75 GALLON ULTRA LOW NOx
SUPPLEMENT TO INSTRUCTION MANUAL
P/N 238-47759-00
MINIMUM CLEARANCES
(Replaces pg. 8 in instruction manual)
WARNING
Failure to adhere to these installation and operating instructions may
create a hazard to life and property and will nullify the warranty.
This installation must allow access to the front of the water heater and
adequate clearance must be provided for servicing and operating this water
heater. The water heater may be installed on either a combustible or non-
combustible floor. If the water heater is to be installed directly on carpeting, it
must be installed on top of a metal or wood panel (or equivalent) extending
beyond the full width and depth of the appliance by at least three (3) inches
(7.6 cm) in any direction or, if the appliance is to be installed in an alcove or
closet, the entire floor must be covered by the panel. If the rating plate or
the label on the front of the water heater specifies minimum clearances
less than those listed in the below table, the water heater may be
installed in accordance with the minimum clearances listed on the rating
plate or the label on the front of the water heater.
If it is necessary to install this water heater in an alcove, use the clearances
listed in the following table and Figure 1.
Figure 1
238-49945-00B REV 6/12
Download from Www.Somanuals.com. All Manuals Search And Download.
BURNER FLAME CHECKS (Replaces pg. 21 of instruction manual)
These models are equipped with self-adjusting air mixture and do not
have an adjustable air shutter. At periodic intervals, a visual check of the
main burner and pilot flames should be made to determine if they are burning
properly. The main burner flame should light smoothly from the pilot. The
burner flame should be soft and undefined. After five minutes of burner
operation the burner face should be glowing orange and emitting an orange
flame.
Figure 6
3
Download from Www.Somanuals.com. All Manuals Search And Download.
(Replaces pg. 24 of instruction manual)
Manufactured under one or more of the following U.S. Patents: RE.34,534;
B1 5,341,770; 4,416,222; 4,628,184; 4,669,448; 4,672,919; 4,808,356; 4,829,983;
4,861,968; 4,904,428; 5,000,893; 5,023,031; 5,052,346; 5,081,696; 5,092,519;
5,115,767; 5,199,385; 5,277,171; 5,372,185; 5,485,879; 5,574,822; 5,596,952;
5,660,165; 5,682,666; 5,761,379; 5,943,984; 5,954,492; 5,988,117; 6,142,216;
6,395,280; 6,684,821; 7,063,132; 7,007,748
Other U.S. and Foreign patent applications pending. Current Canadian Patents:
1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,092,105; 2,107,012; 2,108,186;
2,112,515
Complete the following information and retain for future reference:
Model No:
Serial No:
Service Phone
Days:
Nights:
Address:
Supplier:
Supplier Phone No:
Figure 7
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST AND DRAWING
(Replaces pg. 27 of instruction manual)
PART NAME AND DESCRIPTION
15. Drain Valve
1. Draft Diverter
2. Jacket Head Pan
16. Gas Control Valve
3. Jacket
17. Manifold Bracket
4. Outer Door
18. Re-Settable Thermal Switch Wire Harness
5. NIpple-Hot Water Outlet
6. Flue Baffle Assembly
7. Dip Tube-Cold Water Inlet
8. Temperature and Pressure Relief Valve
9. Glass Lined Tank
19. Burner Assembly
20. Re-settable Thermal Switch
21. Burner Assembly Cover
22. Gas Feedline
23. Orifice
10. Heat Radiation Shield
11. Foam Insulation
24. Thermopile Wire
25. Igniter Wire
12. Combustion Chamber Assembly
13. Jacket Base Pan
26. Pilot Gas Feedline
27. Pilot Assembly
14. Inner Door Assembly
14A. #8 x ¾ screw
28. Magnesium Anode-Hex Head
5
Download from Www.Somanuals.com. All Manuals Search And Download.
THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF:
GAS WATER HEATERS SUITABLE FOR WATER (POTABLE)
HEATING AND SPACE HEATING
(Replaces pg. 28 of instruction manual)
1. All piping components connected to this water heater for space heating
applications must be suitable for use with potable water. In
Massachusetts, space heating piping length must not exceed 50 feet.
2. Toxic chemicals, such as those used for boiler treatment, must not be
introduced into potable water used for space heating.
3. This water heater must not be connected to an existing heating system
or component(s) previously used with a non-potable water heating
appliance.
4. When the system requires water for space heating at temperatures higher
than required for other means, such as an ASSE approved mixing valve
must be installed to temper the water for those uses in order to reduce the
scald hazard potential.
Please refer to the illustrations below for the suggested piping arrangement.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
7
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|