1. Multi-pole switch  
2. Terminal block  
3. Thermostat  
5. Switches  
6. LED Light  
7. Heating elements  
8. Pressure switch  
8
6
7
4. Microswitch  
Table 2  
kW loading  
220V 230V 240V  
3.0 3.3 3.6  
3.2 3.5 3.8  
5.0 5.5 6.0  
5.5 6.0 6.6  
7.0 7.7 8.3  
7.3 8.0 8.7  
8.7 9.5 10.3  
Recommended  
cable size  
Recommended  
fuse rating  
Model  
Heat Setting  
New/Lotus - 3.0  
New/Lotus - 3.5  
New/Lotus - 5.0  
New/Lotus - 5.5  
New/Lotus - 7.0  
New/Lotus - 8.0  
New/Lotus - 9.5  
1.0;2.0 or 3.0kW  
1.5;2.0 or 3.5kW  
2.0;3.0 or 5.0kW  
2.5;3.0 or 5.5kW  
3.0;4.0 or 7.0kW  
4.0;4.0 or 8.0kW  
4.5;5.0 or 9.5kW  
2.5mm2  
2.5/4mm2  
4/6mm2  
4/6mm2  
6/10mm2  
6/10mm2  
10mm2  
16amps  
20amps  
25amps  
25-32amps  
40amps  
40amps  
45amps  
• Operating water pressure 0.3-7 BAR (5-100 psi) Water pressure operating power switch  
• Standard 1/2"Ø compression inlet connection Top-left and right cable entry • Bottom-left water entry  
Installation Instructions  
UNIT DIMENSIONS: HEIGHT 185mm WIDTH 300mm DEPTH 110mm  

Toshiba Series Hard Disk Drive PX02SMB160 User Manual
Superior K310I User Manual
Sony CDP XB820 User Manual
Seagate ST480FP0021 User Manual
Seagate MOMENTUS ST910021AS User Manual
Samsung SGH U800 User Manual
Rosewill Computer Drive RHB 620 User Manual
Philips CD 824 User Manual
Philips AJ3290 User Manual
Oregon Scientific RRM326P User Manual