TECHNICAL MANUAL
CKF 50 Hz
Condensing Units
•
•
•
•
Refer to Service Manual RS6100004 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
RT6111009r4
January2012
Copyright © 2007, 2010 - 2012 Goodman Manufacturing Company, L.P.
Copyright © 2007 Goodman Manufacturing Company, L.P.
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
CKF24-2P
CKF36-2P
CKF36-5P
CKF48-5P
CKF60-5P
CKF70-5P
CKF24-2M
CKF24-2N
CKF36-2M
CKF36-2N
CKF36-5M
CKF36-5N
CKF48-5M
CKF48-5N
CKF60-5M
CKF60-5N
CKF70-5M
CKF70-5N
* Indicates minor revision & is not used for order entry or inventory management
NOTE: CKF**-*P* units are shipped without refrigerant and
are pressurized with a nitrogen holding charge. This
charge must be removed and unit evacuated and charged as
per the installation instructions.
The United States Environmental Protection Agency (“EPA”) has issued various regulations re-
garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
WARNING
WARNING
Do not connect or use any device
To prevent the risk of property
WARNING
that is not design certified by
damage, personal injury, or death,
Goodman for use with this unit.
do not store combustible materials or use gasoline or
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
other flammable liquids or vapors in the vicinity of this
appliance.
3
PRODUCT DESIGN
CKF 50 Hz models are available in 2 through 6 ton sizes.
They are designed for 220/240 to 380 volt single phase appli-
cations.
The condenser air is pulled through the condenser coil by a
direct drive propeller fan. This condenser air is then dis-
charged out of the top of the cabinet.
NOT
RECOMMENDED
OK!
B
B
OK!
These units are designed for free air discharge, so no addi-
tional resistance like duct work shall be attached.
B
B
The suction and liquid line connections on present models
are of the sweat type for field piping with refrigerant type cop-
per. Back seating valves are factory installed to accept the
field run copper. The total refrigerant charge for a normal in-
stallation is factory installed in the condensing unit. CKF units
are charged for the matching evaporator coil and a 15 foot [5 m]
refrigerant line set.
A
AA
AA
AA
OK!
C
C
OK!
AA
AA
AA
OK!
OK!
AA
A
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Condi-
tioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has ad-
equate capacity to heat or cool the conditioned space.
C
C
CKF condensing units use a mix of Copeland Reciprocating®
and Copeland Compliant® Scroll compressors. There are a
number of design characteristics which are different from the
scroll compared to the traditional reciprocating compressor.
Model Type
Residential
A
B
C
AA
10 [25]
12 [30]
10 [25]
12 [30]
18 [46]
18 [46]
20 [51]
Due to their design Scroll compressors are inherently more
tolerant of liquid refrigerant.
24 [61]
Light Commercial
Measurements in inches. [ ] Designates metric equivalents.
NOTE: Even though the compressor section of a Scroll com-
pressor is more tolerant of liquid refrigerant, continued flood-
back or flooded start conditions may wash oil from the bear-
ing surfaces causing premature bearing failure.
Copeland Compliant® Scroll compressors use white oil which
is compatible with 3GS. 3GS oil may be used if additional oil
is required.
Special consideration must be given to location of the con-
densing unit(s) in regard to structures, obstructions, other
units, and any/all other factors that may interfere with air
circulation. Where possible, the top of the unit should be
completely unobstructed; however, if vertical conditions re-
quire placement beneath an obstruction there should be a
minimum of 60 in. [152 cm] between the top of the unit
The CKF condensers use new generation scroll compres- and the obstruction(s). The specified dimensions meet re-
quirements for air circulation only. Consult all appropriate regu-
latory codes prior to determining final clearances.
sors. These compressors have an internal equalization mecha-
nism and an anti-counter rotation device which allow the scrolls
to equalize in approximately ½ second at shut down.
Another important consideration in selecting a location for
the unit(s) is the angle to obstructions. Either side adjacent
the valves can be placed toward the structure provided the
side away from the structure maintains minimum service clear-
ance. Corner installations are strongly discouraged.
Operating pressures, amp draws and minimum circuit am-
pacity may differ from standard reciprocating compressors.
This information may be found in the "Cooling Performance
Data" section and should be reviewed prior to installation of
the condenser.
DO NOT locate the unit:
–
–
–
Directly under a vent termination for a gas appliance.
Within 3 feet [1 m] of a clothes dryer vent.
Where the refreezing of defrost water would create a
hazard.
–
Where water may rise into the unit.
CKF**-*P* models are shipped with a nitrogen holding charge only.
4
PRODUCT DESIGN
Dimensions
W
D
H
Model
Dimensions - W x D x H
CKF24-2*
CKF36-2*
CKF36-5*
CKF48-5*
CKF60-5*
26" [660] x 26" [660] x 29¾ [756]
26" [660] x 26" [660] x 29¾ [756]
26" [660] x 26" [660] x 29¾ [756]
29" [737] x 29" [737] x 29¾ [756]
29" [737] x 29" [737] x 32¼ [819]
CKF70-5*
29" [737] x 29" [737] x 38¼ [972]
[ ] Designates metric equivalents
5
CONDENSING UNIT SPECIFICATIONS
Cooling Capacity, BTUH/kW
24600/7.2
34000/10.0
34000/10.0
44000/12.9
55000/16.1
64000/18.8
Compressor
12.50
61.0
17.9
97.4
5.3
42.0
7.4
50.0
9
10.9
101.0
R.L. Amps
74.0
L.R. Amps
410/275
410/275
410/275
410/275
410/275
410/275
High Pressure Switch-Open / Close
Condenser Fan Motor
Horsepower
1/4
1/4
1/4
1/4
1/4
1/3
F.L. Amps
0.9
3/8 [9.6]
3/4 [19.1]
88
0.9
3/8 [9.6]
3/4 [19.1]
89
0.8
3/8 [9.6]
7/8 [22.3]
89
0.8
0.8
3/8 [9.6]
7/8 [22.3]
121
1.2
Liquid Line, Inches [mm] O.D.*
Suction Line, Inches [mm] O.D.*
Refrigerant Charge
Power Supply
3/8 [9.6]
7/8 [22.3]
113
3/8 [9.6]
7/8 [22.3]
153
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Electrical Conduit Size
16.6
25
23.3
40
7.5
15
10
15
12
20
14.8
20
Power Supply (Inches)
(mm)
1/2 or 3/4
[13 or 20]
1/2 or 3/4
[13 or 20]
1/2 or 3/4
[13 or 20]
1/2 or 3/4
[13 or 20]
1/2 or 3/4
[13 or 20]
1/2 or 3/4
[13 or 20]
Approximate Shipping Weight (lbs-[kg])
180 [82]
184 [84]
184 [84]
191 [87]
210 [96]
228 [104]
[ ] Designates metric equivalents
1
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
May use fuses or HACR-type circuit breakers of the same size as noted.
2
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit
breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
CKF**-*P* models are shipped with a nitrogen holding charge only.
6
COOLING PERFORMANCE DATA
CKF24-2*
7
COOLING PERFORMANCE DATA
CKF24-2*
8
COOLING PERFORMANCE DATA
CKF36-2*
9
CKF36-2*
COOLING PERFORMANCE DATA
10
COOLING PERFORMANCE DATA
CKF36-5*
11
COOLING PERFORMANCE DATA
CKF36-5*
12
CKF48-5*
COOLING PERFORMANCE DATA
13
COOLING PERFORMANCE DATA
CKF48-5*
14
CKF60-5*
COOLING PERFORMANCE DATA
15
COOLING PERFORMANCE DATA
CKF60-5*
16
COOLING PERFORMANCE DATA
CKF70-5*
17
COOLING PERFORMANCE DATA
CKF70-5*
18
PERFORMANCE DATA
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and
high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the installation
instructions.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 10 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 5 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
19
WIRING DIAGRAMS
CKF[24-36]M/N/P
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Y L N O R O T A T C N O C E P O L
E L B U O D E T
R N T A L E A
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
20
WIRING DIAGRAMS
CKF[48-70]M/N/P
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
21
|
Agilent Technologies 6843A User Manual
Briggs Stratton Automobile Parts 250000 User Manual
Buhler III User Manual
Cornelius Agitator Motor 569000208 User Manual
Fellowes DS 2 User Manual
Friedrich Air Conditioner US12C30 User Manual
Friedrich SH20L30 User Manual
Fujitsu Air Conditioner ASU12RLS User Manual
GE General Electric Air Conditioner agv18 User Manual
Harbor Freight Tools 03418 User Manual