Bryant Furnace 313AAV JAV User Manual

313AAV/JAV Plus 80x  
4-WAY MULTIPOISE  
INDUCED--COMBUSTION GAS FURNACE  
INPUT CAPACITIES: 45,000 THRU 135,000 Btuh  
Product Data  
STANDARD FEATURES  
S ECM blower motor included  
S Noise elimination combustion system  
S SmartEvapt can lower the humidity level in the home by  
nearly 10%  
S Four--position furnace: Upflow, Horizontal Right,  
Horizontal Left, Downflow  
Thirteen different vent options  
S Compact design only 33--1/3 in. (847 mm) tall  
S High--Efficiency Media Filtration Cabinet included  
S Washable filter included  
S Microprocessor based “smart” control center  
“Fan on Plust --Continuous Fan speed adjustable from  
thermostat  
Adjustable heating air temperature rise  
Dehumidify mode  
LED diagnostics, non--volatile fault code memory, and self--test  
feature  
A08288  
On--board fuse for transformer protection  
THE BRYANT Plus 80x GAS FURNACE  
The Plus 80x Deluxe 4--Way Multipoise Gas Furnace offers  
outstanding features in an 80% AFUE furnace.  
S Patented blocked vent safeguard to ensure proper furnace  
venting  
Deluxe features include: an ECM motor which enhances SEER  
performance up to 1.5 points*, a third fan relay for discrete  
continuous fan speed, the ability to change continuous fan speeds  
from the thermostat (Fan on Plust), dehumidify mode, standard  
Media Filter Cabinet, fault code storage, and more. The Plus 80x  
is very quiet thanks to a new combustion design that eliminates  
noise, rather than just muffle or box it in. Applications are easy  
with 4--way multipoise design, through--the--furnace downflow  
venting, 13 different venting options, and a door designed for easy  
service access. An inner blower door is provided for tighter sealing  
in sensitive applications. The 313JAV is approved for use in Low  
NOx Air Quality Management Districts.  
S Insulated blower compartment  
S HYBRID HEAT® Dual Fuel System compatible  
S All models are chimney friendly when used with accessory  
vent kit  
S Perfect Lightt Igniter  
S Residential installations eligible for consumer financing  
through the Comfort Credit Program  
*as compared to the Air Conditioning Heating and Refrigeration  
Institute’s standard coil--only ratings when paired with selected  
Bryant evaporator coils.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
BRYANT ACCESSORIES  
A97432  
CONTROLS:  
THERMOSTATS  
AND ZONING  
C04009  
A01484  
Available in programmable and  
non-programmable models,  
Bryant thermostats maintain a  
constant, comfortable tempera-  
ture level in the home.  
MECHANICAL  
MODEL HUMCCLFP  
OR ELECTRONIC  
HUMIDIFIER  
By adding moisture to winter-dry  
air, a Bryanthumidifier can often  
improve comfort and keep  
furniture, rugs, and draperies in  
better condition. Moisturizing  
household air also helps to retain  
normal body heat and provides  
comfort at lower temperatures.  
AIR CLEANER  
Cleans the air of smoke, dirt, and  
many pollens commonly found.  
Saves decorating and cleaning  
expenses by keeping carpets,  
furniture, and drapes cleaner.  
For the ultimate in home comfort,  
Bryant’s 2, 4, and 8-zone systems  
allow temperature control of indi-  
vidual “zones” of the home. This is  
accomplished through a series of  
electronic dampers and  
Electronic air cleaner is shown.  
remote room sensors.  
The  
4-zone system is shown.  
A08153  
ACCESSORIES  
ELECTRONIC AIR CLEANER  
(EAC)  
Model EACB  
AIR PURIFIER  
MECHANICAL AIR CLEANER  
HUMIDIFIER  
Models GAPAAXBB1625, GAPAAXBB2025  
Models EZXCAB, FILCAB  
Model HUM  
HEAT RECOVERY  
VENTILATOR  
ENERGY RECOVERY  
VENTILATOR  
Model HRV  
Model ERV  
UV LIGHTS  
Model UVL  
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N A C , T 2 --- N A C  
F o r u s e w i t h 1 --- s p e e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N H P, T 2 --- N H P *  
F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N R H *  
For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and  
H u m i d i t y C o n t r o l --- T 6 --- P R H {  
T H E R M O S T A T ---  
N O N --- P R O G R A M M A B L E  
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---  
T 6 --- PA C  
F o r u s e w i t h 1 --- s p e e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---  
T6---PHP*  
F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---  
T 6 --- P R H *  
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , 5 --- 2 D a y P r o g r a m m a b l e --- T 6 --- PA C  
T H E R M O S T A T ---  
PROGRAMMABLE  
F o r u s e w i t h m u l t i --- s t a g e a p p l i c a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---  
T 2 --- P H P }  
F o r m u l t i --- u s e / s t a g e c o n f i g u r a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e /  
Temperature and Humidity Control ---T6---PRH{  
Zone Perfect 3---Zone kit --- ZONEBB3ZAC01, ZONEBB3ZHP01  
2 --- Z o n e P e r f e c t P l u s k i t / Te m p e r a t u r e a n d H u m i d i t y C o n t r o l --- Z O N E B B 2 K I T 0 1 --- B  
4 --- Z o n e P e r f e c t P l u s k i t / Te m p e r a t u r e a n d H u m i d i t y C o n t r o l --- Z O N E B B 4 K I T 0 1 --- B  
8 --- Z o n e P e r f e c t P l u s k i t / Te m p e r a t u r e a n d H u m i d i t y C o n t r o l --- Z O N E B B 8 K I T 0 1 --- B  
ZONING CONTROL  
*Model HP and 2S thermostat must be field converted to air conditioner operation.  
{Thermidistatt Control can be configured for multiple use and staging. It must be configured for each specific application.  
}Dual Fuel thermostat is used with furnace and heat pump application.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
BRYANT ACCESSORIES  
DESCRIPTION 313AAV/JAV  
PART NO.  
024045  
X
048070  
X
048090  
X
060110  
X
060135  
FILBBCAR0016  
FILBBCAR0020  
FILBBCAR0024  
EXPXXUNV0016  
EXPXXUNV0020  
EXPXXUNV0024  
EXPXXFIL0016  
EXPXXFIL0020  
EXPXXFIL0024  
KGAFR0401B14  
KGAFR0501B17  
KGAFR0601B21  
KGAFR0701B24  
KGAFR0801SRE  
KGAWF1301UFR {  
KGAWF1401UFR  
KGAWF1501UFR  
KGAWF1306UFR {  
KGAWF1406UFR  
KGAWF1506UFR  
KGAFE0112UPH  
KGASB0201ALL  
KGAVG0101DFG  
KGAVE0101DNH  
KGACA02014FC  
KGACA02015FC  
KGANP4601ALL  
KGAPN3901ALL  
KGALB0101KIT  
KGBAC0110DGK  
KGBAC0110DGK  
KGAHA0150N42  
Cartridge Media Filter  
X
X
X
X
X
X
X
X
X
X
X
X
EZ Flex Media Filter with End Caps  
Replacement EZ Flex Filter Media  
External Bottom Return  
X
X
X
S
X
X
S
Filter Rack  
X
X
External Side Return Filter Rack  
X
S
X
S
S
Unframed Filter 3/4---in. (19 mm)  
X
X
X
X
X
X
X
X
X
Flue Extension  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Combustible Floor Base  
Downflow Vent Guard  
Vent Extension Kit  
Chimney Adapter Kit  
Chimney Adapter Kit  
N a t u r a l --- t o --- P r o p a n e C o n v e r s i o n K i t *  
P r o p a n e --- t o --- N a t u r a l C o n v e r s i o n K i t *  
Label Kit  
Air Leakage Kit (Qty 10)  
Air Leakage Kit (Qty 10)  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KGAHA0250N43  
(factory supplied)  
KGAHA0350N44  
KGAHA0450N45  
KGAHA0550N46  
KGAHA1550N47  
KGAHA1650N48  
KGAHA0650P54  
KGAHA0750P55  
KGAHA0850P56  
KGAHA5750125  
KGAHA5750130  
Gas Orifice Kit (Qty 50)  
See Installation Instructions for model, altitude, and heat value usages.  
*Factory---authorized and field---installed. Gas conversion kits are CSA (AGA/CGA) recognized.  
{Suitable for Side Return Filter Rack (KGAFR0801SRE)  
X
--- Accessor y  
S --- Stan dar d  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
PHYSICAL DATA  
UNIT SIZE  
024045  
048070  
048090  
060110  
060135  
OUTPUT CAPACITY  
BTUH  
( N o n --- w e a t h e r i z e d I C S )  
313JAV Upflow; all 313AAV  
313JAV Downflow/Horizontal  
36,000  
53,000  
72,000  
90,000  
107,000  
34,000  
51,000  
69,000  
86,000  
102,000  
313JAV Upflow; all 313AAV  
313JAV Downflow/Horizontal  
N o n --- w e a t h e r i z e d IC S  
44,000  
42,000  
80.0  
66,000  
63,000  
80.0  
88,000  
84,000  
80.0  
110,000  
105,000  
80.0  
132,000  
126,000  
80.0  
INPUT BTUH  
AFUE%  
SHIPPING WEIGHT LB. (KG)  
104 (47)  
126 (57)  
140 (64)  
152 (69)  
163 (74)  
30---60  
( 1 7 --- 3 3 )  
25---55  
( 1 4 --- 3 1 )  
35---65  
( 1 9 --- 3 6 )  
30---60  
( 1 7 --- 3 3 )  
40---70  
( 2 2 --- 3 9 )  
CERTIFIED TEMP RISE RANGE ˚_F (_C)  
Heating  
Cooling  
Heating  
Cooling  
0.10  
0.50  
735  
0.12  
0.50  
1230  
1460  
0.15  
0.50  
1345  
1665  
SPST  
0.20  
0.50  
1890  
2040  
0.20  
0.50  
1865  
2070  
CERTIFIED EXT STATIC  
PRESSURE (IN. WC)  
AIRFLOW CFM  
1035  
LIMIT CONTROL  
HEATING BLOWER CONTROL  
BURNERS (Monoport)  
Solid---State Time Operation  
4
2
3
5
6
GAS CONNECTION SIZE  
1 / 2 --- in . N P T  
GAS VALVE(Redundant) Manufacturer  
Minimum Inlet Pressure (in. wc)  
Maximum Inlet Pressure (in. wc)  
IGNITION DEVICE  
W h it e --- R o d g e r s  
4.5 (Natural Gas)  
13.6 (Natural Gas)  
Hot Surface  
*Gas input ratings are certified for elevations to 2000 ft. (610 M)*. In USA, For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305  
M) above sea level. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 --- 1372 M) above sea level. Refer to National Fuel Gas Code  
NFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions.  
{Capacity in accordance with U.S. Government DOE test procedures.  
}Airflow shown is for bottom only return---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each  
return---air supply. An airflow reduction of up to 7 percent may occur when using a Bryant 4---5/16 in. (110 mm) high efficiency media filter.  
ICS --- Isolated Combustion System  
BLOWER PERFORMANCE DATA  
UNIT SIZE  
024045  
1/2  
6.8  
048070  
3/4  
8.4  
048090  
3/4  
8.4  
060110  
1
10.9  
060135  
1
10.9  
DIRECT---DRIVE MOTOR Hp (ECM --- 5 Speed)  
MOTOR FULL LOAD AMPS  
R P M ( N o m i n a l ) --- S P E E D S  
1050---5  
1050---5  
1050---5  
1050---5  
1050---5  
10 x 6  
(254 x 152)  
11 x 8  
(279 x 203)  
10X10  
(254 x 254)  
11 x 11  
(279 x 279)  
11 x 11  
(279 x 279)  
BLOWER WHEEL DIAMETER x WIDTHS --- IN (MM)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEE NOTES: 1,2,3,4,7,8,9  
SEE NOTES: 1,2,4,5,7,8,9  
SEE NOTES: 1,2,4,7,8,9  
UPFLOW  
DOWNFLOW  
UPFLOW  
A02061  
A02058  
A02059  
SEE NOTES:1,2,3,4,5,7,8,9  
DOWNFLOW  
SEE NOTES: 1,2,3,4,7,8,9  
DOWNFLOW  
SEE NOTES: 1,2,4,5,6,7,8,9  
DOWNFLOW  
A02062  
A02060  
A02063  
Venting Notes  
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC),  
NFPA54/ANSI Z223.1. In Canada, latest edition of the National Standards of Canada, Natural Gas and Propane Installation Code  
(NSCNGPIC), CSA B149.1.  
2. Immediately increase to 5--in. (127 mm) vent connector outside furnace casing when 5--in. (127 mm) vent connector required, refer to  
Note 1.  
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when  
KGAVG0101DFG is used in downflow position.  
4. Type B vent where required, refer to Note 1.  
5. 4--in. (102 mm) single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit.  
6. Accessory Downflow Vent Guard Kit, KGAVG0101DFG required in downflow installations with bottom vent configuration.  
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and  
KGACA02015FC for sizing and complete application details.  
8. Secure vent connector to furnace elbow with (2) corrosion--resistant sheet metal screws, space approximately 180_ apart.  
9. Secure all other single wall vent connector joints with (3) corrosion--resistant screws spaced approximately 120_ apart. Secure Type B  
vent connectors per vent connector manufacturer’s recommendations.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL RIGHT  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL RIGHT  
A02068  
A02070  
SEE NOTES: 1,2,4,7,8,9  
HORIZONTAL RIGHT  
A02069  
SEE NOTES: 1,2,4,7,8,9  
HORIZONTAL LEFT  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL LEFT  
A02064  
A02065  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL LEFT  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL LEFT  
A02067  
A02066  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIR DELIVERY -- CFM (WITH FILTER)*  
EXTERNAL STATIC PRESSURE (in. wc)  
RETURN---AIR  
UNIT SIZE  
SPEED  
SUPPLY  
0.1  
1185  
920  
735  
820  
0.2  
1145  
880  
685  
765  
0.3  
1115  
835  
625  
725  
0.4  
1075  
800  
0.5  
1035  
755  
0.6  
980  
720  
0.7  
905  
680  
0.8  
820  
0.9  
720  
1
580  
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
645  
605  
540  
Bottom or  
Side(s)  
024045  
585  
530  
490  
435  
395  
345  
295  
670  
630  
580  
545  
490  
455  
405  
650  
595  
535  
490  
430  
390  
330  
280  
235  
--- ---  
1625  
1405  
1240  
1190  
1035  
1845  
1590  
1365  
1225  
1100  
2255  
1600  
1945  
1420  
1280  
2295  
1725  
1910  
1630  
1430  
1585  
1360  
1200  
1140  
985  
1535  
1320  
1155  
1095  
930  
1755  
1500  
1270  
1110  
960  
2150  
1465  
1830  
1280  
1140  
2185  
1605  
1800  
1510  
1285  
1495  
1280  
1110  
1050  
885  
1460  
1240  
1065  
1000  
835  
1415  
1195  
1020  
955  
1365  
1155  
975  
915  
745  
1295  
1115  
935  
1220  
1070  
895  
1125  
1030  
850  
Bottom or  
Side(s)  
048070  
048090  
060110  
060135  
870  
830  
790  
785  
695  
650  
600  
1800  
1545  
1320  
1160  
1030  
2205  
1525  
1890  
1340  
1205  
2240  
1660  
1865  
1575  
1355  
1710  
1455  
1215  
1060  
875  
1665  
1410  
1170  
1010  
805  
1595  
1365  
1125  
950  
1500  
1315  
1070  
895  
1400  
1270  
1025  
830  
1275  
1180  
955  
1105  
1000  
900  
Bottom or  
Side(s)  
770  
710  
730  
645  
570  
505  
425  
2100  
1400  
1770  
1200  
1055  
2125  
1545  
1745  
1435  
1200  
2040  
1335  
1715  
1140  
990  
2070  
1460  
1685  
1365  
1125  
1985  
1275  
1655  
1065  
910  
2005  
1395  
1610  
1300  
1075  
1920  
1210  
1600  
1005  
840  
1925  
1340  
1545  
1245  
1015  
1835  
1150  
1545  
925  
1735  
1080  
1480  
865  
1615  
1015  
1430  
790  
Bottom or  
Side(s)  
760  
695  
630  
1805  
1285  
1485  
1185  
945  
1670  
1230  
1435  
1130  
855  
1545  
1170  
1380  
1065  
800  
Bottom or  
Side(s)  
*A filter is required for each return---air inlet. Airflow performance included 3/4---in. (19 mm) washable filter media such as contained in factory ---authorized ac-  
cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure.  
--- --- Indicates unstable operating conditions.  
ELECTRICAL DATA  
OPERATING VOLTAGE  
313AAV/  
JAV UNIT  
SIZE  
V O LT S ---  
H E R T Z ---  
PHASE  
MAXIMUM FUSE  
OR CKT BKR  
AMPS{  
MAXIMUM  
MAXIMUM WIRE  
MINIMUM  
WIRE GAGE  
RANGE*  
UNIT AMPS  
LENGTH FT (M)}  
Maximum  
127  
Minimum  
104  
024045  
048070  
048090  
060110  
060135  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
8.1  
9.5  
10.3  
13.1  
13.1  
34 (10)  
29 (9)  
27 (8)  
34 (10)  
34 (10)  
15  
15  
15  
20  
20  
14  
14  
14  
12  
12  
127  
104  
127  
104  
127  
104  
127  
104  
* Permissible limits of the voltage range at which the unit operates satisfactorily.  
{ Time---delay type is recommended.  
}Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIMENSIONS  
(733mm)  
28-7/8"  
(664mm)  
26-1/8"  
(FLUE COLLAR)  
(641mm)  
25-1/4"  
2-7/16"  
(62mm)  
1-5/16"  
(33mm)  
22-9/16"  
(573mm)  
A
D
AIRFLOW  
13/16"  
(21mm)  
19"  
(483mm)  
JUNCTION BOX  
LOCATION  
13/16"  
(21mm)  
1-1/8"  
(29mm)  
5-15/16"  
(135mm)  
OUTLET  
4-13/16"  
(122mm)  
F
1/2" DIA. K.O.THERMOSTAT  
(22mm)  
7/8" DIA  
ACCESSORY  
9-5/8"  
(244mm)  
WIRE ENTRY  
(13mm)  
11/16" 7-3/4"  
(17mm)(197mm)  
8-9/16"  
(217mm)  
1-3/4" DIA.RIGHT HAND  
GAS ENTRY (44mm)  
1/2" (13 mm) DIA.  
THERMOSTAT WIRE ENTRY  
11-1/2"  
(292mm)  
3-15/16" (84mm)  
LEFT HAND GAS  
ENTRY  
7/8" DIA. K.O. WIRE ENTRY  
(22mm)  
ALTERNATE  
33-5/16"  
(846mm)  
JUNCTION BOX  
24-7/8"  
(632mm)  
LOCATIONS (TYP)  
VENT OUTLET  
5 PLACES (TYP)  
14-7/8"  
(378mm)  
7/8" (22mm) DIA.  
ACCESSORY  
7/8" DIA. ACCESSORY  
(22mm)  
5-1/2" (140mm)  
5-1/2"  
(140mm)  
11/16"  
(17mm)  
(549mm)  
1-1/2"  
(38mm)  
11/16"  
(17mm)  
1-1/4"  
3-3/4"  
(95mm)  
E
21-5/8"  
1-11/16"  
(43mm)  
(32mm)  
(560mm)  
22-1/16"  
SIDE INLET  
BOTTOM INLET  
1"  
(25mm)  
24"  
CASING  
(610mm)  
A04037  
1. Two additional 7/8--in. (22 mm) dia. knockouts are located in the top plate.  
2. Minimum return--air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.  
3. Minimum return--air opening at furnace.  
a. For 800 CFM--16--in. (406 mm) round or 14--1/2 x 12--in. (368 x 305 mm) rectangle.  
b. For 1200 CFM--20--in. (508 mm) round or 14--1/2 x 19--1/3 in. (368 x 491 mm)rectangle.  
c. For 1600 CFM--22--in. (559 mm) round or 14--1/2 x 22--1/16--in. (368 x 560 mm) rectangle.  
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a  
combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only  
will ensure adequate return air openings for airflow requirements above 1800 CFM.  
A
E
F
VENT  
CONNECTION  
SIZE  
D
MEDIA CABINET  
SIZE  
313AAV/JAV  
UNIT SIZE  
CABINET  
WIDTH  
IN (MM)  
BOTTOM  
TOP VENT  
OUTLET  
IN (MM)  
SUPPLY WIDTH  
IN (MM)  
RETURN WIDTH  
IN (MM)  
IN (MM)  
(see Notes 1 & 2)  
024045  
048070  
048090  
060110  
060135  
14---3/16 (360)  
17---1/2 (445)  
21 (533)  
21 (533)  
24---1/2 (622)  
12---9/16 (319)  
15---7/8 (403)  
19---3/8 (492)  
19---3/8 (492)  
22---7/8 (581)  
12---11/16 (322)  
16---1/8 (410)  
19---1/2 (495)  
19---1/2 (495)  
23 (584)  
9---5/16 (237)  
11---9/16 (294)  
13---5/16 (338)  
13---5/16 (338)  
15---1/16 (383)  
4
4
4
4
16 (406)  
16 (406)  
20 (508)  
20 (508)  
24 (610)  
4 (Note 1)  
1. 135 size furnaces require 5---in. (127 mm) vents. Use a 4---5 in. (102---127 mm) vent adaptor between furnace and vent stack.  
2. See installation instructions for complete installation requirements.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
A08471  
ISO 9001:2000  
D
MEETS DOE RESIDENTIAL CONSERVATION  
EFFICIENCY  
RATING  
SERVICES PROGRAM STANDARDS.  
CERTIFIED  
Before purchasing this appliance, read important  
energy cost and efficiency information available  
from your retailer.  
REGISTERED  
CERTIFIED  
®
5
/
25 8" (651mm)  
5
/
8
23  
"
1
(600mm)  
(651mm)  
/
24  
2
"
With Flanges Bent Out  
3
/
8
1
23  
"
(587mm)  
/
23  
8
"
(600mm)  
Opening  
A
B
Furnace Side  
Duct Side  
3
/
4"  
23  
Centerline Screw Slots  
3
/
4
5
"
(603mm)  
Media/  
(146mm)  
Filter Cabinet  
A
B
C
1
/
15"/  
(41327m"/m) 16 4"/  
(406mm)  
16"/  
20"/(508mm)  
(610mm)  
(413mm)  
(31819m"/m)  
1
/
(52331m"/m)  
(62355m"/m)  
20 4"/  
(514mm)  
(483mm)  
1
/
23"/  
24 4"/  
24"/  
(616mm)  
(584mm)  
A00444  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL WIRING SCHEMATIC  
FIELD 24-V WIRING  
FIELD 115-, 208/230-, 460-V WIRING  
FACTORY 24-V WIRING  
FACTORY 115-V WIRING  
NOTE 2  
THERMOSTAT  
TERMINALS  
W
C
R
G
Y
FIVE WIRE  
FIELD-SUPPLIED  
DISCONNECT  
THREE-WIRE  
HEATING-ONLY  
208/230- OR  
460-V  
BLOWER DOOR SWITCH  
THREE  
PHASE  
W
R
BLK  
BLK  
C
O
N
T
R
O
L
WHT  
WHT  
208/230-V  
SINGLE  
PHASE  
GND  
GND  
G
AUXILIARY  
J-BOX  
115-V FIELD-  
SUPPLIED  
DISCONNECT  
COM  
Y/Y2  
GND  
NOTE 1  
CONDENSING  
UNIT  
TWO  
WIRE  
24-V  
TERMINAL  
BLOCK  
NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation.  
2. Some thermostats require a "C" terminal connection as shown.  
3. If any of the original wire, as supplied, must be replaced, use  
same type or equivalent wire.  
FURNACE  
A99440  
TYPICAL INSTALLATION  
CONDENSING  
UNIT  
HUMIDIFIER  
GAS-FIRED  
WATER HEATER  
ELECTRONIC  
AIR CLEANER  
AIRFLOW  
A08177  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Casing  
GUIDE SPECIFICATIONS  
Casing shall be of .030 in. (.76 mm) thickness minimum,  
pre--painted galvanized steel.  
Gas Furnace  
313AAV/JAV  
Inducer Motor  
Inducer motor shall be soft mounted to reduce vibration  
transmission.  
GENERAL  
System Description  
Furnish a _________________ fixed capacity gas--fired furnace  
for use with natural gas or propane (factory authorized conversion  
kit required for propane); furnish cold air return plenum; furnish  
external medial cabinet for use with accessory media filter or  
standard filter.  
Draft Safeguard Switch  
Draft Safeguard Switch (blocked vent safeguard) shall be factory  
installed to reduce the possibility of vent gas infiltration due to a  
blocked or restricted vent pipe.  
Heat Exchangers  
Quality Assurance  
Unit will be designed, tested and constructed to the current ANSI Z  
21.47/CSA 2.3 design standard for gas--fired central furnaces.  
Heat exchangers shall be a 4--Pass 20 gage aluminized steel of  
fold--and--crimp sectional design when applied operating under  
negative pressure.  
Unit will be 3rd party certified by CSA to the current ANSI Z  
21.47/CSA 2.3 design standard for gas--fired central furnaces.  
Controls  
Control shall include a micro--processor based integrated electronic  
control board with at least 11 service troubleshooting codes  
displayed via diagnostic flashing LED light on the control, a  
self--test feature that checks all major functions of the furnace  
within one minute, and a replaceable automotive--type circuit  
protection fuse. Multiple operational settings available including,  
separate blower speeds for heating, cooling and continuous fan.  
Continuous fan speed may be adjusted from the thermostat.  
Features will also include temporary reduced airflow in the cooling  
mode for improved dehumidification when a Thermidistatt  
Control is selected as the thermostat.  
Unit will carry the CSA Blue Star® and Blue Flame® labels.  
Unit efficiency testing will be performed per the current DOE test  
procedure as listed in the Federal Register.  
Unit will be certified for capacity and efficiency and listed in the  
latest GAMA Consumer’s Directory of Certified Efficiency  
Ratings.  
Unit will carry the current Federal Trade Commission Energy  
Guide efficiency label.  
Delivery, Storage and Handling  
Unit shall be shipped as single package only and is stored and  
handled per unit manufacturer’s recommendations.  
Operating Characteristics  
Heating Capacity shall be ________ Btuh input; ________ Btuh  
output capacity.  
Warranty (for inclusion by specifying engineer)  
U.S. and Canada only. Warranty certificate available upon request.  
Fuel Gas Efficiency shall be 80% AFUE.  
Air delivery shall be ___________ CFM minimum at 0.50 in. wc  
external static pressure.  
PRODUCTS  
Equipment  
Dimensions shall be: depth __________ in.; width _________ in;  
height_________in. (mm) (casing only). Height shall  
be_________in. (mm) with A/C coil and _____________in. (mm)  
overall with plenum.  
Components shall include: slow--opening gas valve to reduce  
ignition noise, regulate gas flow, with electric switch gas shut--off;  
flame proving sensor, hot surface igniter, pressure switch assembly;  
flame rollout switch, blower and inducer assembly, 40va  
transformer; low--voltage (heating) (heating/ cooling) thermostat.  
Electrical Requirements  
Blower Wheel and Blower Motor  
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).  
Minimum wire size shall be_________AWG; maximum fuse size  
or circuit breaker shall be __________Amps.  
Galvanized blower wheel shall be centrifugal type, statically and  
dynamically balanced. Blower motor of ECM type shall be  
permanently lubricated with sealed bearings, of _______hp, and  
shall be multiple--speed direct drive. Blower motor shall be soft  
mounted to the blower scroll to reduce vibration transmission.  
Special Features  
Refer to section of the product data sheet identifying accessories  
and descriptions for specific features and available enhancements.  
Filters  
Furnace may have reusable--type filters. Filter shall be _______ in  
(x) _______in. (mm).An accessory high efficiency Media Filter is  
available as an option. _______________ Media Filter.  
8 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231  
Printed in U.S.A.  
Edition Date: 3/09  
Catalog No. PDS313AAV--- 0 4  
Replaces: PDS313AAV---03  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

BenQ Projector MP721 721c User Manual
Bionaire Humidifier BU5000 User Manual
BodyCraft Flat Panel Television 410LP User Manual
Bowers Wilkins Speaker DM601 User Manual
Breville Juicer BJE510XL A User Manual
Briggs Stratton Lawn Mower 1695354 User Manual
Cambridge Audio Stereo Receiver 840A V2 User Manual
Carrier Access Network Router 002 0118 0180 User Manual
Chamberlain Intercom System NDIS User Manual
Chicago Electric Welder 92496 User Manual