmit pins be connected to the
two receive pins (Tx+ to Rx+ and Tx- to Rx-). Four-wire mode will allow full-
duplex data transfers. RS-485 does not define a connector pin-out, modem
control signals, or a physical connector.
TX+
TX-
RX+
RX-
RX+
RX-
TX+
TX-
TX+
TX-
RX+
RX-
RX+
RX-
TX+
TX-
Figure 2-2. RS-485 Two-Wire Connection.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
3. Address Selection
NOTE
Be sure to set the address selections and jumper options before
installation.
The RS422/485 Serial Interface Plus occupies 8 consecutive I/O locations,
and looks to the PC as a standard serial port. DIP switch SW1 sets the port
address options. Be careful when selecting the port address, since some
selections conflict with existing PC ports. The following table shows the
addressing options available with the standard PAL. If you don’t see an
address option that suits your needs, call Black Box about a custom PAL
option.
Port 1
J2
SW1
1
SW1
2
SW1
3
SW1
4
Disabled
3F8
ON
ON
ON
ON
ON
ON
ON
OFF
ON
2F8
ON
ON
OFF
OFF
ON
3E8
ON
ON
OFF
ON
2E8
ON
OFF
OFF
OFF
OFF
ON
3220
3228
4220
4228
238
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
300
ON
OFF
OFF
ON
308
ON
OFF
ON
280
OFF
OFF
OFF
OFF
288
ON
OFF
ON
290
OFF
OFF
298
OFF
Each COM port in your system should have a unique address. Typically
COM1: through COM4: addresses are 3F8, 2F8, 3E8, and 2E8 Hex.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 3: Address Selection
ON
OFF
1
2
3
4
A B C D
Figure 3-1. DIP Switch SW1. Address 3F8 Hex.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
4. Option Selection
NOTE
Be sure to set the address selections and jumper options before
installation.
The RS422/485 Serial Interface Plus contains several jumpers that must be set
for proper operation.
E1: This header selects the interrupt request for the RS422/485 Serial
Interface Plus. If COM1: is selected, this jumper must be on the IRQ4 setting.
If COM2: is selected, this jumper must be on IRQ3. Any two or more ports
can share a common IRQ by placing the jumpers on the same IRQ setting,
and setting the appropriate selections at E3. Consult your particular software
for IRQ selection. If no interrupt is desired, remove the jumper.
NOTE
Most communications-software applications default COM3: to IRQ4 and
COM4: to IRQ3. This requires the sharing of interrupts between COM1:
and COM3:, and between COM2: and COM4:. While this is the default, it
is not always the preferred setting. Windows 3.1, OS/2, and UNIX®
applications typically require a separate IRQ setting for each address.
Check your software configuration instructions to determine the most
appropriate.
2 3 4 5 7 10 11 12 15
Figure 4-1. Header E1 (Factory Default). IRQ 4 Selected.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 4: Option Selection
2 3 4 5 7 10 11 12 15
Figure 4-2. Header E1 Optional Windows 3.1 Configuration. IRQ 10
selected. (Refer to Chapter 6 for more information.)
NOTE
IRQ 2 on AT class machines is not available. IRQ 9 is substituted in place
of IRQ 2. To select IRQ 9, place the jumper on the IRQ 2 position.
E2: “N” indicates the (N)ormal, single-interrupt-per-port mode. The “S”
indicates the (S)hared interrupt mode, which allows more than one port to
access a single IRQ. This is the preferred Windows and OS/2 setting.
Figure 4-3. Header E2 in Normal Mode.
Set jumpers to “N” for single interrupt mode. This setting is the normal
setting for most applications.
Set jumpers to “S” for shared interrupt mode for all ports sharing an IRQ
except for one. Set one of the ports sharing an IRQ to “M.” This provides the
pull-down resistor circuit that makes sharing of IRQs possible.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
M
S
M
S
N
N
Figure 4-4. Header E2 in Shared Mode.
Header E5 is used to control the RS-485 enable/disable functions for the
driver circuit. One of the unique features of the RS422/485 Serial Interface
Plus is its ability to be RS-485 compatible without the need for special software
or drivers. This is especially useful in Windows, Windows NT, and OS/2
environments where the lower level I/O control is abstracted from the
application program. This means that the user can effectively use the
RS422/485 Serial Interface Plus in a RS-485 application with existing software
drivers.
TX
422
RTS
AUTO
Figure 4-5. This jumper is in the “422” position. Note that the modem
control outputs are only valid when Header E5 is in the 422 mode.
AUTO
RTS
422
Driver automatically Enabled/Disabled
Driver Enabled by UART RTS signal
Driver always Enabled
Figure 4-6. Header E5.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 4: Option Selection
Header E3 is used to control the RS-485 enable/disable functions for the
receiver circuit. The RS-485 “Echo” is the result of connecting the board’s
receiver inputs to the transmitter outputs. Every time a character is
transmitted it is also received by the board. This can be beneficial if your
software can handle it (using received characters to throttle the transmitter),
or it can confuse your system if your software cannot handle it. The
RS422/485 Serial Interface Plus provides a jumper block (E3) to enable or
disable this function.
RX
AUTO RTS 422
Figure 4-7. This should follow the selection made at E5 if “No Echo” is
desired. If Echo suppression is not desired, then leave the jumper in
the “422” position. The modem control outputs are only valid when
Header E3 is in the 422 mode.
AUTO
RTS
422
Receiver automatically Enabled/Disabled
Receiver Enabled by UART RTS signal
Receiver always Enabled
Figure 4-8. Header E3.
EIA-530
SIO-485
Figure 4-9. DIP Shunt E4 (EIA-530 Mode).
11
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
DIP shunt E4 selects the pin out for the DB25 connector P3. With the
5-position shunt in the EIA-530 mode, the RS422/485 Serial Interface Plus
complies with the EIA-530 pinout with the following signals supported:
Signal
GND
Name
Ground
Pin #
7
Mode
RDB
RX+
Receive Positive
16
3
Input RS-422
Input RS-422
Input RS-422
Input RS-422
Input RS-422
Input RS-422
Input RS-422
Input RS-422
Output RS-422
Output RS-422
Output RS-422
Output RS-422
Output RS-422
Output RS-422
RDA
RX
Receive Negative
CTSB
CTSA
DSRB
DSRA
DCDB
DCDA
TDB
CTS+
CTS-
DSR+
DSR-
DCD+
DCD-
TX+
Clear To Send Positive
Clear To Send Negative
Data Set Ready Positive
Data Set Ready Negative
Data Carrier Detect Positive
Data Carrier Detect Negative
Transmit Positive
13
5
22
6
10
8
14
2
TDA
TX-
Transmit Negative
RTSB
RTSA
DTRB
DTRA
RTS+
RTS-
DTR+
DTR-
Request To Send Positive
Request To Send Negative
Data Terminal Ready Positive
Data Terminal Ready Negative
19
4
23
20
EIA-530
SIO-485
Figure 4-10. DIP Shunt E4 (SIO-485 Mode).
With the 5-position shunt in the SIO-485 mode, the RS422/485 Serial
Interface Plus converts to 4-wire or 2-wire RS-422/485 with the following
signals supported:
12
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 4: Option Selection
Signal
GND
TDB
TDA
RDB
RDA
Name
Pin #
7
Mode
Ground
TX+
TX-
Transmit Positive
Transmit Negative
Receive Positive
Receive Negative
24
25
12
13
Output RS-422
Output RS-422
Input RS-422
Input RS-422
RX+
RX-
RS-530/422/485 Line Termination
Typically, each end of the RS-530/422/485 bus must have line-terminating
resistors. A 100-ohm resistor is across each RS-530/422/485 input, in addition
to a 1K ohm pull-up/pull-down combination that biases the receiver inputs.
DIP switch SW2 allows you to customize this interface to your specific
requirements. Each switch corresponds to a specific portion of the interface.
If multiple RS422/485 Serial Interface Plus adapters are configured in a
network, only the boards on each end should have switches 1, 2, and 3 ON.
Refer to the following table for each switch’s operation:
Name
T
Function
Adds or removes the 100-ohm termination. Switch 1 ON adds the
termination, and OFF removes the termination.
P
P
Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-485
receiver circuit (Receive data only). Switch 2 ON adds the 1K pull-up
resistor and OFF removes the pull-up resistor.
Adds or removes the 1K ohm pull-down resistor in the RS-422/RS-485
receiver circuit (Receive data only). Switch 3 ON adds the 1K pull-down
resistor, and OFF removes the pull-down resistor.
L
L
Connects the TX+ to RX+ for RS-485 two-wire operation.
Connects the TX- to RX- for RS-485 two-wire operation.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
ON
OFF
1
2
3
4
5
T
P
P
L L
Figure 4-11. DIP Switch SW2.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 5: Installation
5. Installation
IMPORTANT
You MUST set up the operating system BEFORE you physically install
the Card.
5.1 Software Installation
®
If you are installing an ISA adapter in DOS, OS/2 , or QNX, please refer to the
appropriate directory on one of the Serial Utilities Disks for instructions.
5.1.1 WINDOWS 3.1X
Please refer to the /WINDOWS sub-directory on the Serial Utilities Diskette for
help files and current information on the installation of the Card in this operating
environment. Chapter 6 also contains detailed installation instructions.
5.1.2 WINDOWS 95/98
For the ISA card, run setup on disk two of the Serial Utilities Diskettes before
installing the card. Make note of the resources that Windows assigns the adapter,
and set the adapter to match those resources. Power down the computer and
install the adapter as described in Section 5.2. If you wish to change any resources
assigned to the adapter, refer to the help file installed in the Black Box folder in
the Start, Programs menu.
5.1.3 WINDOWS NT
For the ISA card, run setup on disk two of the Serial Utilities Diskettes before
installing the card. After installing the software, refer to the help file that
automatically comes up for installation instructions.
5.2 Hardware Installation
The RS422/485 Serial Interface Plus can be installed in any of the PC
®
™
expansion slots, except J8 on the original IBM PC/XT and Portable. The
Card contains several jumper straps for each port that you must set for proper
operation.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
NOTE
Be sure to set the address selections and jumper options before
installation.
1. Turn off PC power. Disconnect the power cord.
2. Remove the PC case cover.
3. Locate an available slot and remove the blank metal slot cover.
4. Gently insert the Card into the slot. Make sure that the Card is seated
properly.
5. Replace the screw.
6. Replace the cover.
7. Connect the power cord.
Installation is complete.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 6: Windows 3.1 Configuration
6. Windows 3.1 Configuration
To configure the RS422/485 Serial Interface Plus under Windows 3.1, open
the “Control Panel,” which is typically found in the “Main” Program Group.
Next, open the “Ports” selection under the Control Panel.
Control Panel
Settings
Color
Help
Fonts
Ports
Mouse
Desktop Keyboard Fonts
International Data/Time
Network 386 Enhanced Drivers
Sound
Specifies communications settings for serial ports
Select the port you wish to configure. Once you have selected the port, click
on the “Settings” button.
Ports
Cancel
COM 1:
COM 3:
COM 2:
COM 4:
Settings
Help
17
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
The next step is to select the appropriate Baud Rate, Data Bits, Parity, Stop
Bits, and Flow Control.
Settings for COM3:
Baud Rate:
Data Bits:
19200
8
OK
Cancel
Parity:
None
1
Advanced
Help
Stop Bits:
Flow Control:
None
If you wish to select an IRQ or address different from the default, click on the
“Advanced” button.
Advanced Settings for COM 3:
Base I/O Port Address
03E8
OK
Interupt Request Line (IRQ):
10
Cancel
Help
18
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 6: Windows 3.1 Configuration
Select “OK” for all windows after you have made your selection. The following
message should appear:
System Setting Change
Your COM Port settings have changed:
You will need to quit and restart Windows so that the
new setting(s) can take effect.
Don't Restart Now
Restart Now
If you wish to configure another COM Port setting, select the “Don’t Restart
Now” button and repeat this procedure until you have configured all new
ports. To make the changes take effect immediately, select the “Restart Now”
button.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
7. Troubleshooting
Computer does not recognize any COM ports, or the system is “dead”
or non-responsive.
How to identify the problem: Use the SSD.COM Program (found on your
utility diskette).
Solution: Identify all COM ports installed on you computer and address the
RS422/485 Serial Interface Plus at a different address from those already
present.
Reason: Only one device can occupy an address location. If more than one
device tries to share an address space, a conflict will occur, preventing either
device from working.
The RS422/485 Serial Interface Plus’s address is not recognized
by the system.
How to identify the problem: Use the SSD.COM Program (found on your
utility diskette).
Solution: Verify that the RS422/485 Serial Interface Plus addresses are
correctly set.
Reason: If the board is incorrectly addressed, your application will not
respond.
The RS422/485 Serial Interface Plus transmits but does not receive.
The other side appears to receive, but you do not receive any characters
in your application.
How to identify the problem: Verify that the IRQ is set properly on your
RS422/485 Serial Interface Plus and is correctly set in your application
program.
Solution: Change the IRQs so that they are correct.
Reason: Most DOS application programs are “interrupt-driven” on receive. If
the IRQ is not set on the card to match those required by your application, it
will not receive characters, because the interrupt for the first character cannot
be serviced.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 7: Troubleshooting
When using Windows 3.1, only two ports at any time are functional.
How to identify the problem: Verify that all ports have a separate interrupt, or
if sharing interrupts, only one device is using the IRQ at a time.
Solution: Change the IRQs so that each port has its own unique interrupt (the
preferred setting) or close each port before trying to open the next.
Reason: The Windows communication driver does not support simultaneous
operation of shared interrupts.
In Windows 3.1, the mouse hangs or moves erratically.
How to identify the problem: Verify that the mouse is not sharing an interrupt
with any other port or device.
Solution: Change the IRQ of your mouse port so that it does not share an
interrupt. Most mice only operate on either COM1 or COM2 using IRQ 4 and
3 respectively. This is a limitation of the mouse driver.
Reason: A mouse is an interrupt “hog.” Any movement or button-pressing on
the mouse causes an interrupt.
The application requires that the Modem Control signals be “on” or “active,”
but they aren’t connected in my cable.
How to identify the problem: Check the pinout of your cable and the device
you are connected to.
Solution: The unused modem control signals are biased ON on the board.
MSD (Microsoft® Diagnostics) doesn’t report the ports on the RS422/485
Serial Interface Plus.
How to identify the problem: Verify that the RS422/485 Serial Interface Plus
addresses are correctly set.
Solution: Use the program SETCOM (found on your utility diskette) to install
your additional ports.
Reason: MSD only reports the serial ports found by the BIOS. Older BIOS
install only COM1 or COM2. Newer BIOSs will install up to four ports, but
only if the traditional COM port addresses are used.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
The RS422/485 Serial Interface Plus is setup to use the AT interrupts, but
there’s no interrupt response.
How to identify the problem: Verify that the interrupt jumpers are correctly
set. Verify that the card is inserted into a 16-bit or AT slot.
Solution: Use the program SLT (found on your utility diskette) to verify that
the interrupts are set correctly. (Note that SLT requires that the transmit and
receive signals on the connector be “looped back” or connected together.
This can be accomplished by setting SW2 4 and 5 ON.)
Reason: AT IRQs are not found on the 8-bit slots only on 16-bit slots. The
higher level interrupts can never be used in a PC/XT compatible system or if
the board is installed in an 8-bit slot.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 7: Troubleshooting
7.1 Calling Black Box
If you determine that your RS422/485 Serial Interface Plus is malfunctioning,
do not attempt to alter or repair the unit. It contains no user-serviceable
parts. Contact Black Box Technical Support at 724-746-5500.
Before you do, make a record of the history of the problem. We will be able
to provide more efficient and accurate assistance if you have a complete
description, including:
• the nature and duration of the problem.
• when the problem occurs.
• the components involved in the problem.
• any particular application that, when used, appears to create the problem
or make it worse.
7.2 Shipping and Packaging
If you need to transport or ship your RS422/485 Serial Interface Plus:
• Package it carefully. We recommend that you use the original container.
• If you are shipping the Serial Interface Plus for repair, make sure you
include its power supply. If you are returning the Serial Interface Plus,
make sure you include this manual as well. Before you ship, contact Black
Box to get a Return Materials Authorization (RMA) number.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
RS422/485 SERIAL INTERFACE PLUS
Appendix: Circuit-Board Design
25
13
14
1
R 1 4
U 8
U 9
R 1 3
R 1 2
1 R 1
R 1 0
R 9
R 8
R 7
C 8
U 7
C 6
S W 2
S W 1
1
U 6
C 5
R P 1
Y 1
U 5
C 4
1 5
1 2
1 1
1 0
7
5
4
3
2
U 4
U 3
U 2
U 1
C 1
P 2
C 2
C 3
E 1
24
Download from Www.Somanuals.com. All Manuals Search And Download.
© Copyright 2000. Black Box Corporation. All rights reserved.
1000 Park Drive
•
Lawrence, PA 15055-1018
•
724-746-5500
•
Fax 724-746-0746
Download from Www.Somanuals.com. All Manuals Search And Download.
|