Introduction  
Thank you for selecting the Honeywell Semi-Professional Weather Station. This compact and easy-to-use product uniquely  
measures and monitors weather data right at your immediate location. It includes a wide range of weather features plus  
precise atomic time and perpetual calendar. Weather measurements include: air temperature, relative humidity, barometric  
pressure, wind speed and direction, rainfall levels and more.  
Standard Package Contents  
In this package you will find:  
One Main Unit (receiver) (TE821WD)  
One Rain Gauge (remote rain sensor/transmitter) (TS906)  
One Anemometer (remote wind sensor/transmitter) (TS805)  
One Three-Channel Temperature & Humidity Sensor (transmitter) (TS33C)  
One 7.5V AC/DC Adapter  
Anemometer Mounting Hardware with wrench tool  
One User Manual  
Required for installation (not included)  
-
-
-
Small Phillips screwdriver  
Anemometer mounting pole  
Small paper clip to reset sensors  
NOTE: If any items are missing or damaged, please contact Hideki Electronics Customer Service before proceeding with  
installation.  
Installation  
The Honeywell Semi-Professional Weather Station operates at 433MHz radio frequency, so no wire installation is required  
between the main unit (receiver) and the remote weather sensors (transmitters). The remote weather sensors include (1)  
thermo-hygrometer (temperature and humidity) sensor, anemometer (wind sensor) and a rain gauge (rain sensor). All data  
measured by these remote sensors is transmitted to the main unit wirelessly, with the operating range from 100 feet to up to  
328 feet (100 meters) in the open area. The Anemometer and the Rain Gauge must be placed outdoors to measure weather  
elements. Remote Thermo-Hygrometer can be placed indoors or outdoors. If you intend measuring outdoor temperature and  
humidity, place the remote sensor outdoors, preferably not in the direct sunlight.  
Before you begin  
The components of this Honeywell Semi-Professional Wireless Weather Station operate at 433MHz radio frequency. No  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
interconnecting wires are required between the main unit (receiver) and the remote sensors (transmitters).  
Power up and test communications between all of the sensors and the main unit BEFORE mounting them outside.  
For most applications alkaline batteries are acceptable where temperatures remain above 32°F (0°C).  
At temperatures below 32ºF(0ºC) use lithium batteries otherwise transmission performance will be reduced or  
interrupted  
Avoid using rechargeable batteries. (Rechargeable batteries do not provide correct power levels).  
ALWAYS install batteries in the remote sensors before the main unit. (Please read batteries installation instructions in  
the manual for each remote sensor before installation)  
Insert batteries matching the polarity in the battery compartment  
Remove plastic sleeve from LCD display (if any).  
During an initial setup, place the main unit close to the remote sensors.  
After reception is established (all of the remote readings will appear on the main units display), position the remote  
sensors and the main unit within the effective transmission range. Ideally they should be placed within the line of sight  
of the main unit. See placement tips in the user manual for each remote sensor.  
Transmission range may be affected by trees, metal structures and electronic appliances.  
The main unit must be placed indoors.  
The effective operating range may be influenced by the surrounding building materials and how the receiver (main unit)  
and transmitters (sensors) are positioned.  
Place the remote sensors so that they face the main unit (receiver), minimizing obstructions such as doors, walls, and  
furniture.  
Make sure that the remote sensors are easily accessible for cleaning and maintenance.  
Note: When the temperature falls below freezing, the outdoor sensor batteries may have reduced voltage and a reduced  
effective range. We recommend using lithium batteries at temperatures below 32°F (0°C).  
IMPORTANT: We recommend cleaning the remote sensors periodically, as dirt and debris affects sensor accuracy.  
Thermo-Hygrometer Sensor TS33C  
FEATURES  
LCD display of measured temperature and humidity  
Remote data transmission to the main unit via 433 MHz signal  
328 feet (100 meters) transmission range without interference  
Three (3) transmission channels selection  
Case can be wall mounted using built-in hanger  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
A. LED INDICATOR  
Flashes once when the remote sensor transmits a reading to the main unit.  
Flashes twice when battery power is low.  
B. BATTERY COMPARTMENT  
Holds two AA-size batteries  
C. RESET  
Resets all readings (requires small paper clip.)  
D. CHANNEL SWITCH  
Selects the desired sensor channel from 1 to 3  
E. WALL-MOUNT RECESSED OPENING  
Keeps the remote sensor on the wall  
Note: Install the batteries and select the channel before mounting the sensor  
Battery installation  
Remove the screws from the battery compartment with a small Phillips screwdriver.  
Set the channel 1 through 3. The switch is located in the battery compartment.  
IMPORTANT: When changing the channel, always press RESET or reinstall the batteries  
If you have more than one sensor, set one sensor to Channel 1 and the second sensor to Channel 2, etc. The sensors must  
operate on separate channels. Install 2 AA” size batteries matching the polarities shown in the battery compartment.  
IMPORTANT: When channel number is selected, it will be displayed on the sensors LCD display  
Replace the battery compartment door and secure the screws.  
Secure the thermo-hygrometer remote sensor in the desired location.  
Mounting  
The remote thermo-hygrometer sensor can be placed on the flat surface or mounted on the wall in vertical position  
Use the screws when mounting the thermo-hygrometer sensor on the wall  
Placement tips:  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
The remote thermo-hygrometer sensor should be placed in the area with a free air circulation and sheltered from the  
direct sunlight and an extreme weather conditions.  
Ideally, place the thermo-hygrometer sensor above the natural surfaces (such as a grassy lawn).  
Avoid placing the thermo-hygrometer sensor near sources of heat such as chimneys and heating elements.  
Avoid areas that collect or radiate heat from the sun, such as metal, brick/concrete structures, paving, or patio decks.  
The best location for temperature measurements is 4 feet (1.25meters) above the ground.  
Rain Gauge TS906  
FEATURES  
Precipitation measurement  
Remote rainfall data transmission to the main unit via 433 MHz signal  
100 feet (30 meters) opearting range without interference  
Built-in installation level  
A. Rain gauge bucket  
Contains electronic components  
B. Knob  
Secures the top on the rain gauge bucket  
C. Rain gauge feet  
Secures the rain gauge in place  
G
D
B
A
H
E
C
F
I
D. Funnel-shaped top with battery compartment  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contains battery compartment and rainfall counting electronics  
E. Battery compartment  
Holds two AA-size batteries  
F. Screws  
Secures battery compartment cover  
G. Built-in level with bubble  
Ensures level rain gauge mounting for proper operation  
H. Bucket see-saw mechanism  
Collects the rainfall in one of its containers and self-empties once full  
I. Protective screen  
Protects the rain gauge funnel from debris  
Battery installation  
Unlock the funnel-shaped top on the rain gauge by turning both knobs on the sides in an anti-clockwise direction.  
Remove the funnel-shaped top lifting it off the rain gauge bucket.  
Remove 7 small screws from the battery compartment cover using a small Phillips screwdriver  
Insert 2 AA” size alkaline batteries (not included), matching the polarities as shown in the battery compartment.  
Replace the battery compartment door and secure the screws.  
Insert the funnel-shaped top into the rain gauge bucket and secure it in place by turning the knobs clockwise.  
Mounting  
Make sure that the rain gauge bucket is level – check inside built-in level for bubble center.  
Place the protective screen over the top to protect the rain gauge from the debris.  
Where practical, mount the rain gauge in place with wood screws (not included).  
Make sure that the rain gauge is in open area where precipitation falls directly into the gauges bucket, ideally 2-3 feet  
above the ground.  
Placement tips  
The rain gauge should be placed in an open area away from the walls, fences, trees and other coverings which may  
reduce the amount of rain falling into the bucket. Additionally, trees and rooftops may be sources of pollen and debris.  
To avoid the rain shadow effects, place the rain gauge horizontally, on the distance corresponding to two to four times  
the height of any nearby obstruction.  
It is important to locate the unit where rain can flow away freely.  
Anemometer (wind sensor) TS805  
FEATURES  
Wind speed and wind direction measurement  
Remote wind speed and wind direction data transmission to the main unit via 433 MHz signal  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating range 100 feet (30 meters)  
Wall or pole mount  
A. WIND VANE  
Indicates wind direction  
B. WIND CUPS  
Measures wind speed  
C. ANEMOMETER BASE  
Holds battery compartment  
Allows mounting the anemometer vertically  
D. ANEMOMETER ARM  
Connects battery to the anemometer head assembly.  
A
E
D
G
C
B
F
H
E. WIND CUPS SHAFT  
Holds wind cups on the anemometer arm  
F. BATTERY COMPARTMENT  
Holds 2 AA-size batteries  
G. WALL MOUNT SCREW OPENINGS  
Allows securing the anemometer in place  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
H. BATTERY COVER  
Secures battery compartment on the anemometer base  
Assembly  
Slide the wind cups on to the anemometer rotating shaft. Do not use force.  
Insert the longer arm of the Allen Wrench (provided) into the wind cup set screw opening. Feel the head of the set  
screw inside the wind cups and tighten carefully the set screw securing the wind cups to the rotating shaft.  
Test to ensure cups are securely fastened to the shaft and cannot be removed  
Battery installation  
Remove four (4) screws from the battery compartment with a small Phillips screwdriver.  
Open the battery compartment and install 2 AA” size alkaline batteries (not included) matching the polarities shown.  
Do not close battery compartment yet as you need to make sure that the anemometer sends the signal to the main  
unit (0.0 mph will appear on the main units wind window if the signal was sent and received successfully)  
Aligning  
This procedure must be performed after main unit has been powered and all remote weather sensors were received  
successfully.  
Manually point the wind direction vane to the north (use a compass or map if necessary).  
Press the SET” button located inside battery compartment (on the shorter side) with a paper clip. SET” button selects  
a new direction for NORTH and, when pressed repeatedly, alternates between the factory default NORTH and user  
selected NORTH.  
Watch for the next anemometer data transmission in the main units wind window – the direction will be updated  
Replace the battery compartment door and secure the screws.  
Note: Repeat this procedure every time after changing the batteries.  
Mounting  
Mount the anemometer onto a vertical surface, using the fittings provided.  
Placement tips:  
The anemometer should be mounted in an open area with a free air flow; away from the nearby trees, buildings or  
other structures.  
For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main Unit  
The main unit measures pressure, indoor temperature, humidity, and receives atomic time data from the US Atomic Clock and  
outdoor measurements from remote sensors. It should be placed indoors.  
FEATURES  
Time  
Precise time and date set via RF signals from US Atomic clock  
12 or 24 hour time format  
Manual adjustment of time and date  
Calendar displaying date with month and day in 6 languages English, German, French, Italian, Spanish and Dutch  
Time Zones for over 100 pre-programmed world cities  
Moon Phase calendar and historical data for the past and future 39 days  
Dual crescendo alarms with programmable snooze  
Weather  
Weather forecast for the next 12 to 24 hour in seven large icons: Sunny, Partly Cloudy, Cloudy, Light Rain, Heavy  
Rain, Unstable Weather and Snowy  
Barometric pressure in imperial or metric units  
Altitude adjustment for pressure compensation  
24 hour barometric pressure history chart  
Multiple weather alerts including: Hi/Low temperature, Daily Rainfall, Hi wind gust and Hi wind speed alerts  
Indoor/Outdoor Temperature & Humidity in up to 4 remote locations (additional sensors required)  
Dew point and comfort level indicators  
Wind direction, speed and wind gust averages and memory  
Rainfall amount with minimum and maximum memory  
Operating range from 100 feet (30 meters) up to 328 feet (100 meters)  
Display  
Light sensor detects low light conditions and LCD lights up automatically when adapter is connected  
Power  
Open the battery compartment door on the back of the main unit.  
Insert four (4) AA size batteries according to the polarities shown and replace the battery compartment door.  
Connect 7.5V AC/DC adapter provided to the main display unit and plug into the wall power outlet.  
Note: The AC/DC adaptor connection is required for automatic backlight control. When the main unit operates  
solely on the battery power, the auto backlight control functions are disabled.  
When placing the main unit on the table or other horizontal surface, connect the table stand to the back of the unit.  
When mounting the main unit on the wall or vertical surface, detach the table stand and use the mounting hardware  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Placement tips  
Make sure that the main unit is locating within the operating range of all remote sensors.  
Ideally the remote sensors should be mounted within the line of sight of the main unit.  
Transmission range may be affected by trees, metal structures and electronic appliances.  
Test reception before permanently mounting all the remote sensors.  
Avoid placing the main unit in the following areas:  
Direct sunlight and surfaces emitting and radiating heat, such as heating ducts or air conditioners.  
Areas with interference from the wireless devices (such as cordless phones, radio headsets, baby listening devices)  
and electronic appliances.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Buttons and Controls  
H
I
G
F
E
D
C
B
A
K
J
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- Selects the next available window counter-clockwise  
- Increases parameters  
A. UP  
-If pressed and held, activates an atomic time signal search  
- Selects the next available window clockwise  
- Decreases parameters  
-If pressed and held, activates all remote sensors signal search  
- Alternates the parameters for the selected window  
- If depressed and held, enters into the programming mode or  
changes parameters units  
B. DOWN  
C. SET  
- Pressed again closes programming mode and confirms selected  
parameters  
- Manually selects the channel # for receiving temperature and  
humidity sensor data  
D. CHANNEL  
E. MEMORY  
- Enables the temperature and humidity channel auto-scan mode  
if pressed and held  
- Records: moon phase, temperature, humidity, rainfall and wind  
records. Then stores in memory  
- Moon phase: Determined by the day of month interval  
- Sets and stores pressure & altitude units in Memory  
- Allows displaying the sea-level pressure history  
F. HISTORY  
- Displays alarm times and programmed alerts for temperature,  
rainfall and wind.  
G ALARM/CHART  
- Press and hold, to enter the alarm/alert programming mode  
- Press and hold in pressure and forecast window, to view  
different bar charts  
H. SENSOR  
- Sets the light sensor to: automatic, on or off  
AUTO, ON, OFF  
I. SENSITIVITY  
HIGH/LOW  
- Adjusts the automatic light sensor sensitivity  
- Illuminates the display backlight for 5 seconds  
- Activates Snooze delay for alarms (programmable 1 to 15  
minutes)  
J LIGHT/SNOOZE  
- Connects main unit to the power outlet through the AC to 7.5V  
DC adapter provided  
K. AC/ DC  
ADAPTOR INPUT  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Initial Set up  
1. Power up each of the remotes as instructed in previous sections.( Remove clear protective plastic slips from the  
battery compartments)  
2. Then power up the main display.  
3. Once the main unit is powered, the display will briefly show all available LCD segments for a moment.  
4. IMPORTANT: Do not press any buttons during the set up process which typically takes about 5-10 minutes.  
The display functions will be automatically set including local altitude and pressure parameters. The display will show the  
pressure icon  
and “inHg” (inches of Mercury) flashing. You will know that the unit is finished self-adjustment when  
the display shows the default settings for the pressure and altitude (sea level) Indoor/outdoor temperature and humidity  
readings, remote sensors readings, etc.  
Many settings can be changed or customized to your preference, after the display has stabilized  
The pressure parameters during Initial Setup (See Pressure and Weather Forecast Window)  
The time, the date and the weekday language (Clock and Alarm Window)  
The location data (City) will determine the time zone  
IMPORTANT: If after the initial setup, the altitude or other parameters are not displayed, or dotted lines are displayed, for  
example (-.- -) you may have to restart the main unit to reset it..  
Note: It is a normal unit operation that history chart is constantly moving on the main unit display  
Operation and Window Selection  
The main unit has five different operating windows each displaying unique data. When a specific window is selected the  
corresponding icon will start flashing. Press the UP arrow button on the main unit to cycle through the windows clockwise or  
DOWN arrow button anti-clockwise.  
The basic operation of your weather station has been designed to work straight out of the box 10 minutes after power is  
provided to the main unit. You will have to select a city location following the steps identified under INITIAL SETUP before  
proceeding.  
Clock and Alarms Window  
Clock and Calendar Displays  
To alternate your view of the 5 Clock & Calendar displays, briefly press the SET button:  
1. Time with the Day of the week  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Time with the City abbreviation  
3. Time with the Seconds  
4. Month/ Day/ Year or Day/ Month/ Year.  
5. Current UTC Time (Coordinated Universal Time)  
Selecting Clock and Alarm Window  
Press main unit UP arrow button or DOWN arrow button until the clock icon  
next to the time/date display continues to  
flash.  
Initial Settings: City, Time, Date and Language  
With the Clock and Alarm icon flashing, press and hold SET button until the day of week language abbreviation “ENG”  
will flash.  
Press UP or DOWN arrow button to select the desired language for day of the week in English, German, French,  
Italian, Spanish or Dutch  
Press SET button to confirm selection.  
Select the desired City Code flashing (LAX is Los Angeles for example) for your area by pressing UP or DOWN. This  
will set the unit to the appropriate time zone for your location. Refer to table, back of this book, for a list of available  
cities.  
Press SET to confirm the city selection.  
Press UP or DOWN to select the correct year.  
Press SET to confirm year selection.  
Press UP or DOWN to select the correct month.  
Press SET to confirm selection.  
Press UP or DOWN to select the correct date.  
Press SET to confirm selection.  
Press UP or DOWN to select the correct order of month & year. (M…D)  
Press SET to confirm selection.  
Press UP or DOWN to select either 12 hour(AM/PM) or 24 hour time (24:00) format  
Press SET to confirm selection.  
Press UP or DOWN to select the correct hour.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Press SET to confirm selection.  
Press UP or DOWN to select the correct minute.  
Press SET to confirm selection and to complete the initial programming for your weather station.  
After programming is completed, the display will return to the default Clock and Alarm Window.  
Note: If you do not complete this sequence your entries will be lost.  
Note: Press and hold SET anytime during the setup to return to normal Clock and Alarm Window and all previous settings will  
be cancelled.  
Custom Weather Station Settings  
The basic operation of your weather station has been designed to work right out of the box 10 minutes after power is provided  
to the main unit. To use your station, you will have to complete the steps identified under INITIAL SETUP while this section of  
the manual will provide you with additional operational details and suggestions for custom settings and alarms including:  
The time alarms (Clock and Alarm Window)  
The temperature alerts (Temperature and Humidity Window)  
Daily rainfall alerts (Rain Window)  
Wind alerts (Wind Window)  
Pressure and Weather Forecast Window  
Your weather station is designed to display (local) barometric pressure, sea level pressure, weather forecast and moon phases.  
Historical statistics can also be viewed, including the sea-level pressure for the past 24 hours, moon phase for the past and  
following 39 days, and a selectable bar-chart for viewing pressure/ temperature & humidity history. Pressure is displayed inHg  
(English), hPa/mBar (scientific) or mmHg (metric). Altitude is displayed in meters or feet.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Select Pressure and Weather Forecast Window  
Press UP or DOWN arrow buttons on the main unit until the weather forecast icon  
begins to flash, upper display left  
corner.  
NOTE: Wait at least 5 - 10 minutes after initial set up to view a pressure or altitude information.  
Pressure and Altitude Information  
Press SET button once (do not hold it) to alternate between the Sea Level Pressure, Local Pressure and Local Altitude  
settings.  
The unit should be set to the default settings of: inHg (Inches of Mercury), and 33 feet. These parameters can be changed as  
desired at a later date, using the steps outlined in the section for Setting or Changing Pressure and Altitude settings.  
Changing Pressure and Altitude Parameters  
The weather station is designed to measure local pressure and calculate the other two parameters based on the Local  
Pressure. Sea Level Pressure and Altitude are interdependent. If you adjust altitude, it will calculate sea level pressure, if you  
adjust sea level pressure, it will automatically calculate altitude. You can only adjust one of the two – either sea level  
barometric pressure or altitude.  
If you wish to know pressure changes at your specific location (house), the LOCAL barometric pressure should be selected  
In this case, the local altitude/elevation must be programmed according to GPS readings, Internet, etc.  
If you wish to know pressure changes in your surrounding metro area, then SEA LEVEL barometric pressure option should  
be selected. In this case, the SEA LEVEL barometric pressure value can be adjusted according to the local metro area  
weather information. (Sources – local TV or radio station, etc)  
During initial power up (within the first 5 – 10 minutes) the weather station will not operate. These parameters can be modified  
after the display has stabilized  
Select the Pressure and Weather Forecast window by pressing UP or DOWN arrow button until the pressure and weather  
forecast icon  
starts flashing.  
NOTE: Locate your altitude with a portable GPS receiver or topographical map .Locate barometric pressure at:  
Changing or Setting Sea Level Pressure  
Press SET button until the local pressure with the word “SEA LEVEL” is displayed.  
Press and hold MEMORY button until the pressure unit is flashing, inHg, mmHg or hPa/mBar  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set the pressure units by pressing the UP or DOWN arrow buttons  
Press MEMORY button to confirm your selection  
Press and hold SET button until the local pressure digits will flash.  
Set the sea level pressure by pressing the UP or DOWN buttons to adjust the pressure value. Press and hold UP or  
DOWN arrow buttons for faster digits advancement  
Press SET to confirm your selection.  
Changing or Setting Altitude  
Press SET button until the local altitude value will be displayed  
Press and hold MEMORY button until the altitude unit is flashing, Feet or Meters.  
Press UP or DOWN arrow buttons to set altitude in feet or meters  
Press MEMORY button once to confirm your selection  
Press and hold SET until the pressure digits are flashing.  
Set the altitude value by pressing the UP or DOWN arrow buttons. Press and hold UP or DOWN arrow button for  
faster digits advancement  
Press SET button to confirm your selection.  
Viewing the Sea Level Pressure History  
From any mode, press the HISTORY button. Unit will select the Pressure/ Weather display.  
When the SEA LEVEL is displayed, press HISTORY button repeatedly viewing the sea level pressure history for the  
past 24 hours in hour intervals.  
If no buttons are pressed for 5 seconds, the unit will automatically exit history mode and return to the Pressure and  
Weather Forecast mode  
.
Viewing the Pressure, Temperature and Humidity Bar Charts  
The pressure bar graph shows barometric pressure variations over the past 24 hours. This is very useful for understanding the  
Barometric trends that are used in weather forecasting. Each bar icon represents 0.06 inHg.  
Alternatively, the bar chart can be used to display 24 hour trend data for Sea Level Pressure, CH 1 Remote temperature or  
Ch1 Remote humidity.  
Select the Pressure and Weather Forecast window, press and hold ALARM/CHART button to toggle the bar chart title at the  
right bottom corner of the chart. Alternate between PRESSURE, “CH1temperature (thermometer icon) and CH1” relative  
humidity (dew drop icon)  
Viewing the Moon Phase History  
The unit indicates the current moon phase and using the MEMORY button will permit viewing of the past or future days.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Previous moon phases are selected with the minus sign selected: -1 day, -2 days, etc or future moon phase are selected  
based on the days ahead: +1 day, + 2 days, etc up to 39 days.  
After selecting the Pressure and Weather Forecast display, press MEMORY button, so “+ 0 days” is flashing.  
Press UP or DOWN arrow buttons selecting from todays date a future (+) or past (-) days and the corresponding  
moon phase will be displayed. Press and hold either button for a quick advance.  
To exit, press MEMORY button.  
The Moon Phase Diagram  
Weather Forecast Displays  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The weather forecast accuracy is approximately 70%. Display shows 12 to 24 hour forecast, not current conditions. The  
SUNNY icon indicates clear weather, even when displayed during the night-time.  
Temperature and Humidity Window  
The weather station supports Indoor Temperature & Humidity and up to five remote temperature and humidity sensors (1  
remote sensor is included).  
Temperature can be displayed in either Celsius (ºC) or Fahrenheit (ºF). The main unit calculates indoor comfort level - Wet,  
Comfort or Dry. Dew Point based on temperature & humidity readings. The main unit can be programmed to alarm if the  
temperature exceeds or falls below the pre-set upper and lower limits on all remote channels. The limits are the same for all  
remote channels. Thermo-Hygrometer remote battery status is monitored on the main unit.  
Temperature and Humidity Display:  
Selecting Temperature and Humidity Window  
Press main unit UP or DOWN arrow buttons until the IN icon  
on the upper right will flash.  
Viewing Temperature and Humidity for each Channel  
At any time simply press the CHANNEL button to recall a different remote thermo hygrometer channel.  
Channel Auto-Scan Display:  
To enable automatic scan of all available channels, press and hold CHANNEL button, until the  
icon is displayed.  
Channels will be alternately displayed with a 5-second delay.  
Temperature and Dew Point Displays  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
With Temperature and Humidity icon flashing, press the SET button to alternate between temperature and relative humidity” or  
dew point and relative humidity.”  
Temperature in Celsius or Fahrenheit  
With Temperature and Humidity icon flashing, press and hold the SET button to alternate between temperature in Celsius (ºC)  
or Fahrenheit (ºF).  
Temperature Alarm  
With Temperature and Humidity icon flashing, press the ALARM/CHART button once every time to recall a current  
temperature for the corresponding channel, the upper temperature alarm limit with  
icon, or lower temperature alarm limit  
with  
icon (if disabled, displays OFF). You can program temperature alarm limits for all five temperature and humidity  
channels  
Programming Upper and Lower limits for Temperature Alarm  
In the Temperature and Humidity Mode, press ALARM/CHART button once selecting the desired alarm limit – Upper  
or Lower  
Press and hold ALARM/CHART button until the remote temperature and  
(Upper Alarm) or  
(Lower Alarm) icon  
starts flashing.  
Adjust the temperature digits for the corresponding Temperature Alarm limit using the UP Sor DOWN Tbuttons.  
Press and hold either button for fast digits advance.  
Press the ALARM/CHART button to confirm selection and return to the Temperature Alarm selection screen.  
Disabling Temperature Alarm levels  
With the Temperature & Humidity icon flashing, press the UP or DOWN arrow button to disable the alarm(s) – OFF will be  
displayed if alarm is disabled  
Note: The temperature alarms have a 0.5 ºC deviation to prevent false alarms due to small temperature fluctuations.  
Temperature has to fall below (or above) the programmed level(s) to activate the alert.  
Viewing the Max/Min Channel Temperature and Humidity  
With the Temperature & Humidity icon flashing, press the MEMORY button to recall a current temperature and humidity,  
minimum temperature and humidity or maximum temperature and humidity at the remote location. To clear the temperature  
and humiditys memories, press and hold the MEMORY button.  
Rain Window  
The main unit records the total amount of the rainfall for the last hour, 24 hours, past day, past week and the past month. The  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
rainfall can be displayed in mm or inches. There is a daily rainfall alert that can be programmed in the unit if the daily rainfall  
exceeds a pre-programmed limit.  
Selecting Rain Window  
Press the UP or DOWN arrow buttons on the main unit until the RAIN icon  
on the display starts flashing.  
Display:  
Viewing Rain Statistics  
With the rain icon flashing Press either SET or MEMORY button to recall a rain statistics for the past hour, past 24 hours,  
yesterday, past week or past month.  
Note: Last Hour rainfall value is displayed as a rate of rain in either inch/hr” or mm/hr”.  
Rainfall Memory Reset  
With the rain icon flashing, press and hold the MEMORY button to reset all rainfall statistics.  
Setting Rain Display; inches or mm  
With the rain icon flashing, press and hold the SET button to toggle rainfall data units between mm and inches.  
Enabling or Disabling Daily Rainfall Alert  
With the rain icon flashing, press the ALARM/CHART button to display either the current rainfall statistics or the daily  
rainfall alert with ALARM HI” displayed.  
If the alert is disabled, the OFFwill be displayed; otherwise the rainfall alert value will be shown.  
When the rainfall alert is displayed, press the UP or DOWN arrow button to enable or disable it.  
Setting up Daily Rainfall Alert  
With the rain icon flashing, press ALARM/CHART button to display the rainfall alert.  
Press and hold ALARM/CHART button until the rainfall alert ALARM HIwill flash.  
Set the desired value for the Rainfall Alert by using UP or DOWN arrow button. Press and hold either button for fast  
digits advance.  
Press ALARM/CHART button to confirm selection and the unit will return to the rainfall alert display.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disabling the Daily Rainfall Alert  
In the Daily Rainfall Alert Mode press the ALARM/CHART button to disable the alert.  
Wind Window  
Wind direction is shown by compass points (i.e. NW) or in bearings starting from north (i.e. 22.5º). The unit displays  
anemometer temperature or wind chill, average wind speed (over the past 10 minutes), gust, and wind other information. It  
records the maximum wind speed and gusts collected during the day. Wind speed and gust alerts can be programmed based  
on pre-configured limits. Wind speed is displayed in km/h, mph, m/s or knots.  
Selecting Wind Window  
Press main unit UP or DOWN until the WIND icon  
on the display starts flashing.  
Note: The wind speed alert is set at 5 mph default and the wind gust alert is set to 7 mph default to prevent false alerts from  
small fluctuations.  
Configuring Wind Display  
With the wind icon flashing, press the SET button to alternate between wind chill with direction in bearings, “wind chill with  
direction in compass points, “anemometer temperature & wind direction in compass points” or anemometer temperature and  
wind direction in bearings.”  
Setting Wind Speed in km/h, mph, m/s or knots  
With the wind icon flashing, press and hold the SET button to set the wind speed units in km/h, mph, m/s or knots.  
Viewing Wind Statistics  
With the wind icon flashing, press the MEMORY button to recall a current wind speed, a daily maximum wind speed with  
DAILY MAX” displayed, a gust speed with a “GUSTdisplayed and a daily maximum gust speed with a “GUST DAILY MAX”  
displayed.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Resetting the Wind Statistics Memory  
With the wind icon flashing, press and hold MEMORY button to reset all wind statistics.  
Enabling or Disabling the Wind Alerts  
With the wind icon flashing, press the ALARM/CHART button to recall a current wind speed, a wind speed alert with the  
ALARM HI” displayed or gust alert with the “GUST ALARM HI” displayed.  
If the alert is disabled, “OFF” will be displayed; otherwise the alert value is shown.  
When a wind alert is displayed, press UP or DOWN arrow button to activate or deactivate it.  
Wind Alert programming  
With the wind icon flashing, press ALARM/CHART button to select the desired alarm.  
Press and hold ALARM/CHART button until alert and corresponding icon will flash.  
Set the alert using UP or DOWN arrow button. Press and hold either button for fast digits advance.  
Press ALARM/CHART button to confirm your selection and return to the wind alert selection screen.  
Disabling the Wind Alert  
To disable wind alert when it is displayed after pressing ALARM/CHART button press UP or DOWN arrow button – OFF will  
be displayed instead of previously set alarm time.  
LED Backlight Options  
The main unit backlight can be turned on, off or automatic depending on light conditions. The sensitivity of the backlight sensor  
can be adjusted to high or low using the switch, located on the back panel.  
Note: For continuous backlight control the AC/DC adaptor must be plugged in.  
Time Alarm Settings  
There are two time alarms available on the main unit: Weekday alarm (W), and Single alarm (S)  
If Weekday alarm is activated, it will sound at the set time and the alarm icon will flash Monday through Friday.  
If Single day alarm is activated, it will sound at the set time and the alarm icon will flash only for this specific day and  
will not activate on subsequent days.  
Note: The snooze duration for listed alarms can also be programmed up to 15 minutes.  
Enable/Disable Time Alarms  
Press the ALARM/CHART button to display the Weekday Alarm or Single Day Alarm time. If these alarms are not set,  
the abbreviation OFF will be displayed.  
To enable or disable any of these alarms, press UP or DOWN arrow button  
Press ALARM/CHART button to confirm your setting  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: Press SET button anytime during alarm programming mode to return to the default clock display.  
Programming Time Alarms  
With the Clock and Alarm icon flashing, press the ALARM/CHART button to select the desired alarm.  
Press and hold ALARM/CHART button until the hour digit will flash  
Set the alarm hour using UP or DOWN arrow button. Press and hold either button for quick digit advance.  
Press ALARM/CHART to confirm selection.  
Set the alarm minutes using UP or DOWN arrow button. Press and hold either button for quick digit advance.  
Press ALARM/CHART button to confirm selection.  
Set a Snooze interval (both alarms share same snooze time duration) using UP or DOWN arrow button. Press and  
hold either button for quick digit advance.  
Press ALARM/CHART button to confirm your selection.  
After programming is completed, the display will return to the alarm selection screen.  
Disable/Enable Snooze function  
To enable a snooze function press LIGHT/SNOOZE button.  
Note: Alarm will automatically snooze” if no buttons are pressed after the alarm sounds for 2 minutes. This will occur three  
times only.  
Disable alarm(s):  
Press ALARM/CHART button to disable the alarm (s).  
Note: For weekday alarm, pressing ALARM/CHART button will only disable the alarm for the current day. The alarm will  
activate again on the next day, Monday through Friday.  
Atomic Time Reception  
The purpose of the atomic clock is to provide consistently accurate time and date automatically. The radio controlled clock  
searches for, and periodically synchronizes to, the NIST (National Institute of Standards and Technology) Atomic clock signal  
transmitted from Colorado, throughout the entire continental United States.  
During night-time hours, atmospheric conditions improve radio signal reception. A single daily reception is sufficient  
enough to keep the clock accuracy within milliseconds.  
Unit should be positioned 8 feet (2 meters) from interference sources such as a TV, computer, microwave, etc.  
The signal reception is weakened within concrete walls found in basements or office buildings. Place the unit near the  
window for best reception.  
It takes between 24 and 72 hours for the clock to receive an atomic time signal reception  
Once the atomic time signal is received, the date and time will be set automatically, and the  
icon will appear. Your atomic  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
clock is programmed to search for the atomic time signal daily each hour between 1:00 am and 4:30 am. Once the time signal  
has been successfully received, the time and date will be updated automatically.  
To manually enable or disable the atomic time receiver:  
Press and hold UP arrow button - if atomic time reception is activated, a triangular tower icon will start flashing next to  
the clock icon. If reception is disabled, the triangular tower icon will disappear.  
Remote Sensor Status  
The wave icon above the current channel display shows the connection status of the corresponding remote sensor:  
Activate Search for Remote Sensors  
Normally the main display will automatically find and display measurement results from the remote sensors. However,  
occasionally other radio transmission sources (TV, Cordless or Cell Phones etc) can interrupt the sensor signal. If this happens  
simply press and hold the DOWN arrow button for 4 – 6 seconds to activate a new search.  
Memory Reset Procedure  
These steps will completely reset all of the parameters stored in memory.  
On the main unit press and hold SNOOZE and UP buttons for 4 seconds until the backlight will flash  
Press SET button clearing the memory -the main unit will start beeping with 1 second delay.  
Wait until the beeping will cease  
Disconnect main unit from the AC/DC adapter and remove the batteries from the back of the main display unit and wait  
10 seconds  
Reinstall the batteries and reconnect the main unit to the wall power outlet through the AC/DC adapter  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
Changing Batteries  
The battery status of each weather sensor is checked every hour. If the low battery indicator lights up, replace the batteries in  
the corresponding unit.  
Changing Batteries in the Main Unit  
First connect the AC/DC adaptor provided to the main unit to avoid losing any data.  
Remove the battery compartment door at the back and replace all batteries. Do not mix old and new batteries.  
Replace the battery compartment door.  
Changing Remote Sensor Batteries  
Replace the batteries following the setup instructions for the corresponding sensor.  
When the batteries are properly installed, the remote sensor will resume sending signals to the main unit.  
To enforce an immediate remote signals search, press and hold DOWN arrow button for 4-5 seconds on the main  
unit.  
Cleaning  
The main unit and remote sensor casings can be cleaned with a damp cloth. Small parts can be cleaned with a cotton tip or  
pipe-cleaner. Never use abrasive cleaning agents and solvents. Do not immerse units with electronic parts under water.  
Anemometer  
Assure that wind vane and wind cups spin freely and are free from dirt, debris and spider webs.  
Rain Gauge  
Checking and cleaning the rain sensor in a timely manner will maintain an accuracy of the precipitation measurements.  
Remove the protective screen and lid.  
Clean with soapy water and a damp cloth, removing dirt, leaves or debris  
Clean small holes and parts with Q-tips or pipe-cleaner.  
Clean the swinging mechanism with a damp cloth.  
Troubleshooting  
Q: “The display shows dashes “---” for weather parameter(s)”  
A: The display will show - - -” when the wireless connection with the remote sensor is lost for the following periods:  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thermo-Hygrometer  
Anemometer (Wind Sensor): 15 minutes  
Rain Gauge (Rain Sensor) 30 minutes  
15 minutes  
Check or replace the batteries for the corresponding sensor. Then press and hold DOWN arrow button on the main unit to  
search for all remote signals. If this does not work, check the wireless transmission path from the corresponding sensor to the  
main unit and change locations to improve reception. Wireless signals pass through solid objects and walls, however,  
whenever is possible the sensor should be within line-of-sight with the main unit.  
The following may cause reception problems:  
The remote weather sensor and a main unit are too far from each other.  
The signal shielding materials, such as metal surfaces, concrete walls or dense vegetation, are in the path of  
transmission.  
Interference from wireless devices such as: cordless phones, radio headsets and baby listening devices or electronic  
appliances.  
Q: “My weather station readings are different from TV, radio or official weather reports.”  
A: The weather data may vary considerably due to different environmental conditions and placement of the remote sensors.  
If readings are in question, check the sensor placement tips included in this manual.  
Q: “The weather forecast is inaccurate.”  
A: Weather forecast predicts the weather for the next 12 to 24 hours, and does not reflect current weather conditions.  
PRECAUTIONS  
This product is engineered to give you years of satisfactory service if handled carefully. Here are a few precautions:  
Do not immerse the units in water.  
Do not clean the units with abrasive or corrosive materials that might scratch plastic parts or corrode electronic  
circuits.  
Do not subject the product to excessive force, shock, dust, temperature, or humidity, which may result in malfunctions,  
shorter lifespan, damaged batteries, and damaged parts.  
Do not tamper with the products internal components. Doing so will invalidate the warranty and may cause damage.  
The product contains no user-serviceable parts.  
Use only fresh batteries. Do not mix new and old batteries.  
Read the user's manual thoroughly before operating the product.  
Appendix - City Codes  
The Table below will assist in determining the appropriate time zones.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Radio Frequency: 433 MHz  
RF Reception range: 100-328 feet (30 -100 m)  
Barometric Pressure  
Measuring Range: 14.75 inHg to 32.44 inHg (500 Hpa to 1100Hpa); (374.5 mmHg to 823.8 mmHg)  
Resolution:  
Accuracy:  
0.003 inHg (0.1 Hpa, 0.08 mmHg)  
0.015 inHg (0.5 Hpa; 0.38 mmHg)  
Sampling interval: 20 minutes  
Sea level Altitude Compensation Range: -657 ft to 16404 ft (-200m to +5000 m)  
Temperature (Indoor)  
Operating Range: 14.2°F to 140°F (-9.9°C to 60°C)  
Resolution: 0.2°F (0.1°C)  
Accuracy: 2°F (1°C)  
Sampling Interval: 10 seconds  
Temperature (Remote)  
Range: -40°F to 176°F (-40°C to 80°C)  
Resolution: 0.2°F (0.1°C)  
Accuracy: 2°F (1°C)  
Transmitting Interval: around 47 seconds  
Operating range: 328 feet (100 m)  
Humidity (Indoor)  
Operating Range: 30% to 80%  
Resolution: 1%  
Accuracy: 5%  
Sampling Interval: 10 seconds  
Humidity (Remote)  
Operating Range: 30% to 80%  
Resolution: 1%  
Accuracy: 5%  
Sampling Interval: 10 seconds  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmitting Interval: around 47 seconds  
Operating range: 328 feet (100 m)  
Wind Direction  
Range: 0° to 360°  
Resolution: 22.5°  
Accuracy: 11.25°  
Starting Threshold: 3mph (4.8 Km/h)  
Transmitting interval: 33 seconds  
Operating Range: 100 feet (30 m)  
Wind Speed  
Range: 0 to 100 mph (160 Km/h, 86.897 Knots)  
Resolution: 0.1mph (0.16 Km/h)  
Accuracy: (2mph + 5%)  
Starting Threshold: 3mph (4.8 Km/h)  
Wind/Gust Speed Display Update Interval: 33 seconds  
Wind/Gust Sampling Interval: 11 seconds  
Operating Range: 100 feet (30 m)  
Rainfall  
1h/24h/yesterday range: 0 to 78.73 inch (0 to 1999.9 mm)  
Last week/ last month range: 0 to 787.3 inch (0 to 19999 mm)  
Resolution: 0.03 inch (0.6578 mm)  
Accuracy: +/- 5% +/- 0.03 inch (+/-5%mm +/-0.6875)  
Transmitting Interval: 183 seconds  
Operating Range: 100 feet (30 m)  
Power (12 AA Batteries) - included  
Main unit: 4 x UM-3 or AA 1.5V battery; 7.5V AC/DC power adaptor (200mA; center pin positive)  
Remote Thermo Hygrometer: 2 x UM-3 or AA 1.5V battery  
Remote Anemometer: 2 x UM-3 or AA 1.5V battery  
Remote Rain Gauge: 2 x UM-3 or AA 1.5V battery  
Battery life (alkaline)  
Main unit: 2 month (without AC adapter)  
Thermo-Hygrometer: over 12 months  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Anemometer: 2 years  
Rain Gauge: 2 years  
Weight (without batteries)  
Main unit: 8.15oz (231g)  
Remote Thermo-Hygrometer: 2.29oz (65g)  
Remote Anemometer: 11.12oz (315g)  
Remote Rain gauge: 10.24oz (290g)  
Dimensions  
Main unit: 7.31 (L) x 5.39 (H) x 1.26 (D) inches / 185.8 (L) x 136.9 (H) x 32 (D) mm  
Remote Thermo - Hygrometer: 2.37 (L) x 4 (H) x 1 (D) inches / 60 (L) x 101 (H) x 25 (D) mm  
Remote Anemometer: 19.16 (L) x 19.16 (H) x 15.35 (D) inches / 486.6 (L) x 486.6 (H) x 390 (D) mm  
Remote Rain gauge: 6.49 (L) x 6.89 (H) x 4.72 (D) inches / 165 (L) x 175 (H) x 119 (D) mm  
FCC STATEMENT  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may  
not cause harmful interference, and (2) This device must accept any interference received, including interference that may  
cause undesired operation.  
Warning: Changes or modification to this unit not expressly approved by the party responsible for compliance could void the  
users authority to operate the equipment.  
NOTE: This equipment had been tested and found to comply with the limits for a Class B Digital device, pursuant to Part 15 of  
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential  
installation. This equipment, installed and used in accordance with the instructions, may cause harmful interference to radio  
communications.  
There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to improve or correct turning the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna  
Increase the separation between the equipment and receiver.  
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio / TV technician for help.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DECLARATION OF CONFORMITY  
Name: Meade Instruments Corp.  
Address: 27 Hubble, Irvine, CA 92618  
Telephone No.: 1-949-451-1450  
declare that the product  
Product No.: TE821W  
Product Name: Semi-Professional Weather Station  
Manufacturer: Hideki Electronics Ltd.  
Address: Unit 2304-06, 23/F Riley House, 88 Lei Muk Road, Kwai Chung, New Territories, Hong Kong  
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
This device may not cause harmful interference.  
This device must accept any interference received, including interference that may cause undesired operation.  
The information above is not to be used as a contact for support or sales. Please call our customer service (refer to  
the Standard Warranty Information) for all injuries instead.  
STANDARD WARRANTY INFORMATION  
This product is warranted from manufacturing defects for one year from date of retail purchase. It does not cover damages or  
wear resulting from accident, misuse, abuse, commercial use, or unauthorized adjustment and repair.  
Should you require assistance with this product and its operation, please contact our Customer Service 1(800) 626 3233.  
Please direct all returns to the place of the original purchase. Should this not be possible, contact Meade Customer Service  
Hotline for assistance and to obtain a Return Goods Authorization (RGA). Returns without a return authorization will be refused.  
Please retain your original receipt as you may be asked to provide a copy for proof of purchase.  
Meade Instruments Corp. reserves the right to repair or replace the product at our option.  
Copyright (2010) Meade Instruments Corp. All Rights Reserved. The Honeywell Trademark is used under license from  
Honeywell International Inc.  
Honeywell International Inc. makes no representations or warranties with respect to this product.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Saw G9743 User Manual
Haier TV Receiver 21F9D 21T9D 21F9K 21TA1S 21TA1D 21FA1 21TA1 21T9DD 21T9DS 21T9DB 21F7A HT 3728 HT 3768 37T6D T 15F6B 21TA1B 21TA1BG User Manual
Harbor Freight Tools Tool Storage 67422 User Manual
Hearth and Home Technologies Indoor Fireplace SOULSTICE User Manual
Honeywell Home Security System 128 User Manual
HP Hewlett Packard Stereo Amplifier RC3000 User Manual
Humminbird Fish Finder 747c User Manual
Husqvarna Saw K970 User Manual
Hypertec Carrying Case TAVS0702HY User Manual
IBM Fan 92P1477 User Manual