Download from Www.Somanuals.com. All Manuals Search And Download.  
REVISION HISTORY  
DATE  
MODIFICATION  
SOFTWARE VERSION  
8 March 1999  
13 April 1999  
1 June 1999  
13 March 2000  
15 November 2002  
10 January 2003  
3 January 2005  
1 December 2005  
Preliminary document  
Initial Release  
Update  
Software Update  
Chapter 2 Update  
Appendix E Update  
Manual Format Update  
Software Update  
1.00  
1.04  
1.07  
1.16  
1.37  
1.38  
1.46  
1.55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
Research Concepts, Inc.(RCI) warrants to the original purchaser, this product shall be free from defects  
in material and workmanship for one year, unless expressed otherwise, from the date of the original  
purchase.  
During the warranty period, RCI will provide, free of charge, both parts and labor necessary to correct  
such defects.  
To obtain such a warranty service, the original purchaser must:  
(1)  
Notify RCI as soon as possible after discovery of a possible defect, of:  
(a) the model and serial number  
(b) identify of the seller and date of purchase  
(c) detailed description of the problem, including details on the electrical connection to associated  
equipment and list of such equipment, and circumstances when problem arose.  
(2)  
Deliver the product to RCI, or ship the same in its original container or equivalent, fully insured  
and shipping charges prepaid.  
Correct maintenance, repair, and use are important to obtain proper performance from this product.  
Therefore, read the instruction manual carefully and completely. This warranty does not apply to any  
defect that RCI determines is due to:  
- Improper maintenance or repair, including the installation of parts or accessories that do not  
conform to the quality and specifications of the original parts.  
- Misuse, abuse, neglect, or improper installation including disregard for installation of backup or  
safety override equipment.  
- Accidental or intentional damage.  
- Lightning or acts of God.  
There are no implied warranties.  
The foregoing constitutes RCI's entire obligation with respect to this product, and the original purchaser  
and any user or owner shall have no other remedy and no claim for incidental or consequential damages.  
Some states do not allow limitations or exclusions of incidental or consequential damages, so the above  
limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may  
also have other rights which may vary from state to state.  
RCI retains the right to make changes to these specifications any time, without notice.  
Copyright – Research Concepts Inc., 2005  
REPAIR RETURN INFORMATION  
To help guarantee a fast and efficient repair, the user should request and receive a Return Merchandise  
Authorization number (RMA#) from Research Concepts Inc. prior to shipping the unit.  
In addition, international returns are required to complete the correct documents necessary for achieving  
U.S. Customs clearance. In order to avoid duties and taxes, export documents must be accurately  
completed to meet Export Administration Regulations. Contact RCI for guidance with respect to the  
correct completion of shipping documents.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
1.0 INTRODUCTION.................................................................................................................................................1  
1.1 MANUAL ORGANIZATION.....................................................................................................................................1  
1.2 RC3000 FEATURES ..............................................................................................................................................3  
1.3 THEORY OF OPERATION .......................................................................................................................................5  
1.3.1 Controller Description .................................................................................................................................5  
1.3.2 System Interface Requirements ....................................................................................................................6  
1.3.3 Operational Overview..................................................................................................................................7  
1.3.4 Antenna Pointing Solution ...........................................................................................................................9  
1.3.5 Timekeeping ...............................................................................................................................................11  
1.3.6 Drive System...............................................................................................................................................11  
1.3.7 Polarization Control ..................................................................................................................................13  
1.3.8 Magnetic Variation ....................................................................................................................................14  
1.3.9 System Performance...................................................................................................................................15  
1.4 SPECIFICATIONS .................................................................................................................................................16  
2.0 INSTALLATION ................................................................................................................................................17  
2.1 EQUIPMENT MOUNTING .....................................................................................................................................18  
2.1.1 RC3000 Antenna Controller.......................................................................................................................18  
2.1.2 GPS Receiver..............................................................................................................................................19  
2.1.3 Fluxgate Compass......................................................................................................................................20  
2.1.4 Electronic Clinometer ................................................................................................................................22  
2.2 ELECTRICAL CONNECTIONS ...............................................................................................................................24  
2.2.1 Power Entry................................................................................................................................................25  
2.2.2 Motor Drive................................................................................................................................................26  
2.2.3 Drive Sense.................................................................................................................................................27  
2.2.4 Limit Switches ............................................................................................................................................28  
2.2.5 Signal Strength...........................................................................................................................................29  
2.2.6 Navigation Sensors.....................................................................................................................................30  
2.2.7 Accessories.................................................................................................................................................31  
2.2.8 RF Autopeak...............................................................................................................................................32  
2.2.9 Hand Held Remote .....................................................................................................................................33  
2.2.10 Pulse Sensors ...........................................................................................................................................35  
2.2.11 Remote Control ........................................................................................................................................38  
2.2.12 Waveguide Switch ....................................................................................................................................39  
2.2.13 Resolver Inputs.........................................................................................................................................40  
2.3 INITIAL CONFIGURATION....................................................................................................................................41  
2.3.1 Software Initialization................................................................................................................................41  
2.3.2 Elevation Calibration.................................................................................................................................43  
2.3.3 Azimuth Calibration ...................................................................................................................................47  
2.3.4 Polarization Calibration ............................................................................................................................50  
2.3.5 Fast/Slow Motor Speed ..............................................................................................................................53  
2.3.6 Pulse Sensor Checkout...............................................................................................................................53  
2.3.7 Drive System Checkout...............................................................................................................................53  
2.3.8 Navigation Sensor Communication............................................................................................................53  
2.4 FINAL CALIBRATION ..........................................................................................................................................54  
2.4.1 Compass Calibration..................................................................................................................................54  
2.4.2 Azimuth and Elevation Alignment..............................................................................................................55  
2.4.3 Signal Strength Adjustment ........................................................................................................................57  
2.4.3.1 L-Band Power Detector .........................................................................................................................................57  
2.4.3.2 Signal Strength Channel ........................................................................................................................................57  
2.4.3.3 Signal Strength Channel Calibration......................................................................................................................58  
2.4.3.4 Amplifier Gain vs. Frequency Characterization ....................................................................................................59  
2.4.4 Pulse Scale Factors....................................................................................................................................60  
2.4.5 Operational Presets....................................................................................................................................62  
2.4.6 Miscellaneous Adjustments ........................................................................................................................62  
2.4.7 Mechanizing Automatic Locates ................................................................................................................62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.0 DETAILED OPERATION ................................................................................................................................ 63  
3.1 OPERATION OVERVIEW...................................................................................................................................... 63  
3.1.1 Modes......................................................................................................................................................... 63  
3.1.2 Keypad Usage............................................................................................................................................ 64  
3.1.3 Data Entry ................................................................................................................................................. 66  
3.1.4 Display Layout........................................................................................................................................... 67  
3.2 OPERATING GROUP............................................................................................................................................ 68  
3.2.1 Manual Mode............................................................................................................................................. 69  
3.2.1.1 Heading Fix........................................................................................................................................................... 71  
3.2.1.2 Waveguide Switch................................................................................................................................................. 72  
3.2.2 Menu Mode ................................................................................................................................................ 73  
3.2.2.1 Deploy................................................................................................................................................................... 74  
3.2.2.2 Stow....................................................................................................................................................................... 75  
3.2.2.3 Locate.................................................................................................................................................................... 76  
3.2.2.3.1 Satellite Selection........................................................................................................................................... 77  
3.2.2.3.2 LOCATE Automatic Movement.................................................................................................................... 79  
3.2.2.3.3 Azimuth Scanning Autopeak ......................................................................................................................... 80  
3.2.2.3.4 Spiral Search Autopeak.................................................................................................................................. 82  
3.2.2.3.5 Terminal Peak Up .......................................................................................................................................... 83  
3.2.2.3.6 Polarization Tilt Compensation...................................................................................................................... 83  
3.2.2.4 Store ...................................................................................................................................................................... 84  
3.2.2.5 Recall..................................................................................................................................................................... 85  
3.2.2.6 Delete .................................................................................................................................................................... 85  
3.2.2.7 Position.................................................................................................................................................................. 86  
3.2.2.7.1 LAT/LON ...................................................................................................................................................... 86  
3.2.2.7.2 HEADING ..................................................................................................................................................... 87  
3.2.2.7.3 INIT ............................................................................................................................................................... 87  
3.2.2.8 Settings.................................................................................................................................................................. 89  
3.2.2.9 Track ..................................................................................................................................................................... 90  
3.2.2.10 Remote ................................................................................................................................................................ 90  
3.2.2.11 VSAT Mode ........................................................................................................................................................ 91  
3.3 PROGRAMMING GROUP...................................................................................................................................... 94  
3.3.1 Configuration Mode................................................................................................................................... 94  
3.3.1.1 NORMAL ACCESS ITEMS................................................................................................................................. 96  
3.3.1.1.1 Expert Access Permission.............................................................................................................................. 96  
3.3.1.1.2 Preset Locations............................................................................................................................................. 97  
3.3.1.1.3 Preset Satellites.............................................................................................................................................. 98  
3.3.1.2 INSTALLATION ACCESS ITEMS ..................................................................................................................... 99  
3.3.1.2.1 System Definition .......................................................................................................................................... 99  
3.3.1.2.2 Elevation Calibration ................................................................................................................................... 100  
3.3.1.2.3 Azimuth Calibration..................................................................................................................................... 102  
3.3.1.2.4 Polarization Calibration ............................................................................................................................... 104  
3.3.1.2.5 Signal Strength Factors ................................................................................................................................ 105  
3.3.1.2.6 Autopeak...................................................................................................................................................... 106  
3.3.1.3 Super-User Access Items..................................................................................................................................... 108  
3.3.1.3.1 Reset Defaults .............................................................................................................................................. 108  
3.3.1.3.2 Azimuth Pot Drive ....................................................................................................................................... 109  
3.3.1.3.3 Azimuth Pulse Drive................................................................................................................................... 110  
3.3.1.3.4 Azimuth Drive Monitoring .......................................................................................................................... 111  
3.3.1.3.5 Elevation Pot Drive...................................................................................................................................... 113  
3.3.1.3.6 Elevation Pulse Drive.................................................................................................................................. 114  
3.3.1.3.7 Elevation Drive Monitoring ........................................................................................................................ 114  
3.3.1.3.8 Polarization Drive ........................................................................................................................................ 115  
3.3.1.3.9 Pol Drive Monitoring................................................................................................................................... 115  
3.3.1.3.10 Stow & Deploy Positions........................................................................................................................... 116  
3.3.1.3.11 SHAKE ...................................................................................................................................................... 117  
3.3.2 Maintenance Items................................................................................................................................... 118  
3.3.2.1 Analog to Digital Voltage ................................................................................................................................... 119  
3.3.2.2 Drive Error Resets............................................................................................................................................... 120  
3.3.2.3 Time Maintenance............................................................................................................................................... 120  
3.3.2.4 Signal Strength Offset Calculator........................................................................................................................ 122  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.2.5 Limits Maintenance .............................................................................................................................................123  
3.3.2.6 GPS Serial Port Diagnostics ................................................................................................................................124  
3.3.2.7 Fluxgate Serial Port Diagnostics..........................................................................................................................124  
3.3.2.8 MOVETO ............................................................................................................................................................125  
3.3.2.9 Fluxgate Calibration Procedure ...........................................................................................................................126  
3.3.2.10 Shake .................................................................................................................................................................127  
3.3.2.11 Configuration Item Record ................................................................................................................................128  
3.4 ALARM DISPLAYS ............................................................................................................................................129  
4.0 TROUBLESHOOTING....................................................................................................................................131  
4.1 LIMIT SWITCHES...............................................................................................................................................131  
4.2 MOTOR DRIVE..................................................................................................................................................132  
4.3 AUTOMATIC MOVEMENTS................................................................................................................................133  
4.4 GPS..................................................................................................................................................................133  
4.5 FLUXGATE COMPASS........................................................................................................................................134  
5.0 DRAWINGS & SCHEMATICS ......................................................................................................................135  
APPENDIX A - EXPERT ACCESS / RESET DEFAULTS CODE  
APPENDIX B - MOUNT SPECIFIC DATA  
APPENDIX C - DC MOTOR CONTROLLER  
The following appendices describe optional features of the RC3000. These appendices will be  
included in the manual if the option is present.  
APPENDIX REM - REMOTE CONTROL  
APPENDIX TRK - INCLINED ORBIT TRACKING  
APPENDIX DVB - INTEGRATED DVB RECEIVER  
APPENDIX DSI - ANTENNA DEPLOYMENT SAFETY INTERLOCK  
APPENDIX TLE - TWO LINE ELEMENT TRACKING  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.0 INTRODUCTION  
The RC3000 antenna controller is designed for use with elevation over azimuth antennas on mobile  
satellite uplink vehicles. The RC3000 assists both the technically-oriented and the non-technical operator  
of a mobile satellite antenna system by automating the process of locating and locking on to a particular  
satellite. This process can be time-consuming due to several factors. For each shoot, the antenna may  
be located in a different location, with its own local magnetic variation, and oriented in a different  
direction. Since the beamwidth of the antenna is extremely narrow, the elevation and azimuth pointing  
angles require a significant degree of accuracy to even be in the neighborhood of the satellite.  
The design and function of the RC3000 is derived from two other proven antenna controllers from  
Research Concepts Inc.: the RC8097 satellite locator and the RC2000C tracking antenna controller.  
This pedigree allows the RC3000 to automate all operational steps within one piece of equipment. First,  
a microcontroller based calculator function provides an accurate pointing solution through a collection of  
sensor data. The RC3000 then uses the data from the sensors to accurately steer the antenna to the  
calculated azimuth and elevation angles. The RC3000 also optionally automates the function of tracking  
inclined orbit satellites.  
PLEASE READ AND UNDERSTAND THE MANUAL. Due to the complexity of the functions performed  
by the RC3000, time invested in understanding its installation and operation will be well spent.  
1.1 Manual Organization  
This manual contains five chapters and multiple appendices. Each chapter is divided into multiple  
sections.  
This section (1.1) summarizes the contents of the remainder of the manual and the conventions and  
notations used throughout the manual. Section 1.2 highlights the functionality and features of the  
RC3000. Section 1.3 reviews the theory of the RC3000’s operation and should be understood before  
installation and initial use of the RC3000.  
Chapter 2 describes the installation and configuration procedures for the RC3000. The rest of the  
manual should be reviewed prior to installation in order to provide context for the installation procedures.  
Chapter 3 provides detailed instructions on the operation of the RC3000. This chapter will describe the  
data presented and user action required for every operational display screen.  
Chapter 4 covers RC3000 error conditions and provides help for system troubleshooting.  
Chapter 5 provides RC3000 schematics and drawings.  
The appendices provide additional support for working with the RC3000:  
Appendix A supplies the expert access codes on a single page, which at management’s discretion, may  
be removed to eliminate the possibility of inexperienced users inadvertently corrupting configuration data.  
Appendix B provides unique information for a specific mount or family of mounts. Please refer to  
appendix B now to note what paragraphs in the base manual are different for your mount.  
Appendix C provides information on the applicable motor controller for your mount.  
A test data sheet is included with the manual that accompanies a new RC3000 controller. The mount  
configuration of a particular controller is noted on the test data sheet.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
MANUAL CONVENTIONS  
Throughout the manual, representations of screens the user will see will be shown in the boxed format  
that follows:  
AZIM: 0.0 STOW SS1: 50  
MANUAL  
ELEV: -67.5 STOW SAT:TELSTAR 402  
POL: 0.0  
SPD:FAST  
CST  
<0-9>JOG ANTENNA <MODE>MENU  
14:25:47  
The following table shows typical abbreviations used both on RC3000 screens and in the manual’s text.  
ITEM  
Azimuth  
ABREVIATION(S)  
AZ  
AZIM, Azim  
Elevation  
EL  
ELEV, Elev  
PL  
Polarization  
POL, Pol  
CW  
CCW  
Clockwise  
Counter-Clockwise (Anti-Clockwise)  
Down  
DN  
Latitude  
Longitude  
LAT  
LON  
Satellite  
SAT  
GPS  
LCD  
AGC  
Global Positioning System  
Liquid Crystal Display  
Automatic Gain Control  
Satellite longitudes are presented in degree/decimal degree (79.0 W) format since that is the standard  
representation of satellite position. Latitude and longitude of the mount are presented in degree/minute  
(38°56 N) format.  
When referring to a particular RC3000 mode of operation, that mode’s name will be capitalized – ex.  
LOCATE.  
Throughout the RC3000 manual and software, the latitude, longitude and true heading of the mount are  
collectively referred to as the mount’s “position”.  
Movements of the mount are represented by graphing the azimuth and elevation axes as shown below.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.2 RC3000 Features  
The RC3000 antenna controller is designed to automate the operation of mobile (both vehicle mounted  
and deployable) mounts. Features provided include:  
- Automatic azimuth and elevation pointing solution calculation  
- Optional GPS receiver for determination of antenna latitude and longitude  
- Optional fluxgate compass for determination of antenna centerline heading  
- Optional automatic tracking of inclined orbit satellites  
- Automatic polarization control of rotating feeds  
- Battery backed-up non-volatile memory for storing satellite locations and configuration data  
- Automatic repositioning to stored satellites  
- Slim 2U rack mounted unit  
- Continuous monitoring of antenna drive status  
- Optional RS-422/-232 remote control interface  
- Support for C, Ku, Ka, L, X - band satellite operations  
- 4 row x 40 column Liquid Crystal Display (LCD) for user interface  
- 16 key keypad for data entry  
The RC3000 supports mounts from multiple antenna manufacturers and provides optional software  
configurations. When the RC3000 is powered on, the following identification screen appears for three  
seconds.  
RC3000A MOBILE ANTENNA CONTROLLER  
(c) RESEARCH CONCEPTS INC. 2004  
SHAWNEE, KANSAS  
SW:RC3K-P1-GTN  
(USA)  
913-422-0210  
version 1.44  
Hardware Configuration. There are two basic versions of the RC3000 hardware. The “A” version is  
configured with circuitry to support mounts with low voltage (12-36 VDC) DC motors. The “B” version  
supports higher voltage (40-120 VDC) DC motors. Other hardware configurations provide customized  
backpanel configurations, etc. Refer to the appendix B (mount specific data).  
In late 2004, internal board configurations changed. These changes did not affect interface definitions or  
software functionality. RC3000 units with serial numbers larger than 2000 contain the second generation  
boards. Typically, low voltage drive units with second generation board configurations may be referred to  
as "A2" units vs."A" which designates units with the original board configuration.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
Software Configuration. The software configuration (SW:) field is presented in the form RC3K-ab-xyz:  
RC3K-(Mount Manufacturer/Model #)-(Nav Sensor Option)(Tracking Option)(Remote Option)  
Descriptions of the software configuration designations are provided in the following tables:  
Mount Manufacturer/Model #  
The software within the RC3000 is customized to account for specifics of individual mounts. A particular  
mount is referred to by a two character designation with the first character typically associated with the  
mount manufacturer and the second character associated with a specific mount/antenna model from that  
manufacturer.  
CATEGORY  
Mount Manufacturer /  
Model Number  
DESIGNATION  
Letter / #  
DESCRIPTION  
Example: V1 – Vertex 2.4m. DMK  
S1 – SweDish 1.5m. DA  
A3 - AVL 1.2m. USA  
N1 - Andrew 4.5m. TriFold  
As of December 2005, the RC3000 supported over 80 different mount models.  
Navigation Sensor Options  
The RC3000 may be provided with multiple navigation sensor options. Navigation sensors allow the  
RC3000 to determine the mount's latitude, longitude and heading. If no navigation sensors are present,  
estimates of this data may be entered manually.  
CATEGORY  
Navigation Sensors  
DESIGNATOR  
DESCRIPTION  
N
G
A
No Navigation Sensors supported  
GPS & Fluxgate compass supported  
GPS, Fluxgate and integrated DVB  
receiver supported  
F
C
GPS and DVB receiver (no compass)  
GPS Compass  
Tracking Options  
The RC3000 may provide optional support for tracking inclined orbit satellites.  
CATEGORY  
Inclined Orbit  
Tracking  
DESIGNATOR  
DESCRIPTION  
N
T
E
Tracking not supported  
Step & Memory Track supported  
Step & Memory plus Two Line Element  
set tracking supported  
Remote Control Options  
The RC3000 may provide optional support for controlling the mount from a remote (away from the front  
panel) location.  
CATEGORY  
Remote Control  
DESIGNATOR  
DESCRIPTION  
N
R
O
P
No Remote Control Supported  
Remote Monitor & Control Supported  
Antenna Deployment Safety Interlock  
Both Monitor & Control and  
Deployment Safety Interlock  
NOTE: Descriptions of the optional features are typically provided by separate appendices.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.3 Theory of Operation  
The RC3000 performs its functions via digital and analog electronic equipment interfaced to the antenna’s  
motor drive and position feedback systems. This equipment is controlled through embedded software  
algorithms run by the RC3000’s microcontroller. This section provides an overview of the equipment,  
interfaces and major software functions.  
1.3.1 Controller Description  
The following figure is a block diagram showing the major components of the RC3000 :  
LIQUID CRYSTAL DISPLAY (LCD). The 4 row by 40 column LCD provides the user interface for  
monitoring the status of the RC3000 and for entering data.  
KEYPAD. The 4 row by 4 column keypad allows the user to enter data and commands to the RC3000.  
DIGITAL BOARD. The digital board is essentially a small computer containing a microcontroller,  
memory, real-time clock and circuitry to monitor and drive the keypad and LCD. The digital board  
performs the following major functions:  
- monitors user inputs from the keypad  
- displays information on the LCD screen according to controller mode, antenna status and user input  
- monitors antenna drive status  
- battery backs up non-volatile memory (configuration data, etc.) and the real-time clock  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
- performs communications between the microcontroller and the three (GPS, compass, remote control)  
serial channels  
- performs analog to digital conversion of drive position and signal strength inputs  
- performs automatic antenna movement algorithms (locate, stow, recall, track, etc)  
FEATURE BOARD. The feature board contains circuitry to implement many of the optional features of  
the RC3000. The feature board provides the following major functions:  
- signal drivers for PC remote control and navigation sensor serial communication  
- circuitry for multiplexing signal strength indications from 1 of 3 sources  
- circuitry for conditioning pulse based position feedback signals  
- power transformation to supply required voltages to other modules  
RF AUTOPEAK MODULE. This module accepts the output of an LNB (950-1450MHZ, -50 to –5dBm)  
and generates a signal indicative of power across the band. This signal may be used for autopeak  
operations.  
ANALOG BOARD. The analog board contains circuitry to control the antenna motors and condition  
antenna feedback signals. The analog board provides the following major functions:  
- generation of azimuth and polarization limit indications based on sensed potentiometer feedback  
- conditioning of elevation inclinometer input  
- conditioning of azimuth stow and elevation up/down/stow limit switch inputs  
- activation of relays (based on digital board control) to direct motor drive signals from the DC motor  
control module.  
DC MOTOR CONTROL MODULE. The solid state DC motor speed and reversing control module  
contains circuitry for antenna motor regulation. This module provides:  
- acceleration adjustment for smooth motor acceleration  
- deceleration adjustment for ramp down time when motor speed lowered  
- anti-plug instant reverse, solid state dynamic braking  
- current limiting circuitry to protect the motor against overloads and demagnetization and to  
limit inrush current during startup  
- IR compensation to improve load regulation  
POWER ENTRY MODULE. The power entry module allows the RC3000 to be configured for 115 or 230  
VAC operation.  
POWER TRANSFORMER. The power supply module transforms AC input voltage to a regulated DC  
voltage for use by the digital and drive boards.  
RESOLVER BOARD. To support mounts that use resolvers for position feedback, an optional resolver to  
digital conversion board may be added to the baseline RC3000 hardware.  
NOTE: Second Generation RC3000's (serial number > 2000) will have the circuitry of the analog board  
and the feature board combined. Section 5.0 will contain the appropriate schematics for a particular  
controller.  
1.3.2 System Interface Requirements  
The RC3000 is designed to interface with many different mobile antenna mounts. This manual attempts  
to describe installation and operation in a manner applicable to most mounts.  
The typical interfaces required for the RC3000 to perform all its automatic functions are described in  
section 2.2 (Electrical Connections). Known differences to these interfaces and how they are  
accommodated for a particular mount are described in appendix B (Mount Specific Data).  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.3.3 Operational Overview  
The RC3000 allows easy antenna operation via its menu based user interface. The screen displayed to  
the user is based on the current controller mode. Controller modes are divided into two major groups:  
operational and programming (see mode map in section 3.1.1). The operational modes provide for the  
normal operation of the antenna. The programming group provides for initial configuration of the  
controller and will typically not be used on a day by day basis. The following example highlights the basic  
modes of operation provided by the RC3000.  
Operational Group Functions  
MANUAL. In MANUAL mode the user may jog the antenna in azimuth, elevation and polarization. Upon  
power up, the fluxgate compass and GPS receiver initialize and begin providing data.  
AZIM: 0.0 STOW SIG: 50  
MANUAL  
ELEV: -67.5 STOW SAT:TELSTAR 402  
POL: 0.0  
SPD:FAST  
CST  
<0-9>JOG ANTENNA <MODE>MENU 14:25:47  
AUTOMATIC LOCATION OF A SATELLITE. In LOCATE mode, azimuth and elevation pointing angles  
are automatically calculated based on position (lat/lon), heading and the selected satellite. Position may  
be obtained automatically from the optional GPS, selected from a preset list of user defined positions or  
entered manually. Heading may be automatically obtained from the optional fluxgate compass or entered  
manually. The user selects which satellite to locate from either a preset user defined list of commonly  
used satellites, a provided extensive list of satellites or by manually entering satellite data. The RC3000  
checks that the calculated pointing solution is within the mount’s range of movement and prompts the  
user to automatically position the antenna.  
POS:  
SAT:GALAXY 6  
38°56N 94°44W 180.0  
74.0W  
LOCATE  
AZ:-31.1  
EL: 40.0  
<1>SELECT NEW SAT  
READY TO LOCATE  
STORING SATELLITE LOCATION. After verifying the antenna is precisely on the satellite, the user may  
STORE the satellite’s azimuth and elevation angles along with horizontal and vertical polarization data. If  
the satellite has been identified as having an inclined orbit, the TRACK mode will be automatically  
entered as described below.  
SAT  
LON INCLIN BAND  
STORE  
BRASIL A1 79.0 2  
C
VERIFY SATELLITE DATA OK FOR STORING  
1-CORRECT, 2-INCORRECT  
RECALLING STORED SATELLITES. The user may quickly and precisely move between previously  
STOREd satellites via RECALL mode.  
RECALL  
STORED SATELLITE: BRASIL A1  
SELECT SAT(SCROLL UP/DOWN) <ENTER>  
AUTOMATIC ANTENNA STOWING. From STOW mode, the user may ask for the antenna to be  
automatically moved to the stow position.  
AZIM: -42.5 ( 0.0)  
ELEV: 23.4 (-67.5)  
STOW  
MOVING TO (TARGET),<STOP> TO HALT MOTION  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
Programming Group Functions  
The programming group modes provide for initial configuration of the controller and also provide screens  
to aid in maintenance and troubleshooting of the controller.  
Configuration mode screens allow the user to customize and calibrate the operation of the RC3000 for  
use with a particular mount. Note that most configuration items will be factory set for correct operation  
with a particular mount.  
REF_VOLT:2.50 OFF: 0.0  
CONFIG-AZIM  
CCW:180 CW:180 SF:76.35  
SET REFERENCE VOLTAGE <2.00 - 3.00>  
Maintenance mode screens allow the user to monitor sensor inputs and perform periodic maintenance  
actions such as setting time and resetting drive errors.  
SYSTEM:11/10/97 22:26:40  
GPS UTC:11/10/97 22:26:40  
DISPLAY:11/10/97 16:26:40  
TIME  
ZONE:CST  
OFFSET:- 6  
1-DATE 2-TIME 3-SYNCH 4-ZONE 5-OFFSET  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.3.4 Antenna Pointing Solution  
The position (latitude and longitude) of the mount and the longitude of a selected satellite are required to  
calculate a pointing vector from the mount to the selected satellite.  
Given the mount’s latitude and longitude and the pointing vector to the satellite, the RC3000 calculates  
the elevation (with respect to local horizontal) required. Feedback from the inclinometer on the elevation  
axis will be used to move the mount to the required elevation.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
The azimuth portion of the pointing vector is calculated with respect to local true North. The fluxgate  
compass is used to determine the heading of the centerline of azimuth travel and the required movement  
in the azimuth axis is calculated.  
In the above example a true heading of 135 degrees to the satellite has been calculated. Based on the  
mount’s latitude, longitude and date, a local magnetic variation (see 1.3.8) of 10 degrees is calculated.  
The compass senses a magnetic heading of 55 for the azimuth reference direction. Applying the  
magnetic variation, this yields an apparent true heading of 45 degrees for the antenna reference  
direction. An azimuth movement of 90 (135 – 45) degrees clockwise is therefore needed to point at the  
satellite.  
Since a position sensor on the azimuth axis is always active, the RC3000's default displayed azimuth  
value is that of the antenna angle. Derived estimates of the magnetic and true heading of the mount may  
be selected in the MANUAL (3.2.1) and LOCATE (3.2.2.3) modes.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.3.5 Timekeeping  
There are several versions of time (system, sidereal, referenced and GPS) discussed within this manual.  
System time is maintained by the RC3000’s real time clock. The real-time clock is backed up by battery  
so that system time is available as soon as the RC3000 powers up. The system time is used to calculate  
sidereal time for maintaining track tables. Since satellite’s do not experience time shifts (such as from  
Standard Time to Daylight Savings Time or when moving from one time zone to another), it is  
recommended that system time not be modified while active track tables are present. If system time is  
changed, the information stored in track tables for inclined orbit satellites will no longer be valid.  
The RC3000’s system time is set to approximately Universal Coordinated Time (UTC) at the factory. It  
will vary from UTC due to the tolerance of the real-time clock.  
If the optional GPS receiver is installed, the RC3000 parses UTC from the data sent by the GPS receiver.  
This data is only available when the GPS receiver is sufficiently locked on to GPS satellites to determine  
UTC. The RC3000 allows the user to synchronize system time to the UTC reported by the GPS receiver.  
The period of a satellite’s motion is one sidereal day (approximately 23 hours 56 minutes 4 seconds).  
Entries in the track table for an inclined orbit satellite are stored at intervals of 1/48th of a sidereal day.  
The RC3000 determines at what point in a sidereal day (with respect to the RC3000 reference) it is by  
calculating how many sidereal days have passed from January 1, 1992 until the present system time.  
In several screens the RC3000 displays a reference time. The user may designate a three letter  
timezone designation and an hourly offset from system time. This allows the user to display local time or  
some other reference time without modifying system time. If system time is maintained close to UTC, the  
reference time displayed may be of use to operators for coordinating events.  
See section 3.3.2.3 for details on time maintenance.  
1.3.6 Drive System  
The RC3000 implements several mechanisms for the driving and monitoring of the azimuth, elevation  
and polarization axis.  
Position Sensing and Limits  
The RC3000 senses absolute axis position using feedback from various sensors (potentiometers,  
resolvers, inclinometer for elevation, etc). The sensed voltage is scaled appropriately for the particular  
mount. This sensed position is displayed in angular format.  
For systems requiring very small movements for inclined orbit tracking, the RC3000 also supports pulse  
feedback from the azimuth and elevation axis. Sensed pulses from the axis motor don’t provide an  
absolute indication of position but allow for very precise relative movements.  
The boresight of the antenna is displayed for the azimuth and elevation axis. In elevation, this angle is  
with respect to the local horizontal. In azimuth, this angle is with respect to the centerline of azimuth  
travel.  
The following diagram shows a typical range of movement for mobile satellite antennas. Note that  
elevation movement to the stow position is limited about a small range of azimuth movement in order to  
ensure safe stowing of the antenna.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
In the azimuth axis, movement in one direction is disabled when clockwise and counterclockwise limit  
switches are activated. There is also typically a region in the center of azimuth travel indicating that the  
azimuth axis is in a position that will allow for moving the elevation axis down to the stow position.  
In the elevation axis, there are typically three limit switches. The UP switch prevents further movement  
up. The “DOWN” switch delimits the elevation the mount may not move further downward unless it has  
been placed in the azimuth stow region. The STOW switch indicates when the mount has reached its  
furthest down position which is typically where the dish is stowed for travel.  
Jam and Runaway Sensing  
The RC3000 continuously monitors the axis positions to detect incorrect movement of the mount. If an  
axis has been commanded to move and the RC3000 does not detect movement within a prescribed time,  
the controller will declare a “JAM” condition and not allow further movement in that axis until the condition  
has been reset.  
Similarly if the RC3000 senses movement in an axis when no movement should be occurring, the  
RC3000 will declare a “RUNAWAY” condition. Like JAM, the RUNAWAY condition must be reset before  
further movement in the axis may occur.  
Anti-Reversal  
In order to save wear on the drive motors, the RC3000 limits how fast an axis may reverse its direction.  
This mechanism prevents a motor from instantly changing direction before coasting to a stop in the  
original direction. This mechanism is also useful for correct counting of pulses. Since the RC3000  
counts a pulse as being in the direction that the controller thinks the axis should be going, it is imperative  
to stop the motor completely before moving in the opposite direction.  
Automatic Movements  
In order to provide smooth automatic movement to target positions, the RC3000 utilizes several  
parameters to account for different mount characteristics.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
The Fast/Slow Transition parameter defines how far away from a target position the RC3000 will switch  
from fast to slow motor speed. The Coast Range defines where the RC3000 will de-energize the motor  
drive to allow the mount’s inertia to coast into the target position. The Max Error parameter defines how  
close to the target position will be considered good enough.  
Note that the DC motor control module in the RC3000 provides for smooth acceleration/deceleration, load  
regulation and dynamic braking of the motors.  
1.3.7 Polarization Control  
The RC3000 calculates the required position and automatically moves the polarization axis as part of the  
satellite LOCATE function. The following diagram shows the polarization axis sign convention used. The  
diagram depicts looking at the arc of satellites from behind the antenna.  
The RC3000 allows the user to specify the type of polarization axis mechanism present. If a circular  
polarization scheme is present, no automatic movement of the polarization axis is performed. If a linear  
polarization scheme is present, the RC3000 will calculate the theoretical position as a function of mount  
latitude, mount longitude and satellite longitude.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.3.8 Magnetic Variation  
In order to calculate satellite pointing solutions, the mount’s orientation with respect to true North must be  
known. The RC3000 uses the fluxgate compass to measure the local horizontal component of the earth’s  
magnetic field. The earth’s magnetic field is very irregular as shown in the following diagram from the  
National Geophysical Data Center.  
The magnetic field also changes slowly over time. The following table shows how the magnetic variation  
for Washington D.C. has changed over the last 250 years.  
YEAR  
1750  
1800  
1850  
1900  
1950  
2000  
MAGNETIC VARIATION  
-3.3  
-1.0  
-2.5  
-5.5  
-7.5  
-10.6  
To calculate the local magnetic variation (difference between magnetic North and true North), the  
RC3000 uses the International Geomagnetic Reference Field (IGRF) model. The IGRF is a mathematical  
model of the earth’s magnetic field and how it is changing. The IGRF is based on world wide  
observations and is updated every five years. The IGRF model cannot account for short term effects  
such as magnetic storms, etc.  
Local magnetic variation is calculated given the mount’s latitude, longitude and the current date. The  
magnetic variation calculation cannot account for isolated local anomalies (typically less then a few  
degrees). It also cannot account for local external effects (power lines, train tracks, etc). The autopeak  
scan functions (3.2.2.3.2.3) used by the RC3000 attempt to compensate for the small heading calculation  
errors that may occur at any particular location.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.3.9 System Performance  
The performance achieved by the RC3000 in locating and tracking satellites is dependent on the  
mechanical tolerances of the mount, the correctness of the installation and the accuracy of the various  
sensors.  
The largest source of error for the system is due to errors in determining the truck's magnetic heading.  
Errors in heading primarily affect the accuracy of the antenna's calculated azimuth position. The flux gate  
determines the magnetic heading by measuring the direction of the magnetic field at the sensor tower.  
Problems arise because the earth's magnetic field can be distorted by ferrous metals (such as steel and  
iron; aluminum is a non-ferrous metal) and man-made magnetic fields. These man-made fields can be  
generated by electric motors, generators, and transformers, as well as those "worked into" the coach  
body during manufacturing.  
For the flux gate sensor, there are two unique categories of objects that distort the magnetic field in the  
vicinity of the truck. Some of the distortion is due to objects and electrical devices on the truck itself. This  
component of the distortion can be largely compensated for during system calibration.  
The other component of the distortion is due to large metal objects and man-made magnetic fields around  
the site where the truck is being operated. This component of the distortion varies as the truck moves  
from one location to another, and it affects the accuracy of the calculated azimuth position. Environments  
which typically produce the largest errors include railroad yards, areas around electrical substations, and  
sites near structures containing large amounts of steel or iron, such as bridges or large buildings.  
To date, the largest known azimuth error due to these interactions is less than 10 degrees. To help  
alleviate this azimuth error, the Auto Peak feature scans an azimuth range about the target azimuth and  
seeks the strongest signal. This feature is explained in full in section 3.2.2.3.  
The RC3000 uses a 10 bit analog to digital converter for measuring voltages from azimuth, elevation and  
polarization potentiometers as well as measuring signal strength inputs. In most cases this provides  
adequate resolution but should be considered. For example, if the azimuth axis has 360 degrees of  
travel, the resolution achieved is 360 / 1024 (approximately 0.35 degrees). This example highlights why  
pulse or resolver sensors are used to make precise movements for inclined orbit tracking. The optional  
resolver interface uses a 16 bit resolver to digital converter. This allows resolution of 0.0055 ( 360 /  
65536) degrees.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 1  
Introduction  
1.4 Specifications  
RC3000A  
RC3000B  
Physical  
Size  
Weight  
19.0 inches x 3.5 inches x 17.5 inches  
19 lbs  
13 lbs  
115/230 VAC switchable 50/60Hz; 50W max 115 OR 230 VAC 50/60Hz; 50W  
Idle;850W max Antenna Moving; optional  
universal input  
max Idle;850W max Antenna  
Moving  
Input Power  
115 VAC, 8Amp Slow-Blow; 230 VAC,4  
AMP Slow-Blow  
115VAC and 230VAC, 12 AMP Fast  
Blow  
Fusing  
Temperature  
Humidity  
-20C to +50C  
0C to +50C  
35% to 85% (optional special-environmental kit available)  
Antenna Drive  
90VDC (3/4 HP max) for 115VAC,90  
or 180 VDC (1.5 HP max) for  
230VAC input  
12 VDC, 1 Amp max  
115 VAC 1Amp max (specify on  
order)  
Azimuth/Elevation  
Polarization  
Electromechanical  
Brakes (optional)  
Waveguide/Switch  
(optional)  
12-36 VDC, 10 Amps max  
12-36 VDC, 10 Amps max  
28 VDC 300mA, or 115 VAC 1Amp  
max(specify on order)  
24VDC 2Amps max or 115VAC 1 Amp max (specify on order)  
Position Sense  
Potentiometer, 10-bit resolution standard; optional single phase pulse sensors  
(Reed, Hall-Effect, Optical); optional resolver, 16-bit resolution  
Azimuth  
Inclinometer, 10-bit resolution standard; optional single phase pulse sensors (Reed,  
Hall-Effect, Optical); optional resolver, 16-bit resolution  
Elevation  
Polarization  
Potentiometer, 10-bit resolution standard; optional resolver, 16-bit resolution  
Five- 12 VDC inputs, standard: EL Up, EL Down, EL Stow, AZ Stow, Pol Stow.Four  
additional inputs optional, mount dependent  
Limit Switch Inputs  
Locate Mode  
Elevation Accuracy  
Azimuth Accuracy  
Polarization Accuracy  
GPS Lockup Time  
VSAT Mode  
+0.2 degrees (typical)  
+1.5 degrees (typical)  
+3 degrees (typical)  
0 seconds (when configured for accessory powered GPS receiver)  
Single key-press-to-locate-operation for untrained operators  
full L-Band power detection to find strongest signal.(configurable to AGC voltage or  
Beacon receiver output -15VDC to +15VDC; 2Mohm input impedance, two  
channels)  
Autopeak Input  
Modem Receive-Lock  
Input  
TTL or contact closure, (optional non-invasive modem lock detector available)  
Track Mode  
Antenna Size  
0.4 – 12.0 meters  
Tracking Accuracy  
Maximum Inclination  
0.1 to 3.0 dB selectable; mount dependent  
16 deg., standard  
Step-Track, Memory-Track, Intelli-Searchtm , Program Track, optional Ephemeris  
Track  
-15VDC to +15VDC; 2Mohm input impedance, two channels  
Tacking Modes  
Signal-Strength Input  
Non-volatile Memory  
Backup  
Duracell DL2450  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.0 INSTALLATION  
Proper installation is important if the full capability and accuracy of the RC3000 is to be realized. The  
procedures that follow will insure the optimum level of performance from all sensors and the system in  
general.  
Installation will be more efficient if each step in the physical installation and calibration be performed in  
the order in which it appears in the following schedule. Each step is referenced to a particular section of  
this manual, and should be checked off as it is completed. Coordination between the mount  
manufacturer, vehicle integrator and end user is required. Some steps are applicable only if the tracking  
or remote control options were purchased with the unit. The installation procedures are written to cover  
the most common mount installations. Some steps are slightly different according to the type of mount  
the RC3000 is interfacing to (see appendix B). Installation requires basic operational knowledge of the  
RC3000. Please review chapter 3 for information on how to navigate the RC3000’s screens and how to  
enter data.  
SECTION  
ACTION  
COMPLETE  
2.1 Equipment Mounting  
2.1.1  
2.1.2  
2.1.3  
2.1.4  
RC3000 Antenna Controller  
GPS Receiver  
Fluxgate Compass  
Inclinometer  
2.2 Electrical Connections  
2.2.1  
2.2.2  
2.2.3  
2.2.4  
2.2.5  
2.2.6  
2.2.7  
2.2.8  
2.2.9  
2.2.10  
2.2.11  
2.2.12  
2.2.13  
Power Entry  
Motor Drive  
Drive Sense  
Limit Switches  
Signal Strength  
Navigation Sensors  
Accessories  
RF Autopeak  
Hand Held Remote  
Pulse Sensors  
PC Remote Control  
Waveguide Switch  
Resolver Inputs  
2.3 Initial Configuration  
2.3.1  
2.3.2  
2.3.3  
2.3.4  
2.3.5  
2.3.6  
2.3.7  
2.3.8  
Software Initialization  
Elevation Calibration  
Azimuth Calibration  
Polarization Calibration  
Fast/Slow Motor Speed  
Pulse Sensor Checkout  
Drive System Checkout  
Navigation Sensor Communication  
2.4 Final Calibration  
2.4.1  
2.4.2  
2.4.3  
2.4.4  
2.4.5  
2.4.6  
Compass Calibration  
Azimuth and Elevation Alignment  
Signal Strength Adjustment  
Pulse Scale Factors  
Miscellaneous Adjustments  
Mechanizing Automatic Locate  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.1 Equipment Mounting  
This section describes the physical mounting requirements for the RC3000 and optional sensor units.  
Wiring requirements are discussed in section 2.2.  
2.1.1 RC3000 Antenna Controller  
NOTE: The RC3000 unit should not be installed in the rack until the final step of the Initial  
Configuration (section 2.3) because access to the interior of the unit may be necessary prior to  
that procedure. The cables may be run through the chosen location in the rack and connected to  
their respective components.  
The RC3000 enclosure is a standard rack mount chassis that occupies two rack units (2U). The front  
panel is mounted via four (4) 10-32 screws. Due to the length and weight of the RC3000, much strain  
can be put on the faceplate, particularly in a mobile unit. To help alleviate stress on the front panel  
mounting, additional mounting points accepting 10-32 and M4 screws are provided on each side, back  
and bottom of the unit. The user may use any of these additional mounting points to provide support for  
the RC3000 via strapping, shelving, etc. The additional mounting screws on the back of the unit may be  
also used to provide strain relief for cabling.  
CAUTION: support of the back of the RC3000 is a requirement. RCI’s warranty does not cover  
repair to units with ripped faceplates.  
The RC3000’s LCD is optimized for viewing from a 6 o’clock position. The optimum position to mount the  
unit would therefore be above the operator’s eye level.  
The following diagram shows the typical dimensions (in inches) of the RC3000. See appendix B for exact  
dimensions of your controller. See section 5 for a detailed depiction of the side mounting holes.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.1.2 GPS Receiver  
The optional GPS receiver (RC3000GPS) should be mounted in a position (such as the truck’s roof)  
where it has an unobstructed view of the horizon and sky. It should be mounted outside of the reflector  
when in a stowed position, with the connector (on the underside) towards the cable’s entry point into the  
truck. Care should be taken in the routing of the cable to avoid any problems.  
The GPS receiver should be mounted at least three feet from other antennas and electrical generating  
equipment. Strong RF interference from other sources may disrupt the GPS receiver’s signal reception.  
Wiring of the GPS connector is discussed in section 2.2.6.  
Recent RC3000s have been supplied with the GPS17 receiver model. The following diagram shows its  
dimensions.  
Earlier RC3000s were supplied with the GPS35 receiver model. The following diagram shows its  
dimensions.  
The GPS35 unit is supplied with 25 feet of cable. The GPS35 unit is supplied with a flange mounting  
bracket as shown above. An optional marine mounting bracket is also provided.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.1.3 Fluxgate Compass  
The optional fluxgate compass unit (RC3000FG) should be placed on the roof of the vehicle away from  
ferrous metals, electric motors, and any equipment that generates magnetic fields such as air  
conditioners, generators, and traveling wave tube (TWT) amplifiers. Experience has shown that the  
fluxgate performs best when mounted as high as possible on the vehicle. The fluxgate compass must be  
mounted in an upright position.  
Some mounts position the compass on the mount so that the compass may be lifted well above the top of  
the vehicle. If the compass is attached to the mount, the compass configuration item (3.3.1.2.1) must be  
set to the “antenna mounted” value.  
The RC3000 uses the fluxgate to determine the true heading of the mount’s azimuth centerline (0.0  
degrees azimuth). If the compass is not aligned in the direction of the azimuth centerline, that difference  
must be described in the azimuth offset configuration item (3.3.1.2.3). Some operators prefer to mount  
the compass pointing forward on the vehicle. If the mount faced rearward, an azimuth offset of 180  
degrees would need to be input.  
Refer to the drawing of the fluxgate enclosure to verify the proper orientation of the fluxgate. NOTE: An  
unhoused version of the compass is available for use in a user-designed enclosure.  
The Fluxgate Compass box may be either bracket mounted or flush mounted. Without the bracket it may  
be attached to a flat surface by four 10-32 screws from inside or outside the box through the four corner  
holes shown in the FRONT view diagram above. When using the bracket mount, it may be mounted with  
four 1/4 inch bolts using the holes shown in the bottom view of the bracket in the above diagram. The  
cable may be routed through either hole in the bracket. The circuit board may also be removed from the  
housing or an unhoused model is available on order for custom installations.  
The following method may be used to determine the best location for the compass.  
Park the vehicle in a location that is away from large metal objects or sources of magnetic fields. NOTE:  
for best results, the vehicle should be parked facing in an easterly or westerly direction. The  
vehicle's generator should be running, as well as all electrical equipment on the vehicle that generates  
magnetic fields.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
Stand on the roof of the vehicle with a standard magnetic compass. Slowly lower the compass to the  
proposed fluxgate mounting location on the vehicle without changing the orientation (or heading) of the  
compass body. If the needle of the compass swings as the compass is lowered to the mounting location,  
it is due to distortion of the earth's magnetic field by ferrous metals on the vehicle, or magnetic fields  
generated by the vehicle.  
The fluxgate should be mounted in the location where the needle of the compass experiences the  
minimum amount of swing as the compass is lowered to the proposed mounting location.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.1.4 Electronic Clinometer  
The electronic clinometer (also referred to as the inclinometer) should be positioned on the mount  
structure in an orientation that allows the inclinometer’s linear range of movement to rotate through the  
antenna’s RF boresight operational range.  
Determining the correct orientation of the inclinometer requires knowledge of the mount’s mechanical  
structure and the antenna’s RF offset. Typically the mount manufacturer will place the inclinometer in the  
correct position on the mount. See appendix B for the correct orientation for a particular mount.  
The elevation position sense circuit of the RC3000 is designed to interface to the Lucas/Schaevitz  
AccuStar model 0211 1002-000 or 0211 1102-000 inclinometers. The inclinometer’s position reference is  
marked on the body of the inclinometer. The inclinometer should be mounted such that the body of the  
inclinometer is rotated CW (as viewed by an observer looking at the front of the inclinometer) as the  
antenna’s elevation angle increases. The inclinometer must also be oriented properly on the antenna  
mount.  
To describe the orientation of the inclinometer, the term ‘elevation offset angle’ needs to be defined.  
Elevation offset angle is defined as the antenna’s RF elevation pointing angle (relative to horizontal) when  
a straight edge oriented vertically across the face of the antenna reflector (reflector top to bottom) is  
plumb. The inclinometer should be oriented so that, when the antenna reflector is plumb, the reference  
mark is deflected CCW (from the vertical position) by an amount equal to the 35 degrees minus the  
‘elevation offset angle’. If the inclinometer is attached as described the sensor will operate in its most  
accurate region for elevation look angles up to 80 degrees.  
The inclinometer mounting flange allows for some adjustment of the device’s rotational orientation. The  
mounting position selected for the inclinometer should allow for adjustment of the inclinometer’s  
orientation. The inclinometer should be mounted in a location such that it is protected somewhat from  
blowing rain.  
See section 2.2.3 for wiring of the inclinometer.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2 Electrical Connections  
This section provides cabling requirements for interfacing to the RC3000. Note that cables should be  
made long enough to allow the unit to be open while still connected to the system.  
The following sections supply a schedule of connection requirements. Note that the pinout requirements  
for J1, J3, J6, J7 and J10 are the same as required for RC8097 installations and therefore should not  
require rework of those cables for retrofitting to the RC3000. The following diagram shows the typical  
location of the backpanel connectors on original (serial # < 2000) controllers.  
Second Generation RC3000s (serial # > 2000) have a slightly different connector arrangement. For  
example, rather than having a single DB-37 for navigation sensors, the second generation controllers  
have individual DB-9s for each sensor. Any differences between original and second generation  
connectors will be described in the following paragraphs.  
Also, some versions of the RC3000 have customized backpanels to accommodate existing antenna  
connector schemes.  
See appendix B for your exact backpanel configuration.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.1 Power Entry  
J6 is an IEC male power connector on the backpanel for supplying AC power to the RC3000.  
The RC3000 is shipped from the factory with a line cord appropriate for the line voltage selected. If the  
line cord received with the unit is not appropriate for the power available at the installation site, the  
installer should check the controller to ensure that the proper line voltage has been selected.  
The RC3000A can be configured to operate on either 115 VAC or 230 VAC. The AC input voltage the  
unit is currently configured for is displayed in a window located in the fuse holder. To change the AC  
input voltage selection, remove the fuse holder and reverse the jumper assembly (on which the ‘115’ and  
‘230’ labels are located).  
To convert AC Voltage. Switch the power off at the front panel. Remove the IEC power cord from the  
back panel power entry module. With a small straight-blade screwdriver, remove the fuse drawer from  
the power entry module. With the same tool, remove the small plastic circuit card. Rotate the card so  
that the desired operating voltage will be displayed through the front of the fuse drawer and reinsert the  
card so that it firmly seats into the power entry module.  
NOTE: The RC3000B can only be configured for 115 or 230 VAC since the internal DC motor  
controller module is different for each voltage. The fuse holder is glued into the correct voltage  
position and cannot be modified as in the RC3000A case.  
The fuse holder is designed to accommodate 1/4” by 1 1/4” fuses. “Slow Blow” type fuses should be  
used. The following table shows the appropriate fuse for each model and line voltage combination.  
LINE VOLTAGE  
MODEL  
RC3000A  
RC3000B  
115 VAC  
8 Amp  
12 Amp  
230 VAC  
4 Amp  
6 Amp  
Some RC3000 units may be fitted with an optional card that automatically senses 115 or 230 VAC input.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.2 Motor Drive  
J7 is an MS3102A22-20S (Female on backpanel) connector, which terminates three motor cables. The  
minimum wire size for these cables is 16AWG.  
The RC3000A is designed to drive 12 to 36 volt DC azimuth, elevation, and polarization motors. The  
absolute maximum allowed motor current is 12 Amps. The RC3000A employs a built-in, solid-state motor  
controller (model 25A8 from Advanced Motion Controls). The motor drive module supports IR  
compensation, current limiting, dual speed operation, and dynamic braking. The drive train is also  
protected with resettable fuses.  
The RC3000B is designed to drive 90 volt (3/4 horsepower max) or 180 volt (1.5 horsepower max) DC  
azimuth and elevation motors. Ideally, 90 volt DC motors would be specified with 115 VAC input power  
and 180 volt DC motors with 230 VAC input power. 180 volt motors cannot be used with 115 VAC input  
power. The motor drive in the RC3000B is the model KBPB by KB Electronics . This motor drive  
supports IR compensation, current limiting, dual speed operation, and dynamic braking.  
The polarization drive of the RC3000B is designed to power a 12 volt DC motor which draws less than  
400 ma.  
The following table describes the polarity of the RC3000’s motor drive output signals.  
Axis  
RC3000 Connector  
Polarity  
J7 Terminals  
Azimuth  
G, F  
Azimuth CW – G has higher potential  
Elevation  
Polarization  
H, J  
A, B  
Elevation UP – H has higher potential  
RC3000A:Polarization CW – B has higher potential  
RC3000B:Polarization CW – A has higher potential  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.3 Drive Sense  
J1 (DB-15 Female on backpanel) receives position sense from the azimuth and polarization  
potentiometers and the elevation inclinometer.  
Normally, it is not necessary to modify the sensors on the antenna. The antenna manufacturer should  
insure that the antenna is compatible with the RC3000. This information is provided for informational  
purposes only.  
The directional sense of azimuth movement is defined as clockwise (CW) or counter-clockwise (CCW),  
as viewed by an observer located above the antenna. On the controller, CW movement results in a  
greater sensed azimuth position.  
The directional sense of elevation movement is defined as UP when the RF look angle of the antenna is  
increasing.  
The directional sense of polarization movement is defined as CW or CCW, as seen by an observer  
standing behind the antenna reflector looking ‘through’ the reflector at the satellite. See diagram in  
section 1.3.7 – Polarization Control. The reference position for the polarization position angle is  
vertical polarization for a satellite located at the same longitude as the antenna. In the northern  
hemisphere, for vertically polarized satellites to the west of the antenna, the polarization deflection is  
defined as CW relative to the reference position. In the northern hemisphere, the polarization angle  
increases for satellites farther to the west. In some modes of operation the controller predicts the  
polarization value required to align the antenna with a given satellite’s horizontal or vertical polarization  
position. For this feature to function properly the antenna’s polarization directional sense characteristics  
(defined by the polarization motor and position sensor) must be consistent with that of the controller.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.4 Limit Switches  
J3 (DB-15 Female on backpanel) connects to the azimuth stow, elevation stow, elevation up and  
elevation down limit switches.  
The + side of each limit switch circuit supplies 12 VDC. This 12 VDC supply is protected by a resettable  
fuse rated at 250 mA.  
The azimuth stow switch must be closed when at the azimuth stow position. If the azimuth stow limit  
switch cable is severed, the RC3000 will think that the azimuth axis is not at the stowed position. Logic  
within the RC3000 will not allow elevation to move below the elevation down limit switch if an azimuth  
stowed condition is not recognized.  
The elevation up switch must be open when the elevation axis has reached the up limit. If the elevation  
up limit switch cable is severed, the RC3000 will think that the elevation axis is at the up limit. Logic  
within the RC3000 will not allow the elevation axis to move up if an up limit condition is recognized.  
The elevation down switch must open when the elevation axis has reached the down limit. If the  
elevation down limit switch cable is severed, the RC3000 will think that the elevation axis is below the  
down limit. Logic within the RC3000 will not allow the azimuth axis to move when the elevation down  
condition is recognized.  
The elevation stow switch must open when the elevation axis has reached the stow position. If the  
elevation stow limit switch cable is severed, the RC3000 will think that the elevation axis is at the stow  
position. Logic within the RC3000 will not allow the elevation axis to move down when the elevation stow  
condition is recognized.  
NOTE: When the elevation stow limit is sensed, the RC3000’s hardware also internally generates an  
elevation down indication. To test the elevation down limit switch from the RC3000’s backpanel (pins 5 &  
6), pins 11 & 13 (elevation stow) must be jumpered to simulate a situation where the elevation axis is not  
stowed.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.5 Signal Strength  
J2 (DB-15 Female on backpanel) connects to receivers, modems, etc., to provide signal strength  
indication for autopeaking and tracking. J2 also supports 4 bits of digital I/O and various bus voltages that  
allow for future expansion.  
The received signal strength from the system receiver must be between –15 VDC and +15 VDC. The  
signal may be of either positive or negative polarity (see section 2.4.3 - signal strength adjustment).  
A shielded pair, such as Alpha 1292C, should be used to minimize external noise pickup on the signal  
strength line. The shield should be connected at the RC3000 system ground and open circuited at the  
receiver.  
The offset test points need to be made available (flying leads, etc) for use in the signal strength  
calibration step.  
Associated with J2 are offset and gain potentiometers for signal strength channels 1 and 2. These  
potentiometers are accessible via the back panel.  
The two signal lock inputs require TTL level (<0.8 VDC-low, >3.5VDC-high) signals. Signal_Lock 1 is  
associated with the AGC1 input (SS1) and Signal_Lock 2 with the AGC2 input (SS2). Either of the two  
signal lock inputs may be associated with a RF autopeak scan as described in section 3.3.1.2.5.  
The unregulated 24 VDC available at pin 9 may be used to provide DC bias to a LNB. This voltage  
supply is protected by a resettable fuse. Please consult Research Concepts Inc. for assistance if you  
wish to use this supplied voltage.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.6 Navigation Sensors  
J9 (DB-37 Female on backpanel) provides four RS-232 ports to connect the optional fluxgate compass  
and up to 3 GPS receivers. Route the cable away from electrically noisy devices (motors, air  
conditioners, etc.) to avoid unnecessary problems.  
Original RC3000s  
A DB-37 to two DB-9 Female cable is supplied for connecting to the GPS receiver and the Fluxgate  
compass. Pinouts for the third and fourth serial ports available from J9 are not shown as these ports are  
currently not used.  
The J13 DB-9 (Female on backpanel) connector (below the J7 drive connector) provides a “GPS loopout”  
interface. Another device (such as a TDMA modem) may listen to the output of the GPS receiver in order  
to obtain latitude, longitude, height, time, etc. The pinout of J13 is identical to the GPS DB-9 connector  
shown above.  
Second Generation RC3000s  
Rather than having the DB-37 connector, there is an individual DB-9 Female (J13) for the GPS interface  
and an individual DB-9 Female (J9) for the compass. The pinouts of these connectors will be as shown  
above for the DB9s.  
NOTE: the GPS loopout connector is designated J15 (DB9 Female on backpanel) on second generation  
RC3000s.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.7 Accessories  
J8 (9 pin DB-Receptacle) is an accessory connector. It contains pins that support the following functions  
of the RC3000: High-power-amplifier (HPA) disable, system alarm contact closure output, 1 pulse-per-  
second output (optional depending on GPS in-use), and a circuit that can allow for instant access to the  
GPS position solution. On some units, two of the pins may be diverted to power auxiliary equipment.  
The HPA disable is in a form-C contact arrangement with a normally-open, normally-closed and common  
contacts. While the antenna is below the down elevation limit or while the antenna is performing any  
large-scale auto-moves, such as deploy, locate, or stow, the normally-closed and common pins will be  
connected. After the auto-move is complete, the connection will be released.  
The Alarm output contact closure consists of a normally closed and a common contact. In the advent of a  
RC3000 mains power failure, the contact will close allowing an audible alarm or lamp to be lit.  
The instant GPS solution feature is realized by powering the GPS receiver(s) during transit to the shoot  
location and for a roughly 30 minute period after the vehicle ignition is turned off. Without this feature,  
GPS solution lock-up time will range from 2 to 4 minutes after RC3000 power up. The exact time  
depends on how long it has been since the receiver last had a solution and how far the receiver has  
moved from its last location.  
The Instant GPS feature requires a connection to the vehicle +12V battery system (+12V to +14V on all of  
the time), a connection to the +12V vehicle accessory voltage (+12V on while the vehicle ignition system  
is on), and a connection to the vehicle chassis ground. While the vehicle ignition system is on and for 30  
minutes after the ignition is shut off, power is routed to ports 1, 3, and 4 of the navigation sensor  
connector, J9. This feature must be enabled on the RC3000 feature board by installing diodes D31 and  
D29. The GPS receiver will typically draw less than 200 mA. at 12VDC.  
On certain units, when requested at the time of order, an unregulated power supply voltage can be made  
available on pins 2 and 8 of this connector at the expense of the instant GPS feature.  
Earlier RC3000 models mechanized J8 via a round Amphenol 126 series connector. Second Generation  
controllers put the HPA and alarm relays on a DB-25 (Female on backpanel) connector. The following  
table shows the pin connections for all connector types.  
DB- AMP DB- DESCRIPTION  
9
1
2
3
4
5
6
7
8
9
126  
25  
A
1
HPA Disable, normally-open, 3A @ 30VDC max or 3A @ 250VAC max  
B
+12 - +14V Vehicle Battery input (OR +Vunreg. for auxiliary output models, 2A  
max)  
Ground, Vehicle chassis ground input  
C
D
E
15 HPA Disable, common, 3A @ 30VDC max or 3A @ 250VAC max  
HPA Disable, normally-closed, 3A @ 30VDC max or 3A @ 250VAC max  
16 Alarm common, 3A @ 30VDC max or 3A @ 250VAC max  
3
F
H
J
4
Alarm normally-closed, 3A @ 30VDC max or 3A @ 250VAC max  
+12 to +14V Vehicle accessory input (Vunreg. Return for auxiliary output models)  
1PPS output, TTL compatible (only available GPS model 36 receiver)  
K
The other pins on the DB-25 connector are available for custom interface requirements. See Appendix B.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.8 RF Autopeak  
J11 (Type F Female connector on backpanel) is the input to the RF Autopeak circuit. This input accepts  
the output of an LNB (950-2150MHZ, -50 to –5dBm.)  
The RF autopeak module inside the RC3000 produces an output proportional to the broadband energy  
received. The RF autopeak circuitry includes a “DC block”. When this input is being used, it is indicated  
on RC3000 screens as the “RF” signal source.  
See sections 2.4.3.1 and 3.3.1.2.6 regarding use of the L-Band power detector input.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.9 Hand Held Remote  
J10 (DB-25 Female on backpanel) connects to the optional hand-held remote control (RC3000HRC)  
which allows antenna jog operations independent of the front panel. The remote control is housed in a  
3” x 6” x 1.75” aluminum case. The remote control should be connected to the RC3000 with a 25’ multi-  
conductor cable.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
The RC3000HRC places all of the antenna move functions and antenna limit indicators into the operator’s  
hand. The LEDs on the remote switch-pad indicate the antenna limit status:  
Azimuth Axis: STOW, CCW Limit, CW Limit.  
Elevation Axis: STOW, Up Limit, Down Limit.  
Polarization Axis: CCW Limit, CW Limit.  
When the COMP/MANUAL SELECT switch is at MANUAL, control of the azimuth, elevation and  
polarization axes is via the handheld remote panel. The SELECT and MOVE switches may then be used  
to configure and initiate movement of one of the three (azimuth, elevation or polarization) axes. Moving  
the switch back to the COMP position returns control to the RC3000’s frontpanel.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.10 Pulse Sensors  
NOTE: Pulse sensors are typically only installed on some mounts in order to mechanize the  
optional inclined orbit tracking feature. This section may be skipped if pulse sensors are not  
present.  
In order to obtain higher resolution azimuth and elevation axis position feedback, the RC3000 may use  
single phase pulse type sensors to determine the position of the antenna. A pulse type sensor produces  
a rectangular shaped waveform as the antenna moves about the axis associated with the sensor. A  
quadrature pulse type sensor produces 2 rectangular waveforms, one being 90 degrees out of phase with  
the other. With a quadrature type pulse sensor it is possible to determine which way the antenna is  
moving. The RC3000 software currently does not yet support quadrature sensors.  
The RC3000 controller counts the number of rising and falling edges of the waveform. The position count  
is decremented for counter-clockwise movement and incremented for clockwise movement. The  
waveform's high level should be 4.5 to 5.7 volts, and the low level should be 0.0 to 0.5 volts. The  
waveform's minimum high or low pulse duration should be at least 10 milliseconds. This means that  
pulses less than 10 milliseconds long may not be detected by the antenna controller. The maximum  
number of counts from the antenna's east limit to its west limit should be less than 65535. Remember,  
each rising edge and each falling edge of the sensor's output waveform is a separate count.  
Many large antennas use a sensor attached directly to each of the fundamental axis of the antenna. The  
sensor used may be a synchro, potentiometer, or a quadrature pulse encoder. A pulse type sensor  
attached to the fundamental axis of the antenna is not suitable for use with the RC1000A or RC2000A  
antenna controllers. When a rising or falling edge is detected on the antenna controller's sensor input,  
the antenna controller must determine whether to increment or decrement the position count. Since  
single phase pulse sensors are used, the antenna controller must determine which way the antenna was  
last commanded to move, and decrement or increment the count accordingly. With a pulse sensor  
connected directly to the antenna's fundamental axis, when the antenna vibrates back and forth due to  
wind, the pulse sensor produces a steady stream of pulses. The antenna controller will increment or  
decrement the count depending on which way the antenna was last commanded to move. In reality the  
antenna is just vibrating in the wind and not really moving. The result of this is an error in the position  
count maintained by the antenna controller.  
On a large antenna, the solution to the sensor dilemma is to place a sensor on the output of the motor.  
Most motors attach to the gear reduction systems via a C56 type flange. There are pulse sensors which  
may be placed between the motor and the transmission at this flange. Remember that any pulse sensor  
used must conform to the requirements of the antenna controller, which are: 1) the total number of rising  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
and falling edges must not exceed 65535, 2) the duration of the high and low segments of the waveform  
must be at least 10 milliseconds, 3) the high level of the waveform must be 4.5 to 5.7 volts, and 4) the low  
level of the waveform must be 0.0 to 0.5 volts.  
A number of manufacturers make sensors which may be placed directly between the motor and the  
transmission on the C56 flange; Dart's CF Series (ph. 317-873-5211) and Fenner's QRK 56C model (ph.  
612-424-7800) are two examples. Regardless of what type of sensors used, the user must ensure that  
the four requirements outlined above for the sensor waveform are met. Some signal conditioning circuits  
may be required to meet the waveform high and low level specification. Note that there is a 5.7 volt  
supply available on the back of the antenna controller. The maximum current draw from this supply  
should not exceed 200 milliamps. To insure that the pulse duration requirement is not violated, the user  
should consider the speed of the motor (RPM) and the number of pulses produced by the sensor for each  
revolution of the motor. To make sure that the total sensor waveform edge count requirement is satisfied,  
the user must determine how many revolutions of the motor are required to move from the east limit to  
the west limit (and from the down to the up limit) along with how many edges are produced for each  
revolution of the motor.  
J4 (DB-15 Male on backpanel) connects to the pulse sensors.  
*1 Sensor supply voltage may be configured via resistor changes for 5.79,8.07, 8.59, 10.11, 12.0, 14.94  
VDC (5.79 default). NOTE: Reed Switch type sensors do not require the pulse power (pins 10 & 14)  
signal.  
If reed switch sensors are used, each axis requires 2 wires in a shielded cable. If Hall Effect sensors are  
used, each axis requires 3 wires in a shielded cable. Shielded cables are required to minimize noise  
pickup which can result in antenna positioning errors.  
NOTE: SHIELDED CABLES ARE REQUIRED FOR THE POSITION SENSORS. THE SHIELDS MUST  
BE CONNECTED TO PINS J4-9 OR J4-15 ON THE BACK OF THE CONTROLLER AND MUST NOT BE  
CONNECTED AT THE ANTENNA.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
Position count errors due to improper use of the position sense line’s shield is one of the most frequent  
problems encountered during the installation of the RC3000. Here are the problems that are encountered:  
1) A shielded cable was not used for the position sense wires.  
2) The shield is not connected at connector J4 on the rear panel of the RC3000.  
3) The shield is connected to earth ground at the antenna. This results in ground currents flowing in the  
shield. The shield must not be connected to anything at the antenna.  
4) The insulator on the sensor cable is broken and the shield is grounded to something. As in #3, this  
results in ground currents.  
5) The sensor cable is spliced but the shield has not been spliced, or the shield is spliced but is also  
shorted to earth ground.  
See the troubleshooting (section 4) for more information on count problems.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.11 Remote Control  
J5 (DB-9 Female on backpanel) allows for optional remote control (RC3000CRC) of the RC3000. The  
RC3000 may be configured to communicate either by the RS-232 or the RS-422 / RS-485 standards.  
The RC3000 is shipped from the factory configured for RS-422/RS-485 operation.  
Original RC3000s  
To configure the RC3000 for RS-422 or RS-485, connect the remote control ribbon cable inside the  
RC3000 to connector J10 on the feature board. Jumper J12 on the feature board must be placed in the  
RS-422 position.  
To configure the RC3000 for RS-232, connect the remote control ribbon cable inside the RC3000 to  
connector J11 on the feature board. Jumper J12 on the feature board must be placed in the RS-232  
position.  
Second Generation RC3000s  
To configure the RC3000 for RS-422 or RS-485, set the J12 jumper on the analog board to the -422  
position and set jumpers X1 through X5 to the -422 position.  
To configure the RC3000 for RS-232, set the J12 jumper on the analog board to the -232 position and set  
jumpers X1 through X5 to the -232 position.  
Newer RC3000s also allow for the remote control to interface with an optional internal card hosting a web  
page. To configure the RC3000 for this, set the J12 jumper to the "RABBIT" position.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.12 Waveguide Switch  
J12 (DB-15 Female on backpanel) connects the optional waveguide switch (RC3KF-WG-DRV1) module  
to a waveguide switch of the type shown in the following diagram.  
Drive Out 1,2 provide 28 VDC to energize the waveguide switch.  
NOTE: The RC3000 (3.2.1.2) assumes the waveguide switch’s position 1 is the horizontal (H)  
position. If the H and V positions need to be reversed, both the position volts (9/10 and 14/15) and  
the position indicator (3 and 4) lines need to be swapped.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.2.13 Resolver Inputs  
Original RC3000s  
When the optional resolver input board (RC3000RSLVR) is required, J12 (DB15 Male on backpanel) is  
used for azimuth and elevation position information.  
Second Generation RC3000s  
Individual connectors (DB-9 Female on backpanel) are provided as needed for each axis.  
Suggested resolver cables would have three shielded, twisted pairs of 22 AWG (such as Belden 87777).  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.3 Initial Configuration  
Whereas Final Calibration (section 2.4) requires an open area with an unobstructed view of satellites,  
initial configuration may be done in any area (possibly a shop environment) where the antenna may be  
moved throughout its entire range of travel.  
At this point, the installer will have to start operating the RC3000 from the front panel. Section 3 will need  
to be reviewed to perform the steps described below.  
2.3.1 Software Initialization  
Initial Power Application. Before powering the unit on for the first time, please confirm that the input  
voltage the unit is configured for matches the intended input supply voltage. See section 2.2.1.  
Software Version Verification. When the RC3000 is turned on, a power up banner appears for 3  
seconds. This banner indicates the software options enabled in the RC3000’s EPROM and PLD. The  
software option data shown should be checked to confirm that all desired options are available. See 1.2  
(Controller Features) for a description of the various software options.  
Enable Expert Access. To perform RC3000 programming steps described below, expert access  
permission must be enabled. Expert access permission is enabled as the factory default, but may have  
been turned off if this is not the initial system configuration attempt. See 3.3.1.1.1 (Expert Access  
Permission) for description of how to view/modify the expert access configuration item.  
After installation is complete, expert access may be turned off to lessen risk of configuration settings  
being unintentionally modified. Disabling expert access will also present a less complex set of screens  
for normal operation.  
Reset System Defaults. The RC3000 is shipped with the default parameters set for the particular mount  
and software options. Most of the default values stored in non-volatile memory should be applicable. A  
few items (antenna size, etc) may not be initially set to values appropriate for a particular installation.  
Setting these values will be described next.  
If the RC3000 has previously been configured, the installer may want to reset the system defaults as  
described in 3.3.1.3.1. NOTE: the current value of all configuration items should be recorded prior  
to resetting system defaults.  
System Definition. The SYSTEM DEFINITION configuration screen (3.3.1.2.1) allows the user to  
indicate whether or not the optional GPS receiver is present, if and how the fluxgate compass is mounted,  
whether or not the optional waveguide switch module is present, the size of the reflector in use and what  
mode the user prefers the RC3000 to go to upon power up. The user may also enter the unit's serial  
number for later reference.  
GPS: 1  
CONFIG-SYSTEM  
COMPASS: 1  
SN:1234 WAVEGUIDE:0  
MODE: 2 ANT_SIZE: 120  
<1>GPS PRESENT <0>NOT PRESENT  
Follow the description in section 3.3.1.2.1 and set the SYSTEM DEFINTION items to the correct value for  
this installation.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
Azimuth/Elevation/Polarization Calibration. The next three steps calibrate the mount’s elevation,  
azimuth and polarization axes. Place the RC3000 in MANUAL mode. Values for the azimuth, elevation  
and polarization axes should be displayed, though they may not be reasonable since calibration has not  
yet been performed.  
For each axis, limit switch status will be confirmed, position feedback will be calibrated and total range of  
movement will be tested.  
NOTE: be careful when initially moving a mount since limit switches may not yet be configured  
correctly. In MANUAL mode, movement will stop whenever a particular jog key is released. The  
RC3000 may also always be turned off to stop movement.  
Throughout the 3 axis’ calibration procedures, two MAINTENANCE screens will be used extensively.  
One of the MAINTENANCE screens used is the Analog to Digital Voltage screen (see 3.3.2.1). This  
screen shows raw data coming from antenna position sensors (potentiometers and resolvers).  
AZ: 1.114 181.30 33004  
EL: 1.143 1 122.30 22264  
POL:2.237 181.30 33044  
AD VOLTAGES  
22.3 L1:1  
L2:1  
SIG: 3.756(1) <1>RF <2>SS1 <3>SS2 <4>GND  
Another MAINTENANCE screen that will be used is the Limits Maintenance screen ( see 3.3.2.5). This  
screen shows the current sensed state of limit switches for all three axes.  
AZIM CW:0 CCW:1 STOW:0 (0-OFF) LIMITS  
ELEV UP:1 DN:1 STOW:1 (1- ON) ACTIVE  
POL CW:0 CCW:1 STOW:0  
<BKSP>MAKE LIMITS INACTIVE  
<MODE>EXIT  
Before beginning axes calibration, the installer should become familiar with accessing these screens.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.3.2 Elevation Calibration  
Steps to perform elevation calibration will be described starting with the elevation axis in the stowed  
position.  
STEP 1.- STOW Limit Confirmation  
With the elevation axis in the stowed position, go to the Limits Maintenance screen (3.3.2.5) to confirm  
that the ELEV STOW and Down (DN) limits are active.  
Also confirm that the elevation UP limit is inactive. If the UP limit is active, the RC3000 will be prevented  
from moving the elevation axis up from the stowed position.  
If the initial state of the elevation STOW, DOWN and UP limits is not correct, check the limit switches and  
wiring (2.2.4).  
STEP 2. – Initial Movement  
The next action is to raise the antenna in elevation. Push the UP key from MANUAL mode. The antenna  
should rise. If not, check the polarity of the motor drive lines (section 2.2.2).  
As the elevation axis comes out of the stow position, the STOW limit should inactivate but the DOWN limit  
should remain active. This may be observed from the MANUAL screen by seeing the elevation “STOW”  
indication change to a “DOWN” indication.  
The elevation sensor should be mounted on the antenna so that the sense voltage produced at the  
sensor increases as the antenna is jogged upward. In MANUAL mode, when the EL UP (2) key of the  
RC3000 is depressed (and if the antenna moves up) the elevation position should increase (see section  
2.2.3).  
Note that the elevation position seen in the MANUAL screen might not initially change if the inclinometer  
is still outside of its operational range or if the inclinometer is mounted on a feedboom that doesn’t rise  
until the reflector has moved up a certain distance.  
The following steps will require values to be entered in the ELEVATION CALIBRATION configuration  
screen (see 3.3.1.2.2).  
REF_V:1.69 OFF: 0.0  
CONFIG-ELEV  
DOWN: 0 UP: 90.0 SF:50.00  
LOOK:1  
SET REFERENCE VOLTAGE <0.50 – 3.50>  
NOTE: the elevation offset item should be set to 0.0 before any further elevation calibration is  
performed. Any required elevation offset will be determined during the azimuth and elevation alignment  
step (2.4.2) as part of the final calibration steps. The LOOK configuration item is meaningful for only a  
small number of mounts (see appendix B). In most cases the value of this item is irrelevant.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
STEP 3a. – Inclinometer Reference Voltage  
To perform this step, raise the antenna until the reflector is in the reference position appropriate for this  
mount (see Appendix B). For the majority of mounts, the reference position corresponds to having the  
reflector’s face vertical. This angle can be confirmed by use of a level or digital inclinometer placed on a  
correct portion of the antenna structure.  
The elevation voltage shown on the AD VOLTAGES screen (3.3.2.1) should be near the target value for  
your mount as noted in appendix B. For the majority of mounts, this target voltage will be around 1.69  
volts. This voltage allows for the greatest range of linear feedback from the elevation inclinometer  
throughout the mount’s operational range. If not, loosen the elevation sense restraining plate and rotate  
the inclinometer until the elevation voltage is as near to the target voltage as possible. Secure the  
restraining plate and record the voltage.  
Recorded Elevation Reference Voltage ______________V  
Move to the Elevation Calibration configuration screen and enter the recorded value in the REF_V item.  
This will define to the RC3000’s software the voltage that should be seen when the elevation axis is in its  
reference position. To verify that data has been entered correctly, return to the MANUAL mode screen.  
The displayed elevation angle should be near the RF look angle offset of the reflector (see appendix B).  
STEP 3b. Elevation Resolver Reference  
NOTE: this step only needs to be performed for those mounts that incorporate a resolver sensor  
on the elevation axis.  
This step should be performed at the same elevation axis position as in step 3a. Additionally, the  
vehicle/platform should be level since the resolver will not compensate for tilt as the inclinometer does.  
Rotate the elevation resolver until a raw resolver angle of approximately 180.0 degrees in seen in the  
MAINTENANCE-VOLTS screen. Lock the elevation resolver in place and observe the raw resolver  
angle. Subtract this observed angle from the reflector’s RF angle and enter it as the elevation resolver  
offset (see 3.3.1.2.2).  
EXAMPLE  
Raw resolver angle at elevation reference position: 179.2  
Reflector’s RF angle at elevation reference position: 22.3  
Required elevation resolver offset: -156.9 ( 22.3 – 179.2)  
NOTE: on mounts equipped with an elevation resolver sensor, the elevation angle displayed when below  
the DOWN limit is derived from the resolver not the inclinometer. To perform a “sanity check” of the  
resolver calibration, move the reflector up and down around the point that the DOWN limit occurs. With  
the vehicle/platform level there should be very little discernable jump in the displayed elevation angle.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
STEP 4. Elevation Scale Factor Calibration  
This step is performed to characterize the output signal from the elevation inclinometer.  
1) With the elevation axis in the reference position, note the angle (using an accurate inclinometer  
placed on the mount itself not the angle displayed on the RC3000) and the A/D voltage at that  
point.  
Physical_Angle_1 (Reference) _______________Degrees  
Voltage_1 (Reference) ______________Volts  
2) Raise the antenna approximately 30 to 50 degrees and note the angle and voltage.  
Physical_Angle_2_____________ Degrees  
Voltage_2 ___________ Volts  
3) Calculate the output signal from the elevation inclinometer.  
Degrees/Volt = (Voltage_2 – Reference Voltage) / (Physical_Angle_2 – Reference_Angle)  
MilliVolts/Degree = Volts/Degree * 1000  
4) Enter the mV./deg. in the SF field of the configuration screen.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
NOTE: an alternate method for calculating the output signal from the inclinometer is to use the data  
supplied by the inclinometer manufacturer for each individual inclinometer and multiply by the gain  
(0.823) in the RC3000’s circuitry. (example: 59.27 mV/deg * 0.823 = 48.78 )  
STEP 5. Up Limit Confirmation  
Move the elevation axis to the UP physical limit and confirm that the “UP” limit is displayed in the  
MANUAL mode.  
Go to the Limits Maintenance screen (3.3.2.5) to confirm that the ELEV STOW and Down (DN) limits are  
inactive.  
If the state of the elevation STOW, DOWN and UP limits is not correct, check the limit switches and  
wiring (2.2.4).  
STEP 6. Software Elevation Limits  
The DOWN and UP elevation limit values in the configuration screen should be set to reflect the physical  
limits of elevation travel. Note that these limits don’t actually limit the elevation travel but are used by  
software during the LOCATE function to determine if a calculated pointing solution is outside of the  
mount’s range of movement. If a calculated pointing solution is beyond these limits, the message “ELEV  
RANGE ERROR” will be displayed in the LOCATE screen.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.3.3 Azimuth Calibration  
Steps to perform azimuth calibration will be described starting with the azimuth axis in the stowed position  
and the elevation axis above the DOWN limit. Movement in the azimuth axis is not allowed until the  
elevation DOWN limit switch is inactive.  
The mount should be moved to the exact azimuth position that it will be stowed. Typically this is near the  
midway point of its range of movement in azimuth. Also, the azimuth stow limit switch should be in the  
center of its activation region. It is very important that this position be confirmed in this manner or  
problems could be encountered during the automatic stow function.  
The following steps will require values to be entered in the AZIMUTH CALIBRATION configuration screen  
(see 3.3.1.2.3). NOTE: RES and REV items only appear if an azimuth resolver is present.  
REF_V:2.50 FG: 0.0  
CCW:180 CW:180  
RES:0.0 REV:0  
CONFIG-AZIM  
SF:65.62  
SET REFERENCE VOLTAGE <2.00 – 3.00>  
STEP 1a. Azimuth Potentiometer Reference Voltage.  
This step is applicable if the mount is fitted with a potentiometer to sense azimuth position. If the mount is  
fitted with a resolver, go to step 1b.  
Move to the MAINTENANCE MENU screen and select the AD VOLTS item. Voltage values read from  
the azimuth potentiometer can be read from the AD VOLTS screen (3.3.2.1).  
The azimuth voltage shown on the screen should be 2.5 +/- 0.1 volts (Since 5 volts is sent to the sensor,  
if the pot is adjusted at the center tap position correctly, the reading should be half). If the value is within  
this range, record it for later entry in the configuration items. If not, loosen the potentiometer restraining  
collar and rotate the shaft such that the displayed value is as near 2.50 volts as possible. Secure the  
collar and record the voltage.  
RECORDED AZIMUTH CENTER VOLTAGE______________ V.  
Move to the Azimuth Calibration screen and enter the recorded value in the REF_V item. This will define  
to the RC3000’s software the voltage that should be seen when the azimuth axis is in its centerline  
position. . To verify that data has been entered correctly, return to the MANUAL mode screen. The  
displayed azimuth angle should be 0.0 +/- 0.1 degrees.  
STEP 1b. Azimuth Resolver Reference Angle.  
NOTE: this step only needs to be performed for those mounts that incorporate a resolver sensor  
on the azimuth axis.  
Loosen and adjust the azimuth resolver to be as close to 180 degrees (seen at a/d volts screen 3.3.2.1)  
as possible. Lock the elevation resolver in place and observe the raw resolver angle. Subtract this  
observed angle from 0.0 and enter it as the azimuth resolver offset (3.3.1.2.3).  
After entering the azimuth resolver offset, the azimuth angle displayed in MANUAL mode should be 0.0.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
STEP 2. Initial Movement.  
The next step is to move the azimuth axis to confirm drive and sensor polarity. Azimuth clockwise and  
counterclockwise is defined as seen by an observer located above the antenna looking down on the  
antenna.  
In MANUAL mode, when the AZ CW (6) key of the RC3000 is depressed the antenna motors must be  
wired (see 2.2.2) so that the antenna moves clockwise.  
The azimuth potentiometer or resolver should be wired so that clockwise movement results in a higher  
azimuth position. When moving clockwise, the displayed azimuth position should increase.  
STEP 3. Stow Limit Confirmation.  
Move the azimuth axis clockwise and counterclockwise through the stow limit switch’s area of activation.  
Confirm that the STOW indication appears and disappears in MANUAL mode.  
Failure of the stow switch to deactivate would allow the reflector to potentially move below the elevation  
DOWN limit in an unsafe manner. If the initial stow limit does not function correctly, check the limit switch  
and wiring (2.2.4).  
STEP 4. Clockwise and Counterclockwise Limits.  
Discrete Limit Switches. Some mounts may mechanize azimuth clockwise and counterclockwise limits  
via actual limit switches. If this is the case, move the azimuth axis through its range of motion and verify  
that the CW and CCW limit indications appear in the MANUAL screen. After confirming these indications  
move on to the next step.  
Azimuth Electrical Limits. Other mounts may not have azimuth limit switches. In this case, the  
RC3000 allows for the CW and CCW limits to be set based on the azimuth potentiometer voltage.  
In this case, the antenna's azimuth electrical limits must be set. These limits are set using two  
potentiometers on the controller's analog board and thus it will be necessary to remove the controller's  
top cover. These two pots are labeled A-CW (azimuth clockwise) and A-CCW (azimuth counter-  
clockwise). These 2 pots on the analog board are accessed via holes in the feature board. Note that the  
Azimuth range limits specified below merely trigger the azimuth limit message and do not set the azimuth  
motion limits for the antenna.  
To set the azimuth clockwise limit, go to MANUAL mode and jog the antenna in azimuth to the desired  
azimuth clockwise limit. If the controller indicates that the azimuth clockwise limit is reached before the  
antenna reaches the desired position for that limit, the A-CW pot may have to be adjusted to allow the  
antenna to move. Adjust the A-CW pot until the azimuth limit indication flickers between CW and blank.  
To verify that the A-CW has been adjusted properly, verify that the antenna cannot move clockwise in  
azimuth but can move counter-clockwise.  
A similar procedure is used to set the azimuth counter-clockwise limit.  
STEP 5. Azimuth Scale Factor.  
NOTE: in most cases the default azimuth scale factor for a mount will be correct and should not  
be changed. Perform this substep only if appendix B suggests that the azimuth scale factor for  
your mount should be characterized.  
To calculate the azimuth scale factor, move the dish between two known physical azimuth positions and  
note the difference in the sensed azimuth voltage between the two locations. If definite reference points  
are available on the mount (+/-90 degree positions for example), these may be used. Otherwise use the  
difference in azimuth pointing solutions to two satellites. Record the azimuth voltage at the peaked up  
position of the two satellites.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
Example: at +90 degree reference position the azimuth voltage is 3.86. At the –90 degree reference  
position the azimuth voltage is 1.14. The azimuth scale factor is calculated as:  
180 degrees / (3.86 –1.14) = 66.16 degrees / volt.  
66.16 would be entered as the scale factor.  
STEP 6. Azimuth Software Limits.  
The CCW and CW configuration item values should be set to reflect the physical limits of azimuth travel.  
Note that these limits don’t physically limit azimuth travel but are used by software to determine if a  
calculated pointing solution is outside of the mount’s range of movement. If a calculated pointing solution  
is beyond these limits the message “AZIM RANGE ERROR” will be displayed in the LOCATE screen.  
STEP 7. Fluxgate Offset.  
NOTE: this item defines the difference in orientation (in the azimuth axis) between the fluxgate  
compass (2.1.3) and the azimuth reference (displayed 0.0) position. This value should initially be set  
to the apparent difference between the compass’ and azimuth axis orientations. For example, if the  
compass is placed on the vehicle facing forward and the dish actually faces backward, an azimuth offset  
of 180 would be entered. It is recommended that the compass be placed facing in the same direction as  
the azimuth centerline thus requiring an offset of 0.0.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.3.4 Polarization Calibration  
The following steps will require values to be entered in the POLARIZATION CALIBRATION configuration  
screen (see 3.3.1.2.4).  
REF_V:2.50 OFF: 0.0  
CONFIG-POL  
CCW: 90.0 CW: 90.0 SF:41.67  
TYPE:2 REF:1 H: -45.0 V: 45.0 AUTO: 1  
SET REFERENCE VOLTAGE <2.00 – 3.00>  
STEP 1. Polarization Type.  
Typically the default polarization type will be appropriate for a particular mount. If not, the type of  
polarization axis configuration must be specified as one of the following:  
Circular – no movement of the polarization axis is required. NOTE: if the polarization configuration is  
circular, the rest of the polarization calibration steps may be skipped.  
Single – If the polarization axis must be moved to distinct positions to orient with horizontal and vertical,  
the type is considered single.  
Dual – If the polarization system contains two feeds (or sets of feeds) such that the axis only has to be  
moved to one position to achieve both horizontal and vertical orientation, the type is considered dual.  
STEP 2. Polarization Reference Position.  
The polarization axis should be positioned so that it is aligned with the local vertical. Local vertical is  
considered the 0.0 polarization angle. Clockwise and counterclockwise is defined as seen by a person  
looking from behind the antenna out towards the arc of satellites. In MANUAL mode, when the Pol CW  
key is pushed the polarization axis must rotate in the clockwise direction as shown in the figure repeated  
from section 1.3.8.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
The following diagram shows a typical situation of two waveguides that rotate together. Note that the  
diagram should be considered as if the observer is behind the reflector looking towards the arc of  
satellites. This representation is relevant for both prime focus and dual reflector antennas.  
The polarity of a waveguide is determined by its narrow dimension. In the diagram, position A shows port  
1 as being at the 0.0 degree orientation. In position B, port 2 is at the 0.0 degree orientation.  
NOTE: before establishing the polarization reference position, the antenna platform must be  
leveled so there is no pitch or roll. Any platform pitch and/or roll present in this calibration step  
will later cause inaccuracy in automatic polarization movements.  
Using an accurate inclinometer or level, position the polarization axis so that the waveguides align with  
the local vertical and horizontal. Typically this position will also be close to the center or travel of the  
polarization potentiometer. If not, adjust the polarization potentiometer to achieve this value. Secure the  
pot and record the voltage read from the VOLTAGES maintenance screen (3.3.2.1).  
Recorded Polarization Reference Voltage ______________ V.  
Enter the recorded voltage in the REF_V configuration item. To verify that data has been entered  
correctly, return to the MANUAL mode screen. The displayed polarization angle should be 0.0 +/- 0.1  
degrees.  
STEP 3. Drive and Sensor Polarity.  
The polarization motor should be wired so that the polarization axis rotates per the convention shown in  
the above diagram. Jog the polarization from the MANUAL mode to confirm the correct rotation. If not  
correct, check the polarity of the motor drive lines (2.2.2).  
The polarization potentiometer must be wired so that the sensed polarization position increases as the  
Pol CW key is depressed. If not correct, check the sensor wiring (2.2.3).  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
STEP 4. Clockwise and Counterclockwise Limits.  
Discrete Limit Switches. Some mounts may mechanize polarization clockwise and counterclockwise  
limits via actual limit switches. If this is the case, move the polarization axis through its range of motion  
and verify that the CW and CCW limit indications appear in the MANUAL screen. After confirming these  
indications move on to the next step.  
Polarizaiton Electrical Limits. Many mounts do not have polarization limit switches. In this case, the  
RC3000 allows for the CW and CCW limits to be set based on the polarization potentiometer voltage.  
In this case, the antenna's polarization electrical limits must be set. These limits are set using two  
potentiometers on the controller's analog board and thus it will be necessary to remove the controller's  
top cover. These two pots are labelled P-CW (polarization clockwise), P-CCW (polarization counter-  
clockwise). These 2 pots on the analog board are accessed via holes in the feature board.  
To set the polarization clockwise limit, go to MANUAL mode and jog the antenna in polarization to the  
desired polarization clockwise limit. If the controller indicates that the polarization clockwise limit is  
reached before the antenna reaches the desired position for that limit, the P-CW pot may have to be  
adjusted to allow the feed to move. Adjust the P-CW pot until the polarization limit indication flickers  
between CW and blank. To verify that the P-CW has been adjusted properly, verify that the feed system  
cannot move clockwise but can move counter-clockwise.  
A similar procedure is used to set the polarization counter-clockwise limit.  
STEP 5. Polarization Scale Factor.  
NOTE: in most cases the default polarization scale factor for a mount will be correct and should  
not be changed. Perform this substep only if appendix B suggests that the polarization scale  
factor for your mount should be characterized.  
To calculate the polarization scale factor, move the feed between two known physical polarization  
positions and note the difference in the sensed polarization voltage between the two locations  
Example: at +90 degree reference position the polarization voltage is 3.86. At the –90 degree reference  
position the polarization voltage is 1.14. The polarization scale factor is calculated as:  
180 degrees / (3.86 –1.14) = 66.16 degrees / volt.  
66.16 would be entered as the scale factor.  
STEP 6. Polarization Reference Orientation Definition.  
The orientation achieved by placing the polarization axis in the reference position must be specified as  
horizontal or vertical. This choice will depend on whether the operator wants to refer to the receive or the  
transmit port when commanding the controller to move polarization to the horizontal or vertical position.  
The RC3000 uses this definition when automatically calculating the polarization angle for single port  
feeds.  
STEP 7. Additional Polarization Settings.  
Polarization Offset. This item describes any difference between the electrical and physical position of  
the polarization axis. In almost all cases the polarization offset will be 0.0. Offset might not be able to be  
characterized until final calibration.  
Default Horizontal and Vertical Positions. Preset locations for polarization horizontal and vertical  
positions (3.2.1) are entered for use in the MANUAL mode.  
Automatic Polarization Movement. Automatic movement of the polarization axis as part of the  
LOCATE function may be enabled/disabled by the AUTO configuration item.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.3.5 Fast/Slow Motor Speed  
The fast and slow output voltages for your particular mount will be set at the factory and typically will not  
need to be adjusted. On RC3000B models, there is only one fast/slow adjustment potentiometer on the  
analog board. On RC3000A models, there are fast/slow adjustment potentiometers for each axis on the  
auxiliary relay board next to the digital board.  
The slow speed for an axis should be set low enough that automatic movements perform smoothly. Care  
should be taken that slow speed is not set so low that the axis is prone to jamming.  
2.3.6 Pulse Sensor Checkout  
This step resets and tests the pulse sensor system. It is only applicable for controllers that have software  
options (such as inclined orbit tracking) requiring pulse feedback.  
The first step is to position the mount to the appropriate place for resetting the pulse count (see appendix  
B). After moving to this position initiate the pulse count reset from the DRIVE RESET maintenance  
screen (see 3.3.2.2).  
Next move the mount to the limits of azimuth and elevation travel and note the pulse count. The pulse  
count can be viewed from the MANUAL screen by pressing the Scroll Up/Yes key. Record the pulse  
count values at the four limits.  
Azimuth CW Pulse Count______________  
Elevation UP Pulse Count______________  
Azimuth CCW Pulse Count______________  
Elevation Down Pulse Count_____________  
At the Azimuth Pulse Drive (3.3.1.7) and the Elevation Pulse Drive (3.3.1.10) configuration screens, enter  
a value for the appropriate limit that is slightly within the recorded value. The value entered is within the  
recorded value to account for any slop limit switches may exhibit.  
NOTE that these pulse count limits are used by automatic movement routines such as tracking and spiral  
search to limit the area of an automatic pulsed-based movement. These limits are not the actual  
mechanism that will stop the mount’s movement.  
2.3.7 Drive System Checkout  
This step confirms the configuration of the drive system for all three axis. Manually move the mount to  
each axis limit and confirm drive current to the motor is shut off when the limit is reached. Also check the  
displayed position value and confirm that it is reasonable.  
Perform the STOW (3.2.2.2) and DEPLOY (3.2.2.3) functions and confirm the mount correctly stows and  
deploys.  
STORE (3.2.2.4) several dummy satellites and RECALL 3.2.2.5 them to checkout the automatic drive  
system. If the mount does not smoothly move to the target position, the drive parameters may have to be  
adjusted.  
2.3.8 Navigation Sensor Communication  
If the optional GPS receiver and/or fluxgate compass are present, confirm that valid serial data is coming  
from the unit(s). See the GPS COMM (3.3.2.6) or FLUX COMM (3.3.2.7) maintenance screen  
descriptions.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.4 Final Calibration  
The final calibration steps tune up the system for performing automatic location of satellites.  
2.4.1 Compass Calibration  
Ferrous metal on the vehicle distorts the earth's magnetic field in the vicinity of the vehicle. The flux gate  
indicates the direction of the distorted magnetic field. The flux gate calibration procedure provides a  
method to correct for this distortion (caused by the vehicle/platform) of the earth's magnetic field and  
obtain the vehicle's actual magnetic heading.  
Review the discussion of system accuracy in Chapter 1. Since the flux gate calibration only corrects for  
distortion of the magnetic field caused by the vehicle itself, it is important that the calibration take place in  
an area where the earth's magnetic field is not disturbed by structures or objects containing ferrous  
metals. Below is a listing of the characteristics of a good calibration site.  
1. Level ground, preferably higher than the surrounding area. Avoid low valleys.  
2. Free from structures containing a large amount of ferrous metal. It is of key importance to avoid areas  
adjacent to multi-story buildings, railroad tracks, bridges, truck yards, parking lots full of cars, and high  
voltage power lines.  
3. Trees and wooden objects pose no problem for calibration.  
4. Asphalt parking lots can provide a good calibration site. Care should be taken, though, in that asphalt  
is often laid over concrete which may contain reinforcing rod.  
If a particular location is questionable, walking around with a simple wet compass will often show whether  
magnetic irregularities are present. A good site is important since the overall performance of the Satellite  
Locator is only as good as its calibration.  
Section 3.3.2.9 describes how to perform the compass calibration procedure.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.4.2 Azimuth and Elevation Alignment  
This step attempts to discover and compensate for offsets in azimuth and elevation position sensing.  
Offsets may be introduced due to mechanical tolerances, slight inaccuracies in installation, etc. For  
example, the compass may not be exactly aligned with the azimuth reference position or the elevation  
inclinometer was not rigged perfectly.  
The alignment procedure relies on the fact that is it possible to determine how the dish is pointing based  
on the actual antenna angles required to intercept a satellite (at a known longitude) when the vehicle's  
latitude and longitude are known.  
NOTE: before performing this step, the elevation offset value should be set to 0.0.  
To determine the azimuth and elevation offsets, the vehicle is positioned at a number of different  
headings. At a given heading, the operator allows the controller to calculate the azimuth and elevation  
positions required to LOCATE a pair of satellites. These calculated positions are recorded. The operator  
then manually peaks the antenna to align the antenna with the satellites perfectly. The azimuth and  
elevation angles where the satellites are actually found are recorded. The difference between the  
calculated (or target) positions and the positions where the satellites were actually found are calculated.  
The results should be tabulated as shown in the table below.  
AZIMUTH  
CALC’D  
ELEVATION  
CALC’D  
HDG.  
1
SAT  
1
ACTUAL  
DIFF.  
ACTUAL  
DIFF.  
2
2
3
4
5
6
7
8
1
2
1
2
1
2
1
2
1
2
1
2
1
2
TOTAL  
AVG.  
NOTE: As many tests (different locations, etc.) as possible should be run to determine if  
consistent offsets are observed.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
Elevation Alignment  
It is fairly easy to observe errors in the elevation calibration.  
If test data shows that the actual elevation angle that a satellite is found is consistently above or below  
the calculated target, then it can be concluded that an elevation offset should be applied. Enter the  
appropriate value in the OFF field of the elevation calibration screen (3.3.1.3.2).  
If the difference between actual and calculated elevation angle is not consistently of the same magnitude,  
then the calculated elevation inclinometer scale factor should be questioned. Step 4 of the elevation  
calibration procedure should possibly be rerun.  
Also consider that a combination of elevation offset and inaccurate scale factor may be applicable. Rerun  
tests across the arc of satellites to confirm that applied corrections yield good results.  
Azimuth Alignment  
It is not as easy to observe errors in azimuth calibration. This is mainly due to the fact that the error from  
the compass reading will not be consistent from location to location and even from different vehicle  
headings at the same location.  
If, after multiple tests, a consistent error in actual vs. calculated azimuth target is observed, then a  
modification of the offset in the azimuth calibration screen may be applied.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.4.3 Signal Strength Adjustment  
The RC3000 can sense satellite signal strength via the L-band power detector (2.2.8) or the signal  
strength input circuits (2.2.5). This section describes how to configure the signal strength input circuits for  
use with the satellite receivers used for a particular installation. Correct adjustment of the signal strength  
circuitry is required for autopeak and tracking operations to peak up on a satellite.  
2.4.3.1 L-Band Power Detector  
The simplest detection scheme is to connect LNB output to the L-band power detector. For best results,  
insert inline attenuation or amplification so that the RF display is approximately 400 when the reflector is  
pointed at open sky.  
See section 3.3.1.2.6 (Autopeak configuration) for a discussion of the characteristics of the L-Band power  
detector.  
2.4.3.2 Signal Strength Channel  
To implement tracking algorithms and the LOCATE mode’s scan/search, the controller requires an input  
signal which indicates the strength of the received signal. Such a signal is generated within a satellite  
receiver, and is referred to as an AGC signal. (AGC is the abbreviation for Automatic Gain Control.) On  
satellite receivers, this signal may also be referred to as a 'Signal Strength' or 'Tuning Meter' output. An  
AGC output typically varies in proportion to the received power of the transponder which the receiver is  
currently tuned to.  
Signal strength indications from receivers, modems, etc. vary widely. The RC3000 provides two circuits  
that are designed to accommodate any signal strength input that varies between +/- 15 VDC. The 2  
circuits have the same design, but different component values installed optimize channel 1 for use with  
signal strength inputs that vary by less than 1.3 VDC. Channel 2 circuitry has a lower gain that would be  
more optimal for use with signal strength inputs that vary by more than 1.3 VDC. A particular  
installation’s unique set of receiver(s) will dictate which channel(s) are used.  
The following figure shows 2 examples of signal strength inputs that may be accommodated. Example A  
shows a signal strength indication that increases from –10 VDC when no signal is present (“Off Satellite”)  
to +13 VDC when the signal is strongest (“On Satellite”). With respect to the RC3000, this transition is  
termed positive polarity. Example B shows a signal strength indication that decreases as the received  
signal becomes stronger. This type of transition is termed negative polarity.  
The goal of this procedure is to transform the linear portion of the signal strength input into a 0 to 5 VDC  
signal for interpretation by the RC3000’s analog to digital conversion circuitry. This is accomplished by  
adjusting gain and offset pots for each signal strength channel on the back of the RC3000 and by  
specifying the polarity of the signal strength input via the signal strength configuration screen.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.4.3.3 Signal Strength Channel Calibration  
This section describes the calibration procedure for a single channel. If two channels are to be used, the  
procedure will need to be run for each. The procedure requires multiple steps and some steps are  
iterative. The procedure also requires the use of a voltmeter (preferably with a resolution of millivolts).  
Step 1. Align the antenna with a strong satellite of the proper frequency band. Place a voltmeter on the  
receiver’s signal strength output and record the voltage. The term “on satellite” will be used to refer to  
the antenna aligned (peaked up) with a strong satellite.  
ON SATELLITE VOLTAGE________________  
Step 2. Jog the antenna so the antenna is looking at nothing. Record the receiver’s signal strength  
voltage. The term “off satellite” will be used to refer to the antenna positioned well off of any satellite  
looking at nothing.  
OFF SATELLITE VOLTAGE_______________  
Step 3. Having recorded the On Satellite and Off Satellite voltages, go the SIG_ADJUST maintenance  
screen (3.3.2.4). Enter the two voltages and record the polarity and voltage offsets calculated by the SIG  
ADJUST screen.  
POLARITY_____________  
AGC1_OFFSET____________  
AGC2_OFFSET_____________  
Note that the SIG ADJUST screen will calculate voltage offsets for both channels and suggest which  
channel would be optimum for the entered On and Off Satellite voltages. Use the voltage offset for the  
channel determined to be used for this receiver (see discussion above).  
The calculated voltage offset will provide for the best transformation of signal strength input and will be  
used in step 6 below.  
Step 4. Go to the Signal Strength Factors configuration screen (3.3.1.2.5) and specify the polarity  
required for the channel (1 or 2) that is currently being calibrated. This information will be used by the  
RC3000’s software so that stronger signals will correspond to stronger indicated signal strength on the  
RC3000’s displays.  
Step 5. Go to MANUAL mode. Ensure that the channel that is currently being calibrated is displayed as  
the signal source. If not, select the channel as the signal source by using the SCROLL DOWN / NO key.  
Note that the displayed signal strength will currently be meaningless since the gain and offset calibration  
steps have yet to be accomplished.  
Step 6. Measure the offset voltage for the appropriate channel at the test point on connector J2 (refer to  
2.2.5). Adjust the OFFSET pot for the appropriate channel until the value calculated in step 3 is obtained.  
To increase the offset voltage turn the OFFSET pot clockwise (counterclockwise to decrease) when  
looking at the backpanel.  
Step 7. Move back onto the satellite. Observe the displayed signal strength on the manual mode  
screen. Adjust the GAIN pot for the appropriate channel until displayed signal strength of approximately  
650 is obtained. The direction to turn the GAIN pot to increase displayed signal strength is dependent on  
the characteristic of the signal strength input as indicated by the following table.  
ON SATELLITE VOLTAGE  
POLARITY  
Positive  
Positive (>0)  
CW  
Negative (<0)  
CCW  
Negative  
CCW  
CW  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
Adjusting the gain of the AGC channel in step 7 will modify the offset voltage in step 6. Steps 6 and 7  
should be run at least twice and possibly several times until the required adjustments are minimal.  
NOTE: When correctly adjusted, the displayed signal strength will be approximately 50 when “off”  
the satellite and approximately 650 when “on” the satellite. These values allow for conditions  
when the signal strength may be stronger than they were at the time of adjustement.  
Step 8. Set Thresholds  
Having observed the displayed value for signal strength, the user should set the autopeak threshold  
(3.3.1.2.6) and SS1/SS2 thresholds (3.3.1.2.5) for correct operation of autopeak and tracking operations.  
The signal strength system is now adjusted correctly for use by the autopeak and tracking functions. A  
common situation affecting signal strength measurement performance is discussed next.  
2.4.3.4 Amplifier Gain vs. Frequency Characterization  
An amplifier's gain vs. frequency characteristic, or gain flatness, is the variation of the amplifier's gain with  
changing frequency. The ideal response is to have a flat gain characteristic (the gain does not vary with  
frequency). Amplifiers with poor gain flatness characteristics can cause problems for the tracker. This  
section describes a simple test (no equipment required) that the user can carry out to check the receiving  
system's gain flatness.  
There are four places in a satellite receiving system that may have gain flatness problems that can affect  
the operation of the tracker. These are the LNB, the coaxial cable connecting the LNB to the receiver,  
line amps (or bullet amps) inserted in the 950 - 1750 MHz IF, and the receiver's IF or AGC stages. If a  
spectrum analyzer is connected into the receiver's block IF line, the gain flatness of the LNB and any line  
amps present can be observed. When the antenna is pointed away from any satellite, the spectrum  
analyzer displays the received noise, which should be constant with frequency. If the display is not a  
horizontal line then some gain variation with frequency is present.  
To understand how a poor gain flatness characteristic can cause problems, remember that the purpose  
of the signal strength input is to let the controller determine whether a satellite signal is present or not,  
and to provide relative signal strength information when peaking the antenna. A signal is assumed to be  
present whenever the input is above the threshold level for whichever band has been selected. When the  
receiver is tuned to various transponders, gain flatness problems could cause the signal to be above the  
threshold, when in fact no satellite signal is present. For certain transponders, gain flatness problems  
could also cause the controller's input scaling network to be saturated when the antenna is aligned with a  
strong satellite, making it impossible for the controller to detect changes in signal strength when  
attempting to peak the antenna.  
To test the gain flatness of the satellite receiver, perform the following procedure. The procedure  
assumes a single receiver, single frequency band system.  
1. Position the antenna well off of any satellite. Tune the receiver to each transponder. Make sure that  
the signal strength reading is below the threshold assigned via CONFIG mode.  
2. Align the antenna with a strong satellite. Tune the receiver to each active transponder on the satellite.  
Make sure that the signal strength is well above the threshold and below 999.  
If the system fails either of the tests above, then the user can either attempt to correct the problem by  
readjusting the GAIN and OFFSET pots (using the procedure outlined earlier), or by correcting the gain  
flatness problem. Most gain flatness problems can be traced to a problem with the coaxial cable  
connecting the antenna to the receiver (sometimes called a 'suck-out') or to bullet amplifiers. Some bullet  
amplifiers have been observed to have terrible gain flatness characteristics.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.4.4 Pulse Scale Factors  
The pulse scale factors specify the number of pulses counted per degrees (in radians) of movement for  
the azimuth and elevation axis. It is critical that these numbers are accurate since the tracking algorithms  
use them to determine step sizes (in pulse counts). Note that the RC3000 counts both rising and falling  
edges of the position pulses so that a single position pulse generates 2 position counts.  
NOTE: In the majority of cases, the antenna scale factors will have already been characterized for  
a mount and the appropriate values stored as defaults. The following procedures will only be  
required if a condition exists (different gear ratios, different pulse sensors, etc.) exists.  
The azimuth and elevation scale factors may be derived from the antenna mount manufacturer’s data or  
from data measured by moving the mount.  
SCALE FACTORS FROM MANUFACTURER’S SPECIFICATIONS  
If the antenna manufacturer gives the position pulses per degree specification for the antenna’s azimuth  
and elevation axis, simply multiply the value by 2 to obtain 'position counts per degree' (because the  
RC3000 counts both the rising and falling edges of the position pulses). Multiply this 'position counts per  
degree' value by 57.29 to obtain 'position counts per radian'. Round to the nearest whole number value  
to obtain the Elev Constant CONFIG mode item.  
Elev position pulses per degree _______ * 2 * 57.29 = _______ (position counts per radian)  
SCALE FACTORS FROM MOUNT MEASUREMENTS  
The elevation scale factor is obtained by moving the antenna in elevation over a known angle (as  
determined by an inclinometer) and obtaining the number of counts which corresponds to the angular  
movement.  
Here is the procedure:  
Step 1. Identify a location on the antenna to place the inclinometer. The location on the mount should be  
selected so that one degree of movement about the elevation axis registers as one degree on the  
inclinometer. It is best to use an inclinometer which has a magnetic base. These are available in  
hardware stores.  
Step 2. Record the elevation position count and the reading of the inclinometer. These will be  
designated CNT_1 and DEG_1, respectively.  
Step 3. Jog the antenna in elevation. It is recommended that the antenna be moved 15 to 20 degrees in  
elevation. Record the elevation position count and the inclinometer reading. These will be designated  
CNT_2 and DEG_2.  
The elevation region over which the measurements are made should correspond to the range of elevation  
angles which will be encountered in operation (i.e. the elevation values over which the satellites will be  
found).  
Step 4.  
Use the following formula to calculate the Elev Constant:  
( (CNT_2 - CNT_1) / (DEG_2 - DEG_1) ) * 57.29  
If the result is negative, change the sign to positive. Here is an example:  
Inclinometer  
Angle  
50.2  
29.8  
20.4  
Pulse  
Count  
32768  
541  
Higher Position  
Lower Position  
Difference  
32227  
(32227 / 20.4) * 57.29 = 9062 pulses/radian  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
The azimuth scale factor is obtained by noting the difference in the azimuth pointing solution angles  
between two satellites and the pulse counts when on the satellites. For best results, use satellites that  
are as far apart as possible and make sure you have positively identified the satellites.  
Example : Kansas City (38’56N,94’45W) heading of 180.0  
SATELLITE  
AZIMUTH POINTING PULSE  
SOLUTION ANGLE  
COUNT  
33333  
11000  
22333  
SPACENET 2 (69.0W)  
SATCOM C5 (135.0W)  
Difference  
-37.5  
53.4  
90.9  
(22333 / 90.9) * 57.29 = 14075 pulses/radian  
SCALE FACTOR FOR RESOLVER SYSTEMS  
The RC3000 uses the actual digitized resolver count in the same way it uses a pulse count. The RC3000  
utilizes a 16 bit resolver to digital converter which generates a count value from 0 to 65,535. Typically the  
resolver sensor rotates with the antenna. The resulting “pulse scale factor” therefore is:  
65536 reslover counts / ( 360 degrees * 1 radian/57.29 degrees) = 10430.2 “pulses” / radian  
The default scale factor for a resolver system is therefore rounded up to 10431.  
The constants are entered via the azimuth pulse drive (3.3.1.7) and elevation pulse drive (3.3.1.10)  
configuration item screens.  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 2  
Installation  
2.4.5 Operational Presets  
This section has been included in the outline because it may simplify the user’s day-to-day operation.  
The user cannot make use of preset truck locations or preset satellites if they are never entered into the  
memory. This is a straightforward procedure, but one which can be overlooked once the system is  
installed, since the RC3000 functions perfectly well without the presets. However, the presets streamline  
the operation by allowing the user to tell the program very quickly where the truck is, and what satellite is  
desired, without entering the data each time.  
If a list of user preferred satellites or truck locations are available, they may be entered as described in  
sections 3.3.1.1.2 and 3.3.1.1.3.  
2.4.6 Miscellaneous Adjustments  
LCD Contrast. An LCD contrast potentiometer (P2) is located on the RC3000 digital board. This  
potentiometer will be set at the factory, but the user may want to adjust its setting for a particular  
installation’s lighting conditions.  
Setting Time. Set the time, specify local time zone and offset per instructions for Time Maintenance  
(3.3.2.3.)  
2.4.7 Mechanizing Automatic Locates  
Performing all of the previous installation steps correctly should place the RC3000 into a state where  
automatic locating of satellites may be accomplished. This section discusses the typical final actions  
necessary to mechanize an automatic locate. The LOCATE mode is described in section 3.2.2.3.  
The first issue typically related to LOCATE performance is the pointing accuracy of the compass. The  
azimuth and elevation alignment calibration step (2.4.2) should be performed in order to fine tune the  
mount’s position sensing.  
Even with a well calibrated compass, local magnetic effects will cause the estimated mount heading to  
not be consistently perfect. Mechanizing the “autopeak” search movements described in sections  
3.2.2.3.3 and 3.2.2.3.4 will provide a way to compensate for the inherent variability in heading estimate  
performance.  
In order to mechanize the autopeak function, the RC3000 must be interfaced with the antenna system’s  
receiving equipment. The receiving equipment must provide a signal strength indication to the RC3000  
as a “positive identification” of the selected satellite during the autopeak function. Section 3.3.1.2.6  
describes enabling and configuring the autopeak function. Having selected a signal source, the  
characteristics of the signal must be described to the RC3000 via the signal strength configuration screen  
(3.3.1.2.5.)  
Many variations of receiving equipment exist. The following provides one example setup.  
Example Usage. Suppose an installation has a modem that generates a signal lock output but no  
relative signal strength output. An indication of relative signal strength may be obtained by inputting a  
RF signal (2.2.8) into J11. The modem’s signal lock output may be input to either pin 1 or 2 of J2 (2.2.5.)  
Program the RF LOCK item to indicate which signal lock input (1 or 2) is being used and what is the  
polarity (high or low) of the signal lock input. Program the RF TIME item with a large enough delay to  
ensure that a signal lock indication is generated by the modem before the autopeak scan operation steps  
past the satellite of interest.  
In the AUTOPEAK configuration screen (3.3.1.2.6), enable the autopeak function (ON:1) and set the  
signal source to RF (SIG:1.)  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.0 DETAILED OPERATION  
3.1 Operation Overview  
3.1.1 Modes  
The functionality of the RC3000 is achieved by placing the controller in the desired mode of operation.  
The figure shows the hierarchy of the RC3000’s modes. Each mode has a unique display screen that  
presents the information applicable to that mode’s operation.  
As the figure shows, there are two main groups of modes – operating and programming. Transitions  
between modes within a group are initiated via a momentary press of the Mode key, while a transition  
between the two groups requires the Mode key to be held down for three seconds.  
After installation, the programming group of modes will typically not be used for day to day operations.  
Sections 3.2 (operating modes) and 3.3 (programming modes) detail each mode.  
The rest of section 3.1 introduces common elements of all modes.  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.1.2 Keypad Usage  
The keypad provides a flexible method of controlling the functionality of the RC3000. While each  
RC3000 mode has different requirements for user input, the use of the keypad remains consistent  
throughout all modes.  
The keypad provides for both specific actions and general data input. As an example, the UP_2_N key  
initiates an antenna up movement while in MANUAL mode but also allows for the entry of the number 2  
when numeric entry is required or the indication of North when entering a latitude value. The required  
key usage is provided in the detailed description of each mode.  
NOTE: keypads on earlier RC3000s may not have included the exact nomenclature depicted above.  
Keypad usage has remained the same though for all RC3000s.  
The following table describes both the specific action and general data entry function of each key.  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
KEY LABEL SPECIFIC FUNCTION  
GENERAL FUNCTION  
Mode  
no specific function  
momentary push switches between modes  
within group  
button held for 3 seconds switches between  
operational and programming groups  
scrolls forward through lists  
provides YES answer to prompts  
scrolls backward through lists  
provides NO answer to prompts  
complete entry of data  
Scroll Up/  
Angle CT  
Scroll Dn /  
RF/SS  
Toggles between potentiometer and  
pulse az/el position display in Manual  
Toggles between RF/SS1/SS2 signal  
strength display in Manual  
Enter  
Heading Fix in manual  
select entry from list  
1 Pol CCW  
jogs polarization motor counter-  
clockwise when pol movement allowed  
jogs elevation axis up when in MANUAL  
mode  
jogs polarization motor clockwise when  
pol movement allowed  
supplies 1 for numeric entry *  
2 N  
El UP  
3
Pol CW  
4 E  
supplies 2 for numeric entry *  
supplies NORTH for latitude entry  
supplies 3 for numeric entry *  
move azimuth axis Counter ClockWise in supplies 4 for numeric entry *  
Az CCW  
MANUAL mode  
supplies East for longitude entry (123°45E)  
5
Commands Cross-Polarization  
movement in Manual, Store  
move azimuth axis ClockWise in  
MANUAL mode  
requests move to predefined Horizontal  
polarity position  
supplies 5 for numeric entry *  
H/V  
6 W  
Az CW  
supplies 6 for numeric entry *  
supplies West for longitude entry (123°45W)  
supplies 7 for numeric entry *  
signals current polarization value to be stored  
as the Horizontal value  
7
Sat-H  
8 S  
El DN  
jogs elevation axis down when in  
MANUAL mode  
supplies 8 for numeric entry *  
scrolls down during alphanumeric entries  
9
requests move to defined Vertical  
polarization  
toggles motor drive speed between  
FAST and SLOW  
provides way to stop automatic  
movements  
supplies 9 for numeric entry *  
Sat-V  
0
Speed  
. (decimal  
point)  
Stop  
supplies 0 for numeric entry *  
provides delimiter for various data entries  
decimal point for floating point entry ( 3.15)  
degree sign for lat/lon entry (38°56N)  
colon for time entry (12:34:56)  
slash for date entry (10/11/97)  
+/-  
BKSP  
provides way to exit out of certain  
conditions  
- Selects Waveguide Switch in Manual  
toggles sign of numeric data entry when  
cursor at beginning of entry field  
backspaces one field to the left during data  
entry  
* - numbered keys may also be used to select from a set of choices such as <1>LOCATE <2>STOW  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.1.3 Data Entry  
Many RC3000 screens request some type of user input. This section provides instructions on the entry of  
various types of data.  
Selection From List ( <0-9>SELECT )  
When the user is prompted to select an action from a displayed list, pressing the numbered key  
corresponding to the desired action will initiate the action.  
Scrolling Through List ( <SCR>THRU LIST )  
When the user is prompted to scroll through a list of items, pressing the Scroll Up/Yes key will move  
forward through the list and pressing the Scroll Dn/No key will move backward through the list. Pressing  
the Enter key when the desired item from the list is displayed will select the item.  
Alphanumeric Entry ( NAME:SATCOM K2 )  
To manually enter the name of a satellite or location, the user scrolls through the list of characters (A-Z,  
0-9 and blank) and selects the character by pressing the Enter key. To scroll forward through the list of  
characters use the 2/UP/N key and use the 8/DN/S key to scroll backward.  
Note: scrolling through the alphanumeric characters is not implemented via the Scroll Up/Yes or Scroll  
Dn/No keys since these keys will typically be used to move forward or backward through other fields from  
the field requiring alphanumeric input.  
After selecting one character, the flashing cursor is placed in the next space awaiting character selection.  
To complete the entry of the alphanumeric string, press Enter for a second time. The user may backup  
through the string by using the BKSP key.  
Integer Data Entry ( SIZE: 240)  
To enter whole numbers, use the 0-9 keys to enter the desired numeric string followed by the Enter key.  
Note that the data field will initially show the current value for the item until numeric entry is started. To  
terminate the entry without changing the value, the user may use the Scroll Up/Yes or Scroll Dn/No key.  
The BKSP key may be used to move back in the string to correct the input. When the input has been  
backed up past the first entry, the current value of the item will again be displayed. Pressing the Enter  
key with the current value displayed will also result in no update.  
Floating Point Data Entry (HEADING:180.0)  
Entering floating point values is very similar to entering integer values except that the decimal point is  
inserted by using the (decimal pt.) Stop key.  
Degree/Minute Latitude/Longitude Entry (TRUCK LAT:38°56N)  
Entering Latitude or Longitude is similar to entering a floating point value but the decimal point is used to  
place the degree sign delimiter. Following the degree sign, only values from 0 to 59 are valid since they  
represent minutes. After entering the numeric value of latitude or longitude, the user is prompted to  
supply W(est) or E(ast) for longitude or N(orth) or S(outh) for latitude.  
Degree/Decimal Longitude Entry (SAT LON:179.0E)  
This entry is similar to the degree/minute entry but allows decimal fractions of degrees. This format will  
be used for satellite longitude entry where the degree/minute format is standard for vehicle position entry.  
Time/Date  
Time is entered in HH:MM:SS format and date in DD/MM/YY format.  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.1.4 Display Layout  
The following screen shows many elements common to RC3000 mode displays.  
AZIM: 31561  
ELEV: 11060  
POL: -45.0 H  
SS1:625(Ku)  
SAT:BRASIL A1  
STEP:IDLE  
TRACK  
16:03  
WAITING FOR NEXT PEAKUP  
<0>MENU  
MODE TITLE: in the upper right corner the title of the current RC3000 mode is displayed – in this  
example TRACK designates that the RC3000 is currently in track mode.  
NOTE: if the mode title is proceeded by an exclamation point ( ! ), the mode was initiated by a remote  
command.  
DATA LABELS: since each mode presents a unique set of data, labels describing the data must be  
presented. The label will typically be followed by a colon to delimit between the label and the actual data.  
In the example shown, AZIM: is the label for the current azimuth pulse count.  
DATA VALUES: the current value of relevant data for the mode is displayed following the appropriate  
data label. In the example, the current azimuth pulse count (AZIM:) is 31561. Likewise the current  
satellite being tracked (SAT:) is BRASIL A1.  
USER PROMPTS: since each mode requires unique (but similar) keypad inputs, prompts for relevant  
user action are included on the fourth line to the extent possible. In the above example, <0> tells the user  
that pushing the 0 key will transistion the RC3000 to TRACK MENU mode. There are several types of  
user data inputs as described in 3.1.3.  
USER INFORMATION: when room allows, information about the current state of the RC3000 is  
displayed. In the above example, “WAITING FOR NEXT PEAKUP” describes the fact that since the  
RC3000 is currently in the IDLE portion of the STEP track operation the controller is waiting until the  
appropriate calculated time to perform the next peakup movement.  
TIME: in some modes where data (such as azimuth position) may not change for long periods of time,  
the current time is displayed to reassure the user that the RC3000 is functioning. In the above example,  
the current system time (16:03) is displayed with the colon flashing once per second.  
ALARM STATUS: while not shown in the above example, row 4 is used to display any alarm conditions  
the RC3000 has detected. The alarm message will alternate with the text normally on row 4. See section  
3.4 for more description of the alarm system.  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2 Operating Group  
Within the operating group of modes exists two high level modes – MANUAL and MENU. The MANUAL  
mode allows the user to manually jog the antenna while the MENU mode allows the user to select the  
modes that implement the RC3000’s automatic movement features. While in either one of these modes,  
a momentary push of the Mode key will transition the RC3000 to the other mode.  
POWER ON  
Upon powering up the RC3000, an identification screen is displayed for five seconds. The software  
version data is discussed in 1.2 (Controller Features).  
RC3000A MOBILE ANTENNA CONTROLLER  
(c) RESEARCH CONCEPTS INC. 2005  
SHAWNEE, KANSAS  
SW:RC3K-P1-GTN  
(USA)  
913-422-0210  
version 1.55  
MOUNT POSITION CONFIRMATION  
Following the power on screen, the RC3000 transitions to the appropriate screen based on whether or  
not a mount position (latitude/longitude/true heading) has been “saved”.  
If the mount’s position has been previously saved via the POSITION mode (3.2.2.7) or the STORE  
(3.2.2.4) mode, the following screen appears at power up requesting that the user confirm that this  
position is correct (i.e. the mount hasn’t moved since the position was saved). The SAVED MOUNT  
POSITION screen shows the position and the date and time that the position was saved.  
SAVED MOUNT POSITION  
38°56N 94°44W 218.1  
31DEC99 23:59  
<SCROLL UP>USE SAVED POSITION  
<BKSP>CLEAR POS (DELETES STORED SATS)  
If the saved position is still appropriate, pressing the Scroll Up/Yes key will instruct the RC3000 to  
continue to use that position. The RC3000 will use the saved position rather than attempting to  
automatically determine position.  
Note that using a saved position may be desirable because the position may have been previously “fixed”  
to account for the local compass inaccuracy, etc. Also the saved position may have been manually  
determined and inserted due to a possible navigation sensor (GPS receiver or fluxgate compass)  
malfunction. Using a saved position also allows the LOCATE mode to instantly begin calculating pointing  
solutions rather than waiting for the GPS receiver to form a navigation solution.  
If the user determines that the saved mount position is no longer appropriate (the mount has moved),  
pressing the BKSP key will invalidate the saved position. The RC3000 will then proceed to MENU mode.  
The LOCATE mode will automatically attempt to determine latitude/longitude from the GPS receiver and  
heading from the fluxgate compass. If the unit does not have the GPS and Fluxgate, control will pass to  
the POSITION mode.  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.1 Manual Mode  
AZIM: 0.0 STOW SS1: 50  
ELEV: -42.5 DOWN SAT:TELSTAR 402  
POL: 30.0 V SPD:FAST  
<0-9>JOG ANTENNA <MODE>MENU  
MANUAL  
CST  
14:25:47  
In MANUAL mode, the user may jog the antenna in all three axes. A momentary push of the Mode key  
will move the controller from the MANUAL mode to the MENU mode.  
AZIM:  
MAG:/mag:  
TRUE:/true  
The azimuth field shows a current position value of the azimuth axis. It also shows the status of azimuth  
limits (STOW, CCW, CW). The azimuth axis may be moved by pressing the Az CCW or Az CW keys.  
The value displayed may be changed by the Scroll Up/Angle CT key. The display will rotate between  
showing antenna angle, antenna pulse count, magnetic heading and true heading values. When first  
entering MANUAL mode, the field will always be initialized in the display mode selected by the  
initial_azimuth_display configuration item (3.3.1.2.3).  
The magnetic and true heading values are derived by taking the current heading estimate of the mount  
(see the LOCATE function) and adding the antenna angle. If there is currently no mount heading  
estimate, the field will display "-------". If the current heading estimate has not been "fixed" (either  
manually or automatically by the DVB receiver function), the field will be annunciated by small letters  
(mag: or true:) to indicate that the heading value may be inaccurate due to compass error. If the  
RC3000's heading estimate has been "fixed", the field will be annunciated in capital letters (MAG: or  
TRUE:) to indicate confidence that the value represents an accurate magnetic or true heading.  
ELEV:  
The ELEV field shows a current position value of the elevation axis. It also shows the status of elevation  
limits (STOW, DOWN, UP). The elevation axis may be moved by pressing the El Up or El DN keys.  
NOTE: when the azimuth field shows a pulse count value (due to pressing of the Scroll Up/Angle CT  
key), the ELEV field will also show the current elevation pulse count. During the other three choices of  
azimuth display, the field will show the elevation angle derived from the inclinometer.  
Following a LOCATE operation, the azimuth and elevation limit fields will display the target angles in  
parenthesis. If a limit condition is active, the limit display will overwrite the target values.  
POL:  
This field shows the current angular value of the polarization axis along with its limits (CCW, CW). This  
field will also show if the polarization axis has been placed at a predefined horizontal (H) or vertical (V)  
position. An asterisk (*) placed before the POL label indicates that the proceeding LOCATE function  
calculated that a waveguide switch “flip” will have to occur.  
The value of the predefined horizontal and vertical positions depends on what mode was active prior to  
entering the MANUAL mode. If a LOCATE operation occurred prior to MANUAL, the H and V values will  
be those automatically calculated by the LOCATE mode. Otherwise H and V depend on whether or not  
satellites have been STOREd. If MANUAL was entered following a RECALL operation, H and V will be  
those stored for the RECALLed satellite. If multiple satellites have been STOREd, H and V will  
correspond to the values for the closest (in terms of azimuth location) STOREd satellite. If no satellites  
have been STOREd, H and V will be that of the default horizontal and vertical positions set by the user.  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
The polarization axis may be moved manually be pressing the Pol CCW or Pol CW keys. The axis may  
also be moved automatically to the predefined horizontal or vertical positions by pressing the H or V keys.  
In the MANUAL mode, whenever the “5 H/V” key is pressed the polarization axis will automatically move  
90 degrees from its current position. The target position for this automatic “cross polarization” movement  
takes into account the user defined polarization axis limits. For example, if a cross polarization movement  
of 90 degrees clockwise will move the axis beyond the clockwise limit, the movement will be achieved by  
moving 90 degrees counter-clockwise.  
SS1/SS2/RF:  
This field shows the current signal strength sensed on the selected signal strength channel. By pressing  
the “Scroll Dn RF/SS” key the source of signal strength will rotate between signal strength channel 1  
(SS1), signal strength channel 2 (SS2) and the RF autopeak input (RF).  
The current signal strength will be displayed as a value between 0 and 999 (see 2.5.3 Signal Strength  
Adjustment). If the selected signal source is saturated (value greater than 999), *** will be displayed.  
If a signal lock input has been enabled associated with RF, SS1 or SS2, an “L” will be displayed to the  
right of the signal strength value whenever the signal lock condition has been satisfied.  
SPD:  
This field shows the selected drive speed. The speed may be toggled between FAST and SLOW by  
pressing the Speed key.  
SAT:  
This field shows the name of a satellite. The satellite shown depends on which of the following actions  
occurred most recently:  
1) if an automatic LOCATE of a satellite was performed, the selected satellite’s name will appear in  
lowercase letters (brasil a1). This is to indicate the RC3000 has moved to where it believes the  
selected satellite is located. The name is in lowercase letters to remind the user to positively identify  
and peak up on the satellite before storing.  
2) If during manual jogging of the antenna, the azimuth and elevation approach a position where a  
satellite has been stored, the stored satellite’s name will appear in lowercase letters when the  
antenna is in the general vicinity and in uppercase letters when the antenna is almost exactly in the  
position the satellite was stored.  
3) Following a RECALL of a stored satellite, that satellite’s name will appear in uppercase letters until  
the antenna has been moved enough for case 2 to apply.  
TIME DISPLAY  
MANUAL mode will display the reference time (1.3.5) and time zone in the lower right hand corner.  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
AUXILLARY FUNCTIONS  
According to the RC3000’s configuration and current conditions, several additional functions may be  
initiated via the MANUAL mode.  
3.2.1.1 Heading Fix  
From the MANUAL mode the user is given the ability to correct the mount’s true heading based on where  
the selected satellite is found. This HEADING FIX capability is available when all of the following  
conditions are true:  
1) MANUAL mode was automatically entered following a LOCATE  
2) The selected satellite is geostationary (inclination = 0 )  
3) The mount’s position has not already been saved  
4) The RC3000 is equipped with the GPS and Fluxgate compass options  
When the above conditions are present, the “<0-9>JOG ANTENNA” message will alternate with a  
“<ENTER>FIX HEADING” message. The user should positively identify that he is on the selected  
satellite (the satellite named in the SAT: field) and then manually peak up in azimuth and elevation.  
When the Enter key is pushed the MANUAL mode will switch to the following screen.  
PREDICTED AZIM: -50.9  
CURRENT AZIM: -48.7  
DIFFERENCE: 2.2  
HEADING FIX  
SAT:galaxy 7  
<BKSP>APPLY DIFF. TO HEADING <MODE>EXIT  
The HEADING FIX screen shows the name of the selected satellite in the SAT: field. The PREDICTED  
AZIM field shows the target azimuth originally predicted by the LOCATE function based on the mount’s  
current position. The CURRENT AZIM field shows the where the user peaked up on the satellite while in  
MANUAL mode.  
The DIFFERENCE field shows the value obtained by subtracting the predicted azimuth from the current  
azimuth. This difference should reflect the error in the mount’s true heading currently in use. Pushing the  
BKSP key will apply the difference to the mount’s heading for use in subsequent LOCATE operations. In  
the above example, if the current true heading of the mount was 195.0 it would be “fixed” to 197.2.  
NOTE: to make this “fixed heading” persist through the next powering down of the RC3000, the mount’s  
position would need to be “saved” via the POSITION mode. If the difference is applied, the RC3000 will  
proceed to the POSITION screen.  
If the user is unsure that applying the difference is the correct thing to do, pressing the Mode key will  
return the RC3000 to the MANUAL mode.  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.1.2 Waveguide Switch  
For mounts equipped with the optional waveguide switch control module, manual control of the  
waveguide switch may be initiated via the MANUAL mode.  
NOTE: The WAVEGUIDE SWITCH configuration item on the System Definition screen (3.3.1.2.1) must  
be set in order for software to allow the changing of the waveguide switch position from the Manual  
mode.  
When a waveguide switch is present, the Manual mode screen appears as shown below:  
AZIM: 0.0 STOW SS1: 50  
ELEV: -42.5 DOWN SAT:TELSTAR 402  
POL: 30.0 V SPD:FAST WAVE:H CST  
<0-9>JOG<BKSP>WAVE <MODE>MENU 14:25:47  
MANUAL  
WAVE:  
This field shows the currently sensed position of the waveguide switch. “H” denotes the horizontal  
position, “V” the vertical, “?” indicates that neither position is sensed and “*” indicates that both H and V  
are sensed (probably an error condition).  
Pressing the BKSP button will toggle the switch position. During the switch transition, a “+” will be  
displayed when going to the H position and a “-“ will be shown while going to the V position. Note that  
after 5 seconds the switching operation will timeout and drive voltage will be stopped if the desired  
position has not been sensed.  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2 Menu Mode  
MENU mode allows the user to select one of listed modes. Pressing the Mode key will move to MANUAL  
mode. Note: RECALL and DELETE will not be displayed if no satellites are currently STOREd.  
1-DEPLOY 2-STOW 3-LOCATE  
4-STORE 5-RECALL 6-DELETE  
MENU  
7-POSITION 8-SETTINGS  
CST  
<0-9>SELECT <MODE>MANUAL  
14:37:23  
MENU mode displays the reference time and time zone in the lower right hand corner.  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.1 Deploy  
The DEPLOY mode automatically moves to the mount’s predefined “deploy” position. See appendix B for  
the list of deploy positions for the various mounts supported. The deploy command requires an explicit  
confirmation in order to initiate antenna movement.  
<MODE> MENU (DO NOT DEPLOY)  
<BKSP>CONTINUE DEPLOY  
DEPLOY  
Pressing the BKSP key will initiate the DEPLOY movement. If the DEPLOY mode was inadvertently  
entered, pressing the Mode key will return to the MENU mode without initiating antenna movement.  
AZIM: 0.0 ( 0.0)  
ELEV: -42.1 ( 22.3)  
POL: -56.7 ( 0.0)  
MOVING TO (DEPLOY)  
DEPLOY  
<STOP>HALT MOTION  
As each axis moves, its label (AZIM/ELEV/POL) will flash and the current position will update. The target  
deploy positions will be displayed in parenthesis. The sequence of axis movement will be mount  
dependent.  
Following completion of movement to the deploy position, the RC3000 will return to MANUAL mode. The  
automatic movement may be terminated anytime by pressing the Stop key.  
The azimuth, elevation and polarization deploy positions are defined in the Stow/Deploy configuration  
screen (3.3.1.3.10).  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.2 Stow  
The STOW mode automatically moves to the mount’s predefined “stow” position. See appendix B for the  
list of stow positions for the various mounts supported.  
Like the DEPLOY mode, STOW requires an explicit confirmation to initiate movement.  
<MODE>MENU (DO NOT STOW)  
<BKSP>CONTINUE STOW  
STOW  
After initiation a sequence of movements will be performed to stow the antenna. The sequence of axes  
movements will be mount dependent. As each axis moves, its label (AZIM/ELEV/POL) will flash and the  
current position will update. The target stow positions will be displayed in parenthesis.  
AZIM:-123.4 ( 0.0)  
ELEV: 55.1 ( -67.5)  
POL: -56.7 ( 0.0)  
MOVING TO (STOW)  
STOW  
<STOP>HALT MOTION  
The following describes a typical sequence of movements:  
- the azimuth axis is moved to its stow position (typically AZIM:0.0). After moving to this indicated  
position, the RC3000 will confirm the position by looking to see if the azimuth stow switch is active. If the  
azimuth stow switch is not recognized, the mount will be moved a short distance either side of the current  
position trying to find the azimuth stow switch. If the controller fails to see the azimuth stow switch the  
following message will be displayed: “*CANNOT FIND AZ STOW SWITCH* <MODE>EXIT” and no  
further stow movements will be performed.  
- if stowing of the polarization axis is enabled, the polarization axis will next move to its defined stow  
position. As with the azimuth axis, if a polarization stow switch (if the mount is so equipped) is not  
confirmed then the message “*CANNOT FIND POL STOW SWITCH* <MODE>EXIT” will be displayed  
and no further stow movements will be performed.  
- if the azimuth and optional polarization movements complete successfully then the elevation axis will  
move to its stow position. Typically this movement ends when the elevation stow limit is encountered.  
Following completion of movement to the stow position, the RC3000 will return to MANUAL mode. The  
automatic movement may be terminated anytime by pressing the Stop key.  
Many mounts have unique stow sequence requirements. Check appendix B to see if your mount has any  
unique stow situations. Stow and deploy parameters may be customized via the Stow and Deploy  
Positions configuration screen (3.3.1.3.10). Typically the default parameters will be correct for a  
particular mount.  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.3 Locate  
The LOCATE mode performs a calculation of the pointing angle (1.3.4) to a selected satellite based on  
the RC3000’s estimate of where the antenna is positioned (lat/lon) and oriented (true heading). After the  
calculation is performed the user may initiate an automatic antenna movement to locate the selected  
satellite.  
When the mode is first entered the following screen appears.  
POS:  
SAT:GALAXY 6  
38°56N 94°44W 180.0  
74.0W  
LOCATE  
AZ:-31.1  
EL: 40.0  
<1>SELECT NEW SAT  
READY TO LOCATE  
POS: 38°56N 94°44W 180.0  
The POS: field shows the RC3000’s current estimate of antenna position. If no estimate of antenna  
position is available, the RC3000 will automatically attempt to obtain position information from the  
navigation sensors (GPS receiver and fluxgate compass) if present.  
Mount Position Initialization. In order to calculate a pointing solution, the RC3000 requires knowledge  
of the mount’s “position”. The three components of mount position are latitude, longitude and true  
heading.  
The current latitude, longitude and true heading where the RC3000 believes the antenna is positioned is  
displayed on the top line. The position data obviously affects the pointing angle that the RC3000  
calculates and is displayed as a crosscheck for the user in case the vehicle has been moved and the  
RC3000’s position has not been updated. If the lat/lon or heading data is not considered valid by the  
RC3000, asterisks will be displayed in the appropriate field and the “parameter needed” message will be  
triggered in the location readiness field.  
The RC3000 polls the GPS receiver first to get latitude and longitude information. If no communication  
with the GPS is received, the error message “GPS OFFLINE” will be displayed. In this case the interface  
between the RC3000 and the GPS receiver would need to be checked. If the RC3000 is communicating  
with the GPS receiver but the GPS indicates it has not yet been able to generate a valid lat/lon, then the  
message “NAV NOT READY” will be displayed. The “NAV NOT READY” situation should not last for  
more than a minute. If it does, then investigate whether or not the GPS receiver’s view of the sky is  
blocked by buildings, etc.  
If a valid lat/lon is received from the GPS then the lat/lon information will be displayed. Next the RC3000  
will flash “MAGVAR” while it calculates the local magnetic deviation as a function of latitude, longitude  
and time. After calculating the local magnetic variation, the RC3000 will poll the fluxgate compass for  
magnetic heading information. The magnetic variation will be applied to the magnetic heading to form the  
estimated true heading of the mount.  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
If the navigation sensors (GPS and/or compass) are not working (or not available), the position  
information may be entered manually via the POSITION mode (3.2.2.7).  
SAT: GALAXY 6 74.0W  
<1>SELECT NEW SAT  
The SAT: field shows the currently selected satellite’s name and longitude. When the mode is first  
entered the name of the last satellite selected will be displayed. If the user wishes to locate another  
satellite, he may start the process of selecting the new satellite by pressing the "1" key. See 3.2.2.3.1 for  
further details on the three methods of selecting a satellite.  
When the selected satellite is changed the LOCATE mode will automatically calculate new azimuth and  
elevation pointing targets.  
AZ: -31.1  
EL: 40.0  
These fields show the azimuth and elevation pointing angles calculated for the selected satellite based on  
the current mount position estimate. If one of the required parameters is missing or the calculation has  
yielded an invalid answer, asterisks will be displayed in these fields.  
NOTE: the displayed AZ target is not a true heading display but rather a mount-relative angle. The  
elevation target is a true elevation value.  
MAG:/TRU:  
If the user wishes to display a magnetic or true heading pointing solution (rather than antenna relative),  
he may choose how the azimuth data is presented by changing the initial_azimuth_display configuration  
item via the Azimuth Calibration (3.3.1.2.3) screen.  
Location Readiness Status  
In the lower right corner of the display, a message is displayed showing the status of the location  
calculation. Three messages may be displayed:  
1) PARAMETER NEEDED. The pointing angle calculation requires 3 sets of data a) vehicle lat/lon  
b)vehicle heading and c)satellite information. If lat/lon and/or heading is missing/invalid, the user will  
need to go to POSITION mode to enter valid data. If satellite information is missing/invalid, the user will  
need to supply that information via the mechanisms described in 3.2.2.3.1.  
2) AZIM/ELEV RANGE ERROR. If the pointing solution calculation yields an azimuth angle that is  
outside the clockwise or counter-clockwise azimuth limit (3.3.1.2.3) or outside the up or down elevation  
limit (3.3.1.2.2), one these messages will be displayed to indicate that the RC3000 does not think it can  
move the antenna to the correct position to acquire the satellite. The user may have to move the vehicle  
to place it in an orientation that will allow the mount to move to the required position. Note that this  
message may indicate that the current position data is incorrect (example: wrong heading).  
3) READY TO LOCATE / PRESS <ENTER>. This alternating message indicates that the RC3000  
considers the calculated pointing solution valid. Pressing the Enter key will initiate automatic movement  
to find the selected satellite as described in 3.2.2.3.2.  
3.2.2.3.1 Satellite Selection  
Several pieces of information must be provided to describe a satellite to the RC3000 before the satellite  
may be automatically located (and subsequently stored, recalled, tracked,etc):  
NAME: up to 10 characters (A-Z, 0-9, space)  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
LONGITUDE: described in decimal degrees (180.0W to 180.0E)  
INCLINATION: the number of degrees of orbital inclination. If a satellite is described as having an  
inclination greater than zero, the RC3000 will consider it an inclined orbit satellite and subsequently  
attempt to track its movement.  
BAND: the RF band that the user’s equipment will be receiving from the satellite. The band information  
helps determine tracking movement size and timing. Throughout the RC3000, the bands are assigned  
numbers from the following list: <0-C 1-Ku 2-CK 3-L 4-X 5-Ka 6-S>  
POLARIZATION OFFSET: predicted polarization angles (horizontal and vertical) assume that the  
spacecraft maintains its polarization axis oriented with the equatorial plane. A few satellites don't  
maintain this orientation. The amount of offset from this standard in degrees must be defined. The sign  
convention used is that the offset is defined from the perspective of looking from the earth to the satellite  
(clockwise positive, counterclockwise negative). If no offset exists, the default value of 0 is described.  
When the <1> key is selected from the main LOCATE screen, the following screen appears to allow the  
user to select new satellite information via three methods.  
1-MANUALLY ENTER SAT DATA  
2-CHOOSE SAT FROM PRESET LIST  
3-SELECT SAT LONGITUDE  
LOCATE  
<1-3>SELECT SAT DATA SOURCE <BKSP>EXIT  
manual satellite entry  
NAME:  
LON:  
LOCATE  
INCLIN:  
BAND:  
PL_OFF:  
ENTER NAME  
When the user chooses to manually enter the satellite data, a screen appears with fields to enter the four  
required pieces of data.  
Preset satellite list  
LOCATE  
# NAME  
LON INC BAND  
1 BRASIL A1 79.0W 2 C  
<SCR>THRU PRESET LIST  
<BKSP>EXIT  
When the user chooses to select a satellite from the user programmed list of satellites, a screen appears  
allowing the user to scroll through the list and select a satellite by pressing the Enter key. The preset list  
contains data for 20 satellites programmed by the user via the Preset Satellite configuration mode  
(3.3.1.1.3). It is strongly suggested that the user program and use the preset satellite list.  
Satellite Longitude  
LOCATE  
LON: 94W  
BAND:Ku  
(ASSUMES NO INCLINATION & POL OFFSET)  
<SCR>LON <7>BAND <ENTER>SELECT <0>EXIT  
When the user chooses to select a satellite longitude, a screen appears showing the satellite orbital slot  
closes to the mount's current longitude. The user may change the orbital slot by one degree at a time by  
scrolling up or down (down for more Westerly, up for more Easterly). The selected satellite's band may  
also be changed. The name used by the LOCATE function will reflect the orbital slot selected ( "94W" in  
the above example.)  
NOTE: Selected satellite data pertains only to information about a particular satellite. With respect to the  
RC3000 this is not considered “STOREd” data. See the STORE mode (3.2.2.4) for more information.  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.3.2 LOCATE Automatic Movement  
Before automatic movement to the calculated position is initiated, the RC3000 requests that a polarization  
position be selected. This is so the polarization mechanism will be in the correct position to be able to  
detect received signal strength.  
Note: this selection is not requested if the polarization configuration is defined as “circular” or if the  
polarization automove is disabled via the polarization configuration screen (3.3.1.2.4). In this case the  
RC3000 will only request that the user press the BKSP key to confirm that the automatic LOCATE  
movement is to proceed.  
H-HORIZONTAL: 85.4  
V- VERTICAL: -4.6  
8- NEUTREAL: 40.4  
LOCATE  
SAT:GALAXY 7  
<MODE>MENU  
<H/V/8> SELECT POLARIZATION <BKSP>NONE  
The RC3000 calculates the vertical polarization position as a function of mount latitude/longitude and  
satellite longitude. The horizontal position is calculated as 90 degrees from the vertical in the direction  
(Clockwise/Counter-Clockwise) that will maintain the horizontal position within the polarization axis’ range  
of movement. The “neutral” position represents the polarization angle halfway between the calculated  
vertical and horizontal values. The neutral position may be appropriate if the autopeak function is using  
the L-Band detector (RF) input for signal strength observation. If the user does not want a polarization  
movement to be performed for this LOCATE, pressing the BKSP key will initiate the elevation and  
azimuth automatic movements but a polarization movement will not be performed.  
NOTE: If the polarization calculation determines that the correct orientation is outside the polarization  
axis’ limits, the target position will be achieved by moving the position by 90 degrees. This situation is  
annotated by placing an “*” next to the calculated horizontal and vertical positions. The user may need to  
“flip” a waveguide switch in this case.  
Immediately following the polarization selection, the RC3000 will begin moving to the calculated position.  
The progress of the movement is displayed on the following screen.  
AZIM: 0.0 ( -5.9)  
ELEV: -61.7 ( 44.8)  
POL: 0.0 ( -45.0)  
LOCATE  
SAT:GALAXY 7  
MOVING TO (TARGETS) <STOP>HALT MOTION  
The current angular values for az/el/pol are displayed along with the target position for each axis in  
parenthesis. The label for the current axis being moved will flash. Movement may be halted at any time  
by pressing the Stop key. Halting movement will return the controller to the MANUAL mode.  
The first automatic movement will be in the elevation axis to ensure that the mount is brought out of the  
elevation stow and down regions. The next movement will be in the polarization axis to ready the feed  
system to detect signal strength. If enabled, tilt compensation (3.2.2.3.6) movements will be performed.  
The final movement will be in the azimuth axis. How this movement is accomplished depends on  
whether the autopeak system (see Autopeak Configuraion 3.3.1.2.6) is enabled and whether the selected  
satellite is described as having an inclined orbit or not.  
If the autopeak system is not enabled, the LOCATE mode will finish by moving to the nominal target  
azimuth position. A final movement to the target elevation will also be performed to account for change in  
mount elevation due to vehicle tilt. Following this movement, the controller will return to MANUAL mode  
where the user should peak up and confirm the identity of the satellite.  
If the autopeak system is enabled, an azimuth scanning autopeak movement (see 3.2.2.3.3) will be  
performed if the selected satellite does not have an inclined orbit. If the satellite does have an inclined  
orbit a spiral search movement (see 3.2.2.3.4) will be performed. For both autopeak movements to be  
successful, the user is required to have the receiving equipment (prior to the movement) configured for  
the RC3000 to be able to detect signal strength.  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.3.3 Azimuth Scanning Autopeak  
The figure shows the movements made to perform an azimuth scanning (SCAN) operation. This SCAN  
operation enables the RC3000 to try to compensate for any azimuth inaccuracy caused by truck heading  
calculation errors.  
1) as part of the basic LOCATE movement, the mount will be moved to the target elevation position and  
the polarization axis will be moved to the correct orientation.  
2) SCAN moves to the closest azimuth position “scan range” away from the nominal target azimuth.  
SCAN will begin trying to detect a satellite from this position.  
3) SCAN steps and samples signal strength following each step. The signal strength measurements  
are used to calculate the average background signal noise and to determine if a signal strength peak  
has been detected indicating the presence of a satellite at a particular position. The size of steps  
taken is calculated as a function of the antenna diameter and the signal band the receiving equipment  
is using to ensure that the satellite is not “stepped over”. Note that in order to compensate for any  
vehicle tilt, occasionally elevation movements are also made to stay on the target elevation. Note  
also that the stepping movements may be truncated due to the physical limit of azimuth movement.  
4) After completing the total number of step movements, SCAN moves to the position that gave the best  
indication of a satellite. If no satellite was clearly indicated, SCAN moves back to the original target.  
During the SCAN operation, line 4 of the display shows the total number of steps to be made and the  
current step being performed.  
AZIM: 0.0 ( -5.9)  
ELEV: -61.7 ( 44.8)  
POL: 0.0 ( -45.0)  
SS1:523 LOCATE  
SAT:GALAXY 7  
SCAN( 1/17) AZIMUTH FOR PEAK <STOP>HALT  
The scan range is a user-defined angular value (see autopeak configuration 3.3.1.2.6) that determines  
the range to be searched by the SCAN routine. Since this angular range is user-defineable, there are  
80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
several factors to take into consideration. If the range is too narrow, it might not be able to compensate  
for a heading error. If the range is too wide, it will take the unit slightly longer to lock up, although this is  
usually not a significant amount of time. There might also be certain situations in which two satellites will  
be at a given elevation within that specified wider range, and the RC3000 will position the antenna at the  
point of the strongest signal, even though it is not the desired satellite. This value can be changed at any  
time. It is recommended that the narrowest scan range that results in consistently locating the desired  
satellites be used.  
Following the completion of the SCAN operation, the RC3000 will move to MANUAL mode. As in the  
case of the basic LOCATE, the user should peak and confirm the identity of the satellite.  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.3.4 Spiral Search Autopeak  
The spiral search autopeak operation (SEARCH) performs somewhat differently from the SCAN  
operation. Whereas SCAN counts on the fact that a non-inclined orbit satellite should be at the  
calculated elevation, SEARCH must account for the fact that at a particular time an inclined orbit satellite  
may be above or below the nominal target elevation. The figure shows the movements made to perform  
the SEARCH operation.  
1) as part of the basic LOCATE movement, the mount will be moved to the target elevation position and  
the polarization axis will be moved to the correct orientation.  
2) SEARCH will move to the target azimuth (correcting for elevation if needed) and take an initial signal  
strength sample. Note that the target azimuth may be slightly off due to initial compass error.  
3) If no hot spot is initially found, SEARCH will begin searching an area around the target position by  
stepping in an CW/UP/CCW/DN sequence using increasing number of steps in each direction to  
effect a spiral like pattern. Unlike SCAN, SEARCH looks for a signal strength above a defined  
threshold in order to declare an end to the SEARCH operation. Performing the total search pattern  
could be time consuming so the search is terminated when a hot spot is found.  
4) If no satellite was detected, SEARCH moves back to the original target.  
During the SEARCH operation, line 4 of the display shows the current direction and step number so the  
user can keep track of the operation’s progress.  
AZIM: 0.0 ( -5.9)  
ELEV: -61.7 ( 44.8)  
POL: 0.0 ( -45.0)  
SPIRAL SEARCH(CCW 12)  
SS1:523 LOCATE  
SAT:GALAXY 7  
<STOP>HALT  
Note that when pulse-based position feedback is available, the automatic azimuth and elevation  
movements are pulse rather than pot based for greater accuracy.  
82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.3.5 Terminal Peak Up  
NOTE: this option is only functional if the mount has been fitted with high resolution pulse or  
resolver sensors for both the azimuth and elevation axes. This option will not be available on  
some mounts where the ability to fit high resolution sensors is not available. The performance of  
this movement depends on whether or not the correct azimuth and elevation pulse scale factors  
(3.3.1.3.3 and 3.3.1.3.6) have been characterized for the mount.  
The terminal peakup option is selected via the AUTOPEAK ON configuration item (3.3.1.2.6).  
If an azimuth scan finds a peak, it will return to the azimuth position where it noted the peak. This  
position may not be the absolute peak position due to the relatively large steps taken during the azimuth  
scan. If enabled, the terminal peakup option will next perform a “fine tune” peakup. While executing this  
peakup, line 4 will display “PERFORMING PEAKUP” and the AZIM and ELEV fields will display pulse or  
resolver counts rather than angles.  
During the peakup, small jogs in azimuth and elevation will be made to find the local peak position.  
These movements will be similar to the Step Track maneuver described in 3.2.2.9.1. The step sizes  
taken will approximate a theoretical signal strength change of 0.3 dB (according to antenna size,  
operating band, etc).  
3.2.2.3.6 Polarization Tilt Compensation  
If enabled via the TILT configuration item in the AUTOPEAK screen (3.3.1.2.6), additional movements in  
azimuth will be made during the LOCATE function in order to characterize the pitch and roll of the  
antenna platform.  
Rather than going directly to the beginning point for a scan operation, azimuth will be moved to points 90  
and 45 degrees away. The elevation axis will not be changed during these moves so the effect of  
platform pitch and roll can be measured via the inclinometer. During these additional azimuth  
movements a message such as "DETERMINE TILT: MOVE AZIM TO FIRST POINT" will be displayed on  
line 4 to indicate that the tilt is being characterized.  
After the platform tilt has been characterized, the normal LOCATE sequence will be finished. After  
reaching the target location, an additional step will be performed to move polarization to compensate for  
any platform tilt. During this step the message "ADJUSTING POL TO COMPENSATE FOR TILT" will be  
displayed.  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.4 Store  
The STORE mode saves a satellite’s name, azimuth and elevation positions, horizontal and vertical  
polarization positions and RF band in memory for use in later RECALLing the satellite.  
When the STORE mode is entered, it is assumed that the user has peaked up on the satellite. The first  
screen that appears asks the user to confirm the name of the satellite to be stored. The name displayed  
is that of the latest satellite “selected” in LOCATE mode.  
SAT  
BRASIL A1 79.0 2  
VERIFY SATELLITE DATA OK FOR STORING  
LON INCLIN BAND  
STORE  
C
<1>CORRECT <2>INCORRECT  
<MODE>EXIT  
If this is not the correct satellite (<2>), the following message will be displayed on lines 3 & 4 to remind  
the user to “select” the correct satellite from the LOCATE mode.  
GO TO LOCATE MODE TO SELECT SATELLITE  
<MODE> RETURN TO MENU  
If the satellite data is correct(<1>), the user will next be asked to store values for horizontal and vertical  
polarization positions. While this screen is displayed, the Pol CW and Pol CCW keys are active allowing  
the user to peak up in this axis. The “5” key is also active to initiate a 90 degree “cross polarization”  
movement. Note that the user will need to tune the receiving equipment to correct frequencies for the  
different polarizations. To store a polarization position, press the H key for horizontal and V for vertical.  
When a polarization is stored, the display for that orientation will change from “NOT SET” to SET.  
HORIZONTAL: NOT SET  
VERTICAL: NOT SET  
STORE  
POL: -4.3  
SS1:795 L  
<5>X-POL <POL CW/CCW>PEAK <H/V>STORE POL  
Note that if the signal strength source is not correct to peak up on, go to the MANUAL mode to change  
signal strength source.  
If the selected satellite is not inclined, the following screen will appear momentarily and the RC3000 will  
return to MANUAL mode.  
*** SATELLITE DATA STORED ***  
RETURNING TO MANUAL MODE  
RECALL SATELLITE VIA MENU-RECALL  
If an inclined satellite is selected (and the inclined orbit tracking option is present), control will  
automatically move to the TRACK (3.2.2.9) mode.  
If the STORE function is completed correctly, the mount’s position will saved (see POSITION 3.2.2.7). If  
the position is saved, the user will be asked to verify the position upon power up of the RC3000. If the  
mount has moved, STORED’d data will no longer be valid since the azimuth and elevation angles will no  
longer be correct.  
84  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.5 Recall  
NOTE: RECALL and DELETE modes will not be available from MENU if no satellites are currently  
“stored”.  
Satellites which have been stored in the controller's non-volatile memory (via STORE) can be recalled  
from the RECALL mode. Azimuth, elevation, and horizontal and vertical polarization data for up to 20  
satellites may be stored in non-volatile memory.  
RECALL  
STORED SATELLITE: SBS 4  
<SCR>THRU LIST <ENTER>SELECT  
Use the Scroll Up and/or Scroll Dn keys to scroll through the list of satellites stored in non-volatile  
memory. Press the ENTER key to select the desired satellite.  
If no satellites are currently stored the following screen will appear.  
RECALL  
** NO SATELLITES STORED **  
SETUP SATELLITES VIA STORE MODE  
<MODE> TO EXIT  
If invalid data was somehow stored for a satellite the following screen will appear.  
RECALL  
** INVALID DATA STORED FOR SATELLITE **  
<ENTER>SELECT ANOTHER SAT <MODE>EXIT  
After a satellite has been selected, the controller will prompt the user to specify the desired polarization  
Antenna movement to the stored position will proceed similar to the STOW and DEPLOY automatic  
movements. Antenna movement can be stopped at any time by pressing the Stop key.  
When the automatic move is completed, control will transfer to MANUAL mode if the target is a  
geostationary satellite. If the target of the automatic move is an inclined orbit satellite, TRACK mode  
receives control.  
3.2.2.6 Delete  
The DELETE mode allows a stored satellite to be removed from non-volatile memory.  
# OF STORED SATS: 12  
DELETE: AMERISTAR  
DELETE  
<SCR>THRU LIST <ENTER>DELETE <MODE>EXIT  
The user may scroll through the list of stored satellites and delete the displayed satellite by pressing the  
Enter key. Note that at the end of the list is a delete all stored satellites option. If no satellites are stored,  
the message “RETURNING TO MENU” will momentarily appear and control will return to the MENU  
mode.  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.7 Position  
The POSITION mode allows the user to set the latitude, longitude and heading of the vehicle for  
subsequent use in calculating pointing angles to satellites. The first screen that appears shows the  
current mount position used in the RC3000. Note: Mount “position” consists of the mounts latitude,  
longitude and true heading of the azimuth centerline.  
L/L:38°56N 94°44W GPS  
ANT BEARING:225.0 FLUXGATE  
<1>LAT/LON  
POSITION  
NOT SAVED  
<4>SAVE  
<2>HEADING <3>AUTO INIT  
<MODE>EXIT  
The mount’s position will not be retained at power off unless the position is explicitly saved by pressing  
the “4” key. If the position is saved, the date and time that the position was saved is noted.  
3.2.2.7.1 LAT/LON  
When the user chooses to modify latitude and longitude, a screen appears showing the current lat/lon  
and the source of that value. In the example screen the source shows that the current lat/lon was  
obtained from the GPS. If the current values had been entered manually “MANUAL” would show for the  
source. If the current values had come from the preset vehicle location list (see Preset Locations  
configuration 3.3.1.15), the name (ex. WICHITA) of the preset location would appear. If there is currently  
no valid lat/lon “NO POS SOURCE” would be displayed.  
38°56N 94°44W GPS  
LAT/LON  
SELECT LAT/LON SOURCE #  
<1>MANUAL <2>PRESET <3>GPS  
The user is prompted to select what type of source (manual entry, preset location list, gps) to use to  
modify lat/lon.  
Manual Lat/Lon Entry  
38°56N 94°44W GPS  
LAT/LON  
LAT:  
LON:  
MANUALLY ENTER LAT/LON <MODE>EXIT  
The user is provided two fields to manually enter lat and lon. See 3.1.4 (Data Entry) for instructions on  
how to enter latitude and longitude.  
Preset Location List  
38°56N 94°44W GPS  
LAT/LON  
2 37°36N 97°18W WICHITA  
<SCR>THRU LIST <ENTER>SELECT <BKSP>EXIT  
The user scrolls through the list of preset locations and selects the displayed location by pressing the  
Enter key. Note that the number within the list (2) is displayed along with the name and lat/lon.  
86  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
GPS Lat/Lon  
37°36N 97°18W WICHITA  
LAT/LON  
GPS:38°56N 94°44W 17:36:59  
<ENTER>USE GPS LAT/LON  
<BKSP>EXIT  
The current lat/lon the gps has calculated is displayed. The UTC the gps is outputting is also displayed to  
show that the data is being updated. To select this lat/lon press the Enter key. Note that if the gps is not  
reporting a valid position fix the message “WAITING FOR GPS” will appear.  
3.2.2.7.2 HEADING  
When the user chooses to modify heading, a screen appears showing the current heading (HDG:) and  
source (SRC:) of heading. If valid heading data is coming from the fluxgate, this data will appear in the  
FLUX HDG: field. The MAG VAR: field displays the calculated magnetic variation for the current  
lat/lon/date. If the RC3000 thinks it needs to recalculate magnetic variation (thinks lat/lon has changed)  
the MAG VAR: field will flash “CALC”. The magnetic variation calculation may take up to 10 seconds.  
FLUX HDG:214.3  
MAG VAR: 3.8  
HDG:180.0  
SRC:MANUAL  
HEADING  
AZ OFF: 0.0 <1>MAG <2>TRU <3>COMPASS  
TRUE HDG:218.1 SELECT SOURCE <MODE>EXIT  
To modify the heading to the value determined via the fluxgate (flux heading + azimuth offset +mag var)  
press the 3 key.  
If the user wishes to enter a magnetic heading of the vehicle press 1.  
MAG HDG=>  
HDG:180.0  
HEADING  
MAG VAR: 3.8  
SRC:MANUAL  
AZ OFF: 0.0 <1>MAG <2>TRU <3>COMPASS  
TRUE HDG: **** SELECT SOURCE <MODE>EXIT  
After the magnetic heading is entered, the RC3000 will apply the magnetic variation and azimuth offset to  
generate the true heading of the mount’s azimuth centerline.  
If the user wishes to manually enter true heading press the 1 key and the prompt to enter heading will  
appear on line 3 as shown below.  
FLUX HDG:214.3  
MAG VAR: 3.8  
AZ OFF: 0.0  
HDG:180.0  
SRC:MANUAL  
ENTER HDG=>  
HEADING  
TRUE HDG:218.1 SELECT SOURCE <MODE>EXIT  
3.2.2.7.3 INIT  
The INIT mode automatically performs the function of getting latitude/longitude from the GPS and  
heading from the fluxgate compass.  
The first stage of the INIT mode obtains latitude and longitude from the GPS.  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
INIT  
LAT/LON:*INITIALIZING GPS*  
GETTING LAT/LON FROM GPS  
The LAT/LON: field initially displays the status of communications with the GPS receiver. The following  
messages may be displayed:  
“*INITIALIZING GPS*” – The RC3000 is establishing communications with the GPS receiver.  
“*NO GPS NAV*” – Communications with the GPS is proceeding but the GPS reports has not yet  
calculated a valid navigation solution. This typically indicates one of two situations:  
1) The GPS receiver has not been powered on long enough to have “acquired” enough satellites to form  
a solution. Typically the GPS receiver will acquire the required number of satellites within several  
minutes from powerup.  
2) The GPS receiver’s view of the sky is obstructed such that it cannot “see” enough GPS satellites to  
form a solution.  
“*GPS OFFLINE*” – This message indicates that the RC3000 has not established communication with  
the GPS receiver. The cabling between the RC3000 and the GPS should be checked.  
After obtaining latitude and longitude, the INIT mode waits 10 seconds before pulling in magnetic heading  
from the compass. During this time the bottom line will flash “GETTING HEADING”. The 10 second  
delay is to ensure that the compass has settled following any previous platform movement.  
INIT  
FLUX HDG:215.2  
LAT/LON:38°56N 94°45W  
MAG VAR: 3.9  
TRUE HDG:219.1  
The INIT mode calculates magnetic variation and applies it to the magnetic heading to derive true  
heading.  
Following successful initialization of latitude, longitude and true heading the INIT mode will display a  
“POSITION INITIALIZED” message for two seconds then return to the CALCULATE mode.  
88  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.8 Settings  
The SETTINGS mode provides a way to change the operational characteristics of the RC3000 without  
having to go to the configuration group of screens. It also provides a way to reset a drive error without  
going to the DRIVE RESET maintenance screen.  
1-AUTOPEAK:OFF  
2- AP SIG:SS1  
SETTINGS  
<0>RESET DRIVE  
<MODE>MENU  
<1-2>CHANGE SETTING  
<0>RESET DRIVE  
This selection is only available if an azimuth, elevation or polarization drive error (jam or runaway) is  
active. Selecting 0 will attempt to clear the error.  
1-AUTOPEAK:  
AUTOPEAK <0>DISABLE <1>ENABLE <2>+PEAK  
Selection 0 allows the user to disable the autopeak function (OFF).  
Selection 1 allows the user to turn the basic autopeak function on (ON).  
Selection 2 allows the user to enable the terminal peakup function (ON+) described in 3.2.2.3.5. NOTE:  
Verify that the required conditions for terminal peakup as described in 3.2.2.3.5 are present before  
selecting this option.  
2-AP SIG:  
SIGNAL SOURCE <1>RF <2>SS1 <3>SS2  
Selection 2 allows the user to change the signal source that will be used with the autopeak function.  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.9 Track  
The optional TRACK mode may be entered via the STORE or RECALL modes if the selected satellite  
has been described as having a inclined orbit.  
Details of TRACK mode are available in the separate appendix TRK describing inclined orbit tracking.  
The following descriptions give an overview of how tracking is performed.  
TRACKING INCLINED ORBIT SATELLITES. The RC3000 tracking algorithm can be divided into three  
distinct stages - STEP_TRACK, MEMORY_TRACK, and SEARCH.  
AZIM: 31561  
ELEV: 11060  
POL: 8.2  
SIG:735(C)  
SAT:BRASIL A1  
STEP:PEAKING  
TRACK  
AGC  
JOGGING ANTENNA TO FIND MAXIMUM SIGNAL  
In STEP_TRACK, the controller periodically peaks on the receiver' signal strength by jogging the  
antenna. The time and position are recorded in a track table maintained in the controller’s non-volatile  
memory. The interval between peakups is determined by antenna beamwidth (determined from antenna  
size and frequency band), satellite inclination and a user specified maximum allowable error (in dB).  
When a track table entry exists for the current sidereal time, STEP_TRACK switches to  
MEMORY_TRACK.  
In MEMORY_TRACK, the controller smoothly moves the antenna to azimuth and elevation positions  
derived from entries in the track table. The time between movements is determined by the same factors  
which govern the time between peakup operations in STEP_TRACK. By increasing the maximum  
allowable error, antenna movements can be performed less frequently. In MEMORY_TRACK, the  
accuracy of the track table is monitored by periodically peaking up on the receiver’s signal strength. If the  
error exceeds a level set by the user, all entries in the track table are flagged for update.  
TRACK_SEARCH is entered when the satellite signal has been lost. The RC3000 utilizes Intelli-Search,  
an efficient search algorithm that minimizes errors associated with traditional box searches and frees the  
user from having to update vague search window parameters. This scheme accounts for the specific  
mount geometry, calculates the nominal trajectory for the satellite, and then searches in an area that  
coincides with the satellite's expected path. When the satellite is located, the controller re-enters the  
STEP_TRACK mode.  
3.2.2.10 Remote  
In REMOTE mode the controller only responds to commands received via the built-in RS-422/232 serial  
port. REMOTE mode can only become active if the Remote Mode Enable CONFIG item is enabled. If  
REMOTE mode is enabled, it can become active either in response to receipt of a valid command from  
the PC. Note that TRACK mode can process certain commands received via the serial port. The RS-422  
communication protocol, interface specification and the RC3000 command set is found in Appendix REM.  
The REMOTE mode screen is similar to the MANUAL mode screen. Only the MODE key is active when  
REMOTE mode is active.  
90  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.2.2.11 VSAT Mode  
INTRODUCTION This section details operations of the RC3000’s “VSAT” mode.  
VSAT mode is intended to be used when the following conditions exist:  
1) the mobile satellite terminal is to be run by operators with limited or no satellite communication  
training or experience  
2) the same satellite and the same polarization orientation are to be used  
3) the RC3000 is equipped with a GPS receiver and Fluxgate compass to allow automatic calculation of  
the satellite pointing solution  
VSAT mode limits the RC3000 functions that the operator may perform to LOCATE and STOW. To  
perform other functions or to change operating parameters, expert access permission must be  
established and the RC3000 must be taken out of VSAT mode.  
NOTE: VSAT “mode” refers to the overall functioning of the RC3000. VSAT is not a mode in the same  
sense as MANUAL, LOCATE, TRACK, etc. are modes.  
PRIOR TO ENTERING VSAT MODE  
VSAT mode should not be entered until the RC3000 has been well calibrated with the antenna and  
receiving systems. VSAT mode requires that the LOCATE and STOW modes consistently work well.  
In order to achieve good performance, ensure that:  
1) the azimuth, elevation and polarization axes are well calibrated  
2) the Fluxgate calibration procedure as been performed and yields good results  
3) the source of signal strength has been well calibrated  
Before entering VSAT mode, the satellite to be used and the polarization orientation (Horizontal, Vertical  
or None) has been selected as part of a completed LOCATE function.  
ENTERING VSAT MODE  
VSAT mode is selected from the SYSTEM DEFINITION configuration screen (3.3.1.2.1).  
GPS: 1  
CONFIG-SYSTEM  
WAVEGUIDE:0  
COMPASS: 1 ANT_SIZE: 120  
MODE: 2  
<1>LOCATE <2>MENU <3>MANUAL <4>VSAT  
When the value of 4 is entered for the MODE item, the RC3000 will enter VSAT “mode”.  
When VSAT mode is entered, expert access permission (3.3.1.1.1) is set to NORMAL. This in itself will  
prevent the operator from accessing most configuration items and some functions of the RC3000. VSAT  
mode will further limit operator actions as now described.  
After VSAT mode is entered, the RC3000 switches to the MENU screen. The following describes VSAT  
mode operation by showing a typical sequence of events.  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
VSAT MODE OPERATION  
After powering up the RC3000, the MENU screen will appear.  
1-LOCATE SATELLITE  
2-STOW ANTENNA  
MENU  
CST  
<1-2>SELECT <MODE>MANUAL  
14:37:23  
In VSAT mode, the MENU screen only gives the operator two automatic functions that may be performed.  
LOCATE  
Selecting <1> will put the RC3000 into LOCATE mode.  
If the antenna system has an antenna mounted compass, the following screen will prompt the operator to  
confirm that the antenna’s platform is in a safe location (not in a garage, not under power lines, etc.) for  
deployment of the antenna.  
* ANTENNA MOVEMENT REQUIRED TO LOCATE *  
* CONFIRM PLATFORM IN SAFE POSITION *  
<ENTER>BEGIN MOVEMENT  
<MODE>EXIT  
After initiating antenna movement, the antenna will be deployed and the LOCATE mode entered.  
POS:  
SAT:GALAXY 7  
39°01N 94°49W 180.1  
91.0W  
LOCATE  
AZ:-31.1  
EL: 40.0  
READY TO LOCATE  
PRESS <ENTER>  
In VSAT mode, the LOCATE screen does not allow the operator to select a satellite. The selected  
satellite (and polarization) will be the last one chosen prior to entering VSAT mode.  
When LOCATE is first entered, the mount’s position will be automatically initialized with data from the  
GPS receiver and the Fluxgate compass. There may be a delay of several minutes while the GPS  
receiver generates a navigation solution. After the GPS generates lat/lon, the local magnetic variation is  
calculated and applied to the magnetic heading from the compass to form and estimate of the true  
heading of the mount.  
The latitude, longitude and true heading will be displayed in the POS: field. The pointing solution will be  
displayed in AZ: and EL: and the messages “READY TO LOCATE” and “PRESS ENTER” will be flashed.  
When ENTER is selected (or the antenna deployment has previously been confirmed), the RC3000 will  
automatically begin positioning the antenna to locate the satellite. The previously selected polarization  
orientation (Horizontal or Vertical) will be automatically calculated.  
The autopeak function will be performed according to how it was configured (signal source, lock  
condition, scan range, etc.) prior to entering VSAT mode. Descriptions of the various operations in the  
LOCATE sequence will be displayed as the operation progresses.  
AZIM: 0.0 ( -6.1)  
ELEV: -61.7 ( 44.7)  
POL: 0.0 ( 40.3)  
LOCATE  
SAT:GALAXY 7  
MOVING TO (TARGETS) <STOP>HALT MOTION  
Following the completion of the LOCATE function, the RC3000 will display the following screen:  
92  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
!
!
LOCATE COMPLETE  
CONFIRM RECEIVER STATUS  
!
!
<MODE>MENU  
The operator should confirm that the antenna has been placed on the correct satellite. For example,  
confirmation could be achieved by recognizing if the modem has generated a signal lock.  
STOW  
By selecting <2> from MENU, the operator may initiate a STOW operation as described in 3.2.2.2. As  
with the LOCATE operation, the user will be asked to confirm that antenna movement is safe to initiate.  
MANUAL  
By selecting <MODE> from the MENU, the RC3000 may be placed in MANUAL mode.  
AZIM: -6.1( -6.1) SS1:695  
MANUAL  
ELEV: 44.6( 44.7) SAT:galaxy 7  
POL: 12.3  
SPD:SLOW  
CST  
<0-9>JOG ANTENNA <MODE>MENU  
14:25:47  
In VSAT mode the manual jog speed will be initialized to SLOW to allow fine tuning of the azimuth,  
elevation and polarization axes if required.  
EXITING VSAT MODE  
To bring the RC3000 out of VSAT mode, expert access permission must be restored to INSTALL or  
SUPER USER. Then the initial mode must be set to something other than VSAT in the SYSTEM  
DEFINITION configuration screen.  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3 Programming Group  
The programming group has two high-level modes (CONFIG-MENU and MAINTENANCE). Both of these  
modes serve as a menu system for sub-modes below them. Momentarily pressing the Mode key will  
switch between these modes in a similar fashion as the MANUAL and MENU modes switched in the  
operating group.  
3.3.1 Configuration Mode  
The CONFIG mode allows users to view and/or modify various controller parameters and to enable or  
disable certain features. Many configuration items are used to customize the RC3000 to work with a  
particular installation.  
The CONFIG mode groups configuration items into screens containing between 1 to 10 individual items.  
The top-level CONFIG-MENU allows the user to scroll through the list of configuration item groups. As  
the user scrolls through the CONFIG-MENU screens, a group title (line 1) and brief description (line 2) of  
group items is presented to identify the set of configuration items to view or modify.  
The example CONFIG-MENU screen identifies the AZIMUTH CALIBRATION group. The description “AZ  
REFERENCE VOLTAGE/LIMITS/SCALE FACTOR” provides an overview of the type of configuration  
items that will be available for viewing and/or modification.  
AZIMUTH CALIBRATION  
CONFIG-MENU  
AZ REFERENCE VOLTAGE/LIMITS/SCALE FACTOR  
<SCR>THRU LIST <ENTER>SELECT <MODE>MAINT  
To move through the CONFIG-MENU list press the Scroll Up/Yes key to advance to the next screen or  
press the Scroll Dn/No key to move to the previous screen. To select the currently identified group for  
viewing/modification press the Enter key and the screen showing the individual items in the group will  
appear. Momentarily pressing the Mode key will move from the CONFIG-MENU mode to the  
MAINTENANCE mode.  
If the AZIMUTH CALIBRATION group were selected, the following screen would appear:  
REF_V:2.50 OFF: 0.0  
CCW:180 CW:180  
CONFIG-AZIM  
SF:65.62  
SET REFERENCE VOLTAGE <2.00 – 3.00>  
In this example there are nine individual configuration items related to the azimuth axis. To move  
between the items use the Scroll Up and Scroll Dn keys. The cursor will flash at the beginning of the data  
field for the item currently selected. On line 4 a prompt briefly describing the item and showing the valid  
range of data will appear. Data may be entered for the item as described in section 3.1.4. Momentarily  
pressing the Mode key will return to the CONFIG-MENU mode.  
The following table lists all the configuration item group titles and descriptions as they appear in the  
CONFIG-MENU mode. Details for each group are provided in the following subparagraphs. The table  
also shows which configuration item groups are available according to how the expert access permission  
(3.3.1.1.1) is set.  
Additional configuration item screens may appear if they are unique to an optional feature (inclined orbit  
tracking, remote control, etc). Descriptions of those screens will be provided in their appropriate  
appendices.  
94  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
GROUP TITLE  
GROUP DESCRIPTION  
PARA.  
NORMAL ACCESS ITEMS  
EXPERT ACCESS PERMISSION  
LOCATION PRESETS  
SATELLITE PRESETS  
INSTALLATION ITEMS  
SYSTEM DEFINITON  
ELEVATION CALIBRATION  
AZIMUTH CALIBRATION  
POLARIZATION CALIBRATION  
SIG FACTORS  
SETS EXPERT ACCESS PERMISSION  
LIST OF PRESET TRUCK LOCATIONS  
LIST OF PRESET SATELLITES  
3.3.1.1.1  
3.3.1.1.2  
3.3.1.1.3  
DEFINE SYSTEM OPTIONS  
3.3.1.2.1  
3.3.1.2.2  
3.3.1.2.3  
3.3.1.2.4  
3.3.1.2.5  
3.3.1.2.6  
EL REFERENCE VOLTAGE/LIMITS/SCALE FACTOR  
AZ REFERENCE VOLTAGE/LIMITS/SCALE FACTOR  
POL REFERENCE VOLTAGE/LIMITS/SCALE FACTOR  
SIGNAL STRENGTH PARAMETERS  
AUTOPEAK  
SCAN/SEARCH PARAMETERS  
SUPER-USER ITEMS  
RESET DEFAULTS  
RESTORES PROGRAMMING TO FACTORY DEFAULTS  
AZIMUTH POT-BASED DRIVE PARAMETERS  
AZIMUTH PULSE-BASED DRIVE PARAMETERS  
AZIM ANTI-REVERSE/JAM/RUNAWAY SENSING  
ELEVATION POT-BASED DRIVE PARAMETERS  
ELEVATION PULSE-BASED DRIVE PARAMETERS  
ELEV ANTI-REVERSE/JAM/RUNAWAY SENSING  
POLARIZATION DRIVE PARAMETERS  
3.3.1.3.1  
3.3.1.3.2  
3.3.1.3.3  
3.3.1.3.4  
3.3.1.3.5  
3.3.1.3.6  
3.3.1.3.7  
3.3.1.3.8  
3.3.1.3.9  
3.3.1.3.10  
3.3.1.3.11  
AZIMUTH POT DRIVE  
AZIMUTH PULSE DRIVE  
AZIMUTH DRIVE MONITORING  
ELEVATION POT DRIVE  
ELEVATION PULSE DRIVE  
ELEVATION DRIVE MONITORING  
POLARIZATION DRIVE  
POL DRIVE MONITORING  
STOW & DEPLOY  
POL ANTI-REVERSE/JAM/RUNAWAY SENSING  
AZ/EL/POL STOW & DEPLOY POSITIONS  
SHAKE  
SETUP SHAKE MOVES/CYCLES/DELAY  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.1 NORMAL ACCESS ITEMS  
The three configuration groups contained in the “Normal” access items allow the user to change items  
that would typically be required to be changed following system configuration.  
3.3.1.1.1 Expert Access Permission  
EXPERT ACCESS:  
0
CONFIG-EXPERT  
0-NORMAL/1-INSTALL/2-SUPER<5 DIGIT CODE>  
Expert Access Permission is used to control access to installation specific items. When the  
expert_mode_active_flag is set to SUPER-USER level(2), the user has access to all controller modes  
and all CONFIG mode items. When the expert_mode_active_flag is set to INSTALL level (1), the user  
has access to all controller modes and the most typically used CONFIG mode items. When the  
expert_mode_active_flag is set to NORMAL level(0), the user is locked out of several modes and most  
CONFIG mode items. The purpose of this feature is to keep an operator away from the modes and  
CONFIG mode items which can change the contents of the controller's non-volatile memory.  
When the Expert Access screen is displayed, the present state of the expert_mode_active_flag is  
displayed in the data entry field. A display value of 2 indicates that the expert_mode_active_flag is set to  
SUPER-USER level, a value of 1 indicates that the flag is set to INSTALL level and a value of 0 indicates  
that the flag is set to NORMAL level. To toggle the state of the flag, the user must key in a 5 digit code at  
the prompt followed by the ENTER key. This code is found in a removeable Appendix A at the end of this  
manual. If the information is lost, call the factory for assistance.  
96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.1.2 Preset Locations  
This group allows the user to customize a list of 20 commonly used mount locations. This list may be  
used for selecting mount lat/lon in the POSITION mode.  
LOC#: 1  
CONFIG-LOCS  
NAME:RCI  
LAT:38°56N LON: 94°45W  
<SCR> THRU LIST, <ENTER> TO MODIFY DATA  
LOC#:  
<SCR> THRU LIST, <ENTER> TO MODIFY DATA  
This field identifies the list number (1-20) that is currently being displayed. When in this field, using the  
Scroll Up or Scroll Dn keys will move through the list.  
To modify the data press the Enter key. The cursor will move to the NAME field.  
NAME:  
ENTER <ALPHANUMERIC> LOC NAME  
This field allows a user to enter a name (up to 10 characters). See section 3.1.4 for instructions on how  
to enter alphanumeric data. After the name is entered, the cursor will move to the LAT field.  
If you do not wish to change the current name, pressing the Scroll Up key will move to the LAT field.  
Scroll Dn will move back to the LOC# field.  
LAT:  
ENTER LAT IN <DD.MM> FORMAT  
This field allows a user to enter a location’s latitude in degrees/minutes format. See section 3.1.4 for  
instructions on how to enter a latitude. After the latiitude is entered, the cursor will move to the LON field.  
If you do not wish to change the current latitude, pressing the Scroll Up key will move to the LON field.  
Scroll Dn will move back to the NAME field.  
LON:  
ENTER LON IN <DDD.MM> FORMAT  
This field allows a user to enter a location’s longitude in degrees/minutes format. See section 3.1.4 for  
instructions on how to enter a longitude. After the longitude is entered, the cursor will move to the LOC#  
field.  
If you do not wish to change the current longitude, pressing the Scroll Up key will move to the LOC# field.  
Scroll Dn will move back to the LAT field.  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.1.3 Preset Satellites  
This group allows the user to customize a list of 20 commonly used satellites. The LOCATE mode allows  
the user to select a satellite (3.2.2.3.1) from this “preset” list.  
SAT#: 3  
NAME:BRASIL A1 LON: 79.0W POFF:0.0  
INCLIN: 2 BAND:0  
CONFIG-SATS  
<SCR> THRU LIST, <ENTER> TO SELECT  
SAT#:  
<SCR> THRU LIST, <ENTER> TO MODIFY DATA  
This field identifies the list number (1-20) that is currently being displayed. When in this field, using the  
Scroll Up or Scroll Dn keys will move through the list.  
To modify the data press the Enter key. The cursor will move to the NAME field.  
NAME:  
ENTER <ALPHANUMERIC> SAT NAME  
This field allows a user to enter a name (up to 10 characters). See section 3.1.4 for instructions on how  
to enter alphanumeric data. After the name is entered, the cursor will move to the LON field.  
If you do not wish to change the current name, pressing the Scroll Up key will move to the LON field.  
Scroll Dn will move back to the SAT# field.  
LON:  
ENTER LON IN <DDD.TT> FORMAT  
This field allows a user to enter a satellite’s longitude in decimal format. See section 3.1.4 for instructions  
on how to enter satellite longitude. After the longitude is entered, the cursor will move to the INCLIN field.  
If you do not wish to change the current longitude, pressing the Scroll Up key will move to the INCLIN  
field. Scroll Dn will move back to the NAME field.  
POFF:  
POL OFFSET <-90.0 - 90.0>  
This field describes if the satellite's polarization axis is oriented non-orthogonal to the earth's equatorial  
plane. The sign convention is that described in 1.3.7.  
INCLIN:  
INCLINATION<0-12 DEG.> 0=>NON-INCLINED  
This field allows the user to define whether or not the satellite is in inclined orbit and if so the number of  
degrees the orbit is inclined.  
A number greater than zero implies that the satellite has an inclined orbit. A satellite identified as having  
an inclined orbit will enter TRACK mode following being STOREd.Entering an inclination of 0 implies that  
the satellite does not have an inclined orbit in which case the controller will not enter TRACK following  
STORE.  
BAND:  
BAND <0-C 1-Ku 2-CK 3-L 4-X 5-Ka 6-S>  
This field allows the user to specify the RF band associated with this satellite. This data is used by the  
tracking and autopeak algorithms to determine the effective bandwidth of the mount thus affecting size of  
movements made.  
NOTE: the preset list only contains data about a satellite. With respect to the RC3000 there is  
sometimes confusion between the preset list and the list of STOREd satellite data (3.2.2.4).  
STOREd data contains both satellite and mount (azimuth, elevation, polarization) position data.  
98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.2 INSTALLATION ACCESS ITEMS  
This set of configuration groups allows the user to modify parameters that are most typically changed for  
a particular installation.  
3.3.1.2.1 System Definition  
GPS: 1  
COMPASS: 1  
CONFIG-SYSTEM  
WAVEGUIDE:0  
SN:1234  
MODE: 2 ANT_SIZE: 120  
<1>GPS PRESENT <0>NOT PRESENT  
The CONFIG-SYSTEM screen allows the user to indicate the existence of optional equipment. Indicating  
that the item is not present will keep the controller from waiting for a valid response from the item in  
various modes. For example, if the GPS receiver is not present, the RC3000 will simply report “NO GPS  
PRESENT” vs. waiting for a period of time to decide that it is not receiving data from the GPS.  
GPS :  
<1>GPS PRESENT <0>NOT PRESENT  
This item specifies whether or not the optional GPS receiver is present. If specified as not present (0),  
the “NO GPS PRESENT” message will be displayed in various RC3000 screens.  
If the GPS option was not purchased, this field will always remain at 0.  
COMPASS:  
<0>NONE <1>TRUCK MOUNT <2>ANTENNA MOUNT  
This item specifies whether or not the optional fluxgate compass is present and how the compass is  
mounted if it is present. If the compass is specified as “antenna mounted”, the RC3000 will require that  
the dish be moved to the DEPLOY position to obtain magnetic heading information.  
If the compass option was not purchased, this field will always remain at 0.  
SN:  
SERIAL NUMBER<1-9999> (0=NOT ENTERED)  
The serial number of the controller may be entered in this field for easy reference later. The value of this  
field does not affect of the controller's functions.  
MODE:  
INITIAL MODE <1-LOCATE 2-MENU 3-MANUAL 4-VSAT 5-POS>  
This item specifies to which of the modes listed the RC3000 will go to upon power up.  
Selections 1, 2, 3 or 5 will direct the RC3000 to go to LOCATE, MENU, MANUAL or POSITION mode  
upon power up. For example, if the controller does not have the GPS and compass options, the user  
may want to power on to the POSITION mode.  
Selection 4 puts the controller in “VSAT” mode described in section 3.2.2.11. This section should be  
thoroughly reviewed prior to placing the controller into “VSAT” mode.  
ANT_SIZE:  
ANTENNA SIZE <1-9999 CM>  
This item specifies the size of the reflector in centimeters. For example, a 5.9 ft. diameter reflector (1.8  
m.) would require a value of 180 (cm.) be specified.  
The antenna_size_cm is used by inclined orbit tracking algorithms to characterize the antenna’s  
beamwidth thus affecting timing of various tracking movements. The value is also used by autopeak  
algorithms to determine the size of autopeak step movements.  
WAVEGUIDE: WAVEGUIDE SWITCH <1>PRESENT <0>NOT PRESENT  
This item specifies whether or not the optional waveguide switch control module is present.  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.2.2 Elevation Calibration  
REF_V:1.69 OFF: 0.0  
CONFIG-ELEV  
DOWN: 0 UP: 90.0 SF:50.00  
LOOK:1  
SET REFERENCE VOLTAGE <0.50 – 4.50>  
REF_V:  
SET REFERENCE VOLTAGE <0.50 - 4.50>  
The elev_zero_voltage defines the voltage present when the elevation axis is at its reference position .  
See the elevation zero voltage installation step.  
OFF:  
ELEVATION OFFSET <-25.0/+25.0 DEGREES>  
The elev_squint_factor configuration item corrects for discrepancies between the antenna's electrical and  
mechanical bore sight alignment. The squint factor also compensates for errors in the attachment of the  
elevation position sensor. The elevation squint factor is the difference between the antenna's theoretical  
and actual elevation pointing angle. The value for this constant is determined during the elevation  
alignment calibration procedure (2.4.2). The VALUE OF THIS CONSTANT MUST BE SET TO 0.0  
BEFORE THE ELEVATION CALIBRATION OCCURS. The nominal value of this constant is 0.0.  
DOWN:  
UP:  
SET DOWN LIMIT <0-90 DEGREES>  
SET UP LIMIT <0-90 DEGREES>  
The down_elev_limit and up_elev_limit configuration items specify the valid elevation operating range in  
degrees. If the LOCATE mode calculates a target elevation outside of this range, an elevation range  
error will be triggered.  
The spiral search algorithm (when based on pot-based movements) also uses these values to limit the  
area that may be searched.  
SF:  
SCALE FACTOR <30.00 – 60.00 mV/deg>  
The elev_scale_factor_mv_deg configuration item specifies the observed output of the elevation  
inclinometer.  
EL_LAT:  
ELEV LOOK CONFIGURATION <1>HIGH <0>LOW  
The elevation_lat_configuration item is used for mount types that have different feed boom configurations  
to achieve different elevation pointing angles. The reported elevation angle will be offset by different  
values according to whether the high or low elevation configuration is specified. Other elevation related  
items such as stow and deploy positions will also be affected. NOTE: for mounts that have only one  
feed boom configuration, this configuration item may be set to either value with no consequence.  
100  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
If the mount is equipped with resolvers, two elevation resolver calibration items are included with the  
normal inclinometer calibration items.  
REF_V:1.69 OFF: 0.0  
DOWN: 0 UP: 90.0 SF:50.00  
LOOK:1 RES: 0.0 REV:0  
CONFIG-ELEV  
SET REFERENCE VOLTAGE <0.50 – 3.50>  
RES: ELEV RESOLVER OFFSET<+/-300.00 DEGREES>  
The elev_resolver_offset configuration item defines the offset to be applied to the angle read directly from  
the elevation resolver for the purpose of displaying elevation angle. Example: If when at the elevation  
reference (deploy) position the raw elevation resolver angle reads 180.0, a elev_resolver_offset of -157.7  
will result in a resolver based elevation angle of 22.3.  
NOTE: the resolver-based angle is displayed in MANUAL mode when the elevation DOWN limit is active.  
REV: ELEV RESOLVER<0-NORMAL 1-REVERSED>  
The elev_resolver_reversed configuration item defines whether the polarity of the elevation resolver  
matches that of the RC3000 resolver circuitry. If the raw elevation resolver angle decreases as the  
mount moves up, the elev_resolver_reversed item must be described as reversed.  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.2.3 Azimuth Calibration  
REF_V:2.50 FG: 0.0  
CCW:180 CW:180  
CONFIG-AZIM  
SF:65.62  
DISP:1  
SET REFERENCE VOLTAGE <2.00 – 3.00>  
REF_V:  
SET REFERENCE VOLTAGE <1.00 - 4.00>  
The azim_zero_voltage defines the voltage present when the azimuth axis is in its center of motion. See  
the azimuth zero voltage installation section 2.3.3.  
CCW:  
CW:  
SET CCW LIMIT <0 TO 360 DEGREES>  
SET CW LIMIT <0 TO 360 DEGREES>  
These items specify the antenna's azimuth range of travel relative to the antenna’s center azimuth (0.0)  
position. These positions are used to trigger the display of the Reposition Truck message. When the  
RC3000 calculates an antenna pointing solution in LOCATE mode, it checks these values to see if the  
dish can be physically moved to that position. Thus the Reposition Truck message is displayed when the  
antenna is incapable of moving to the azimuth position required to intercept the desired satellite. These  
values are also used by autopeak algorithms to limit the area the autopeak movements will search.  
Note that these values are not used to actually limit the motion of the antenna. The antenna's azimuth  
limits are set using potentiometers inside the controller (see 2.3.1.4 - Azimuth and Polarization Electrical  
Limits). The CW Range should be set to the azimuth position which is displayed when the antenna is at  
the CW limit. In a similar manner, the CCW Range should be set to the azimuth position which  
corresponds to the controller's azimuth counter-clockwise limit. Note that the values are entered as a  
positive value, the controller will adjust the sign of the entered quantity internally.  
FG:  
FLUXGATE OFFSET <-180.0/+180.0 DEGREES>  
The azim_cal_offset item specifies the number of degrees to offset the heading reading with respect to  
the heading of the centerline of the azimuth axis. The default value for this reading is 0. A value other  
than 0 may need to be entered to correct for some mechanical misalignment in the system (see Azimuth  
and Elevation Alignment 2.5.2).  
This value will also need to be set if there is an intentional difference between the alignment of the  
compass and the centerline of azimuth movement.  
SF:  
SCALE FACTOR <1.00 – 90.00 deg/volt>  
This value specifies the azimuth scale factor applicable to the potentiometer-based azimuth feedback.  
NOTE: The default value for this item will typically be correct.  
DISP: INITIAL AZIM DISPLAY<1-ANT 3-MAG 4-TRUE>  
This value allows the user to select what format (antenna angle, magnetic heading or true heading) the  
azimuth position is initially displayed in the MANUAL and LOCATE modes. Traditionally, the antenna  
angle derived from the mount position sensor is the format displayed by the RC3000.  
102  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
In addition to the normal azimuth calibration items, two azimuth resolver calibration items are included.  
No azimuth reference_voltage or scale_factor items are displayed since no azimuth potentiometer will be  
present.  
FG: 0.0  
CCW:180 CW:180  
RES: 0.0 REV:0  
CONFIG-AZIM  
DISP:1  
SET REFERENCE VOLTAGE <2.00 – 3.00>  
RES: AZIM RESOLVER OFFSET<+/-300.00 DEGREES>  
The azim_resolver_offset configuration item defines the offset to be applied to the angle read directly  
from the azimuth resolver for the purpose of displaying azimuth angle. Example: If when at the azimuth  
stow position the raw azimuth resolver angle reads 181.3, a azim_resolver_offset of –181.3 will result in a  
resolver based azimuth angle of 0.0.  
REV: ELEV RESOLVER<0-NORMAL 1-REVERSED>  
The elev_resolver_reversed configuration item defines whether the polarity of the elevation resolver  
matches that of the RC3000 resolver circuitry. If the raw elevation resolver angle decreases as the  
mount moves up, the elev_resolver_reversed item must be described as reversed.  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.2.4 Polarization Calibration  
REF_V:2.50 OFF: 0.0  
CCW: 90.0 CW: 90.0 SF:41.67  
CONFIG-POL  
TYPE:2 REF:1 H: -45.0 V: 45.0 AUTO: 1  
SET REFERENCE VOLTAGE <2.00 – 3.00>  
REF_V:  
SET REFERENCE VOLTAGE <2.00 - 3.00>  
The pol_zero_voltage defines the voltage present when the polarization axis is in its center of motion.  
See the zero voltage installation section 2.3.4.  
OFF:  
POL OFFSET <-90.0/+90.0 DEGREES>  
The pol_offset item corrects for discrepancies between the polarization axis’ electrical and mechanical  
alignment.  
TYPE:  
<1>CIRCULAR <2>SINGLE <3>DUAL  
The polarization_type configuration item specifies the configuration of the feed drive. This item will be  
used by the controller to determine the appropriate automatic movement of the polarization axis.  
Circular type specifies that no movement will be needed to align the polarization axis.  
Single type specifies that the installation has a feed in just one orientation and therefore separate  
movements must be made to achieve horizontal and vertical polarization positions.  
Dual type specifies that separate feeds exist 90 degrees apart. For this configuration just one movement  
to achieve both horizontal and vertical positions is required. If this is not the case the system should be  
described as a single feed type so that separate movements will be made.  
SF:  
SCALE FACTOR <1.00 –180.00 deg/volt>  
This value specifies the scale factor applicable to the potentiometer-based polarization feedback. NOTE:  
The default value for this item will typically be correct.  
HOR:  
VER:  
DEFAULT HORIZONTAL POS.<-180/+180 DEG.>  
DEFAULT VERTICAL POS.<-180/+180 DEG.>  
The default_hpol_cnt and default_vpol_cnt configuration items allows the user to specify default values  
for horizontal and vertical polarization. Note that when a satellite is “stored” unique values for H and V  
may be stored.  
CW:  
CCW:  
POL CW LIMIT<0.0 - 179.9 DEGREES>  
POL CCW LIMIT<0.0 - 179.9 DEGREES>  
The cw_pol_limit and ccw_pol_limit configuration items specify the range of polarization axis movement.  
Both values are entered as positive values but the controller assigns the correct sign internally.  
The values are used to check validity of stored satellite data and for calculating horizontal and vertical  
polarization positions. Actual polarization limits are set by potentiometers as described in the installation  
section.  
AUTO:  
LOCATE AUTOMOVE <0>DISABLE <1>ENABLE  
This item lets the user specify whether or not the LOCATE mode should attempt to automatically orient  
the polarization axis  
REF: <0>HORIZONTAL <1>VERTICAL  
The orientation achieved by placing the polarization axis in the reference position.  
104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.2.5 Signal Strength Factors  
This screen defines how signal strength inputs are used. See sections 2.2.5 and 2.4.3 for references to  
the use of signal strength inputs.  
RF LOCK:0 TIME:0.1  
CONFIG-SIG  
SS1 LOCK:0 TIME:0.1 TH:100 POL:0  
SS2 LOCK:0 TIME:0.1 TH:100 POL:0  
<0>NEGATIVE <1>POSITIVE AGC INPUT SENSE  
RF LOCK:  
<0-NONE 1-1HI 2-1LO 3-2HI 4-2LO>  
When the autopeak source is the RF input, this item defines whether a discrete signal lock input is  
required to indicate a satellite has been found. The signal lock input may help in distinguishing the  
correct satellite while doing a LOCATE.  
If a signal lock input is used, it may be defined as either having a HI (>3.5 VDC) or LO (< 0.8 VDC) level  
that indicates lock.  
SS1 LOCK:  
SS2 LOCK:  
LOCK TYPE <0>NONE <1>HI <2>LO  
LOCK TYPE <0>NONE <1>HI <2>LO  
When the autopeak source is the SS1 or SS2 input, these items define whether a discrete signal lock  
input is required to indicate a satellite has been found. The signal lock input may help in distinguishing  
the correct satellite while doing a LOCATE.  
If a signal lock input is used, it may be defined as either having a HI (>3.5 VDC) or LO (< 0.8 VDC) level  
that indicates lock.  
RF TIME:  
SS1 TIME:  
SS2 TIME:  
RF DELAY TIME <0.1 – 9.9> SECONDS  
SS1 DELAY TIME <0.1 – 9.9> SECONDS  
SS1 DELAY TIME <0.1 – 9.9> SECONDS  
These items define how long the RC3000 will wait after each step before sampling signal strength.  
Increasing this value may be required to allow equipment such as a modem to generate an AGC output.  
NOTE: if a RF_LOCK value of 0 (no signal lock conditioning) is selected, the RF_TIME item is ignored  
and a smooth (non-stepping) scan will be implemented.  
SS1 POL:  
SS2 POL:  
<0>NEGATIVE <1>POSITIVE INPUT SENSE  
<0>NEGATIVE <1>POSITIVE INPUT SENSE  
The SS1/SS2 polarity flags tell the controller what the sense is on the signal strength input voltage used  
for tracking and autopeak operations. A positive sense is defined as one that increases in magnitude as  
the RF signal strength increases. If the signal strength voltage decreases as the RF signal increases, its  
polarity is considered negative.  
SS1 TH:  
SS2 TH:  
SS1 MINIMUM SIGNAL THRESHOLD <0-999>  
SS2 MINIMUM SIGNAL THRESHOLD <0-999>  
These threshold items define what the minimum signal strength indication for each channel is required for  
the tracking system to “recognize” that a satellite is present. NOTE: these items are only applicable to  
TRACK mode.  
If different bands are received that exhibit different “off satellite” signal strengths, the highest “off satellite”  
value should be used to avoid the possibility of recognizing noise as a satellite.  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.2.6 Autopeak  
This screen defines how the autopeak functions of the LOCATE mode are configured.  
ON:1 SRCH_AZ: 3 CONFIG-AUTOPEAK  
SIG:1 SRCH_EL: 3 SCAN_RG: 2  
BAND:1 SRCH_TH:200 SCAN_TH:200 TILT:0  
AUTOPEAK <0>DISABLED <1>ENABLED <2>+PEAK  
ON:  
AUTOPEAK <0>DISABLED <1>ENABLED <2>+PEAK  
The autopeak_enabled item defines if autopeak (SCAN or SEARCH) movements are to be performed as  
part of the LOCATE movement.  
If disabled (selection 0), the LOCATE procedure will move to the nominal target position without  
attempting an autopeak procedure.  
If enabled (selection 1), the Azimuth Scanning (3.2.2.3.3) or Spiral Search (3.2.2.3.4) Autopeak  
movement will be attempted.  
If selection 2 (+PEAK) is chosen, the terminal peakup movement described in 3.2.2.3.5 will also be  
enabled. NOTE: Verify that the required conditions for terminal peakup (3.2.2.3.5) are present  
before selecting this option.  
SIG:  
SIGNAL SOURCE <1>RF <2>SS1 <3>SS2  
The autopeak_signal_source item defines which of the three signal source channels will be used to  
recognize if a satellite is present.  
BAND:  
BAND <0-C 1-Ku 2-CK 3-L 4-X 5-Ka 6-S>  
The autopeak_band item defines what RF band the receiving equipment is set for during an autopeak.  
The band used will affect the size of steps used for autopeak movements.  
SRCH_AZ:  
SRCH_EL:  
SPIRAL SEARCH AZIM LIMIT <1-15 DEGREES>  
SPIRAL SEARCH ELEV LIMIT <1-15 DEGREES>  
The search_azim/elev_limit items define the area that the spiral search pattern is allowed to search to  
recognize a satellite. If a satellite is not recognized after searching the area defined by these limits, the  
spiral search will return to the nominal target position. The larger the limits, the longer time a search  
might take. If the limits are too small to account for azimuth target inaccuracy due to heading error or to  
account for the amount of elevation movement an inclined orbit satellite may exhibit, the spiral search  
may quit before moving over the satellite.  
SRCH_TH:  
SPIRAL SEARCH THRESHOLD <0-999>  
This threshold item defines what the minimum signal strength indication is required for the search  
procedure to recognize that a satellite is present.  
SCAN_RG:  
SCAN RANGE <1-15 DEGREES>  
The scan_range item defines how many degrees to either side of the nominal azimuth target the scan  
autopeak operation will search.  
TILT:  
POL TILT COMPENSATION <0>OFF <1>ON  
This item specifies if additional movements are to be made during the LOCATE function in order to  
characterize the pitch and roll of the platform. Refer to section 3.2.2.3.6 for discussion of this feature.  
106  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
SCAN_TH:  
SCAN THRESHOLD <0-999>  
This threshold item defines what the minimum signal strength indication is required for the scan  
procedure to recognize that a satellite is present.  
The definition of this value is different depending on whether the L-Band power detector (RF) or one of  
the two signal strength (SS1 or SS2) channels is used for the autopeak signal source.  
When using SS1 or SS2 as the autopeak signal source, the threshold value refers to the absolute value  
above which the scan procedure should recognize that a satellite is present. Per the signal strength  
adjustment calibration procedure (2.4.3.2), SS1 or SS2 channels should be tuned such that a value of  
approximately 50 is displayed when the antenna is completely off of a satellite (open sky) and a value of  
approximately 650 is displayed when the antenna is peaked up on a satellite. When using SS1 or SS2, a  
threshold value of 200 would typically be appropriate.  
When using the RF (L-Band power) as the autopeak signal source, the threshold value refers to the  
amount of displayed value above the average noise floor reading that indicates the antenna is passing  
across a satellite. Note that the RF input is a logarithmic indication of total power across the L-Band  
(950-2150 MHz) range. Typically a value of 400 will be displayed when looking at the open sky. Also  
typically a value of 700 may be displayed when the antenna is looking at satellite with multiple  
transponders active. These values will vary according to the amount of attenuation in the system,  
satellite power, etc. When using RF, a threshold value of 100 would typically be appropriate.  
When using either type of input as the autopeak signal source, the characteristics of the displayed value  
should be observed as the scan procedure moves across a satellite. If the threshold value is too low, the  
scan procedure may incorrectly recognize a random spike in the noise floor as an indication of a satellite.  
Conversely, if the threshold value is too high, the scan procedure may not recognize the presence of a  
satellite.  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3 Super-User Access Items  
This set of configuration groups allows the user to modify parameters that are not typically changed for a  
particular installation. Usually these items address parameters that have been previously characterized  
for a particular mount. The need to access these items would typically only occur if a unique  
customization of the system was required.  
3.3.1.3.1 Reset Defaults  
RESET CODE:  
0
CONFIG-DEFAULTS  
0-NORMAL/1-INSTALL/2-SUPER<5 DIGIT CODE>  
The CONFIG-DEFAULTS screen is used to reset the controller's non-volatile memory. When this occurs,  
the various CONFIG mode items are initialized to a default value. This operation is usually performed at  
the factory. Access to this item is allowed only when the Expert Access flag is set. To reset the system  
memory, the user must key in the same 5 digit code used for Expert Access, followed by the ENTER key.  
Sections 3.3.1.1, 3.3.1.2 and 3.3.1.3 explain the items covered by the three levels of access: normal,  
installation and super-user.  
NOTE: the two expert access codes are contained in appendix A. This appendix may have been  
removed by a system manager to limit use of the codes.  
Besides restoring configuration items to their factory default values, stored satellite data including inclined  
orbit tracking tables will be cleared.  
Appendix B provides tables of factory defaults for each mount type supported. It is strongly suggested  
that the appropriate table be used to record installation specific data should this data somehow become  
corrupted in the controller.  
108  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.2 Azimuth Pot Drive  
The CONFIG-AZ POT screen contains configuration items for calibrating large automatic azimuth  
movements based on angle (potentiometer or resolver-based) position feedback. See the Drive System  
theory section 1.3.7.  
CONFIG-AZ POT  
FAST/SLOW: 0.5  
MAX ERROR: 0.01  
COAST: 0.0  
TRIES: 3  
SET ZERO VOLTAGE <2.00 - 3.00>  
FAST/SLOW:  
SET THRESHOLD <0.0-10.0 DEGREES>  
During an automatic move, the azim_fast_slow_threshold configuration item is used to set the number of  
degrees before a target position is reached, when the controller switches the speed of the drive from fast  
to slow.  
MAX ERROR:  
SET MAXIMUM ERROR <0.01 - 1.00 DEGREES>  
The azim_max_position_error configuration item sets the maximum acceptable error between the final  
resting position and a target position during an automatic move.  
COAST:  
SET COAST RANGE <0.0 - 2.0 DEGREES>  
During an automatic move, the azim_coast_threshold configuration item sets the number of degrees  
before the target position is reached where the drive will be deactivated. The idea is to deactivate the  
drive and let the antenna coast into position. If prior to the initiation of the move operation, the total  
number of degrees that the actuator has to move to reach the target position is less than the 'Coast  
Threshold, the drive will be deactivated when its position is within 'Max Position Error of the target  
position.  
TRIES:  
SET MAX NUMBER OF TRIES <0-10>  
The azim_auto_move_max_retry_cnt configuration item sets the maximum number of attempts which will  
be made to hit a target position (within Max Error - described above) during an automatic move based  
on angle feedback.  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.3 Azimuth Pulse Drive  
The CONFIG-AZ PULSE screen contains items for configuring automatic movements based on sensor  
count (resolver or pulse) azimuth position feedback.  
SCALE:2406  
CONFIG_AZ PULSE  
CW:49451 FAST/SLOW: 50 COAST: 5  
CCW:16085 MAX ERROR: 3 TRIES: 3  
AZIM SCALE FACTOR<1-32767 PULSES/RADIAN>  
SCALE:  
AZIM SCALE FACTOR <1-32767 PULSES/RADIAN >  
The antenna_azim_constant configuration item specifies the approximate number of pulses measured  
per radian of azimuth travel. See installation section 2.4.4 for calculation of the azimuth pulse scale  
factor.  
The antenna_azim_constant is used by inclined orbit tracking and autopeak algorithms for determining  
movement amount (in pulses).  
CW:  
CCW:  
AZIM CW PULSE LIMIT <0 - 65535>  
AZIM CCW PULSE LIMIT <0 - 32768>  
The cw_azim_pulse_limit and ccw_azim_pulse_limit configuration items specify the range of azimuth  
motion measured in pulses. These items are used by the tracking and autopeak algorithms to place  
bounds on the area searched. These values are also used to determine the validity of stored satellite  
data.  
FAST/SLOW:  
SET THRESHOLD <0 - 999 PULSES>  
During an automatic move, the azim_fast_slow_pulse_threshold configuration item is used to set the  
number of pulses before a target position is reached, when the controller switches the speed of the drive  
from fast to slow.  
MAX ERROR:  
SET MAXIMUM ERROR <0 - 10 PULSES>  
The azim_max_position_pulse_error configuration item sets the maximum acceptable error between the  
final resting position and a target position during an automatic move.  
COAST:  
SET COAST RANGE <0 - 999 PULSES>  
During an automatic move, the azim_coast_pulse_threshold configuration item sets the number of pulses  
before the target position is reached where the drive will be deactivated. The idea is to deactivate the  
drive and let the antenna coast into position. If prior to the initiation of the move operation, the total  
number of degrees that the actuator has to move to reach the target position is less than the 'Coast  
Threshold, the drive will be deactivated when its position is within 'Max Error of the target position.  
TRIES:  
SET MAX NUMBER OF TRIES <0-10>  
The azim_auto_move_max_retry_pulse_cnt configuration item sets the maximum number of attempts  
which will be made to hit a target position (within Max Error - described above) during an automatic  
move based on potentiometer feedback.  
110  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.4 Azimuth Drive Monitoring  
The items on this screen deal with the background checking performed on the azimuth drive system.  
Note that in this context “slop” may be typically considered relating to mechanical hysteresis.  
CONFIG-AZ MON  
JAM SLOP:  
RUN SLOP: 50  
1
FAST DEADBAND: 1000  
SLOW DEADBAND: 500  
SET JAM SLOP <0 - 1023>  
JAM SLOP:  
SET JAM SLOP <0 - 1023>  
The azim_jam_pot_slop item specifies the amount of sensed movement the controller wants to see  
before declaring a jam condition. See the Drive System theory section.  
The entered value is in units of the resolution the RC3000’s analog to digital conversion system. This  
resolution will depend on a particular mount’s range of movement, etc. See appendix B for details for a  
particular mount.  
The value should be set to avoid nuisance jams but allow a jam to be declared within a reasonable  
amount of time to avoid damage to the system. Too high of a value will trigger false jam conditions since  
the mount may sometimes not be able to move that far in the required interval. Too low of a value may  
allow mechanical slop in the system to appear as valid movement thus never triggering a jam.  
Setting the value to 0 will disable the jam sensing since no movement will be required to be sensed to  
make the jam system think the mount has moved when it should. This may be a useful thing to do in  
emergency situations to alleviate unwanted jam declarations but should only be done temporarily vs.  
having an active jam sensing system.  
RUN SLOP:  
SET RUNAWAY SLOP <0-1023>  
The azim_runaway_pot_slop item specifies the amount of movement that may be sensed before a  
runaway condition is declared when the antenna is not supposed to be moving.  
The entered value is in units of the resolution the RC3000’s analog to digital conversion system. This  
resolution will depend on a particular mount’s range of movement, etc. See appendix B for details for a  
particular mount. If the installation has pulse-based sensing this value will indicate the number of pulses  
the system may see before declaring a runaway.  
If the entered value is too low, normal noise from the potentiometer or slight movement due to wind may  
trigger a runaway. If the value is too high, it may take a long time to generate a runaway. To essentially  
disable runaway sensing, set the value to 1023.  
FAST DEADBAND:  
SLOW DEADBAND:  
SET FAST DEADBAND <0 - 9999 MSEC>  
SET SLOW DEADBAND <0 - 9999 MSEC>  
The azim_fast_deadband_msec and azim_slow_deadband_msec items are used for the anti-reversal  
system. To understand the purpose of these parameters, it is necessary to consider how position counts  
are accumulated. The feedback from the azimuth and elevation position sensors is pulses. When a  
pulse is received, the controller checks to see which way the antenna was last commanded to move. If  
the antenna is moving, or last moved, east (down), the azimuth (elevation) position count is decremented.  
If the antenna is moving, or last moved, west (up) the azimuth (elevation) position count is incremented.  
In MANUAL mode, the user can jog the antenna. If the UP arrow key is depressed, the antenna will  
move up. If the user suddenly depresses the DOWN arrow key and the antenna drive signals were  
instantaneously reversed, the antenna continues to move up for some small period of time, then the  
antenna reverses direction and starts to move down. This can cause position count errors. When the  
antenna drive signals are configured for down movement but the antenna is still moving up, pulses which  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
are received would cause the elevation position count to decrement when the count should really be  
incremented because the antenna is really still moving up.  
The anti-reversal system keeps the antenna from rapidly changing direction. If the antenna has been  
moving in a given direction, the 'Deadband CONFIG mode items specify the amount of time that the  
system will wait before asserting the antenna drive lines to move the antenna in the opposite direction.  
There are 2 different 'Deadband values specified - there are unique fast and slow speed values. If the  
antenna has been moving fast, the 'Fast Deadband parameters specify the wait interval; if the antenna  
has been moving slow, the 'Slow Deadband parameters specify the wait interval. Both 'Deadband values  
are given in milliseconds.  
112  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.5 Elevation Pot Drive  
CONFIG-EL POT  
FAST/SLOW: 0.5  
MAX ERROR: 0.01  
COAST: 0.3  
TRIES: 3  
SET THRESHOLD <0.0-10.0 DEGREES>  
The CONFIG_EL POT screen contains configuration items for calibrating elevation movements based on  
potentiometer position feedback. See the Drive System theory section 1.3.7.  
FAST/SLOW:  
SET THRESHOLD <0.0-10.0 DEGREES>  
During an automatic move, the elev_fast_slow_threshold configuration item is used to set the number of  
degrees before a target position is reached, when the controller switches the speed of the drive from fast  
to slow.  
MAX ERROR:  
SET MAXIMUM ERROR <0.01 - 1.00 DEGREES>  
The elev_max_position_error configuration item sets the maximum acceptable error between the final  
resting position and a target position during an automatic move.  
COAST:  
SET COAST RANGE <0.0 - 2.0 DEGREES>  
During an automatic move, the elev_coast_threshold configuration item sets the number of degrees  
before the target position is reached where the drive will be deactivated. The idea is to deactivate the  
drive and let the antenna coast into position. If prior to the initiation of the move operation, the total  
number of degrees that the actuator has to move to reach the target position is less than the 'Coast  
Threshold, the drive will be deactivated when its position is within 'Max Position Error of the target  
position.  
RETRY:  
SET MAX NUMBER OF TRIES <0-10>  
The elev_auto_move_max_retry_cnt configuration item sets the maximum number of attempts which will  
be made to hit a target position (within Max Error - described above) during an automatic move based  
on potentiometer feedback.  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.6 Elevation Pulse Drive  
SCALE:2406  
CONFIG_EL PULSE  
CW:49451 FAST/SLOW: 50 COAST: 5  
CCW:16085 MAX ERROR: 3 RETRY: 3  
ELEV SCALE FACTOR<1-32767 PULSES/RADIAN>  
SCALE:  
ELEV SCALE FACTOR<1-32767 PULSES/RADIAN >  
The antenna_elev_constant configuration item specifies the approximate number of pulses measured per  
radian of elevation travel. See the installation section for calculation of the elevation pulse scale factor.  
The antenna_elev_constant is used by inclined orbit tracking and autopeak algorithms for determining  
amount movement (in pulses).  
UP:  
ELEV UP PULSE LIMIT <100 - 65535>  
DOWN:  
ELEV DOWN PULSE LIMIT <100 - 65535>  
The ip_elev_pulse_limit and down_elev_pulse_limit configuration items specify the range of elevation  
motion measured in pulses. These items are used by the tracking and autopeak algorithms to place  
bounds on the area searched. These values are also used to determine the validity of stored satellite  
data.  
FAST/SLOW:  
SET THRESHOLD <0 - 999 PULSES>  
During an automatic move, the elev_fast_slow_pulse_threshold configuration item is used to set the  
number of pulses before a target position is reached, when the controller switches the speed of the drive  
from fast to slow.  
MAX ERROR:  
SET MAXIMUM ERROR <0 - 10 PULSES>  
The elev_max_position_pulse_error configuration item sets the maximum acceptable error between the  
final resting position and a target position during an automatic move.  
COAST:  
SET COAST RANGE <0 - 999 PULSES>  
During an automatic move, the elev_coast_pulse_threshold configuration item sets the number of pulses  
before the target position is reached where the drive will be deactivated. The idea is to deactivate the  
drive and let the antenna coast into position. If prior to the initiation of the move operation, the total  
number of degrees that the actuator has to move to reach the target position is less than the 'Coast  
Threshold, the drive will be deactivated when its position is within 'Max Error of the target position.  
TRIES:  
SET MAX NUMBER OF TRIES <0-10>  
The elev_auto_move_max_retry_pulse_cnt configuration item sets the maximum number of attempts  
which will be made to hit a target position (within Max Error - described above) during an automatic  
move based on potentiometer feedback.  
3.3.1.3.7 Elevation Drive Monitoring  
This group performs the same functions for the elevation axis as described in 3.3.1.8 (Azimuth Drive  
Monitoring)  
114  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.8 Polarization Drive  
The CONFIG-POL DRV screen contains configuration items for calibrating polarization movements based  
on potentiometer position feedback. See the Drive System theory section 1.3.7.  
CONFIG-POL DRV  
FAST/SLOW: 2.0  
MAX ERROR: 0.10  
COAST: 0.3  
TRIES: 3  
SET THRESHOLD <0.0-10.0 DEGREES>  
FAST/SLOW:  
SET THRESHOLD <0.0-10.0 DEGREES>  
During an automatic move, the pol_fast_slow_threshold configuration item is used to set the number of  
degrees before a target position is reached, when the controller switches the speed of the drive from fast  
to slow.  
MAX ERROR:  
SET MAXIMUM ERROR <0.01 - 1.00 DEGREES>  
The pol_max_position_error configuration item sets the maximum acceptable error between the final  
resting position and a target position during an automatic move.  
COAST:  
SET COAST RANGE <0.0 - 2.0 DEGREES>  
During an automatic move, the pol_coast_threshold configuration item sets the number of degrees before  
the target position is reached where the drive will be deactivated. The idea is to deactivate the drive and  
let the antenna coast into position. If prior to the initiation of the move operation, the total number of  
degrees that the actuator has to move to reach the target position is less than the 'Coast Threshold, the  
drive will be deactivated when its position is within 'Max Position Error of the target position.  
RETRY:  
SET MAX NUMBER OF TRIES <0-10>  
The pol_auto_move_max_retry_cnt configuration item sets the maximum number of attempts which will  
be made to hit a target position (within Max Error - described above) during an automatic move based  
on potentiometer feedback.  
3.3.1.3.9 Pol Drive Monitoring  
This group performs the same functions for the polarization axis as described in 3.3.1.8 (Azimuth Drive  
Monitoring)  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.10 Stow & Deploy Positions  
The STOW & DEPLOY group allows the user to change the target positions for STOW and DEPLOY  
movements.  
AZ_STW: 0.0 AZ_DEP: 0.0 CONFIG-STOW  
EL_STW: -67.5 EL DEP: 22.3 EL_TIME: 0  
PL STW: 0.0 PL_DEP: 0.0 PL_ENABLE:0  
AZIMUTH STOW <-180.0/180.0>  
AZ_STW:  
EL_STW:  
PL_STW:  
AZIMUTH STOW <-180.0/180.0>  
ELEVATION STOW <-90.0/90.0>  
POL STOW <-180.0/180.>  
These items define the STOW position.  
AZ_DEP:  
EL_DEP:  
PL_DEP:  
AZIMUTH DEPLOY<-180.0/180.0>  
ELEVATION DEPLOY <-90.0/90.0>  
POL DEPLOY <-180.0/180.0>  
These items define the DEPLOY position.  
PL_ENABLE:  
POL MOVE <0-NONE 1-STOW 2-DEPLOY 3-BOTH>  
This item defines whether or not the polarization axis is moved during a STOW and/or DEPLOY.  
0 – the polarization axis will not be moved as part of either STOW or DEPLOY  
1 – polarization will move to the PL STW position as part of STOW (no DEPLOY movement)  
2 – polarization will move to the PL DEP position as part of DEPLOY (no STOW movement)  
3 – polarization will move during both STOW and DEPLOY  
NOTE: the default value is to have polarization move during DEPLOY to be consistent with earlier  
versions of the software. Default STOW movement is per mount.  
EL_TIME:  
ELEV STOW TIMER<0-DISABLE, 1-99 SECONDS>  
On certain mounts there needs to be a delay between the time that the elevation stow limit is sensed and  
when the elevation motor is deenergized. For mounts where this is not the case, this item is ignored.  
116  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.1.3.11 SHAKE  
AZ 1: -40.0 2: 50.0 3: 0.0 CONF-SHAKE  
EL 1: 30.0 2: 40.0 3: -67.5 CYCLE: 100  
PL 1: -10.0 2: 10.0 3: 0.0 DELAY: 15  
MOVE 1 AZIM <-180.0/180.0>  
AZ #:  
MOVE # AZIM <-180.0/180.0>  
The AZ field allows the user to specify the azimuth target for moves 1, 2 or 3.  
EL #: MOVE # ELEV <-90.0/90.0>  
The EL field allows the user to specify the elevation target for moves 1, 2 or 3.  
PL #: MOVE # POL <-180.0/180.0>  
The PL field allows the user to specify the polarization target for moves 1, 2 or 3.  
CYCLE: NUMBER OF SHAKE CYCLES <1-9999>  
The CYCLE field allows the user to specify the total number of movement cycles the SHAKE function will  
perform.  
DELAY:  
DELAY <0-999 SECONDS>  
The DELAY field allows the user to specify the amount of time (in seconds) that the SHAKE function will  
wait between “moves”. Specifying a value of 0 will cause no delay between “moves”.  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2 Maintenance Items  
1-VOLTS 2-DRIVE 3-TIME 4-SIG MAINT  
5-LIMITS 6-GPS COM 7-FG COM 8-MOVETO  
9-FG CAL 0-SHAKE  
.-CI RECORD  
Z1-GTRv1.55  
This screen provides a menu system for selecting the various maintenance screens described in the  
following paragraphs. Pressing the Mode key from this screen will return the controller to the CONFIG-  
MENU screen. The software options and version are displayed in the lower right corner.  
Note that if expert access is not enabled, selections 9 (fluxgate calibration) and 0 (shake) are not made  
available.  
118  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.1 Analog to Digital Voltage  
The AD VOLTAGES maintenance screen shows the current voltage levels sensed at the microcontroller’s  
4 analog to digital inputs. The voltage will be displayed in the 0.001 to 5.000 range. If the microcontroller  
sees less than 0.001, it will display “UNDER”.  
Note that all of the analog to digital channels have some associated scaling and conditioning circuitry in  
the RC3000. Therefore the voltages seen at this screen will not be exactly the same as the input  
voltages external to the RC3000.  
AZ: 1.114  
EL: 1.143 1  
POL: UNDER  
AD VOLTAGES  
L1:1  
L2:0  
SIG: 3.756(1) <1>RF <2>SS1 <3>SS2 <4>AUX  
AZ: / EL: / POL:  
The first three A/D channels are dedicated to the azimuth, elevation and polarization position sensing  
inputs.  
Next to the elevation voltage is displayed a 0 or 1. 0 means the elevation sensor circuit is currently  
operating in the “low” region while 1 indicates it is operating in the “high” region.  
SIG:  
The fourth channel (signal strength) is multiplexed between four sources (autopeak RF, signal strengths  
1 and 2 and an auxiliary input). Pressing keys 1-4 allow selecting of one of the signal source inputs for  
display.  
On first generation controllers, the signal source # 4 is tied to ground and should indicate a value close to  
0.000 (maybe UNDER). On second generation controllers, this input may be used for other signals (see  
your appendix B).  
L1: / L2:  
These fields show the status of the signal lock 1 and 2 inputs. A logic high signal is indicated by a “1”.  
RESOLVER DATA  
If a particular mount implements resolver sensors, this screen will also shows “raw resolver” angles and  
counts.  
AZ: 1.114 181.30 33004  
AD VOLTAGES  
EL: 1.143 1 122.30 22264 22.3  
POL:2.237 181.30 33044  
L1:1  
L2:0  
SIG: 3.756(1) <1>RF <2>SS1 <3>SS2 <4>GND  
The azimuth, elevation and polarization resolver angles and counts displayed are read directly from the  
resolvers without being biased by offset terms. The displayed values will though reflect if the azimuth,  
elevation or polarization resolver polarity has been reversed.  
As an aid in calibrating the elevation resolver, the angle resulting from applying offset a reverse factors is  
also displayed on the EL: line.  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.2 Drive Error Resets  
1-AZIM: JAMMED  
DRIVE RESET  
2-ELEV: RUNAWAY  
3- POL: OK  
4-RESET PULSE COUNT  
(AZ/EL AT STOW)  
RESET <1-3>AXIS <4>PULSES  
<MODE>EXIT  
The DRIVE RESET maintenance screen provides the way to reset drive system errors (JAMMED /  
RUNAWAY / DRIVE) for each axis. See the drive system theory section (1.3.7) for description of these  
conditions. An axis’ drive status may be reset by pressing the corresponding key.  
These screen also provides for resetting the azimuth and elevation pulse counts to their reset state of  
32768 (middle of azimuth range) and 100 (bottom of elevation range).  
3.3.2.3 Time Maintenance  
The Time Maintenance screen allows the user to set the system and reference (see section 1.3.11) time.  
Note that all dates are displayed and entered in day/month/year (DD/MM/YY) format. All times are  
displayed and entered in hour/minute/second (HH:MM:SS) format. Refer to section 3.1.4 for instructions  
on entering date and time.  
SYSTEM:11/10/97 22:26:40  
GPS UTC:*GPS OFFLINE*  
TIME  
ZONE:CST  
DISPLAY:11/10/97 16:26:40  
OFFSET:- 6  
1-DATE 2-TIME 3-SYNCH 4-ZONE 5-OFFSET  
SYSTEM:DD/MM/YY HH:MM:SS  
Current date and time as maintained by the RC3000’s real-time clock.  
GPS UTC:  
Universal Coordinated Time (UTC) from the GPS if valid time data is being received. If valid time data is  
not being received, a GPS status message is displayed:  
*GPS OFFLINE* - no serial data from GPS is being received  
*WAITING FOR GPS* - serial data is being received from GPS but data indicates an accurate time  
solution cannot be guaranteed  
*NO GPS PRESENT* - The GPS present configuration item has been set to indicate that a GPS receiver  
is not installed.  
DISPLAY:  
Current “reference” time that will be displayed in several screens (MANUAL, MENU). This time is offset  
from the system time by the OFFSET number of hours described later.  
ZONE:  
A three character alphanumeric timezone string the user may customize for displaying during the  
MANUAL and MENU modes. This string may be changed by selecting action 4 (ZONE).  
OFFSET:  
The number of hours the displayed reference time is offset from system time.  
120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
The values for the time parameters may be altered by the actions described next.  
1-DATE ENTER DATE DD.MM.YY  
Chapter 3  
Detailed Operation  
This action allows the user to manually set the date. The prompt indicates that the / delimiter for date is  
entered by using the (decimal point) key.  
2-TIME  
ENTER TIME HH.MM.SS  
This action allows the user to manually set the system time. The prompt indicates that the : delimiter for  
time is entered by using the (decimal point) key.  
3-SYNCH  
If valid GPS UTC data is being received, pressing the 3 key will cause system time to be synchronized  
with the current GPS UTC.  
4-ZONE  
The user may enter three alphanumeric characters (ex. CST) for a timezone designator.  
5-OFFSET ENTER TIMEZONE OFFSET <-11/+12 HOURS>  
ENTER 3 LETTER TIME ZONE  
The user may enter the number of hours of offset from system time for offsetting displayed time.  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.4 Signal Strength Offset Calculator  
The signal strength offset calculator determines parameters needed to perform the signal strength  
channel calibration (2.3.5.2) procedure. The user enters observed voltages from receiving equipment  
and the required offset for both of the RC3000’s signal strength channels is calculated.  
POLARITY:NEG SIG_OFFSET  
ON_SAT: -3.223 SS1_OFF: -0.0655  
OFF_SAT: 7.651 SS2_OFF: -0.5447 *  
NOTE POLARITY & OFFSETS  
<MODE>EXIT  
ON_SAT:  
Enter the voltage coming from the receiving equipment when “on satellite”.  
OFF_SAT: ENTER OFF SATELLITE VOLTS<-15.00/15.00>  
Enter the voltage coming from the receiving equipment when “off satellite”.  
NOTE POLARITY & OFFSETS <MODE>EXIT  
ENTER ON SATELLITE VOLTS<-15.00/15.00>  
After the two voltages are entered, the required offset voltage is calculated for both signal strength  
channels and the polarity (NEGitive or POSitive) is displayed. The channel that would be most  
appropriate for the entered voltage characteristics is noted by a “*”.  
Note that if the entered values are out of range or the two values are too close together to allow a  
meaningful calculation the following message is displayed:  
INVALID ENTRY <MODE>EXIT & TRY AGAIN  
The screen may then be exited and reentered to start data entry again.  
122  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.5 Limits Maintenance  
AZIM CW:0 CCW:1 STOW:0 (0-OFF) LIMITS  
ELEV UP:1 DN:1 STOW:1 (1- ON) ACTIVE  
POL CW:0 CCW:1 STOW:*  
<BKSP>MAKE LIMITS INACTIVE  
<MODE>EXIT  
The limits maintenance screen shows the current state of each limit switch as sensed by the RC3000’s  
microcontroller. The state of each limit is shown as 0 if off or 1 if on. An * is displayed if the particular  
limit switch is not relevant for the particular mount (there is no POL STOW switch in the above example).  
<BKSP>MAKE LIMITS INACTIVE <MODE>EXIT  
From this screen the user may inactivate software logic that prevents axis movement due to a limit switch  
by pressing the BKSP switch. Note that inactivating limits should be done with caution. Whenever limits  
are “INACTIVE” the alarm system will flash the following:  
** WARNING – LIMITS INACTIVE **  
The limit switch logic may be returned to “ACTIVE” by pressing BKSP again.  
Note that even if software limit sensing is made “INACTIVE”, there are cases where movement of an axis  
may still be inhibited by hardware logic (sensing the state of limit switches) on the analog drive board.  
Good knowledge of how the various limit switches in a system are mechanized is required to determine if  
the limits inactive state will help in debugging any problems.  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.6 GPS Serial Port Diagnostics  
This screen allows the user to ascertain if the GPS receiver is communicating correctly with the RC3000.  
<BKSP> TO FREEZE DISPLAY  
GPS COMM  
$GPRMC,133544,V,3856.0856,N,09444.8377,  
W,000.0,000.0,080499,003.6,E*7B≡≡$GPGGA,  
190449,3856.0856,N,09444.8377,W,0,00,,,M  
The screen shows the raw ASCII data coming from the GPS receiver. If there is correct communication  
established with the GPS, somewhere in the lines of displayed characters the strings “GPRMC” and/or  
“GPGGA” should be recognizable. GPRMC and GPGGA are names of data sentences defined by the  
NMEA-0183 standard. These two sentences are transmitted once a second by the GPS receiver.  
$GPRMC,133544,V,3856.0856,N,09444.8377, W,000.0,000.0,080499,003.6,E*7B  
NOTE: nine characters beyond the GPRMC string there will be either an “A” or a “V”. “A” indicates that  
the GPS receiver is generating a valid navigation solution. A “V” indicates conditions aren’t correct yet for  
calculating a navigation solution. This latter condition may indicate that the GPS receiver does not have  
a good enough view of the sky or that the receiver has not been powered on long enough to generate a  
solution. Under normal conditions the receiver should generate a solution within 2 minutes of powering  
on. If the unit has not been powered on for a long time and/or the receiver has been moved a  
considerable distance from its last known location, the “time-to-first-fix” may be up to 4 minutes.  
Another sentence “$PGRMT” is transmitted once a minute.  
If no characters are being received from the GPS, the message “INITIALIZING GPS” will remain on line 4  
of the display. Normally this message will go away within 10 seconds of entering this mode.  
3.3.2.7 Fluxgate Serial Port Diagnostics  
This screen allows the user to ascertain if the fluxgate compass is communicating correctly with the  
RC3000.  
FLUXGATE  
$HCHDM,266.1,M*2A≡≡$HCHDM,266.0,M*2B≡≡  
HCHDM,266.0,M*2B≡≡$HCHDM,266.0,M*2B≡≡$  
$HCHDM,266.0,M*2B≡≡ HCHDM,266.0,M*2B≡≡  
The screen shows the raw ASCII data coming from the fluxgate compass. If there is correct  
communication established with the compass, somewhere in the lines of displayed characters the string  
“HCHDM” should be recognizable.  
Following the “HCHDM” should be a number indicating the current magnetic heading (266.0 in example)  
the compass is reading. If this value is 800.0, it indicates the fluxgate’s sensor is either saturated by an  
unreasonably high magnetic field or the magnetic field strength is unreasonably low. If the “800.0”  
number is seen, the placement of the fluxgate should be checked.  
124  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.8 MOVETO  
The MOVETO mode is intended to provide an easy way to move the antenna to a certain position for  
doing testing such as cutting antenna patterns. This mode is also useful for tuning up automatic  
movements.  
AZIM:-123.4 ( 123.4)  
MOVETO  
ELEV: 41.5 ( 41.5) <5>SENSOR:PRIMARY  
POL: -13.3 ( -13.3) <3>SPEED:FAST  
SET <1>AZ <2>EL<6>POL <4>START MOVE  
The current azimuth, elevation and polarization angles are displayed. When the mode is first entered, the  
current positions are shown as the target positions. After setting target positions and setting the desired  
speed, the automatic movement may be initiated by pressing the 4 key.  
<5>SENSOR:PRIMARY  
The state of this field when this mode is entered will be “PRIMARY”. This means that the displayed  
angles and entered targets are generated and referenced to the axis sensor that generates angles. For  
instance, the typical primary elevation sensor is the electronic inclinometer.  
If the mount is equipped with higher resolution sensors such as resolvers or pulse sensors, toggling the  
field to “SECONDARY” will cause the display and target to change to an integer representative of the  
high resolution sensor. This mode of operation allows actions such as the small movements made during  
inclined orbit tracking to be simulated.  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.9 Fluxgate Calibration Procedure  
The fluxgate compass calibration procedure is performed to compensate for sources of hard and soft iron  
magnetic deviations from the host mount. Review the discussion on the importance of selecting a  
suitable site for performing the calibration in section 2.4.1.  
NOTE: the fluxgate compass must be in a level orientation to perform a good calibration.  
The user is prompted to hit the Enter key to begin the procedure. If the user is not confident that the  
location for calibration is adequate or does not have the ability to move the mount, the procedure may be  
exited by hitting the Mode key.  
8 PT COMPASS CAL  
<ENTER> TO BEGIN CAL <MODE> TO EXIT  
Fields to show the quality of the calibration are displayed. Until the calibration is finished, an “*” is  
displayed. Following successful completion of the procedure, the scores reported by the fluxgate  
compass will be displayed. Each procedure has unique messages for prompting the user on how to  
proceed.  
MOVE TO INITIAL HEADING & <ENTER>  
ROTATE 45 DEG.(START + 45/90/135/180/225/270/315) & <ENTER>  
The eight point calibration procedure requires the mount to be moved 45 degrees at a time. The first  
prompt asks for the mount to be moved to an initial position. After moving to the requested position, the  
user must let the compass know by pressing the Enter key. These steps will be repeated for 45, 90, 135,  
180, 225, 270 and 315 degrees.  
The requirement is not that the mount be initially placed at a true heading of 0 degrees initially. Rather  
the value indicates the number of degrees from the starting orientation. Also the movement each time  
needs only be +/- 15 degrees from the requested 45 each time. Marking out eight equidistant bearings  
before the procedure is performed may be beneficial.  
MOVEMENT MAY STOP-PERFORMING CALCULATION  
When the calibration has collected enough data, the “movement may be stopped” message is displayed.  
Do not mode out of calibration until the calibration finished message is displayed.  
CALIBRATION FINISHED,<MODE> TO EXIT  
This message indicates the fluxgate has finished performing its calibration calculations. At this time new  
calibration scores are displayed.  
8 PT COMPASS CAL  
CAL QUALITY:8  
MAG ENVIRON:7  
(0-9,>6 PREFFERRED)  
(0-9,>5 PREFFERRED)  
CALIBRATION FINISHED, <MODE> TO EXIT  
COMM ERROR  
At any time during the calibration procedures the RC3000 detects an abnormal response from the  
fluxgate, the communication error message is displayed. Exit the procedure by pressing the mode key.  
126  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.10 Shake  
The SHAKE mode performs repetitive mount movements. The SHAKE mode is for support of mount  
testing and for automatic mount demonstrations such as trade shows. The SHAKE mode is only  
available if expert access is enabled.  
The SHAKE mode implements a repetitive sequence of three “moves”. Each “move” is programmed with  
azimuth, elevation and polarization targets. Moves # 1 and 2 proceed in the order elevation, polarization  
and azimuth. Move # 3 proceeds in the order of azimuth, polarization and elevation to accommodate a  
“stow-like” sequence. NOTE: if polarization movement is not desired, set the polarization type (see  
polarization configuration) to “circular”. When SHAKE is selected, the following screen appears.  
AZ 1: -40.0 2: 50.0 3: 0.0  
SHAKE  
EL 1: 30.0 2: 40.0 3: -67.5 CYCLE: 100  
PL 1: -10.0 2: 10.0 3: 0.0 DELAY: 1  
<1>START <CONFIG-SHAKE>EDIT <MODE>MAINT  
This opening screen shows the programmed values for the SHAKE mode. The azimuth(AZ),  
elevation(EL) and polarization(PL) targets for each of the three “moves” is displayed. Also displayed is  
the programmed number of movement CYCLES to accomplish and the time in seconds to DELAY  
between each “move”. The pattern the above move targets describe is shown in the following figure.  
Elevation  
40.0  
30.0  
Azimuth  
-40.0  
0.0  
50.0  
The programming of the targets, cycles and delay is accomplished via the SHAKE configuration screen  
(3.3.1.17). To initiate the SHAKE sequence, press the Pol CCW/1 key. If you wish to modify the SHAKE  
parameters go to the CONFIG-SHAKE mode. To exit out of SHAKE press the Mode key.  
When SHAKE is started the following screen appears:  
AZIM: 0.2  
ELEV: -55.3  
POL: 0.6  
SHAKE  
DELAY  
CYCLE: 1/ 5  
<STOP>HALT MOTION <MODE>MAINT  
As each axis moves its header (AZIM, ELEV, POL) flashes and the current position is updated. The  
CYCLE field shows the current_cycle / total_cycles . When the SHAKE function is delaying between  
moves, "DELAY” is displayed.  
Movement may be stopped at any time by pressing the Stop or Mode keys.  
127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.3.2.11 Configuration Item Record  
Selecting the Stop/. key from the MAINTENANCE screens triggers a process that will transmit the current  
configuration item values via the remote control port.  
If the controller has the remote control option, the values will be transmitted at the baud rate set in the  
Remote configuration screen. Otherwise the default rate of 9600 baud will be used. The data will be sent  
out as 7 data bits with even parity. The data is sent out as a simple set of ASCII characters with each line  
terminated by a linefeed and carriage return. It is intended that a simple program such as HyperTerminal  
be used to pull in the data.  
The output's first three lines will contain date, time, mount type, software version number, etc. Next the  
configuration items will be sent out per configuration screen. For each configuration item, the field shown  
on the screen, the item value and the bottom row prompt associated with the item will be sent on one line.  
The following is an example output showing the first two configuration screens.  
RC3000 CONFIGURATION ITEMS  
20OCT05 20:49:21  
V1-GTR 1.54  
SYSTEM DEFINITION  
SN: 1234 SERIAL NUMBER<1-9999> (0=NOT ENTERED)  
GPS:  
COMPASS:  
MODE:  
ANT_SIZE:  
1 <1>GPS PRESENT <0>NOT PRESENT  
1 <0>NONE <1>TRUCK MOUNT <2>ANTENNA MOUNT  
2 <1-LOCATE 2-MENU 3-MANUAL 4-VSAT 5-POS>  
244 ANTENNA SIZE <1-9999 CM>  
WAVEGUIDE:  
0 WAVEGUIDE SWITCH <1>PRESENT <0>NONE  
ELEVATION CALIBRATION  
REF_V: 1.69 SET ZERO VOLTAGE <0.50 - 4.50>  
OFF:  
UP:  
DOWN:  
0.0 ELEVATION OFFSET <-25.0/+25.0 DEGREES>  
90 SET UP LIMIT <0-90 DEGREES>  
0 SET DOWN LIMIT <0-90 DEGREES>  
SF: 50.00 SCALE FACTOR <30.00 - 60.00 mV/deg>  
LOOK:  
1 ELEV LOOK CONFIGURATION <1>HIGH <0>LOW  
NOTE: During the time (up to 15 seconds) its takes to output all configuration item values, there will be no  
action apparent at the RC3000's front panel. The user should monitor his recording program to  
determine when the process is finished. Note also that this process will disrupt normal remote control  
actions so any other monitor and control applications should be paused during this process.  
The intent of this feature is to provide a convenient way to record configuration item values following the  
calibration of the controller. Before contacting RCI for technical support, it would also be useful to record  
the current configuration items status and send the file to RCI.  
128  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
3.4 Alarm Displays  
The alarm system monitors important system parameters and flashes a message on the bottom line of  
the LCD display if an error is found. The parameters monitored include the condition of the lithium  
battery, status of the azimuth and elevation antenna drive systems, and the values of certain variables.  
Some error codes have priority over others. Alarm conditions are sampled sequentially, with the highest  
priority sampled first. As corrective action is taken for each error, the code is eliminated, and if there is a  
lesser error, it will then appear.  
Many of the alarm messages described in this section are caused by corrupt CONFIG mode items. Note  
that access to certain CONFIG mode items is controlled by the value of other CONFIG mode items. See  
the first few paragraphs of section 4.10 for an explanation of the role of controlling CONFIG mode items.  
If the value of a controlling CONFIG mode item is such that access to other CONFIG mode items is  
restricted, corrupt values of those other CONFIG mode items can still generate an alarm message.  
Access to the corrupted item is only available if the controlling item is changed to allow it.  
All of the CONFIG mode items must be initialized to a valid value, even if the feature associated with that  
CONFIG mode item is disabled. For example, even if REMOTE mode is disabled, the Comm Port Baud  
Rate and Comm Port Address CONFIG mode items must still be initialized properly.  
LOW BATTERY  
The RC2000C constantly monitors the level of the lithium battery. When the power level is low, this error  
code will appear. Replace the battery with a Duracell DL2450. Make sure that the unit is unplugged  
from the AC power before removing the cover to change the battery. Take care to hold the battery tab  
away from the battery housing while replacing the battery, and it will not be necessary to reprogram the  
memory. Since there is a chance that the non-volatile memory will be corrupted when the battery is  
changed, please refer to Appendix A entitled 'Restoring the Non-Volatile Memory' before changing the  
battery.  
ANT AZIM, ANT ELEV, ANT POL  
These alarm messages indicate that an error has been detected for the axis referenced in the alarm  
message. When one of these alarms are detected, the axis is disabled. Go to RESET mode (section  
5.7) to view the actual fault condition which was detected and to clear the fault.  
A Reset mode JAMMED indication may mean that the drive breaker is open. This can occur if  
simultaneous movement is enabled, and the total current draw from both motors exceeds 8 amps. Reset  
the breaker by pressing it back into place, and disable Simultaneous AZ/EL movement via CONFIG  
mode. See Section 5.10.2  
COMM PORT  
This error (caused by an incorrect checksum) indicates that the value of at least one of the following  
CONFIG mode items has been corrupted: Remote Mode Enable, Comm Port Baud Rate, or Comm Port  
Address. Remote Mode Enable is the controlling item for this group of CONFIG mode items - it must be  
enabled to allow access to the Comm Port Baud Rate and Comm Port Address CONFIG mode items.  
See section 5.10.3.  
POL OPTIONS  
This error (caused by an incorrect checksum) indicates that the value of at least one of the following  
CONFIG mode items has been corrupted: Rotating Feed Present, Rotating Feed CW Limit, Rotating  
Feed CCW Limit, or Rotating Feed Jog Duration. The Rotating Feed Present item is the controlling item  
for this group of CONFIG mode items - it must be set to YES to allow access to the other items. See  
sections 5.10.6 and 3.3.  
129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 3  
Detailed Operation  
AZ/EL OPTIONS  
This error (caused by an incorrect checksum) indicates that the value of at least one of the following  
CONFIG mode items has been corrupted: Az/El Drive Options Enable, Az/El Fast Slow Threshold, Az/El  
Retry Attempts, Az/El Fast Deadband, Az/El Slow Deadband, Azim Coast Threshold, Elev Max Position  
Error, or Simultaneous Az/El Enable. The Az/El Drive Options Enable CONFIG mode item is the  
controlling item for most members of this group of CONFIG mode items - it must be enabled to allow  
access to the other items. See sections 5.10.2 and 5.10.7.  
TIME/DATE  
This alarm code indicates either the Time or Date is corrupt. The time and date are entered via CONFIG  
mode. See section 5.10.8.  
TRACK CONFIG  
This error code indicates that at least one of the following CONFIG mode items is corrupt: Max Track  
Error, Search Enable, or Search Width. See section 5.10.11  
130  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 4  
Troubleshooting  
4.0 TROUBLESHOOTING  
This section provides tips for debugging typical problems. There are many interfaces between the  
RC3000 and position sensors, limit switches, mechanical components of the mount, other satellite  
equipment, etc. Some problems are due to interactions that are not readily apparent. Review all of the  
troubleshooting sections to see if a situation similar to yours is described.  
4.1 Limit Switches  
The various limit switches serve as safety interlocks to prevent mount damage. The RC3000 checks for  
limit conditions via both software and a Programmable Logic Device on the analog board. The following  
table summarizes the interlock logic employed:  
LIMIT  
INTERLOCK LOGIC  
Azimuth STOW  
Elevation movement below the Elevation DOWN position is not allowed unless the  
Azimuth STOW condition is active.  
Azimuth CCW  
CCW movement in azimuth is not allowed when the azimuth CCW condition is  
active.  
Azimuth CW  
Elevation DOWN  
Elevation STOW  
CW movement in azimuth is not allowed when the azimuth CW condition is active.  
No azimuth movement is allowed when the Elevation DOWN condition is active.  
No further elevation down movement is allowed when the Elevation STOW  
condition is active. NOTE: when the Elevation STOW condition is active, the  
RC3000 internally generates an Elevation DOWN condition.  
No further elevation up movement is allowed when the Elevation UP condition is  
active.  
Elevation UP  
Polarization CCW  
Polarization CW  
CCW movement in polarization is not allowed when the polarization CCW  
condition is active.  
CW movement in polarization is not allowed when the polarization CW condition is  
active.  
Polarization STOW Elevation movement below the Elevation DOWN position is not allowed unless the  
Polarization STOW condition is active. NOTE: only certain mounts mechanize the  
Polarization STOW limit switch – check appendix B for your mount.  
Many problems are caused by limit switches either activating incorrectly or the RC3000 not sensing the  
limit switch’s state correctly. The following are some examples of problems caused by limit switch  
sensing:  
Mount will move down in elevation but not up. Check that the Elevation UP limit switch is not stuck in  
the active state.  
Mount will not move below the DOWN elevation limit. Check that the Azimuth STOW limit switch has  
activated correctly. Also check the polarization STOW limit switch if the mount is so equipped.  
Mount will only move up in elevation. Check that the Elevation STOW limit switch is not stuck in the  
STOW condition.  
Mount is above the Elevation DOWN position but will not move in azimuth. Check that the Elevation  
DOWN limit switch is not active.  
Failure of a limit switch to activate properly may be due to the limit switch mechanism itself, cabling to the  
limit switch or failure of the RC3000 to sense the limit switch correctly. Isolating the problem to the  
RC3000 or switch/wiring may be accomplished by jumpering the appropriate pins on the J3 connector.  
NOTE: only the Elevation STOW/DOWN/UP, Azimuth STOW and Polarization STOW (if applicable) are  
mechanized via discreet limit switches – Azimuth CW/CCW and Polarization CW/CCW limits are  
mechanized differently and will be discussed later.  
131  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 4  
Troubleshooting  
After removing the wiring harness from J3, the first thing to check is that 12 VDC is present at the “+” pin  
of each limit switch. Pins 2,9,10 and 11 should have +12 VDC present (see 2.2.4 – J3 wiring diagram.)  
NOTE: pin 5 should also have +12 only if pins 11 and 13 are jumpered. If +12 VDC is not present, there  
is a power supply failure within the RC3000. Contact your vehicle integrator, mount manufacturer or RCI  
for further instructions on how to proceed.  
If +12 VDC is present, the limit switch sensing logic may be checked by jumpering between the  
appropriate pins and noting if the limit switch condition is sensed correctly by the RC3000. The state of  
the limit switches should be monitored via the Limits Maintenance (3.3.2.5) screen. The following table  
shows which pins to jumper and state that should be seen via the Limits Maintenance screen.  
LIMIT  
J3 PINS  
9,7  
5,6*  
11,13  
10,14  
1,2  
JUMPERED  
OPEN  
Azimuth STOW  
Elevation DOWN  
Elevation STOW  
Elevation UP  
1
0
0
0
0
0
1
1
1
1
Polarization STOW  
* - To test Elevation DOWN, pins 11 & 13 must be jumpered to simulate elevation not stowed  
The azimuth CW/CCW and polarization CW/CCW limit conditions are mechanized by potentiometers  
inside the RC3000 that should be set to correspond to the axis voltage at the limit conditions. If any of  
these limits appear to be activating at the wrong time, check the setting of the potentiometers as  
described in the azimuth and polarization calibration procedures (2.3.3 and 2.3.4.)  
4.2 Motor Drive  
Axis JAMMED error displayed. A jammed error indicates that the axis was commanded to move, but the  
RC3000 did not sense any movement within several seconds. A jammed condition may indicate one of  
several conditions:  
The mount’s mechanical drive mechanism is physically jammed. Inspect the mount to determine if  
some mechanical problem (slipped gears, etc) exists. Unusual conditions such as icing may also cause  
the mount to jam.  
The mount’s position is not being sensed correctly by the RC3000. After resetting the drive error, go  
to MANUAL mode and attempt to jog the axis in question. If the axis does move, check to see if the axis’  
displayed position is updating. If the RC3000 doesn’t sense movement, it will declare a jam even though  
the axis is moving.  
The RC3000’s motor drive is failing to output the required voltage to move the axis. Attempt to  
move the axis in question via the MANUAL mode. There are several things to note:  
1) When a jog key is pushed, can relays inside the RC3000 be heard activating? If no relays are heard,  
a limit switch condition may be present that disallows movement in the axis in question. Review the  
above limit switch discussion.  
2) Can the axis move in slow speed but not in fast? If this is the case, the fast voltage setting or current  
limit setting of the motor drive may need to be adjusted.  
3) Is there voltage present at the appropriate J7 pins when the axis jog is attempted? If no voltage is  
present, there’s the possibility that a fuse inside the RC3000 has blown (take care inside unit => must  
disconnect power, etc.)  
If a fuse is blown, replace with the appropriate fuse. Reconnect J7 and remove the drive wires at the  
motors. Attempt to jog the axis. If the fuse blows again, the drive cables should be checked for a short.  
If the fuse does not blow, the motor should be checked.  
The axis’ motor is damaged. If possible, attempt to apply DC voltage to the motor from an external  
source such as a series of batteries. If the motor will not move, the motor is probably damaged.  
132  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 4  
Troubleshooting  
When a manual jog key is released, the axis continues moving for about 5 seconds. This condition  
is indicative of a drive relay failure inside the RC3000. The RC3000 has a “safety” relay in series with the  
normal drive relays that opens 5 seconds after any commanded movement is stopped.  
4.3 Automatic Movements  
The mount does not go below the elevation DOWN limit when stowing. To proceed below the  
DOWN limit, the azimuth stow limit must be active. The RC3000 drives to the azimuth stow position and  
checks to confirm that the azimuth stow switch is active. If the azimuth stow limit is not active, the  
controller will make several attempts to find the stow switch in the immediate vicinity.  
If the azimuth stow switch is not sensed in the correct position, check that the limit switch is working  
properly. There is also the possibility that the azimuth potentiometer has slipped causing the sensed  
stow position not to be in the same place the stow switch is active.  
On some mounts, the polarization stow switch must also be active before movement below the DOWN  
limit may occur.  
When stowing, the mount reaches the elevation stow position but the elevation motor continues  
to run. The stow routine does not stop until the elevation stow switch has been activated. If the  
elevation stow switch is faulty, the controller will continue to drive down. The RC3000 does implement a  
5 minute “timeout” of the elevation axis drive in an attempt to prevent elevation motor “meltdown”.  
The mount begins an automatic movement (stow, deploy, etc.) but generates an “axis jammed”  
error. All automatic movements move to a “target” location. If far enough away from the target, the move  
will initially be done in the FAST speed for the axis and then switch to SLOW when close to the target. If  
the SLOW speed has been set too low, the axis may jam. Attempt to move the axis in SLOW speed from  
the MANAUL mode to duplicate the situation. If SLOW speed seems to be the problem, adjust the drive  
voltage up as discussed in 2.3.5.  
4.4 GPS  
The interface between the RC3000 and the optional GPS receiver is via an RS-232 serial port. The data  
stream from the GPS receiver is parsed in multiple places in order to receive latitude, longitude and time  
data. The following messages may be displayed when the RC3000 is attempting to receive data from the  
GPS:  
** NO GPS PRESENT **. This message indicates that the gps_present item in the System Components  
(3.3.1.3) configuration item as been set to 0 indicating that no GPS is attached to the RC3000. No  
attempt will be made to parse GPS data in this state. If a GPS is truly attached, set the gps_present item  
to 1. Note that if the GPS option was not purchased with the controller, the gps_present item will not be  
allowed to be set to 1.  
**INITIALIZING** or STARTING GPS. This message indicates that the RC3000 has sent a command to  
the GPS receiver to start communication. Normally this message should only appear momentarily until  
the first response from the GPS has been received.  
**GPS OFFLINE**. This message means that no data has received from the GPS. If this message  
persists, troubleshooting of GPS communications as described below should be performed.  
To check that communication with the GPS is occurring, move to the GPS Serial Port Diagnostics  
(3.3.2.6) screen. The data on the screen should update approximately once a second. If no data is being  
displayed or the GPRMC data stream described in 3.3.2.6 is unrecognizable, the integrity of the cabling  
between the RC3000 and the GPS receiver should be checked.  
133  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 4  
Troubleshooting  
**NO GPS NAV**. This message means that correct data streams are being received from the GPS, but  
the received data indicates that the GPS has not yet formulated a navigation solution (latitude and  
longitude.)  
Under normal conditions the GPS should generate a navigation solution within 4 minutes of powering on.  
If the GPS has not been powered on for several weeks or if the GPS has been moved a considerable  
distance from the last position that it generated a navigation solution, the time it takes to generate a  
solution may go beyond 4 minutes. When the GPS is powered up, it assumes it is at the same lat/lon as  
when it was powered down. It also has stored the ephemeris data it had at that time. While powered  
down the GPS’ real time clock will continue to timekeep.  
The GPS will not generate a navigation solution if it cannot “see” 4 satellites. Check that the GPS unit has  
a clear view of the sky. If parked next to a tall building, even if the GPS has a seemingly clear view of the  
sky, the current GPS satellite constellation may be such that too many satellites are masked.  
RF Interference. Strong interference from transmitting antennas close to the GPS receiver may also  
disrupt the receiver’s ability to “see” satellites. Attempt to turn off transmitting sources (satellite phones,  
etc.) close to the GPS antenna to see if that affects the GPS’ performance.  
4.5 Fluxgate Compass  
The interface between the RC3000 and the optional fluxgate compass is via a RS-232 serial port.  
NO COMPASS. This message indicates that the compass_present item in the System Components  
(3.3.1.2.1) configuration item has been set to 0 indicating that no compass is attached to the RC3000.  
No attempt will be made to parse compass data in this state. If a compass is truly attached, set the  
compass_present item to 1 or 2. Note that if the compass option was not purchased with the controller,  
the compass_present item will not be allowed to be set to a value other than 0.  
“*****” in compass data field. The “*****” string in a position where compass data should normally  
appear indicates that the RC3000 cannot parse a valid heading string from the compass. Use the  
Fluxgate Serial Port Maintenance screen (3.3.2.7) to see if data from the compass is arriving at the  
RC3000.  
If the heading string within the compass data shows “800.0” instead of a valid heading value (0.0 to  
359.9), the compass is reporting that the magnetic field it is sensing is either too high or too low. Usually  
this means that another strong magnetic field is close to the compass. Try to relocate the compass away  
from any sources of magnetic fields (generators, air conditioners, etc.) Sometimes equipment that  
normally doesn’t generate a magnetic field may become magnetized by some event such as a nearby  
lighting strike.  
COMM ERROR during compass calibration. During a compass calibration procedure, the RC3000  
sends commands to the compass and checks for correct replies. The COMM ERROR message  
indicates that a) a response from the compass was not received correctly or b) the calibration command  
from the RC3000 was not received by the compass. First check communication from the compass as  
above. If correct data is coming from the compass, then inspect the wiring to determine if the transmit  
(from RC3000 to compass) line is correct.  
134  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC3000 Antenna Controller  
Chapter 5  
Drawings & Schematics  
5.0 DRAWINGS & SCHEMATICS  
ITEM  
SCHEMATIC NAME  
# OF PAGES  
RC3000 Main Enclosure  
System Interconnects  
Digital Board  
1
6
3K-A2-SYS_CONNECT  
B-3KDIG1B  
3
Analog Board  
B-3KAN5  
13  
6
Drive Board  
B-3KDPB04  
Resolver Board  
3KRLSVR3  
3
NOTE: This page is in the manual in order to generate the correct page number for the table of contents.  
All schematics will be compiled in their own file (starting at this page number) to be appended to this file.  
135  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Home Theater Server 243066 Series A User Manual
Grizzly TV Video Accessories G8144Z User Manual
Harman Kardon Blu ray Player BDS770 User Manual
Heath Zenith Work Light 598 1189 01 User Manual
Hotpoint Oven GE750DX User Manual
HP Hewlett Packard Switch 531671 001 User Manual
HP Hewlett Packard Tablet Accessory 344524 001 User Manual
HTC Cell Phone F5151 User Manual
Hunter Fan Humidifier 38200 User Manual
Husqvarna Lawn Mower YTH2146XP User Manual