LRS-24
12-slot Link Access Rack with SNMP
Version 3.00
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this
publication may be reproduced in any form whatsoever without prior written approval by RAD Data
Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in
this manual is made either by RAD Data Communications or its agents.
For further information contact RAD Data Communications at the address below or contact your local
distributor.
RAD Data Communications
Headquarters
RAD Data Communications
US East
RAD Data Communications
US West
12 Hanechoshet Street
Tel Aviv 69710 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
E-mail: [email protected]
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Fax: (201) 529-5777
E-mail: [email protected]
3631 South Harbor Boulevard
Suite 250
Santa Ana, CA 92704
Tel: (714) 850-0555
Fax: (714) 850-1555
© 2000 RAD Data Communications
Publication No. 695-211-08/00
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Warranty
This RAD product is warranted against defects in material and workmanship for a period of one year
from date of shipment. During the warranty period, RAD will, at its option, either repair or replace
products which prove to be defective. For warranty service or repair, this product must be returned to
a service facility designated by RAD. Buyer shall prepay shipping charges to RAD and RAD shall pay
shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties
and taxes for products returned to RAD from another country.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance
by Buyer, Buyer-supplied firmware or interfacing, unauthorized modification or misuse, operation
outside of the environmental specifications for the product, or improper site preparation or
maintenance.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. RAD shall not be liable for
any direct, indirect special, incidental, or consequential damages, whether based on contract, tort, or
any legal theory.
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Safety Warnings
SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY!
The exclamation point within a triangle is intended to warn the operator or
service personnel of operation and maintenance factors relating to the
product and its operating environment which could pose a safety hazard.
Always observe standard safety precautions during installation, operation and maintenance of this
product. Only a qualified and authorized service personnel should carry out adjustment, maintenance
or repairs to this instrument. No adjustment, maintenance or repairs should be performed by either the
operator or the user.
Telecommunication Safety
1. The unit should be installed within 1.5m (5 feet) of a grounded, easily accessible AC outlet, or in
an adequately earthed rack mount. If the protective earth connection is not guaranteed by the
mains supply, the unit must be externally connected to a reliable protective earth. DC powered
units must be connected only to power sources which conform to the relevant safety standard.
2. In order to guarantee an uninterrupted flow of air stream, leave at least 15 mm spacing above
and below the top and bottom sides of the unit. The recommended maximum temperature of the
surrounding area is 40°C.
3. Vacant slots must always be covered with blank covers. This is necessary in order to guarantee a
definite cooling stream of air and to prevent unintentional and unauthorized access inside the
equipment.
4. The safety status of the ports on the LRS-24 is declared according to EN 41003 and is detailed in the
table below. Interconnection of these ports with other apparatus should be made so that the
equipment continues to comply with the requirements of EN 60950 connection of SELV and TNV
circuits to other circuits after such a connection is made.
Ports
Safety Status
V.24, V.35, V.36, X.21, RS-530,
Unbalanced E1, E&M
SELV
Circuit operating with Safety Extra-Low Voltage
Baseband modems, ISDN,
Balanced E1, T1, HDSL
TNV-1
Circuit whose normal operating voltage is within
the limits of SELV, on which overvoltages from
Telecommunications Networks are possible.
FXS
TNV-2
TNV-3
Circuit whose normal operating voltage exceeds
the limits of SELV, on which overvoltages from
Telecommunications Networks are not possible.
FXO, Ports with remote power
feeding (phantom)
Circuit whose normal operating voltage exceeds
the limits of SELV, on which overvoltages from
Telecommunications Networks are possible.
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Additional conditions concerning the safety of connection to telecommunication networks:
• The unit must be earthed prior to connection to telecommunication networks.
• The signal ground of the SELV circuits is connected at the factory to the protective earth.
Interrupting this connection may invalidate the safety of the connection to unprotected
telecommunication networks in certain locations where permanent excessive voltages are
present on the lines.
• In order to comply with the requirements set out in EN 60950 for TNV-3 circuits, the maximum
phantom supply voltage must not exceed 120 VDC. The remote power feeding supply must be
floating and must comply with the requirements for TNV-3 circuits.
• DC powered units must be powered from EN 60950 or UL-1950 approved power source. In
order to avoid a fire hazard, a suitable fuse or circuit breaker must be installed on the
non-earthed DC line.
Regulatory Information
FCC-15 User Information
This equipment has been tested and found to comply with the limits of the Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to the radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Warning per EN 55022
This is a Class A product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
LRS-PS-FEED Output Voltage
The output voltage of the LRS-PS-FEED exceeds the limits of TNV-3 circuits. In the event of uncertainty
about the regulatory status of connecting such voltages to leased lines provided by certain service
providers, consult with a safety engineer.
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Declaration of Conformity
Manufacturer’s Name:
RAD Data Communications Ltd.
Manufacturer’s Address:
12 Hanechoshet St.
Tel Aviv 69710
Israel
declares that the product:
Product Name:
LRS-24
Conforms to the following standard(s) or other normative document(s):
EMC:
EN 55022 (1994)
Limits and methods of measurement of radio disturbance
characteristics of information technology equipment.
EN 50082-1 (1992) Electromagnetic compatibility - Generic immunity
standards for residential, commercial and light industry.
Safety:
EN 60950/A4
Safety of information technology equipment, including
electrical business equipment.
Supplementary Information:
The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the
Low Voltage Directive 73/23/EEC. The product was tested in a typical configuration.
Tel Aviv, March 19th, 2000
Haim Karshen
VP Quality
European Contact: Rad Data Communications GmbH, Berner Strasse 77, 60437, Frankfurt am Main, Germany
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Quick Start Guide
If you are familiar with LRS-24, use this guide to prepare it for operation. Choose
the section appropriate to the version of LRS-24 you are using.
1. LRS-24 with CM-1 Module
This section contains the startup instructions for LRS-24 with the CM-1 module.
Power-On
➤ To turn the power on:
1. Set the ON/OFF switches on the panels of the LRSI-PSP** modules to ON.
2. Supply the DC power, as applicable.
➤ To supply external phantom feed voltages:
1. Turn on LRS-24.
2. Turn on the source (for example, LRS-PS-FEED).
Normal Indications
•
PS Module(s): All the indicators on the panel(s) of the PS module(s) must light
in green to indicate proper operation.
•
CM-1 Module: The POWER indicator of the module must light. The TD and
RD indicators may flash (or may light steadily) when a management session is
in progress.
LRS-24 with CM-2 Module
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Quick Start Guide
LRS-24 Installation and Operation Manual
2. LRS-24 with CM-2 Module
This section contains the startup instructions for LRS-24 with the CM-2 module.
Power-On
➤ To turn the power on:
1. Set the ON/OFF switches on the panels of the LRSI-PSP** modules to ON.
2. Supply the DC power, as applicable.
➤ To supply external phantom feed voltages:
1. Turn on LRS-24.
2. Turn on the source (for example, LRS-PS-FEED).
Normal Indications
•
PS Module(s): All the indicators on the panel(s) of the PS module(s) must light
in green to indicate proper operation.
•
CM-2 Module: The POWER indicator of the module must light. The TD and
RD indicators may flash (or light steadily) when a management session is in
progress.
Normally, the STAT/ADD display shows the two least significant digits of the
management number assigned to LRS-24. For normal startup, a rotating red circle
is displayed. However, if a problem is detected during the power-up self-test, you
will see a flashing error code (E1 through E9).
Preliminary Configuration
Perform preliminary configuration on the LRS-24 hub (see Chapter 4).
2
LRS-24 with CM-2 Module
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Contents
Chapter 1. Introduction
1.1 Overview.......................................................................................................... 1-1
General ...................................................................................................................1-1
Versions...................................................................................................................1-3
Application..............................................................................................................1-3
Features...................................................................................................................1-4
1.2 Physical Description.......................................................................................... 1-6
Chassis Description..................................................................................................1-6
LRS-24 Module Slots..............................................................................................1-10
1.3 Functional Description.................................................................................... 1-11
Power Supply (PS) Modules ...................................................................................1-11
Common Logic Modules........................................................................................1-12
Management .........................................................................................................1-13
I/O (User) Modules ................................................................................................1-14
1.4 Technical Specifications .................................................................................. 1-14
Chapter 2. Installation and Setup
2.1 Introduction...................................................................................................... 2-1
Mechanical Data......................................................................................................2-1
2.2 Site Requirements and Prerequisites.................................................................. 2-4
AC Power................................................................................................................2-4
DC Power................................................................................................................2-4
Grounding...............................................................................................................2-4
Interface Module Handling Precautions....................................................................2-4
Module Handling Precautions..................................................................................2-5
Front Clearance .......................................................................................................2-5
Ambient Requirements ............................................................................................2-5
Cooling....................................................................................................................2-5
2.3 Unpacking the Chassis ...................................................................................... 2-5
2.4 Installation and Setup........................................................................................ 2-6
PS Modules .............................................................................................................2-6
CM-1 Module..........................................................................................................2-8
CM-2 Module........................................................................................................2-12
2.5 Interfaces and Connections ............................................................................. 2-15
PS Interface Modules .............................................................................................2-16
LRSI-F-CM1...........................................................................................................2-17
LRSI-F-1-CM2 / LRSI-B-1-CM2 Interface Modules with 10BaseT.............................2-18
LRSI-F-2-CM2 Interface Module with 10Base2.......................................................2-21
LRS-24 Enclosure...................................................................................................2-24
2.6 Initial Operation and Basic Checks.................................................................. 2-27
LRS-24 with CM-1 Module ....................................................................................2-27
LRS-24 with CM-2 Module ....................................................................................2-28
LRS-24 Installation and Operation
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Table of Contents
Chapter 3. Management via the CM-1 Module
3.1 Introduction...................................................................................................... 3-1
CM-1 Functions.......................................................................................................3-1
Management Capabilities.........................................................................................3-1
3.2 Hardware Requirements ................................................................................... 3-2
Terminal Characteristics...........................................................................................3-2
Management RS-232 Port Interface Characteristics...................................................3-2
Connecting the Terminal..........................................................................................3-2
3.3 Operating the CM-1 Supervision Terminal ........................................................ 3-4
General ...................................................................................................................3-4
Configuring the Terminal .........................................................................................3-4
Performing Preliminary Configuration.......................................................................3-5
Configuring Individual Modules................................................................................3-5
Chapter 4. Management via the CM-2 Module
4.1 Introduction...................................................................................................... 4-1
CM-2 Module Capabilities .......................................................................................4-1
CM-2 Functions.......................................................................................................4-2
Handling of Management Communication...............................................................4-3
Management Priorities .............................................................................................4-4
Preliminary Configuration Activities..........................................................................4-4
Initializing CM-2......................................................................................................4-5
4.2 Hardware Requirements ................................................................................... 4-6
Terminal Characteristics...........................................................................................4-6
RS-232 Supervisory Port Interface Characteristics .....................................................4-7
Terminal Connection Methods.................................................................................4-7
Connection of Management Station ........................................................................4-7
4.3 CM-2 Supervision Terminal Language ............................................................. 4-11
General .................................................................................................................4-11
Index of Commands ..............................................................................................4-12
4.4 Supervision Terminal Operating Instructions.................................................... 4-13
General .................................................................................................................4-13
Configuring the Terminal .......................................................................................4-13
Changing the Password..........................................................................................4-14
Preliminary Configuration ......................................................................................4-14
Configuring Individual Modules..............................................................................4-14
Configuration by SNMP Network Management Stations .........................................4-15
Transferring Control to the Supervision Terminal ....................................................4-15
Chapter 5. Troubleshooting and Diagnostics
5.1 Alarms............................................................................................................... 5-1
5.2 Diagnostic Tests ................................................................................................ 5-1
5.3 Troubleshooting................................................................................................ 5-1
5.4 Error Messages .................................................................................................. 5-2
ii
LRS-24 Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Table of Contents
Appendix A. Connector Wiring
Appendix B. LRS-PS-FEED Power Supply
Appendix C. SNMP Management
Appendix D. CM-2 Management Commands
List of Figures
1-1. Backbone Data Distribution up to Customer’s Premises............................................. 1-3
1-2. Management of Local and Remote Distribution Nodes.............................................. 1-4
1-3. LRS-24B 3-D View .................................................................................................... 1-7
1-4. LRS-24B Enclosure .................................................................................................... 1-8
1-5. LRS-24F 3-D View..................................................................................................... 1-9
1-6. LRS-24F Enclosure................................................................................................... 1-10
1-7. LRS-24F Enclosure, Typical Front View.................................................................... 1-11
1-8. Basic Management Configuration for LRS-24 with CM-2 Modules........................... 1-14
2-1. LRS-24F Mechanical Diagram.................................................................................... 2-2
2-2. LRS-24B Mechanical Diagram ................................................................................... 2-3
2-3. PS Module Panels...................................................................................................... 2-7
2-4. Module CM-1 Front Panel......................................................................................... 2-9
2-5. Module CM-1, Internal Jumpers .............................................................................. 2-10
2-6. Module CM-2 Front Panel....................................................................................... 2-12
2-7. Module CM-2, Internal Jumpers .............................................................................. 2-14
2-8. LRSI-F-PSP/230/114 and LRSI-F-PS/48 Interface Module Panels .............................. 2-17
2-9. Typical LRSI-F-CM1 Interface Module Panel............................................................ 2-18
2-10. LRSI-F-1-CM2 / LRSI-B-1-CM2 Interface Module Panel with 10BT ........................ 2-19
2-11. Interface Module LRSI-F-1-CM2 with UTP Connector, Internal Jumpers................ 2-20
2-12. LRSI-F-2-CM2 Interface Module Panel with 10B2 ................................................. 2-22
2-13. Interface Module LRSI-F-2-CM2 with BNC Connectors, Internal Jumpers.............. 2-23
3-1. Typical Direct Connection of Supervision Terminal ................................................... 3-3
3-2. Typical Connection of Supervision Terminal Through Modem Link ........................... 3-4
4-1. Typical Direct Connection of Supervision Terminal ................................................... 4-8
4-2. Typical Connection of Supervision Terminal Through Modem Link ........................... 4-8
4-3. Typical Connection of Supervision Terminal Through Slip ......................................... 4-9
4-4. Typical Connection to Network Management Station.............................................. 4-10
4-5. Password Menu Screen ........................................................................................... 4-14
4-6. JP15 Settings............................................................................................................ 4-14
5-1. Error Indicators.......................................................................................................... 5-2
LRS-24 Installation and Operation
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Table of Contents
List of Tables
2-1. PS Modules, Front Panel Indicators............................................................................ 2-7
2-2. Module CM-1, Front Panel Components................................................................... 2-9
2-3. Module CM-1 Jumper Settings................................................................................. 2-11
2-4. Module CM-2, Front Panel...................................................................................... 2-13
2-5. Module CM-2 Jumper Settings................................................................................. 2-15
2-6. PS Interface Module Types...................................................................................... 2-16
2-7. Management 10BT Ethernet LEDs ............................................................................ 2-19
2-8. LRSI-F-1-CM2 Module Jumper Settings.................................................................... 2-21
2-9. LRSI-F-2-CM2 Interface Module Jumper Settings..................................................... 2-23
2-10. CM-2 Module STATION CLK Connector, Pin Allocation........................................ 2-26
2-11. CM-1 Module Management RS-232 Pin Allocation................................................. 2-27
4-1. Terminal Command Set Index for CM-2 Module...................................................... 4-12
4-2. Terminal Command Set Index for CM-2 Module (Cont.) ......................................... 4-13
5-1. Front Panel Indicator Displays ................................................................................... 5-2
5-2. Error Messages........................................................................................................... 5-3
iv
LRS-24 Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1
Introduction
This chapter describes the basic physical and functional features of the LRS-24
modem rack, as well as some typical applications. The following topics are
discussed:
•
•
•
•
Overview
Physical Description
Functional Description
Technical Specifications.
1.1 Overview
General
LRS-24 is a high-density SNMP managed modem chassis. The chassis has 12 slots
that accommodate up to 24 modems. Using modular interface cards, LRS-24 can
support xDSL, fiber or baseband modems in the same chassis under a single
management application.
Supporting different modem technologies enables a wide range of data-rates,
starting from 1.2 kbps in IDSL modems, through 2 Mbps with HDSL/fiber
modems, and up to 43 Mbps using fiber modems. This also enables ranges from
4.8 km at
2 Mbps over copper to 100 km over fiber modems.
LRS-24 is available in two different physical hub versions: LRS-24B (ANSI) or
LRS-24F (ETSI).
All cards can be replaced or cables removed during operation, without causing
interference to data transmission to/from other cards in the chassis.
Modular data interfaces allow modem connectivity via a wide range of data
interfaces. These include: V.24, V.35, X.21, RS-530, V.36, G.703 codirectional,
E1, built-in Ethernet bridge, or built-in IP router.
LRS-24 accepts a system clock via the DB-15 connector placed on the CM-2 card.
Overview
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
Management/CM-2 functions
LRS-24 is managed by a UNIX-based or PC-based SNMP management system via
the Central Management card (CM-2). The software is user-friendly,
GUI-based and runs under PC/Windows (RADview-PC) or HP OpenView
(RADview-HPOV) systems. Configuration and monitoring are also provided via
TELNET or ASCII terminal.
Network management provides centralized control of all LRS-24 hubs, modem
cards and remote modems in the network, including interface configuration,
connection setup, alarm and monitoring. A single management station can control
up to 64,000 LRS-24 hubs.
Direct 10BaseT Ethernet connection enables real-time management of central and
remote sites. Performance information is available in graph and table format for
the last 24 hours. This information can be saved in a file for accounting purposes.
If a major alarm occurs, the LRS-24 CM-2 card can dial out through an external
dial-up modem to a central management site. This saves a direct connection to
remote sites, while providing alerts if critical events occur. In addition alarms can
activate dry contacts. The dry contacts are placed on the system clock connector
on CM-2.
Two types of modem cards are available on the LRS-24:
•
•
S-Mode: Cards with a built-in SNMP agent
I-Mode: Cards without an SNMP agent. For these cards CM-2 serves as the
SNMP proxy agent. The CM-2 built-in agent complies with SNMP MIB II and
supports generic SNMP HPOV applications.
A new software version can be downloaded from a remote site onto the CM-2 via:
•
•
LAN by TFTP protocol
Terminal by XMODEM.
CM-2 saves up to three software versions.
When the management station includes BootP software, the CM-2 card
automatically retrieves the IP address required for management connection. This
eliminates the need to configure IP addresses for new hub installations.
LRS-24 can also be managed from an ASCII terminal. It allows all functions of
SNMP except for GUI interface. The connection is made via a V.24 supervisory
port using SLIP or PPP protocol.
Telnet support enables terminal connection over any IP network.
The CM-2 panel includes an alphanumeric display with two characters used for
alerting on fault conditions and for the hub IP address.
1-2
Overview
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 1 Introduction
Power Supplies
LRS-24 operates with single or dual, AC or DC power supplies. Each power supply
supports a full LRS-24 hub, including modem cards. Redundant power supply can
be replaced during operation, without affecting system performance
(hot-swapping).
Cards in the LRS-24 chassis are capable of providing remote power feeding for
repeaters and remote standalone modems. To provide remote power feeding
order a separate standalone power supply, LRS-PS-FEED.
Versions
Two different physical versions of the LRS-24 hub are available:
•
ANSI − card insertion, LEDs and switches are at the front, but cable
connections are at the rear of the hub. This compact, 4U high unit complies
with the American ANSI standard. Cards can be hot-swapped without
removing cables.
•
ETSI − card insertion, LEDs, switches and cable connections are at the front.
This version is 30 cm high (almost 6U), and complies with European ETSI
standard. Cards can be hot-swapped without removing cables.
Application
Figure 1-1 shows an application of Backbone Data Distribution up to Customer’s
Premises.
SNMP
Management
Station
HDSL
HCD-E1
ASMi-51
PABX
MSDSL
IDSL
LRS-24
ASMi-31-2
FOMi-E1/T1
FOMi-E3
Fiber
PABX
Fiber
HSSI
Router
Figure 1-1. Backbone Data Distribution up to Customer’s Premises
Figure 1-2 shows an application of Management of Local and Remote Distribution
Nodes.
Overview
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
Central
Management
Station
PSTN
Dial-up
Modem
ADM or
Frame Relay
Switch
LRS-24
LRS-24
Local SNMP
Management
Station
Backbone
Switch
ADM or Frame
Relay Switch
LRS-24
Modem
Router
PBX
LRS-24
PBX
Router
OP-XL
PBX
LRS-24
Switch
MP2100
Figure 1-2. Management of Local and Remote Distribution Nodes
Features
LRS-24 is a high-density, fully modular design with front-panel access to all the
functions. It supports up to 48 user modules in addition to redundant power
supply and management access modules.
It combines different technologies in a centrally-managed rack: DSL, fiber and
baseband.
LRS-24 offers single-point management access to the individual equipment
modules installed in the hub, and to the remote equipment units connected by
links to these modules. LRS-24 supports SNMP management, as well as
management by means of an ASCII terminal. No special software is required for
the terminal, which is controlled by the management software of the modules
installed in LRS-24.
Clock signals are distributed from an external source (station clock) to all the
equipment modules installed in the hub.
There is a standard set of regulated supply voltages. Power supply redundancy
ensures continuous availability of power.
The unit supports remote (phantom) feed of equipment connected to LRS-24.
The mechanical design separates user hardware modules from interface
(connector) modules, facilitates maintenance tasks.
The form factor is suitable for installation in standard 300 mm and 600 mm
ETSI racks; can be easily adapted for installation in 19" racks.
The flexible modular construction and management capabilities that are available
for the equipment installed in LRS-24 enable the user to easily configure individual
systems for specific requirements and applications.
1-4
Overview
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 1 Introduction
Remote Management
The modem cards in the LRS-24 can be remotely managed by the
RADview-HPOV SNMP management system, the PC-based RADview-PC/MDM
management system or by a dumb terminal. The same RADview application can
manage the LRS-24, modems in the hub and other RAD products.
Audible and visual indicators provide status of alarms and tests at the network,
card and port levels, and include all links connected to the hub. Alarms are
automatically logged and presented upon request, unless otherwise masked.
RADview-HPOV SNMP Management System
Both electrical and fiber optic modem cards can be managed by the
RADview-HPOV SNMP management system. All cards in the hub, except for
ASM-40CD, have remote control abilities for monitoring and/or controlling remote
units, and several types of cards contain an internal SNMP agent. In some cases,
managed cards can work opposite non-manageable modems.
RADview-HPOV management is available for modules with or without integrated
SNMP agent, via the SNMP Control Module (CM-2). The RADview-HPOV station
is connected to LRS-24 via an integrated Ethernet connection on the CM-2
module; CM-2 acts as a proxy SNMP agent for those cards without an agent.
RADview-PC/MDM Management System
The RADview-PC/MDM management station communicates with LRS-24 using
out-of-band communication via Ethernet.
The RADview-PC/MDM has a windows-based Graphical User Interface (GUI)
platform for LAN and WAN networks. The graphical user interface allows
configuration with easy-to-use operations on graphical representations of the hub.
The configuration can be performed at the port, card, hub and network levels.
Management by Dumb Terminal
LRS-24 can also be managed from a dumb terminal. Control Module CM-1 is used
for ASCII terminal management of modules with SNMP agent on-board, such as
HTU-E1C.
Clock
Both control modules, CM-1 and CM-2, have a station clock connection enabling
clock distribution to all cards, so that all cards can be synchronized to the same
station clock. Refer to the specific card operation manual for a description of
station clock support.
Power Supplies
LRS-24 operates with single or dual power supplies: AC or DC. Each power supply
supports a full rack of cards of any combination. The redundant power supply can
be replaced during operation, without affecting the system performance
(hot- swapping).
Overview
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
1.2 Physical Description
Chassis Description
There are two different physical versions of LRS-24: LRS-24B and LRS-24F.
LRS-24B ANSI UNIT
LRS-24B is a modular chassis suitable for installation in standard ANSI racks. It has
a height of 200 mm (4U). The chassis has physical slots arranged on the front and
back sides:
•
The front side accepts 4U-high functional modules (the modules that perform
the various processing functions).
•
The back side accepts 2U-high interface modules which contain the
connectors used to access the modules on the front side.
Figure 1-3 shows a 3-dimensional view of LRS-24B.
1-6
Physical Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 1 Introduction
Rear View
Front View
Figure 1-3. LRS-24B 3-D View
Figure 1-4 shows the LRS-24B enclosure with the Interface Modules, User
Modules, Control Logic Module, and Power Supply Module.
Physical Description
1-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
Interface Modules
LRS-24B Rear Section
User Modules
Control Logic
Module
Power Supply
(PS)
LRS-24 Front Section
Figure 1-4. LRS-24B Enclosure
1-8
Physical Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 1 Introduction
LRS-24F ETSI UNIT
LRS-24F is a modular chassis suitable for installation in standard ETSI racks, having
a height of 300 mm (6U). The chassis has physical slots arranged in two rows:
•
The lower row accepts 4U-high functional modules (the modules that perform
the various processing functions).
•
The top row accepts 2U-high interface modules, which contain the connectors
used to access the modules in the lower row. The interface modules enable
the connection of cables from the front side, and thus functional modules can
be easily removed for maintenance without disconnecting cables.
Figure 1-5 shows a 3-dimensional view of LRS-24F.
Figure 1-5. LRS-24F 3-D View
LRS-24F Enclosure
Figure 1-6 shows the LRS-24F enclosure including User Modules and Interface
Modules, Control Logic module, and Power Supply module.
Physical Description
1-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
Interface Modules
User Modules
CONTROL LOGIC
Module
Power Supply
(PS)
Figure 1-6. LRS-24F Enclosure
LRS-24 Module Slots
The LRS-24F enclosure has a lower section for the functional modules and a top
section for interface modules. The LRS-24B enclosure has a front section for the
functional modules and a rear section for interface modules.
Each section has 15 module slots:
•
•
•
Two slots are reserved for PS modules.
One slot is reserved for the common logic module (CM-1 or CM-2).
The other 12 slots are intended for user (I/O) modules. Each I/O slot can
accept any type of I/O module. The modules are inserted from the front side.
The top section of LRS-24F (back section of LRS-24B) includes slots for the
interface modules.
Front View
Figure 1-7 shows a typical front view of the LRS-24F enclosure, and identifies the
slots and their use. Note the labels that designate the type of module that can be
installed in each slot.
1-10
Physical Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Internal Modules
Chapter 1 Introduction
Internal Modules for
for User Modules
System Slots
LRSI-F-PSP / 230 / 115
LRSI-F1-CM2
LRSI-F2 LRSI-F2 LRSI-F2 LRSI-F2
LRSI-F3
LINE
LRSI-F-PSP / 48
LRSI-F3
LINE
LRSI-F3
LINE
1
PHANTOM
1
S
T
A
T
I
POWER
PHANTOM
150V
150V
LINE
LINE
LINE
LINE
2
2
O
N
C
L
K
DCE
DCE
DCE
DCE-1
DCE
DCE-1
48V
10BT
DCE-2
DCE-2
CHASS
GND
100-230 VAC
3A T 250V
I/O 8
I/O 1
CL
I/O12
I/O10
I/O 9
I/O 6
I/O 4
I/O 3
I/O 2
PS-B
PS-A
I/O11
I/O 7
I/O 5
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
TD1 TD2
RD1 RD2
POWER
TD2
POWER
TD
RD
TD
RD
TD
RD
TD
RD
TD1
TD
RD
RD1 RD2
RTS2
RTS1
RTS1 RTS2
RTS
DCD
ALARMS
E
ALARMS
E
ALARMS
SIGNAL
RTS
DCD
RTS
DCD
RTS
DCD
STAT / ADD
CONTROL
E
1
DCD1DCD2
SYNC LOSS
DCD1DCD2
SYNC LOSS
1
1
SIGNAL
SIGNAL
LINE
LINE
LINE
SYNC LOSS SYNC LOSS SYNC LOSS
LINE
A
B
A
B
A
B
LOS QLTY
LOS QLTY
LOS QLTY
1
2
QLTY
R
S
1
2
LOS
TEST
TEST
QUALITY
QUALITY
QUALITY
A
B
A
B
A
B
2
3
2
1
2
1
2
LINE
LINE
LINE
TEST ALARM TEST ALARM
TEST ALARM
HTU-T1
TEST ALARM TEST ALARM TEST ALARM
ASMi-450 ASMi-450 ASMi-450
TESTERR
ASMi-50C
ERR2
ERR1
ERR1 ERR2
ASM-40CD
HTU-E1
HTU-E1
CM-2
ASM-40CD
Control
Logic
Module
Power
Supply
Redundant
Power Supply
(Option)
User Modules
System Slots
Figure 1-7. LRS-24F Enclosure, Typical Front View
1.3 Functional Description
The main functions of the LRS-24 chassis are to provide mechanical support and
connections between the various modules.
The main modules are:
•
•
•
Power Supply (PS) Modules
Common Logic Modules
I/O (User) Modules.
Power Supply (PS) Modules
The LRS-24 hub can be powered by AC and DC power supply modules. Two
power supply modules can be installed to provide redundancy. The following
types of AC and DC power supply modules are available for LRS-24:
•
AC power supply module, PS-LRS/230/115 – operates on 100 to 240 VAC
nominal, and provides a maximum total output power of 120W.
Functional Description
1-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
•
DC power supply module, PS-LRS/48 – operates on –48 VDC, and provides a
maximum total power of 120W.
The PS modules are installed in dedicated chassis slots. The chassis has two PS
slots, enabling the installation of two PS modules, for redundancy. When both
modules are operational, they share the load; in case of failure or loss of input
power, the remaining module continues to supply the power alone. Switchover is
thus automatic and does not interrupt normal operation.
A redundant module can be installed in an operating enclosure without turning off
the enclosure power. An AC and a DC PS module can be installed simultaneously.
Several I/O modules installed in the chassis can supply remote (phantom) feed
voltage for the remote equipment connected to the modules installed in the
LRS-24. This voltage must be provided by an external source.
RAD offers a standalone unit, LRS-PS-FEED, that can provide the required voltage
for the remote power source. LRS-PS-FEED is explained in Appendix B of this
manual.
The phantom feed voltage is connected through the power supply interface
module and through the corresponding PS to the internal phantom feed
distribution bus of the LRS-24.
Common Logic Modules
LRS-24 is managed by either of the two CM modules, CM-1 or CM-2. The main
functions of the two module types are:
•
Interfacing between a management facility and the equipment modules
installed in LRS-24. The CM-1 module only supports management by means of
a supervision terminal; the CM-2 module also supports network management
stations.
•
Distribution of an external clock signal (station clock) to the equipment
modules. The station clock interface circuits of the common logic modules
have the following user-selectable modes:
− T1 DSU interface per ANSI TR-62411 and ANSI T1.403, with 100Ω
balanced T1 line interface. This mode accepts an AMI-coded clock signal of
1544 kHz. The maximum signal attenuation is 10 dB.
− E1 DSU interface per ITU-T Rec. G.703, which accepts an
HDB3-coded clock signal of 2048 kHz. The E1 interface can be configured
to operate as a 120Ω balanced line interface, or a 75Ω unbalanced
interface. The maximum line attenuation is 10 dB.
− Square interface per TTL input.
The recovered clock signal is returned toward the equipment providing the clock
signal (remote loop condition, controlled by a user jumper).
1-12
Functional Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 1 Introduction
Management
CM-1 Management Capabilities
An ASCII terminal can be used as a supervision terminal to manage the CM-1
module. The supervision terminal is connected to one of the RS-232 asynchronous
serial supervisory ports (one port is located on the CM-1 module itself and the
second port is located on the interface module serving the CM-1 module).
The CM-1 module operates as an interface module that does not process the
management information, but only transfers the management traffic transparently
to the modules installed in the LRS-24. Therefore, the supervision terminal is
controlled by the software stored in the managed modules, and the management
capabilities depend on the capabilities of the managed modules.
For a description of the management activities supported by a terminal connected
to the CM-1 module, refer to the Installation and Operation Manuals available for
the modules installed in LRS-24.
CM-2 Management Capabilities
The CM-2 module enhances the management capabilities available to the user by
including three different management functions:
•
•
•
SNMP management. For SNMP management, the CM-2 module
communicates via an additional management interface located on the
interface module serving the CM-2 module. Currently, two types of interfaces
are available: an Ethernet 10BaseT interface (for UTP and STP media), and an
Ethernet 10Base2 interface (for coaxial media). This configuration is illustrated
in Figure 1-8.
SNMP management communication with an LRS-24 module that includes
an SNMP agent is handled by an internal SNMP agent and bridge/router
located on the CM-2 module. To enable SNMP management of modules
without SNMP agents, the CM-2 module includes a proxy agent that converts
the management traffic to the proprietary internal protocol used to manage
such modules.
Management by an ASCII terminal operating as a supervision terminal. The
terminal, which is controlled by the software stored in the managed modules,
connects to the serial RS-232 asynchronous supervisory port located on the
CM-2 module (see Figure 1-8). The management capabilities available through
the terminal are similar to those available through the CM-1 module.
•
•
Management by means of Telnet. The CM-2 also supports the Telnet
protocol. This enables remote management via the same command line
interface used with a supervision terminal. Telnet uses TCP/IP communication
through the Ethernet port of the CM-2 card.
Management via RS-232 by Slip Protocol with SNMP management.
Functional Description
1-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
LRS-24
LRS-24
MBE
WAN
Supervision
Terminal
MBE
LRS-24
LRS-24
Management
Station
Figure 1-8. Basic Management Configuration for LRS-24 with CM-2 Modules
I/O (User) Modules
LRS-24 can be equipped with various types of input/output (I/O) modules to
provide the required system functions. These include ASMi-24C, ASMi-31C,
ASMi-31CQ, ASMi-50C, ASMi-450C, HTU-E1C, FOMi-40C, FOMi-E1/T1C,
FOMi-E3C, FOMi-T3C, MTMi-20C, FOMi-40CD, ASM-40CD, FOMi-E1/T1/CD,
ASMi-50CD, and ASMi-51CQ.
The range of modules and options available for LRS-24 is continuously expanding.
Refer to the Installation and Operation Manuals of the corresponding modules for
information.
1.4 Technical Specifications
Number of
Functional Module
Slots
15 – Each slot is connected to an interface module slot
Chassis
Characteristics
Slot Usage
2 power supply slots
1 common logic slot
12 identical slots for I/O (user) modules
100 – 240 VAC nominal, 50/60 Hz, maximum 160W
Module
PS-LRS/230/115
Power
Module PS-LRS/48 –48 VDC nominal, maximum 160W
Remote (Phantom) LRS-PS-FEED standalone unit
Source
1-14
Technical Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 1 Introduction
External Clock Interface
Type
T1
T1 Mode
Clock Rate
Line Interface
Line Code
Receive Level
Transmit Level
Type
1.544 MHz
100Ω, balanced
Bipolar AMI
0 through -10 dB
3V 10%, balanced
E1
E1 Mode
Bit Rate
2.048 MHz
Line Interface
120Ω, balanced
75Ω, unbalanced
Line Code
AMI
Receive Level
Transmit Level
0 through -10 dB
3V 10%, balanced
2.73V 10%, unbalanced
Square
Minimum 2.2V peak-to-peak amplitude
CM-1 Management Interface
Functionality
Transparent interfacing to internal management ports of
I/O modules
Hardware
RS-232 asynchronous port, compatible with
VT-52, VT-100, FREEDOM-100, FREEDOM-110,
FREEDOM-220
Data rates up to 9.6 kbps
Word format: software-configurable
Software
Terminal driven by software stored in each I/O module
CM-2 Management Interface
Functionality
Terminal management interface
SNMP agent with internal bridge/router and ARP server
for internal modules
Protocol conversion between internal management
protocols of I/O modules and external management
function
Technical Specifications
1-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 1 Introduction
LRS-24 Installation and Operation Manual
Hardware
Ethernet 10BaseT interface for UTP and STP media
Ethernet 10Base2 interface for coaxial media
RS-232 asynchronous port, compatible with VT-52,
VT-100, FREEDOM-100, FREEDOM-110, and
FREEDOM-220
Asynchronous Port Data rate: 38.4 kbps
Characteristics
Word format: one start bit, eight data bits, no parity, one
stop bit
Software
SNMP over Ethernet LAN port
Terminal interface controlled by software stored in the
CM-2 module
LRS-24F
Physical Data
Height
299 mm/ 11.8 in
533.8 mm/ 21 in
Width including
brackets
Width without
brackets
437.8 mm/ 17.2 in
252 mm/ 9.9 in
Depth
LRS-24B
Height
177 mm/ 7.0 in
Width including
brackets
533.8 mm/ 21 in
Width without
brackets
437.8 mm/ 17.2 in
324 mm/ 12.8 in
Depth
Operating
Temperature
32°F to 113°F / 0°C to 45°C
0°F to 150°F / –20°C to +70°C
Up to 90%, non-condensing
Environment
Storage
Temperature
Humidity
1-16
Technical Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2
Installation and Setup
This chapter provides installation and operation instructions for the LRS-24 system,
and the basic system configuration of the power supply (PS) and common logic
(CM-1 and CM-2) modules. It includes the following topics:
•
•
•
•
•
•
Site requirements and prerequisites
Equipment needed
Package contents
Installation and setup
Interfaces and connections
Initial operation and basic checks
See Chapter 3 for management via a CM-1 module and Chapter 4 for
management via a CM-2 module.
2.1 Introduction
If LRS-24 includes a CM-2 module, you must configure management parameters
of the CM-2 module before the management functions are operable. This
procedure is explained in Chapter 4.
After installing the basic system, install the user modules according to the system
installation plan, as explained in the Installation and Operation Manual of the
individual modems.
No internal settings, adjustment, maintenance, and repairs may be performed
by either the operator or the user; such activities may be performed only by a
skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
Warning
Mechanical Data
Figure 2-1 provides mechanical data on the LRS-24F chassis. Figure 2-2 provides
mechanical data on the LRS-24B chassis.
Introduction
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
Figure 2-1. LRS-24F Mechanical Diagram
2-2
Introduction
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
LRS-24B FRONT VIEW
WITHOUT MODULES
LRS-24B TOP VIEW
LRS-24B SIDE VIEW
Figure 2-2. LRS-24B Mechanical Diagram
Introduction
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
2.2 Site Requirements and Prerequisites
This section describes how to prepare the site for installation of the LRS-24 hub.
AC Power
DC Power
Install the LRS-24 chassis with AC power supply modules within 1.5m (5 feet) of an
easily accessible, grounded, 100 to 240 VAC outlet.
LRS-24 chassis with DC power supply modules require a –48 VDC power source.
Since no power switch is provided for the DC power supply modules, connect the
DC power to LRS-24 through a circuit breaker located close to LRS-24. This
provides overcurrent protection for the input power line, and enables turning off
power to LRS-24.
Grounding
The LRS-24 case must be properly grounded at all times, both to protect the
user and to prevent possible damage to equipment. It will prevent damage
when a fault condition occurs on the lines connected to the equipment, such
as lightning stroke or contact with high-voltage power lines.
Warning
Never connect cables to an LRS-24 that is not properly grounded. Any
interruption of the protective (grounding) connection inside or outside the
equipment or the disconnection of the protective ground terminal can make
this equipment dangerous. Intentional interruption is prohibited. Before
switching on this equipment and before connecting any other cable, the
protective ground terminal of the enclosure must be connected to a protective
ground.
The LRS-24 enclosures are grounded through the protective (grounding) conductor
of the power cable. In addition, each of the LRS-24 power supply interface
modules has a grounding screw located on its front panel. Connect this screw by a
short, wide copper strap to a reliable, low-resistance grounding system.
Caution
When LRS-24 is installed in racks, the rack itself should also be grounded in
accordance with standard practice and the locally applicable regulations. Installing
LRS-24 in a grounded rack provides additional protection against fault conditions.
Interface Module Handling Precautions
LRS-24 interface modules are grounded by installation in a grounded LRS-24
chassis.
2-4
Site Requirements and Prerequisites
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Caution
For your safety, always disconnect all the cables connected to an LRS-24 interface
module before removing that module from LRS-24. Do not connect cables to an
interface module that is not installed in a grounded LRS-24.
Module Handling Precautions
Caution
The LRS-24 modules contain components sensitive to electrostatic discharge (ESD).
To prevent ESD damage, always hold a module by its sides, and do not touch the
module components or connectors. Before touching a module, we recommend
that you discharge the electrostatic charge of your body by touching the frame of a
grounded equipment unit.
Modules can be installed and removed from LRS-24 while LRS-24 is powered and
operating. However, if LRS-24 is not yet powered, turn off the input power while
inserting a PS module into LRS-24.
Front Clearance
Allow at least 90 cm (36 inches) of frontal clearance for operator access.
Ambient Requirements
The ambient operating temperature of LRS-24 should be 32° to 113°F
(0° to 45°C), at a relative humidity of up to 90%, non-condensing.
Cooling
LRS-24 units are cooled by free air convection. The cooling vents are located in
the top and bottom covers.
Caution Do not obstruct these vents. Allow at least 1U of space below and above the unit.
2.3 Unpacking the Chassis
Before unpacking, make a preliminary inspection of the container. Evidence of
damage should be noted and reported immediately.
➤
To unpack the equipment:
1. Place the container on a flat surface, cut all straps, and open the top of the
container.
2. Carefully take LRS-24 out of the container and place it securely on a flat, clean
surface.
3. Inspect the unit for signs of damage. Report immediately any damage found.
Unpacking the Chassis
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
4. Check the packing list against your order to ensure that the supplied modules
match your order. If modules have been pre-installed in accordance with your
order, check that all modules are in their proper slots and are secure. Report
immediately any deviations.
5. Check that all necessary cables have been included.
2.4 Installation and Setup
This section describes how to perform the mechanical installation of the following
items:
•
•
•
PS module
CM-1 module
CM-2 module.
PS Modules
This section covers the installation of the PS modules in an LRS-24 enclosure. For
installation of the associated PS interface modules, see Section 2.5. Obtain the
system installation plan before starting the installation.
Dangerous voltages are present inside the PS modules when connected to
power.
Do not connect a PS interface module to power before it is properly installed
within the LRS-24 enclosure. Disconnect the input power from the module
before removing it from the enclosure.
Warning
Two types of PS modules are currently available: PS-LRS/230/115, and PS-LRS/48.
Each module is also available with the /P option, which supports the supply of
remote feed voltage from an external source.
Front Panels
Typical front panels for PS modules are shown in Figure 2-3. Indicator functions
are listed in Table 2-1.
2-6
Installation and Setup
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
PS-LRS
48VDC
PS-LRS/230/115
POWER
POWER
+5V
-5V
+5V
-5V
LRS-24
LRS-24
AC Power Supply Module
DC Power Supply Module
Figure 2-3. PS Module Panels
Table 2-1. PS Modules, Front Panel Indicators
Indicator
Function
Status
POWER
At least one of the PS modules installed in LRS-24
is receiving input power and can provide +5V
Lights up (green)
LRS-24 is not receiving power
Off
+5V
–5V
This PS module is providing a normal +5V output
voltage
Green
+5V is not available in LRS-24
Off
This PS module is providing a normal –5V output
voltage
Green
–5V is not available in LRS-24
Off
Fuses
The PS modules include internal fuses that should not be replaced by the user.
In addition, the AC power supply (PS-LRS/230/115) is protected by an external,
user-replaceable fuse located in the AC power connector of the corresponding
interface module, which protects the input line.
Installation and Setup
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
PS Module Installation
➤
To install the first PS module:
1. Make sure that the POWER switches on the two LRSI-PS interface modules are
set to OFF.
2. Insert the specified PS module in the PS-A slot, referring to the system
installation plan in LRS-24 Module Slots, Chapter 1.
3. Fasten the PS module with the two screws.
4. If an additional redundant module is used, install it in the PS-B slot.
Note
You can install a redundant module in an operating enclosure without turning off
the enclosure power. After the module is installed, connect the power cable and set
the power switch located on the corresponding interface module to ON.
An AC and a DC PS module can be installed at the same time.
CM-1 Module
This section covers installation of the CM-1 module and of the associated interface
module in an LRS-24 enclosure. The first part covers the installation of the CM-1
module. The second section covers the installation of the interface module for the
CM-1 module: LRSI-F-CM1.
Front Panel
A typical front panel for the CM-1 module is shown in Figure 2-4. The functions of
the components located on the front panel are listed in Table 2-2.
2-8
Installation and Setup
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
POWER
TD
M
RD
A
N
A
G
E
M
E
N
T
R
S
2
3
2
CM-1
Figure 2-4. Module CM-1 Front Panel
Table 2-2. Module CM-1, Front Panel Components
Item
Function
POWER Indicator
Lights up when the CM-1 module is receiving input power
(+5V)
TD Indicator
Lights up to indicate activity on the transmit (input) line of
the RS-232 MANAGEMENT port
RD Indicator
Lights up to indicate activity on the receive (output) line of
the MANAGEMENT
RS-232 port
MANAGEMENT RS-232 Direct connection of supervision terminal to LRS-24
Connector management port
Installation and Setup
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
Internal Jumpers
Figure 2-5 shows the location of the user-selectable jumpers located on the CM-1
module. Figure 2-3 lists the jumper settings.
The CM-1 module includes additional factory-set jumpers, which must not be
moved by the user.
Jumper JP9, JP10
JP15 RCEN
JP14 STATCLK
TTL Level
Clock at
Balanced
EN
SYS
BAL
System
Levels
Converter
Enabled
Clock
Interface
Unbalanced
Clock
Interface
TTL Level
Converter
Disabled
Clock at
TTL Levels
TTL
UNBAL
DIS
BAL
UBAL
JP4
E1-BAL
T1-DSU
E1-UBAL
JP5
JP6
STATCLK
RCEN
RLOOP LCODE
EN
SYS
AMI
ON
DIS
HDB3
TTL
OFF
Interface Selection
Jumpers JP4, JP5, JP6
JP12 RLOOP
JP11 LCODE
JP4
Remote Loopback
Toward Station
Clock Source
AMI
ON
E1-BAL
T1 Line
Code
JP5
JP6
Balanced
E1 Interface
E1 Line
Code
No Loopback
HDB3
JP4
JP5
JP6
OFF
Balanced
T1 Interface
T1-DSU
JP4
JP5
JP6
Unbalanced
E1 Interface
E1-UBAL
Figure 2-5. Module CM-1, Internal Jumpers
2-10
Installation and Setup
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Table 2-3. Module CM-1 Jumper Settings
Values
Jumpers
Description
JP4, JP5, JP6, Select the station clock interface in the
T1 interface (1544 kHz clock): Set jumper JP5 in
the T1-DSU position and jumpers JP9 and JP10 to
BAL.
JP9, JP10,
STATION CLK connector of the
LRSI-F-CM1 interface module.
Balanced E1 interface (2048 kHz clock): Set
jumper JP4 in the E1-BAL position, and jumpers JP9
and JP10 to BAL.
Unbalanced E1 interface (2048 kHz clock): Set
jumper JP6 in the E1-UBAL position, and jumpers
JP9 and JP10 to UBAL.
Default setting: Balanced E1 interface
LCODE, JP11 Selects the line code accepted by the
station clock interface in the STATION
CLK connector of the LRSI-F-CM1
interface module.
AMI—AMI line code: Use this selection for the T1
interface.
HDB3—HDB3 line code: Use this selection for the
E1 interfaces.
Default setting: HDB3
RLOOP, JP12 Controls the operating mode of the
station clock interface in the STATION
CLK connector of the LRSI-F-CM1
interface module.
ON: The station clock interface returns the
regenerated clock signal toward the clock source.
OFF: The station clock interface does not return
clock signal toward the clock source.
Unless your system has special requirements,
always set the jumper JP12 to ON.
Default setting: JP12 ON
STATCLK,
JP14
Selects the levels of the clock signal
provided by the CM-1 module as a
station clock signal for the user modules
installed in LRS-24.
SYS: Clock signal at G.703 levels regenerated from
the STATION CLK connector.
TTL: Clock signal at TTL levels, provided by a
dedicated line receiver.
Select the position best suited to the requirements
of the user modules installed in LRS-24: for
HTU-E1C module, always set the jumper JP14 to
SYS and the jumper JP15 to DIS.
Default setting: SYS
RCEN, JP15
Connects the supply voltage to the line
receiver which provides a clock signal at position when the jumper JP14 is set to TTL.
EN: Line receiver enabled. Always select this
TTL levels when the jumper JP14 is set
DIS: Line receiver disabled. Always select this
to TTL.
position when the jumper JP14 is set to SYS.
Default setting: DIS
Installation and Setup
2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
CM-1 Installation Procedure
➤
To install CM-1:
Insert the CM-1 module into the CL slot, and fasten it with the two screws.
•
CM-2 Module
This section covers the installation of the CM-2 module in an LRS-24 enclosure.
Front Panel
A typical front panel for the CM-2 module is shown in Figure 2-6. The functions of
the components located on the front panel are listed in Table 2-4.
POWER
Power Indicator
TD
Management Transmit
Activity Indicator
RD
Management Receive
Activity Indicator
STAT/ADD
Status/Address
Display
CONTROL
R
S
2
3
2
CM-2
Figure 2-6. Module CM-2 Front Panel
2-12
Installation and Setup
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Table 2-4. Module CM-2, Front Panel
Function
Indicator
POWER
TD
Lights up when CM-2 is receiving input power (+5V)
Lights up to indicate activity on the transmit (input) line of
the ETHERNET MANAGEMENT port
RD
Lights up to indicate activity on the receive (output) line of
the ETHERNET MANAGEMENT port
STAT/ADD Display
If a failure is detected during the power-up self-test, displays
a code that identifies the failure type
During normal operation, displays the two least significant
digits of the hub number
MANAGEMENT
RS-232 Connector
Direct connection of supervision terminal to LRS-24
management port
Internal Jumpers
Figure 2-7 shows the location of the user-selectable jumpers located on the CM-2
module.
The module includes additional factory-set jumpers, which must not be moved by
the user.
Installation and Setup
2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
Clock Selection
E1 E1 T1
75120100
E1 E1 T1
75120100
E1 E1 T1
75120100
JP2
JP8
JP9
JP3
JP1
JP4
JP5
JP7
JP6
JP2
JP8
JP9
JP3
JP1
JP4
JP5
JP7
JP6
JP2
JP8
JP9
JP3
JP1
JP4
JP5
JP7
JP6
E1 75
E1 120
T1 100
Unbalanced
Balanced
Balanced
BYPASS PASSWORD
JP15
JP16
J1
JP14
SCC1 SCC2
E1 E1 T1
75120100
JP2
JP8
JP9
JP3
JP1
JP4
JP5
JP7
JP6
NC GND
J5
J7
Watchdog JP 14
GND Selection JP 12
Signal GND connected
to Frame GND
ON
N.C. GND
N.C. GND
Signal GND not
connected to Frame GND
OFF
Figure 2-7. Module CM-2, Internal Jumpers
Table 2-5 lists the functions of the jumpers located on the CM-2 module.
2-14
Installation and Setup
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Table 2-5. Module CM-2 Jumper Settings
Jumpers
Description
Factory Settings
JP1 – JP9
Sets the jumpers according to the station clock applied to the STATION CLK
connector of the LRSI-F*-CM2 interface module. The available selections are
T1 clock source (1544 kHz clock), or E1 clock source (2048 kHz clock):
• T1 source: always select the balanced interface
E1 120
• E1 source: select either the balanced or unbalanced interface, in
accordance with the source providing the clock signal
JP12
Selects connection of Signal Ground to Frame Ground:
• GND – Connected
• N.C. – Disconnected
Enables Watchdog:
GND
ON
JP14
JP15
(see Figure 2-7)
Enables Password:
Bypass
• Bypass – Password not required
• Password – Password required
Terminal Select:
JP16
SCC1
• SCC1
• SCC2
* Interface module version, for example, LRSI-F-1, LRSI-F-2, etc.
Figure 2-7 identifies the jumper settings for each clock source interface.
CM-2 Installation
➤
To install CM-2:
1. Check that the POWER switch of the interface module is set to OFF.
2. Insert the CM-2 module in the CL slot.
3. Fasten with the two screws.
2.5 Interfaces and Connections
This section describes the installation and connections for:
•
•
•
•
•
PS Interface Modules
LRSI-F-CM1 Interface Module
LRSI-F-1-CM2 Interface Module
LRSI-F-2-CM2 Interface Module
LRS-24 Enclosure.
Interfaces and Connections
2-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
PS Interface Modules
This section explains the installation of the interface modules for PS modules.
Dangerous voltages are present inside the PS interface modules when
connected to power.
Do not connect a PS interface module to power before it is properly installed
within the LRS-24 enclosure, and disconnect the input power from the module
before removing it from the enclosure.
Warning
Table 2-6 shows the types of PS interface modules that are currently available for
LRS-24.
Table 2-6. PS Interface Module Types
Power Supply
Interface Modules
Description
Module Type
AC PS-LRS/230/114
LRS-PS/230/115
Connection to AC power source
LRSI-PSP/230/115
Connection to AC power source and to an external remote (phantom)
feed power supply, type LRS-PS-FEED. The LRS-PS-FEED is required for
powering remote units, for example, when an HTU-E1L is connected
through an HTU-E1C module, and is intended for use with PS modules
having the IP option.
DC PS-LRS/48
LRSI-PSP/48
Connection to DC power source and to an external remote (phantom)
feed power supply, type LRS-PS-FEED, and is intended for use with
PS modules having the /P option.
Front Panels
Typical front interface panels for PS modules are shown in Figure 2-8:
•
•
•
AC-PS modules (LRSI-PS/230/115)
DC-PS module (LRSI-PS/48)
Typical interface panel with remote feeding connector (LRSI-PSP/230/115).
Each panel includes the following items:
•
Power input connector – For AC modules, the power input connector includes
an integral fuse
•
•
•
For AC modules – power switch
Grounding screw
PHANTOM feed input connector.
Figure 2-8 shows the location of this connector only on the interface panel for
AC modules. The same option is also available on the interface panel for
DC PS modules.
2-16
Interfaces and Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
LRSI-F-PSP/230/115
PHANTOM POWER
150V
LRSI-F-PS/48
PHANTOM
150V
_
_
+
+
CHASS
GND
CHASS
GND
48V
+
_
CHASS
GND
MAIN POWER SUPPLY
100-230VAC
3A T 250V
CAUTION
CAUTION
THIS UNIT MAY HAVE MORE
THAN ONE POWER SUPPLY. TO
REDUCE THE RISK OF ELECTRIC
SHOCK DISCONNECT ALL
POWER SUPPLY CORDS BEFORE
SERVICING
THIS UNIT MAY HAVE MORE
THAN ONE POWER SUPPLY. TO
REDUCE THE RISK OF ELECTRIC
SHOCK DISCONNECT ALL
POWER SUPPLY CORDS BEFORE
SERVICING
Figure 2-8. LRSI-F-PSP/230/114 and LRSI-F-PS/48 Interface Module Panels
Interface Module Installation
➤
To install the PS interface module:
1. Check that the POWER switch of the interface module is set to OFF.
2. Insert the specified type of module in the PS-A interface slot, referring to the
system installation plan, in LRS-24 Module Slots, Chapter 1.
3. Fasten with the two screws.
4. If an additional (redundant) PS module is used, install the corresponding
module in the PS-B interface slot.
LRSI-F-CM1
This section explains the installation of the interface module for the CM-1 module,
LRSI-F-CM1.
Interface Module Front Panel
A typical LRSI-F-CM1 module front panel is shown in Figure 2-9.
Interfaces and Connections
2-17
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
LRSI-F-CM1
S
T
A
T
I
O
N
C
L
K
M
A
N
A
G
E
M
E
N
T
R
S
2
3
2
Figure 2-9. Typical LRSI-F-CM1 Interface Module Panel
The module panel includes two connectors:
•
•
MANAGEMENT RS-232 connector, for connection to a supervision terminal.
STATION CLK, for connection to an external (station) clock source. The station
clock is distributed to all the modules installed in LRS-24.
Interface Module Installation
➤
To install LRSI-F-CM1 Interface module:
1. Check that the POWER switch of the interface module is set to OFF.
2. Insert the LRSI-F-CM-1 module in the CL interface slot.
3. Fasten with the two screws.
LRSI-F-1-CM2 / LRSI-B-1-CM2 Interface Modules with 10BaseT
This section explains the installation of the 10BaseT Interface module for the CM-2
module: LRSI-F-1-CM2 or LRSI-FB-1-CM2.
LRSI-F-1-CM2 10BT / LRSI-B-1-CM2 Front Panel
A typical LRSI-F-1-CM2 or LRSI-B-1-CM2 module front panel, with 10BaseT, is
shown in Figure 2-10.
2-18
Interfaces and Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
LRSI-F-1-CM2
LRSI-B-1-CM2
10BT
ACT
LINK
10BT
ACT
LINK
Figure 2-10. LRSI-F-1-CM2/LRSI-B-1-CM2 Interface Module Panel with 10BT
The module panel includes two connectors:
•
MANAGEMENT 10BT ETHERNET – RJ-45 connector to connect the 10BaseT
management interface of the CM-2 module to the LAN that carries the
management traffic. Two LEDs indicate status of connector (Table 2-7).
•
STATION CLK – to connect to an external (station) clock source. The station
clock is distributed to all the modules installed in LRS-24.
Table 2-7. Management 10BT Ethernet LEDs
LED
LINK
ACT
Color
Link
Indication
Connection is made
Data is passed through connector
Activity
In addition to the clock interface, the connector also includes the major and minor
alarm indication lines (optional, provided by dry relay contacts).
Interfaces and Connections
2-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
LRSI-F-1-CM2 Internal Settings
Figure 2-11 shows the internal settings available on the LRSI-F-1-CM2 module.
The interface module includes additional factory-set jumpers, which must not be
moved by the user.
Connect Minor
Alarm Relay
Connect Major
Alarm Relay
JP9
JP7
JP6
JP10
JP11
JP8
JP7 JP6
JP9 JP8
JP10 JP11
1
2
3
JP1
JP2
JP3
JP4
JP5
Ethernet Connections
1
2
For Connection
To Hubs
(not Crossed)
TX: Pins 1, 2
RX: Pins 3, 6
JP1
JP2
JP3
JP4
JP5
2
3
JP1
JP2
JP3
JP4
JP5
For Connection
To LAN (Crossed)
TX: Pins 3, 6
RX: Pins 1, 2
Figure 2-11. Interface Module LRSI-F-1-CM2 with UTP Connector, Internal Jumpers
Table 2-8 lists the functions of the jumpers located on the LRSI-F-1-CM2 module.
2-20
Interfaces and Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Table 2-8. LRSI-F-1-CM2 Module Jumper Settings
Jumpers
Controls
Settings/Options
JP6, JP7, JP8
Major alarm relay connection
To use the major alarm relay, install jumpers as shown in
Figure 2-11.
To disconnect the relay, remove the jumpers (for storage, you
may leave the jumpers inserted over one pin).
JP9, JP10, JP11
JP1 through JP5
Minor alarm relay connection
To use the minor alarm relay, install jumpers as shown in
Figure 2-11. To disconnect the relay, remove the jumpers.
Connect internal transmit and receive pairs to the external UTP pairs (10BaseT connector) to allow
direct connection (without cross cables) as below:
Jumper Settings
Receive Pair
Transmit Pair
Over pins 1-2
Over pins 2-3
Pins 1,2
Pins 3,6
Pins 3,6
Pins 1,2
The correct selection depends on the wiring conventions used in your particular network,
however.
Normal jumper setting:
• CM-2 module connects directly to the LAN (this interchanges the connections of the receive
and transmit pairs): set the jumpers to position 2-3
• CM-2 module connects to an Ethernet hub: set the jumpers to position 1-2.
LRSI-F-1-CM2 Installation
➤
To install LRSI-F-1-CM2:
1. Check that the POWER switch of the interface module is set to OFF.
2. Insert the LRSI-F-1-CM2 module in the CL interface slot.
3. Fasten it with the two screws.
LRSI-F-2-CM2 Interface Module with 10Base2
This section explains the installation of the 10Base2 Interface module for the CM-2
module, LRSI-F-2-CM2.
LRSI-F-2-CM2 10B2 Front Panel
A typical LRSI-F-2-CM2 module front panel is shown in Figure 2-12.
Interfaces and Connections
2-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
LRSI-F-2-CM2
S
T
A
T
I
O
N
C
L
K
M
E
T
A
N
A
G
E
M
E
N
T
10B2
H
E
R
N
E
T
Figure 2-12. LRSI-F-2-CM2 Interface Module Panel with 10B2
The module panel includes two connectors:
•
MANAGEMENT 10B2 Ethernet connector – a BNC connector for connecting
the 10Base2 management interface of the CM-2 module to the LAN that
carries the management traffic.
•
STATION CLK – for connection to an external (station) clock source. The
station clock is distributed to all the modules installed in LRS-24. In addition to
the clock interface, the connector also includes the major and minor alarm
indication lines (optional, provided by dry relay contacts).
LRSI-F-2-CM2 Internal Settings
Figure 2-13 shows the internal settings available on the LRSI-F-2-CM2 module.
The interface module includes additional factory-set jumpers that must not be
moved by the user.
2-22
Interfaces and Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Connect Minor
Alarm Relay
Connect Major
Alarm Relay
JP9
JP7
JP6
JP10
JP11
JP8
JP7 JP6
JP9 JP8
JP10 JP11
Figure 2-13. Interface Module LRSI-F-2-CM2 with BNC Connectors, Internal Jumpers
Table 2-9 lists the functions of the jumpers located on the LRSI-F-2-CM2 module.
Table 2-9. LRSI-F-2-CM2 Interface Module Jumper Settings
Jumpers
Controls
Settings/Options
JP6, JP7, JP8
Major alarm relay connection
To use the major alarm relay, install
jumpers as shown in Figure 2-11 or
Figure 2-13.
To disconnect the relay, remove the
jumpers (for storage, you may leave
the jumpers inserted over one pin).
JP9, JP10, JP11 Minor alarm relay connection
To use the minor alarm relay, install
jumpers as shown in Figure 2-11 or
Figure 2-13.
To disconnect the relay, remove the
jumpers.
Interfaces and Connections
2-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
LRSI-F-2-CM2 Installation
➤
To install the LRSI-F-2-CM2 module:
1. Insert the LRSI-F-2-CM2 module in the CL interface slot.
2. Fasten with the two screws.
LRS-24 Enclosure
This section describes the mechanical installation for the LRS-24B/LRS-24F
enclosure and the various connections to it.
Mechanical Installation
LRS-24 is intended for installation in 300 mm and 600 mm ETSI racks. Before
installing the enclosure, check whether the required modules are in place, in
accordance with the installation plan.
The enclosure is fastened to the rack by four screws (two on each side).
Caution
Do not connect any cables to the enclosure before it is installed in the designated
position.
Ground Connection
Connect a thick copper wire or braid between each grounding screw located on a
power supply interface module and the designated grounding point of LRS-24.
Cable Connections
Before applying power to LRS-24 and before connecting any cable, the
protective ground terminals of this equipment must be connected to a
protective ground system.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting the protective ground terminal can make this
equipment dangerous. Intentional interruption is prohibited.
Make sure that only fuses of the required rating, are used for replacement. The
use of repaired fuses and the short-circuiting of fuse holders is forbidden.
Whenever it is likely that the protection offered by fuses has been impaired,
the equipment must be made inoperative and be secured against any
unintended operation.
Warning
Power Connection
LRS-24 accepts two PS modules. When two PS modules are installed, either
module can provide the power to LRS-24. The modules installed in LRS-24 start
operating when one of the PS modules is powered up.
2-24
Interfaces and Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
AC Power Connection
➤
To connect LRS-24 to AC power:
1. Check that the switch on the PS is set to OFF.
2. Use the 5-ft. (1.5m) standard power cable terminated by a standard 3-prong
plug to connect AC power to the LRS-24.
3. Connect the power cable to the connector on the panel of LRSI-PSP/230/115
interface module.
4. Connect to the mains outlet.
5. Turn the POWER switch to ON to initiate the LRS-24.
DC Power Connection
➤
To connect LRS-24 to DC power:
1. Connect the power cable between the DC distribution panel and the
DC power connector of the LRSI-PSP/48 interface module.
2. Check that you have correct polarity.
Note
DC power supply interface modules do not have power switches. Therefore, the
DC power supply will start operating when DC power is applied.
To avoid turning on LRS-24 when connecting the power cables, use an external
circuit breaker located near LRS-24 to control the supply of DC power, and
protect the DC input line. Set the circuit breaker to OFF before connecting the
DC power cable to LRS-24.
Note
When redundant power supplies are used, it is recommended to connect the
power cables to outlets powered by different circuits.
Connection of External Phantom Feed Voltage
An external power supply unit is necessary to supply external feed voltages.
HTU-E1C/P, etc. require phantom feed voltage.
The recommended source for external voltages is LRS-PS-FEED, offered by RAD.
LRS-PS-FEED is a standalone unit, intended for rack mounting (refer to
Appendix B). To minimize cable runs, install LRS-PS-FEED directly above LRS-24
(leave 1U free space between LRS-24 and the LRS-PS-FEED). In this situation,
connect the output cable of the LRS-PS-FEED (supplied with the LRS-PS-FEED
unit) to the PHANTOM connector of the LRSI-PSP/48 or LRSI-PSP/230/115
interface module.
Interfaces and Connections
2-25
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
Note
The external feed voltage passes through the interface module and through the
corresponding PS module to the internal bus. Therefore, you can ensure constant
external feed voltage (in case one of two installed power supply modules is
removed) by connecting LRS-PS-FEED to both modules.
It is recommended that you turn on the external voltage source only after LRS-24
is turned on.
Station Clock Connections
➤
To connect an external (station) clock signal to LRS-24:
1. Connect the clock source to the STATION CLK connector located on the
interface module serving the CM-1 or CM-2 module, using a Shielded Cable.
2. Select the required clock.
Note
When configured to External, but no External Clock is connected, Internal Clock is
applied.
Dry Contact Alarm Connections
The CM-2 module enables the connection of major and minor alarm relay
contacts to a bay alarm system. Connect the bay alarm cable to the STATION CLK
connector located on the interface module serving the CM-2 module. Table 2-10
lists the STATION CLK connections.
Table 2-10. CM-2 Module STATION CLK Connector, Pin Allocation
Pins
Function/Connection
STATION CLK In
STATION CLK Out
Major Alarm
3, 11
1, 9
7, 8, 15
6, 13, 14
2, 4, 5, 10, 12,
Minor Alarm
N. C.
Management Connections
Refer to the installation plan to determine the cable intended for connection to the
enclosure. Management connections depend on the type of module installed in
LRS-24.
CM-1 Module
Connect the supervisory cable to the MANAGEMENT RS-232 connector on the
LRSI-F-CM1 interface module.
CM-2 Module
Connect the management cable to the MANAGEMENT Ethernet connector
(an RJ-45 connector on the LRSI-F-1-CM2 interface module and a BNC connector
on the LRSI-F-2-CM2 interface module).
2-26
Interfaces and Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Table 2-11 lists the supervisory cable pin arrangement.
Table 2-11. CM-1 Module Management RS-232 Pin Allocation
Pin
2
Function/Connection
Transmit data
3
Receive data
7
Signal ground
2 and 3
4 and 6
2, 3
1, 6
Crossed
Crossed
Transmit or receive data
Receive or transmit data
Connection to I/O (User) Modules
Refer to the Installation and Operation Manual of the corresponding module.
2.6 Initial Operation and Basic Checks
This section describes the operation instructions and basic checks for the following
configurations:
•
•
LRS-24 with CM-1 Module
LRS-24 with CM-2 Module.
LRS-24 with CM-1 Module
Power On
➤
➤
To turn on LRS-24 (CM-1):
1. Set the ON/OFF switches on the panels of the LRSI-PSP** modules to ON.
2. Supply the DC power, if applicable.
To supply external phantom feed voltages:
1. Turn on LRS-24.
2. Turn on the source, i.e. LRS-PS-FEED.
Normal Indications
•
PS Module(s): All the indicators on the panel(s) of the PS module(s) turn green
to indicate proper operation.
•
CM-1 Module: The POWER indicator of the module lights up. The TD and
RD indicators flash (or light steadily) when a management session is in
progress.
Initial Operation and Basic Checks
2-27
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
•
I/O Module(s): Refer to the Installation and Operation Manual of the I/O
modules.
If LRS-24 does not show normal indications, see Chapter 5, Troubleshooting and
Diagnostics.
Power Off
➤
To turn off LRS-24 (CM-1):
1. If an external phantom feed voltage source is connected to LRS-24, turn off
that source (for example, the LRS-PS-FEED).
2. Set the ON/OFF switch(es) of the PS module(s) to OFF.
3. Disconnect the DC power, if applicable.
Troubleshooting
If a malfunction occurs in one or more of the links served by a module installed in
LRS-24, perform the following preliminary checks:
•
If the problem affects all the links:
− Check that all the indicators on the panels of the PS modules are green.
− If any indicator is red, replace the corresponding PS module.
Check that all the modules are properly installed.
•
•
Check that all the cable connections are made in accordance with the
installation plan.
•
•
Check that all the communication equipment on the link is operating properly.
Check for proper configuration of the local and remote equipment.
If these checks do not correct the problem, use a supervision terminal connected
to the MANAGEMENT RS-232 port of the CM-1 module to identify the fault and
replace the corresponding module, see Chapter 5, Troubleshooting and
Diagnostics.
LRS-24 with CM-2 Module
Power On
➤
➤
To turn on LRS-24 (CM-2):
1. Set the ON/OFF switches on the panels of the LRSI-PSP** modules to ON.
2. Supply the DC power, if applicable.
To supply external phantom feed voltages:
1. Turn on LRS-24.
2. Turn on the source, i.e. LRS-PS-FEED.
2-28
Initial Operation and Basic Checks
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 2 Installation and Setup
Normal Indications
•
PS Module(s): All the indicators on the panel(s) of the PS module(s) must turn
green to indicate proper operation.
•
CM-2 Module: The POWER indicator of the module must light up. The TD
and RD indicators may flash (or light steadily) when a management session is
in progress.
•
•
On start-up, Mask says IGNORE ALARM FROM REMOTE MANAGEMENT.
The default is MASK ON. You must change configuration to MASK OFF.
Normally, the STAT/ADD display shows the two least significant digits of the
management number assigned to LRS-24. For normal startup, a rotating red
circle is displayed. However, if a problem is detected during the power-up
self-test, you will see a flashing error code (E1 through E9), see Chapter 5
Troubleshooting and Diagnostics.
•
I/O Module(s): Refer to the Installation and Operation Manual of the
corresponding module.
Power Off
➤
To turn off LRS-24 with CM-2:
1. If an external phantom feed voltage source is connected to LRS-24, turn off
that source (i.e. LRS-PS-FEED).
2. Set the ON/OFF switch(es) of the PS module(s) to OFF.
3. Disconnect the DC power, if applicable.
Troubleshooting
In case a malfunction occurs, perform the following preliminary checks:
•
If the problem affects all the links:
− Check that all the indicators on the panels of the PS modules are green.
− If any indicator is red, replace the corresponding PS module.
Check that all the modules are installed properly.
•
•
Check that all the cable connections are made in accordance with the
installation plan.
•
•
Check that all the communication equipment on the link is operating properly.
If the error code E5 appears on the STAT/ADD display of the CM-2 module,
reconfigure the management parameters of the module in accordance with
Chapter 4. Any other code indicates a technical problem, and the
CM-2 module must be replaced.
•
•
Check for proper configuration of the local and remote equipment.
See Mask section (Defining Card Configuration / Defining I/O Module
Operational Parameters).
Initial Operation and Basic Checks
2-29
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 2 Installation and Setup
LRS-24 Installation and Operation Manual
If these checks do not correct the problem, identify the fault and replace the
corresponding module using the management station connected to the
management Ethernet port, or a supervision terminal connected to the
management RS-232 port of the CM-2 module.
2-30
Initial Operation and Basic Checks
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 3
Management via the CM-1
Module
This chapter provides information on the management of LRS-24 enclosures
equipped with CM-1 control logic modules. It includes:
•
•
•
General description of CM-1 functions and their integration in the system
Supervision terminal hardware requirements
Methods to connect supervision terminal or network management station to
LRS-24
•
Starting a management session by means of the supervision terminal.
For information regarding the management of LRS-24 enclosures equipped with
CM-2 control logic module, refer to Chapter 4.
3.1 Introduction
CM-1 Functions
The functions of the CM-1 module are limited to physical interfacing between a
supervision terminal and the equipment modules installed in the LRS-24. No
processing takes place in the CM-1 module. The supervision terminal can be
connected to one of the RS-232 management ports either directly, or through a
low-speed modem link.
The RS-232 management ports of the CM-1 module are connected through a
digital sharing circuit to each of the internal control ports of the equipment
modules. Thus, only one of the modules, the module selected by the user, can
interact with the terminal at any time. Therefore, it is not possible to
simultaneously monitor the operation of the whole LRS-24.
The user specifies the desired module by adding a node number before any
command. The node number is the number of the LRS-24 slot in which the
desired module is installed, 1 through 12. The module specified evaluates the
command, executes it, and sends a response to the terminal, i.e. NODE 10.
Management Capabilities
The transfer of management traffic by the CM-1 module, to the modules installed
in the LRS-24 is transparent. Therefore, only modules that include software for
controlling a supervision terminal, for example, ASMi-450C, HTU-E1C, etc., can
be managed through the CM-1 module.
Introduction
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 3 Management via the CM-1 Module
LRS-24 Installation and Operation Manual
3.2 Hardware Requirements
Terminal Characteristics
You can use most types of standard ASCII terminals in order to manage the
modules installed in an LRS-24, via a CM-1 module. The terminal, which can be a
“dumb” terminal or a personal computer emulating an ASCII terminal, requires an
RS-232 communication interface.
The terminal types supported by the modules that can be installed in the LRS-24
are VT-52, VT-100, TV-920, FREEDOM-100, FREEDOM-110, FREEDOM-220, or
other terminals that are fully compatible with one of these terminals.
The software used to operate the supervision program is contained in the managed
modules. Refer to the Installation and Operation Manual of the relevant modules
for detailed terminal operating instructions.
The managed modules store all the configuration information generated or altered
during the communication with the terminal: no information is stored in the
terminal.
Modules must be initialized properly to ensure correct terminal operation as
explained in Section 3.3; otherwise some of the commands may not work
properly.
Management RS-232 Port Interface Characteristics
The CM-1 module has an RS-232 asynchronous DCE port designated
Management RS-232. This port has a 9-pin D-type female connector, which
enables direct connection to terminals. Since terminals usually have DTE
interfaces, their connection is made by means of a straight-through cable. For
connection to a modem, use a cross cable (also called a null modem cable). For
detailed instructions on connecting terminals, see below.
The control lines and their directions appear in Appendix A.
After establishing communication with a module, you can select the data rate and
the word format (number of data bits, parity type, and number of stop bits). This
information is provided in the Installation and Operation Manuals of the modules
installed in the LRS-24.
For initial operation, it is recommended to start with the default parameters:
Default data rate: 38.4 kbps
Default word format: one start bit, eight data bits, odd parity, one stop bit.
Connecting the Terminal
A supervision terminal can be connected either directly to the supervisory port, or
through a modem or any other type of full-duplex data link. The CM-1 module
supports only dial-in; it cannot dial out.
3-2
Hardware Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 3 Management via the CM-1 Module
This section presents typical methods for the connection of a supervision terminal
to the CM-1 module installed in the LRS-24 unit.
Direct Connection of Supervision Terminal
Figure 3-1 shows typical connections of a terminal. Both types of connections
(direct connection to the MANAGEMENT RS-232 port located on the
CM-1 module, or to the corresponding connector on the LRSI-F-CM1 module
serving the CM-1 module) are shown. Note that the cable used to connect to the
terminal is a straight-through cable.
LRS-24
Management
RS-232
Supervision
Terminal
Figure 3-1. Typical Direct Connection of Supervision Terminal
Connection through Modem Link
Figure 3-2 shows a typical connection through a modem link (or other type of
low-speed data link). Note that the cable used to connect to the terminal is a
cross cable.
Hardware Requirements
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 3 Management via the CM-1 Module
LRS-24 Installation and Operation Manual
LRS-24
Management
RS-232
Modem
Telephone
Network
Modem
Supervision
Terminal
Figure 3-2. Typical Connection of Supervision Terminal Through Modem Link
3.3 Operating the CM-1 Supervision Terminal
General
This section provides general procedures for using a supervision terminal to
perform the preliminary configuration and to manage the individual CM-1
modules installed in LRS-24.
Before starting, make sure you are familiar with the configuration parameters and
management procedures of each module type installed in LRS-24, as described in
Installation and Operation Manuals for each module. The procedures given in this
section supplement the procedures appearing in these manuals.
To reconfigure or troubleshoot modules already configured, obtain the current
communication parameters and passwords from the system manager before
starting.
Configuring the Terminal
➤
To configure the terminal for communication parameters used by the module:
1. Select the full-duplex mode.
2. Turn off the terminal echo.
3. The recommended communication parameters are the default parameters:
9600 bps, 1 start bit, 8 data bits, odd parity, 1 stop bit, no flow control.
3-4
Operating the CM-1 Supervision Terminal
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 3 Management via the CM-1 Module
4. Connect the communication cable of the supervision terminal to either the
management RS-232 connector on the LRSI-F-CM1 module (serving the CM-1
module), or to the connector with the same name located on the CM-1
module (refer to Section 3-2 for details).
5. Make sure LRS-24 is powered. Turn on the supervision terminal. When
applicable, also turn on the modems and any other communication
equipment used to connect the terminal to LRS-24.
You are now ready to start the configuration session.
Note
For instructions on how to select default communication parameters, default
terminal type and default password, refer to the Installation and Operation Manuals
for the various modules.
Performing Preliminary Configuration
Perform the following activities on each module that is to be managed by means of
the supervision terminal:
➤
To configure each module:
1. Define the terminal type you are using by entering the command
NODE nn, followed by the command used to define the terminal type for the
desired module, i.e., DEF TERM.
2. To change the communication parameters after establishing communication:
Use the command NODE nn DEF SP.
3. To change the current password: Use the command NODE nn DEF PWD.
Note
In the following sections, nn represents the number of the slot in which the desired
module is installed.
Configuring Individual Modules
After completing the preliminary configuration, start the configuration of the
individual I/O modules. Before each command, add the prefix NODE nn.
Operating the CM-1 Supervision Terminal
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 3 Management via the CM-1 Module
LRS-24 Installation and Operation Manual
3-6
Operating the CM-1 Supervision Terminal
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 4
Management via the CM-2
Module
The information presented in this chapter includes:
•
•
CM-2 functions
Description of supervision terminal hardware requirements, and of methods
for connecting a supervision terminal or network management station to
LRS-24
•
•
Supervision terminal commands
Supervision terminal operating instructions.
The instructions appearing in this chapter assume that the supervision terminal
operator is familiar with the configuration parameters of the modules installed in
LRS-24.
4.1 Introduction
This chapter describes how to use a supervision terminal to manage an LRS-24
enclosure that contains a CM-2 control logic module.
The CM-2 module also enables management of the LRS-24 system by means of a
RADview network management station, or other SNMP-based network
management station. For information regarding the use of the RADview network
management station, refer to the RADview User's Reference Manual.
CM-2 Module Capabilities
The CM-2 module includes an internal SNMP agent, and therefore it requires
preliminary configuration. The preliminary configuration of LRS-24 must always be
performed using a standard ASCII terminal connected to the CM-2 front panel
supervisory port, designated MANAGEMENT RS-232. You can use terminals of the
following types: VT-52, VT-100, TV-920, FREEDOM-100, FREEDOM-110,
FREEDOM-220, or other terminals that are fully compatible with one of these
terminals.
Introduction
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
After performing the preliminary configuration, you can also manage the modules
installed in LRS-24 (equipped with the CM-2 module) using the following options:
•
Manage all the modules installed in LRS-24 (including modules without
internal SNMP agents) by means of SNMP-based network management
stations. This is accomplished by connecting the station to the Ethernet port
located on the interface module serving the CM-2 module, LRSI-F1-CM2 or
LRSI-F2-CM2 through RS-232 using the SLIP Protocol. For example, you can
use the RADview network management station offered by RAD.
•
•
Use the terminal as a supervision terminal under control of the software
installed in the CM-2 module, or in modules with supervision-terminal support
software.
Manage via TELNET (terminal emulation).
Notes
1. If a key is not pressed for 10-15 minutes a message appears informing you that
you are disconnected from LRS-24. You must reconnect your terminal to
LRS-24.
2. Only one user can connect to LRS-24 at a time. If a second user tries to connect
to LRS-24 a message appears (see Chapter 5).
3. If Password Enable = YES and you do not press a key for 20 minutes a message
appears informing you that “You’re disconnected”. Press any key and the Password
Screen appears.
CM-2 Functions
CM-2 includes an advanced management module that enables using SNMP-based
network management stations to fully manage the equipment installed in LRS-24,
and monitor its status.
CM-2 performs the following functions:
•
Identification of cards – automatically identifies the modules installed in the
LRS-24 hub and determines the internal management protocols supported by
each card. Basically, two types of protocols are used, one for managing
modules with internal SNMP agent, and another for managing modules
without agent.
•
Initialization – automatically initializes the management parameters for each
module installed in LRS-24. This feature provides plug-and-play capabilities,
because the management system can always make contact and manage any
new module installed in LRS-24.
•
•
Traps – remote connection involves an update in the management station’s
screen in order to receive Traps.
Interface – provides the interface to SNMP-based network management
stations, and the interface required for using an ASCII terminal connected to
the CM-2 module as a supervision terminal.
4-2
Introduction
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
•
Identification of Failures – automatically identifies failure of the management
communication, and enables alternate management modes, in accordance
with the following priorities:
− Network management stations
− Supervision terminal
− For a module without internal SNMP agent–allows remote configuration in
accordance with the parameters of the remote module connected in a link
with the LRS-24 module.
When communication with a management function with higher priority is
restored, the management capabilities are automatically returned to it.
•
•
Routing – routes the management traffic received through the various ports to
its intended destination (module), and processes the messages received from
the modules for transmission through the appropriate management port.
Format – automatically translates the format of the incoming and outgoing
messages to the internal management protocols used by various modules.
Moreover, when simultaneous access is attempted, the CM-2 module
arbitrates handling management requests according to a built-in system of
priorities.
•
•
Manages Hub Functions – manages the general hub functions
(for example, power supplies).
Data Storage – stores LRS-24 configuration data in non-volatile memory.
Handling of Management Communication
The services provided by the CM-2 module depend on the type of management
communication (ASCII terminal, network management station, or remote module)
and the type of modules (with or without internal SNMP agent) which are
addressed by the external management function.
Internal handling of the SNMP management communication is as follows:
•
Modules with Internal SNMP Agent – the internal protocol is SNMP over
SLIP. (However such modules also include management software for directly
operating an ASCII terminal).
Routing of SNMP messages is made in accordance with IP addresses assigned
to the various modules by the CM-2 module, which provides their initialization
parameters.
Refer to Appendix C for additional information.
Terminal messages are routed directly to the addressed module. After the
addressed module starts communicating with the terminal, it takes control and
the terminal then operates under direct control of that module.
•
Modules without Internal SNMP Agent – a proprietary protocol is used for
internal management communication. SNMP messages are accepted through
the dedicated management (Ethernet) interface, are converted to the
proprietary protocol, and routed to the slot with the desired module. The
CM-2 module serves as a proxy agent for these modules.
Introduction
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
The CM-2 module also includes the functions required to handle the exchange of
management communication with a supervision terminal connected to the serial
port of the CM-2 module. The supervision terminal addresses a specific module by
specifying its node number. The node number is actually the number of the
LRS-24 physical slot in which the module is installed (1 through 12 for user
I/O modules, 13 for the CM-2 module itself).
For each message, the CM-2 module uses its terminal interfacing functions to read
the node number, and then processes the message according to the capabilities of
the addressed module.
The processing is as follows: a proprietary protocol is used for the internal
communication. Therefore, the CM-2 module uses its terminal interfacing function
to convert any message to the proprietary protocol, and route it to the addressed
module. This conversion also ensures that the user always sees a consistent
interface.
When a link to a remote module connected to a module installed in LRS-24 is set
up, the CM-2 module also enables the management function to access the remote
module. The available remote management capabilities depend on module
characteristics (see the relevant module Installation and Operation Manual).
Management Priorities
The CM-2 module is designed to give the highest priority to SNMP-based
management. Therefore, when the CM-2 module is connected to an SNMP-based
management station through the dedicated management interface, the serial
supervisory port cannot be used for management unless the network management
station operator specifically transfers the management to the supervisory port. The
serial port can, however, be used at any time for reading the module configuration
and status.
The supervisory port is also automatically enabled in case the management station
is not active, however, when the station becomes active it automatically takes
control and disables management through the serial port.
If neither the network management station nor the terminal is active, the CM-2
module can also read configuration parameters from the remote module in a link
with a local module.
Preliminary Configuration Activities
The CM-2 module, as well as other modules installed in LRS-24, requires
preliminary configuration. Preliminary configuration is performed using an ASCII
terminal connected to the CM-2 serial supervisory port. The serial port
characteristics are as follows:
Default data rate: 38.4 kbps
Default word format: 1 start bit, 8 data bits, no parity, 1 stop bit
4-4
Introduction
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
Preliminary Configuration of CM-2 module
•
Configuration of the terminal type supported by its supervisory port.
•
Configuration of its SNMP agent parameters. This function is needed to
establish communication with SNMP-based management stations, and to
designate the management stations authorized to manage LRS-24.
The configuration activities are a prerequisite for performing other activities. They
must be performed whenever a new CM-2 module is installed in an LRS-24
system.
Preliminary Configuration of Other Modules.
•
Preliminary configuration required by I/O modules is described in their
Installation and Operation Manuals. A complete set of preliminary
configuration activities, which are actually required only for modules with
internal SNMP agent, must also include configuration of I/O module
supervisory port.
•
Remote connection involves an update in the management station’s screen in
order to receive Traps.
Initializing CM-2
The management module of the CM-2 module is designed for plug-and-play
support. As explained above, this includes automatic identification of the modules
installed in LRS-24, the management protocols that can be used for each module,
the preliminary configuration data, and other relevant information.
These activities are performed automatically, without any user intervention:
•
•
•
Upon power-up
Upon inserting or removing a module
Upon moving a module to a new position in the enclosure.
These capabilities are essential to enable the replacement of modules while
LRS-24 is powered, without disrupting the operation of the equipment. In
addition, the CM-2 module includes provisions to ensure that the service provided
by the links supported by the modules installed in LRS-24 is not disrupted when
the module is temporarily removed, or even when the CM-2 module is completely
replaced. However, when the CM-2 module is removed, it is not possible to
perform monitoring and configuration activities.
The functions performed during initialization are adapted to the management
requirements of each type of module.
Modules with Internal SNMP Agent
The CM-2 module does not store parameters for modules with an internal SNMP
agent because they store their configuration data locally. However, the CM-2
module must detect the presence of these modules (whether present upon
power-up or inserted later), and transfer the configuration parameters needed for
starting the management communication.
Introduction
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
Modules without Internal Agent
The CM-2 module will store configuration data locally for modules where such
data is provided by an external management function. Therefore, special
arrangements are needed to enable the provision of the configuration parameters
for each individual module:
•
Power-up – upon power-up, the goal is to restore the last operational
configuration automatically and reliably. For this purpose, the CM-2 module
analyzes the configuration parameters stored in the local module, in the
remote module connected in a link with the local module, and also its own
configuration data associated with the module:
− If the parameters in the local and remote equipment are identical and
valid (valid means that all the parameters are consistent and within the
allowed ranges), these parameters are automatically copied to the CM-2
data base, and used as the operational parameters.
− If the parameters of the local and remote modules differ, or invalid
parameters are detected in at least one of them, but valid parameters are
stored in the CM-2 data base, these parameters are automatically
downloaded to the equipment and used to determine the operational
configuration after power-up.
− If the CM-2 module has been powered off, its configuration data is no
longer considered valid. In this case the operator is prompted to
reconfigure the equipment parameters.
•
•
Replacement of CM-2 module – the procedure explained above is also used
if a CM-2 module is plugged into an operating system.
Replacement of local module or remote equipment – the appropriate
parameters are automatically downloaded from the CM-2 database. If the
CM-2 database is not valid, the operator must determine the desired
configuration.
4.2 Hardware Requirements
Terminal Characteristics
Any standard ASCII terminal (“dumb” terminal or personal computer emulating an
ASCII terminal) equipped with an RS-232 communication interface can be used to
perform the preliminary configuration and manage an LRS-24 equipped with the
CM-2 module.
The software used to operate the supervision program is contained in the CM-2
module. Moreover, the CM-2 module stores all the configuration information
generated or altered during the communication with the terminal: no information
is stored in the terminal.
4-6
Hardware Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
Modules must be initialized properly to ensure correct terminal operation, as
explained in Section 4.4; otherwise, some of the commands may not work
properly.
RS-232 Supervisory Port Interface Characteristics
The CM-2 module has an RS-232 asynchronous DCE port, designated
Management RS-232. This port has a 9-pin D-type female connector, which
enables direct connection to terminals. Since terminals usually have DTE
interfaces, their connection is made by means of a straight-through cable. For
connection to a modem, use a cross cable (also called a null modem cable). For
detailed instructions on connecting terminals, see below.
The control lines that are used, and directions for connections are listed in
Appendix A.
The data transfer characteristics are as follows.
Default data rate: 38.4 kbps
Default word format: 1 start bit, 8 data bits, no parity, 1 stop bit
Terminal Connection Methods
This section presents typical methods for the connection of a supervision terminal
to the CM-2 module installed in the LRS-24 unit.
Connection of Supervision Terminal
A supervision terminal can be connected either directly to the supervisory port, or
through a modem or any other type of full-duplex data link. The CM-2 module
supports unrestricted dial-in and only major alarms in dial-out.
Figure 4-1, Figure 4-2, and Figure 4-3 show typical connections. Note that the
cable used to connect directly to the terminal is a straight-through cable, whereas
the connection to the modem requires a cross-cable.
Connection of Management Station
The Network Management Station connection is made through the Ethernet
interface, available in the Management Ethernet connector of the CM-2 interface
module (this is a 10BaseT interface for the LRSI-F1-CM2 module and a 10Base2
interface for the LRSI-F2-CM2 module).
Figure 4-4 shows a typical connection in which a network management station
with 10BaseT Ethernet interface is connected through a hub to several LRS-24
units installed in a rack.
Figure 4-1 shows a typical configuration without hub. In this case, the Management
Ethernet connectors of the LRS-24 units connect directly to the Ethernet media.
For convenience, the 10BaseT interface in the LRSI-F1-CM2 module can be
adapted by means of internal jumpers (Installation and Setup in Chapter 2) to
enable connection by means of straight cables, either to a hub or directly to the
LAN media.
Hardware Requirements
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
LRS-24
Management
RS-232
Supervision
Terminal
Figure 4-1. Typical Direct Connection of Supervision Terminal
LRS-24
Management
RS-232
Modem
Telephone
Network
Modem
Supervision
Terminal
Figure 4-2. Typical Connection of Supervision Terminal Through Modem Link
4-8
Hardware Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
LRS-24
Management
RS-232
Slip
Supervisory
Management
Terminal
Figure 4-3. Typical Connection of Supervision Terminal Through Slip
Hardware Requirements
4-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
Ethernet Hub
Management
Ethernet
Connector of LRS-24
Ethernet
Interface
Management
Station
Figure 4-4. Typical Connection to Network Management Station
4-10
Hardware Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
4.3 CM-2 Supervision Terminal Language
General
This section presents the syntax, usage, and an index of the commands available to
a supervision terminal controlled by the software in the CM-2 module.
For a complete description of each command, see Appendix D.
Similar procedures are available when the terminal is controlled by one of the I/O
modules installed in LRS-24; for detailed instructions, refer to the Installation and
Operation Manuals of the I/O modules.
Command Language Syntax
Prompt
Commands can be entered only when a prompt is displayed. The prompt
always appears at the beginning of a new line, and the cursor appears to
the right of the prompt. The prompt identifies the module controlling the
terminal.
The prompt displayed when the software in the CM-2 module controls
the terminal is CM2>.
When the software controls the terminal in one of the I/O modules that can
directly control it, the prompt is supplied by that module.
Case
Commands are case-insensitive, for example, you can type commands in
either lower case and/or upper case letters, and they will be interpreted as
upper case only. The exception is SNMP community strings, which are
case-sensitive.
Node ID
Commands addressed to a specific module must identify the module
using the node number. By default, the node number is identical to the
chassis slot number. For example, prefixing the command with NODE 7
identifies a module installed in slot 7; commands for the CM-2 module
are identified by the prefix NODE 13.
Corrections
To correct typing errors, press <Back space> until the error is cleared,
and then type the correct characters.
<Enter>
Help
Commands must end with a carriage return <Enter>.
To obtain help, type NODE 13 HLP.
Command Protocol
Duplex Communication after a working prompt is displayed, every character typed on the
terminal keyboard is immediately evaluated by the module that sent the
prompt, and then echoed to the terminal screen. Full duplex
communication with the terminal is therefore necessary to provide on-line
feedback to the terminal operator, and terminal echo must be turned off.
Cursor
When a screen has several fields, use the TAB key to move the cursor
among the various fields. However, for fields with textual entries, press
the <Enter> key to end the entry and move the cursor to the next field.
(This is indicated in the command description).
CM-2 Supervision Terminal Language
4-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
Scrolling Values When a field has a limited range of values, the available values are
displayed by scrolling. To scroll, bring the cursor to the desired field, and
then press <F> or <U> to scroll forward, press <B> or <D> to scroll
backward. Press <+> or <–> to scroll to the next or previous
command, for up to 10 commands.
Command evaluation Starts only when the <Enter> key is pressed.
Errors
In general, if an error is detected during command evaluation, the
command is not executed. Instead, the module will send an error message
to the terminal. The correct command must then be sent again.
Execution
The command is executed only after it is validated.
Index of Commands
Table 4-1 lists the set of commands recognized by the CM-2 module in
alphabetical order.
In addition to the commands listed in Table 4-1, the CM-2 module will recognize
commands addressed to I/O modules that can control directly the supervision
terminal. For information on the commands available for any particular I/O
module, refer to the Installation and Operation Manuals of that module.
Table 4-1. Terminal Command Set Index for CM-2 Module
Command
DEF CALL
DEF CRD
DEF DWL
DEF HUB
DEF MNG
DEF OPR
Function/Action
Defines parameters for the dial-up modem.
Defines modem type per slot and connection to remote site
Defines operational parameters or command for Download Software version
Defines parameters of CM-2 SNMP agent and general LRS-24 parameters
Defines list of management stations receiving traps generated by CM-2 module
Defines general management parameters of an I/O module (applicable only to modules which do not
support direct management by terminal or SNMP)
DEF PRM
Defines basic operational parameters of an I/O module (applicable only to modules which do not support
direct management by terminal or SNMP)
DEF TRM
DEF TST
Defines supervision terminal type
Performs test on an I/O module (applicable only to modules which do not support direct management by
terminal or SNMP)
DSP ALM
DSP ALT
Displays general alarm status of LRS-24
Displays module alarm status (applicable only to modules which do not support direct management by
terminal or SNMP)
DSP HUB
DEF CFG
DEF MDL
DSP LOG
Displays modules installed in LRS-24
Displays Auto Config screen
Downloads to the modem
Displays list of alarms for CM-2 module, or for a selected I/O module (applicable only to modules which
do not support direct management by terminal or SNMP)
DSP STT
Displays I/O module status and diagnostics (applicable only to modules which do not support direct
management by terminal or SNMP)
4-12
CM-2 Supervision Terminal Language
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
Table 4-2. Terminal Command Set Index for CM-2 Module (Cont.)
Command
Function/Action
DSP VER
Displays modem versions
Defines reset
DEF RST
DEF PWD
HLP
Define password
Displays list of commands supported by CM-2 module
4.4 Supervision Terminal Operating Instructions
General
This section provides procedures for using a supervision terminal to perform the
following activities:
•
•
•
Preliminary configuration of the CM-2 module
Preliminary configuration of I/O modules with internal SNMP agent
Management of individual modules.
Before starting, make sure you are familiar with the configuration parameters and
management procedures of the CM-2 module, and of each module type installed
in LRS-24.
The procedures given in this section assume that no management station is actively
managing LRS-24. However, the same procedures also apply when the
management station relinquishes control to the supervision terminal.
Refer to the section Transferring Control to the Supervision Terminal below for an
explanation of the procedures used to transfer control from the management
station to the supervision terminal.
Configuring the Terminal
➤
To configure terminal for communication parameters used by the CM-2
Management RS-232 port:
1. Select the full-duplex mode and turn off the terminal echo.
The required communication parameters are 38.4 kbps, 1 start bit,
eight data bits, no parity, 1 stop bit, and no flow control.
2. Connect the supervision cable of the terminal to the MANAGEMENT RS-232
connector of the CM-2 module (refer to Section 4-2 for details).
3. Make sure LRS-24 is powered-up, and then turn on the supervision terminal.
When applicable, also turn on the modems and any other communication
equipment used to connect the terminal to LRS-24.
4. Start the configuration session.
5. Enter password.
Supervision Terminal Operating Instructions
4-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
Changing the Password
The factory set password is radlrs.
➤ To change the password:
1. Type NODE 13 DEF PWD <Enter>.
The Password Menu Screen appears (see Figure 4-5).
PASSWORD MENU
Enter new password
Enable password
: radlrs
: NO
Figure 4-5. Password Menu Screen
2. Type the new password (up to 27 characters, for terminal and TELNET).
3. If you forget the password, switch JP15 on CM-2 to BYPASS.
BYPASS PASSWORD
JP15
Figure 4-6. JP15 Settings
Preliminary Configuration
➤ To perform preliminary configuration:
1. Press the <Enter> key several times to see the working prompt of LRS-24,
which is by default CM2>.
2. Define the terminal type you are using by entering the command
NODE 13 DEF TRM.
3. Use the command NODE 13 DEF HUB to define the parameters of the CM-2
module, and the general parameters of LRS-24 that you are configuring.
4. Use the command NODE 13 DEF MNG to define the management stations to
which to send traps generated by the CM-2 module.
5. Define the modem cards by entering NODE 13 DEF CRD to define the modules
installed in the LRS-24 hub.
Refer to Chapter 4 for detailed command syntax and protocol.
Configuring Individual Modules
After completing the preliminary configuration, begin configuration of the
individual I/O modules. Before starting this activity, it is recommended to use the
NODE 13 DSP HUB command to identify the modules installed in LRS-24, since
configuration procedures depend on the module management type (IMOD or
SMOD), and model.
4-14
Supervision Terminal Operating Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 4 Management via the CM-2 Module
➤
To configure an SMOD-type module on the DSP HUB data form:
1. Follow the procedures described in the Installation and Operation Manual of
the appropriate module.
2. Pay special attention to the configuration of the parameters of the internal
SNMP agent of the module and its supervisory port parameters.
3. Before each command, type the node number in the format:
Node nn command <Enter>
nn stands for the node number of the desired module, with values
1 through 12, and command is the desired command string.
The prompt changes from CM2> to the module prompt.
Note
If the prompt changes to PASSWORD>, this indicates that password protection is
enabled on the addressed module. Enter the current password to proceed. If the
password is not known, refer to the module Installation and Operation Manual for
instructions.
➤
To configure an IMOD-type module on the DSP HUB data form:
1. Refer to the module Installation and Operation Manual.
2. Enter the following sequence of commands:
NODE nn DEF TST – to ensure no test is active.
NODE nn DEF OPR – to verify that you are in master mode.
NODE nn DEF PRM – to configure the appropriate parameters.
nn stands for the node number of the desired module, with values
1 through 12.
During this procedure, the prompt displayed by the terminal remains CM2>.
Configuration by SNMP Network Management Stations
After preliminary configuration, by means of the terminal, the network
management station manages LRS-24. The basic preliminary parameters cannot be
modified.
Transferring Control to the Supervision Terminal
When a network management station actively communicates with LRS-24, the
supervision terminal can only be used to read status and configuration information.
It cannot modify parameters.
Three minutes after communication between a network management station and
the CM-2 module fails, the CM-2 module automatically changes its operation
mode to management by terminal. When communication is restored, the CM-2
module automatically resumes being controlled by the network management
station.
Supervision Terminal Operating Instructions
4-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
If it is necessary to manage LRS-24 by means of a terminal, the operator of the
network management station can transfer the control. For generic SNMP
management stations, use the MIB browser function to change the parameter
private.radWan.modmSys.modmSystem.modmHub.modmHubParam.
modmHubController
to the value corresponding to terminal management.
For CM-2 management commands, see Appendix D.
Note
This method of transferring control to the supervision terminal is valid only for
SMOD modems.
The remote connection involves an update in the management station screen in
order to receive traps.
4-16
Supervision Terminal Operating Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Chapter 5
Troubleshooting and
Diagnostics
This chapter describes alarms, diagnostic tests and troubleshooting for the LRS-24
system.
5.1 Alarms
Audible and visual indicators provide status of alarms and tests at the network,
card and port level, and include all links connected to the hub. Alarms are
automatically logged and presented upon request, unless otherwise masked.
For more information about alarms, refer to the following sections in Appendix D:
•
•
•
Displaying General Alarm Status
Displaying I/O Module Alarm Status
Displaying Alarms Log.
5.2 Diagnostic Tests
Refer to the diagnostics tests in the Installation and Operation Manual of the
individual module.
5.3 Troubleshooting
The front panel displays indicators E1, E2, E3, E4 and E5 that show the current
state of the LRS-24 (see Figure 5-1). The states are detailed in Table 5-1.
Troubleshooting
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 5 Troubleshooting and Diagnostics
LRS-24 Installation and Operation Manual
Status/Address
Display
E1
Figure 5-1. Error Indicators
Table 5-1. Front Panel Indicator Displays
Indicator
Status
E1
E2
E3
E4
E5
No LAN communication
5.4 Error Messages
LRS-24 displays Error Messages that can be used or troubleshooting (see
Table 5-2).
5-2 Error Messages
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Chapter 5 Troubleshooting and Diagnostics
Table 5-2. Error Messages
Message
Interpretation
**** No Key hit activity. Closing TELNET
No key activity for 10 – 15 minutes
Connection! ****
Sorry TELNET is being used by another
user, try again later!!!
More than one user is trying to connect to
LRS-24 via TELNET
Not authorized user, closing connection to Password is enabled.Five unsuccessful
agent.
attempts have been made to enter
password; TELNET is closed
Enter password: <pressing ‘enter’ will
enter the LRS>
Password is not enabled, press <Enter>
to begin sesssion.
**** No Key hit activity. Closing
TERMINAL Connection! ****
No key activity for 20 minutes.To begin a
session, press any key and the password
message appears.
Error Messages
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Chapter 5 Troubleshooting and Diagnostics
LRS-24 Installation and Operation Manual
5-4 Error Messages
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix A
Connector Wiring
This appendix provides connector information on:
•
•
•
CM-1 module
CM-2 module
PS modules.
For information about the connectors located on the I/O (user) modules, and the
corresponding interface modules, refer to the corresponding Installation and
Operation Manual.
A.1 Station Clock Interface – LRSI-F-CM1 Module
The station clock interface located on the LRSI-F-CM1 module terminates in a
9-pin D-type female connector, designated STATION CLK, and wired in
accordance with Table A-1.
Table A-1. Pin Allocation for STATION CLK Connector
Pin
1
Function
Frame Ground
2, 3
4
Not Connected
Receive Clock Input (tip)
Receive Clock Input (ring)
Transmit Clock Output (tip)
Not Connected
5
6
7
8
Transmit Clock Output (ring)
Not Connected
9
Station Clock Interface – LRSI-F-CM1 Module
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix A Connector Wiring
LRS-24 Installation and Operation Manual
A.2 Management RS-232 Port Interface—LRSI-F-CM1
Module
The Management RS-232 port on the LRSI-F-CM1 module has an RS-232 interface
terminating in a 9-pin female connector wired in accordance with
Table A-2.
Table A-2. Pin Allocation for MANAGEMENT RS-232 Connector
Pin
1
Function
Direction
Output
Output
Input
Data Carrier Detect (DCD)
Receive Data (RXD)
Transmit Data (TXD)
Data Terminal Ready (DTR)
Signal Ground (SIG)
Data Set Ready (DSR)
Request to Send (RTS)
Clear to Send (CTS)
Ring Indicator (RI)
2
3
4
Input
5
N/A
6
Output
Input
7
8
Output
Output
9
A.3 Management RS-232 Port Interface—CM-1/CM-2
Modules
The Management RS-232 port on the CM-1 and CM-2 modules has an RS-232
interface terminating in a 9-pin female connector wired in accordance with
Table A-3.
Table A-3. Pin Allocation for Management RS-232 Connector
on CM-1/CM-2 Modules
Pin
1
Function
Direction
Data Carrier Detect (DCD)
Receive Data (RXD)
Transmit Data (TXD)
Data Terminal Ready (DTR)
Signal Ground (SIG)
Data Set Ready (DSR)
Connected to pins 7, 8
2
Output
3
Input
4
Input, connected directly to pin 6
N/A
5
6
Output, connected directly to pin 4
A-2
Management RS-232 Port Interface—CM-1/CM-2 Modules
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix A Connector Wiring
Table A-3. Pin Allocation for Management RS-232 Connector on
CM-1/CM-2 Modules (Cont.)
Pin
7
Function
Direction
Request to Send (RTS)
Clear to Send (CTS)
Ring Indicator (RI)
Connected to pins 1, 8
Connected to pins 1, 7
N/A
8
9
A.4 Station CLK Connector – LRSI-F-CM2 Modules
The station clock interface located on the LRSI-F-CM2 modules are terminated in
a 15-pin D-type female connector, designated STATION CLK, and wired in
accordance with Table A-4.
The connector also includes the contacts of the major and minor alarm relays.
Table A-4. Pin Allocation for LRSI-F-CM2 Modules, Station Clk Connector
Pin
1
Function
Station Clock Transmit Output (tip)
Not Connected
2
3
Station Clock Receive Input (tip)
Not Connected
4, 5
6
Minor Alarm Relay – Normally Closed (NC) to pin 14
Major Alarm Relay – Normally Open (NO) relative to pin 8
Major Alarm Relay – Common Contact
Station Clock Transmit Output (ring)
Not Connected
7
8
9
10
11
12
13
14
15
Station Clock Receive Input (ring)
Not Connected
Minor Alarm Relay – Normally Open (NO) relative to pin 14
Minor Alarm Relay – Common Contact
Major Alarm Relay – Normally Closed (NC) to pin 8
Station CLK Connector – LRSI-F-CM2 Modules
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix A Connector Wiring
LRS-24 Installation and Operation Manual
A.5 Ethernet Interface Connector – LRSI-F1-CM2 Module
The 10BaseT Ethernet interface located on the LRSI-F1-CM2 module is terminated in
an RJ-45 connector, designated Management Ethernet 10BT, and wired in accordance
with Table A-5. Note that the wiring depends on the settings of the jumpers on the
LRSI-F1-CM2 module, as explained in Section 2-5.
Table A-5. LRSI-F1-CM Module, Ethernet Interface Connector
Pin
Function
Jumpers JP1 - JP5 on Pins 2-3
Jumpers JP1 - JP5 on Pins 1-2
Input: Receive Data wire +
Input: Receive Data wire –
Output: Transmit Data wire –
Not connected
1
2
3
4
5
6
Output:Transmit Data wire +
Output: Transmit Data wire –
Input: Receive Data wire –
Not connected
Not connected
Not connected
Output: Transmit Data wire +
Input: Receive Data wire +
Not connected
7, 8 Not connected
A.6 Ethernet Interface Connector – LRSI-F2-CM2 Module
The 10Base2 Ethernet interface located on the LRSI-F2-CM2 module is terminated
in a BNC connector designated Management Ethernet 10B2.
A.7 Power Connectors
The AC-powered PS modules have one standard IEC three-pin socket with integral
fuse, for the connection of the AC power.
The DC-powered PS modules have one three-pin circular connector, for the
connection of the –48 VDC input voltage. Connector wiring is listed in Table A-6.
Table A-6. DC Power Connector, Pin Functions
Pin
1
Function
Ground
2
Not connected
–48 VDC
3
A-4
Power Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix B
LRS-PS-FEED Power Supply
B.1 Functional Description
LRS-PS-FEED is a standalone power supply unit designed to serve as a source of
remote (phantom) feed power.
LRS-PS-FEED is intended for use in conjunction with modules equipped with a
remote power feeding interface, e.g., HTU-E1C/P, installed in the 24-Card
HDSL/Modem Hub with SNMP Management, LRS-24. The remote power feeding
interface of such modules enables the supply of feed voltage to the remote
equipment connected to the module through standard twisted-pair lines. Each
interface can provide up to 60 mA per output line.
LRS-PS-FEED has one output, terminated in a short cable with a five-pin connector
that can be directly connected to the Phantom Feed connector on the
LRSI-PSP/230/115 or LRSI-PSP/48 interface module.
LRS-PS-FEED is available in two versions:
•
•
AC-powered version that can operates on 115 VAC or 230 VAC
DC-powered version that operates on –48 VDC.
LRS-PS-FEED is intended for installation in 300 mm and 600 mm ETSI racks, as
well as in ANSI and 19" racks. Unit height is 1U.
When used with LRS-24, the LRS-PS-FEED should be installed above LRS-24.
Note
B.2 LRS-PS-FEED Panels
AC-Powered Unit
Figure B-1 shows the front panel of the AC-powered LRS-PS-FEED unit. The front
panel includes a power switch, a Power indicator that lights when the unit is
powered, and a standard 3-pin IEC AC input power socket with integral fuse.
The output voltage (Phantom Out) is provided by means of a short cable
terminated in a five-pin connector.
LRS-PS-FEED Panels
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix B LRS-PS-FEED Power Supply
LRS-24 Installation and Operation Manual
Figure B-1. AC-Powered LRS-PS-FEED Front Panel
Figure B-2 shows the rear panel of the LRS-PS-FEED unit, which includes POWER
indicator that lights when the unit is powered (ANSI option).
Figure B-2. LRS-PS-FEED Rear Panel
DC-Powered Unit
Figure B-3 shows the front panel of the DC-powered LRS-PS-FEED unit. The front
panel includes a POWER indicator, a DC input power connector, and a fuse.
Figure B-3. DC-Powered LRS-PS-FEED Front Panel
The output voltage (PHANTOM OUT) is provided by means of a short cable
terminated in a five-pin connector.
The rear panel of the DC-powered LRS-PS-FEED unit is similar to that of the
AC-powered unit (see Figure B-2).
B.3 Site Requirements
AC Power
Install AC-powered LRS-PS-FEED units within 1.5m (5 feet) of an easily accessible
grounded AC outlet capable of furnishing the required supply voltage, 115 VAC or
230 VAC.
B-2
Site Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix B LRS-PS-FEED Power Supply
DC Power
DC-powered LRS-PS-FEED units require a –48 VDC power source.
Note
No power switch is provided for the DC power supply modules, and therefore it is
recommended to connect the DC power to the LRS-PS-FEED through a circuit
breaker located close to the LRS-PS-FEED, that will also permit turning off the power
to the LRS-PS-FEED.
Grounding
For your protection and to prevent possible damage to equipment when a fault
condition (e.g., lightning stroke or contact with high-voltage power line) occurs
on the lines connected to the equipment, the LRS-PS-FEED case must be
Warning properly grounded at all times. Never connect cables to an LRS-PS-FEED that is
not properly grounded.
Any interruption of the protective (grounding) connection inside or outside the
equipment, or the disconnection of the protective ground terminal makes this
equipment dangerous. Intentional interruption is prohibited.
Before switching on this equipment and before connecting any other cable,
connect the protective ground terminal of the enclosure to a protective
ground.
LRS-PS-FEED units are grounded through the protective (grounding) conductor
of the power cable.
When LRS-PS-FEED is installed in racks, the rack itself should also be
grounded in accordance with standard practice and the locally applicable
regulations. Installing the unit in a grounded rack provides additional
protection against fault conditions.
Front Clearance
Allow at least 90 cm (36 inches) of frontal clearance for operator access.
Ambient Requirements
The ambient operating temperature of the LRS-PS-FEED should be 32° to 113°F
(0° to 45° C), at a relative humidity of up to 90%, non-condensing.
Cooling
LRS-PS-FEED units are cooled by free air convection. The cooling vents are located
in the top and bottom covers. Do not obstruct these vents. Allow at least 1U of
space below and above the unit.
Site Requirements
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix B LRS-PS-FEED Power Supply
LRS-24 Installation and Operation Manual
B.4 Installation and Operation
Preparation for Installation
LRS-PS-FEED can be installed in ETSI racks with front-side access for cable
connection, as well as in ANSI racks, which require rear access. The adaptation is
made by installing the brackets supplied with the unit in the position
corresponding to the desired installation position.
Figure B-4 shows how to install the brackets for front-panel access. Figure B-5
shows bracket installation for rear-panel access.
For installation above the LRS-24, install the brackets as shown in Figure B-4.
Figure B-4. Installation of Brackets for Front Panel Access
Figure B-5. Installation of Brackets for Rear Panel Access
B-4
Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix B LRS-PS-FEED Power Supply
Rack Installation
Position the LRS-PS-FEED unit above LRS-24, leaving at least 1U free space, and
fasten the unit with four screws to the rack side rails.
Power Connection
Note that only the AC-powered LRS-PS-FEED has a POWER (On/Off) switch; the
DC-powered unit does not have a power switch, and therefore it will start
operating when DC power is applied.
➤
To avoid turning on LRS-PS-FEED when connecting the power cables:
1. Before connecting LRS-PS-FEED to AC power, set the On/Off switch on the
LRS-PS-FEED panel to Off.
2. Use an external circuit breaker located near LRS-PS-FEED to control the supply of
DC power, and protect the DC input line. Set circuit breaker to Off before
connecting the DC power cable to the LRS-PS-FEED.
AC Power Connection
Supply AC power to LRS-PS-FEED through the 5 feet (1.5m) standard power cable
terminated by a standard 3-prong plug.
Connect the power cable first to the connector on the panel of the LRS-PS-FEED,
and then to the mains outlet.
DC Power Connection
Connect the power cable between the DC distribution panel and the
DC power connector of the LRS-PS-FEED. Pay attention to correct polarity.
Phantom Voltage Connection
Connect the connector of the Phantom Out cable of the LRS-PS-FEED to the
designated Phantom Feed connector of the LRSI-PSP* interface module installed
in the LRS-24.
Note
* Interface module version, for example, LRS-PSPF1, LRS-PSPF2, etc.
Operation
➤
To operate LRS-24 with LRS-PS-FEED:
1. Turn on LRS-24 before powering up LRS-PS-FEED.
2. After LRS-24 is operating, apply power to LRS-PS-FEED. The Power indicators
of the LRS-PS-FEED light up.
3. When turning off the system, first turn off LRS-PS-FEED; then turn off LRS-24.
Installation and Operation
B-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix B LRS-PS-FEED Power Supply
LRS-24 Installation and Operation Manual
B-6
Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix C
SNMP Management
C.1 Scope
This appendix:
•
Provides specific information required to manage LRS-24 (equipped with the
CM-2 module) via a Simple Network Management Protocol (SNMP)
•
Includes information regarding the operation of the CM-2 SNMP agent.
C.2 SNMP Environment
General
The SNMP management functions of LRS-24 are provided by an internal SNMP
agent, located on the CM-2 module.
The SNMP management communication uses the User Datagram Protocol (UDP),
which is a connectionless-mode transport protocol, part of the suite of protocols of
the Internet Protocol (IP). This section covers the information related to the SNMP
environment. For a description of the IP environment, refer to Section C-3.
SNMP Principles
The SNMP management protocol is an asynchronous command/response polling
protocol: all management traffic is initiated by the SNMP-based network
management station (except for trap messages), which addresses the managed
entities in its management domain. Only the addressed managed entity answers
the polling of the management station.
The managed entities include a function called “SNMP agent”, which is
responsible for interpretation and handling of the management station requests to
the managed entity, and the generation of properly-formatted responses to the
management station.
SNMP Operations
The SNMP protocol includes four types of operations:
GetRequest
Command for retrieving specific management information from the
managed entity. The managed entity responds with a getResponse
message.
SNMP Environment
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix C SNMP Management
LRS-24 Installation and Operation Manual
GetNextRequest Command for retrieving sequentially specific management information
from the managed entity. The managed entity responds with a
getResponse message.
SetRequest
Command for manipulating specific management information within the
managed entity. The managed entity responds with a setResponse
message.
Trap
Management message carrying unsolicited information on extraordinary
events, e.g., alarms, reported by the managed entity.
The Management Information Base
The Management Information Base (MIB) includes a collection of managed
objects. A managed object is defined as a parameter that can be managed, such as
a performance statistics value.
MIB includes the definitions of relevant managed objects. Various MIBs can be
defined for various management purposes, types of equipment, etc.
An object's definition includes the range of values and the “access” rights:
Read-only
Read-write
Write-only
Object value can be read, but cannot be set
Object value can be read or set
Object value can be set, but cannot be read
Not accessible Object value can be neither read nor set
MIB Structure
MIB has an inverted tree-like structure, with each definition of a managed object
forming one leaf, located at the end of a branch of that tree. A unique path
reaches each leaf in the MIB. Therefore, by numbering the branching points from
the top, each leaf can be uniquely defined by a sequence of numbers. The formal
description of the managed objects and the MIB structure is provided in a special
standardized format, called Abstract Syntax Notation 1 (ASN.1).
Since the general collection of MIBs can also be organized in a similar structure,
under the supervision of the Internet Activities Board (IAB), any parameter
included in a MIB that is recognized by the IAB is uniquely defined.
To provide the flexibility necessary in a global structure, MIBs are classified in
various classes (branches), one of them being the experimental branch, and
another the group of private (enterprise-specific) branches. Under the private
enterprise-specific branch of MIBs, each enterprise (manufacturer) can be assigned
a number, which is its enterprise number. The assigned number designates the top
of an enterprise-specific sub-tree of non-standard MIBs. Within this context, RAD
has been assigned the enterprise number 164. Therefore, enterprise MIBs
published by RAD can be found under 1.3.6.1.4.1.164.
MIBs of general interest are published by the IAB in the form of a
Request for Comment (RFC) document. In addition, MIBs are also often assigned
informal names that reflect their primary purpose. Enterprise-specific MIBs are
published and distributed by their originator, which is responsible for their contents.
C-2
SNMP Environment
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix C SNMP Management
MIBs Supported by the LRS-24 SNMP Agent
The interpretation of the relevant MIBs is a function of the SNMP agent of each
managed entity. CM-2 SNMP agent supports the standard MIB-II (RFC 1158).
In addition, LRS-24 SNMP agent supports the RAD-private (enterprise-specific)
MIB identified as (read the following as a continuous string):
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).rad(164).radWan(6).
TBD
Enterprise-specific MIBs supported by RAD equipment, including the LRS-24, are
available in ASN.1 format from the RAD Technical Support Department.
Management Domains Under SNMP
In principle, SNMP enables each management station that knows the MIBs,
supported by a device, to perform all the management operations available on that
device. However, this is not desirable in practical situations, so it is necessary to
provide a means to delimit management domains.
SNMP Communities
To enable the delimitation of management domains, SNMP uses “communities”.
Each community is identified by a name, which is a case-sensitive alphanumeric
string defined by the user (LRS-24 SNMP agents support community names of up
to 20 characters).
Any SNMP entity (this term includes both managed entities and management
stations) can be assigned by its user community names.
Access Restriction Using SNMP Communities
In general, SNMP agents support two types of access rights:
Read-only
SNMP agent accepts and processes only SNMP getRequest and
getNextRequest commands from management stations that have the
same read-only community name.
Read-write
SNMP agent accepts and processes all the SNMP commands received
from a management station with the same read-write community name.
For each SNMP entity it is possible to define a list of the communities which are
authorized to communicate with it, and the access rights associated with each
community (this is the SNMP community name table of the entity). For example,
the SNMP community name table of the SNMP agent of LRS-24 can include three
community names.
In accordance with the SNMP protocol, the SNMP community of the originating
entity is sent in each message. When an SNMP message is received by the
addressed entity, it first checks the originator's community first. If the community
name of the message originator differs from the community name specified for that
type of message in the SNMP community names table of the recipient, the
message is discarded (SNMP agents of managed entities usually report this event
by means of an authentication failure trap).
SNMP Environment
C-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix C SNMP Management
LRS-24 Installation and Operation Manual
CM-2 Communities
The SNMP agent of the CM-2 can use and recognize the following community
types:
Read-only
Read-write
Trap
SNMP community that has read-only authorization, i.e., the SNMP agent
will accept only getRequest and getNextRequest commands from
management stations using that community.
The default read-only community for RAD network management stations
is Public.
SNMP community that has read-write authorization, i.e., the SNMP agent
will also accept setRequest commands from management stations using
that community.
The default write community for RAD network management stations is
Public.
SNMP community to which the SNMP agent will send traps.
The default trap community for RAD network management stations is
Public.
C.3 IP Environment
General
The SNMP agent of the CM-2 can use its dedicated interface, located on its
interface module (LRSI-F1-CM2 or LRSI-F2-CM2), or the serial supervisory port on
the CM-2 module.
In addition, the SNMP agent also handles some of the messages received from a
supervision terminal, as explained in Chapters 1-3.
This section describes the IP environment, and the functions performed by the
SNMP agent.
IP Environment
This section describes the IP environment, and the considerations related to the
assignment of IP addresses.
IP Address Structure
Under the IP protocol, each IP network element (SNMP agents, network
management stations, etc.) is called an IP host and must be assigned an IP address.
This is also true for the Serial Port IP protocol (SLIP). The main difference with
respect to the handling of messages is that to route an IP message to its destination
it is also necessary to provide a MAC address, whereas for SLIP messages this is
irrelevant, because the messages must reach a specific serial port.
An IP address is a 32-bit number, usually represented as four 8-bit bytes. Each byte
represents a decimal number in the range of 0 through 255.
The address is given in decimal format, with the bytes separated by decimal points,
i.e., 164.90.70.47. This format is called dotted quad notation.
C-4
IP Environment
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix C SNMP Management
An IP address is logically divided into two main portions:
•
Network Portion– assigned by the Internet Assigned Numbers Authority
(IANA). There are five IP address classes: A, B, C, D, and E. However, only the
classes A, B and C are used for IP addressing. Consult your network manager
with respect to the class of IP addresses used on your network.
The network portion of an IP address can be one, two or three bytes long, in
accordance with the IP address class. This arrangement is illustrated below:
IP ADDRESS
Byte 1
Byte 2
Byte 3
Byte 4
Class A Network Portion Host Portion
Class B Network Portion
Host Portion
Class C Network Portion
Host Portion
Figure C-1 IP Address
The class of each IP address can be determined from its leftmost byte, in
accordance with the chart in Table C-1.
Table C-1. IP Address Class
Address Class
Class A
First Byte
Address Range
0 thru 127
0.H.H.H through 127.H.H.H
128.N.H.H through 191.N.H.H
192.N.N.H through 223.N.N.H
Class B
128 thru 191
192 thru 223
Class C
N
H
Bytes that are part of the network portion
Bytes that are part of the host portion
•
Host Portion–used to identify an individual host connected to the network.
The host identifier is assigned by the using organization, in accordance with its
specific needs.
Note
The all-zero host identifier is always interpreted as a network identifier, and must
not be assigned to an actual host.
Often the host portion is further subdivided into two portions:
Subnet number Used to identify departmental subnetworks. The subnet number follows
the network identifier.
Host number Last bits of the IP address.
IP Environment
C-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix C SNMP Management
LRS-24 Installation and Operation Manual
Net and Subnet Masks
Net and subnet masks are used to help filter the relevant traffic more efficiently:
the function of the net and subnet mask is to specify how many of the IP address
bits are actually used for the net identifier and for the subnet number.
The mask is a 32-bit word that includes ones in the positions used for net and
subnet identifications, followed by zeros up to the end of the IP address.
Therefore, a subnet mask can be specified by its length (the number of ones).
Assignment of Addresses
The CM-2 module and the I/O modules installed in the LRS-24 must be assigned
consecutive IP addresses: the first (lowest) address must be assigned to the CM-2
module, and the following 12 IP addresses must be reserved for the I/O modules
(the first address is associated with I/O slot 1, and the last address with slot 12).
Unused addresses must be skipped: that is, when an I/O module with internal
SNMP agent is configured, it must be assigned the IP address corresponding to the
slot in which it is installed, even if previous addresses are not assigned.
Default Gateway
When the CM-2 module and the network management station are both
connected to the same IP network, the network identifier part of the CM-2 IP
address must be identical to the network identifier part of the management station
IP address.
However, the CM-2 module and the management station can also be on different
IP networks, and therefore each one will be assigned IP addresses according to its
IP network. In this case, it is necessary to define a default gateway (IP router) for
the CM-2 module, to handle the transfer of management traffic between the CM-2
and the management station.
Handling of Management Communication
The handling of the management communication within the CM-2 module
depends on the type of management communication (ASCII terminal, SLIP, or
UDP/IP) and the type of modules (with or without internal SNMP agent) which are
addressed by the external management function.
Modules with Internal SNMP Agent
This section describes the handling of the SNMP management communication
when this communication is related to modules with internal SNMP agents.
For such modules, the management communication is internally transferred using
SNMP over SLIP. The SNMP management communication is handled as follows:
•
SNMP messages over UDP/IP (the protocol used when a network management
station is connected through the dedicated management interface on the
Ethernet interface modules) are converted to the SLIP protocol.
•
SNMP messages over SLIP (the protocol used when a network management
station is connected through the serial supervisory port of the CM-2 module),
are routed to the addressed module.
C-6
IP Environment
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix C SNMP Management
Routing of IP Management Traffic
The routing of SNMP messages is made in accordance with the IP addresses
assigned to the various modules (the CM-2 module also has its own IP address).
IP addresses are assigned during the preliminary configuration activities. The CM-2
module automatically learns the IP addresses of all the existing I/O modules,
without any user intervention. For this purpose, updates are automatically
performed upon power-up, whenever a module is inserted or moved to a new
position in the enclosure, and also when a new CM-2 module is installed.
Using this information, the CM-2 module can operate as a bridge/router and ARP
(address resolution protocol) server with respect to the modules with SNMP agents
installed in the LRS-24:
•
The first time that a management station which is authorized to manage the
LRS-24 needs to send a message to one of the modules installed in it, it does
not know the MAC address to be used; therefore it issues an ARP request with
the IP address of the desired module. The CM-2 module of LRS-24 containing
the module with the desired IP address answers the message, and includes the
MAC address of the Ethernet interface located on its interface module
(LRSI-F1-CM2 or LRSI-F2-CM2).
The next time, the CM-2 module routes the management message to the
appropriate module in accordance with the IP address included in the
message.
•
A similar procedure is used when an I/O module needs to send a message to a
management station. In this case, the module sends a SLIP message with the
desired IP address, and the CM-2 module converts the SLIP message to a
regular message, by adding the MAC information for the addressed
management station.
If the CM-2 module does not yet know the MAC address, it temporarily
queues the message, and then sends an ARP request to learn that address.
After receiving the answer, the original message is sent.
C.4 SNMP Traps
The SNMP agent of LRS-24 supports the MIB-II authentication trap, and in
addition generates enterprise-specific traps for each alarm message, and for errors
detected as a result of the sanity check performed by modules after changes in
configuration.
SNMP Traps
C-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix C SNMP Management
LRS-24 Installation and Operation Manual
C-8
SNMP Traps
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D
CM-2 Management
Commands
This appendix describes the set of commands recognized by the CM-2 module.
It explains how to define:
•
•
•
•
•
•
•
•
•
•
•
•
•
Dial-up Modem Parameters
LRS-24 and CM-2 SNMP Agent Parameters
Management Stations
CM-2 Download Parameters
Modem Version
I/O Module Management Parameters
Card Configuration
I/O Module Operational Parameters
Supervision Terminal Type
I/O Module Diagnostics
Auto-Configuration
Password
CM-2 Reset.
It explains how to display:
•
•
•
•
•
General Alarm Status
System Status
Alarms Log
I/O Module Status
Command Options.
Each section includes command format, procedure, and options.
For notational convenience, the symbol nn is used to indicate the node number, in
the range of 1 through 13.
Defining Dial-Up Modem Parameters
D-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D.1 Defining Dial-Up Modem Parameters
Purpose
Defines the call-out parameters for the CM-2 dial-out port. The specified call-out
parameters are used by the CM-2 to build the call command that is sent to the
dial-up modem.
The modem connected to the out port must be set up as follows: (For
convenience, the Hayes commands required to select the specified parameters are
listed in brackets.)
•
•
At least 38.4 kbps per second dial modem
Modem reports call progress result codes: OK, CONNECT, RING,
NO CARRIER, NO ANSWER, ERROR, BUSY (AT X0)
•
•
•
•
•
•
Modem sends result code to DTE (AT Q0)
No echo (AT E0)
Modem sends long form result codes (AT V1)
DTR is ignored (AT &D0)
DSR forced on (AT &S0)
Escape code character must be + (AT S2=43).
Format
DEF CALL
Procedure
➤
To define the CM-2 call-out parameters:
•
Type: NODE 13 DEF CALL<Enter>.
The call-out parameters’ data form is displayed. A typical data form is shown in
Table D-1.
DIAL MODEM CONFIGURATION
DIAL MODEM STATUS: ACTIVE
COMMAND:
ATD
NUM OF RETRIES:
WAIT FOR CONNECT:
DIAL MODE:
2
60 SECS
TONE
29
PHONE NUMBER:
ALT NUM MODE:
ALT NUM:
YES
Figure D-1. Dial Modem Configuration Screen
D-2
Defining Dial-Up Modem Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
Command Fields
Table D-1 lists the fields appearing on the data form.
Table D-1. DEF CALL Fields
Field Name
Description
Options
DIAL MODEM STATUS
Sets the dial modem to active or inactive.
ACTIVE – Dial-up modem is
active
After you set the CM-2 to active status, it becomes
available for use after 10 seconds. A message is shown on
the terminal.
INACTIVE – Dial-up modem is
inactive
In order to change the modem from active to inactive,
disconnect the terminal port for about one minute.
COMMAND
Command to dial-up modem. For example, ATD.
Specifies the number of dialing retries:
NUM OF RETRIES
0 – No redial is attempted if
the call is not established on
the first attempt
NUM OF RETRIES applies to both the primary and the
alternate numbers as follows:
1 through 8 – If the call is not
established on the first
attempt, the CM-2 redials the
specified number of times.
•
If the call is not established after dialing the primary
number the specified number of times, the CM-2
attempts to establish the call by dialing the alternate
number (provided the use of an alternate number is
enabled by means of the ALT NUM MODE parameter
below).
•
If the call cannot be established with the specified
number of redialing attempts on either of the two
numbers, the CM-2 stops the call attempt. When a
new alarm report must be sent, the call attempts are
started again.
The user is notified about a failed call attempt by a
message recorded in the alarm buffer. Separate messages
are provided for each number called.
WAIT FOR CONNECT
Specifies time that the CM-2 waits for an answer after each 30, 45, and 60 seconds
dialing attempt. If the called station does not answer
Default value: 60 seconds
within the specified time, the CM-2 disconnects. If
additional call attempts are allowed, the CM-2 redials 30
seconds after disconnecting.
DIAL MODE
Selects dialing mode
TONE – The modem is
instructed to use DTMF dialing
The appropriate dialing mode to use depends on dialing
mode supported by the network.
PULSE – The modem is
instructed to use pulse dialing
PHONE NUMBER
Primary phone number
Defining Dial-Up Modem Parameters
D-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
Table D-1. DEF CALL Fields (Cont.)
Field Name
Description
Options
ALT NUM MODE
Enables dialing the alternate number.
NO – Dialing the alternate
number is disabled. CM-2
stops the call attempt after the
NUM OF RETRIES call
attempts on the primary
number have failed.
YES – Use of the alternate
number is enabled. The
alternate number is dialed
after the NUM OF RETRIES
call attempts on the primary
number have failed.
NA – Not available, same as
the value NO
ALT NUM
Alternate phone number
Returning to Terminal Mode
➤
To return to the terminal mode while the Dial Modem Status is Active:
1. Disconnect the modem from the terminal port.
2. Wait for one minute.
The Dial Modem Status automatically becomes INACTIVE.
D.2 Defining LRS-24 And CM-2 SNMP Agent Parameters
Purpose
Format
Defines or modifies the parameters of the CM-2 module (including the parameters
of the SNMP agent), and the general LRS-24 parameters. This command is always
addressed to the CM-2 module. Therefore the node address must always be 13.
The SNMP agent parameters must be defined before it is possible to manage the
LRS-24 using SNMP-based management stations. Refer to Appendix C for
additional information related to IP and SNMP parameters.
NODE 13 DEF HUB
Procedure
➤
To define the LRS-24 and SNMP agent parameters:
1. Type: NODE 13 DEF HUB<Enter>.
The first line of the data entry form (name entry form) appears.
2. Enter name of hub. Press <Enter> to store the data.
D-4
Defining LRS-24 And CM-2 SNMP Agent Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
3. Press <Tab> to move to the next field.
4. Continue until all the required lines have been filled in.
Note
SNMP community names are case-sensitive.
5. Press <Enter> to load all the data appearing on the screen into the CM-2
memory.
A typical data form is shown in Figure D-2.
LRS HUB SETUP
: 'name'
HUB NAME
HUB NUMBER
: '1234'
HUB LOCATION IS
: 'location'
: 'person'
CONTACT PERSON IS
CM CARD SOFTWARE VER : 0.0
INTERFACE CARD HW REV: 0.0
MAIN CARD HW REV : VER 2.0
TIME (HH:MM:SS)
IP ADDR
: 16:18:37
DATE
: 192.114.24.30 IP MASK
: PUBLIC
: 2000-05-23
: 255.255.255.0
READ COMMUNITY
TRAP COMMUNITY
: PUBLIC
READ/WRITE COMMUNITY : PUBLIC
DEFAULT GATEWAY
: 000.000.000.000
BURN IN MAC ADDRESS : 9920D2FE838D
BOOTP ON/OFF
BOOTP RETRIES
: OFF
: 30
BOOTP TIME OUT
HUB IP MODE
: 1 SEC
: MULTIPLE
SERIAL LINE PROTOCOL : RS232
STATION CLOCK
: INTERNAL CLOCK
Figure D-2. LRS Hub Setup
Command Fields
Table D-2 describes fields on the data form.
Table D-2. DEF HUB Command Fields
Field Name
Description
Options
HUB NAME
Logical name assigned to the LRS-24 unit.
Maximum 10 alphanumeric
characters
Default: LRS-24
HUB NUMBER
LRS-24 management number. The two least
significant digits are displayed on the STAT/ADD
display located on the front panel of the CM-2
module.
Mmaximum four hexadecimal
digits
Default: 5544
Defining LRS-24 And CM-2 SNMP Agent Parameters
D-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
Table D-2. DEF HUB Command Fields (Cont.)
Field Name
Description
Options
HUB LOCATION IS
Concise description of the hub location
Maximum 20 alphanumeric
characters
CONTACT PERSON IS
Name of person to be notified in case of problems
/contact information
Maximum 20 alphanumeric
characters
CM CARD SOFTWARE
VERSION
Software version of CM-2 module
MAIN CARD HW REV
INTERFACE CARD HW REV
TIME
Hardware version of CM-2 module
Hardware version of CM-2 interface module
Time of internal CM-2 real-time clock (the time is
correct for the instant the command has been
received by the CM-2 module).
Display format is
hours:minutes:seconds.
To change the time, type the correct time
according to the format: hh:mm:ss.
Set the time at least one minute beyond the current
time, so you will be able to press <Enter> at the
correct instant after completing all the fields on the
data form.
DATE
Date of internal CM-2 real-time clock.
Display format is
year:month:day.
To change the date, type the correct date
according to the format: YYYY-MM-DD. When
done, press <Enter> to move to the next field.
IP ADDRESS
IP address assigned to CM-2 module, in dotted-
quad format.
Four groups of digits in the
range of 0 through 255,
separated by periods
When assigning the IP address, remember that the
following 12 IP addresses must be reserved for I/O
modules (the first address will be associated with
I/O slot 1, and the last address with slot 12).
IP MASK
Subnet mask corresponding to the IP addresses
used by the CM-2 module
Dotted-quad format.
READ COMMUNITY
Name of SNMP community that has read-only
authorization (the CM-2 SNMP agent will accept
only getRequest and getNextRequest commands
from management stations using that community).
Up to seven alphanumeric
characters
READ/WRITE COMMUNITY
Name of SNMP community that has read-write
authorization (the CM-2 SNMP agent will also
accept setRequest commands from management
stations using that community).
Up to seven alphanumeric
characters
TRAP COMMUNITY
DEFAULT GATEWAY
Name of SNMP community to which the CM-2
SNMP agent will send traps
Up to seven alphanumeric
characters
IP address of default gateway to be used by CM-2
module to contact a management station located
on a different IP network.
Dotted-quad format
If the CM-2 module and the management station
are located on the IP same network, enter
0.0.0.0.
D-6
Defining LRS-24 And CM-2 SNMP Agent Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
Table D-3 DEF HUB Command Fields (Cont.)
Field Name
Description
Options
BURN IN MAC ADDRESS
Fctory MAC address used by BOOTP server to
declare the IP address of the CM-2.
BOOTP ON/OFF
Toggle to select BOOTP.
ON– use BOOTP
OFF–no BOOTP.
Default value: OFF
To maintain backwards compatibility (with any
LRS-12 version), set BOOTP ON/OFF to OFF.
Otherwise, BOOTP ON/OFF should be set ON.
In either case, BOOTP ON/OFF should be set to
OFF while setting the IP address.
BOOTP TIME OUT
Maximum waiting time for a BOOTP response
1, 2, 3, 4, 6, 8, 10, 15, 20
seconds.
Default value: 10 seconds
3, 4, 5, 10, 15, 20, 25, 30 times.
Default value: 30 times
BOOTP RETRIES
HUB IP MODE
Number of times to retry sending a request for the
BOOTP server
SINGLE – only one IP address.
(The LRS-24 address is the CM-2
address.). CM-2 receives SMOD
message and transfers to it to the
SMOD modem after adjusting
the IP. The IP is resolved from
the community field. In this
mode, ping and Telnet cannot
be used directly on an SMOD;
only the CM-2 IP address is
relevant.
MULTIPLE – normal mode.
Every SMOD has its own IP
address and the CM-2 does not
interfere at the IP level. Every
SMOD IP is calculated by
adding the CM-2 IP address and
the SMOD slot number.
SERIAL LINE PROTOCOL
STATION CLOCK
SLIP Protocol
RS232 – terminal
Internal
Set clock for station
External – Square
Ext-AMI
Defining LRS-24 And CM-2 SNMP Agent Parameters
D-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D.3 Defining Management Stations
Purpose
Define the list of management stations to receive traps generated by the CM-2
module. You can define up to 10 management stations, by specifying their IP
addresses. The trap community is defined by means of the DEF HUB command.
This command is always addressed to the CM-2 module, therefore the node
address must always be 13.
Format
NODE 13 DEF MNG
Procedure
➤
To define management stations that will receive traps:
1. Type: NODE 13 DEF MNG <Enter>.
The first line of the data entry form appears.
2. Type in the desired IP address in the dotted-quad format for each station to be
defined.
3. Press <Enter> to display the next line.
4. Continue until all 10 lines display the required addresses.
5. To delete an IP address, enter 000.000.000.000.
A typical data form is shown in Figure D-3.
HUB NMS TRAP UPDATE
No.
1
IP ADDR
192.114.24.45
2
192.114.24.70
3
000.000.000.000
000.000.000.000
000.000.000.000
000.000.000.000
000.000.000.000
000.000.000.000
000.000.000.000
000.000.000.000
4
5
6
7
8
9
10
Figure D-3. Hub NMS Trap Update Screen
D-8
Defining CM-2 Download Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
D.4 Defining CM-2 Download Parameters
Purpose
Controls the program version and allows four options:
•
•
Download via LAN
Download via XMODEM: Enables downloading the CM-2 program from the
XMODEM server.
•
•
Change the current version: Enables choosing which version will run after the
CM-2 automatically resets.
View the Version table: Displays the currently running version. The first version
on the table is currently running; the other two versions are backups. One — a
fixed version — is located in the EPROM. The other is located in Flash, and
can be altered.
Format
NODE 13 DEF DWL
Procedure
➤
To define CM-2 Download Parameters:
1. Type: NODE 13 DEF DWL <Enter>.
A typical data form is shown in Figure D-4.
DOWNLOAD MAIN MENU
1. CM2 or Modems Download via LAN
2. CM2 or Modems Download via XMODEM
3. Modems Download via CM2 FLASH
4. Change CM-2 software version
5. View existing versions in the CM2
Enter download option number ___>
Figure D-4. Download Main Menu
2. Select an option (see Table D-4).
The appropriate screen appears.
Defining CM-2 Download Parameters
D-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
Table D-4. Download Main Menu Options
Selection
Description
1
2
CM2 or Modems Download via LAN
Enables downloading the software version for CM-2 or modems from
the TFTP server
CM2 or Modems Download via MODEM Enables downloading the software version for CM-2 or modems via
XMODEM protocol (the terminal connected to the CM-2 must be
configured at 38.4 kbps, 8-bit, no parity, 1 stop bit)
3
Modems Download via CM2 FLASH
Enables downloading the software version for files that were previously
saved in CM-2 FLASH.
4
5
Change CM-2 software version
View existing versions in the CM2
Change to a different version of CM-2 software
View list of software versions
CM2 Download via LAN
➤
To download via LAN:
1. Type 1.
The Download via LAN screen appears.
Download via LAN
IP Address of TFTP server: 000.000.000.000
File name: Insert file name for download
Romote modems: N/A
Figure D-5. Download via LAN Screen
2. Type the TFTP server IP address – a dotted quad format (four groups of digits
in the range of 0 to 255, separated by periods).
3. Press <Enter> to store the data.
4. <Tab> to the File Name field.
5. Type the name of the file to be transferred to the CM-2 –supplied by RAD or
another authorized body.
6. Press <Enter> to store the data.
Note
After typing the data for all of the parameters, press <Enter> to start the download
process. After downloading, the CM-2 will perform a reset, and the new version will
be loaded. The CM-2’s seven-segment screen displays a rotating o until reboot is
complete.
D-10
Defining CM-2 Download Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
CM2 Download via XMODEM
In this option you can define one parameter. Remember that the terminal
connected to the CM-2 must be configured at 38.4 kbps, 8-bit, no parity,
one stop bit.
➤
To download via XMODEM:
1. Type 2.
Note
After typing the parameter data, press <Enter> to start the download process.
After the message “The CM-2 is waiting to the XMODEM data. Start the process
within one min.” appears, you must start the XMODEM server. When successful,
the message “The download action is done” appears. If after one minute the
XMODEM server has not connected properly to the CM-2, the message The
download action has failed appears.
CM2 Download via CM2 FLASH
➤
To download via CM2 FLASH:
1. Type 3.
MODEMS DOWNLOAD VIA CM2 FLASH
CM2 containing the following versions:
ID
1
Modem Type
NULL
Version No.
Date
Size
0k
Location
EMPTY
0.0
0.0
0.0
0- 0- 0
0- 0- 0
0- 0- 0
2
NULL
0k
EMPTY
3
NULL
0k
EMPTY
Please choose the ID number
1. ID NUMBER: 1
2. Download to Remote Modems: N/A
To change the ID number press f to scroll forward
or b to scroll backward
Figure D-6. Modems Download Via Cm2 Flash Screen
Change CM-2 Software Version
➤
To change CM-2 Software Version:
1. Type 4.
The Change CM2 Software Version screen appears.
Defining CM-2 Download Parameters
D-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
CHANGE CM2 SOFTWARE VERSION
CM2 containing the following versions:
ID
1
Version No.
Date
Size Location
3.0
3.0
3.0
2000- 3- 8
2000- 3- 8
2000- 2-16
353k FLASH1
353k FLASH2
353k EPROM
2
3
Please choose the ID number
1. ID NUMBER: 2
2. Password: This field is not applicable
To change the ID number press f to scroll forward
or b to scroll backward
NOTE: the first version (ID number 1) is the one we will run from
Figure D-7. Change CM2 Software Version
2. Press <F> (forward) or <B> (backward) to select the ID Number of the
version you want to run.
3. To exit the screen, without changing parameters, press <Esc>.
Note
Type the parameter data, and press <Enter> to start the download process. When
a version is selected, the CM-2 resets, and loads the chosen version. The CM-2’s
seven-segment screen displays a rotating o until the reboot is complete.
View CM-2 Software Version
➤
To view CM-2 Software Version:
1. Type 5.
The View CM2 Software Version screen appears.
D-12
Defining CM-2 Download Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
VIEW CM2 SOFTWARE VERSION
Appendix D CM-2 Management Commands
CM2 containing the following versions:
ID
1
Version No.
Date
Size Location
3.0
3.0
3.0
2000- 3- 8
2000- 3- 8
2000- 2-16
353k FLASH1
353k FLASH2
353k EPROM
2
3
VIEW MODEMS SOFTWARE VERSION ON CM2
CM2 containing the following versions:
ID
1
Modem Type
Version
9.3
Date
Size Location
230k FLASH3
230k FLASH2
230k FLASH1
ASMI-31CQ(m)
ASMI-31CQ(m)
ASMI-31CQ(m)
2000- 3- 5
2000- 2-15
2000- 3- 5
2
0.3
3
0.3
Figure D-8. View CM2 / Modems Software Version
The first line describes the version that is currently running.
D.5 Defining Modem Download Parameters
Purpose
Format
Controls the program version and allows six options.
NODE nn DEF MDL
nn is the slot number.
Procedure
➤
To define Modem Download Parameters:
1. Type: NODE 13 DEF MDL <Enter>.
A typical data form is shown in Figure D-4.
Defining Modem Download Parameters
D-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
MODEM DOWNLOAD MAIN MENU
1. Modem Download via LAN
2. Modem Download via XMODEM
3. Modem Download via CM2 FLASH
4. Modem Download via MODEM FLASH
5. Change Modem software version
6. View existing versions of Modem
Enter download option number ___>
Figure D-9. Modem Download Main Menu
Modem Download via LAN
➤
To download Modem via LAN:
Type 1.
The Modem Download via LAN appears (see Figure D-10).
•
DOWNLOAD via LAN
IP Address of TFTP server: 000.000.000.000
File name: Insert file name for download
Remote modem: N/A
Figure D-10. Modem Download via LAN
Modem Download via XMODEM
➤
To download Modem via LAN:
Type 2.
The Download via XMODEM appears (see Figure D-11).
•
DOWNLOAD via XMODEM
Remote modems: N/A
Figure D-11. Download via XMODEM
Modem Download via CM2 FLASH
➤
To download Modem via CM2 FLASH:
Type 3.
The Modems Download via CM2 Flash Screen appears (see Figure D-12).
•
D-14
Defining Modem Download Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
MODEMS DOWNLOAD via CM2 FLASH
CM2 containing the following versions:
ID
1
Modem Type
Version No.
Date
Size Location
230k FLASH3
230k FLASH2
230k FLASH1
ASMI-31CQ(m)
ASMI-31CQ(m)
ASMI-31CQ(m)
9.3
0.3
0.3
2000- 3- 5
2000- 2-15
2000- 2-15
2
3
Please choose the ID number
1. ID NUMBER: 1
2. Download to Remote Modems: N/A
To change the ID number press f to scroll forward
or b to scroll backward
Figure D-12. Modems Download via CM2 Flash Screen
Download to Remote Modem via Modem FLASH
➤
To download to remote modem via Modem FLASH:
Type 4
The Download To Remote Modem Via Modem Flash screen appears
(see Figure D-13).
•
DOWNLOAD TO REMOTE MODEM VIA MODEM’S FLASH
MODEM NAME: ASMI-31CQ(m)
MODEM STATUS
SELECT MODEM
: MASTER PERMANENT
: MODEM 1 LOCAL
Modem containing the following version:
ID
1
Version No.
0.1
Date
2000- 3- 8
2
EMPTY
3
EMPTY
Please choose the ID number
1. ID NUMBER: 1
To change the ID number press f to scroll forward
or b to scroll backward
Figure D-13. Download To Remote Modem Via Modem Flash
Defining Modem Download Parameters
D-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
Changing Modem Version
➤
To change the Modem Version:
Type 5.
The Changing Modem Version screen appears (see Figure D-14).
•
CHANGING MODEM’S VERSION
MODEM NAME: ASMI-31CQ(m)
MODEM STATUS
SELECT MODEM
: MASTER PERMANENT
: MODEM 1 LOCAL
Modem containing the following versions:
ID
1
Version No.
0.1
Date
2000- 3- 8
2
EMPTY
3
EMPTY
Please choose the ID number
1. ID NUMBER: 2
To change the ID number press f to scroll forward
or b to scroll backward
Figure D-14. Changing Modem Version
View Modem Version on Modem FLASH
➤
To view the Modem Version on Modem FLASH:
Type 6.
The View Modem on Modem FLASH screen appears (see Figure D-15).
•
VIEW MODEM ON MODEM’S FLASH
MODEM NAME: ASMI-31CQ(m)
MODEM STATUS
SELECT MODEM
: MASTER PERMANENT
: MODEM 1 LOCAL
Modem containing the following versions:
ID
1
Version No.
0.1
Date
2000- 3- 8
2
EMPTY
3
EMPTY
Figure D-15. View Modem on Modem Flash Screen
D-16
Defining Modem Download Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
D.6 Viewing Modem Version
Purpose
Views current version of modem in each slot of LRS-24 hub. This command is
relevant only for I-type modems.
Format
NODE 13 DSP VER
Procedure
➤
To view version of Modem software:
•
Type: NODE13 DSP VER <Enter>.
The Modem Version screen appears (see Figure D-16).
MODEMS VERSION
Slot/Modem
IO-03/1
IO-03/2
IO-03/3
IO-03/4
IO-08/1
IO-09/1
IO-10/1
IO-09/1
CM>2
NE Modem
NE Version
00.10
FE Modem
ASMI-31
FE Version
01.00
ASMI-31CQ(m)
ASMI-31CQ(m)
ASMI-31CQ(m)
ASMI-31CQ(m)
FOMi-E1/T1C(m)
ASMI-31CQ(m)
ASMi-24CQ(m)
ASMI-31CQ(m)
00.10
00.10
00.10
00.00
00.00
03.09
00.00
Figure D-16. Modem Version Screen
Table D-5. Modem Version Parameters
Parameter
Description
Slot/Modem
Slot number in LRS-24 chassis and Modem number:
1-2 for CD modems
1-4 for CQ modems)
NE Modem
NE Version
FE Modem
FE Version
Name of near-end (local) modem
Software version of near-end (local) modem
Name of far-end (remote) modem
Software version of far-end (remote) modem
Viewing Modem Version
D-17
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D.7 Defining I/O Module Management Parameters
Purpose
Defines general operational and access parameters for an I/O module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal, for example ASMi-24,
ASMi-30, ASMi-31, ASMi-32, etc. For such modules, the CM-2 module provides
the terminal interface.
Format
NODE nn DEF OPR
Procedure
➤
To define general and access parameters:
1. Type: NODE nn DEF OPR <Enter>.
nn stands for the module node number in the range of 1 through 12.
The first line of the module data entry form appears (see Figure D-17).
MODEM ADVANCED SETUP
MODEM NAME: ASMI-31CQ(m)
DEFINE MODEM PORT NUMBER
DEFINE STATUS
: 1
: MASTER PERMANENT
: MODEM 1 LOCAL
: DISABLE
SELECT MODEM
1) STOP STATUS UPDATE
2) CHANGE LOCAL MODEM STATUS
: MASTER
3) MANAGEMENT FROM REMOTE MODEM : NO
4) MDOEM MANAGEMENT LINK
5) LOAD CONFIGURATION FROM
: ENABLE
: N/A MODEM
6) I-TYPE (Far End Modem type) : YES
7) MODEM RESET
8) FACTORY RESET
9) CARD RESET
: NO
: NO
: NO
Figure D-17. Modem Advanced Setup Screen
Use the general procedures to define the parameter values, as required.
Note
The contents of the form depend on the module type. Refer to the Installation and
Operation Manual of the corresponding module for detailed information.
D-18
Defining I/O Module Management Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
D.8 Defining Card Configuration
Purpose
Format
Defines card type, name, and connection to a remote modem.
NODE 13 DEF CRD
Procedure
➤
To define card type, name, and connection:
•
Type: NODE 13 DEF CRD <Enter>.
Information about all the cards in the hub is displayed. A typical form is
shown in Figure D-18.
DEFINE CARD TYPE
Type Modem
Slot
Remote1 Remote2 Remote3 Remote4
Card 1 : EMPTY
Card 2 : EMPTY
Card 3 : IMODE
Card 4 : EMPTY
Card 5 : EMPTY
Card 6 : EMPTY
Card 7 : EMPTY
Card 8 : IMODE
Card 9 : IMODE
Card 10 : IMODE
Card 11 : IMODE
Card 12 : IMODE
NULL
NULL
LINKED
LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
LINKED LINKED LINKED
ASMi-31CQ(m) LINKED
NULL
NULL
NULL
NULL
LINKED
LINKED
LINKED
LINKED
FOMi-E1/T1C(m) LINKED
ASMi-31C(m)
ASMi-24C(m)
ASMi-31C(m)
ASMi-50C(m)
LINKED
LINKED
LINKED
LINKED
Figure D-18. Define Card Type Screen
Each slot number shows the type of modem, name, and connection to a remote
modem.
For parameters Type and Modem:
•
•
If Type is IMODE both fields are read-only.
If Type is EMPTY you can define Type and Modem name, only when in
Terminal Mode.
•
If Type is SMODE you can define Modem name.
Remote1 defines whether the modem is connected to (LINKED) or disconnected
from (UNLINKED) a remote modem. A double modem card, such as
FOMi-E1/T1CD, is defined for two remote modems - Remote1 and Remote2.
Defining Card Configuration
D-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
A card containing four modems, such as ASMI-31CQ, is defined for four remote
modems.
Note
When you select UNLINKED for Remote1, Remote2, Remote3, or Remote4, then
traps from the remote modem are masked.
D.9 Defining I/O Module Operational Parameters
Purpose
Defines the operational parameters for an I/O module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal, for example ASMi-24,
ASMi-30, ASMi-31, ASMi-32, etc. For such modules, the CM-2 module provides
the terminal interface.
Format
NODE nn DEF PRM
Procedure
➤
To define I/O Module Operational Parameters:
•
Type: NODE nn DEF PRM <Enter>.
nn stands for the node number of the desired module, in the range of
1 through 12.
The first line of the module data entry form appears (see Figure D-19).
D-20
Defining I/O Module Operational Parameters
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
MODEM SETUP
MODEM NAME: ASMI-31CQ(m)
DEFINE MAODEM PORT NUMBER : 1
MODEM STATUS
SELECT MODEM
SYNC/ASYNC
No. STOP BIT
PARITY
: MASTER PERMANENT
: MODEM 1 LOCAL
: SYNC
: N/A
: N/A
CHARACTER LENGTH
: N/A
: 128K
: N/A
DATA RATE
CD SENSE
CLOCK SOURCE LOC/REM: L(INT)R(RCV) EXT SOURCE: Modem #1
PORT: DCE-EXT
INTERFACE
: 2 WIRE
: YES
RTS/CTS DELAY (0:255) : N/A
RTS TO DCD
OUTPUT LEVEL
DTR TO DSR
INPUT LEVEL
INPUT IMPEDANCE
ERROR COLLECTION
AIS
: N/A
: N/A
: N/A
OUTPUT IMPEDANCE : N/A ohm
CARRIER CONTROL : N/A
RATE ADAPTION METHOD: PRIVATE
: N/A ohm
: N/A
: N/A
LINE CODING
T1 LINE LENGTH
BRIDGING
: N/A
: N/A
: N/A
PHANTOM
: N/A
ETHERNET NODE
: N/A
MASK SIGNAL STATUS : DATA : NO RTS:NO
TD: NO
RD: NO
LOS: NO
DCD : NO TEST: NO ERR: NO
Figure D-19. Modem Setup Screen
Use the general procedures to define the parameter values, as required.
Note
The contents of the form depend on the module type. Refer to the Installation and
Operation Manual of the corresponding module for detailed information.
D.10
Defining Supervision Terminal Type
Purpose
Defines the supervision terminal type.
This command enables the CM-2 module to provide the proper control codes to
the supervision terminal and in particular the codes for the following terminal
control functions:
•
•
Clear screen
Move cursor to screen home position
Defining Supervision Terminal Type
D-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
•
Move cursor to the right by one position.
The terminal types supported by the CM-2 module are: VT-52, VT-100, TV-920,
FREEDOM-100, FREEDOM-110, FREEDOM-220, and terminals that are
compatible with these types. Selecting an incorrect terminal type may prevent
correct display of data entry forms on the terminal.
Table D-6 shows the codes used by the supported terminals.
Table D-6. Terminal Types
Function
Terminal Type
TV- 920
VT-52
VT-100
Freedom-100
Freedom-110
Freedom-220
Clear Screen
Cursor Home
Cursor Right
1B2A0000
1E000000
0C000000
N/A
1B5B324A
1B5B4800
1B5B3143
1B2A0000
1E000000
0C000000
1B5B324A
1B5B4800
1B5B0143
1B480000
1B430000
This command is always addressed to the CM-2 module. Therefore the node
address must always be 13.
Format
NODE 13 DEF TRM
Procedure
➤
To configure the CM-2 module for the desired terminal:
•
Type: NODE 13 DEF TRM <Enter>.
The terminal selection form appears. A typical form is shown in
Figure D-20.
DEFINE TERMINAL TYPE
1. TV920
2. VT52
3. VT100
4. FREEDOM 100/110
5. FREEDOM 200
DEFAULT TYPE IS VT 100
ENTER TERMINAL TYPE No. -->
Figure D-20. Define Terminal Type Screen
➤
To select a terminal:
1. Type the corresponding number.
2. If the resulting display is not correct, try selecting another terminal.
D-22
Defining Supervision Terminal Type
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
D.11
Defining I/O Module Diagnostics
Purpose
Enables/disables a test or diagnostic function to be performed on a selected I/O
module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal, for example ASMi-24,
ASMi-30, ASMi-31, ASMi-32, etc. For such modules, the CM-2 module provides
the terminal interface.
Format
NODE nn DEF TST
Procedure
➤
To enable/disable a test or diagnostic function:
•
Type: NODE nn DEF TST <Enter>.
nn stands for the node number of the desired module, in the range of
1 through 12.
The first line of the data form appears. Use the general procedures to
define the parameter values, as required.
Note
The contents of the form depend on the module type. Refer to the Installation and
Operation Manual of the corresponding module for detailed information.
MODEM DIAGNOSTIC
MODEM NAME: ASMI-31CQ(m)
DEFINE MODEM PORT NUMBER
MODEM STATUS
: 1
: MASTERE PERMANENT
: MODEM 1 LOCAL
SELECT MODEM
LOOP & BERT
: CANCEL
: N/A
LOOP TIMEOUT : N/A
REMOTE DIG ENABLE
BERT RESULTS
: 0.0 E- 07
: OFF
LED TEST
LOCAL LOOP BACK
REMOTE LOOP BACK
REMOTE DIG
: N/A
: N/A
: N/A
ENABLE TEST FROM REM MODEM
BERT ERR INJECTION
: OFF
: N/A
Figure D-21. Modem Diagnostic Screen
Defining I/O Module Diagnostics
D-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D.12
Defining Auto-Configuration
Purpose
Defines Auto-Configuration for modems or LRS-24 hub:
•
•
For all the modems in the LRS-24 hub
For any number of modems, selected by type of modem, or specific list of
modems.
You can set other modems/hubs with the file configuration that ws created by a
specific modem/hub.
You can perform the following activities with the auto-configuration file:
•
•
•
•
Save to a file on the CM-2 or on a remote station for future use
Read to the screen
Write to a file
Send and receive to/from a station.
You can perform Auto-Configuration by file transfer or from a screen.
The number of files on CM-2 will be limited to available memory space (up to
three modem files and two hub files).
Error check and masking will be performed on the received file before the
configuration is executed.
Format
DEF CFG
Procedure
➤
To define the Auto-Configuration options:
Type: NODE 13 DEF CFG <Enter>.
The Auto-Configuration Menu screen appears (see Figure D-22).
AUTO CONFIGURATION MENU
1. Edit configuration
2. Send file to HUB
3. Create file from existing configuration
4. View configuration files in HUB
Enter Auto Configuration option number ->
Figure D-22. Auto Configuration Menu Screen
D-24
Defining Auto-Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
Editing the Configuration
You can edit existing individual modem configuration files that have been
previously saved or create a new file. You cannot edit or view the Hub
configuration files; they may only be sent or executed.
➤
To edit the Configuration:
1. Type 1 from the Auto-Configuration Menu.
The Edit Configuration screen appears (see Figure D-23).
2. Choose the number of the file that you want to edit, or type NEW.
− You can only edit modem files.
− If you choose NEW, a screen for a modem file appears with all the fields
listed as N/A.
− If you choose a Hub file, you will open a screen where you choose
operations for the file.
EDIT CONFIGURATION
Modem Configuration files:
ID
1
User String
test
Date
Size
1999-11-21 11:25:16
1999-11-21 11:59:01
1999-11-21 11:59:01
62 byte
68 byte
68 byte
2
asmi31tst
asmi31tst
3
HUB Configuration files:
4
5
hub1
hub2
1999-11-18 14:11:58
1999-11-18 14:12:20
0.4 Kbyte
0.4 Kbyte
A HUB file cannot be viewed on screen.
Please choose a file number or “NEW” for an empty screen: [1/2/3/4/5/NEW]
To select a file number press ‘f’ for forward or ‘b’ for backward.
Figure D-23. Edit Configuration Screen
Screen Fields
ID
File number
User String
Date
Name or remarks (up to 22 characters)
Date file was created
Size of file.
Size
Defining Auto-Configuration
D-25
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
Hub Configuration Operations
You can send or execute Hub Configuration files.
To execute a Hub Configuration file:
➤
1. Select 1 from the Auto-Configuration Menu.
2. Select file 4 or 5 (if the Hub files exist) in the Edit Configuration screen
(see Figure D-23).
The Operations for HUB Configuration screen appears (see Figure D-24).
OPERATIONS FOR HUB CONFIGURATION FILE
Execute file: [NO/YES]
Send file via: [N/A/TFTP/XMODEM]
To select an option press ‘f’ for forward or ‘b’ for backward.
Figure D-24. Operations For Hub Configuration File
3. Select YES to execute the configuration.
An error message is returned if the configuration specifies parameters but:
Slot is empty
Modem in slot does not exist
Type of modem in slot doesn’t match type in file configuration.
4. Select method for sending file to the station.
− N/A: file is not sent
− TFTP: Upload via LAN screen appears (see Figure D-25)
− XMODEM
5. Press <Enter> to continue the process.
Upload via LAN
IP Address of TFTP client: [000.000.000.000]
Filename: [Filename]
Figure D-25. Upload via LAN Screen
6. Enter station IP Address and Filename.
After the TFTP process has completed, a confirmation screen will appear
(see Figure D-26).
D-26
Defining Auto-Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
Send process: [size] byte transferred
The send process was completed successfully.
Figure D-26. Send Process Confirmation Screen
Editing a Modem File
➤
To configure a modem file:
1. Type 1 from the Auto-Configuration Menu.
The Edit Configuration screen appears (see Figure D-23).
2. Choose:
− NEW: a screen appears with all the fields listed as N/A (see Figure D-27)
− 1, 2, or 3: a screen appears with the parameters from the file you have
selected.
EDIT AUTO-CONFIGURATION
PARAMETERS:
SYNC/ASYNC
No. STOP BIT
PARITY
: N/A
CHARACTER LENGTH
DATA RATE
: N/A
: N/A
: N/A
: N/A
CD SENSE
: N/A
CLOCK SOURCE LOC/REM : N/A
EXT SOURCE : N/A
ALL PORTS : N/A
INTERFACE
: N/A
RTS/CTS DELAY (0.255) : N/A
RTS TO DCD
: N/A
DTR TO DSR
INPUT LEVEL
INPUT IMEDANCE
ERROR CORRCTION
AIS
: N/A
OUTPUT LEVEL
OUTPUT IMPEDANCE
CARRIER CONTROL
: N/A
: N/A
: N/A ohm
: N/A
: N/A ohm
: N/A
RATE ADATPTION METHOD : N/A
: N/A
LINE CODING
T1 LINE LENGTH
OPERATIONS:
MODEM RESET
: N/A
: N/A
PHANTOM
: N/A
: DISABLE
STOP STATUS UPDATE
:DISABLE
CHANGE LOCAL MODEM STATUS : MASTER
MODEM MANAGEMENT LINK : N/A
I-TYPE(Far_End Modem type): N/A
MANAGEMENT FROM REMOTE MODEM: N/A
LOAD CONFIGURATION FROM :N/A MODEM
Figure D-27. Edit Auto-Configuration for New Modem File
3. Enter information for the parameters.
If you do not enter any parameters, you receive an error message.
Defining Auto-Configuration
D-27
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
4. Press <Enter> to continue.
The third Edit screen appears for you to select operations for the file (see
Figure D-28).
EDIT AUTO-CONFIGURATION
Execute configuration: [NO/YES]
Save configuration to HUB: [NO/YES]
Send configuration via: [N/A/TFTP/XMODEM]
User String(Up to 22 characters): [UserString]
To select an option press ‘f’ for forward or ‘b’ for backward.
Figure D-28. Edit Auto-Configuration for New File – Second Screen
5. Select YES to execute the configuration.
6. Select YES to save the configuration.
7. To send the files, select the method: TFTP or XMODEM.
8. Enter a User String of up to 22 characters (optional).
➤
To execute the modem configuration file:
1. Select YES to Execute Configuration.
The Select Method for Configuration screen appears (see Figure D-29).
EDIT AUTO CONFIGURATION
Configure according to:
1. Modem Type
2. Specific Slot/Modem list
Enter option number - >
Figure D-29. Select Method for Configuration Screen
2. Select the configuration by type of modem or by a specific slot / modem list).
➤
To configure according to modem type:
1. Select Modem Type from Select Method for Configuration screen (see
Figure D-29).
The Auto-Configuration According to Modem Type screen appears (see
Figure D-30). Only those modems of the type you have selected, which are
currently in the Hub, can be chosen.
D-28
Defining Auto-Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
AUTO-CONFIGURATION ACCORDING TO MODEM TYPE
Execute configuration for all modems of type:
1. Asmi50
5.
2. Asmi24
6.
3.
7.
4.
8.
Press Enter to choose type. Repeated choice will delete it from the list.
To continue press <tab>.
Figure D-30. Auto-Configuration According To Modem Type Screen
2. Press <F> to tab forward or <B> to tab backwards.
3. Press <Enter> to select a Modem Type.
The selected type will be displayed in the list. To delete it from the list,
select it a second time.
4. Press <Tab> for execution.
➤
To configure according to a specific slot/modem list:
1. Select Specific Slot/Modem list from Select Method of Configuration screen
(see Figure D-29).
The Auto-Configuration According to Slot / Modem List screen appears
(see Figure D-31).
Defining Auto-Configuration
D-29
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
AUTO-CONFIGURATION ACCORDING TO SLOT/MODEM LIST
Execute configuration for SLOT [NUMBER]
MODEM [NUMBER]
--------------------------------------------------------------------
Modem
1
1
2
2
3
3
4
4
Slot all local remote
1
local remote
local remote
local remote
2
3
4
5
6
7
8
9
10
11
12
Press Enter to choose option. Repeated choice will delete it from the list.
To continue press <tab>.
Figure D-31. Auto-Configuration According To Slot/Modem List Screen
The screen appears with blank fields.
Each slot can hold a modem card that contains:
− A single modem
− Two modems
− Four modems.
2. Enter Slot Number by pressing <F> for forward or <B> for backward.
3. <Tab> from Slot to Modem.
4. Enter Modem Number.
5. Press <Enter>.
An X appears in the correct place in the table. To delete it from the list,
select it a second time.
6. Select ALL if you want to configure all the modems in the slot (this includes
local and remote for all modems on the card).
7. To continue, press <Tab>.
D-30
Defining Auto-Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
Sending Configuration Files
➤
To send a configuration file to the LRS-24 hub:
1. Type 2 on the Auto-Configuration Menu.
The Send File to Hub screen appears (see Figure D-32).
SEND FILE TO HUB
Send file via: [N/A/TFTP/XMODEM]
Save file to HUB: [NO/YES]
Execute configuration: [No/YES]
To elect an option press ‘f’ for forward or ‘b’ for backward.
Figure D-32. Send File To Hub Screen
2. Select at least one of the following:
− YES to save the file.
− YES to execute the file (see Hub Configuration Operations/Editing the
Configuration.
➤
To send the file by TFTP:
1. Select TFTP.
The Download via LAN Screen appears (see Figure D-33)
Download via LAN
IP Address of TFTP server: [000.000.000.000]
File name: [filename]
Figure D-33. Download via LAN Screen
2. Enter the IP Address of TFTP server and File name.
A download confirmation message appears (see Figure D-34)
Download progress: [size] byte transferred
The download action was completed successfully.
Figure D-34. Download Confirmation message Screen
➤
To send file by XMODEM:
1. Select XMODEM.
A message appears that you can start sending the file (see Figure D-35)
CM2> The CM2 is waiting to the XMODEM data: start the process within one min
Figure D-35. Start Sending the File Message
2. If Execute was selected, the process will continue as described in Hub
Configuration Operations/Editing the Configuration.
Defining Auto-Configuration
D-31
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
Creating Files from an Existing Configuration
➤
To create a file from the existing configuration:
1. Type 3 from the Auto-Configuration Menu.
The Create File Form Existing Configuration screen appears (see
Figure D-36).
CREATE FILE FORM EXISTING CONFIGURATION
Create file from: [HUB/MODEM]
Slot: [NUMBER] Modem: {NUMBER} (relevant only for modem files)
User String(up to 22 characters): [user_string]
Save file to HUB: [NO/YES]
Send file via: [N/A/TFTP/XMODEM]
To select an option press ‘f for forward or ‘b’ for backward.
Figure D-36. Create File Form Existing Configuration Screen
2. Select method to create file:
− HUB: the file configuration is created from all the modems that are
presently in the hub. The cursor jumps to User String.
− MODEM: enter the Slot Number and Modem Number of the modem
whose configuration you want to save.
3. Select YES if you want to save the file.
4. If you want to send the file, select the method for sending the file to the
station:
− TFTP: the Upload/Download via LAN screen appears (see Figure D-33)
− XMODEM: a message appears that you can start receiving the file
(see Figure D-35).
Viewing Configuration Files in the Hub
➤
To view configuration files in the LRS-24 hub:
•
Type 4 from the Auto-Configuration Menu.
The View Configuration Files in Hub screen appears (see Figure D-37).
D-32
Defining Auto-Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
VIEW CONFIGURATION FILES IN HUB
Modem Configuration files:
ID User String
Date
Size
1
2
3
test
1999-11-21 11:25:16
1999-11-22 11:59:01
1999-11-22 11:59:01
62 byte
68 byte
68 byte
asmi31tst
asmi31tst
HUB Configuration files:
4 hub1
5 hub2
CM2>
1999-11-18 14:11:58
1999-11-18 14:12:20
0.4 Kbyte
0.4 Kbyte
Figure D-37. View Configuration Files in Hub Screen
D.13
Displaying General Alarm Status
Purpose
Displays the general alarm status of the LRS-24.
This command is always addressed to the CM-2 module. Therefore the node
address must always be 13.
Format
NODE 13 DSP ALM
Procedure
➤
To display the LRS-24 alarm status:
•
Type: NODE 13 DSP ALM <Enter>.
The alarm status display form appears. A typical form is shown in
Figure D-38.
Displaying General Alarm Status
D-33
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
HUB ALARM
POWER SUPPLY A: FAIL
POWER SUPPLY B: FAIL
CARD STATUS CHANGE: N/A
CURRENT MANAGEMENT: TERMINAL
MODEM IN SLOT 1 HAS ACTIVE ALARM : N/A
MODEM IN SLOT 2 HAS ACTIVE ALARM : N/A
.
.
.
.
MODEM IN SLOT 12 HAS ACTIVE ALARM : N/A
STATION CLK – SQUARE LOSS SIGNAL : YES
STATION CLK – AMI LOSS SIGNAL
: YES
Figure D-38. Hub Alarm Screen
Display Format
The Alarm Status is displayed as a table that shows relevant information related to
the LRS-24:
•
One line is provided for each power supply module and for I/O module slot.
The line indicates whether the corresponding power supply module operates
normally (OK) or failed (FAIL), and whether an active alarm condition is
present in each module.
You can display the last 256 alarms using the DSP LOG command. To display
the alarms of a specific module, use the DSP ALT command.
•
•
The CARD STATUS CHANGE line displays YES if a status change has been
detected in the LRS-24.
The CURRENT MANAGEMENT line indicates the management system that
controls the LRS-24, as shown in Table D-7.
Table D-7. Current Management Fields
Message
Description
TERMINAL
NMS
LRS-24 is managed by the terminal
LRS-24 is managed by a network management station
REMOTE MODEM
Parameters of the modules installed in the LRS-24 are
determined by the remote equipment connected to each
module
D-34
Displaying General Alarm Status
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
D.14
Displaying I/O Module Alarm Status
Purpose
Displays the status and the alarms for a specific I/O module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal, for example, ASMi-24,
ASMi-30, ASMi-31, ASMi-32, etc. For such modules, the CM-2 module provides
the terminal interface.
Format
NODE nn DSP ALT
Procedure
➤
To display I/O Module Alarm Status:
•
Type: NODE nn DSP ALT <Enter>.
nn stands for the node number of the desired module, in the range of
1 through 12.
The status and alarm display form for the specified module appears.
The contents of the form depend on the module type.
Refer to the Installation and Operation Manual of the corresponding module for
detailed information.
Displaying I/O Module Alarm Status
D-35
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
MODEM ALRAM STATUS
MODEM NAME: ASMI-31CQ(m)
: 1
DEFINE MODEM PORT NUMBER
SELECT MODEM
: MODEM 2 LOCAL
: OFF
LINE DISCONNECT
REMOTE MODEM POWER OFF
TRANSMIT CARRIER
RECEIVE CARRIER
: OFF
: OFF
: OFF
LLB BY DTE
: OFF
RLB BY DTE
: OFF
SYNC LOSS
: ON
CONFIGURATIO MISMATCH
NVRAM FAILED
: OFF
: OFF
ILLEGAL EXTERNAL CLOCK SOURCE
NO MANGEMENT LINK
NO MODEM PORT (IR)
NO FIBER INTERFACE
IR RATE MISMATCH
ELF TEST FAILED
: ON
: ON
: OFF
: OFF
: OFF
: OFF
: OFF
: OFF
: OFF
LAN NOT CONNECTED
: OFF
: OFF
: OFF
: OFF
: OFF
: OFF
: OFF
NO EXT CLK INPUT
ILL. CLK-ERR
OLD REM VERSION
WRONG CONNECTION
ASI-OPT
XILINX FAILES
MINOR ALARM – AIS-ELC
MAJOR ALARM – LINE DISCON.-ELEC
LINE DISCON.-OPT
Figure D-39. Modem Alarm Status Screen
D.15
Displaying System Status
Purpose
Format
Displays LRS-24 system information.
This command is always addressed to the CM-2 module. Therefore the node
address must always be 13.
NODE 13 DSP HUB
➤
To display current system information:
•
Type NODE 13 DSP HUB <Enter>.
A typical display is shown in Figure D-40.
D-36
Displaying System Status
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
LRS-24 CARDS
NAME
(Device name – LRS-12)
SLOT NO.
01
TYPE
EMPTY
EMPTY
IMOD
EMPTY
EMPTY
EMPTY
EMPTY
IMOD
IMOD
IMOD
IMOD
IMOD
CM-2
PS-B
PS-A
IP
02
03
ASMi-31CQ(M)
192.168.216.156
04
05
06
07
08
FOMI-E1/T1C
ASMI-31C
ASMI-24C
ASMI-31C
ASMi-50C
192.168.216.156
192.168.216.156
192.168.216.156
192.168.216.156
192.168.216.156
192.168.216.156
192.168.216.156
192.168.216.156
09
10
11
12
13
14
EMPTY
15
120W/AC_P
Figure D-40. Module Status Screen
Table D-8 describes the fields in the display.
Table D-8. Module Status Fields
Data
SLOT
TYPE
Description
Displays the number of the LRS-24 slot
Indicates the management capabilities of module installed in the slot:
SMOD – The module supports direct management by SNMP or by
supervision terminal.
IMOD – The module can only be managed through the CM-2 module (for
such modules, the terminal interface is provided by the CM-2 module)
EMPTY – No module is installed in the slot
NAME
IP
Indicates the type of module installed in the slot
Displays the IP address used for managing the corresponding module:
For SMOD modules, displays the IP address assigned to its SNMP agent
For IMOD modules, displays the IP address assigned to the CM-2 SNMP
agent
No information is displayed for empty slots
Displaying System Status
D-37
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D.16
Displaying Alarms Log
Purpose
Displays the contents of the alarm history buffer of the CM-2 module, or of other
selected I/O module. This buffer contains the last 20 alarms and events (for
example, module insertion/removal).
The alarm log is cleared automatically when LRS-24 is turned off.
Format
NODE nn DSP LOG
Procedure
➤
To display the desired log:
•
Type: DSP nn DSP LOG <Enter>.
nn stands for the node number of the desired module, in the range of
1 through 12.
The log of the specified module appears.
The contents of the form depend on the module type. Refer to the Installation and
Operation Manual of the corresponding module for detailed information.
A typical alarm display for the hub log, displayed in response to a request
addressed to the CM-2 module (node 13), is shown in Figure D-41.
MODEM LOG FILE
MODEM NAME: ASMI-31CQ(m)
DEFINE PORT NUMBER
SELECT MODEM
: 1
: MODEM 1 LOCAL
CODE STATE DESCRIPTION
TIME
DATE
12
08
12
OFF
OFF
ON
NearEndMngLinkFail 09:01 2000-03-09
NearEndSyncLoss
NearEndSyncLoss
09:01 2000-03-09
09:01 2000-03-09
THERE ARE NO MORE PAGES AT THE MOMENT
Figure D-41. Hub Log File Screen
D-38
Displaying Alarms Log
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
D.17
Displaying I/O Module Status
Purpose
Displays complete status and diagnostic information for selected I/O module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal. For such modules, the CM-2
module provides the terminal interface.
Format
NODE nn DSP STT
Procedure
➤
To display the information:
•
Type: DSP nn DSP STT <Enter>.
nn stands for the node number of the desired module, in the range of
1 through 12.
The status and diagnostic information data form for the specified module
appears.
The contents of the form depend on the module type. Refer to the Installation and
Operation Manual of the corresponding module for detailed information.
MODEM STATUS
MODEM NAME
DEFINE MODEM PORT NUMBER
: ASMI-31CQ(m)
: 1
SELECT MODEM
INTERFACE MODULE
MODEL PORT
: MODEM 1 LOCAL
REMOTE MODEM : ASMI-31
: SCASI-68 & RJ11*4 REMOTE SLOT : N/A
: RS-530
: 00.10
: 00.00
REMOTE MODEM LINE CONNECTOR: TERM. BLOCK
REMOTE MODEM FRONT PANEL : LCD
HW PANEL VERSION : 03
SW VERSION
HW VERSION
LED STATUS: 1) RTS OFF 2) DCD OFF 3) TEST OFF 4) ERR OFF
5) ELE-LOW ---- 6) ELE-AIS ---- 7)OPT-LOW ---- 8)OPT-AIS ----
LINK QUALITY
BPV ERROR
: GOOD
: 37 E+01
: 37 E+01
: 00 %
: 0
PS PHANTOM STATUS
CHASSIS
: N/A
: N/A
: N/A
FIBER OPTIC ERROR
LINE UTILITY
BERT RUN TIME
BERT SYNC LOSS
WAVE LENGTH
BERT ERR SECONDS
BERT PRE FEC
: 0
: 0
: 0
: 0
BERT POST FEC
Figure D-42. Modem Status Screen
Displaying I/O Module Status
D-39
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D.18
Define CM-2 Reset
Purpose
Format
Remote reset for CM-2 card.
NODE 13 DEF RST
Procedure
➤
To reset the CM-2 card:
1. Type: NODE 13 DEF RST <Enter>.
A confirmation screen appears.
CM-2 RESET CONFIRMATION
DO YOU REALLY WANT TO RESET CM-2 : NO
Figure D-43. CM-2 Reset Confirmation Screen
2. Select YES or NO.
D.19
Define Password
Purpose
Defines password.
Default password: radlrs.
Format
NODE 13 DEF PWD
Procedure
➤
To define the password:
1. Type: NODE 13 DEF PWD<Enter>.
The Password Menu screen appears (see Figure D-44).
D-40
Define Password
Download from Www.Somanuals.com. All Manuals Search And Download.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
PASSWORD MENU
Enter new password
Enable password
: radlrs
: NO
Figure D-44. Password Menu Screen
2. Type password.
3. Select YES or NO to Enable Password.
D.20
Displaying Command Options
Purpose
Displays an index of the supervisory port commands and the options available for
each command.
Format
NODE 13 HLP
Procedure
➤
To enter the help system:
1. Type: HLP <Enter>.
The help page appears (see Figure D-45). The page consists of two
sections:
The top section displays the commands available for modules that do
not support direct management by SNMP or by supervision terminal.
The bottom section displays the commands available for the CM-2
module.
Displaying Command Options
D-41
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
HUB TERMINAL COMMANDS
DEF TST – MODEM DIAGNOSTIC.
DSP ALT – MODEM ALARM STATUS.
DSP LOG – MODEM LOG FILE.
DEF MDL – MODEM DOWNLOAD MENU.
- - - - - - - - - - - - - - - - - - - - - -
DEF HUB – LRS HUB SETUP.
DSP HUB – MODULE STATUS.
DEF MNG – HUB NMS TRAP UPDATE.
DSP ALM – HUB ALARM.
DSP LOG – HUB LOG FILE.
DEF TRM – DEFINE TERMINAL TYPE.
DEF CRD – DEFINE CARD TYPE IN SLOT.
DEF DWL – DEFINE AND VIEW PARAMETERS FOR DOWN LOAD.
DEF CALL– DEFINE PARAMETERS FOR DIAL OUT MODEM.
Press any key to continue. . .
Figure D-45. Hub Terminal Commands Screen
2. Press any key to continue viewing the lists of commands (see Figure D-46).
DEF RST – DEFINE RESET OF THE CM-2 CARD
DEF CFG – AUTO CONFIGURATION OPERATIONS.
DEF PWD – DEFINE THE TELNET PASSWORD.
DSP VER – DISPLAY THE MODEMS (IMOD ONLY) VERSION.
BEFORE EACH COMMAND, PLEASE INDICATE THE MODE YOU WANT TO WORK WITH.
CM2>
Figure D-46. Hub Terminal Commands Screen (Cont.)
D-42
Displaying Command Options
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Appendix D CM-2 Management Commands
Table D-9. Hub Terminal Commands Screen
Description
Command
DEF TST
Modem diagnostic
DSP ALT
DSP LOG
DEF MDL
DEF HUB
DSP HUB
DEF MNG
DSP ALM
DSP LOG
DEF TRM
DEF CRD
DEF DWL
DEF CALL
DSP VER
DEF RST
Modem alarm status
Modem log file
Modem download menu
LRS hub setup
Module status
Hub NMS trap update
Hub alarm
Hub log file
Define terminal type
Define card type in slot
Define and view parameters for download
Define parameters for dial out modem
Displays modem versions
Defines reset
DEF CFG
DEF PWD
Defines Auto-Configuration
Define password
Displaying Command Options
D-43
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D-44
Displaying Command Options
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Index
—A—
node ID, 4-11
Abstract Syntax Notation 1 (ASN.1), C-2, C-3
AC module, 1-12, 2-16
Address Resolution Protocol (ARP), C-7
alarms, 1-5, 2-26, 4-7, 4-12, 5-1, C-2, D-34
buffer, D-38
log, displaying, D-38
relay, 2-26, A-3
status, 4-12
status display, D-33
ambient requirements, 2-5
ANSI racks, 1-6, 1-12, B-1, B-2, B-4
ASCII terminal management, 1-4, 1-5, 1-13, 3-2,
4-1, 4-2, 4-3, 4-4, 4-6, C-6
ASM-40CD, 1-5
operating instructions, 2-28–2-30
parameters, 2-29, D-2, D-4
SNMP, C-1
CM-2 Reset, D-40
command options, displaying, D-41
commands, CM-2, 4-12, 4-10–4-13
common logic modules, 1-11, 1-12–1-14
communication parameters
CM-1, 3-5
communities
CM-2, C-4
SNMP, C-3–C-4, D-6
configuration, 4-5, 4-6
CM-1, 3-4, 3-5
Auto Configuration, D-24
CM-2, 4-1, 4-13
I/O module, 4-13
individual modules, 3-5, 4-14
SNMP, 1-13
—C—
cables, 4-7
Card Configuration, D-19
chassis, 1-11, 1-14
circuit breaker, 2-4, 2-25, B-3, B-5
clock, 1-5, 1-15, 2-11, 2-15, 2-18, 2-19, 2-22,
2-26, A-1, A-3
Clock, 1-15, 2-11, A-1, A-3
CM-1 module
connectors, 1-4, 2-16, 2-19, 4-7, 4-13
AC power, 2-7
Ethernet, 2-22, 2-26
LRS-PS-FEED, B-1, B-5
PHANTOM, 2-16, 2-25
PS module, A-4
remote feed, 2-16
RJ-45, 2-19
RS-232, 2-18, 2-26, 3-2, 3-3, 3-5, 4-7
station clock, 2-11, 2-15, 2-18, 2-19, 2-22, 2-26, A-1,
A-3
UTP, 2-21
corrections, 4-11
communication parameters, 3-5
connection via modem, 3-3
functions, 3-1
installation, 2-8–2-12
management, 1-5, 1-10, 1-12, 1-13
supervision terminal operation, 3-4–3-5
CM-2 module
cross cable, 2-21, 3-2, 3-3, 4-7
cursor, 4-11, D-22
alarm buffer, D-38
alarm status, D-33
capabilities, 4-1
—D—
commands, 4-10–4-13
communities, C-4
configuration, 4-13
cross cable, 4-7
default gateway, D-6
failure, 4-3
initialization, 4-5–4-6
management, C-6
data storage, 4-3
DC PS modules, 1-12
diagnostic tests, 5-1
displaying alarm status, 4-12, D-33
Download, D-9
duplex communication, 4-11
I-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Index
LRS-24 Installation and Operation Manual
—E—
—J—
jumper settings, 2-15
enclosure, installation, 2-24–2-27
error code, 2-29
—L—
errors, 2-29, 4-11, 4-12
LAN, 1-5, 1-16, 2-19, 2-21, 2-22, 4-7, D-9, D-14
LRS-24B, 1-6, 1-7, 1-10
LRS-24F, 1-6, 1-9, 1-10
LRSI-F1-CM2
Ethernet, 1-5, 1-13, 1-16, 2-19, 2-21, 2-22, 2-26,
2-30, 4-2, 4-3, 4-7, A-4, C-6, C-7
ETSI racks, 1-4, 1-9, 2-24, B-1, B-4
installation, 2-18–2-21
—F—
failure, CM-2, 4-3
features of LRS-24, 1-4
feed voltage, phantom, 1-12, 2-25, 2-27, 2-28, 2-
LRSI-F2-CM2, 4-2, 4-7, A-4, C-4, C-7
installation, 2-24
LRSI-F-CM1 module, 2-17–2-18, 3-3, 3-5, A-1,
A-2
LRSI-PSP module, B-1, B-5
LRS-PS FEED, power supply, B-1–B-5
LRS-PS module, B-1
29
front clearance, 2-5
—H—
LRS-PS-FEED, B-1–B-5
HELP, D-41
help, CM-2, 4-11
HPOV, 1-5
—M—
MAC address, C-4, C-7, D-7
malfunction, 2-28, 2-29
management
ASCII, 1-4, 1-13, 3-2, 4-1, 4-2, 4-3, 4-4, 4-6, C-6
ASCII terminal, 1-5
CM-2, C-6
dumb terminal, 1-5
Ethernet connectors, 2-26
MDM, 1-5
—I—
I/O (user) modules, 1-11, 1-14, 2-28
configuration, 3-5, 4-13
connectors, A-1
diagnostics, defining, D-23
display status, 4-12
IP address, C-6, C-7
messages, C-7
RADview-PC/MDM, 1-5
RS-232 connectors, 2-26
SNMP, 1-4, 1-5, 1-13, 4-3, 4-16, C-1, C-6
Telnet, 1-13
node number, 4-4
parameters, D-20
parameters, D-18
status, D-39
Management Information Base (MIB), 4-16, C-2,
C-3, C-7
I/O (User) modules
connectors, 2-27
management stations
defining, 1-12, 4-2, 4-3, 4-5, 4-12, 4-14, 4-16, C-3,
C-4, D-4, D-6, D-8
SNMPI, 4-1
MDM management, 1-5
memory, 4-3, D-5
message format, CM-2, 4-3
MIB. See Management Information Base
Modem Alarm Status, D-35
modem cards, 1-5
IMOD module, 4-14, D-37
index of commands,CM-2, 4-12
indicators, 1-5, 2-9, 2-13, 2-27, 2-28, 2-29, 5-1, B-
5
initialization, CM-2, 4-5–4-6
installation
CM-1, 2-12, 3-4
interface modules, 2-17
LRS-24 enclosure, 2-24
LRSI-F2-CM2, 2-21
LRSI-F-CM-1 module, 2-17–2-18
PS modules, 2-16–2-17
Installation, B-4
interface modules, A-1, C-6
interface, CM-2 and SNMP, 4-2
internal settings, 2-20, 2-22
Internet Activities Board (IAB), C-2
Internet Protocol (IP), 1-13, 2-16, 4-3, C-1, C-4–C-
7, C-5, D-4, D-5, D-6, D-7, D-8, D-10, D-37
IP environment, C-4
Modem Download, D-13
modem link, CM-1, 3-3
Modem Version, D-17
modems, 1-1, 1-5, 3-1, 3-2, 3-3, 4-7, 4-12, D-2,
D-3, D-4, D-7
module identification
CM-2, 4-2
module slots, 1-10
Module Status, D-39
modules:. See individual modules
IP Environment, C-4–C-7
I-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
LRS-24 Installation and Operation Manual
Index
—N—
network management station, RADview, 4-1
node ID, CM-2, 4-11
RJ-45 connector, 2-19, 2-26
routing, CM-2, 4-3
node number, 3-1, 4-4, 4-11, 4-15, D-18, D-20,
D-23, D-35, D-38, D-39
RS-232, 3-1, 3-2, 3-3, 4-1, 4-6, 4-7, 4-13, A-2
connectors, 2-18, 2-26, 3-5
interface, 3-2
—O—
operating instructions
CM-1 supervision terminal, 3-4–3-5
CM-2 module, 2-28–2-30
operating temperature, 2-5
operational parameters, I/O module, D-20
—S—
scrolling values, 4-12
settings, internal, 2-20, 2-22
SLIP, 4-3, C-4, C-6, C-7
SMOD module, 4-14, D-7, D-37
SNMP, 1-4, 1-5, 1-13, 1-15, 1-16, 4-1, 4-2, 4-3,
4-4, 4-5, 4-1–4-5, 4-11, 4-12, 4-15, 4-16, B-1,
C-1, D-4, D-5, D-6, D-18, D-20, D-23, D-37,
D-39, D-41
—P—
package contents, 2-5–2-6
parameters, 4-3, 4-5, 4-12, 4-13, 4-14, 4-15
CM-1 communication, 3-5
CM-1 configuration, 3-4
CM-2, 2-29, 4-2, D-2, D-4
communities, D-6
configuration, 1-13
internal agent
configuration, 4-1, 4-4, 4-5, 4-6, 4-13
default communication, 3-4
I/O (user) module, D-18
initialization, CM2, 4-3
RS-232, 3-2
in CM-2, 4-1
management, C-1, C-6
SNMP agent parameters, defining, 4-5, D-4
station clock, 2-11, 2-15, 2-18, 2-19, 2-22, 2-26,
A-1, A-3
SNMP agent, 4-5, D-4
supervision terminal, 3-1, 3-2, 3-3
Password, D-40
passwords, 3-4
change, 3-5
CM-1, 3-3
CM-1 module operation, 3-4–3-5
defining, 4-12, D-21
default, 3-4
System Status, D-36
phantom feed voltage, 1-12, 2-25, 2-27, 2-28,
2-29
pin function, 2-27, A-1, A-2, A-3, A-4
—T—
TD indicator, 2-9, 2-13, 2-27, 2-29
terminal connection, CM-1, 3-2
terminal echo, 3-4, 4-11, 4-13
tests, diagnostic, 5-1
traps, C-1, C-3, C-4, D-8
SNMP, C-7
troubleshooting, 2-28
CM-1 modules, 2-28
CM-2 modules, 2-29
polarity, 2-25, B-5
power supply, 1-4, 1-5, 1-11, 1-12, 1-14, 2-1, 2-4,
2-5, 2-7, 2-9, 2-13, 2-16, 2-24, 2-25, 2-26, 2-
27, 2-28, 2-29, 4-3, 4-5, 4-6, A-4, B-1, B-2, B-3,
B-5, C-7, D-34
preliminary configuration, 3-4, 3-5, 4-1, 4-2, 4-4,
4-5, 4-6, 4-14, 4-15, C-7
prompt, 4-11, 4-14, 4-15
PS modules, 1-10, 1-11, 1-12, 2-6, 2-7, 2-16,
2-24, 2-27, 2-28, 2-29, A-1, A-4
installed modules, 2-28
turn off, 2-28, 2-29, 4-13
turn on, 2-27, 2-28
—R—
RADview, 4-1
RADview-PC/MDM management, 1-5
RD indicators, 2-27
remote module, 4-3, 4-4, 4-6
remote power source, 1-12, B-1
remote units, controlling, 1-5, 2-16
—U—
unpacking, 2-5–2-6
User Datagram Protocol (UDP), C-1, C-6
—X—
XMODEM, D-9, D-14
I-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
Index
LRS-24 Installation and Operation Manual
I-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Ph:727-398-5252/Fax:727-397-9610
Order from: Cutter Networks
www.bestdatasource.com
|