1. REMOTE CONTROL DETAIL
2. PROGRAM REMOTE CONTROL INTO CONSOLE
DF-41/EC
DF-42/EC
CONTROLS
HOME AUTOMATION
OUTPUT
START IN
OFF MODE
SEND SIGNAL
FROM REMOTE
ARMS &
DISARMS
CONSOLE
ENTER YOUR
SECRET CODE
PRESS
LEARN UNUSED SENSOR
NUMBER
ENTER AN
KEYCHAIN
REMOTE
LEARN BUTTON
CONTROL
For Use With DF-16/EC
Security Console
Operation
Instructions
1
TWO BUTTON
REMOTE CONTROL
PRESS BUTTON
TO SEND SIGNAL
(EITHER BUTTON
ON TWO BUTTON
REMOTE)
HOLD OFF BUTTON
FOR 3 SECONDS WHEN
FINISHED TO EXIT
LEARN MODE
ONE BUTTON
REMOTE CONTROL
(760) 438-7000 • FAX (760) 438-7043
3. TEST REMOTE CONTROL
4. REPLACING BATTERIES
5. REPLACING BATTERIES
PRESS ONCE TO ARM CONSOLE TO AWAY MODE
PRESS AGAIN TO DISARM CONSOLE TO OFF MODE
REMOVE TWO
WARNING:
HOLD BOARD BY
HOLD CASE TOGETHER
AND FLIP OVER
CASE SCREWS
CAREFULLY
ONE CHIRP FOR ARM
TWO CHIRPS FOR DISARM
REMOVE THE
CIRCUIT BOARD
EDGES ONLY
ONE
BUTTON
REMOTE
PRESS FOR HOME AUTOMATION ON
PRESS AGAIN FOR H/A OFF
BOARD
ALIGNMENT
POSTS
CAREFULLY
LIFT TOP OF
CASE OFF
ONE BING FOR H/A ON
ONE BING FOR H/A OFF
NOTE BATTERY
LOCATIONS
REPLACE THE REMOTE CONTROL BATTERIES WHEN
THE UNIT ONLY WORKS CLOSE TO THE CONSOLE OR IF
IT STOPS WORKING ALTOGETHER
TWO
BUTTON
REMOTE
NOTE: PRESSING BOTH BUTTONS FOR
5 SECONDS ON THE TWO BUTTON REMOTE
WILL SOUND THE EMERGENCY SIREN
6. REPLACING BATTERIES
7. REPLACING BATTERIES
INTERNATIONAL WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on
the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels.
Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty,
if any. There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection
with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of
removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties
for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all
other warranties express or implied. For warranty service on Linear equipment return product, at sender’s expense to:
Linear Hong Kong 19/F Hounor Industrial Centre, 6 Sun Yip StreetChai Wan, Hong Kong
CAUTION: DO NOT
TOUCH OR ADJUST
ANY PARTS ON BOARD
WARNING: DO NOT
INSTALL BATTERIES
BACKWARDS, UNIT
WILL BE DAMAGED!
PLACE BOARD
ON ALIGNMENT
POSTS
PLACE FRESH BATTERIES
ON SPRING IN HOLDER
Attention: Repairs Department
REPAIRS POLICY
Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by the effects of lightning, water, fire, or other
abnormal happenings.
Customer’s equipment sent in for repair may be repaired or replaced with new or remanufactured equipment at Linear’s discretion.
The customer is always responsible for shipping and handling charges to the repairs facility. Linear will pay return shipping and handling charges
on “in warranty” products shipped back to the customer. The customer will be billed for the return shipping and handling charges on “out of
warranty” products.
SQUEEZE
CASE TOGETHER,
FLIP OVER AND
REPLACE SCREWS
HOOK CASE
HALVES
TOGETHER
There will be a 50% expedite fee for any express requests.
PLUS (+) SIDE UP
The International Sales Manager must be notified prior to the return of product to Linear. All international returns must have an International Repair
Authorization number (IRA#). The number must be marked on all packages. Failure to do so will cause delays in processing.
IMPORTANT !!!
MINUS (-) SIDE UP
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some
limitations which must be observed. The radios are required to comply with local rules and regulations as radio devices. As such, they have limited
transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating
frequencies, regardless of code settings.
Changes or modifications to the device may void regulatory compliance. Infrequently used radio links should be tested regularly to protect against
undetected interference or fault. A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer,
and these facts should be communicated to the ultimate users.
BE SURE
BATTERY SPRING
IS IN PLACE
R&TTE VAEE 27800, EMC, SFT, ETS
BATTERY TYPE
CR1616, CR1620
OR DL1620
Linear Corporation declares that the apparatus DF-41/EC and DF-42/EC
complies with the essential requirements and other relevant provisions
of Directive 1995/5/EC.
Copyright © 2003 Linear Corporation
220101 A
Download from Www.Somanuals.com. All Manuals Search And Download.
|