HP Hewlett Packard Security Camera XP256 User Manual

HP NetServer LPr  
with  
XP256 (Fibre Channel or SCSI)  
Cluster Configuration Guide  
08 February, 2000  
Introduction  
This document defines the supported HP NetServer LPr configurations with the XP256 and Microsoft  
Cluster Server. These configurations minimize single points of failure (SPOF), provide maximum  
availability, and have been certified by Hewlett-Packard or Microsoft. This guide is prescriptive; it  
describes the configurations supported by HP. Any deviance to these configurations can result in an  
inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore  
will not be supported by HP.  
What’s Defined in a Cluster  
Cluster  
SPUs  
Local and Shared Storage  
Intra-cluster and Client LANs  
Shared Storage Cabling  
Cluster  
Type of SPUs  
HP NetServer LPr.  
Each node must be the same model SPU, but may have different clocks  
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).  
Number of nodes  
Shared Storage  
LANs:  
2
XP256 with FC or SCSI connections. See Shared Storage below.  
Client LAN  
Any NIC that is HP and Microsoft approved. See Client LAN below.  
HP D5013A with crossover cable. See Intra-cluster LAN below.  
Intra-cluster  
(Heartbeat) LAN  
Power source  
Direct from power mains, power conditioner or uninterruptible power  
supply (UPS) using any power conditioner or UPS.  
System software:  
Navigator version  
Operating System  
Service pack  
L.16.05 or later  
Microsoft Windows NT Server 4.0, Enterprise Edition or later  
SP5 or later  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
XP256 Disk Array  
Microcode  
43.12 (Direct Connect)  
44.14 (All Configs)  
Open Volume Sizes  
(LDEVs)  
VOL TYPE SIZE MAX EXTENDED LUN SIZE  
Open 3*n  
Open 8*n  
Open 9*n  
2.4G  
7.2G  
7.3G  
2.4G x 36= 86.4G  
7.2G x 36= 259.2G (where “n”= 1-36)  
7.3G x 36= 262.8G  
Disk Capacities  
RAID levels  
15GB, 36GB, 47GB  
1 & 5  
Max number of LUNs  
Port Host Modes  
8 shared LUNS per cluster  
08 (Fibre)  
00 (SCSI)  
Port Fabric Modes  
Using SVP (in MODIFY mode), go to SCSI PATH/FIBRE/TOPOLOGY.  
Turn FABRIC and LOOP to ON.  
SCSI Cables  
2.5 meter  
Either of the 2 HP SCSI cables from the following list:  
C2924A 68 pin HD Male to 68 pin HD Male  
C2925A 68 pin HD Male to 68 pin HD Male  
10 meter  
FC Cables  
2 meter  
Any 2 HP shortwave cables from the following list:  
A3583A  
A3531A  
A3735A  
A3736A  
16 meter  
50 meter  
100 meter  
Shared Storage Configurations  
Point to Point  
Direct Fibre Channel or SCSI connections. Each SCSI Port on XP256 has  
two available connection points (internal logical Y connection); one is  
cabled to Server #1 of the cluster, the other to Server #2 (see diag 1, page  
5).  
Fibre Channel Hub  
Model  
A3724A HP-10 port Short Wave FC Hub  
A4839A HP-10 port Long Wave FC Hub  
1 per SPOF cluster  
No. of hubs  
No. of clusters/hub  
1 cluster on 1 hub  
Fibre Channel Switch  
Model  
A5223A (non-cascading) or A5224B (cascading)  
A5624A/AZ Brocade 2800 FC Switch  
Fabric Support  
No. of switches  
FL Port (Turn EPL to OFF for desired ports)  
1 per SPOF cluster, 2 per SPOFless cluster  
No. of clusters/switch SPOF: 1, SPOFless: 4 cluster nodes (See pg.5)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
LANs  
Intra-cluster (Heartbeat) LAN  
Client LAN  
LAN connection  
HP D5954A crossover cable or  
equivalent  
Any LAN  
The intra-cluster LAN may only be  
used for cluster node communication  
via a crossover cable. It may not be  
used for client communication.  
NIC:  
Model  
HP D5013A (10/100TX PCI)  
3.27.00.0001 or later  
Any that is on both the HP Tested  
Products List and the Microsoft  
Hardware Compatibility List.  
Driver  
Any driver  
NOTE If the NIC used is the  
same as the Intra-cluster LAN,  
then the Client LAN must use the  
same driver as the Intra-cluster  
LAN.  
No. of NICs  
SPU I\O slot  
1
1 minimum  
P2  
P4  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Shared Storage Cabling  
This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer  
LPr and the XP256. Only these cabling configurations and cables are supported.  
DIAGRAMS SHOWING THE SUPPORTED CONFIGURATIONS  
LPr  
LPr  
LPr  
LPr  
Hub/Switch  
XP256  
XP256  
LPr  
LPr  
1a  
LPr  
1b  
LPr  
2b  
LPr  
LPr  
2a  
Switch  
Switch  
XP256  
LPr  
4a  
LPr  
3a  
LPr  
3b  
LPr  
4b  
XP256  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Accessories PD261467A User Manual
Graco Patio Furniture 9651 9744 User Manual
Graco Scuba Diving Equipment 307212ZAC User Manual
Gyration Mouse TM ULTRA CORDLESS OPTICAL MOUSE User Manual
Hotpoint Cooktop EH12 User Manual
Hotpoint Cooktop GF941 User Manual
HP Hewlett Packard TV Converter Box HP 8590B User Manual
Husqvarna Snow Blower 1027STE User Manual
Icom Car Amplifier ic pw1 User Manual
I O Magic Computer Hardware MagicSpin User Manual