Whirlpool Clothes Dryer WGD9450W User Manual

Duet Steam and Non-Steam Electronic Gas Dryer  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
Custom undercounter installation-dryer only  
Dryer dimensions  
WGD9450W, WGD9470W, WGD9550W,  
STEAM - 529/16  
"
(1335 mm)  
WGD9600T, WGD9750W, WGD9610X  
NON-STEAM - 511/2  
(1308 mm)  
"
Gas supply: This dryer is equipped for use with Natural  
gas. Dryer can be converted to L.P. gas. When rigid  
pipe is used it should be 1/2" IPS. When acceptable  
to the gas supplier and local codes, 3/8" approved  
tubing may be used for lengths under 20 ft (6.1 m).  
For lengths over 20 ft (6.1 m), larger tubing should be  
used. Pipe-joint compounds resistant to the action of  
L.P. gas must be used. An individual manual shutoff  
valve must be installed within 6 ft (1.8 m) of the dryer  
in accordance with the National Fuel Gas Code ANSI  
Z223.1.  
38  
"
(965 mm)  
38  
"
27  
"
1
"*  
1
"*  
(965 mm)  
(686 mm)  
(25 mm)  
(25 mm)  
Most installations require a minimum  
5" (127 mm) clearance behind the dryer for  
the exhaust vent with elbow. See Installation  
Instructions, “Venting Requirements.”  
*STEAM - 329/16  
(827 mm)  
"
27  
"
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp  
fused electrical supply is required for gas dryers, 30  
amp for electric dryers. A time-delay fuse or circuit  
breaker and a separate circuit are recommended.  
(686 mm)  
NON-STEAM - 311/2  
(800 mm)  
"
For closet installation, with a door, the minimum ventilation openings in the top and  
bottom of the door are required. Louvered doors with equivalent air  
ventilation openings are acceptable.  
Water (Steam models only): The dryer must be  
connected to the cold water faucet using new inlet  
hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.  
6
"
(152 mm)  
Exhaust venting: Exhaust your dryer to the outside.  
4" (102 mm) diameter vent is required. Rigid or flexible  
metal exhaust vent must be used. Do not use plastic  
or metal foil vet. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.  
3
"
(76 mm)  
14" max.  
(356 mm)  
48 in.2 *  
(310 cm2)  
18" max.  
(457 mm)  
76  
"
(1930 mm)  
Hood styles: A & B are recommended.  
4"  
B
C
(102 mm)  
24 in.2 *  
3
"
(155 cm2)  
(76 mm)  
A
1
"
27  
"
1"  
(25 mm) (686 mm) (25 mm)  
2½"  
(64 mm)  
STEAM - 329/16  
"
STEAM - 51/2"**  
(140 mm)  
NON-STEAM - 5"**  
(127 mm)  
(827 mm)  
4"  
(102 mm)  
NON-STEAM - 311/2  
"
A. Louvered hood  
B. Box hood  
(800 mm)  
4"  
(102 mm)  
C. Angled hood (acceptable)  
For dryer on pedestal; cabinet installation, with a door, the minimum ventilation  
openings in the top are required.  
The vent system chart provides venting requirments  
that will help to achieve the best drying performance.  
7
"*  
7"*  
(178 mm)  
Vent system chart:  
(178 mm)  
NOTE: Side and bottom exhaust installations have  
a 90° turn inside the dryer. To determine maximum  
exhaust length, add one 90° turn to the chart.  
14"* max.  
(356 mm)  
Box or  
Louvered  
hoods  
Number of  
90o turns  
or elbows  
Type of  
vent  
Angled  
hoods  
18"* max.  
(457 mm)  
9
"*  
(229 mm)  
64 ft (20 m)  
0
58 ft (17.7 m)  
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
54 ft (16.5 m)  
44 ft (13.4 m)  
35 ft (10.7 m)  
1
2
3
48 ft (14.6 m)  
38 ft (11.6 m)  
29 ft (8.8 m)  
1
"*  
27"  
1"*  
Rigid metal  
27 ft (8.2 m)  
4
21 ft (6.4 m)  
(25 mm) (686 mm) (25 mm)  
5
"
STEAM - 329/16  
"
(127 mm)  
(827 mm)  
NON-STEAM - 311/2  
"
(800 mm)  
33/8  
"
37/16"  
*Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed.  
(86 mm  
1
"
(87 mm)  
1"  
(25 mm)  
Select the route that will provide the straightest and most direct path outdoors.  
Plan the installation to use the fewest number of elbows and turns.  
Use the fewest 90° turns possible.  
(25 mm)  
75/8  
"
14  
"
Do not use vent runs longer than specified in vent length chart.  
Determine the number of elbows you will need.  
(356 mm)  
(194 mm)  
Side View  
Back View  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
W10255469B  
06/2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Wharfedale Microphone DM 20 User Manual
Whirlpool Refrigerator WRS325FNAM User Manual
Whirlpool Washer Accessories W10178072B User Manual
Williams Sound Stereo System R1 216 User Manual
Winegard TV Antenna GM 1518 User Manual
Wolf Cooktop ICBCT15E User Manual
Zanussi Dishwasher DA 6152 User Manual
Zanussi Oven ZPB 1260 User Manual
Zanussi Refrigerator ZT 56 User Manual
Zenoah Trimmer EHT603D User Manual