Linear Home Security System DF 16 EC User Manual

1. MOTION DETECTOR DETAIL  
2. TYPICAL INSTALLATION  
3. MOTION DETECTION PATTERN  
DF-54/EC  
MOTION  
9 METERS  
MOTION  
DETECTOR  
IN CORNER  
MOTION  
DETECTOR  
LENS  
DON'T POINT AT HEAT SOURCES  
(HEATERS, ETC.), WINDOWS, OTHER  
MOTION DETECTORS OR DOOR/WINDOW  
TRANSMITTERS  
BY  
DETECTOR  
For Use with DF-16/EC  
Security Console  
DETECTION  
AREA  
MOTION  
FRONT  
ROOM  
DETECTOR  
(FOR INDOOR  
USE ONLY)  
TOP  
VIEW  
WALK  
TEST  
BUTTON  
BEDROOM  
Installation  
Instructions  
MOUNT  
DETECTOR  
SO THAT  
CONSOLE  
BATH  
INTRUDER  
WILL CROSS  
BEAMS  
CASE  
LOCKING  
SCREW  
KITCHEN  
SIDE  
VIEW  
2-3 METERS  
(760) 438-7000 • FAX (760) 438-7043  
(ON BOTTOM)  
9 METERS  
4. CONNECT BATTERY  
5. MOUNT MOTION DETECTOR BASE  
6. PROGRAM DETECTOR INTO CONSOLE  
7. WALK TEST MOTION DETECTOR  
MOUNTING THE DETECTOR  
IN A CORNER IS PREFERRED  
START IN  
OFF MODE  
PUSH WALK  
TEST BUTTON  
TO SEND SIGNAL  
FROM MOTION  
DETECTOR  
PUSH  
WALK  
TEST  
BUTTON  
REMOVE  
SCREW  
AND OPEN  
CASE  
WALK IN FRONT OF  
UNIT WHILE WATCHING  
RED LIGHT  
AFTER MOUNTING, SNAP  
DETECTOR ONTO BASE  
AND REPLACE CASE SCREW  
ENTER YOUR  
SECRET CODE  
PRESS  
LEARN UNUSED SENSOR  
NUMBER  
ENTER AN  
USE SIDE HOLES  
FOR CORNER  
MOUNTING  
USE CENTER  
HOLES FOR  
WALL  
UNIT WILL STAY IN  
WALK TEST MODE  
LEARN BUTTON  
MOUNTING  
FOR 4 MINUTES AFTER  
PRESSING WALK TEST  
BUTTON THEN AUTOMATICALLY  
RETURN TO "OPERATE" MODE  
CONNECT 9-VOLT ALKALINE  
BATTERY TO BATTERY CLIP  
(PLUS SIDE UP)  
PUNCH OUT REQUIRED HOLES  
FOR SCREW MOUNTING  
WALK  
TEST  
BUTTON  
VERIFY THAT DETECTION  
PATTERN COVERS DESIRED  
AREA & THAT CONSOLE  
STATUS INDICATOR LIGHTS  
WHEN MOTION IS DETECTED  
1
MOUNT  
DETECTOR  
6-8 FEET  
HIGH  
NOTE:  
NOTE:  
WAIT 5 MINUTES AFTER  
CONNECTING BATTERY  
FOR DETECTOR  
THE DETECTOR CAN  
BE MOUNTED WITH  
DOUBLE STICK TAPE,  
HOLD OFF BUTTON  
NOTE:  
FOR 3 SECONDS WHEN  
FINISHED TO EXIT  
LEARN MODE  
AFTER INITIAL SETUP,  
WALK TEST UNIT YEARLY  
TO STABILIZE  
8. ALARM TEST MOTION DETECTOR  
9. REPLACING MOTION DETECTOR BATTERY  
10. IMPORTANT DETECTOR INFORMATION  
INTERNATIONAL WARRANTY  
1.  
This Linear product is warranted against defects in material and workmanship for twelve (12) months.  
The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale  
customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does  
not warrant this product to consumers. Consumers should inquire from their selling dealer as to  
the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of  
Linear Corporation for consequential damages arising out of or in connection with use or  
performance of this product or other indirect damages with respect to loss of property,  
revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties,  
including implied warranties for merchantability and implied warranties for fitness, are valid only until  
Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of  
all other warranties express or implied. For warranty service on Linear equipment return product,  
at sender’s expense to:  
1. The motion detector can only trigger the alarm  
WHEN CONSOLE INDICATES A LOW BATTERY  
FOR THIS SENSOR:  
PLACE CONSOLE IN THE  
AWAY MODE  
when the Console is in Away Mode.  
2. Except in “Walk Test”, the detector must see no  
motion for five minutes before walking in front of  
the unit will send an alarm signal.  
3. When the Console is in Away Mode, the motion  
detector will cause an instant alarm unless a  
delayed perimeter door/window sensor is triggered  
first.  
REMOVE  
SCREW  
AND OPEN  
CASE  
STAY OUT OF THE MOTION  
DETECTION PATTERN AREA  
FOR AT LEAST FIVE MINUTES  
Linear Hong Kong 19/F Hounor Industrial Centre,  
Attention: Repairs Department  
REPAIRS POLICY  
6
Sun Yip Street Chai Wan, Hong Kong  
AFTER FIVE MINUTES, WALKING  
IN FRONT OF THE MOTION DETECTOR  
SHOULD TRIGGER THE ALARM  
Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by  
the effects of lightning, water, fire, or other abnormal happenings.Customer’s equipment sent in for repair  
may be repaired or replaced with new or remanufactured equipment at Linear’s discretion.The customer  
is always responsible for shipping and handling charges to the repairs facility. Linear will pay return  
shipping and handling charges on “in warranty” products shipped back to the customer. The customer will  
4. Operating temperature range:  
+32° to +120° F (0° to +49° C)  
REPLACE THE BATTERY WITH  
A FRESH 9-VOLT ALKALINE  
BATTERY (PLUS SIDE UP)  
be billed for the return shipping and handling charges on “out of warranty” products.There will be  
a
50%  
expedite fee for any express requests.The International Sales Manager must be notified prior to the return  
of product to Linear. All international returns must have an International Repair Authorization number  
(IRA#). The number must be marked on all packages. Failure to do so will cause delays in processing.  
IMPORTANT !!!  
R&TTE VAEE 27837, EMC, SFT, ETS  
USE ALKALINE  
BATTERY ONLY  
Linear radio controls provide  
a
reliable communications link and fill an important need in portable wireless  
SNAP DETECTOR ONTO BASE  
AND REPLACE CASE SCREW  
WHEN FINISHED  
signaling. However, there are some limitations which must be observed. The radios are required to comply with  
local rules and regulations as radio devices. As such, they have limited transmitter power and therefore limited  
range. A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio  
signals that occur on or near their operating frequencies, regardless of code settings. Changes or modifications  
to the device may void regulatory compliance. Infrequently used radio links should be tested regularly to protect  
against undetected interference or fault. A general knowledge of radio and its vagaries should be gained prior to  
acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.  
Linear Corporation declares that the apparatus  
DF-54/EC complies with the essential requirements  
and other relevant provisions of Directive 1995/5/EC.  
PLACE CONSOLE IN OFF MODE  
TO STOP SIREN, CHECK THAT SENSOR  
STATUS LIGHT IS BLINKING.  
NOTE: WAIT 5 MINUTES AFTER REPLACING  
BATTERY FOR DETECTOR TO STABILIZE  
Copyright © 2003 Linear Corporation  
210948 B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lasko Electric Heater CC13251 User Manual
LG Electronics Refrigerator LFC23760 User Manual
LumiSource eBook Reader LSH FIREFLY FL User Manual
Mace Digital Camera CAM 76CIR User Manual
Manitowoc Ice Thermometer 76 0293 3 User Manual
Marvel Industries Beverage Dispenser 30WCM User Manual
Maverick Ventures Thermometer CT 01 User Manual
Maytag Clothes Dryer MD6400 User Manual
Maytag Dishwasher 6 915555 B User Manual
Memorex Stereo System MX4501 User Manual