About This Document  
Abstract  
This document provides descriptions and procedures for the installation and operation of Process Instrument Explorer  
software.  
Contacts  
World Wide Web  
The following lists Honeywell’s World Wide Web sites that will be of interest to our customers.  
Honeywell Organization  
WWW Address (URL)  
Corporate  
Industrial Measurement and Control  
Telephone  
Contact us by telephone at the numbers listed below.  
Organization  
Phone Number  
United States and Canada  
Honeywell  
1-800-423-9883 Tech. Support  
1-800-525-7439 Service  
03/06  
Process Instrument Explorer Configuration Software User Manual  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
iv  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figures  
vi  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
1 Introduction  
1.1 Overview  
Process Instrument Explorer (P.I.E.) lets you configure Honeywell process instruments  
such as controllers and analyzers using a PC (desktop/laptop) or Pocket PC.  
Figure 1-1 Screen capture of Process Instrument Explorer running on a Pocket  
PC  
1.1.1 Features  
Create/edit configurations live, just connect software to controller comm port.·  
Create/edit configurations offline and download later to controller comm port.·  
Communication types available on process instruments:  
Infrared  
RS 485  
Ethernet  
Common look and feel between PC and Pocket PC versions.  
Same communications types on process instruments allow interconnectivity.  
Available in English, Spanish, Italian, German and French.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Introduction  
The infrared connection provides a non-intrusive wireless connection with the  
instrument and maintains NEMA4X AND IP66 integrity.  
No need to get access to the back of the instrument to communicate with the  
instrument, no need to take your screw driver to wire the communication cable, no  
wiring mistake possible. You can now duplicate an instrument’s configuration,  
upload or download a new configuration in a matter of seconds, just by pointing  
your Pocket PC in the direction of the instrument.  
It takes just a few seconds to upload a configuration from an instrument. You can then  
save the configuration file onto your PC or pocket PC for review, modification or  
archiving. Furthermore, this software also gives you important maintenance information  
on the instrument: instantly get information on the current operating parameters, digital  
inputs and alarm status, identify internal or analog input problems.  
2
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
2 Installation  
2.1 System Requirements  
Hardware  
PC  
CPU: Intel x86 processor  
RAM: 32MB  
Disk space: 4.2MB  
For IR Communications: Actisys ACT-IR220L+  
For RS-485 Communications: Technman PC5001 or equivalent RS-232/485 Converter  
For Ethernet Communications: 10 BaseT or 10/100 BaseT Port  
CPU: Intel PXA250/ PXA255 or later  
RAM: 32MB  
Pocket PC  
Pocket PC must have an Infrared Port or an RS485 converter  
Software  
PC  
Windows 2000 SP2, Windows XP SP1, Windows NT SP6  
Pocket PC 2002 or later  
Pocket PC  
Microsoft Active Sync application must be installed for the PC to communicate with the  
Pocket PC through the Active Sync cable.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
2.2 Install/Upgrade Procedure  
Follow this procedure to install, reinstall, or upgrade P.I.E.  
ATTENTION: If upgrading, any P.I.E. databases (that is, saved instrument  
configurations) can be copied to the new P.I.E. application directory. Older databases are  
compatible with newer versions of P.I.E.  
Step  
Action  
1
Insert P.I.E. CD into your PC. Click “Install/Uninstall” from the opening menu.  
Welcome Screen starts off the installation.  
2
3
License agreement details the agreement on which you purchased this software. Continue only  
after reading and agreeing to these terms.  
4
5
Select Platform  
Select the platform on which to install P.I.E.: PC, Pocket PC, or Both.  
Select Version  
This screen appears only if P.I.E. is already installed. Use this screen to reinstall or upgrade your  
software. If no version is already installed then this screen does not appear; go to Step 6.  
To reinstall:  
The upper frame shows the version of the software that can be installed; click Install to reinstall  
the version specified.  
To upgrade:  
The lower frame shows the versions and their languages that are installed. Select a  
version/languages to be upgraded with the version in the upper frame, then select Upgrade.  
Attention: Any P.I.E. databases (that is, saved instrument configurations)  
can be copied. Older databases are compatible with newer versions of  
P.I.E.  
6
PC installation:  
Enter User Name, Serial Number, and License Key  
Enter user name. Enter serial number and license key from the CD cover. Note: numbers  
are case-sensitive.  
Pocket PC installation:  
Microsoft Active Sync application must be installed on the PC and Pocket PC.  
Connect the Pocket PC to the PC with an Active Sync Cable.  
Power up Pocket PC.  
On PC select the Active Sync “Guest Partnership” type connection.  
Enter User Name, Serial Number, and License Key  
Enter user name. Enter serial number and license key from the CD cover. Note:  
characters are case-sensitive.  
4
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Step  
Action  
7
8
Select Language(s)  
Select one or more languages to install. If installing to both the PC and the Pocket PC then the  
software will be first installed in the Pocket PC and then in the PC.  
Choose Destination  
Select a path in which to install the software. Use the default path shown or browse to a different  
path. This screen does not appear if reinstalling over existing version.  
Note: Pocket PC devices do not have drives, so the destination folder should not contain drive  
information. Pocket PC destination folder must start with a “\”.  
9
Select Databases to Copy  
This screen appears only if you previously uninstalled a version and retained the database. (A  
P.I.E. database contains saved instrument configurations.) If no databases were retained this  
screen does not appear, go to Step 10.  
You are shown a list of versions that are currently installed, as well as previously retained  
databases that have been found. You are asked to select the database version you want to copy  
into the newly installed/upgraded version of P.I.E.  
10  
Finalize installation  
PC:  
Shortcut(s) can be installed in the Start Menu of the PC. Shortcuts are named  
“PIE(language)(version)”. For example, “PIEEng1_00” is PIE English 1.00.  
Pocket PC:  
A popup announces that files are being transferred to the Pocket PC. A second popup announces  
that setup is accessing the mobile device.  
The Files will be copied to the directory selected in step 8. When the installation finishes, a  
message box reminds you to check your Pocket PC screen to see if additional steps are  
necessary to complete the installation. If all is ok the Pocket PC tells you the installation is  
complete.  
If your PocketPC has Windows Mobile 5.0 operating system, a popup will indicate that the  
software is from an unknown source. Click yes to proceed with the installation.  
Shortcut(s) will be installed in the Start Menu or Program Group of the Pocket PC. Shortcuts are  
named “PIE(language)(version)”. For example, “PIEEng1_00” is PIE English 1.00.  
11  
Installation/upgrade is finished.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
2.3 Uninstall Procedure  
Follow this procedure to uninstall P.I.E. from your PC or Pocket PC.  
ATTENTION: You must uninstall older versions from your PocketPC before doing an  
upgrade.  
Step  
Action  
1
2
3
Insert P.I.E. CD into your PC. Click “Install/Uninstall” from the opening menu.  
Welcome Screen starts off the procedure.  
License agreement details the agreement on which you purchased this software. Continue only  
after reading and agreeing to these terms.  
4
5
Select Platform  
Select the platform from which to uninstall P.I.E.: PC, Pocket PC, or Both.  
Select Version  
The upper frame shows the version of the software that can be installed or upgraded to; leave as  
is and go to lower frame.  
The lower frame shows the versions and their languages that are installed. Select a  
version/languages to uninstall, then select Uninstall.  
Retain Database?  
If any instrument configurations (that is, a P.I.E. database) exist on your PC or Pocket PC then a  
popup appears asking if you want to retain the database. When given the option to retain  
database:  
Select Yes to save the database for future use if:  
you will install P.I.E. later, or  
you are upgrading your PocketPC with a newer version, or  
you want to archive the database.  
The database location is then shown.  
Or  
Select “No” to delete the database.  
Uninstallation is finished.  
6
6
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3 Operations  
3.1 Overview  
The PC and Pocket PC Operations are virtually identical. Any differences will be  
indicated. Operations choices are:  
Communications Setup—Before uploading or downloading instrument configurations  
you must set up communications.  
Upload Database—Uploads instrument configuration to PC/Pocket PC.  
Offline Configuration—Edits an instrument configuration for later downloading.  
Download—Downloads an instrument configuration to an instrument.  
Online Configuration—Edits and downloads one instrument setting at a time.  
Maintenance Data—Displays key operating parameters and status parameters of the  
instrument without switching between the instrument screens. Some of the information  
presented here is not visible through the instrument display panel. Used primarily for  
diagnostics.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operations  
Table 3-1 Operations Icons  
PC  
Pocket PC  
8
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
Table 3-2 Operations Menu  
PC  
(click Operations)  
Pocket PC  
(tap Menu/Operations)  
03/06  
Process Instrument Explorer Configuration Software User Manual  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.1 Communications Setup  
Before transferring data between P.I.E. and instrument you must set up your PC or  
Pocket PC communication parameters using this procedure.  
Step  
Action  
1
2
Select “Communication Setup” or “PC Comm Setup” icon or menu item.  
Select “Communication type” to be used with the process instrument: Infrared, RS485, or  
Ethernet. The status bar at the bottom of the screen indicates your choice.  
Note 1: Ethernet feature is not supported in Pocket PC.  
Note 2: IPAQ Pocket PCs do not support serial communication.  
“Select Type to set up”  
3
Infrared:  
Device address: Enter address of the process instrument. Default 3.  
Serial Port (PC only): Your PC requires an Infrared cable to communicate with the  
instrument. This cable must be plugged into the PC’s Serial Port. Enter that port  
number here.  
IR Port (Pocket PC only): Your Pocket PC will attempt to automatically determine the  
IR port address during the installation process. If successful, the IR port will be  
automatically set and cannot be changed. If unsuccessful, you must specify the IR  
port address using the drop down menu. Contact Honeywell Technical Support for  
assistance.  
RS485  
Device address: Enter address of the process instrument. Default 3.  
Serial Port (PC only): Your PC requires a RS232/RS485 converter to communicate  
with the instrument. This cable must be plugged into the PC’s Serial Port. Enter that  
port number here.  
Serial Port (Pocket PC only): Your Pocket PC will attempt to automatically determine  
the serial port address during the installation process. If successful, the serial IR port  
will be automatically set and cannot be changed. If unsuccessful, you must specify  
the IR port address using the drop down menu. Contact Honeywell Technical  
Support for assistance.  
Your Pocket PC requires a RS232/RS485 converter to communicate with the  
instrument. This cable must be plugged into the Pocket PC’s Serial Port.  
See your instrument’s manual for wiring details.  
Ethernet  
IP address: Enter instrument’s IP address. Default 10.0.0.2.  
Timeout (1 – 20 sec): Enter number of seconds of non-response before timeout. As  
network traffic increases this will need to be increased.  
Retries (2 to 60): Enter number of attempts to connect. As network traffic increases  
this will need to be increased.  
See your instrument’s manual for wiring details.  
4
Pocket PC only: For Infrared communication, verify that the beam settings checkbox in the  
Pocket PC system software is UNCHECKED. This checkbox is located at:  
Start\Settings\Connections\Beam. Infrared communications will not work with if this box is  
checked.  
10  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.2 Upload  
Upload copies your instrument’s configuration into P.I.E. where it can be saved, edited,  
and downloaded back to the instrument or other instruments.  
Attention Infrared users: Before transferring data between your instrument and  
Step  
Action  
1
2
Select Upload icon or menu item. Upload Configuration box appears.  
Click Start. If using Infrared, first press any instrument button to activate infrared, then aim  
the beam at the instrument, then click Start.  
3
Status of upload (% complete) is shown. Also, at bottom of display a green Transmission  
Status icon flashes during transmission.  
To terminate upload, select Abort. If upload is successful you are given option to save the  
configuration or cancel.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.3 Offline Configuration  
Offline Configuration lets you edit an instrument’s configuration file for later  
downloading to an instrument. . This operation is mostly used during initial configuration  
where the configuration from one instrument is copied, duplicated, or modified and then  
downloaded to other instruments.  
Step  
Action  
1
2
Select “Offline Configuration” icon or menu item.  
Available Device Types (process instruments) are shown. Select Device Type whose  
configuration you want to edit, for example, UDC2500.  
3
Previously saved configurations are shown in the File List.  
Double-click/double-tap a configuration to edit. The prompts are organized exactly as on the  
instrument itself.  
For details on functions and their settings, refer to that instrument’s manual.  
If an analog configuration is highlighted with red text or a digital configuration is shown blank,  
it means that the stored value is now out of range, either because of previous changes to the  
instrument’s configuraton or because of incompatibilities with the configuration set. Change  
the configuration to an in-range setting to correct the error.  
4
Ethernet users have an additional Group: Ethernet & Email. You can set up an email to be  
sent when a rising edge (off-to-on) alarm is detected. Alarm status is checked every 30  
seconds, so only one rising edge will be detected per 30 seconds.  
Attention:  
-In controllers, updates to Ethernet parameters may take up to 60 seconds to take effect.  
After you change the instrument’s IP address, to make it recognized you must execute the  
“arp-d” command at a DOS prompt.  
Ethernet Setup  
IP Address: IP address of the instrument.  
Subnet Mask: Subnet mask of the instrument  
Default Gateway: Default gateway of the instrument  
Email Setup—use the following parameters to configure an email notification during an  
alarm.  
Select Email: Select which email to configure.  
To Email: Enter email address of person to be emailed  
SMTP Address (for outgoing): Enter exchange server address  
From Email: This is the e-mail ID that appears in the “From” field when the recipient  
receives an e-mail from the instrument. It can be any e-mail ID of the user’s choice,  
basically to help identify the device. (e.g: [email protected])  
Select Alarm: Select an alarm whose activation will send the email. To select none, click  
on the highlighted alarm.  
Email Subject: Enter email subject text.  
5
To view or edit a configuration’s Properties, in the File List right-click on the File name (PC)  
or select “Properties” (Pocket PC).  
-
-
-
-
-
-
File name  
Device type  
Uploaded date and time  
Last modified date and time  
Author name  
Description  
12  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.4 Download  
Download sends your P.I.E. instrument configuration to the instrument.  
Attention Infrared users: Before transferring data between your instrument and  
Step  
Action  
1
2
Select Download icon or menu item.  
Available Device Types (process instruments) are shown. Select Device Type whose  
configuration you want to download, for example, UDC2500.  
3
Previously saved configurations are shown in the File List.  
Double-click/double-tap a configuration to be downloaded.  
4
5
Click Start. If using Infrared, first press any instrument button to activate infrared, then aim  
the beam at the instrument, then click Start.  
If the configuration being downloaded includes a change to the instrument’s address (that is,  
Infrared/RS4585 device address and/or Ethernet IP address) then a popup asks you if you  
want to overwrite the address(s). This helps protect against mismatched addresses between  
instrument and the configuration in P.I.E..  
Attention:  
-In controllers, updates to Ethernet parameters may take up to 60 seconds to take effect.  
After you change the instrument’s IP address, to make it recognized you must execute the  
“arp-d” command at a DOS prompt.  
6
Status of download (% complete) is shown. Also, at bottom of display a green Transmission  
Status icon flashes if transmission is normal.  
To terminate download, select Abort. If download is successful you are given option to Close  
the dialog box.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.5 Online Configuration  
Online Configuration lets you upload an instrument configuration and write one change  
at a time back to the instrument. This is useful for tuning your instrument and is faster  
than downloading the entire configuration. For multiple changes consider doing offline  
configuration.  
Step  
Action  
1
2
Select “Online Configuration” icon or menu item.  
Click/tap Start to begin upload. If using Infrared, first press any instrument button to activate  
infrared, then aim the beam at the instrument, then click Start.  
3
Status of upload (% complete) is shown. Also, at bottom of display a green Transmission  
Status icon flashes during transmission.  
To terminate upload, select Abort. If upload is successful you are given option to save the  
configuration or cancel.  
If upload was successful the configuration will appear.  
4
5
Select a Group and edit a Function. For details on functions and their settings, refer to that  
instrument’s manual. If an analog configuration is highlighted with red text or a digital  
configuration is shown blank, it means that the value read up from the instrument is now out  
of range, either because of previous changes to the instrument’s configuraton or because of  
incompatibilities with a downloaded configuration set. Change the configuration to an in-  
range setting to correct the error.  
6
Ethernet users have an additional Group: Ethernet & Email. You can set up an email to be  
sent when a rising edge (off-to-on) alarm is detected. Alarm status is checked every 30  
seconds, so only one rising edge will be detected per 30 seconds.  
Attention:  
-In controllers, updates to Ethernet parameters may take up to 60 seconds to take effect.  
-After you change the instrument’s IP address, to make it recognized you must execute the  
“arp-d” command at a DOS prompt.  
Ethernet Setup  
IP Address: IP address of the instrument.  
Subnet Mask: Subnet mask of the instrument.  
Default Gateway: Default gateway of the instrument.  
Email Setup—use the following parameters to configure an email notification during an  
alarm.  
Select Email: Select which email to configure.  
To Email: Enter email address of person to be emailed.  
SMTP Address (for outgoing): Enter exchange server address.  
From Email: This is the e-mail ID that appears in the “From” field when the recipient  
receives an e-mail from the instrument. It can be any e-mail ID of the user’s choice,  
basically to help identify the device. (e.g: [email protected])  
Select Alarms: Select an alarm whose activation will send the email.  
Email Subject: Enter email subject text.  
7
8
Select Write to download the edit to the instrument. Display indicates if write was successful  
another function. ATTENTION! No warning is given if you overwrite address info (IP,  
Subnet Mask, Gateway) so be aware of what you are doing!  
Close window. You are given the option to save the changed configuration for later use in  
P.I.E.  
14  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.6 Maintenance Data  
Maintenance Data displays key operating parameters and status parameters of the  
instrument without switching between the instrument screens. Some of the information  
presented here is not visible through the instrument display panel. Used primarily for  
diagnostics.  
Step  
Action  
1
2
Select “Maintenance Data” icon or menu item to. If using Infrared, first press any instrument  
button to activate infrared, then aim the beam at the instrument, then select Maintenance  
Data.  
A window appears with maintenance data such as loops, alarms, events. If using RS485 or  
Ethernet the data is refreshed automatically. If using infrared you must refresh manually.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.7 Infrared checklist  
Check the following before using infrared communications.  
Infrared transmitter (Cable or Pocket PC)  
-
-
The Infrared transmitter is pointed directly at the process instrument’s Infrared port.  
The Infrared transmitter is located no more than 0.3 meters (1 foot) away from the  
process instrument.  
Process instrument:  
-
The process instrument is configured with an Infrared port (Infrared on the UDC2500  
is optional; Non Infrared units can be configured using the test jack port, RS485 or  
Ethernet).  
-
-
-
-
The process instrument’s device address must match the device address in the P.I.E.  
Communications Setup.  
The process instrument’s Infrared port must be enabled through its communications  
menu.  
Any button must be pressed on the process instrument to enable the Infrared port for  
4 minutes.  
There are no obstructions between the Infrared transmitter and the process  
instrument.  
P.I.E.:  
-
There is only one process instrument with the device address selected in the P.I.E.  
Communication Setup.  
-
The communications mode in the P.I.E. application must be set to Infrared. (Verify  
by looking at mode displayed in lower left corner of P.I.E. display.)  
Pocket PC:  
-
IMPORTANT: The beam checkbox in the Pocket PC must be unchecked. See  
Start\Settings\Connection\Beam. Infrared communications will not work if box is  
checked.  
-
A valid IR port address has been assigned through the Infrared Communications  
Setup screen.  
-
-
Dell X5 Pocket PCs require a patch from the Dell website.  
Dell X3 Pocket PCs may require a patch from the Dell website.  
16  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operations  
3.1.8 Ethernet Q&A  
Q: How can I find the address of my Honeywell instrument?  
A: The Ethernet address information that has been set in the instrument can be retrieved  
by using P.I.E. to upload a product configuration upload using IR communication. After  
the upload you can view the Ethernet group and see the Ethernet information. An  
alternate way is to use P.I.E. and initiate an online configuration through IR  
communication. This function does an initial upload of the current configuration from the  
instrument and displays the groups. The Ethernet information can be viewed from the  
Ethernet group.  
The above cannot be done through RS485 communication because when the Ethernet  
board is plugged in, the RS485 option is not available.  
The default Ethernet information for a UDC as shipped from the factory is IP 10.0.0.2,  
Mask 255.255.255.0, Gateway 0.0.0.0.  
Q: How do I know what IP Address to use?  
A: The default IP address provided from the factory is 10.0.0.2 on the UDC. Since IP  
addresses must be unique, you will need reset the IP address for multiple instruments or  
if the instrument is going to be placed on a LAN. Multiple instruments on a local net  
could be set at 10.0.0.2, 10.0.0.3, 10.0.0.4, etc. If you want to put the instrument on a  
LAN, you need to obtain available IP addresses from your IT group.  
Q: How do I know what Mask to use?  
A: The mask on the UDC is normally set to 255.255.255.0 since the first (3) numbers in  
the IP address are typically the same for instruments on the same subnet.  
Q: How do I know what Gateway to use?  
A: The gateway information is the IP address of the router which would route the TCP/IP  
traffic to the appropriate destination IP address. Every network has a gateway routing  
device that holds the routing table for that network which specifies how to route TCP/IP  
packets between network devices.  
In the P.I.E. and UDC case, if the PC on which the P.I.E. is running and UDC are  
connected to a LAN, then the gateway should have the IP Address of the router that  
manages the LAN subnetwork. In the case of the PC on which the P.I.E. is running being  
connected directly to the UDC with a crossed Ethernet cable, then the gateway IP address  
can be set to "0.0.0.0". The normal procedure is to copy the first three bytes of the IP  
address from the PC and set the last byte to 1. For example, if the IP address of the PC is  
set to 10.2.3.4 then set the gateway IP address to be 10.2.3.1.  
Q: How do I know what SMTP address to use?  
A: The SMTP address is used for outgoing emails. This address is specific to your LAN  
configuration and can be obtained from your IT group.  
Q: Why can’t I communicate with my controller after I changed the controller’s IP  
address?  
A: The arp table in your desktop PC needs to be reset by typing “arp-d” in the DOS  
command window. Also, changes to Ethernet parameters may take up to 60 seconds to  
take effect.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Services  
4 Services  
4.1 Overview  
Services lets you manage your files through the following menus.  
4.1.1 Pocket PC Services Menu  
Transfer Configuration - Lets you copy device configurations saved in the Pocket PC  
to the PC. Transferred files may then be opened, edited, saved and downloaded from the  
PC.  
Manage Configuration Files - Lets you copy, delete, rename and view the properties of  
saved configuration files.  
Transfer Healthwatch Data For future release. This feature transfers Healthwatch  
data to the desktop PC. Available only for the UDC3500 controller.  
Enable Descriptive Name Support - When enabled, Descriptive Name uses 16  
characters to describe your configuration groups, functions and parameters in more detail  
than the instrument’s 8-character display. The descriptive names come from the  
descriptive file).  
Import Database – Lets you add all or part of another database to your current  
configuration database. You may import configurations created on other PCs and Pocket  
PCs.  
Export Database – Lets you save all or part of the current database so that it may later  
be imported.  
4.1.2 PC Services Menu  
Export Configuration - Lets you write a configuration file to a .csv formatted file which  
can be read into spreadsheet software.  
Transfer Configuration - Lets you copy device configurations saved in the PC to the  
Pocket PC application. Transferred files may then be opened, edited, saved and  
downloaded from the Pocket PC.  
Manage Configuration Files - Lets you copy, delete, rename and view the properties of  
saved configuration files.  
Install Descriptive File - Lets you attach a new 16-character descriptive file to the  
desktop/laptop tool. Descriptive files are specific to instrument version and type. See  
Enable Descriptive Name Support.  
Transfer Descriptive File - Lets you transfer a new 16-character descriptive file from  
the desktop/laptop to the Pocket PC. (Descriptive files are provided by Honeywell.) See  
Enable Descriptive Name Support.  
18  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Services  
Enable Descriptive Name Support – When enabled, Descriptive Name uses 16  
characters to describe your configuration groups, functions and parameters in more detail  
than the instrument’s 8-character display. The descriptive names come from the  
descriptive file.  
Import Database – Lets you add all or part of another database to your current  
configuration database. You may import configurations created on other PCs and Pocket  
PCs.  
Export Database – Lets you save all or part of the current database so that it may later  
be imported.  
Table 4-1 Service menu  
PC Services menu  
Pocket PC Services menu  
(click “Services”)  
(tap “Menu/Services”)  
03/06  
Process Instrument Explorer Configuration Software User Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Services  
4.2 Export Configuration (PC only)  
Export Configuration lets you write a configuration file to a .CSV formatted file which  
can be read into spreadsheet software.  
Step  
Action  
Select Export Configuration from the Services menu.  
Select device (instrument) type.  
1
2
3
4
5
Select configuration to be exported.  
Enter destination and name of exported file.  
Click Export. A popup confirms whether the export was successful.  
4.3 Transfer Configuration  
Transfer Configuration lets you copy configurations between the Pocket PC and the PC.  
Transferred files may then be opened, edited, saved and downloaded.  
Before proceeding:  
Microsoft Active Sync must be installed on the Pocket PC.  
Connect the Pocket PC to the PC with an Active Sync Cable.  
Power up Pocket PC.  
On PC, if Active Sync dialog box appears select “Guest Partnership” type  
connection.  
Step  
Action  
Select Transfer Configuration from the Services menu.  
Select device (instrument) type.  
1
2
3
4
Select configuration(s) to be transferred. Click Next.  
Click Transfer. A popup confirms whether the transfer was successful.  
20  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Services  
4.4 Manage Configuration Files  
Lets you copy, delete, rename and view the properties of saved configuration files.  
Step  
Action  
Select Manage Configuration Files/Manage Files from the Services menu.  
Select device (instrument) type.  
1
2
3
4
Select configuration. Click on headings to sort.  
Pocket PC users must first select File to access the following items.  
Copy: Select to make a copy of the file. Enter new file name.  
Delete: Select to delete the file.  
Rename: Select to rename the file.  
Properties: Select to view or edit the following:  
-
-
-
-
-
-
File name  
Device type  
Uploaded date and time  
Last modified date and time  
Author name  
Description  
4.5 Install Descriptive File (PC only)  
Lets you attach a new 16-character descriptive file to the desktop/laptop tool.  
(Descriptive files are provided by Honeywell.) See Enable Descriptive Name Support.  
Step  
Action  
1
2
Select Install Descriptive File from the Services menu.  
Browse to the new file. These files will be sent by factory or through the internet or email.  
Select the file from the location it was saved after downloading it from the internet or email;  
there is no specific extension for descriptive files. P.I.E. will verify whether the selected file is  
valid.  
03/06  
Process Instrument Explorer Configuration Software User Manual  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Services  
4.6 Transfer Descriptive File (PC only)  
Lets you transfer a new 16-character descriptive file from the desktop/laptop to the  
Pocket PC. (Descriptive files are provided by Honeywell.) See Enable Descriptive Name  
Step  
Action  
1
2
Select Transfer Descriptive File from the Services menu.  
Browse to the new file. These files will be sent by factory or through the internet or email.  
Select the file from the location it was saved after downloading it from the internet or email;  
there is no specific extension for descriptive files. P.I.E. will verify whether the selected file is  
valid.  
4.7 Transfer Healthwatch Data (Pocket PC only, UDC3500 only)  
For future release. Lets you transfer an instrument’s previously saved Healthwatch data  
from the Pocket PC to the desktop/laptop. This data is saved with .CSV (Comma  
Separated Values) extension. Since the Pocket PC does not have a .CSV file viewer and  
it cannot be opened in Pocket Excel, the saved .CSV file can be transferred to the  
Desktop PC and viewed through any of the standard viewers that support .CSV format.  
Step  
Action  
Select Transfer Healthwatch Data from the Services menu.  
Browse to the Healthwatch file you want to transfer.  
Default file is "UDCXXXXvNN_HWm.csv" where:  
1
2
XXXX is device model (2500)  
NN is firmware version (01,02,...)  
m is m'th instance of the healthwatch saved.  
You will have the choice to modify this name.  
Example: UDC2500v01_HW2.csv would be the default name for the second instance of the  
Healthwatch file when saved for a 2500 unit with firmware version '01'.  
4.8 Enable Descriptive Name Support  
When enabled, Descriptive Name uses 16 characters to describe your configuration  
groups, functions and parameters in more detail than the instrument’s 8-character display.  
The descriptive names come from the descriptive file.  
Step  
Action  
1
2
To enable, check Enable Descriptive Name Support from the Services menu. Groups,  
functions and parameters will be displayed in detail.  
To disable, uncheck. Groups, functions and parameters will be displayed in abbreviated  
form.  
22  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Services  
4.9 Import Database  
Lets you add all or part of another database to your current configuration database. You  
may import configurations created on other PCs and Pocket PCs.  
Step  
Action  
1
2
3
4
Enter the name of the database you wish to import using the Browse function. (The file  
format for Process Instrument Explorer databases is *.Nge)  
If you wish to import the entire database, select the “Import Entire Database” checkbox, then  
skip to Step 5.  
If you wish to import part of the database, select the Device Type representing the  
configurations you wish to import (for example, UDC2500).  
To add the files you wish to import to the Selected Configurations to Import list, highlight the  
desired configurations in the left column and press the “Add >” button. You may also use the  
“Add All >>” button to transfer all of the configuration(s) for the current device type into the  
Selected Configuration List.  
To remove configurations from the Selected Configurations to Import list, highlighti a  
configuration in the right column and press the “< Remove” button. You may also use the <<  
Remove All” button to remove all of the configurations from the Selected Configurations to  
Import list.  
5
Press the Import button to add the configurations appearing in the Selected Configurations to  
Import list to your current database. (Note that if the “Import Entire Database” checkbox is  
selected, no files will be shown in the Selected Configurations to Import list)  
03/06  
Process Instrument Explorer Configuration Software User Manual  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Services  
4.10Export Database  
Lets you save all or part of the current database so that it may later be imported.  
Step  
Action  
1
2
Select the Device Type for configuration(s) you wish to Export (for example, UDC2500).  
If you wish to export the entire database, select the “Export Entire Database” checkbox, then  
skip to Step 5.  
3
4
If you wish to export part of the database, select the Device Type representing the  
configurations you wish to export.  
To add the files you wish to export to the Selected Configurations to Export list, highlight the  
configuration in the left column and press the “Add >” button. You may also use the “Add All  
>>” button to transfer all of the configuration(s) for the current device type into the Selected  
Configurations to Export list.  
To remove configurations from the Selected Configurations to Export list, highlight a  
configuration in the right column and press the “< Remove” button. You may also use the <<  
Remove All” button to remove all of the configurations from the Selected Configurations to  
Export list.  
5
6
Enter the name of the database file you wish to create by typing the path\filename or using  
the Browse function. Once a path is selected a default filename of ExportNgcDB.nge  
appears. You may change the filename by overwriting the default.  
Press the Export button to create a new database file containing the configurations listed on  
the Selected Configurations to Export list.  
24  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
5 Index  
alarm  
email, 12, 14  
Communications setup, 10  
Device Types, 12, 13  
Download, 13  
menu, 9  
Offline Configuration, 12  
Online Configuration, 14, 15  
Upload, 11  
PC Comm Setup, 10  
email, 12, 14  
Properties, 12  
Enable Descriptive Name Support, 22  
Ethernet  
Services, 18  
Enable Descriptive Name Support, 22  
Export Configuration, 20  
Export Database, 24  
Q&A, 17  
Ethernet & Email, 12, 14  
Export Configuration, 20  
Export Database, 24  
Import Database, 23  
Infrared checklist, 16  
Install Descriptive File, 21  
Install/Upgrade, 4  
Manage Configuration Files, 21  
Offline Configuration, 12  
Online Configuration, 14, 15  
Operations, 7  
Import Database, 23  
Install Descriptive File, 21  
Manage Configuration Files, 21  
Transfer Configuration, 20  
Transfer Descriptive File, 22  
Transfer Healthwatch Data, 22  
System Requirements, 3  
Transfer Configuration, 20  
Transfer Descriptive File, 22  
Transfer Healthwatch Data, 22  
Uninstall, 4, 6  
Communications setup, 10  
Download, 13  
Upload, 11  
icons, 8, 19  
03/06  
Process Instrument Explorer Configuration Software User Manual  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Sales and Service  
6 Sales and Service  
For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one  
of the offices below.  
794027/ 792198  
CANADA  
Honeywell Limited  
The Honeywell Centre  
300 Yorkland Blvd.  
Toronto, Ontario  
M2j 1s1  
Canada  
Tel.: 800 461 0013  
Fax:: 416 502 5001  
Tel. : 36 1 451 43 00  
Tel. : 351 1 424 50 00  
Tel. : 421 7 52 47 400/425  
ARGENTINA  
Honeywell S.A.I.C.  
Belgrano 1156  
Buenos Aires  
Argentina  
Tel. : 54 1 383 9290  
ICELAND  
REPUBLIC OF IRELAND  
HONEYWELL  
Unit 1  
Robinhood Business  
Park  
Robinhood Road  
DUBLIN 22  
Republic of Ireland  
Tel. : 353 1 4565944  
SPAIN  
HONEYWELL S.A  
Factory  
Josefa Valcarcel, 24  
28027 MADRID  
SPAIN  
HONEYWELL  
Hataekni .hf  
Armuli 26  
PO Box 8336  
128 reykjavik  
Iceland  
ASIA PACIFIC  
Honeywell Asia  
Pacific Inc.  
Room 3213-3225  
Sun Kung Kai Centre  
N° 30 Harbour Road  
Wanchai  
Tel. : 34 91 31 3 61 00  
Tel : 354 588 5000  
SWEDEN  
CZECH REPUBLIC  
HONEYWELL, Spol.S.R.O.  
Budejovicka 1  
140 21 Prague 4  
Czech Republic  
ITALY  
HONEYWELL A.B.  
S-127 86 Skarholmen  
STOCKHOLM  
SWEDEN  
Tel. : 46 8 775 55 00  
HONEYWELL S.p.A.  
Via P. Gobetti, 2/b  
20063 Cernusco Sul  
Naviglio  
REPUBLIC OF  
SINGAPORE  
HONEYWELL PTE LTD  
BLOCK 750E CHAI  
CHEE ROAD  
Hong Kong  
Tel. : 852 829 82 98  
Tel. : 42 2 6112 3434  
ITALY  
AUSTRALIA  
Tel. : 39 02 92146 1  
06-01 CHAI CHEE IND.PARK  
1646 SINGAPORE  
REP. OF SINGAPORE  
Tel. : 65 2490 100  
SWITZERLAND  
HONEYWELL A.G.  
Hertistrasse 2  
8304 WALLISELLEN  
SWITZERLAND  
Honeywell Limited  
5 Thomas Holt Drive  
North Ryde Sydney  
Nsw Australia 2113  
Tel. : 61 2 353 7000  
DENMARK  
HONEYWELL A/S  
Automatikvej 1  
DK 2860 Soeborg  
DENMARK  
MEXICO  
HONEYWELL S.A. DE  
CV  
AV. CONSTITUYENTES  
900  
COL. LOMAS ALTAS  
11950 MEXICO CITY  
MEXICO  
Tel. : 41 1 831 02 71  
REPUBLIC OF SOUTH  
AFRICA  
HONEYWELL  
Southern Africa  
PO BOX 138  
Milnerton 7435  
REPUBLIC OF SOUTH  
AFRICA  
Tel. : 45 39 55 56 58  
AUSTRIA  
Honeywell Austria  
G.M.B.H.  
Handelskai 388  
A1020 Vienna  
Austria  
TURKEY  
FINLAND  
HONEYWELL OY  
Ruukintie 8  
FIN-02320 ESPOO 32  
FINLAND  
Tel. : 358 0 3480101  
HONEYWELL A.S.  
Caryiryolu Sok No. 7  
Ucgen Plaza, Kat 5-6-7  
Icerenkoy 81120 Instanbul  
Turkey  
Tel : 52 5 259 1966  
THE NETHERLANDS  
HONEYWELL BV  
Laaderhoogtweg 18  
1101 EA AMSTERDAM  
ZO  
Tel. : 43 1 727 800  
Tel. : 27 11 805 12 01  
Tel (90-216) 575 66 00  
BELGIUM  
FRANCE  
ROMANIA  
HONEYWELL Office  
Bucharest  
147 Aurel Vlaicu Str.,  
Sc.Z.,  
Apt 61/62  
R-72921 Bucharest  
ROMANIA  
Tel : 40-1 211 00 76/  
211 79  
UNITED KINGDOM  
HONEYWELL  
Honeywell House  
Arlington Business Park  
Bracknell,  
Berkshire  
RG12 1EB  
Tel: +44 (0) 1344 656000  
Honeywell S.A.  
3 Avenue De Bourget  
B-1140 Brussels  
Belgium  
HONEYWELL S.A.  
Bâtiment « le Mercury »  
Parc Technologique de St  
Aubin  
Route de l’Orme  
(CD 128)  
91190 SAINT-AUBIN  
FRANCE  
Tel. from France:  
01 60 19 80 00  
From other countries:  
33 1 60 19 80 00  
THE NETHERLANDS  
Tel : 31 20 56 56 911  
Tel. : 32 2 728 27 11  
NORWAY  
HONEYWELL A/S  
Askerveien 61  
PO Box 263  
N-1371 ASKER  
NORWAY  
BRAZIL  
HONEYWELL DO  
Brazil  
And Cia  
Rua Jose Alves Da  
Chunha  
Lima 172  
Butanta  
05360.050 Sao Paulo  
Sp  
Brazil  
U.S.A.  
HONEYWELL INC.  
INDUSTRIAL PROCESS  
CONTROLS  
1100 VIRGINIA DRIVE  
PA 19034-3260  
FT. WASHINGTON  
U.S.A.  
Tel. : 47 66 76 20 00  
RUSSIA  
HONEYWELL INC  
4 th Floor Administrative  
Builiding of AO "Luzhniki"  
Management  
24 Luzhniki  
119048 Moscow  
RUSSIA  
POLAND  
GERMANY  
HONEYWELL Sp.z.o.o  
UI Domaniewksa 41  
02-672 WARSAW  
POLAND  
HONEYWELL AG  
Kaiserleistrasse 39  
D-63067 OFFENBACH  
GERMANY  
Tel. : 1-800-343-0228  
Tel. : 55 11 819 3755  
Tel. : 48 22 606 09 00  
Tel. : 49 69 80 64444  
Tel : 7 095 796 98 00/01  
VENEZUELA  
BULGARIA  
PORTUGAL  
HONEYWELL  
HONEYWELL CA  
APARTADO 61314  
1060 CARACAS  
VENEZUELA  
HONEYWELL EOOD  
14, Iskarsko Chausse  
POB 79  
BG- 1592 Sofia  
BULGARIA  
HUNGARY  
HONEYWELL Kft  
Gogol u 13  
H-1133 BUDAPEST  
HUNGARY  
SLOVAKIA  
PORTUGAL LDA  
Edificio Suecia II  
Av. do Forte nr 3 - Piso 3  
2795 CARNAXIDE  
PORTUGAL  
HONEYWELL Ltd  
Mlynske nivy 73  
PO Box 75  
820 07 BRATISLAVA 27  
SLOVAKIA  
Tel. : 58 2 239 0211  
Tel : 359-791512/  
26  
Process Instrument Explorer Configuration Software User Manual  
03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
03/06  
Process Instrument Explorer Configuration Software User Manual  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Industrial Measurement and Control  
Honeywell  
1100 Virginia Drive  
Fort Washington, PA 19034  
51-52-25-131 Rev. 03/06 Printed in USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Marine Heating System 309525G User Manual
Hamilton Beach Iron 840172800 User Manual
Hamilton Beach Slow Cooker 33967C User Manual
Hamilton Beach Waffle Iron 26020 User Manual
Heatcraft Refrigeration Products Refrigerator H IM 79E User Manual
Honeywell Door RPWL200A User Manual
HP Hewlett Packard Stereo Equalizer 70205A User Manual
Humminbird Fish Finder 967C User Manual
Hypertec Carrying Case TANCD3HY User Manual
iHome Clock Radio IP23 User Manual