Kobe Range Hoods Ventilation Hood IS2336SQ User Manual

KOBE Brand Range Hood  
Model No. IS2336SQ  
IS2342SQ  
IS-123 SERIES – 7” HEIGHT  
INSTALLATION INSTRUCTIONS  
AND OPERATION MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -  
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,  
OBSERVE THE FOLLOWING:  
1) Installation and electrical wiring must be done by qualified professionals and in accordance  
with all applicable codes and standards, including fire-rated construction.  
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other  
hidden utilities.  
3) Ducted fans must be vented to the outside.  
a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT  
SERVICE PANEL.  
b) Clean fan, optional filter and grease laden surfaces frequently. To reduce the risk of fire  
and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust air into  
wall spaces, attics, crawl spaces or garages.  
NOTE - This warranty is invalid without an authorized agent’s  
receipt or if unit is damaged due to misuse, poor  
installation, improper use, mistreatment, negligence or  
any other circumstances beyond the control of KOBE  
RANGE HOODS authorized agents. Any repair carried  
out without the supervision of KOBE RANGE HOODS  
authorized agents will automatically void the warranty.  
- KOBE RANGE HOODS will not be held responsible for  
any damages to personal property or real estate or any  
bodily injuries whether caused directly or indirectly by  
the range hood.  
WARNING – TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE  
TOP GREASE FIRE:  
Keep fan, filter, if any, and grease-laden surfaces clean.  
Always turn hood ON when cooking at high heat.  
Use high settings on cooking range ONLY when necessary. Heat the oil slowly on low to  
medium setting.  
Do not leave cooking range unattended when cooking.  
Always use cookware and utensils appropriate for the type and amount of food prepared.  
Use this unit only in the manner intended by the manufacturer.  
Before servicing, switch power off at service panel and lock service panel (if possible) to  
prevent power from switching on accidentally.  
Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan,  
filter, and oil containers.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
What to Do In The Event Of a Range Top Grease Fire  
-
SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the  
burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the  
flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE  
DEPARTMENT or 911.  
- NEVER PICK UP A BURNING PAN – You may get burned.  
DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.  
-
- Use an extinguisher ONLY if:  
a) You have a Class A, B, C extinguisher and know how to operate it.  
b) The fire is small and contained in the area where it started.  
c) The fire department has been called.  
d) You can fight the fire with your back to an exit.  
What to Do If You Smell Gas  
-
-
-
Extinguish any open flame.  
Do not try to turn on the lights or any type of appliance.  
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company  
and Fire Department right away.  
CAUTION  
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and  
vapors.  
2) To reduce the risk of fire, use only metal ductwork.  
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those  
published by the National Fire Protection Association (NFPA), and the American Society for  
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.  
4) Activating any switch may cause ignition or an explosion.  
ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.  
Disconnect appliance from electric power before servicing.  
If equipped, the fluorescent light bulb contains small amounts of mercury,  
which must be recycled or disposed of according to Local, State, and  
Federal Codes.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
(M ust keep all m aterial for returns or refunds)  
BOX 1:  
{A} KOBE Range Hood  
{B} Mounting Template  
{C} Warranty Registration Card  
{D} Instructions Manual  
{A}  
{B}  
{C}  
{D}  
ORIGINAL KIT  
BOX 2 (SOLD SEPARATELY):  
{G}  
{H}  
{G}  
{H}  
{E} Telescopic Stack  
{F} Two-Piece Duct Cover  
{G} Screws Package  
{H} Filter Set  
{E}  
{F}  
(Model No. IS123F)  
- Mesh Filter x 2  
- Safety Screen x 2  
- Oil Container (Round) x 2  
- Screw x 2  
RECIRCULATING KIT  
BOX 2 (SOLD SEPARATELY):  
{E} Telescopic Stack  
{F} Two-Piece Duct Cover  
{G} Screws Package  
{H} Charcoal Filter Set  
(Model No. RH-CH01)  
- Charcoal Filter x 2  
- Mesh Filter x 2  
{E}  
{F}  
- Safety Screen x 2  
- Oil Container (Round) x 2  
- Screw x 2  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING  
Calculation before Installations  
To calculate the length of the installation, please refer to Table 1. (All calculation is measure in  
inches.)  
TABLE 1  
A = Height of Floor to Ceiling  
B = Height of Floor to Counter Top  
(Standard: 36”)  
C = Preferred Height of Counter Top  
to Hood Bottom (Recommended  
30” to 36”)  
D = Height of Hood  
E = Height of the Hood Installation  
[A – (B+C)]  
F = Height of Duct Cover  
[E – D]  
SAFETY WARNING  
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT  
IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR  
SERVICING.  
Preparations of Ductwork and Location  
NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE  
VENT OPENING.  
-
-
-
Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.  
A straight, short venting run will allow the hood to perform more efficiently.  
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the  
performance of the hood.  
- Use duct tape to seal the joints between pipe sections.  
Figure 1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telescopic Stack Installation  
Note: Duct cover with telescopic stack sold separately.  
1. Mark centerlines of cook top or range on ceiling above. Use centerlines marked on ceiling  
to position the mounting template as shown in Figure 2.  
2. Remove and save template. Cut and remove ceiling drywall. Install 2” x 4” cross framing  
lumber (not provided) between ceiling joists. Refer to Figure 3. Consult a professional if  
you have difficulty or your installation is unique.  
3. Finish the ceiling surface. Be sure to mark the location of the ceiling joists and cross  
framing, or replace the mounting template in the position of the ceiling joists & cross  
framing.  
4. Attach the telescopic stack to the ceiling and securely fasten to the joists and cross framing  
with eight screws (not provided) as shown in Figure 3. Make sure screws are driven into  
center of joists and cross framing for maximum support.  
5. Adjust the telescopic stack using reference F calculated in Table 1 and measurements on  
page 12. Tighten from the side with eight (4x8 mm) screws (provided) as shown in Figure  
4.  
Figure 2  
Figure 3  
Figure 4  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duct Cover Installation  
6. Slide the duct cover up and secure the inner duct cover to the telescopic stack with four  
(4x8 mm) screws (provided). Refer to Figure 5.  
Hood Installation  
7. Place temporary screws to hold the duct cover up. Install the hood as shown in Figure 6.  
8. Use eight (3/16x3/8 mm) screws (provided) to secure hood to telescopic stack. Make sure  
to tighten screws securely. Refer to Figure 6.  
Figure 6  
Figure 5  
Wiring to Power Supply  
SAFETY WARNING  
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.  
MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL  
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING  
WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO  
PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.  
9. Remove the wiring box cover as shown in Figure 7. Remove the knockout from the wiring  
box.  
10. Connect three wires (black, white and green) to house wires and cap with wire connectors  
11. Connect according to color. Black to black, white to white, and green to green.  
12. Close the wiring box cover and make sure that wires are not pinched between cover and  
box.  
13. Test the operation of the hood before moving on to next step. Make sure power is supplied  
to the hood.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ductwork Installation  
Note: Skip this step if installing recirculating kit.  
14. Use 6” round pipe to connect the plastic exhaust on the hood to the ductwork above.  
15. Use duct tape to make all joints secure and air tight.  
Final Assembly  
16. Remove the temporary screws and slide the outer duct cover downward so that it sits  
properly on the hood.  
17. NOTE: Be careful when using electrical screwdriver, damage to the hood may occur.  
Secure the duct cover to hood with four (4x8 mm) screws (provided) as shown in Figure 8.  
18. Turn power ON in control panel. Check all lights and fan operation.  
19. Make sure to leave this manual for the homeowner.  
Figure 7  
Figure 8  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
This KOBE hood is equipped with four electronic controls with a 10-second standby startup &  
30-second delay shutoff, two powerful centrifugal turbine impellers, and four bright 12-volt 20-  
watt halogen lights.  
The four control buttons are Light Control, Speed Control A (cycles through Low, Medium, High,  
QuietMode), Speed Control B (cycles through Low, QuietMode, High, Medium) and the  
Power Control (On/Off). Refer to Figure 9.  
Figure 9  
Light Control  
Power Control  
Speed Control A  
Speed Control B  
(Cycles through Low, Medium, High, QuietMode) (Cycles through Low, QuietMode, High, Medium)  
Turn On:  
-
-
-
-
Press Power Control (On/Off) button once. (If any Control button is not pressed within  
10 seconds, power will be automatically turned off).  
The KOBE hood will start on Low speed. Each press of the Speed Control button will  
cycle through the various speeds.  
Press Speed Control A button to cycle from Low, Medium, High, or QuietMode.  
Press Speed Control B button to cycle from Low, QuietMode, High or Medium.  
Press Light Control button to turn halogen light on.  
Turn Off:  
-
Press Power Control (On/Off) button once, panel lights will flash and power will be  
completely shut off after 30 seconds.  
OR  
-
-
Press Power Control (On/Off) button twice, all power will be shut off immediately.  
If only the lights are on, pressing Power Control (On/Off) button once will turn power  
off after 30 seconds.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING THE FAN WHILE THE  
FAN IS OPERATING.  
For the optimal level of operation, clean the range hood surface, filter set, and oil containers  
regularly.  
To Clean Hood Surface  
CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.  
*** Regular care will help preserve its fine appearance.  
1) Use only mild soap or detergent solutions. Dry surfaces using soft cloth.  
2) If hood looks splotchy (stainless steel hood), use an orange base cleaner to clean the  
surface of the hood. Avoid getting cleaning solution on the control switches. Only spread  
a light coating over the surface of the hood and leave on for a few minutes (do not leave  
on too long or this may cause damage to hood finish). Use soft towel to wipe off the  
cleaning solution, gently rub off any stubborn spots. Use a slightly damp towel to get rid  
of any cleaning solution. Use dry soft towel to dry the hood.  
3) To bring the glow back into a stainless steel finish, use a stainless steel cleaner.  
4) DO NOT allow deposits to remain for long periods of time.  
5) DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the  
surface and cause rust.  
6) DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in  
contact with stainless steel for extended periods. Many of these compounds contain  
chemicals, which may be harmful. Rinse with water after exposure and dry with a clean  
cloth.  
To Clean Filter Sets and Oil Containers  
CAUTION: DRAIN OIL CONTAINER BEFORE OIL CAN OVERFLOW.  
1) Normal Cleaning  
-
Spray a mild degreaser into the fan and turn on high speed. Liquid residue will  
accumulate in the oil containers (round).  
2) Cleaning Oil Containers  
-
-
-
Remove the oil container by turning counter-clockwise.  
Wash with warm soapy water. Dry completely before returning into place.  
Top rack dishwasher safe.  
3) Cleaning Filter Set or Charcoal Filter Set  
-
-
-
-
-
Remove the safety screen screw and slide the filter set or charcoal filter set out.  
Remove oil container by turning counter-clockwise.  
Wash with warm soapy water.  
Dry completely before returning into place.  
Top rack dishwasher safe.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Replace Light Bulb  
CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.  
1) Make sure all control switches are off, and range hood is unplugged.  
2) Use a flat head screwdriver to pop out the protective covering as shown in Figure 10.  
3) Gently pull out the defective light bulb and discard. Light bulb should be 12V 20W  
maximum. Refer to Figure 11. Push bulb securely into light socket.  
4) Replace protective cover.  
5) Plug in range hood.  
Figure 10  
Figure 11  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL / SIZE  
IS2336SQ / 36”  
IS2342SQ / 42”  
COLOR  
#304 Commercial Grade Stainless Steel  
VOLTAGE  
120V 60Hz  
NUMBER OF MOTORS  
DESIGN  
2
18-Gauge Seamless  
Twin Turbine Impeller  
6” Round  
FAN TYPE  
EXHAUST  
CONTROLS  
Electronic Control (4 Buttons) –  
10-Second Standby Startup  
30-Second Delay Shutoff  
HALOGEN LIGHTS  
12V 20W x 4  
HOOD  
DIMENSION (W x D x H)  
(IS2336SQ) 35-3/4” x 27” x 7”  
(IS2342SQ) 41-3/4” x 27” x 7”  
TELESCOPIC STACK  
DIMENSION (W x D x H)  
Two-Piece Adjustable Telescopic Stack  
1) Original Kit (Sold Separately):  
(IS123DC) 11-1/8” x 9-1/8” x (22-5/8”~36-3/8”)  
(IS123-16DC) 11-1/8” x 9-1/8” x (16”)  
(IS123-59DC) 11-1/8” x 9-1/8” x (33-5/8”~58-1/2”)  
2) Recirculating Kit (Sold Separately):  
(IS123DCD) 11-1/8” x 9-1/8” x (22-5/8”~36-3/8”)  
(IS123-16DCD) 11-1/8” x 9-1/8” x (16”)  
(IS123-59DCD) 11-1/8” x 9-1/8” x (33-5/8”~58-1/2”)  
DUCT COVER  
Two-Piece Adjustable Duct Cover  
DIMENSION (W x D x H)  
1) Original Kit (Sold Separately):  
(IS123DC) 11-3/8” x 9-1/2” x (18-1/8”~37-3/8”)  
(IS123-16DC) 11-3/8” x 9-1/2” x (9-1/4”~17-1/2”)  
(IS123-59DC) 11-3/8” x 9-1/2” x (30-1/4”~59-1/4”)  
2) Recirculating Kit (Sold Separately):  
(IS123DCD) 11-3/8” x 9-1/2” x (18-1/8”~37-3/8”)  
(IS123-16DCD) 11-3/8” x 9-1/2” x (9-1/4”~17-1/2”)  
(IS123-59DCD) 11-3/8” x 9-1/2” x (30-1/4”~59-1/4”)  
IS2336SQ IS2342SQ  
NET WEIGHT (lbs)  
GROSS WEIGHT (lbs)  
Hood:  
Hood:  
53.0  
73.0  
55.0  
77.0  
SPEED  
Air Capacity (cfm)*  
(Original / Recirculating)  
Low  
Medium  
720 / 330  
4.5 / 4.5  
High  
QuietMode  
500 / 150  
640 / 200  
3.0 / 3.0  
800 / 400  
4.8 / 4.8  
Sone (Original / Recirculating)  
*In House Test Static Pressure “0”. One sone is equivalent to the sound of a refrigerator at 40 decibels.  
1.0* / 1.0*  
**Specifications subject to change without notice.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
***All inch measurements are converted from millimeters. Inch measurements are estimated.  
***All measurements in ( ) are millimeters.  
ORIGINAL KIT (Sold Separately)  
MODEL NO.  
IS123DC  
A
B
DCH  
C
D
TSH  
MAX. HT.  
INTSALLED  
36-3/8”  
(925)  
18-1/8”  
(460)  
9-1/4”  
(235)  
30-1/4”  
(770)  
19-1/4”  
(490)  
8-1/4”  
(210)  
29”  
37-3/8  
(950)  
17-1/2”  
(445)  
59-1/4”  
(1505)  
14-5/8”  
(370)  
-
22-5/8”  
(575)  
-
37-1/4”  
(946)  
16”  
(405)  
59-1/4”  
(1505)  
IS123-16DC  
IS123-59DC  
16”  
(405)  
58-1/2”  
(1485)  
25-5/8”  
(650)  
33-5/8”  
(854)  
(735)  
DUCT COVER  
TELESCOPIC STACK  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECIRCULATING KIT (Sold Separately)  
MODEL NO.  
IS123DCD  
A
B
DCH  
C
D
TSH  
MAX. HT.  
INTSALLED  
36-3/8”  
(925)  
18-1/8”  
(460)  
9-1/4”  
(235)  
30-1/4”  
(770)  
19-1/4”  
(490)  
8-1/4”  
(210)  
29”  
37-3/8  
(950)  
17-1/2”  
(445)  
59-1/4”  
(1505)  
14-5/8”  
(370)  
-
22-5/8”  
(575)  
-
37-1/4”  
(946)  
16”  
(405)  
59-1/4”  
(1505)  
IS123-16DCD  
IS123-59DCD  
16”  
(405)  
58-1/2”  
(1485)  
25-5/8”  
(650)  
33-5/8”  
(854)  
(735)  
DUCT COVER  
TELESCOPIC STACK  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL NO.: IS2336SQ  
IS2342SQ  
KEY NO. DESCRIPTION  
MODEL /SIZE  
PART NO.  
1
2
3
4
5
Power Cord  
C1-0406-0120-01  
C1-0505-0001  
C1-0708-0006  
B101-1242-13  
B101-1236-02  
B101-1242-02  
C1-0202-1242  
C1-0402-0120-40  
6” Round Plastic Exhaust  
Round Head Screw (TS 4 x 6)  
Hood Roof  
Hood Casing  
IS2336SQ  
IS2342SQ  
6
7
Transformer Bracket  
Transformer (Light)  
C1-0707-0001  
C1-0403-0101  
C1-0201-1242  
C1-0707-0001  
C1-0401-0120-01A  
C1-0707-0001  
8
Transformer Bracket Screw (3/16” x 3/8”)  
Halogen Light (12V 20W Max.)  
Transformer Support (Light)  
Screw (3/16” x 3/8”)  
9
10  
11  
12  
13  
Capacitor  
Round Head Screw (TS 4 x 6)  
14  
15  
16  
17  
A
Processor Board Box  
Processor Board  
Flat Head Screw (M 2 x 8)  
Air Chamber  
Air Chamber (Top)  
Air Chamber (Side)  
Motor (Left)  
C1-0501-0102  
C1-0404-0401-B  
C1-0704-0003  
C1-0102-1242  
C1-0101-1242  
C1-0301-0120-07A  
C1-0301-0120-08A  
C1-0251-0092-01  
C1-0251-0092-02  
C1-0502-0201  
B101-1236-09  
B
18  
19  
20  
21  
22  
23  
Motor (Right)  
Turbine Impeller (Left)  
Turbine Impeller (Right)  
Oil Tunnel  
Bottom Casing  
IS2336SQ  
IS2342SQ  
B101-1242-09  
24  
25  
Impeller Plastic Cover  
Motor Position Screw (3/16” x 5/8”)  
C1-0251-0001  
C1-0703-0001  
26  
27  
28  
29  
30  
31  
Bottom Casing Screw (3/16” x 5/8”)  
Transformer Screw (3/16” x 3/8”)  
Control Board  
Control Unit  
Round Head Screw (TS 1/8” x 3/8”)  
Transformer (Motor)  
C1-0704-0001  
C1-0707-0001  
C1-0404-0401-A  
C1-0501-0101  
C1-0708-0003  
C1-0402-0120-40  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL NO.: IS123DC  
ORIGINAL KIT (Sold Separately)  
KEY NO. DESCRIPTION  
MODEL /SIZE  
PART NO.  
01  
Duct Cover  
IS123DC  
12-04000-304-51  
IS123-16DC  
IS123-59DC  
12-04016-304-51  
12-04059-304-51  
C1-0707-0001  
02  
03  
Round Head Screw (3/16” x 3/8”)  
Telescopic Stack  
IS123DC  
IS123-16DC  
IS123-59DC  
C1-0203-1242-36  
C1-0203-1242-16  
C1-0203-1242-59  
C1-0708-0001  
C1-0707-0001  
C1-0101-0001  
04  
05  
06  
07  
A
B
C
D
Round Head Screw (3/16” x 3/8”)  
Duct Cover Screw (3 x 8 mm)  
Round Head Screw (TS 4 x 6)  
Filter Set  
Mesh Filter  
Safety Screen  
IS123F  
MF-0201  
C1-0604-0201  
C1-0602-0202  
C1-0503-0201  
Oil Container (Round)  
C1-0705-0001  
Safety Screen Screw  
MODEL NO.: IS123DCD  
RECIRCULATING KIT (Sold Separately)  
KEY NO. DESCRIPTION  
MODEL /SIZE  
IS123DCD  
IS123-16DCD  
IS123-59DCD  
PART NO.  
01  
Duct Cover (Recirculating)  
12-04000-304-51F  
12-04016-304-51F  
12-04059-304-51F  
C1-0707-0001  
C1-0203-1242F36  
C1-0203-1242F16  
C1-0203-1242F59  
C1-0708-0001  
02  
03  
Round Head Screw (3/16” x 3/8”)  
Telescopic Stack  
IS123DCD  
IS123-16DCD  
IS123-59DCD  
04  
05  
06  
07  
A
Round Head Screw (3/16” x 3/8”)  
Duct Cover Screw (3 x 8 mm)  
Round Head Screw (TS 4 x 6)  
Charcoal Filter Set  
C1-0707-0001  
C1-0101-0001  
RH-CF01  
MF-0201  
Charcoal Filter  
C1-0603-0302  
C1-0604-0201  
C1-0602-0202  
C1-0503-0201  
C1-0705-0001  
B
C
D
E
Mesh Filter  
Safety Screen  
Oil Container (Round)  
Safety Screen Screw  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL NO.: IS2336SQ  
IS2342SQ  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL NO.: IS2336SQ  
IS2342SQ  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING  
DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT.  
REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY  
TO SUPPORT YOUR CLAIM.  
Upon acceptance of items, owner assumes responsibility for its safe arrival. Damages  
should be reported to carrier and a claim filed. Failure to do this could result in the carrier  
refusing to honor your claim. The carrier will furnish you with necessary forms for filing a  
claim.  
DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR  
WARRANTY.  
2. PLEASE INSPECT CONTENTS OF PACKAGE (S) CAREFULLY UPON RECEIVING!  
We must be notified in writing of any damages and/or missing parts within the allocated  
days upon receipt of package(s). Contact your local KOBE dealer or distributor or call  
KOBE for the time limit.  
CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS.  
NOTE: ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR  
FACTORY.  
3. Products must be returned in good working condition with ALL original parts and  
documentation packed in ALL original cartons, fillers and shipping cartons. A restocking  
fee of 25% will be charged for all approved return(s).  
EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS  
MISSING.  
4. MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE  
INSTALLATION. Appearance flaws of the hood found after installation and not affecting  
hood performance is not covered under our warranty for returns or exchanges. Service  
visits not covered under warranty will carry a service charge.  
A) Before Installation: Return for exchange or refund (please see above for  
acceptable returns).  
B) After Installation: NO exchange or refund.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY CERTIFICATE  
KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from  
defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a  
period of two years from the date of purchase and to the repair or replacement at its option and  
subject to the terms and conditions stated below, of any component part, which its examination  
shall disclose to be so defective.  
TWO-YEAR WARRANTY SERVICE PERIOD  
Any covered failure occurring within two years of original purchase arising from defective  
workmanship or material in manufacture will be repaired (or at our option the unit will be  
replaced) free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as  
applicable. Keep proof of purchase (or original invoice) handy for inspection.  
If the range hood is sold by the original purchaser during the warranty period the new owner is  
protected until expiration of the original purchaser’s warranty.  
CONDITIONS  
The following conditions apply only in relation to the warranty expressly given in this certificate.  
1) This warranty applies only:  
a) within U.S.A. and Canada.  
b) to range hoods used for PRIVATE SINGLE FAMILY USE (if used for COMMERCIAL or  
MULTIPLE FAMILY USE or other purposes, warranty will be voided).  
2) Repair of any fault to be provided under this warranty shall not be provided:  
a) if the identification number attached to the range hood has been altered, rendered  
illegible or removed;  
b) if notice of the defect has not been given within the period applicable;  
c) for failure of light bulbs;  
d) for physical damage;  
e) for surfaces damaged by use of improper chemical cleaning agents;  
f) if the appliance has been:  
i) subject to misuse, abuse, negligence, accident, incorrect installation or failure to follow  
the operating instructions;  
ii) connected to improper, inadequate or faulty electricity service or exhaust ducts or  
flues or operated using incorrect or contaminated lubricants;  
iii) installed, maintained or operated otherwise than in accordance with the instructions  
furnished by KOBE Range Hoods including the improper use of detergents, bleaches,  
or cleaners.  
g) for damage to range hood during transit, delivery, installation or removal;  
h) for damage by or resulting from attempted repairs conducted by anyone other than our  
Authorized Service Agent.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3) The purchaser shall be responsible for any expenses involved in making the range hood  
readily accessible for servicing and where the range hood is installed outside the main sales  
territory of the retailer or service territory of the nearest approved KOBE Range Hoods Agent  
as applicable, for any traveling expenses and any costs of transporting the range hood or  
parts thereof to and from the dealer or Service Agent  
4) The purchaser must produce proof of purchase together with this warranty certificate when  
making the claim.  
5) Damages caused during shipment are not covered under our warranty.  
CONSEQUENTIAL DAMAGE  
The warrantor is not responsible for any consequential damage. SOME STATES DO NOT  
ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION  
MAY NOT APPLY TO YOU.  
IMPLIED WARRANTIES/STATE LAW  
Any implied warranties, including the implied warranty of merchantability and fitness for purpose,  
imposed on the sale by the laws of the state of sale are limited to two year from the date of  
original purchase. Some states do not allow limitations on the duration of implied warranties.  
This warranty gives you specific legal rights, and may also have rights, which vary from state to  
state.  
SERVICE  
For service contact:  
KOBE Range Hoods, Inc.  
4934 Walnut Grove Avenue  
Suite 202  
San Gabriel, CA 91776  
U.S.A  
Tel: (626) 309-1356 Fax: (626) 309-1366  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Register Your Product!  
Any covered failure occurring within two years of original purchase arising from defective  
workmanship or material in manufacture will be repaired or at our option the unit will be  
replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods  
as applicable. Keep proof of purchase (original invoice) handy for inspection.  
If the range hood is sold by the original purchaser during the warranty period the new owner  
is protected until expiration of the original purchaser’s warranty. See warranty section for  
complete warranty coverage information.  
This appliance has been manufactured, tested, and inspected to the standards required by  
KOBE Range Hoods.  
PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF  
PURCHASE TO:  
KOBE Range Hoods, Inc.  
4934 Walnut Grove Avenue  
Suite 202  
San Gabriel, CA 91776  
RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD:  
Model No. ________________________  
Serial No. ________________________  
Purchased Date  
Purchased From:  
_____/_____/_____  
______________________________  
______________________________  
______________________________  
IMPORTANT: PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY  
WHEN REQUESTING FOR SERVICE.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Infinity Portable Speaker TSS 3 IN 1 User Manual
Insignia Handheld TV 10 0499 User Manual
JBL Portable Speaker Portable Loudspeaker System User Manual
JVC DVD Recorder SR MV50U User Manual
Kathrein Satellite Radio 260376 User Manual
Kawasaki Grinder 840066 User Manual
Kenmore Dehumidifier 251907Q1 User Manual
Kenwood Cooktop CK 780 User Manual
Kenwood Speaker KFC W2509 User Manual
Konica Minolta All in One Printer C30P User Manual