BB5A/BB5L Series
Spectra™ Lite,
Spectra™
(Software Version 3.0)
and
Spectra II™ Domes
Back Box
Installation/
Operation Manual
C1488M-A (9/98)
U
®
L
LISTED
®
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-209) 292-1981 or FAX (1-209) 348-1120 • DataFAX (1-209) 292-0435
Download from Www.Somanuals.com. All Manuals Search And Download.
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be
observed.
1. Installation and servicing should only be done by qualified service personnel
and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or
6P enclosure, it is designed for indoor use only and it must not be installed
where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis-
tance measurement between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four
times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C1488M-A (9/98)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 REGULATORY NOTICES
NOTE: This equipment has been tested and found to comply with the limits of a
Class B digital device, pursuant to part 15 of the FCC rules. These limits are de-
signed to provide reasonable protection against harmful interference in a residen-
tial installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However there is no guarantee that
the interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try and cor-
rect the interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
4
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
1.3 UNPACKING INSTRUCTIONS
Unpack and inspect all parts carefully.
Be sure to save the shipping box and any inserts. They are the safest material in
which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its box
and contact the factory at 1-800-289-9100 or 1-209-292-1981 for a replacement.
(International customers fax 1-209-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY
AND RETURN section of this manual for instructions.
The following items are supplied:
IN-CEILING MODELS
1
1
1
Back box
Installation/Operation Manual (C1488M)
Parts bag (refer to Figure 1)
1
1
1
1
4
Conduit fitting
Safety chain bracket
Lock nut
Compass tool
T-rail clip (clip, L-bracket, screw, lock washer, nut)
PENDANT MODELS
1
1
1
Back box
Tube of pipe sealant
Installation/Operation Manual (C1488M)
1.4 RECOMMENDED TOOLS
Pelco does not supply basic tools needed for the installation process.The following
tools are recommended:
Small flat screwdriver
Coaxial cable stripper
BNC crimp tool
Wire stripper
Wire cutter
Pen or pencil (in-ceiling models only)
Drill with 3/32-inch drill bit (in-ceiling models only)
Saw to cut hole in ceiling (in-ceiling models only)
Medium Phillips screwdriver (in-ceiling models and pendant surface-mount only)
Drill with hole saw (pendant surface-mount only)
COMPASS TOOL
SAFETY
BRACKET
CONDUIT FITTING
& LOCK NUT
T-RAIL CLIP
Figure 1. Back Box Parts
Pelco Manual C1488M-A (9/98)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 DESCRIPTION
The BB5A Series back boxes are used with the SD5 Series of Spectra™ (Software
Version 3.0) domes and SD5A Series of Spectra II™ domes.The BB5L Series back
boxes are used with the SD5L Series of Spectra™ Lite domes.
The BB5A-F and BB5L-F are for indoor installation in hard ceilings or standard 2' x 2'
(61 x 61 cm) suspended ceilings.
The BB5A-PB (black), BB5A-PG (light gray), and BB5L-PG (light gray) pendant
back boxes are for indoor installation. For outdoor use, the BB5A-PG-E and BB5L-
PG-E include a heater and sun shield.The heater allows operation in temperatures
down to -60°F (-51°C).
2.1 MODELS
BB5A-F
Indoor back box for flush mounting in a ceiling
Black pendant-mount back box
BB5A-PB
BB5A-PG
BB5A-PG-E
BB5L-F
Light gray pendant-mount back box
Same as BB5A-PG except includes heater and sun shield
Indoor back box for flush mounting in a ceiling
Light gray pendant-mount back box
BB5L-PG
BB5L-PG-E
Same as BB5L-PG except includes heater and shield
2.2 CERTIFICATIONS
The products identified below have been tested and certified for agency compli-
ance as noted.
Agency Compliance Certification
Model
CE
FCC
UL
CSA/cUL
BB5A-F
X
X
BB5A-PB
BB5A-PG
BB5A-PG-E
BB5L-F
Pending Pending
Pending Pending
Pending Pending
BB5L-PG
BB5L-PG-E
Applicable CE, FCC, UL, and CSA/cUL directives/standards:
•
93/68/EEC–CE Mark Directive
89/336/EEC, 92/31/EEC–Electromagnetic Compatibility (EMC) Directives
EN 55022: 1984 Class A–Radio-frequency emissions limits
EN 50082-2: 1992–Immunity standard
IEC 801-2: 1984–ESD immunity
IEC 801-3: 1984–Radiated field immunity
IEC 801-4: 1988–Electrical Transients
FCC–47 CFR, Part 15, Subpart B, Class B
UL Listed (DRQH) E119552
•
•
•
cUL Listed (DRQH7)
Additional applicable standards:
•
•
NEMA Type 4 (except -F flush mount models; NEMA Type 1)
IP 66 (except -F flush mount models; NEMA Type 10)
6
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 INSTALLATION FOR IN-CEILING MODELS
This manual covers the installation of the BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E,
BB5L-F, BB5L-PG, and BB5L-PG-E back boxes only. For complete installation and
operating instructions for the SD5 Series of Spectra™ (SoftwareVersion 3.0) domes,
refer to manual C1456M-D; for the SD5A Series of Spectra II™ domes and SD5L
Series of Spectra™ Lite domes, refer to manual C1487M-A.
3.1 CEILING AND BACK BOX PREPARATION
3.1.1 Hard Ceiling
1. Locate the center point where you want to drill a hole in the ceiling.
2. Drill a hole in the ceiling using a 3/32-inch drill bit.
3. Remove the compass tool from the parts bag (refer to Figure 2). Press the
stud of the compass tool into the hole in the ceiling. Insert a pencil in the hole
in the other end of the compass and mark a circle on the ceiling.
CAUTION: Be careful
not to cut outside of the
line.If you do, you may not
be able to install the back
box. Also, the trim ring
may not cover the hole.
4. Carefully cut the circle out of the ceiling.
5. Remove the conduit fitting, lock nut, and safety chain bracket from the parts
bag and attach them to the back box as shown in Figure 3.
Proceed to Section 3.2, WIRING.
ATTACH SAFETY CHAIN HERE
Figure 2. Compass Tool
Figure 3. Conduit Fitting Installation
Pelco Manual C1488M-A (9/98)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.2 Suspended Ceiling
1. Remove the ceiling tile from the ceiling.
2. Locate the center point to drill a hole in the tile.
CAUTION: The ceiling
tile must be capable of
supporting 16 pounds
(7.3 kg) of weight. If the
ceiling tile will not support
this weight, use the op-
tional SD5-P metal panel.
3. Drill a hole in the ceiling tile using a 3/32-inch drill bit.
4. Remove the compass tool from the parts bag (refer to Figure 2). Press the
stud of the compass tool into the hole in the ceiling. Insert a pencil in the hole
in the other end of the compass and mark a circle on the ceiling.
5. Carefully cut the circle out of the ceiling tile.
6. Remove the conduit fitting, lock nut, and safety chain bracket from the parts
bag and attach them to the back box as shown in Figure 3.
7. Refer to Figure 4. Compress the spring clips on the back box with your hands
and push the back box through the hole in the ceiling tile. The spring clips will
spring out when they clear the ceiling tile.
CAUTION: Be careful
not to cut outside of the
line.If you do, you may not
be able to install the back
box. Also, the trim ring
may not cover the hole.
8. Refer to Figure 5. Tighten the screws until the spring clips hold the back box
firmly to the ceiling tile.You will hear a clicking noise when the screws are tight.
Do not install the ceiling tile in the ceiling yet.
Proceed to Section 3.2, WIRING.
3.2 WIRING
Bring wiring to the back box opening in the ceiling. Do not attach the wiring to the
back box.You will do that later.
Refer to Figure 6 for the wiring diagram for Spectra™ (Version 3.0) and Spectra II™,
and to Figure 7 for the Spectra™ Lite.
Wiring is required for power, earth ground, and video.
Refer to Table A for the type of video coaxial cable to use.
NOTE: The dome will stop oper-
ating if the voltage at the dome
drops below 18 VAC. It will turn
back on when the voltage exceeds
18 VAC.
Input power is 24 VAC only. Power consumption is 25 vA per dome for indoor models
and 90 vA for outdoor models. Refer to Table B to determine the size of wire to use.
Use a 24 VAC transformer with the following minimum vA:
30 vA per dome
100 vA per dome
For indoor models (without heater)
For outdoor models (with heater)
Refer to Figure 9 for wiring multiple domes from the same transformer.
Table A. Video Coaxial Cable
Wiring Distances
If you will use a Coaxitron® controller, the control signals to operate the dome drive
will be transmitted over the video coax. The RS-422 control lines are not used.
Cable Type* Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
If you will not use a Coaxitron® controller, use the RS-422 control lines. Use 22-
gauge wire. The distance will be the same as the video coax.
Optional wiring may be provided for alarm inputs (maximum of seven), relay output,
and auxiliary output.
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with
95% braid coverage
Proceed to Section 3.3, BACK BOX INSTALLATION.
8
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
HARD CEILING
OR
CEILING TILE
Figure 4. Installing Back Box
HARD CEILING
OR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
Figure 5. Fastening Back Box
Pelco Manual C1488M-A (9/98)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL
(RS-422)
7
+5 to +24 VDC
EXTERNAL RELAY
(WIRING EXAMPLE)
Figure 6. Wiring Diagram for Spectra™ (Ver. 3.0) and Spectra II™
CONTROL
(RS-422)
Figure 7. Wiring Diagram for Spectra™ Lite
10
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10-
percent voltage drop.(Ten percent is generally the maximum allowable voltage drop
for AC-powered devices.)
Wire Gauge
20
18
16
14
12
10
EXAMPLE: A dome that requires
90 vA and is installed 31 feet (9 m)
from the transformer would require
a minimum wire gauge of 20 AWG.
10
20
25
283 451 716 1142 1811 2880
(86) (137) (218) (348) (551) (877)
141 225 358 571 905 1440
(42) (68) (109) (174) (275) (438)
113 180 286 457 724 1152
NOTE: Distances are calculated in
feet; values in parentheses are
meters.
(34) (55) (87) (139) (220) (351)
94 150 238 380 603 960
(28) (45) (72) (115) (183) (292)
30
40
50
60
70
80
90
70
112 179
285 452 720
(86) (137) (219)
(21) (34) (54)
56
90 143
228 362 576
(69) (110) (175)
(17) (27) (43)
47 75 119
190 301 480
(57) (91) (146)
(14) (22) (36)
40 64 102
163 258 411
(49) (78) (125)
(12) (19) (31)
35 56 89
142 226 360
(43) (68) (109)
(10) (17) (27)
31 50 79
126 201 320
(38) (61) (97)
(9) (15) (24)
100 28
(8)
45
71
114 181 288
(34) (55) (87)
(13) (21)
110 25
(7)
41 65
103 164 261
(31) (49) (79)
(12) (19)
37 59
120 23
(7)
95
150 240
(11) (17)
(28) (45) (73)
130 21
(6)
34 55
87
139 221
(10) (16)
32 51
(26) (42) (67)
140 20
(6)
81 129 205
(9) (15)
(24) (39) (62)
76 120 192
150 18
(5)
30 47
(9) (14)
28 44
(23) (36) (58)
160 17
(5)
71 113 180
(8) (13)
(21) (34) (54)
67 106 169
170 16
(4)
26 42
(7) (12)
25 39
(20) (32) (51)
63 100 160
180 15
(4)
(7) (11)
(19) (30) (48)
190 14
(4)
23 37
60 95 151
(7) (11)
22 35
(18) (28) (46)
57 90 144
200 14
(4)
(6) (10)
(17) (27) (43)
Pelco Manual C1488M-A (9/98)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3 BACK BOX INSTALLATION
1. Suspended Ceiling Only (for hard ceiling, go to step 2) – Install the ceiling
tile with the back box. Attach a T-rail clip on each side of the ceiling tile as
shown in Figure 5.
OPTIONAL PROCEDURE: If
you prefer, you may make the wir-
ing connections inside the back box
before installing the back box in the
ceiling.
The clips for the ceiling tile are supplied with the back box. Attach the clip to
the T-rail. Fasten the L-bracket to the clip with the supplied screw, lock washer
and nut.
To do this, loosen the thumbscrew
inside the back box and open the
hinged door (refer to Figure 8).
Bring the wiring into the back box
through the conduit fitting. Follow
the steps in Section 3.4, “Back Box
Connections,” and then return to
this section.
2. Install a safety chain or cable (not supplied) that will support up to 16 pounds
(7.3 kg). Fasten one end to a support structure in the ceiling. Fasten the other
end to the safety chain bracket (refer to Figure 3) to prevent the back box from
falling.
3. Refer to Figure 8. Loosen the thumbscrew inside the back box and open the
hinged door.
4. Bring the wiring into the back box through the conduit fitting. If the wiring is
inside flexible conduit, connect the conduit to the fitting on the back box.
CAUTION: The ceiling
must be capable of sup-
porting 16 pounds (7.3
kg) of weight. If the ceil-
ing will not support this
weight, provide additional
reinforcement. Also, a
suitable safety chain must
be attached to the back
box to support up to 16
pounds (7.3 kg) in the
event of a ceiling failure.
5. Hard Ceiling Only - Refer to Figure 4. Compress the spring clips on the back
box with your hands and push the back box through the hole in the ceiling.The
spring clips will spring out when they clear the ceiling.Refer to Figure 5.Tighten
the screws until the spring clips hold the back box firmly to the ceiling.You will
hear a clicking noise when the screws are tight.
Proceed to Section 3.4, BACK BOX CONNECTIONS.
THUMBSCREW
Figure 8. Interconnect Door
12
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4 BACK BOX CONNECTIONS
Depending on the type of dome, refer to either Figure 10 or 11 to attach the wiring to the
interconnect circuit board inside the back box. Also refer to Figure 6 or 7 if necessary.
WARNING: Make sure
you wire power to the
outer connectors of the
terminal block and ground
to the middle connector.
Otherwise, you could
damage the dome.
1. Earth Ground - Connect earth ground to the middle connector on the power
connector.
2. Power - Connect 24 VAC from the transformer to the outer terminals on the
power connector. It does not matter which lead goes to which terminal.
If you are wiring more than one dome from the same transformer, it is impor-
tant to wire the power connector in each dome the same way. That is, the
wiring from one side of the transformer must be connected to the same con-
nector on each dome. If you reverse the wiring, the cameras will be out of
phase with each other and may produce what appears to be vertical roll when
switching between cameras. Refer to Figure 9 for a wiring diagram.
3. Video - Connect the coaxial cable to the BNC video connector.
DOME 1
POWER
DOME 2
POWER
EXAMPLE: If each dome
DOME 3
POWER
requires 20 vA, three domes
require a 60 vA transformer.
Figure 9. Transformer Wiring
CONNECTOR
FOR OPTIONAL
TRANSLATOR
HTR/FAN
VIDEO
RS-422
CONTROL
SIGNALS
SUBASSEMBLY
1
RX–
RX+
TX–
TX+
2
DOME DRIVE
CONNECTOR
3
4
5
6
7
GND
NO
COM
NC
AUX 2
GND
AUX 1
FUSE
FAN
24 VAC
MIDDLE
PIN IS
GND
POWER
(24 VAC ONLY)
1.6 A
Figure 10. Interconnect Circuit Board Electrical Connections for
Spectra™ (Ver. 3.0) and Spectra II™
Pelco Manual C1488M-A (9/98)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTOR
FOR OPTIONAL
TRANSLATOR
SUBASSEMBLY
HTR/FAN
VIDEO
RS-422
CONTROL
SIGNALS
RX–
RX+
TX–
TX+
DOME DRIVE
CONNECTOR
FUSE
FAN
24 VAC
MIDDLE
PIN IS
GND
POWER
(24 VAC ONLY)
1.6 A
Figure 11. Interconnect Circuit Board for Spectra™ Lite
4. Control - If you are using a Coaxitron® controller, control signals will be trans-
mitted over the video coax.
If you are using RS-422 (P or D) control signals, connect the control lines from
the controller to the circuit board. Connect the wires as follows:
From controller
To 4-Wire terminal on circuit board
RX-
RX+
TX-
TX-
TX+
RX-
RX+
TX+
5. Heater/Fan - The heater/fan is not used on indoor models.
6. Alarm Inputs - (Spectra™ [Version 3.0] and Spectra II™ Only) If you need
alarm inputs, connect them. The maximum number of alarm inputs is seven.
Refer to Figure 6 for a typical wiring example. Alarm inputs require a ground
signal through a contact closure, such as a switch.
NOTE: Connect only a low volt-
age device to the relay output.
Maximum current rating of the re-
lay contacts is two amperes.
7. AUX 1 - (Spectra™ [Version 3.0] and Spectra II™ Only) An AUX 1 com-
mand from the controller will activate the relay output. If you need the relay, wire
it as required. Refer to Figure 6. The relay contacts are shown when AUX 1 is
inactive.When an AUX 1 command is issued, the relay contacts will reverse and
remain latched until a clear command is issued.
CAUTION: The maxi-
mum output of AUX 2 is
150 mA. If you connect a
device that draws more
current, you could destroy
the output transistor. The
output is intended to drive
logic circuits or low-current
devices. If higher current
is required, connect the
output to a relay.
8. AUX 2 - (Spectra™ [Version 3.0] and Spectra II™ Only) An AUX 2 command
from the controller will place a ground at the output of AUX 2 to operate the device
connected to it.The output will remain latched until a clear command is issued. If
you need the AUX 2 output, wire it as required. Refer to Figure 6 for typical wiring
examples.The AUX 2 output is an open collector transistor driver which is capable
of passing a maximum of 150 mA at 32 VDC. It is capable of driving TTL logic
circuits or low-current reed relays.If you use an external relay, make sure that both
the supply voltage and the current requirements are well below the maximum of
32 VDC and 150 mA. Exceeding these values will cause permanent damage to
the dome. If you are not familiar with open collector drive requirements, contact
Pelco technical support for assistance.
CAUTION: Leave ad-
equate slack in the wiring
to permit the door to open
without pulling on the con-
nectors.
9. Close the door and tighten the thumbscrew securely.
10. Turn on power to the back box. The red LED on the interconnect door should
light. The fan will not operate until a dome drive is installed.
If the LED does not light, correct the trouble before proceeding. Refer to Sec-
tion 5.0, TROUBLESHOOTING.
14
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 INSTALLATION FOR PENDANT MODELS
4.1 PENDANT-MOUNT INSTALLATION
1. Install the pendant dome mount. Refer to the instructions provided with the
mount. If the mount is outdoors, make sure it is properly sealed to keep mois-
ture out.
2. Bring the wiring for the dome through the mount. Refer to Section 3.2, WIR-
ING.
3. Refer to Figure 8. Loosen the thumbscrew inside the back box and open the
hinged door.
NOTE: If outdoors, apply Duct
Seal inside the pipe portion of the
back box to prevent moisture or
cold air inside the mount from en-
tering the unit and causing conden-
sation on the dome. Duct Seal can
be purchased through local elec-
trical supply houses.
4. Screw the back box into the mount as far as possible and bring the wiring into
the back box.If outdoors, apply the provided pipe sealant to the threads on the
back box.
5. Attach the wiring to the back box. Refer to Section 3.4, BACK BOX CONNEC-
TIONS. Hanging down from the back box is a short cable (the trim ring leash)
and a heater connector with two wires (outdoor units only). The leash and
heater wiring will be connected when the lower dome is installed.
4.2 SURFACE-MOUNT INSTALLATION
1. Use a hole saw to drill a hole in the ceiling where you want to hang the pen-
dant dome.
2. Bring the wiring for the dome to the opening. Refer to Section 3.2, WIRING.
3. Refer to Figure 8. Loosen the thumbscrew inside the back box and open the
hinged door.
4. Remove the gasket and the top mount from the back box by taking out the
three screws and lock washers.
5. Attach the back box to the ceiling using #8 hardware (not supplied). Reattach
the cable (trim ring leash) that was attached to one of the screws you removed
in step 4.
6. Attach the wiring to the back box. Refer to Section 3.4, BACK BOX CONNEC-
TIONS. Hanging down from the back box is a short cable (the trim ring leash)
and a heater connector with two wires (outdoor units only). The leash and
heater wiring will be connected when the lower dome is installed.
Pelco Manual C1488M-A (9/98)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 TROUBLESHOOTING
Symptom: LED does not light.
If the red power LED on the door of the interconnect circuit board in the back box
does not light:
1. Turn off power.
2. Open the door to the interconnect circuit board and check the fuse. Refer to
Figure 10 for the location of the fuse. If the fuse is bad, replace it. To order a
replacement fuse from Pelco, specify the part number FUS1.6-5X20FAST.This
is a 1.6-ampere fuse, 5 x 20 mm, fast blow.
3. If the fuse is good, turn on power and use a voltmeter to check if 24 VAC is
getting to the power connector on the interconnect circuit board. Refer to Fig-
ure 10 for the location of the AC power connector.
4. If there is 24 VAC to the power connector, turn off the power and return the
back box electronic assembly to the factory for repair.
To remove the back box electronic assembly:
a. Turn off power.
b. Open the interconnect door and disconnect all wiring to the back box.
c. Use an 11/32-inch socket driver to remove the three 8-32 washers and
nuts that hold the electronic assembly to the back box.When the screws
are removed, the interconnect back box receptacle will drop down. It may
be necessary to move the open interconnect door past 90° vertical to-
ward the side of the back box to release the door from built-in grounding
strip (and free the interconnect back box receptacle).
d. Remove the interconnect back box receptacle with the electronic compo-
nents from the back box.
5.1 SERVICE MANUAL
If you need to service your unit, obtain a service manual in on of the following ways:
•
•
•
C1455SM.
Call Pelco’s DataFAX service at 1-209-292-0435 and request document
214558.
Contact Pelco’s Literature Department and request service manual C1455SM.
16
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 SPECIFICATIONS
MECHANICAL
Construction
Back box:
Aluminum
Cable Entry
In-Ceiling:
Pendant:
.75" (1.91 cm) conduit fitting
Through 1.5" (3.81 cm) NPT pendant mount
Dimensions:
See Figure 12
ELECTRICAL
Input Voltage:
18-30 VAC, 24 VAC nominal
25 vA
Input Power
In-ceiling:
Indoor pendant: 25 vA
Outdoor pendant: 90 vA
Fuse:
1.6 A
Relay
Contacts (AUX 1)*
Type:
Form C
Voltage:
Current:
Low voltage (< 40 v)
2 A maximum
AUX 2 Output*
Type:
Voltage:
Open collector transistor output
32 VDC maximum
Current:
150 mA maximum
* Applies to Spectra™ (Version 3.0) and Spectra II™ only.
GENERAL
Environment
In-Ceiling:
Pendant:
Indoor only
Indoor/outdoor
Operating Range
In-Ceiling:
Pendant
32° to 122°F (0° to 50°C)
Without heater: 32° to 122°F (0° to 50°C)
With Heater*: -60° to 122°F (-51.11° to 50°C)
continuous operation; minimal icing
-50° to 122°F (-45.56° to 50°C)
continuous operation; prevents icing
-40° to 122°F (-40° to 50°C) continuous operation; de-ices
0.1" (2.5 mm) within 3 hours after power-up
Weight
In-Ceiling
Unit
Shipping
Back Box
Pendant
2.6 lbs (1.18 kg)
4.0 lbs (1.81 kg)
Back Box†
2.85 lbs (1.28 kg) 5.0 lbs (2.27 kg)
* Assumes no wind chill factor; for detailed test conditions, contact Pelco.
† Add 1.25 lbs (.57 kg) for outdoor models with sun shield and heater
(Design and product specifications subject to change without notice.)
Pelco Manual C1488M-A (9/98)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
TOP PORTION OF BACK BOX
DOME IS SECURED
IS REMOVABLE FOR SURFACE TO CEILING BY
MOUNT APPLICATIONS
MOUNTING BRACKET
7.25 (18.13)
6.60 (16.76)
8.52
(21.64)
5.25
(13.34)
6.75
(17.15)
10.90
27.69
5.83
(14.80)
3.25
(8.26)
5.90 (14.99)
8.25 (20.96)
5.90
(14.99)
In-Ceiling Dome
Pendant Dome
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS, ALL OTHERS ARE INCHES.
Figure 12. SD5 Series Dimension Drawing
18
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Pelco Manual C1488M-A (9/98)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment. Excep-
tions to this warranty are as noted below:
•
•
•
Three years on Genex™ Series (multiplexers, server, and keyboard).
Two years on all standard motorized and fixed focal length lenses.
Two years on Legacy®, Intercept®, PV1000 Series, CM6700/CM8500/CM9500/
CM9750/CM9760 Matrix, Spectra™, DF5 Series and DF8 Fixed Dome products.
Two years on WW5700 series window wiper (excluding wiper blades).
Two years on cameras.
•
•
•
Six months on all pan and tilts, scanners or preset lenses used in continuous
motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warranty all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to
Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration,
normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss result-
ing from the specific use or application made of the Products. Pelco’s liability for any
claim, whether based on breach of contract, negligence, infringement of any rights
of any party or product liability, relating to the Products shall not exceed the price
paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any
special, incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may
also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(209) 292-1981 to obtain a Repair Authorization number (RA), and provide the
following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under
the warranty conditions stated above, please include a written explanation with the
product when returned.
Ship freight prepaid to:
Pelco
300 West Pontiac Way
Clovis, CA 93612-5699
Method of return shipment shall be the same or equal to the method by which the
item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the
factory at (800) 289-9100 or (209) 292-1981 to obtain an authorization number (CA
number if returned for credit, and RA number if returned for repair). Goods returned
for repair or credit should be clearly identified with the assigned CA/RA number and
freight should be prepaid. All merchandise returned for credit may be subject to a
20% restocking and refurbishing charge.
®Pelco and the Pelco logo are
registered trademarks of Pelco.
©Copyright 1998, Pelco. All rights
reserved.
Ship freight prepaid to:
Pelco
300 West Pontiac Way
Clovis, CA 93612-5699
20
Pelco Manual C1488M-A (9/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
|