KOBE Brand Range Hood
Model No. IS2336SQ
IS2342SQ
IS-123 SERIES – 7” HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
Download from Www.Somanuals.com. All Manuals Search And Download.
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,
OBSERVE THE FOLLOWING:
1) Installation and electrical wiring must be done by qualified professionals and in accordance
with all applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other
hidden utilities.
3) Ducted fans must be vented to the outside.
a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT
SERVICE PANEL.
b) Clean fan, optional filter and grease laden surfaces frequently. To reduce the risk of fire
and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust air into
wall spaces, attics, crawl spaces or garages.
NOTE - This warranty is invalid without an authorized agent’s
receipt or if unit is damaged due to misuse, poor
installation, improper use, mistreatment, negligence or
any other circumstances beyond the control of KOBE
RANGE HOODS authorized agents. Any repair carried
out without the supervision of KOBE RANGE HOODS
authorized agents will automatically void the warranty.
- KOBE RANGE HOODS will not be held responsible for
any damages to personal property or real estate or any
bodily injuries whether caused directly or indirectly by
the range hood.
WARNING – TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
TOP GREASE FIRE:
Keep fan, filter, if any, and grease-laden surfaces clean.
Always turn hood ON when cooking at high heat.
Use high settings on cooking range ONLY when necessary. Heat the oil slowly on low to
medium setting.
Do not leave cooking range unattended when cooking.
Always use cookware and utensils appropriate for the type and amount of food prepared.
Use this unit only in the manner intended by the manufacturer.
Before servicing, switch power off at service panel and lock service panel (if possible) to
prevent power from switching on accidentally.
Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan,
filter, and oil containers.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
What to Do In The Event Of a Range Top Grease Fire
-
SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the
burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the
flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE
DEPARTMENT or 911.
- NEVER PICK UP A BURNING PAN – You may get burned.
DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.
-
- Use an extinguisher ONLY if:
a) You have a Class A, B, C extinguisher and know how to operate it.
b) The fire is small and contained in the area where it started.
c) The fire department has been called.
d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
-
-
Extinguish any open flame.
Do not try to turn on the lights or any type of appliance.
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company
and Fire Department right away.
CAUTION
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and
vapors.
2) To reduce the risk of fire, use only metal ductwork.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch may cause ignition or an explosion.
ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.
Disconnect appliance from electric power before servicing.
If equipped, the fluorescent light bulb contains small amounts of mercury,
which must be recycled or disposed of according to Local, State, and
Federal Codes.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
(M ust keep all m aterial for returns or refunds)
BOX 1:
{A} KOBE Range Hood
{B} Mounting Template
{C} Warranty Registration Card
{D} Instructions Manual
{A}
{B}
{C}
{D}
ORIGINAL KIT
BOX 2 (SOLD SEPARATELY):
{G}
{H}
{G}
{H}
{E} Telescopic Stack
{F} Two-Piece Duct Cover
{G} Screws Package
{H} Filter Set
{E}
{F}
(Model No. IS123F)
- Mesh Filter x 2
- Safety Screen x 2
- Oil Container (Round) x 2
- Screw x 2
RECIRCULATING KIT
BOX 2 (SOLD SEPARATELY):
{E} Telescopic Stack
{F} Two-Piece Duct Cover
{G} Screws Package
{H} Charcoal Filter Set
(Model No. RH-CH01)
- Charcoal Filter x 2
- Mesh Filter x 2
{E}
{F}
- Safety Screen x 2
- Oil Container (Round) x 2
- Screw x 2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installations
To calculate the length of the installation, please refer to Table 1. (All calculation is measure in
inches.)
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter Top
(Standard: 36”)
C = Preferred Height of Counter Top
to Hood Bottom (Recommended
30” to 36”)
D = Height of Hood
E = Height of the Hood Installation
[A – (B+C)]
F = Height of Duct Cover
[E – D]
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT
IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR
SERVICING.
Preparations of Ductwork and Location
NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE
VENT OPENING.
-
-
-
Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
A straight, short venting run will allow the hood to perform more efficiently.
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the
performance of the hood.
- Use duct tape to seal the joints between pipe sections.
Figure 1
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Telescopic Stack Installation
Note: Duct cover with telescopic stack sold separately.
1. Mark centerlines of cook top or range on ceiling above. Use centerlines marked on ceiling
to position the mounting template as shown in Figure 2.
2. Remove and save template. Cut and remove ceiling drywall. Install 2” x 4” cross framing
lumber (not provided) between ceiling joists. Refer to Figure 3. Consult a professional if
you have difficulty or your installation is unique.
3. Finish the ceiling surface. Be sure to mark the location of the ceiling joists and cross
framing, or replace the mounting template in the position of the ceiling joists & cross
framing.
4. Attach the telescopic stack to the ceiling and securely fasten to the joists and cross framing
with eight screws (not provided) as shown in Figure 3. Make sure screws are driven into
center of joists and cross framing for maximum support.
5. Adjust the telescopic stack using reference F calculated in Table 1 and measurements on
page 12. Tighten from the side with eight (4x8 mm) screws (provided) as shown in Figure
4.
Figure 2
Figure 3
Figure 4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Duct Cover Installation
6. Slide the duct cover up and secure the inner duct cover to the telescopic stack with four
(4x8 mm) screws (provided). Refer to Figure 5.
Hood Installation
7. Place temporary screws to hold the duct cover up. Install the hood as shown in Figure 6.
8. Use eight (3/16x3/8 mm) screws (provided) to secure hood to telescopic stack. Make sure
to tighten screws securely. Refer to Figure 6.
Figure 6
Figure 5
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
9. Remove the wiring box cover as shown in Figure 7. Remove the knockout from the wiring
box.
10. Connect three wires (black, white and green) to house wires and cap with wire connectors
11. Connect according to color. Black to black, white to white, and green to green.
12. Close the wiring box cover and make sure that wires are not pinched between cover and
box.
13. Test the operation of the hood before moving on to next step. Make sure power is supplied
to the hood.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Ductwork Installation
Note: Skip this step if installing recirculating kit.
14. Use 6” round pipe to connect the plastic exhaust on the hood to the ductwork above.
15. Use duct tape to make all joints secure and air tight.
Final Assembly
16. Remove the temporary screws and slide the outer duct cover downward so that it sits
properly on the hood.
17. NOTE: Be careful when using electrical screwdriver, damage to the hood may occur.
Secure the duct cover to hood with four (4x8 mm) screws (provided) as shown in Figure 8.
18. Turn power ON in control panel. Check all lights and fan operation.
19. Make sure to leave this manual for the homeowner.
Figure 7
Figure 8
7
Download from Www.Somanuals.com. All Manuals Search And Download.
This KOBE hood is equipped with four electronic controls with a 10-second standby startup &
30-second delay shutoff, two powerful centrifugal turbine impellers, and four bright 12-volt 20-
watt halogen lights.
The four control buttons are Light Control, Speed Control A (cycles through Low, Medium, High,
QuietMode), Speed Control B (cycles through Low, QuietMode, High, Medium) and the
Power Control (On/Off). Refer to Figure 9.
Figure 9
Light Control
Power Control
Speed Control A
Speed Control B
(Cycles through Low, Medium, High, QuietMode) (Cycles through Low, QuietMode, High, Medium)
Turn On:
-
-
-
-
Press Power Control (On/Off) button once. (If any Control button is not pressed within
10 seconds, power will be automatically turned off).
The KOBE hood will start on Low speed. Each press of the Speed Control button will
cycle through the various speeds.
Press Speed Control A button to cycle from Low, Medium, High, or QuietMode.
Press Speed Control B button to cycle from Low, QuietMode, High or Medium.
Press Light Control button to turn halogen light on.
Turn Off:
-
Press Power Control (On/Off) button once, panel lights will flash and power will be
completely shut off after 30 seconds.
OR
-
-
Press Power Control (On/Off) button twice, all power will be shut off immediately.
If only the lights are on, pressing Power Control (On/Off) button once will turn power
off after 30 seconds.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING THE FAN WHILE THE
FAN IS OPERATING.
For the optimal level of operation, clean the range hood surface, filter set, and oil containers
regularly.
To Clean Hood Surface
CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.
*** Regular care will help preserve its fine appearance.
1) Use only mild soap or detergent solutions. Dry surfaces using soft cloth.
2) If hood looks splotchy (stainless steel hood), use an orange base cleaner to clean the
surface of the hood. Avoid getting cleaning solution on the control switches. Only spread
a light coating over the surface of the hood and leave on for a few minutes (do not leave
on too long or this may cause damage to hood finish). Use soft towel to wipe off the
cleaning solution, gently rub off any stubborn spots. Use a slightly damp towel to get rid
of any cleaning solution. Use dry soft towel to dry the hood.
3) To bring the glow back into a stainless steel finish, use a stainless steel cleaner.
4) DO NOT allow deposits to remain for long periods of time.
5) DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the
surface and cause rust.
6) DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in
contact with stainless steel for extended periods. Many of these compounds contain
chemicals, which may be harmful. Rinse with water after exposure and dry with a clean
cloth.
To Clean Filter Sets and Oil Containers
CAUTION: DRAIN OIL CONTAINER BEFORE OIL CAN OVERFLOW.
1) Normal Cleaning
-
Spray a mild degreaser into the fan and turn on high speed. Liquid residue will
accumulate in the oil containers (round).
2) Cleaning Oil Containers
-
-
-
Remove the oil container by turning counter-clockwise.
Wash with warm soapy water. Dry completely before returning into place.
Top rack dishwasher safe.
3) Cleaning Filter Set or Charcoal Filter Set
-
-
-
-
-
Remove the safety screen screw and slide the filter set or charcoal filter set out.
Remove oil container by turning counter-clockwise.
Wash with warm soapy water.
Dry completely before returning into place.
Top rack dishwasher safe.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
To Replace Light Bulb
CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.
1) Make sure all control switches are off, and range hood is unplugged.
2) Use a flat head screwdriver to pop out the protective covering as shown in Figure 10.
3) Gently pull out the defective light bulb and discard. Light bulb should be 12V 20W
maximum. Refer to Figure 11. Push bulb securely into light socket.
4) Replace protective cover.
5) Plug in range hood.
Figure 10
Figure 11
10
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL / SIZE
IS2336SQ / 36”
IS2342SQ / 42”
COLOR
#304 Commercial Grade Stainless Steel
VOLTAGE
120V 60Hz
NUMBER OF MOTORS
DESIGN
2
18-Gauge Seamless
Twin Turbine Impeller
6” Round
FAN TYPE
EXHAUST
CONTROLS
Electronic Control (4 Buttons) –
10-Second Standby Startup
30-Second Delay Shutoff
HALOGEN LIGHTS
12V 20W x 4
HOOD
DIMENSION (W x D x H)
(IS2336SQ) 35-3/4” x 27” x 7”
(IS2342SQ) 41-3/4” x 27” x 7”
TELESCOPIC STACK
DIMENSION (W x D x H)
Two-Piece Adjustable Telescopic Stack
1) Original Kit (Sold Separately):
(IS123DC) 11-1/8” x 9-1/8” x (22-5/8”~36-3/8”)
(IS123-16DC) 11-1/8” x 9-1/8” x (16”)
(IS123-59DC) 11-1/8” x 9-1/8” x (33-5/8”~58-1/2”)
2) Recirculating Kit (Sold Separately):
(IS123DCD) 11-1/8” x 9-1/8” x (22-5/8”~36-3/8”)
(IS123-16DCD) 11-1/8” x 9-1/8” x (16”)
(IS123-59DCD) 11-1/8” x 9-1/8” x (33-5/8”~58-1/2”)
DUCT COVER
Two-Piece Adjustable Duct Cover
DIMENSION (W x D x H)
1) Original Kit (Sold Separately):
(IS123DC) 11-3/8” x 9-1/2” x (18-1/8”~37-3/8”)
(IS123-16DC) 11-3/8” x 9-1/2” x (9-1/4”~17-1/2”)
(IS123-59DC) 11-3/8” x 9-1/2” x (30-1/4”~59-1/4”)
2) Recirculating Kit (Sold Separately):
(IS123DCD) 11-3/8” x 9-1/2” x (18-1/8”~37-3/8”)
(IS123-16DCD) 11-3/8” x 9-1/2” x (9-1/4”~17-1/2”)
(IS123-59DCD) 11-3/8” x 9-1/2” x (30-1/4”~59-1/4”)
IS2336SQ IS2342SQ
NET WEIGHT (lbs)
GROSS WEIGHT (lbs)
Hood:
Hood:
53.0
73.0
55.0
77.0
SPEED
Air Capacity (cfm)*
(Original / Recirculating)
Low
Medium
720 / 330
4.5 / 4.5
High
QuietMode
500 / 150
640 / 200
3.0 / 3.0
800 / 400
4.8 / 4.8
Sone (Original / Recirculating)
*In House Test Static Pressure “0”. One sone is equivalent to the sound of a refrigerator at 40 decibels.
1.0* / 1.0*
**Specifications subject to change without notice.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
***All inch measurements are converted from millimeters. Inch measurements are estimated.
***All measurements in ( ) are millimeters.
ORIGINAL KIT (Sold Separately)
MODEL NO.
IS123DC
A
B
DCH
C
D
TSH
MAX. HT.
INTSALLED
36-3/8”
(925)
18-1/8”
(460)
9-1/4”
(235)
30-1/4”
(770)
19-1/4”
(490)
8-1/4”
(210)
29”
37-3/8
(950)
17-1/2”
(445)
59-1/4”
(1505)
14-5/8”
(370)
-
22-5/8”
(575)
-
37-1/4”
(946)
16”
(405)
59-1/4”
(1505)
IS123-16DC
IS123-59DC
16”
(405)
58-1/2”
(1485)
25-5/8”
(650)
33-5/8”
(854)
(735)
DUCT COVER
TELESCOPIC STACK
12
Download from Www.Somanuals.com. All Manuals Search And Download.
RECIRCULATING KIT (Sold Separately)
MODEL NO.
IS123DCD
A
B
DCH
C
D
TSH
MAX. HT.
INTSALLED
36-3/8”
(925)
18-1/8”
(460)
9-1/4”
(235)
30-1/4”
(770)
19-1/4”
(490)
8-1/4”
(210)
29”
37-3/8
(950)
17-1/2”
(445)
59-1/4”
(1505)
14-5/8”
(370)
-
22-5/8”
(575)
-
37-1/4”
(946)
16”
(405)
59-1/4”
(1505)
IS123-16DCD
IS123-59DCD
16”
(405)
58-1/2”
(1485)
25-5/8”
(650)
33-5/8”
(854)
(735)
DUCT COVER
TELESCOPIC STACK
13
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL NO.: IS2336SQ
IS2342SQ
KEY NO. DESCRIPTION
MODEL /SIZE
PART NO.
1
2
3
4
5
Power Cord
C1-0406-0120-01
C1-0505-0001
C1-0708-0006
B101-1242-13
B101-1236-02
B101-1242-02
C1-0202-1242
C1-0402-0120-40
6” Round Plastic Exhaust
Round Head Screw (TS 4 x 6)
Hood Roof
Hood Casing
IS2336SQ
IS2342SQ
6
7
Transformer Bracket
Transformer (Light)
C1-0707-0001
C1-0403-0101
C1-0201-1242
C1-0707-0001
C1-0401-0120-01A
C1-0707-0001
8
Transformer Bracket Screw (3/16” x 3/8”)
Halogen Light (12V 20W Max.)
Transformer Support (Light)
Screw (3/16” x 3/8”)
9
10
11
12
13
Capacitor
Round Head Screw (TS 4 x 6)
14
15
16
17
A
Processor Board Box
Processor Board
Flat Head Screw (M 2 x 8)
Air Chamber
Air Chamber (Top)
Air Chamber (Side)
Motor (Left)
C1-0501-0102
C1-0404-0401-B
C1-0704-0003
C1-0102-1242
C1-0101-1242
C1-0301-0120-07A
C1-0301-0120-08A
C1-0251-0092-01
C1-0251-0092-02
C1-0502-0201
B101-1236-09
B
18
19
20
21
22
23
Motor (Right)
Turbine Impeller (Left)
Turbine Impeller (Right)
Oil Tunnel
Bottom Casing
IS2336SQ
IS2342SQ
B101-1242-09
24
25
Impeller Plastic Cover
Motor Position Screw (3/16” x 5/8”)
C1-0251-0001
C1-0703-0001
26
27
28
29
30
31
Bottom Casing Screw (3/16” x 5/8”)
Transformer Screw (3/16” x 3/8”)
Control Board
Control Unit
Round Head Screw (TS 1/8” x 3/8”)
Transformer (Motor)
C1-0704-0001
C1-0707-0001
C1-0404-0401-A
C1-0501-0101
C1-0708-0003
C1-0402-0120-40
14
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL NO.: IS123DC
ORIGINAL KIT (Sold Separately)
KEY NO. DESCRIPTION
MODEL /SIZE
PART NO.
01
Duct Cover
IS123DC
12-04000-304-51
IS123-16DC
IS123-59DC
12-04016-304-51
12-04059-304-51
C1-0707-0001
02
03
Round Head Screw (3/16” x 3/8”)
Telescopic Stack
IS123DC
IS123-16DC
IS123-59DC
C1-0203-1242-36
C1-0203-1242-16
C1-0203-1242-59
C1-0708-0001
C1-0707-0001
C1-0101-0001
04
05
06
07
A
B
C
D
Round Head Screw (3/16” x 3/8”)
Duct Cover Screw (3 x 8 mm)
Round Head Screw (TS 4 x 6)
Filter Set
Mesh Filter
Safety Screen
IS123F
MF-0201
C1-0604-0201
C1-0602-0202
C1-0503-0201
Oil Container (Round)
C1-0705-0001
Safety Screen Screw
MODEL NO.: IS123DCD
RECIRCULATING KIT (Sold Separately)
KEY NO. DESCRIPTION
MODEL /SIZE
IS123DCD
IS123-16DCD
IS123-59DCD
PART NO.
01
Duct Cover (Recirculating)
12-04000-304-51F
12-04016-304-51F
12-04059-304-51F
C1-0707-0001
C1-0203-1242F36
C1-0203-1242F16
C1-0203-1242F59
C1-0708-0001
02
03
Round Head Screw (3/16” x 3/8”)
Telescopic Stack
IS123DCD
IS123-16DCD
IS123-59DCD
04
05
06
07
A
Round Head Screw (3/16” x 3/8”)
Duct Cover Screw (3 x 8 mm)
Round Head Screw (TS 4 x 6)
Charcoal Filter Set
C1-0707-0001
C1-0101-0001
RH-CF01
MF-0201
Charcoal Filter
C1-0603-0302
C1-0604-0201
C1-0602-0202
C1-0503-0201
C1-0705-0001
B
C
D
E
Mesh Filter
Safety Screen
Oil Container (Round)
Safety Screen Screw
15
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL NO.: IS2336SQ
IS2342SQ
16
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL NO.: IS2336SQ
IS2342SQ
17
Download from Www.Somanuals.com. All Manuals Search And Download.
1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING
DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT.
REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY
TO SUPPORT YOUR CLAIM.
Upon acceptance of items, owner assumes responsibility for its safe arrival. Damages
should be reported to carrier and a claim filed. Failure to do this could result in the carrier
refusing to honor your claim. The carrier will furnish you with necessary forms for filing a
claim.
DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR
WARRANTY.
2. PLEASE INSPECT CONTENTS OF PACKAGE (S) CAREFULLY UPON RECEIVING!
We must be notified in writing of any damages and/or missing parts within the allocated
days upon receipt of package(s). Contact your local KOBE dealer or distributor or call
KOBE for the time limit.
CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS.
NOTE: ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR
FACTORY.
3. Products must be returned in good working condition with ALL original parts and
documentation packed in ALL original cartons, fillers and shipping cartons. A restocking
fee of 25% will be charged for all approved return(s).
EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS
MISSING.
4. MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE
INSTALLATION. Appearance flaws of the hood found after installation and not affecting
hood performance is not covered under our warranty for returns or exchanges. Service
visits not covered under warranty will carry a service charge.
A) Before Installation: Return for exchange or refund (please see above for
acceptable returns).
B) After Installation: NO exchange or refund.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY CERTIFICATE
KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from
defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a
period of two years from the date of purchase and to the repair or replacement at its option and
subject to the terms and conditions stated below, of any component part, which its examination
shall disclose to be so defective.
TWO-YEAR WARRANTY SERVICE PERIOD
Any covered failure occurring within two years of original purchase arising from defective
workmanship or material in manufacture will be repaired (or at our option the unit will be
replaced) free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as
applicable. Keep proof of purchase (or original invoice) handy for inspection.
If the range hood is sold by the original purchaser during the warranty period the new owner is
protected until expiration of the original purchaser’s warranty.
CONDITIONS
The following conditions apply only in relation to the warranty expressly given in this certificate.
1) This warranty applies only:
a) within U.S.A. and Canada.
b) to range hoods used for PRIVATE SINGLE FAMILY USE (if used for COMMERCIAL or
MULTIPLE FAMILY USE or other purposes, warranty will be voided).
2) Repair of any fault to be provided under this warranty shall not be provided:
a) if the identification number attached to the range hood has been altered, rendered
illegible or removed;
b) if notice of the defect has not been given within the period applicable;
c) for failure of light bulbs;
d) for physical damage;
e) for surfaces damaged by use of improper chemical cleaning agents;
f) if the appliance has been:
i) subject to misuse, abuse, negligence, accident, incorrect installation or failure to follow
the operating instructions;
ii) connected to improper, inadequate or faulty electricity service or exhaust ducts or
flues or operated using incorrect or contaminated lubricants;
iii) installed, maintained or operated otherwise than in accordance with the instructions
furnished by KOBE Range Hoods including the improper use of detergents, bleaches,
or cleaners.
g) for damage to range hood during transit, delivery, installation or removal;
h) for damage by or resulting from attempted repairs conducted by anyone other than our
Authorized Service Agent.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
3) The purchaser shall be responsible for any expenses involved in making the range hood
readily accessible for servicing and where the range hood is installed outside the main sales
territory of the retailer or service territory of the nearest approved KOBE Range Hoods Agent
as applicable, for any traveling expenses and any costs of transporting the range hood or
parts thereof to and from the dealer or Service Agent
4) The purchaser must produce proof of purchase together with this warranty certificate when
making the claim.
5) Damages caused during shipment are not covered under our warranty.
CONSEQUENTIAL DAMAGE
The warrantor is not responsible for any consequential damage. SOME STATES DO NOT
ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION
MAY NOT APPLY TO YOU.
IMPLIED WARRANTIES/STATE LAW
Any implied warranties, including the implied warranty of merchantability and fitness for purpose,
imposed on the sale by the laws of the state of sale are limited to two year from the date of
original purchase. Some states do not allow limitations on the duration of implied warranties.
This warranty gives you specific legal rights, and may also have rights, which vary from state to
state.
SERVICE
For service contact:
KOBE Range Hoods, Inc.
4934 Walnut Grove Avenue
Suite 202
San Gabriel, CA 91776
U.S.A
Tel: (626) 309-1356 Fax: (626) 309-1366
Email: [email protected]
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Register Your Product!
Any covered failure occurring within two years of original purchase arising from defective
workmanship or material in manufacture will be repaired or at our option the unit will be
replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods
as applicable. Keep proof of purchase (original invoice) handy for inspection.
If the range hood is sold by the original purchaser during the warranty period the new owner
is protected until expiration of the original purchaser’s warranty. See warranty section for
complete warranty coverage information.
This appliance has been manufactured, tested, and inspected to the standards required by
KOBE Range Hoods.
PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF
PURCHASE TO:
KOBE Range Hoods, Inc.
4934 Walnut Grove Avenue
Suite 202
San Gabriel, CA 91776
RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD:
Model No. ________________________
Serial No. ________________________
Purchased Date
Purchased From:
_____/_____/_____
______________________________
______________________________
______________________________
IMPORTANT: PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY
WHEN REQUESTING FOR SERVICE.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
|