AutoDome Power Supply
Boxes
VG4-A-PSU0 | VG4-A-PSU1 | VG4-A-PSU2
en Installation Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Table of Contents | en
3
Table of Contents
1
Important Safety Instructions
5
5
1.1
1.2
1.3
1.4
1.5
Safety precautions
Important safety instructions
Important Notices
UL certification
6
8
10
10
Bosch notices
2
Installing the Power Supply Box
Unpacking
12
12
12
12
13
13
13
15
16
18
18
21
22
2.1
2.1.1
2.1.2
2.1.3
2.1.4
2.2
Parts List
Optional Parts List
Description
Tools Required
Pre-installation Check List
Mount the Power Supply Box
Attach Cover Door
2.3
2.3.1
2.4
Route Wires and Attach Connectors
Methods for Routing Wires
Wiring the Power Supply Box
Power Supply Box Connections
2.4.1
2.4.2
2.4.3
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
4
en | Table of Contents
AutoDome Power Supply Boxes
3
Cable and Wire Standards
24
24
24
25
3.1
Power
3.2
Wire Distance Guide
Video and Control Cables
3.3
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
Using Coaxial Cable to Transmit Video and Control
Using UTP to Transmit Video and Control
25
26
27
Using Ethernet to Transmit Video and Control
Using Multi-mode Fiber Optic to Transmit Video and Control 27
Using a Fiber Optic Ethernet Media Converter to Transmit Video
and Control
28
29
29
30
32
34
3.4
Control-only Cables
3.4.1
3.4.2
3.4.3
3.5
Controlling the AutoDome via Biphase
Controlling the AutoDome via the RS232 Protocol
Controlling the AutoDome via the RS485 Protocol
Fiber Optic Module with an RS232/RS422 Controller
3.5.1
3.5.2
3.6
Connecting to an LTC 4629 Head End Data/Video Transceiver 34
Configuring the VG5 AutoDome
Audio Cables
34
36
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Important Safety Instructions | en
5
1
Important Safety Instructions
Read, follow, and retain all of the following safety instructions.
Heed all warnings on the unit and in the operating instructions
before operation.
1.1
Safety precautions
DANGER!
High risk: This symbol indicates an imminently hazardous
situation such as “Dangerous Voltage” inside the product.
If not avoided, this will result in an electrical shock, serious
bodily injury, or death.
WARNING!
Medium risk: Indicates a potentially hazardous situation.
If not avoided, this could result in minor or moderate bodily
injury.
CAUTION!
Low risk: Indicates a potentially hazardous situation.
If not avoided, this could result in property damage or risk of
damage to the unit.
NOTICE!
This symbol indicates information or a company policy that
relates directly or indirectly to the safety of personnel or
protection of property.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
6
en | Important Safety Instructions
AutoDome Power Supply Boxes
1.2
Important safety instructions
Read, follow, and retain for future reference all of the following
safety instructions. Heed all warnings on the unit and in the
operating instructions before operating the unit.
1. Cleaning - Unplug the unit from the outlet before cleaning.
Follow any instructions provided with the unit. Generally,
using a dry cloth for cleaning is sufficient but a moist, fluff-
free cloth or leather shammy may also be used. Do not use
liquid cleaners or aerosol cleaners.
2. Water - Do not use this unit near water, for example near a
bathtub, washbowl, sink, laundry basket, in a damp or wet
basement, near a swimming pool, in an outdoor
installation, or in any area classified as a wet location. To
reduce the risk of fire or electrical shock, do not expose
this unit to rain or moisture.
3. Object and liquid entry - Never push objects of any kind
into this unit through openings as they may touch
dangerous voltage points or short-out parts that could
result in a fire or electrical shock. Never spill liquid of any
kind on the unit. Do not place objects filled with liquids,
such as vases or cups, on the unit.
4. Power cord and plug protection - Protect the plug and
power cord from foot traffic, being pinched by items
placed upon or against them at electrical outlets, and its
exit from the unit. For units intended to operate with
230 VAC, 50 Hz, the input and output power cord must
comply with the latest versions of IEC Publication 227 or
IEC Publication 245.
5. Power disconnect - Units have power supplied to the unit
whenever the power cord is inserted into the power
source. The power cord plug is the main power disconnect
device for switching off the voltage for all units.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Important Safety Instructions | en
7
6. Power sources - Operate the unit only from the type of
power source indicated on the label. Before proceeding,
be sure to disconnect the power from the cable to be
installed into the unit.
–
–
–
For battery powered units, refer to the operating
instructions.
For external power supplied units, use only the
recommended or approved power supplies.
For limited power source units, this power source
must comply with EN60950. Substitutions may
damage the unit or cause fire or shock.
For 24 VAC units, voltage applied to the unit's power
input should not exceed 10%, or 28 VAC. User-
supplied wiring must comply with local electrical
codes (Class 2 power levels). Do not ground the
supply at the terminals or at the unit's power supply
terminals.
–
–
If unsure of the type of power supply to use, contact
your dealer or local power company.
7. Servicing - Do not attempt to service this unit yourself.
Opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified
service personnel.
8. Damage requiring service - Unplug the unit from the main
AC power source and refer servicing to qualified service
personnel when any damage to the equipment has
occurred, such as:
–
–
the power supply cord or plug is damaged;
exposure to moisture, water, and/or inclement
weather (rain, snow, etc.);
–
–
–
–
–
liquid has been spilled in or on the equipment;
an object has fallen into the unit;
unit has been dropped or the unit cabinet is damaged;
unit exhibits a distinct change in performance;
unit does not operate normally when the user
correctly follows the operating instructions.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
8
en | Important Safety Instructions
AutoDome Power Supply Boxes
9. Replacement parts - Be sure the service technician uses
replacement parts specified by the manufacturer, or that
have the same characteristics as the original parts.
Unauthorized substitutions may cause fire, electrical
shock, or other hazards.
10. Safety check - Safety checks should be performed upon
completion of service or repairs to the unit to ensure
proper operating condition.
11. Installation - Install in accordance with the manufacturer's
instructions and in accordance with applicable local codes.
12. Attachments, changes or modifications - Only use
attachments/accessories specified by the manufacturer.
Any change or modification of the equipment, not
expressly approved by Bosch, could void the warranty or,
in the case of an authorization agreement, authority to
operate the equipment.
1.3
Important Notices
U.S.A. models only - Section 810 of the National Electrical Code,
ANSI/NFPA No.70, provides information regarding proper
grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors,
location of discharge unit, connection to grounding electrodes,
and requirements for the grounding electrode.
Disposal - Your Bosch product was developed and
manufactured with high-quality material and components that
can be recycled and reused. This symbol means that electronic
and electrical appliances, which have reached the end of their
working life, must be collected and disposed of separately
from household waste material. Separate collecting systems
are usually in place for disused electronic and electrical
products. Please dispose of these units at an environmentally
compatible recycling facility, per European Directive 2002/96/
EC
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Important Safety Instructions | en
9
Environmental statement - Bosch has a strong commitment
towards the environment. This unit has been designed to
respect the environment as much as possible.
Power lines: An outdoor system should not be located in the
vicinity of overhead power lines, electrical lights, or power
circuits, or where it may contact such power lines or circuits.
When installing an outdoor system, extreme care should be
taken to keep from touching power lines or circuits, as this
contact may be fatal.
U.S.A. models only - refer to the National Electrical Code Article
820 regarding installation of CATV systems.
SELV - All the input/output ports are Safety Extra Low Voltage
(SELV) circuits. SELV circuits should only be connected to
other SELV circuits.
Because the ISDN circuits are treated like telephone-network
voltage, avoid connecting the SELV circuit to the Telephone
Network Voltage (TNV) circuits.
System ground/Safety ground
System (video) ground is indicated by the symbol
.
.
Safety (power) ground is indicated by the symbol
The system ground is only used to comply with safety standards
or installation practices in certain countries. Bosch does not
recommend connecting system ground to safety ground unless
it is explicitly required. However, if the system ground and
safety ground are connected and grounding loops are causing
interference in the video signal, use an isolation transformer
(available separately from Bosch).
CAUTION!
Connecting System ground to Safety ground may result in
ground loops that can disrupt the CCTV system.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
10 en | Important Safety Instructions
AutoDome Power Supply Boxes
1.4
UL certification
Disclaimer
Underwriter Laboratories Inc. (“UL”) has not tested the
performance or reliability of the security or signaling aspects of
this product. UL has only tested fire, shock and/or casualty
hazards as outlined in UL's Standard(s) for Safety for Closed
Circuit Television Equipment, UL 2044. UL Certification does not
cover the performance or reliability of the security or signaling
aspects of this product.
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR
CERTIFICATIONS WHATSOEVER REGARDING THE
PERFORMANCE OR RELIABILITY OF ANY SECURITY OR
SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.
Disclaimer
Underwriter Laboratories Inc. (“UL”) has not tested the
performance or reliability of the security or signaling aspects of
this product. UL has only tested fire, shock and/or casualty
hazards as outlined in UL's Standard(s) for Safety for Information
Technology Equipment, UL 60950-1. UL Certification does not
cover the performance or reliability of the security or signaling
aspects of this product.
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR
CERTIFICATIONS WHATSOEVER REGARDING THE
PERFORMANCE OR RELIABILITY OF ANY SECURITY OR
SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT.
1.5
Bosch notices
Video loss
Video loss is inherent to digital video recording; therefore,
Bosch Security Systems cannot be held liable for any damage
that results from missing video information. To minimize the
risk of lost digital information, Bosch Security Systems
recommends multiple, redundant recording systems, and a
procedure to back up all analog and digital information.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Important Safety Instructions | en 11
Copyright
This manual is the intellectual property of Bosch Security
Systems and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this
document are likely to be registered trademarks and must be
treated accordingly.
Note:
This manual has been compiled with great care and the
information it contains has been thoroughly verified. The text
was complete and correct at the time of printing. The ongoing
development of the products may mean that the content of the
user guide can change without notice. Bosch Security Systems
accepts no liability for damage resulting directly or indirectly
from faults, incompleteness or discrepancies between the user
guide and the product described.
More information
For more information please contact the nearest Bosch Security
Systems location or visit www.boschsecurity.com
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
12 en | Installing the Power Supply Box
AutoDome Power Supply Boxes
2
Installing the Power Supply Box
2.1
Unpacking
This equipment should be unpacked and handled with care. If
an item appears to have been damaged in shipment, notify the
shipper immediately.
Verify that all the parts listed in the product's Parts List below
are included. If any items are missing, notify your Bosch
Security Systems Sales or Customer Service Representative.
The original packing carton is the safest container in which to
transport the unit and must be used if returning the unit for
service. Save it for possible future use.
2.1.1
Parts List
The following table lists the parts included with one of the
following power supply boxes:
Power Supply Box
Part Number
24 VAC (no transformer) power supply,
NEMA-rated with cover
VG4-A-PSU0
120 VAC transformer power supply,
NEMA-rated with cover
VG4-A-PSU1
VG4-A-PSU2
230 VAC transformer power supply,
NEMA-rated with cover
2.1.2
Optional Parts List
The following table lists the optional equipment for use with
the power supply boxes:
Option
Part Number
Trim skirt
VGA-A-TSKIRT
VG4-SBOX-COVER
VGA-FIBER-AN
VG4-SFPSCKT
Replacement power supply box cover
Analog Multimode Fiber Optic Kit
Ethernet Media Converter Kit
Note: The fiber optic kits are mounted inside the power supply
box. Refer to the individual kit for installation instructions.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Installing the Power Supply Box | en 13
2.1.3
Description
This chapter details how to install an AutoDome power supply
box. Any variations to the installation procedures are noted.
These power supply boxes are intended for use with the
VGA-PEND_ARM Arm Mount, VGA-A-9543 Pipe Mount, and the
VG4-A-9230 or VGA-ROOF-MOUNT Roof Parapet Mount.
For complete AutoDome installation, mounting, and wiring
information, refer to the VG5 Series AutoDome Installation
Manual that was included with the AutoDome pendant
packaging.
2.1.4
Tools Required
–
Small straight blade screwdrivers ~ 2.5 mm (0.1 in.) – 3.1
mm (1/8 in.)
–
–
–
–
–
Medium straight blade screwdriver
No. 1 and No. 2 Phillips screwdrivers
Socket wrench and 9/16 in. socket
Power drill
Water tight conduits and fittings that meet NEMA 4
standards
2.2
Pre-installation Check List
1. Determine the location and distance for the power supply
box based on its voltage and current consumption. Refer
to Section 3 Cable and Wire Standards, page 24 for wiring
information and distances.
2. Use only UL listed liquid-tight strain reliefs for conduits to
the power supply box to ensure that water cannot enter
the box. You must use water tight conduits and fittings to
meet NEMA 4 standards.
NOTICE!
Power and I/O cabling must be routed separately inside
different permanently earthed metal conduits.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
14 en | Installing the Power Supply Box
AutoDome Power Supply Boxes
3. Install all rough wiring including: power, control, video
coax, alarms I/O, relay I/O, and fiber optic cabling. Refer to
Section 3 Cable and Wire Standards, page 24 for video and
control protocol methods.
4. Analog AutoDome: If you plan to use the RS232 or RS485
protocol to control the AutoDome, refer to
Section 3.4.2 Controlling the AutoDome via the RS232
Protocol, page 30, or Section 3.4.3 Controlling the
AutoDome via the RS485 Protocol, page 32, for instructions
on configuring the AutoDome to accept these protocols.
WARNING!
External interconnecting cables are to be installed in
accordance to NEC, ANSI/NFPA70 (for US application) and
Canadian Electrical Code, Part I, CSA C22.1 (for CAN
application) and in accordance to local country codes for all
other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed
Circuit Breaker or Branch Rated Fuses are required as part of
the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be
incorporated.
5. Purchase the appropriate mounting hardware to use,
depending on the location of power supply box.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Installing the Power Supply Box | en 15
2.3
Mount the Power Supply Box
Before mounting the power supply box decide if you will be
wiring the box through the holes in the bottom or back of the
box. If wiring the box through the back, move the two (2) seal
plugs to the bottom holes before mounting.
NOTICE!
Use 3/4-inch NPS (20-mm) fittings for the holes on the bottom
and back of the box. Use 1/2-inch NPS (15-mm) fittings for the
side holes.
Figure 2.1 Power Supply Box with Optional Trim Skirt
1. Use the wall mount template supplied in the packaging box
to locate the four (4) mounting holes for the power supply
box.
2. Drill four (4) holes for the mounting anchors. If installing
outdoors, apply a weatherproof sealant around each hole
at the mounting surface.
3. Place the power supply box into the optional trim skirt.
4. Secure the power supply box to the wall using four (4)
corrosion-resistant stainless steel studs (not included).
NOTICE!
A stud diameter of 6.4 mm (1/4 in.) or 8 mm (5/16 in.), able to
withstand a 120 kg (265 lb) pull-out force is recommended.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
16 en | Installing the Power Supply Box
AutoDome Power Supply Boxes
5. Attach the 3/4 in. (20 mm) watertight pipe fittings (not
supplied) to the holes of the power supply box through
which you will run the power, video, and control data
wires.
2.3.1
Attach Cover Door
1. Compress the bottom hinge pin by pushing the pin lever
down and then rotate it behind the hinge pin stop. The
power box cover door provides a hinge pin stop to hold the
bottom hinge open while attaching the door.
90o
24V NC 24V
GND TXD RXD ꢀꢀꢀ C+ C-
GND TXD RXD ꢀꢀꢀ C+ C-
Figure 2.2 Align Cover Door Hinge to Power Box
1
2
3
4
Power Supply Box
Cover Door
Align Top Hinge
Align Bottom Hinge
5
6
7
Hold Hinge Pin Open
Open Position
Hinge Pin Stop
2. Open the top hinge by pushing its pin lever outward and
holding it open.
Note: Both hinge pins must be fully compressed to open
(unlock) the female hinges of the cover door before
proceeding to the next step.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Installing the Power Supply Box | en 17
3. While holding the top hinge pin open, position the cover
door to the power supply box and align its hinges.
4. When the hinges are aligned, release the top hinge pin to
engage its mating hinge on the power box. Then release
the bottom hinge pin from the hinge pin stop to complete
attaching the cover door to the power supply box.
NOTICE!
After all wiring is complete, close the cover door and tighten
the two (2) captive screws on the cover door to 10-12 N-m (90-
105 in.-lbs) to ensure the power supply box is watertight.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
18 en | Installing the Power Supply Box
AutoDome Power Supply Boxes
2.4
Route Wires and Attach Connectors
Power wires must be routed to the left (front) side of the
power supply box through a separate conduit. All video,
control, and alarm wires must be routed through a second
conduit to the right side of the box. Refer to Section 3 Cable and
Wire Standards, page 24 for methods of transmitting video and
data, and for wire specifications.
WARNING!
External interconnecting cables are to be installed in
accordance to NEC, ANSI/NFPA70 (for US application) and
Canadian Electrical Code, Part I, CSA C22.1 (for CAN
application) and in accordance to local country codes for all
other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed
Circuit Breaker or Branch Rated Fuses are required as part of
the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be
incorporated.
2.4.1
Methods for Routing Wires
There are two possible methods to route the video, control, and
alarm wires:
–
One is to route the video, control, and alarm wires through
the conduit fitting on the right (front) side of the power
supply box and out to the AutoDome Arm Mount or to the
Interface Board (for Pipe and Roof Parapet mounts).
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Installing the Power Supply Box | en 19
J102
P101
(LED)
24V NC 24V
P106
P105
GND TXD RXD ꢀꢀ C+ C-
GND TXD RXD ꢀꢀ C+ C-
Figure 2.3 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box
1 24/120/230 VAC
5 Coax, UTP Video, or Ethernet Wire
Power In
(Ethernet for VG5 700 Series only)
2 P101 Connector
6 Control Wire
3 Ground Connection 7 24 VAC Power Out
4 Transformer 8 P107 Connector
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
20 en | Installing the Power Supply Box
AutoDome Power Supply Boxes
–
The second method is to bypass the power supply box and
route the video, control, and alarm wires directly to the
AutoDome Arm Mount, Pipe Mount, or to the Roof Parapet
Mount. You connect only the power wires inside the power
supply box.
BNC
AGND
OUT
OUT
OUT
3
2
1
J102
AGND
A7
A6
A5
A4
A3
P101
(LED)
24V NC 24V
P106
P105
GND TXD RXD ꢀꢀ C+ C-
GND TXD RXD ꢀꢀ C+ C-
J 1 0 1
P 1 0 6
Figure 2.4 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box Connected to
Pipe Interface Board
VG4-A-PSU1/PSU2
24/12/230 VAC Power In 7
P101 Connector
Ground Connection
Pipe Interface Board
P101 Connector
P107 Connector
24 VAC Power In
1
2
3
8
9
(to AutoDome)
4
5
Transformer
24 VAC Power Out
10 Earth Ground
11 24 VAC Power In
(to AutoDome)
6
P107 Connector
12 24 VAC Power In (to Heater)
13 24 VAC Power In (to Heater)
14 AutoDome Power
15 Heater Power
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Installing the Power Supply Box | en 21
2.4.2
Wiring the Power Supply Box
1. Route the high voltage 115/230 VAC lines through the
conduit fitting on the left side of the box.
or
Route the 24 VAC lines through the conduit fitting on the
left side of the box.
NOTICE!
The power supply box with transformer comes with a barrier
that separates the high voltage side on the left from the low
voltage 24 VAC side on the right.
2. Cut and trim the high voltage 24/115/230 VAC power and
ground wires with sufficient slack to reach their connector
terminal in the box, but not so long as to be pinched by or
to obstruct closing the cover door.
3. Attach the supplied 3-pin power plug to the incoming high
voltage power wires in the box. Refer to connector P101 in
Table 2.1, Page 23.
4. Analog AutoDome: If you are using UTP for video, route
the UTP cable out to where the AutoDome will be
mounted. Refer to Section 3 Cable and Wire Standards,
page 24 for fiber optic specifications.
5. IP AutoDome: Route the Ethernet cable out to where the
AutoDome will be mounted. Refer to Section 3 Cable and
Wire Standards, page 24 for specifications.
6. Route the low power 24 VAC wires from the right side of
the power supply box out to where the AutoDome will be
mounted. Attach the supplied 5-pin 24 VAC Dome plug to
the wire ends inside the box. Refer to connector P107 in
Table 2.1, Page 23.
NOTICE!
All video, control, and alarm wires either pass through the
power supply box or by-pass it and connect directly to the Pipe
Interface Board.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
22 en | Installing the Power Supply Box
AutoDome Power Supply Boxes
2.4.3
Power Supply Box Connections
The following figure is a detailed illustration of the power
supply box, which includes the fuse specifications.
J102
P101
(LED)
CONTROL
IN/OUT
P106
CONTROL
TO DOME
P105
24V NC 24V
1 2 3
GND TXD RXD
C+ C-
GND TXD RXD
C+ C-
6
5
4
3
2
1
6
5
4
3
2
1
1
2
Ground Screw
Transformer
5
6
Power In
In/Out; 1/2 in.
(115/230 VAC Modes)
In/Out to Dome
(15 mm) NPS Fitting
Power In; 3/4 in.
3
4
7
8
(20 mm) NPS Fitting
Control Data and Video In/Out;
24 VAC to Dome
Interface Board
3/4 in. (20 mm) NPS Fitting
WARNING!
Fuse replacement by qualified service personnel only. Replace
with same type fuse.
Fuse Specifications
Volts
24 V
XF101 Mains
T 5.0 A
XF102 Camera XF103 Heater
T 2.0 A
T 2.0 A
T 2.0 A
T 3.15 A
T 3.15 A
T 3.15 A
115 V
230 V
T 1.6 A
T 0.8A
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Installing the Power Supply Box | en 23
The following table lists the Power Supply Box connectors:
No.
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Ground
Grounding Screw
P101 115/230 VAC
or 24 VAC
Line
NC
Neutral
Power In
P1051
P1061
Control to
C-
C+
Earth
RXD (+)
TXD (-)
Signal
Groun
Dome (Fiber
Optic Model)
(Biphase) (Biphase) Ground (RS-232/485) (RS-232/485)
d
Control In/Out C-
C+
Earth
RXD (+)
TXD (-)
Signal
Groun
(Optional) (Biphase) (Biphase) Ground (RS-232/485) (RS-232/485)
d
P107 24 VAC Power Dome
to Dome Plug 24 VAC
Dome
Earth
Heater
Heater
24 VAC
Ground (24 VAC)
(24 VAC)
1. Applicable to VG5 100 and 600 Series AutoDomes only.
Table 2.1 Power Box Connections
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
24 en | Cable and Wire Standards
AutoDome Power Supply Boxes
3
Cable and Wire Standards
CAUTION!
Installation should only be performed by qualified service
personnel in accordance with the National Electrical Code or
applicable local codes.
CAUTION!
All wires for installation applications must be routed through a
grounded conduit.
3.1
3.2
Power
24/115/230 VAC
Copper Wire
To comply with local codes.
Wire Distance Guide
24 V to AutoDome
VA /
14 AWG (2.5
16 AWG (1.5 18 AWG (1.0 mm)
mm)
Watts
mm)
AutoDome 100, Indoor
14 / 7.5
248 m (813 ft)
74 m (242 ft)
156 m (512 ft)
46 m (152 ft)
98 m (322 ft)
29 m (96 ft)
AutoDome 100, Outdoor 47 / 43.5
AutoDome 600, Indoor
AutoDome 600,
27 / 15
55 / 51
129 m (422 ft)
63 m (207 ft)
81 m (265 ft)
40 m (130 ft)
51 m (167 ft)
25 m (82 ft)
Outdoor1
AutoDome 700, Indoor
AutoDome 700,
35 / 19
60 / 55
99 m (325 ft)
58 m (190 ft)
62 m (205 ft)
36 m (119 ft)
39 m (129 ft)
23 m (75 ft)
Outdoor2
1. Standard heater module. Add Add 16 W if using VG4-SHTR-XT kit.
2. Standard heater module. The VG4-SHTR-XT kit is not applicable to VG5 700 Series
AutoDomes.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 25
3.3
Video and Control Cables
3.3.1
Using Coaxial Cable to Transmit Video and Control
CAUTION!
600 Series AutoDome: If you are using coaxial cable to transmit
video and data between the AutoDome and the head-end, you
must use the coax cable with ferrite included in the AutoDome
packaging. You must connect the incoming coax cable (from the
head-end) to the jack (female end) on the ferrite cable and
connect the plug end (male connector) of the ferrite cable to
the AutoDome’s coax connector.
^00600
Coaxial cable terminated with BNC connectors is the most
common method for transmitting composite video. Bilinx
control data can also be sent over the same cable.
Bilinx is a Bosch 2-way communication protocol that allows
remote control, configuration, and updates over a video coax
cable. Bilinx is available on all VG5 100 and 600 Series
AutoDomes.
VG5 Series AutoDomes feature cable compensation or “Pre-
Comp,” which extends the range of video from the head end.
Cable
Maximum Distances
Compensation
Video Only
Bilinx Control
Cable Type
RG-59/U
RG-6/U
RG-11/U
Size
Pre-comp OFF
Pre-comp ON
Pre-comp ON or OFF
300 m (1000 ft) 600 m (2000 ft) 300 m (1000 ft)
450 m (1500 ft) 900 m (3000 ft) 450 m (1500 ft)
600 m (2000 ft) 1200 m (4000 ft) 600 m (2000 ft)
O.D. between 4.6 mm (0.181 in.) and 7.9 mm (0.312 in.)
Copper braid: 95%
Shield
Central Conductor Standard copper center
Terminal Connector BNC
WARNING!
Cable compensation (Pre-Comp) does not extend the range of
Bilinx control. Pre-Comp is not available with VG5 700 Series
AutoDomes.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
26 en | Cable and Wire Standards
AutoDome Power Supply Boxes
3.3.2
Using UTP to Transmit Video and Control
Unshielded twisted pair (UTP) cable terminated with RJ45 male
connectors are used to transmit composite video using pins
1(+) and 2(-). Typically, a Coax to UTP cable converter is
required at the head-end of the system.
Bilinx control data can also be sent over the same two video
wires (1 & 2). Bilinx is a Bosch 2-way communication protocol
that allows remote control, configuration and updates over a
passive UTP cable.
VG5 100 and 600 Series AutoDomes feature cable
compensation or “Pre-Comp,” which extends the normal range
of control from the head end.
WARNING!
Do not connect the RJ45 connector unless using UTP video.
Cable Compensation
Maximum Distance
Cable Type
CAT5 UTP
Pre-comp OFF Pre-comp ON
229 m (750 ft) 450 m (1500 ft)
Terminal Connector RJ45
Requirement
Coax to UTP Converter
The following figure illustrates the connections necessary to
transmit video and control over a UTP cable.
1(+) &
+
-
RJ4
Figure 3.1 Video and Control over UTP
1
2
Head End Video
Coax
3
4
Pins
AutoDome
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 27
3.3.3
Using Ethernet to Transmit Video and Control
CAUTION!
Ethernet connections must be made to non-exposed (indoor)
networks only.
The AutoDome VG5 700 series connects to a 10 Base-T/100
Base-TX network either directly or via a switch. Both video and
control are transmitted over a standard TCP/IP network using
the built-in Web server.
Cable Type
Maximum Distance
Bandwidth
CAT-5E or CAT 6 Ethernet
100 m (328 ft)
10 Base-T/100 Base-TX
Terminal Connector RJ45, Female
WARNING!
Do not connect a coaxial cable while the RJ45 Ethernet cable is
connected.
3.3.4
Using Multi-mode Fiber Optic to Transmit Video
and Control
Fiber Optic kits, available for AutoDome 100 and 600 Series
cameras, transmit both video and Biphase control over an
analog singlemode or multimode fiber.
Multimode
Fiber Type
50/125 µm, 62.5/125 µm, low loss multimode glass
fiber
Maximum Distance
4 km (2.5 miles)
Minimum Bandwidth 20 MHz (Video - 850 nm / Control - 1300 nm)
Requirement
Bosch LTC 4629 Fiber Receiver at controller end of
system
Terminal Connector ST
Singlemode
Fiber Type
Maximum Distance
9/125 µm, low loss single glass fiber
69 km (43 miles)
Minimum Bandwidth 20 MHz (Video - 1310 nm /Control - 1550 nm)
Requirement
Single mode fiber receiver at controller end of
system
Terminal Connector ST
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
28 en | Cable and Wire Standards
AutoDome Power Supply Boxes
3.3.5
Using a Fiber Optic Ethernet Media Converter to
Transmit Video and Control
The fiber optic media converter kit, available for AutoDome 700
Series cameras, is designed to transmit 10/100 Mbps Ethernet
signals over fiber optic cable using 10/100 Mbps Small Form-
factor Pluggable (SFP) modules. The SFP modules are available
as multi-mode fiber (MMF) or single-mode fiber (SMF) models
with a single SC connector or dual-fiber with an LC connector.
Refer to the VG4-SFPSCKT Fiber Optic Media Converter
Installation Guide.
Ethernet Media Converter
Data Interface
Data Rate
Ethernet
10/100 Mbps
IEEE 802.3 Compliant
Full Duplex or Half Duplex Electrical Port
Full Duplex Optical Port
Fiber Type, MMF 50/125 µm MMF. For 50/125 µm fiber, subtract 4 dB
from the specified optical budget value. Must meet or
exceed fiber standard ITU-T G.651.
Fiber Type, SMF
8–10/125 µm SMF. Must meet or exceed fiber standard
ITU-T G.652.
Maximum Distance 60 km (37.3 miles)
Requirement
Media converter receiver (CNFE2MC/IN) at controller
end of system
Terminal
Duplex LC or Single SC
Connection
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 29
3.4
Control-only Cables
3.4.1
Controlling the AutoDome via Biphase
(Shielded 2-wire, half-duplex, multi-drop, 5000 ft. cable limit)
Biphase is the standard Bosch protocol used to send Pan/Tilt/
Zoom control over 2-wire shielded twisted pair (STP)
terminated with a 100 Ω terminal resistor.
The AutoDome has a 100 Ω termination resistor between the
Biphase C+ and C- terminals.
CAUTION!
The Biphase shield must be connected to the head end only.
Cable Type
STP - Shielded Twisted Pair
Distance
1524 m (5000 ft) Belden 8760 recommended
Transmission Rate
Gage
Termination
31.25 KHz
1.02 mm (18 AWG)
100 Ω
Terminal Connector Screw terminals
Voltage
4 Vp-p
The figure below illustrates the connections necessary for
Biphase operation.
100 Ω
Figure 3.2 Connections for Biphase Operation
1 C- (Biphase)
2 C+ (Biphase)
3 Earth Ground
7
8
9
AutoDome Data In/Out
Head End Biphase
P105/P106 Connector in Power Supply
Box
4 RxD
5 TxD
10 C- (Biphase)
11 C+ (Biphase)
6 Signal Ground 12 Shield
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
30 en | Cable and Wire Standards
AutoDome Power Supply Boxes
In a daisy chain configuration, where multiple domes are
connected in series, the 100 Ω resistor must be removed from
all but the last dome. You can daisy chain a maximum of four (4)
AutoDomes.
100 Ω
Figure 3.3 Connections for a Daisy Chain Configuration
1
2
3
4
5
6
7
8
C- (Biphase)
C+ (Biphase)
Earth Ground
RxD
TxD
Signal Ground
Last Dome Data In/Out
P105/P106 Connector in Power
9
Dome 3
10 Dome 2
11 Dome 1
12 Head End Biphase
13 C- (Biphase)
14 C + (Biphase)
15 Shield
Supply Box
3.4.2
Controlling the AutoDome via the RS232 Protocol
(3-wire, full-duplex, single-ended, 50 ft. cable limit)
RS232 is a common, single-ended communication protocol
used for control. Data transmission via 3-wires (TDX, RXD,
common) is from one transmitter to one receiver at relatively
slow baud rates (up to 57.6 Kbaud) and short distances up to
50 ft.
NOTICE!
After making the wire connections for RS232 operation,
reposition the slide switch located on the CPU Module to the
camera head inward and away from the LEDs.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 31
Wire Type
3-wire (TXD, RXD, common)
Distance
15 m (50 ft)
Maximum Baud Rate 57.6 Kb
Voltage
15 V
Termination
Slide Switch
100 Ω
Away from LEDs (factory default)
Figure 3.4 Connections for RS232 Operation
1
2
C- (Biphase)
C+ (Biphase)
7
8
AutoDome Data In/Out
P105/P106 Connector in Power
Supply Box
3
4
5
6
Earth Ground
RxD
TxD
9
Head End RS232
10 TxD
11 RxD
Signal Ground 12 Ground
Figure 3.5 Position of CPU Switch for RS232 Operation (camera module
not shown for clarity)
1
2
3
4
Switch Location
LEDs
RS232
CPU Module
Note: To access the CPU switch you must remove the bubble
from the pendant housing.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
32 en | Cable and Wire Standards
AutoDome Power Supply Boxes
3.4.3
Controlling the AutoDome via the RS485 Protocol
2-wire (shielded), half-duplex, differential, multi-drop (32
nodes), 4000 ft cable limit)
RS485 is capable of controlling a true multi-drop network and is
specified for up to 32 drivers and 32 receivers on a single 2-
wire bus. The AutoDome uses the 2-wire mode, although RS485
can be connected in a 2- or 4-wire mode.
NOTICE!
The wire shield must be tied to signal at both ends, if 2-wire
twisted pair is used. After connecting the wires for RS485
operation, make sure the slide switch on the main board to the
camera head is positioned toward the LEDs (default).
CAUTION!
Bosch recommends that multiple RS485 connections be
arranged as a connected series of point-to-point (multi-
dropped) nodes, as a line or as a bus. It is not recommended to
arrange RS485 connections as a star, ring, or as a multiple-
connected network. Star and ring topologies may cause signal
reflections or excessively low or high termination impedance.
Wire Type
Distance
Maximum Baud Rate
Gage
Wire Impedance
Slide Switch
2-wire shielded twisted pair
1219 m (4000 ft)
57.6 kb
0.511 mm (24 AWG)
120 W
Toward LEDs (factory default)
The following figure illustrates the connections for RS485
connections.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 33
100 Ω
Figure 3.6 Connections for RS485 Operations
1 C- (Biphase)
2 C+ (Biphase)
7
8
AutoDome Data In/Out
P105/P106 Connector in Power Supply
Box
3 Earth Ground
4 RxD
5 TxD
9
Head End RS485
10 Data +
11 Data -
6 Signal Ground 12 Ground
Figure 3.7 Position of CPU Switch for RS485 Operation (camera module
not shown for clarity)
1
2
3
4
Switch Location
LEDs
RS485
CPU Module
Note: To access the CPU switch you must remove the bubble
from the pendant housing.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
34 en | Cable and Wire Standards
AutoDome Power Supply Boxes
3.5
Fiber Optic Module with an RS232/RS422
Controller
An AutoDome with a fiber optic module is prewired to operate
with Biphase signals only. This section describes the
procedures necessary to control a VG5 series AutoDome fitted
with a fiber optic kit using an RS232 controller or a Pelco®
RS422 controller.
To control a VG5 Series Autodome from an RS232 or from a
Pelco RS422 controller you must run control wires from the
controller to an LTC 4629 head-end fiber optic module.
3.5.1
3.5.2
Connecting to an LTC 4629 Head End Data/Video
Transceiver
1. Connect the RS232 cable (TxD from the controller) to the
RS232 RxD port (pin 1) of the LTC 4629.
2. Connect the ground wire of the controller to Pin 2 on the
LTC 4629.
Configuring the VG5 AutoDome
1. Disconnect the power to the VG4 power supply unit; then
open the unit.
2. Remove the green Serial Communications wire from the
P106 connector.
3. Remove the 100 Ω resistor across the C+ and C- pins.
4. Cut the five wires from the green Serial Communications
wire mating connector.
Ensure that the insulation covers each wire to avoid wires
from touching.
5. Cut back the insulation on the blue (ground) wire and on
the green (RxD) wire enough to be able to connect these
wires back into the P106 connector.
6. Connect the blue (ground) wire to the C- pin on the P106
connector.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 35
7. Connect the green (RxD) wire to the C+ pin on the P106
connector.
24 VAC
P101
(LED)
24V NC 24V
P106
P105
GND TXD RXD
C+ C-
GNDTXD RXD
C+ C-
Figure 3.8 Detail of P106 Connections
1
2
Green RxD wire connected to C+
Blue Ground wire connected to C-
8. Connect the fiber optic cable from the AutoDome to the
LTC 4629.
9. Close the door to the power supply unit.
10. Ensure that the VG5 AutoDome is set to receive RS232
commands.
–
–
–
Remove the bubble from the VG5 AutoDome housing.
Locate the protocol switch on the CPU board.
Ensure that the protocol switch is in the left position
for RS232 operation.
Figure 3.9 Position of CPU Switch for RS232 Operation
1
2
3
4
Switch Location
LEDs
Move Switch to the left for RS232 Operation
CPU Module
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
36 en | Cable and Wire Standards
AutoDome Power Supply Boxes
11. Return the bubble to the AutoDome housing.
12. Return power to the power supply box.
3.6
Audio Cables
The VG5 700 Series AutoDome is capable of receiving line input
audio signals and transmitting it over a network. The audio
signal is transmitted one-way and in sync with the video signals.
Audio Line Input Specifications
Max. Input Voltage
Impedance
5.5 Vpp
9K Ω
Sample Rate
Shield
8 K Hz, 16 Bit, mono
Bare copper braid: 95% coverage
Internal gain level adjustment is available
Wire Specifications
3
Wire Type
Coax (recommended)
Distance
Gage
Shield
10 m (33 ft)
22 AWG to Biphase connector (P105/P106)
Bare copper braid: 95% coverage
Center conductor Stranded bare copper
NOTICE!
Separate the audio cables from the AC power lines to avoid
noise.
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoDome Power Supply Boxes
Cable and Wire Standards | en 37
Audio Connections
1. Remove the 100 Ω termination resistor from the Biphase
terminals.
2. Connect the audio line level source to the Biphase C+ input
terminal.
3. Connect the audio signal ground to the Biphase C- input
terminal.
The following figure illustrates the connections for audio
over an IP network.
Figure 3.10 Connections for audio over an Ethernet network
1
2
3
4
5
6
C- (Biphase)
C+ (Biphase)
Earth Ground
RxD
TxD
Signal Ground
7
8
9
AutoDome Data In/Out
P105/P106 Connector
Audio Out
NOTICE!
Refer to the VG5 700 Series AutoDome User Manual for
configuring and using audio over an IP Ethernet network.
Bosch Security Systems, Inc.
Installation Guide
F.01U.250.895 | 1.0 | 2011.08
Download from Www.Somanuals.com. All Manuals Search And Download.
38 en | Cable and Wire Standards
AutoDome Power Supply Boxes
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Security Systems, Inc.
850 Greenfield Road
Lancaster, PA 17601
U.S.A.
© Bosch Security Systems, Inc., 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
|