Operating and Installation
Instructions
Ventilation System
DA 5321 W
DA 5381 W
DA 5391 W
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 901 910
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
,WARNING
READ AND SAVE THESE
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
INSTRUCTIONS
Keep these instructions in a safe
place and pass them on to any future
user.
OBSERVE THE FOLLOWING:
a) Use this appliance only in the
~
manner intended by the manufacturer.
Read these instructions carefully
before installing or using the
Ventilation System.
If you have questions, contact Miele.
b) Before servicing or cleaning the
~
appliance, switch power off at the
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally. If
the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
This appliance is intended for
~
residential use only. Use the appliance
only for its intended purpose.
This appliance complies with current
~
safety requirements. Improper use of
the appliance can lead to personal
injury and material damage.
c) Be certain your appliance is
~
properly installed and grounded by a
,CAUTION
qualified technician.
For General Ventilating Use
Only. Do Not Use To Exhaust
Hazardous Or Explosive
Materials And Vapors.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician.
This appliance is designed to vent
~
cooking smoke and odors only.
This appliance is suitable for
~
installation above gas or electric
cooking surfaces.
This appliance is not intended for
~
outdoor use.
This appliance must not be used in
~
a non-stationary location (e.g. on a
ship).
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
d) Before connecting the appliance
Use
~
to the power supply make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply.
,WARNING
TO REDUCE THE RISK OF A
COOKTOP GREASE FIRE:
This data must correspond to prevent
appliance damage. If in doubt consult a
qualified electrician.
a) Never leave surface units
~
unattended at high settings. Boilovers
cause smoking and greasy spillovers
may ignite. Heat oils slowly on low or
medium settings.
e) Installation work and repairs
~
should only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous.
b) Always turn the hood on when
~
cooking at a high heat.
c) Clean the ventilation hood
~
f) Only open the housing as
frequently. Grease should not be
allowed to accumulate on the fan or
filter.
~
described in the enclosed "Installation
diagram" and in the "Cleaning and care"
section of this manual. Under no
circumstances should any other parts
of the housing be opened. Tampering
with electrical connections or
d) Use the proper pan size. Always
~
use cookware appropriate for the size
of the cooking area.
components and mechanical parts is
highly dangerous to the user and can
cause operation faults.
e) Do not flambé or grill with an
~
open flame beneath the hood.
Flames could be drawn up into the
hood by the suction and the grease
filters may catch fire.
g) Before discarding an old
~
appliance, disconnect it from the power
supply and remove the power cord to
prevent hazards.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
,WARNING
Do not allow children to play with or
~
operate the appliance or its controls.
Supervise its use by the elderly or
infirm.
TO REDUCE THE RISK OF
INJURY TO PERSONS IN THE
EVENT OF A COOKTOP
GREASE FIRE, OBSERVE THE
FOLLOWING*:
Always turn on the hood when using
~
the cooktop to prevent damage from
condensation.
a) SMOTHER FLAMES with a close
~
fitting lid, cookie sheet, or metal tray
then turn off the burner.
Never operate gas burners without
~
cookware. Turn the burner off when not
in use. Adjust the burner so that the
flames do not extend beneath the
cookware. Do not overheat the
cookware, e.g. when using a wok. The
hood can be damaged due to
excessive heat from the burners and
the cookware.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
b) NEVER PICK UP A FLAMING
~
PAN - You may be burned.
c) DO NOT USE WATER, including
Do not use the hood without the
~
grease filters in place.
~
wet dishcloths or towels - a violent
steam explosion will result.
Do not use a steam cleaner to clean
~
d) Use a fire extinguisher ONLY if:
the hood. Steam could penetrate
electrical components and cause a
short circuit.
~
1) You have a class ABC
extinguisher, and you know how to
operate it.
2) The fire is small and contained in
the area where it started.
3) The fire department is being
called.
4)You can fight the fire with your
back to an exit.
*
Based on "Kitchen Firesafety Tips"
published by NAFTA
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Installation
g) Do not install this hood over
~
cooktops that burn solid fuel.
,WARNING
h) Provided a larger distance is not
~
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
given by the manufacturer of the
cooktop, follow the minimum safety
distances between a cooktop and the
bottom of the hood given in the
"Appliance dimensions" section of this
manual.
a) Installation work and electrical
~
wiring must be done by qualified
person(s) in accordance with all
applicable codes and standards,
including fire-rated construction.
If local building codes require a greater
safety distance, follow their
requirement.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
b) Sufficient air is needed for
~
combustion and exhausting of gases
through the flue (chimney of fuel
burning equipment to prevent back
drafting. Follow the heating equipment
manufacturer’s guideline and safety
standards such as those published by
the National Fire Protection Association
(NFPA) and the American Society for
Heating, Refrigeration and Air
i) Never connect an exhaust hood to
~
an active chimney, dryer vent, vent flue,
or room ventilating ductwork.
j) Seek professional advice before
~
connecting an exhaust hood vent to an
existing, inactive chimney or vent flue.
Conditioning Engineers (ASHRAE), and
the local code authorities.
k) Any fittings, sealant, or materials
~
used to install the ductwork must be
made of approved non-flammable
materials.
c) When cutting or drilling into the
~
wall or ceiling, do not damage electrical
wiring and other hidden utilities.
d) Ducted hoods must always be
~
vented to the outdoors.
,WARNING
TO REDUCE THE RISK OF
FIRE USE ONLY METAL
DUCTWORK.
e) Do not use this hood with any
~
solid-state speed control device.
f) Do not use an extension cord to
~
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance,
(e.g. danger of overheating).
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional description
The hood offers two modes of
operation:
Air extraction
Recirculation mode
The air is drawn in and cleaned by the
grease filters and directed outside.
Air is drawn through the grease filters
and an active charcoal filter. The
filtered air is then recirculated back into
the kitchen through a vent at the top of
the hood’s chimney.
The hood comes equipped with a
non-return flap. This flap automatically
closes when the hood is turned off so
that no exchange of outside air and
room air can occur. When the hood is
turned on, the air pressure of the
exhaust fan automatically opens the
flap blowing the inside air and cooking
odors outside.
The recirculation mode requires an
install kit and charcoal filter which are
optional accessories.
Before using the hood in
recirculation mode, ensure that the
active charcoal filter is in place, see
"Cleaning and care".
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the Ventilation System
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the Ventilation System
a Chimney extension
b Chimney
m Grease filter button
The indicator next to the grease filter
button lights when the grease filters
need to be cleaned. This button is also
used:
c Canopy
– to reset the grease filter timer after
cleaning the grease filters (see
"Cleaning and Care").
d Charcoal filter
(optional accessory)
– to show how long the grease filters
have been in use (see "Operation/
Filter timers").
e Grease filter
f Recirculation vent
g Control panel
h Overhead lighting
i Light button
– to change the number of hours
counted by the grease filter timer
(see "Operation/Reprogramming the
timers").
n Charcoal filter button
The indicator next to the charcoal filter
button lights when the charcoal filter
needs to be replaced.
This button turns the light on and off
and also dims the light.
The lighting can be used independently
from the fan.
This button is also used:
– to reset the charcoal filter timer after
changing the filter (see "Cleaning
and care").
j On/Off button
– to show how long the charcoal filter
has been in use (see "Operation/
Filter timers").
k Fan power selection
Four fan speed selection
– to change the number of hours
counted by the charcoal filter timer
(see "Operation/Reprogramming the
timers").
l Delayed shut down
This button activates the Delayed Shut
Down feature. The fan can be set to
turn off automatically after either 5 or 15
minutes.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning on the fan
Automatically switching back the
Intensive power level
The intensive level "4" can be
programmed to automatically switch
back to level "3" after 10 minutes.
^ Press the On/Off button.
^ Turn the fan and the lights off.
Selecting the power level
^ Press and hold the Delayed Shut
down button for 10 secs. The first
indicator of the fan power levels
lights.
^ Use the "–/+" controls to select the
desired power level.
+ = increases the fan speed
^ Press the following buttons one after
– = decreases the fan speed
another,
Level "1" to "3" are usually sufficient for
normal cooking.
Intensive setting
Level "4" should only be used for short
periods of time when frying or cooking
food with a strong aroma.
– light,
– the "-" button, and
– the light button again.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
If the power level indicators flash the
automatic switch back is not activated.
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
^ To activate the automatic switch back
press the "+" button.
The power level indicators light.
There will also be a slight decrease in
airflow for hoods operated in
recirculation mode due to the active
charcoal filter.
^ To deactivate the automatic switch
back press the "–" button.
^ To save the setting press the
Delayed Shut down button.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Delayed Shut Down
Turning off the fan
If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be
selected to allow the hood to continue
running for either 5 or 15 minutes.
^ Press the On/Off button to turn the
fan off.
The indicator will go out.
Automatic Safety Shut Off
^ Press the Delayed Shut Down button
The fan will turn off automatically
10 hours after the last button was
pressed. The lighting however will
remain on.
while the fan is still running.
Press once = 5 minute delay
(left indicator lights)
Press twice = 15 minute delay
(right indicator lights)
To cancel the Delayed Shut Down
feature press the button again.
^ Press the On/Off button to turn the
fan back on again.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning the lighting On/Off
Dimming the lighting
The overhead lighting can be turned on The brightness of the lighting can be
and off independently from the fan.
adjusted.
^ While the lighting is turned on, press
the light button.
The lighting will dim until the button is
released.
^ Press the light button briefly to turn
^ If the button is pressed again, the
lighting will brighten until the button is
released.
on the lighting.
The light button indicator illuminates.
If the button is pressed continuously,
the light will cycle between bright and
dark.
^ Press the light button briefly again to
turn off the lighting.
The light button indicator will go out.
^ Press the light button again to turn off
the lighting.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Filter timers
Checking the filter timers
^ Press the On/Off button to turn the
Grease filters
fan on.
A timer monitors the hours of fan
operation. The indicator for the grease
filter will light after 30 hours of
operation. The grease filters must then
be cleaned.
^ Press and hold the grease or
charcoal filter button.
After the grease filters have been
cleaned and put back in place, the
grease filter timer must be reset.
The number of flashing "–/+" indicators
show the percentage of programmed
hours that have been used.
^ To do this, press the grease filter
button for approx. 3 seconds.
The indicator will go out.
Charcoal filter
1 indicator = less than 25 %
2 indicators = less than 50 %
3 indicators = less than 75 %
4 indicators = less than 100 %
Recirculation mode only
The timer for the charcoal filter is not
preset. Please program this timer, see
"Operation - Reprogramming the
charcoal filter timer".
This information will remain stored in
memory in the event of a power failure.
The charcoal filter indicator will light
once the selected time has elapsed.
The charcoal filter must then be
replaced and the charcoal filter timer
reset.
^ To do this, press the charcoal filter
button for approx. 3 seconds.
The indicator will go out.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the timers
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40, or 50 hours.
The lit indicator shows the programmed
time:
– A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally to prevent grease
which has accumulated over a long
period of time from hardening on the
filters making cleaning more difficult.
^ Use the "–/+" button to select the
desired time.
Reprogramming the grease filter
timer
^ Save the selection by pressing the
grease filter button.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
^ Press the On/Off button to turn off the
fan.
^ Press the Delayed Shut Down and
grease filter buttons at the same time.
The indicator for the grease filter and
one of the "–/+" indicators will flash.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the charcoal filter
timer
The active charcoal filter can only be
used in recirculation mode and cannot
be used to exhaust fumes.
The lit indicator shows the programmed
time:
The charcoal filter timer is not preset.
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
Before using the hood in recirculation
mode, the charcoal filter timer must be
programmed.
^ Use the "–/+" button to select the
desired time.
^ Save the selection by pressing the
^ Turn off the fan using the On/Off
charcoal filter button.
button.
^ Press the Delayed Shut Down and
charcoal filter buttons at the same
time.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
The indicator for the charcoal filter and
one of the "–/+" indicators will flash.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
,WARNING
Avoid:
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
– cleaning agents containing soda,
acids or chlorides,
– abrasive cleaning agents
e.g. powder or cream cleansers,
– abrasive sponges, e.g. pot scourers
or sponges which have been
previously used with abrasive
cleaning agents.
Before cleaning or servicing the
hood, disconnect it from the power
supply, see "Important Safety
Instructions".
These will damage the surface.
The following instructions for cleaning
"Stainless steel" surfaces and "Stainless
steel colored controls" should be
followed in addition to the general
"Cleaning the casing" instructions.
,The halogen bulbs are very hot
when in use. They stay hot for some
time after turned off. Use caution,
danger of burns.
Wet cleaning the hot bulbs will
cause damage.
Stainless steel
Wait a few minutes after turning
them off before cleaning.
Stainless steel surfaces can be cleaned
using a non-abrasive stainless steel
cleaner.
Cleaning the casing
To help prevent resoiling, a conditioner
for stainless steel can be applied.
Never use abrasive cleaners,
scouring pads, steel wool or caustic
(oven) cleaners on the hood. They
will damage the surface.
Stainless steel colored controls
These controls may become dis-
colored or damaged if not cleaned
regularly.
^ All external surfaces and controls can
be cleaned with a mild solution of
warm water and liquid dish soap
applied with a soft sponge.
Do not use a stainless steel cleaner
on these controls.
^ Wipe dry using a soft cloth.
Do not use too much water when
cleaning the controls. Water could
penetrate the electronics and cause
damage.
^ Glass surfaces can be cleaned using
a glass cleaner.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Grease filters
^ In a dishwasher: place the filter
vertically in the lower basket, making
sure that the spray arm is not
blocked.
The reusable metal grease filters
remove solid particles from the vented
kitchen air (grease, dust, etc).
Use a wash program with a max.
temperature of 150°F (65°C). In a
Miele dishwasher use the "Normal"
program.
Use the recommended amount of
dishwasher detergent. Overuse could
destroy the filter.
The grease filters should be cleaned
every 3 - 4 weeks or when the grease
filter indicator lights.
Depending on the detergent,
cleaning the grease filters in a
dishwasher may cause permanent
discoloration of the filter surface.
Performance of the filter will not be
affected by this discoloration.
,A dirty filter is a fire hazard.
^ After cleaning, the filters can be
placed on a towel to air dry.
^ While the filters are removed, clean
any dirt or grease from the filter
casing to prevent the risk of fire.
When putting the grease filters back
make sure that the locking clips are
visibly facing the cooking surface.
^ To remove the grease filters pull the
locking clips, 1, forward. Lower the
filter 45°, 2, unhook it at the rear, 3,
and take it out. Support the grease
filter so that it does not fall onto the
cooktop.
If the filters are incorrectly installed,
insert a small screwdriver into the slit
along its edge to disengage it from the
casing.
^ After returning the grease filters,
press and hold the grease filter
button for 3 seconds to reset the
timer. The indicator light will go out.
Cleaning the grease filter
^ By hand: use a scrub brush with a
solution of warm water and mild
detergent.
^ If the grease filters are cleaned
before the grease filter timer has
reached its maximum, press the
grease filter button for 6 seconds to
reset the counter to zero.
Do not use the pure detergent,
aggressive all purpose cleaners,
oven sprays, abrasive cleaning
agents or limescale removers. They
could destroy the filter.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Active charcoal filter
In recirculation mode an active
charcoal filter must be used in addition
to the grease filters. It is designed to
absorb cooking odors.
The active charcoal filter will be
replaced in the canopy above the
grease filters.
Replacement active charcoal filters
can be ordered from Miele.
^ Insert the charcoal filter.
Before using:
^ Remove the grease filters to access
the charcoal filter. See "Cleaning and
Care".
^ Program the charcoal filter timer, see
"Operation / Reprogramming the
charcoal filter timer".
Replace the active charcoal filter when
the charcoal filter indicator lights, at
least every 6 months or when they no
longer absorb odors efficiently.
^ After replacing the charcoal filter,
press and hold the charcoal filter
button for about 3 seconds to reset
the charcoal filter timer.
The indicator light will go out.
If the charcoal filter is replaced before
the timer has reached its maximum, the
charcoal filter button should be pressed
for 6 seconds to reset the counter to
zero.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Changing the light bulbs
,WARNING
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Before changing the light bulbs,
disconnect the hood from the power
supply, see "Important Safety
Instructions".
When in use halogen bulbs become
extremely hot, and can burn your
hands. Do not attempt to change the
bulbs until they have had sufficient
time to cool.
^ To change the halogen bulb, first
gently press the light cover. The
cover will open and can now be
flipped down.
Do not touch the bulb surface.
Fingerprints or body oils deposited
on the bulb will decrease its life.
Please follow the manufacturer’s
instructions.
^ Pull the halogen bulb from its socket,
then insert a new bulb (type 12V,
20W, G4).
^ Flip the light cover back up, making
sure it clicks into place.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
After Sales Service
Repairs
MieleCare
In the event of a fault which you cannot
easily fix yourself, please contact the
Miele Technical Service Department.
(USA only)
MieleCare, our Extended Service
Contract program, gives you the
assurance of knowing that your
^ When contacting the Technical
Service Department, please quote
the model and serial number of your
appliance.
appliance investment is covered by
5 years of worry free ownership.
MieleCare is the only Extended Service
Contract in the industry that guarantees
repairs by a Miele Authorized Service
Provider using genuine Miele parts.
Only genuine Miele parts installed by
factory trained professionals can
guarantee the safety, reliability, and
longevity of your Miele appliance.
These are shown on the data plate
which is visible when the grease filters
are removed.
Please note that unless expressly
approved in writing by Miele’s Service
department, Extended Service
Contracts offered by other providers for
Miele products will not be recognized
by Miele. Our goal is to prevent
unauthorized (and untrained) service
personnel from working on your Miele
products, possibly doing further
damage to them, you and/or your
home.
To learn more about MieleCare
Extended Service Contracts, please
contact your appliance dealer or visit
us online at:
21
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Read these instructions and the "Important Safety Instructions" before installing
this ventilation system.
The installation steps are described in the enclosed "Installation Diagram".
Leave these instructions with the appliance for the consumer/user.
Information is subject to change. Please refer to our website to obtain the most
current product specification, technical & warranty information.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Caring for the environment
Disposal of packing material
Disposal of an old appliance
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling center about the
possibility of recycling these materials.
Before discarding an old appliance,
disconnect it from the electrical
,DANGER
Ensure that any plastic wrappings,
bags, etc., are disposed of safely
and kept out of the reach of babies
and young children. Danger of
suffocation!
supply and cut off the power cord to
prevent it from becoming a hazard.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
1) Air extraction mode
4) and 5) Installation area
Wall/ceiling area respectively for vent
hole and outlet installation.
2) Recirculation mode
3) Air extraction vent installed upwards
For recirculation mode only 4)
and only outlet installation.
Vent hole 6" (150 mm) with reducing
collar 5" (125 mm).
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
Cut out area in wall or ceiling for Standard unit height (H):
entrance of 6" (150 mm)
ductwork or 5" (125 mm)
Air Extraction . . . . . . . . 29 5/16" - 41 9/16"
. . . . . . . . . . . . . . . . . . (745 - 1055 mm)
Recirculation. . . . . . . . 34 7/16" - 46 11/16"
. . . . . . . . . . . . . . . . . . (875 - 1185 mm)
ductwork with a reducing collar.
The installation procedure differs
depending on the model and venting
method.
To fit the lower chimney section, the
distance between the top of the
chimney and the ceiling must be at
least 7/8" (20 mm).
Before beginning the installation:
^ Read all instructions.
^ Determine height (S), regarding the
user’s body height, i.e. a comfortable
height for the user.
However, the greater the distance the
less effectively cooking odors are
drawn in.
^ If the hood is fitted flush to the
ceiling, regard the possible unit
height when selecting the installation
height.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
Distance between cooktop and hood (S)
Do not install this exhaust hood over cooktops burning solid fuel.
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood:
Miele Cooktops
Non-Miele
Cooktops
Electric Cooktops
24" (610 mm)
26" (660 mm)
Electric Barbeques and Fryers
Multiburner Gas cooktops
< 43,000 BTU (12.6 KW)
26" (660 mm)
30" (760 mm)
and no burner > 15,000 BTU (4.5 KW)
Single burner (Wok) < 20,500 BTU (6 KW)
All other gas cooktops
26" (660 mm)
30" (760 mm)
30" (760 mm)
– If several gas surfaces are installed under the hood, the total output must be
considered when determining the minimum safety distance.
– Be sure to follow the minimum safety distances given by the gas cooktop
manufacturer to easily flammable materials e.g. upper cabinets.
– If local building codes require a greater safety distance, follow their
requirement.
– If there is more than one appliance beneath the hood and they have different
minimum safety distances always select the greater distance.
See "Important Safety Instructions" for further information.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Plywood backing
^ Find the studs to the left and right of
the mounting location by tapping the
wall or using a stud finder.
The majority of the weight of the
installed ventilation system will be
supported by the lower retaining
plate. It must be firmly attached to
the stud framing behind the drywall.
If studs are not available in the
required locations, a plywood
backing (min. ½" (13 mm) thick)
spanning at least two studs must be
installed. Failure to adequately
support the weight as stated may
result in the ventilation system falling
off the wall, causing personal injury
and property damage.
^ Mark a vertical cutting line along the
center of each stud.
,CAUTION
When cutting or drilling into the wall
or ceiling, do not damage electrical
wiring and other hidden utilities.
^ Remove the drywall between the
cutting lines and replace it with
plywood of a matching thickness
(min. ½" (13 mm) thick). Tape the
joints and refinish the wall.
(If plywood backing is not needed,
proceed to the included "Installation
diagram".)
^ Proceed to the enclosed "Installation
diagram" to complete the installation.
To install a plywood backing
^ Determine and mark the location of
the retaining plate for the canopy as
outlined on the "Installation diagram".
^ Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of
the retaining plate.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
a 3 protective shields to prevent
scratches to the chimney during
installation.
8 large headed screws 5 x 40 mm
b 1 vent collar
for use with 6" (150 mm) exhaust
ducting
for securing the retaining plates and the
canopy.
(S8 wall anchors included in the
c 1 reducing collar for use with 5"
(125 mm) exhaust ducting.
packaging are not for use in USA / CDN.)
d Telescopic retaining plate secures
the chimney extension
e Installation kit for recirculation
mode contains diverter, hose and hose motor assembly.
2 M 6 locking nuts for securing the
clips (optional accessory)
,CAUTION
2 screws 3.9 x 7.5 mm for securing the
To avoid risk of hand or other injury,
avoid contact with sharp edges
during the assembly and installation
process.
chimney.
1 lever for dismantling the chimney
Installation diagram
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Protective film
Dismantling
The casing is covered with a protective If the hood needs to be disassembled,
film to prevent scratching during
transport.
follow the instructions on the
"Installation diagram" in the reverse
order.
^ Peel off the film before installing the
casing parts.
A lever is enclosed for easier removal
of the chimney extension.
^ After removing the screws from the
chimney, slide the lever between the
chimney and the chimney extension
and gently apply pressure to ease
the chimney from its hooks.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Exhaust ducting and connections
,WARNING
Use smooth or flexible pipwork made
from approved non-flammable
materials for exhaust ducting.
Danger of toxic fumes.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
To reduce the risk of fire and to
properly exhaust air, the exhaust
gases extracted by the hood
should be vented outside of the
building only.
To achieve the most efficient air
extraction and quietest noise levels,
consider the following:
– The diameter of the ductwork should
not be less than 6" (150 mm).
– If flat ducting is used, the cross
section must not be smaller than the
cross section of the ventilation
exhaust.
Do not vent exhaust air into
spaces within walls or ceilings or
in attics, crawl spaces or garages.
– The ducting should be as short and
straight as possible.
– Use ductwork with a wide raduis.
To reduce the risk of fire, only use
metal ductwork.
– The exhaust duct must not be bent
or compressed.
Please read and follow the
– Make sure all connections are
secure.
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
– Where the ductwork is horizontal, it
must slope away from the hood at
least 1/8" per foot (1 cm per meter) to
prevent condensation dripping into
the appliance.
– If the exhaust is ducted through an
outside wall, a Telescopic Wall Vent
can be used.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Condensate trap
optional accessory
– If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and 6"
(150 mm) in diameter.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
^ When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical connection
,WARNING
Grounding Instructions
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
This appliance must be grounded. In
the event of an electrical short circuit,
grounding reduces the risk of electric
shock by providing a path of least
resistance. This appliance is equipped
with a cord having a grounding wire
with a grounding plug. The plug must
be plugged into an outlet that is
All electrical work should be
performed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA 70)
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
properly installed and grounded.
WARNING - Improper grounding can
result in a risk of electric shock.
If there is any doubt, have the electrical
system of the house checked by a
qualified electrician.
Ensure that power to the appliance
is off while installation or repair work
is performed.
Do not use an extension cord. If the
power supply cord is too short, have a
qualified electrician install an outlet
near the appliance.
^ Verify that the voltage, load and
circuit rating information found on the
data plate (located behind the
grease filters), match the household
electrical supply before installing the
hood.
Important
The hood comes equipped with a 4 ft
(1.2 m) power cord with a NEMA 5-15
molded plug for connection to a
^ Use only with ventilation hood
cord-connection kits that have been
investigated and found acceptable
for use with this model hood.
120 VAC, 60 Hz, 15 A power outlet.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or contact Miele’s
Technical Service Department.
,WARNING:
THIS APPLIANCE MUST BE
GROUNDED
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical data
Maximum load
DA 5381 W / DA 5391 W . . . . . . . 430 W
DA 5321 W . . . . . . . . . . . . . . . . . 450 W
Overhead lighting
DA 5381 W / DA 5391 W . . . . . 4 x 20 W
DA 5321 W. . . . . . . . . . . . . . . . 5 x 20 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit rating. . . . . . . . . . . . . . . . . . 15 A
Weight
DA 5381W . . . . . . . . . . . . . 75 lb (34 kg)
DA 5391W . . . . . . . . . . . 77.2 lb (35 kg)
DA 5321W . . . . . . . . . . 82.7 lb (37.5 kg)
36
Download from Www.Somanuals.com. All Manuals Search And Download.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Alteration rights reserved / 1711
M.-Nr. 07 901 910 / 01
INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST
CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
Download from Www.Somanuals.com. All Manuals Search And Download.
|