Goodman Mfg Furnace GMVM96 User Manual

gMVM96  
& gcVM96  
Multi-Position, Modulating  
Variable-sPeed gas Furnace  
uP to 96% aFue  
Standard Features  
• Aluminized-steel, dual-diameter tubular heat exchanger  
• Stainless-steel secondary heat exchanger  
• Up to 96% AFUE  
• ComfortNetTM Communicating Systems compatible  
• Self-calibrating, modulating gas valve operates with two-  
stage or single-stage thermostats  
• Efficient and quiet variable-speed circulator motor gently  
ramps up or down according to heating or cooling demand  
• Durable Silicon Nitride igniter  
• Furnace control board with self-diagnostics, color-coded  
low-voltage terminals and provisions for electronic air  
cleaners and humidifiers  
• Low constant fan speed allows homeowner to quietly circu-  
late air throughout the home. This setting costs as little as a  
100-watt light bulb to operate.  
• Dual-certified for sealed combustion direct vent (2-pipe) or  
non-direct vent (1-pipe) applications  
• Auto-Comfort and enhanced dehumidification modes  
provide energy savings and additional comfort during the  
cooling months  
• Easy-to-install top venting is standard; alternate flue/vent  
located on right  
• Quiet two-speed induced draft blower  
• All models comply with California NOx emissions standards  
Cabinet Features  
• Fully insulated heavy-gauge steel cabinet with durable baked-  
enamel finish  
• Foil-faced insulation lines the heat exchanger section  
• Designed for multi-position installation: upflow, horizontal  
left, or right  
• Airtight solid bottom for side-return applications and easy-cut  
tabs for effortless removal in bottom air-inlet applications  
• Convenient left or right connection for gas and electric service  
• Coil and furnace fit flush for most installations  
Contents  
Nomenclature....................................................................2  
Product Specifications .......................................................3  
Dimensions ........................................................................4  
Airflow Data .......................................................................6  
Wiring Diagrams ..............................................................11  
Thermostats ....................................................................12  
Accessories .......................................................................12  
*
for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed  
within 60 days of installation. Online registration is not required in California or Québec.  
SS-GMVM96  
6/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRoDucT sPeciFicATions  
sPeciFicATions  
GMVM96  
0603BX  
GMVM96  
0805CX  
GMVM96  
1005DX  
GMVM96  
1155DX  
GCVM96  
0604CX  
GCVM96  
0805DX  
GCVM96  
1005DX  
Heating Capacity  
High Fire Input¹  
60,000  
57,600  
30,000  
28,800  
96  
80,000  
76,800  
40,000  
38,400  
96  
100,000  
96,000  
50,000  
48,000  
96  
115,000  
109,250  
57,500  
54,625  
95  
60,000  
57,600  
30,000  
28,800  
96  
80,000  
76,800  
40,000  
38,400  
96  
100,000  
95,000  
50,000  
47,500  
95  
High Fire Output¹  
Low-Fire Steady-State Input¹  
Low-Fire Steady-State Output¹  
AFUE²  
Tons AC @ 0.5” ESP  
Temperature Rise Range (°F)  
Circulator Blower  
Size (D x W)  
1.5-3.0  
20-50  
2.0-5.0  
35-65  
2.0-5.0  
35-65  
2.0-5.0  
35-65  
1.5-4.0  
20-50  
2.0-5.0  
20-50  
2.0-5.0  
25-55  
10" X 8"  
3/4  
11" X 10"  
11" X 10"  
11" X 10"  
10"X 10"  
3/4  
11" X 10"  
11" X 10"  
Horespower @ 1050 RPM  
Speed  
1
Variable  
3"  
1
Variable  
3"  
1
Variable  
3"  
1
Variable  
3"  
1
Variable  
3"  
Variable  
2"  
Variable  
2"  
Vent Diameter³  
No. of Burners  
3
4
5
5
3
4
5
Disposable Filter (in²)  
Electrical Data  
576  
960  
960  
972  
641  
854  
854  
Min. Circuit Ampacity (amps)⁴  
Max. Overcurrent Protecꢀon⁵  
Ship Weight (lbs)  
6.0  
15.0  
135  
14.2  
15.0  
145  
14.2  
15.0  
170  
14.2  
15.0  
170  
6.0  
15.0  
139  
14.2  
15.0  
165  
14.2  
15.0  
170  
¹
²
³
Natural Gas BTU/h  
DOE AFUE based upon Isolated Combusꢀon System (ICS)  
Installer must supply one or two PVC pipes: one for combusꢀon air (opꢀonal) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in  
diameter, depending upon furnace input, number of elbows, length of run and installaꢀon (1 or 2 pipes). The opꢀonal Combusꢀon Air Pipe is dependent  
on installaꢀon/code requirements and must be 2” or 3” diameter PVC.  
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with Naꢀonal Electrical  
Codes. Extensive wire runs will require larger wire sizes.  
Maximum Overcurrent Protecꢀon Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of  
the same size as noted.  
Notes  
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.  
Gas Service Connecꢀon ½” FPT  
Important: Size fuses and wires properly and make electrical connecꢀons in accordance with the Naꢀonal Electrical Code and/or all exisꢀng local codes.  
SS-GMVM96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
PRoDucT sPeciFicATions  
gMVM96 DiMensions  
28¾  
¾
¾
¾
2½  
19⅞  
2¹/₁₁  
2¹¹/₁₁  
7⅜  
4⅛  
1¾  
30¼  
6⅛  
24₁/₁₁  
27⅛  
1½  
2⅝  
19³/₁₁  
2⅝  
21¼  
30¼  
19³/₁₁  
11¾  
1¾  
16⅝  
32¹³/₁₁  
11¾  
1¾  
22 ¹/₁₁  
FOLDED FLANGES  
1⅝  
FOLDED FLANGES  
D
23 /₆  
UNFOLDED FLANGES  
UNFOLDED FLANGES  
E
RIGHT SIDE VIEW  
FRONT VIEW  
LEFT SIDE VIEW  
Model  
W
D
H
A
B
C
D
E
GMVM960603BX  
GMVM960805CX  
GMVM961005DX  
GMVM961155DX  
17½”  
21"  
28¾"  
28¾"  
28¾"  
28¾"  
40¾"  
40¾"  
40¾"  
40¾"  
17½”  
21"  
16"  
13⅛"  
16⅛"  
20⅝"  
20⅝"  
12⅛"  
16"  
13⅝"  
17½”  
20⅞"  
20⅞"  
19½”  
23"  
24½”  
24½”  
24½”  
24½”  
19⅜"  
19⅜"  
23"  
Notes:  
Installer must supply one or two PVC pipes: one for combusꢀon air (opꢀonal) and one for the flue outlet (required). Vent pipe must be either 2” or 3”  
in diameter, depending upon furnace input, number of elbows, length of run and installaꢀon  
(1 or 2 pipes). The opꢀonal Combusꢀon Air Pipe is dependent on installaꢀon/code requirements and must be 2” or 3” diameter PVC.  
Line voltage wiring can enter through the right or leſt side of the furnace. Low-voltage wiring can enter through the right or leſt side of furnace.  
Conversion kits for high-alꢀtude natural gas operaꢀon are available. Contact your Goodman distributor or dealer for details.  
Installer must supply following gas line ꢁꢂngs, according to which entrance is used:  
Leſt—Two 90º elbows, one close nipple, straight pipe  
Right—Straight pipe to reach gas valve  
For boꢃom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.  
MiniMuM cleARAnces To coMbusTible MATeRiAls  
Position  
Upflow  
Sides  
0”  
Rear  
0”  
Front  
3”  
Bottom  
Flue  
0”  
Top  
1”  
C
C
Horizontal  
6”  
0”  
3”  
0”  
6”  
C = If placed on combusꢀble floor, the floor MUST be wood ONLY.  
Notes  
For servicing or cleaning, a 24” front clearance is required.  
Unit connecꢀons (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.  
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GMVM96  
PRoDucT sPeciFicATions  
gcVM96 DiMensions  
FOLDED FLANGES  
FOLDED FLANGES  
UNFOLDED FLANGES  
UNFOLDED FLANGES  
Model  
GCVM960604CX  
GCVM960805DX  
GCVM961005DX  
Notes:  
W
D
H
A
B
C
D
E
21"  
28¾"  
28¾"  
28¾"  
40¾"  
40¾"  
40¾"  
21"  
19½”  
23"  
23"  
16⅛"  
20⅝"  
20⅝"  
18"  
19½”  
23"  
23"  
24½”  
24½”  
24½”  
24½”  
21½”  
21½”  
Installer must supply one or two PVC pipes: one for combusꢀon air (opꢀonal) and one for the flue outlet (required). Vent pipe must be either 2” or  
3” in diameter, depending upon furnace input, number of elbows, length of run, and installaꢀon (1 or 2 pipes). The opꢀonal Combusꢀon Air Pipe is  
dependent on installaꢀon/code requirements and must be 2” or 3” diameter PVC.  
Line voltage wiring can enter through the right or leſt side of the furnace. Low-voltage wiring can enter through the right or leſt side of furnace.  
Conversion kits for high-alꢀtude natural gas operaꢀon are available. Contact your Goodman distributor or dealer for details.  
Installer must supply following gas line ꢁꢂngs, according to which entrance is used:  
Leſt—Two 90º elbows, one close nipple, straight pipe  
Right—Straight pipe to reach gas valve  
For boꢃom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.  
MiniMuM cleARAnces To coMbusTible MATeRiAls  
Position  
Downflow  
Horizontal  
Sides  
0”  
Rear  
0”  
Front  
3”  
Bottom  
Flue  
0”  
Top  
1”  
NC  
C
6”  
0”  
3”  
0”  
6”  
C = If placed on combusꢀble floor, the floor MUST be wood ONLY.  
NC = For installaꢀon on non-combusꢀble floors only. A combusꢀble floor sub-base must be used for installaꢀons on combusꢀble flooring.  
Notes  
For servicing or cleaning, a 24” front clearance is required.  
Unit connecꢀons (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.  
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.  
SS-GMVM96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
PRoDucT sPeciFicATions  
gMVM96 AiRFlow DATA — cooling sPeeDs  
GMVM960603BX  
GVMV960805CX  
High Stage  
Adjust  
Low Stage  
Adjust  
High Stage  
Adjust  
Low Stage  
Adjust  
Tap  
CFM*  
567  
Tap  
CFM*  
351  
390  
429  
495  
550  
605  
612  
680  
748  
720  
800  
880  
Tap  
CFM*  
Tap  
CFM*  
486  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
747  
830  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
A
630  
A
A
A
540  
693  
913  
594  
720  
981  
675  
B
C
D
800  
B
C
D
B
C
D
1090  
1199  
1314  
1460  
1606  
1620  
1800  
1980  
B
C
D
750  
880  
825  
900  
882  
1000  
1100  
1089  
1210  
1331  
980  
1078  
1089  
1210  
1331  
*
@ .1" - .8" w.c. ESP  
*
@ .1" - .8" w.c. ESP  
GMVM961005DX  
GMVM961155DX  
High Stage  
Low Stage  
Adjust  
High Stage  
Low Stage  
Adjust  
Tap  
Adjust  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
CFM*  
711  
Tap  
CFM*  
459  
Tap  
Adjust  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
CFM*  
711  
Tap  
CFM*  
459  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
A
790  
A
510  
A
790  
A
510  
869  
561  
869  
561  
990  
639  
990  
639  
B
C
D
1100  
1210  
1269  
1410  
1551  
1647  
1830  
2013  
B
C
D
710  
B
C
D
1100  
1210  
1269  
1410  
1551  
1647  
1830  
2013  
B
C
D
710  
781  
781  
819  
819  
910  
910  
1001  
1044  
1160  
1276  
1001  
1044  
1160  
1276  
*
@ .1" - .8" w.c. ESP  
Notes:  
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.  
For most jobs, about 400 CFM per ton when cooling is desirable.  
Operaꢀon is recommended below .5” w.c. ESP in heaꢀng mode. Operaꢀng CFM between .5” and .8” w.c. is tabulated for cooling purposes only.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GMVM96  
PRoDucT sPeciFicATions  
gMVM96 AiRFlow DATA — HeATing sPeeDs  
GMVM960603BX  
(Rise Range: 20 - 50°F)  
GMVM960805CX  
Rise Range: 35 - 65°F)  
Adjust  
Tap  
Adjust  
Tap  
CFM *  
Rise (°F)  
CFM *  
Rise (°F)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
855  
950  
62  
56  
51  
56  
51  
46  
50  
45  
41  
46  
42  
38  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
1,440  
1,600  
1,760  
1,521  
1,690  
1,859  
1,620  
1,800  
1,980  
1,701  
1,890  
2,079  
49  
44  
40  
47  
42  
38  
44  
39  
36  
42  
37  
34  
1,045  
945  
1,050  
1,155  
1,053  
1,170  
1,287  
1,143  
1,270  
1,397  
* @ .1" - .5" w.c. ESP  
* @ .1" - .5" w.c. ESP  
GMVM961005DX  
(Rise Range: 35 - 65°F)  
GMVM961155DX  
(Rise Range: 35 - 65°F)  
Adjust  
Tap  
Adjust  
Tap  
CFM *  
Rise (°F)  
CFM *  
Rise (°F)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
1,629  
1,810  
1,991  
1,665  
1,850  
2,035  
1,701  
1,890  
2,079  
1,746  
1,940  
2,134  
54  
49  
44  
53  
48  
43  
52  
47  
43  
51  
46  
41  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
1,629  
1,810  
1,991  
1,665  
1,850  
2,035  
1,701  
1,890  
2,079  
1,746  
1,940  
2,134  
62  
56  
51  
60  
54  
49  
59  
53  
48  
58  
52  
47  
* @ .1" - .5" w.c. ESP  
Notes  
* @ .1" - .5" w.c. ESP  
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.  
For most jobs, about 400 CFM per ton when cooling is desirable.  
Operaꢀon is recommended below .5” w.c. ESP in heaꢀng mode. Operaꢀng CFM between .5” and .8” w.c. is tabulated for  
cooling purposes only.  
100% CFM shown. CFM will vary proporꢀonally with the gas valve BTU/H input.  
SS-GMVM96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
PRoDucT sPeciFicATions  
gcVM96 AiRFlow DATA — cooling sPeeDs  
GCVM960604CX  
GCVM960805DX  
High- or Single Stage  
Cooling Adjust  
Low Stage  
High- or Single Stage  
Cooling Adjust  
Low Stage  
Cooling Adjust  
Cooling Adjust  
CFM *  
CFM *  
CFM *  
CFM *  
Speed Tap  
Tap  
Speed Tap  
Tap  
Speed Tap  
Tap  
Speed Tap  
Tap  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
594  
660  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
333  
370  
407  
486  
540  
594  
711  
790  
869  
882  
980  
1078  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
810  
900  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
477  
530  
A
A
A
A
726  
990  
583  
774  
990  
657  
B
C
D
860  
B
C
D
B
C
D
1100  
1210  
1287  
1430  
1573  
1692  
1880  
2068  
B
C
D
730  
946  
803  
1035  
1150  
1265  
1323  
1470  
1617  
837  
930  
1023  
1098  
1220  
1342  
*
@ .1” - .8” w.c. ESP  
Notes  
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.  
For most jobs, about 400 CFM per ton when cooling is desirable.  
Operaꢀon is recommended below .5” w.c. ESP in heaꢀng mode. Operaꢀng CFM between .5” and .8” w.c. is tabulated for cooling purposes only.  
GCVM961005DX  
High- or Single Stage  
Cooling Adjust  
Low Stage  
Cooling Adjust  
CFM *  
CFM *  
Speed Tap  
Tap  
Speed Tap  
Tap  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
702  
780  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
450  
500  
A
B
C
D
A
858  
550  
963  
666  
1070  
1177  
1242  
1380  
1518  
1602  
1780  
1958  
B
C
D
740  
814  
828  
920  
1012  
1044  
1160  
1276  
*
@ .1” - .8” w.c. ESP  
Notes  
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.  
For most jobs, about 400 CFM per ton when cooling is desirable.  
Operaꢀon is recommended below .5” w.c. ESP in heaꢀng mode. Operaꢀng CFM between .5” and .8” w.c. is tabulated for cooling purposes only.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GMVM96  
PRoDucT sPeciFicATions  
gcVM96 AiRFlow DATA — HeATing sPeeDs  
GCVM960604CX  
ACVM960604CX  
Rise Range: 20 - 50°F)  
GCVM960805DX  
ACVM960805DX  
Rise Range: 20 - 50°F)  
Adjust  
Tap  
Adjust  
Tap  
CFM *  
Rise (°F)  
CFM *  
Rise (°F)  
Minus(-)  
Normal  
1,098  
1,220  
1,342  
1,206  
1,340  
1,474  
1,314  
1,460  
1,606  
1,431  
1,590  
1,749  
48  
44  
40  
44  
40  
36  
40  
36  
33  
37  
33  
30  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
1,440  
1,600  
1,760  
1,539  
1,710  
1,881  
1,620  
1,800  
1,980  
1,719  
1,910  
2,101  
49  
44  
40  
46  
41  
38  
44  
39  
36  
41  
37  
34  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
*
@ .1" - .5" w.c. ESP  
*
@ .1" - .5" w.c. ESP  
GCVM961005DX  
Rise Range: 25 - 55°F)  
Adjust  
Tap  
CFM *  
Rise (°F)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
Minus(-)  
Normal  
Plus (+)  
1,557  
1,730  
1,903  
1,593  
1,770  
1,947  
1,656  
1,840  
2,024  
1,683  
1,870  
2,057  
56  
51  
46  
55  
49  
45  
53  
48  
43  
52  
47  
43  
*
@ .1" - .5" w.c. ESP  
Notes  
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.  
For most jobs, about 400 CFM per ton when cooling is desirable.  
Operaꢀon is recommended below .5” w.c. ESP in heaꢀng mode. Operaꢀng CFM between .5” and .8” w.c. is tabulated for  
cooling purposes only.  
100% CFM shown. CFM will vary proporꢀonally with the gas valve BTU/H input.  
SS-GMVM96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
PRoDucT sPeciFicATions  
TeMPeRATuRe Rise RAnge cHART  
E S I R E R U T A R E P M E T  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GMVM96  
PRoDucT sPeciFicATions  
wiRing DiAgRAM  
TO  
GND  
24V  
HUM.  
115 VAC/1 Ø /60  
HZ  
POWER SUPPLY WITH  
OVERCURRENT  
PROTECTION  
ID BLOWER TWO-STAGE PRESSURE  
SWITCH ASSEMBLY  
HOT  
DEVICE  
L
BR  
SURFACE  
IGNITER  
WARNING:DISCONNECT  
POWER BEFORE  
SERVICING WIRING.  
TO UNIT MUST BE  
PROPERLY POLARIZED  
AND GROUNDED.  
BK  
HIGH FIRE  
PRESSURE  
SWITCH  
OR  
N
LOW FIRE  
WH  
C
C
PRESSURE  
SWITCH  
DISCONNECT  
NO  
NO  
YL  
2 CIRCUIT  
2
1
CONNECTOR  
TO 115VAC/1  
Ø /60 HZ POWER SUPPLY WITH  
OVERCURRENT PROTECTION DEVICE  
OR  
GND  
L
N
MODULATING  
GAS VALVE  
(HONEY WELL)  
WARNING:  
2
1
BR  
C
FLAME  
DISCONNECT POWER  
BEFORE SERVICING  
WIRING TO UNIT  
MUST BE PROPERLY  
POLARIZED AND  
GROUNDED.  
C
SENSOR  
GY  
PM  
GY  
FRONT COVER  
PRESSURE SWITCH  
NO  
DISCONNECT  
MANUAL RESET ROLLOUT LIMIT CONTROLS  
(SINGLE CONTROL ON 45 kBTU)  
PU  
PK  
DOOR  
SWITCH  
JUNCTION BOX  
OR  
AUTO RESET PRIMARY  
LIMIT CONTROL  
INDUCTOR COIL  
70kBTU,90kBTU,  
115kBTU MODELS  
ONLY  
OR  
PU  
INDOOR  
AIR  
INDUCED  
DRAFT  
3
2
1
WH  
RD  
BK  
CIRCULATOR  
BLWR  
BLOWER  
GND  
LINE  
EAC  
NEUTRAL  
NEUTRAL  
GND  
BURNER COMPARTMENT  
BLOWER COMPARTMENT  
ELECTRONIC  
AIR CLEANER  
PU  
AUTO RESET  
AUXILIARY  
LIMIT CONTROL  
OPTIONAL  
3
YL  
2
1
3Ø ID  
BLWR  
HUM  
IGN  
NEUTRAL  
NEUTRAL  
HUMIDIFIER  
OPTIONAL  
1
2
3
HOT SURFACE  
IGNITER  
FS  
FLAME  
SENSOR  
115  
VAC  
NEUTRAL  
LINE  
DIAGNOSTIC  
LED'S  
HSI  
EAC  
40 VA  
FUSE 3A  
TR (5)  
TRANSFORMER  
R
24 VAC  
AUTO RESET PRIMARY  
AUTO RESET AUXILIARY LIMIT  
CONTROLS  
LIMIT CONTROL  
TO +VDC  
(3)  
(6)  
Y1  
LOW FIRE PRESS.  
SWITCH  
C
24  
VAC  
W1  
W2  
(12)  
115  
VAC  
NO  
NO  
(2)  
TO  
MICRO  
C
HIGH FIRE  
Y2  
G
MANUAL RESET ROLLOUT  
LIMIT CONTROLS  
PRESS. SWITCH  
(11)  
WH  
O
FUSE  
DEHUM  
24 V THERMOSTAT CONNECTIONS  
AUX  
(8)  
NO  
24 V 3A  
PM  
FRONT COVER  
PRESS. SWITCH  
C
(7)  
C
C
ECM MTR  
HARNESS  
(10)  
GAS  
VALVE  
BK  
BL  
GY  
GND (4)  
TR (9)  
GND (4)  
RD  
WH  
GND  
BK  
TO  
R
5
BK  
WH  
GR  
+ VDC (1)  
4
3
2
1
INDOOR  
AIR  
CIRCULATOR  
BLWR  
RX (2)  
TX (3)  
GND  
PK  
TO  
MICRO  
BLOWER  
COMPARTMENT  
DOOR SWITCH  
(OPEN WHEN  
DOOR OPEN)  
INTEGRATED CONTROL  
MODULE  
CIRCULATOR BLOWER  
INDUCTOR COIL  
70kBTU,90kBTU,  
115kBTU MODELS  
ONLY  
HUMIDIFIER  
OPTIONAL  
NOTES:  
COLOR CODES:  
EQUIPMENT GND  
FIELD GND  
LOW VOLTAGE FIELD  
PK PINK  
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.  
LOW VOLTAGE (24V)  
HI VOLTAGE (115V)  
HI VOLTAGE FIELD  
BR BROWN  
WH WHITE  
BL BLUE  
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE  
USED WHEN SERVICING.  
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE  
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH  
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT  
LEAST 105°C. USE COPPER CONDUCTORS ONLY.  
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO  
N.E.C. AND LOCAL CODES.  
FIELD SPLICE  
SWITCH (TEMP)  
IGNITER  
GY GRAY  
RD RED  
JUNCTION  
TERMINAL  
YL YELLOW  
OR ORANGE  
PU PURPLE  
GR GREEN  
BK BLACK  
5. TO RECALL THE LAST 10 FAULTS, MOST RECENT TO LEAST  
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE  
IN STANDBY (NO THERMOSTAT INPUTS)  
SWITCH PRESSURE  
INTERNAL TO  
INTEGRATED CONTROL  
OVERCURRENT  
PROT. DEVICE  
PLUG CONNECTION  
0140F00863-B  
SS-GMVM96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
PRoDucT sPeciFicATions  
AccessoRies  
GCVM96 GCVM96 GCVM96  
GMVM96 GMVM96 GMVM96 GMVM96  
Model  
Description  
0604CX  
0805DX  
1005DX  
0603BX  
0805CX  
1005DX  
1155DX  
LPKM0D060UF  
LPKM0D080UF  
LPKM0D100UF  
LPKM0D115UF  
LPKM0D060CF  
LPKM0D080CF  
LPKM0D100CF  
EFR01  
LP Conversion Kits  
External Filter Rack  
---  
---  
DCVK-20  
Horizontal/Verꢀcal Concentric Vent Kit (2”)  
Horizontal/Verꢀcal Concentric Vent Kit (3”)  
Downflow Floor Base  
---  
DCVK-30  
CFB21  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
CFB24  
Downflow Floor Base  
---  
017K00000S  
Flush-mount vent kit  
Notes  
Indicates available for this model  
For installaꢀon in Canada, gas furnaces are cerꢀꢁed only to 4,500.  
THeRMosTATs  
GTS1175-2  
GTS3275-2  
GTS 4275-2  
Touch-Screen Digital Thermostats  
(See Amana Thermostat specification sheets for details.)  
G2111-2  
G3272-2  
G3273-2  
Touch-Screen Digital Thermostats  
(See Amana Thermostat specification sheets for details.)  
G1100-2  
G2100-2  
G1152-2  
G2152-2  
Programmable and Non-programmable Digital Thermostats  
(See Amana Thermostat specification sheets for details.)  
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without  
notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. Houston, Texas • Printed in the USA.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GMVM96  

ETA Systems Power Supply PD11LP User Manual
ETI Sound Systems INC Stereo Amplifier AT 212 User Manual
Everpure Water System DEV9108 25 User Manual
Extron electronic Network Card RGB HDMI 300 User Manual
Fisher Price Baby Toy G5136 User Manual
Fisher Price Telescope G2579 User Manual
Furuno Telephone FM 8800D 8800S User Manual
Gateway Computer Monitor FPD1785 User Manual
Gemini CD Player CD 9800 User Manual
Gitzo Camcorder Accessories G1297 User Manual