Calculite® HID Downlight C6T6VN
Page 1 of 2
6" Aperture, 2pc Vertical, T6 Narrow Beam
Top View: Magnetic Ballast
Top View: Electronic Ballast
Ceiling Cutout: 6 9/16” (167 mm) Dia.
Reflector Trim
C6T6VN CLW
Frame-In Kit
Lamp
39W T6
39W T6
70W T6
70W T6
150W T6
150W T6
C639T6E1
C639T6E2
C670T6E1
C670T6E2
C615T6E1
C615T6E2
C615T6U
Electronic 120V
Ceramic Metal Halide
Ceramic Metal Halide
Ceramic Metal Halide
Ceramic Metal Halide
Ceramic Metal Halide
Ceramic Metal Halide
Ceramic Metal Halide
Specular Clear, White Painted Flange.
Specular Clear, Matching Flange.
Comfort Clear Diffuse, White Painted Flange.
Comfort Clear Diffuse, Matching Flange.
Champagne Bronze, White Painted Flange.
Champagne Bronze, Matching Flange.
Electronic 277V
Electronic 120V
Electronic 277V
Electronic 120V
Electronic 277V
CLP
CCDW
CCDP
CCZW
CCZP
Magnetic 120V/277V 150W T6
Features
Electrical (cont.)
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides narrow
beam optics ideal for high ceilings. Also available in medium and wide beam,
see C4T4VM and C4T4VW specification sheets.
150W Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting
temperature, Type 1 Outdoor rating.
2. Aperture Cone: Provides 50° visual cut-off to lamp and lamp image; self-
flange in painted white or aperture-matching polished flange. Consult factory
for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during
re-lamping. Light diffusion provides exceptionally smooth beam.
4. Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket.
Snaps onto upper reflector for secure attachment without tools; assures
proper lamp alignment to optics for consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Vertical adjustment
mechanism accommodates mounting to virtually any ceiling system using
mounting bars (provided, or 1/2" EMT tubing (by others). Single locking
feature secures all adjustments. Alignment holes and markings allow fixture
to be preset prior to installation.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
Ballast
ANSI Code Voltage Max. Amps Input Watts
39W MH M130
70W MH M139
150W MH M142
*150W MH M142
*Magnetic Ballast
120/277 0.39/0.17
120/277 0.67/0.29
120/277 1.40/0.60
120/277 3.70/1.60
44
78
169/166
180
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet
”A/E“. For 277 electronic consult factory
Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet
“A/E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Chicago Plenum: Consult Factory.
Labels
cULus (Suitable for Damp Locations), I.B.E.W. For 150W, install fixtures with
minimum spacing; 3 feet from center-to center of adjacent luminaries, 3” from
top of luminaire to overhead building member; 1 1/2 feet from luminaire center to
side building member.
7. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to
30" long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies
installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
Job Information
Type:
8. Trim Retention Springs: Rust resistant springs secure reflector/housing for
quick, tool-less installation.
Job Name:
Cat. No.:
9. Ballast / Socket Housing / Cover Assembly: Snaps onto junction box
without tools for inspection and ballast replacement, accessible from below.
10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Lamp(s):
Notes:
Electrical
Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating “A”,
-5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating.
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Lightolier is a Philips group brand
Download from Www.Somanuals.com. All Manuals Search And Download.
|