GarrettCom Switch DS50 User Manual

Magnum DS50 / DS60s  
Dual Speed Hubs Plus  
Installation and User Guide  
www  
.
GarrettCom . com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Contacting GarrettCom, Inc  
Please use the mailing address, phone and fax numbers and email address listed below:  
GarrettCom, Inc.  
47823 Westinghouse Dr..  
Fremont, CA 94539  
Phone (510) 438-9071  
Fax (510) 438-9072  
Federal Communications Commission  
Radio Frequency Interference Statement  
Warning: Changes or modifications to this unit not expressly approved by the party  
responsible for compliance could void the user’s authority to operate the equipment.  
NOTE: This equipment has been tested and found to comply with the limits for a class  
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful interference in a residential  
installation. This equipment generates, uses, and can radiate radio frequency energy  
and, if not installed and used in accordance with the instructions, may cause harmful  
interference in a residential installation. This equipment generates, uses, and can  
radiate frequency energy and, if not installed and used in accordance with the  
instructions, may cause harmful interfernce to radio communications. However, there  
is no guarantee that interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this equipment  
does cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try to  
correct the interference by one or more of the following measures.  
-
-
-
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into n outlet on a ccircuit different from that to  
which the receiver is connected.  
-
Consult the dealer or an experienced radio TV technician for help.  
Canadian Emission  
This Class B digital apparatus meets all requirements of the Canadian  
Interference-Causing Equipment Regulations.  
Cet appareil respecte toutes les exigences du Réglement sur le matériel du  
Canada. Cet appareil est Classe B.  
TABLE OF CONTENTS  
www GarrettCom  
PAGE  
.
.
com  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
1.0 SPECIFICATIONS.........................................................................................................................2  
1.1 Technical Specifications..............................................................................................................2  
1.2 Ordering Information .................................................................................................................4  
2.0 INTRODUCTION...........................................................................................................................5  
2.1 Inspecting the Package and Product .........................................................................................5  
2.2 Product Description....................................................................................................................6  
2.2.1 Magnum DS60F DS Hubs Plus, with Fiber Switched Port...........................................7  
2.2.2 Fiber port, SC Connector for Model DS60F ..................................................................8  
2.2.3 Magnum DS60C DS Hubs Plus with Copper port, Chassis .........................................8  
2.2.4 Port #6: Switched 10/100 Mb/s Port for DS60C only....................................................9  
2.2.5 Magnum DS50 Dual-speed Hubs Chassis.......................................................................9  
2.2.6 Ports 1-5: 10/100 Mb/s Shared Ports for DS50 / DS60................................................10  
2.2.7 10 / 100 Speed Auto-sensing...........................................................................................10  
2.2.8 Bridge logic between the 10 Mbps and 100Mbps Domains ........................................11  
2.2.9 Up-link Switch for Cascading........................................................................................11  
2.3 Frame Buffering and Latency..................................................................................................12  
2.4 Features and Benefits................................................................................................................14  
2.5 Applications................................................................................................................................15  
3.0 INSTALLATION..........................................................................................................................18  
3.1 Locating the Magnum DS50 / DS60 Dual-speed Hubs Plus..................................................18  
3.1.1 Table-Top or Shelf Mounting ........................................................................................18  
3.1.2 Optional mounting methods, DIN-rail and E-Stand ...................................................19  
3.2 Ethernet Media, connections and Specifications....................................................................19  
3.2.2 Connecting Fiber Optic SC-type, "Snap-In"...............................................................20  
3.2.3 Connecting Single-Mode Fiber Optic............................................................................21  
3.2.4 Power Budget Calculations for DS60F Fiber Media...................................................21  
3.2.5 Connection to NICs which support Auto-Neg, RJ-45 ports .......................................22  
3.2.6 Collision Domain Diameter............................................................................................22  
3.3 Powering the Magnum DS50 / DS60 .......................................................................................25  
4.0 OPERATION.................................................................................................................................26  
4.1 Dual-Speed Functionality .........................................................................................................26  
4.2 Auto-negotiation and speed-sensing ........................................................................................28  
4.3 Switching Functionality for port # 6 (DS60s Only)................................................................28  
4.4 LEDs ...........................................................................................................................................29  
4.5 (FF-A) Manual Switch, Port 6 for DS60C ..............................................................................29  
4.6 (F-H) Manual Switch, Port 6 for DS60F .................................................................................30  
4.7 Up-link Switch, Port 1..............................................................................................................30  
5.0 TROUBLESHOOTING ...............................................................................................................31  
5.1 Before Calling for Assistance ...................................................................................................31  
5.2 When Calling for Assistance ....................................................................................................32  
5.3 Return Material Authorization (RMA) Procedure................................................................32  
5.4 Shipping and Packaging Information .....................................................................................33  
APPENDIX A: WARRANTY INFORMATION ........................................................................33  
APPENDIX B : Optional 24VDC or -48VDC Power Supply ....................................................34  
REVISIONS  
Rev D 06/02: Add 24VDC power option in Appendix B  
Rev C 11/01: Change the company name to GarrettCom, Inc. (Formerly it was Garrett  
Communications). Add Fiber models to DS60s, add DIN-rail mounting option.  
Rev B 09/01: Addition of warnings in French language. Fiber information added.  
Rev A 08/01: This is the initial release of the DS50 / DS60 hub user manual.  
www  
.
GarrettCom  
.
com  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 & DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
The Magnum Line  
ETHERNET C ONNEC TIVITY PRODUC TS  
"DESIG NED AND MANUFAC TURED IN THE USA"  
OVERVIEW  
GarrettCom offers the Magnum line of Ethernet LAN connectivity products with  
industry-standard functionality. Magnum products are available worldwide  
through OEMs, integrators, representatives, retailers and international  
distributors.  
6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-  
and match. Features SFF fiber for up to 25 fiber ports in a 1U unit.  
4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-  
negotiating full switching performance.  
Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and  
mixed-media types, full switching performance.  
“Outdoor” Ethernet Switch, for temperature uncontrolled locations  
6 10/100 and 2 100Mb fiber ports, can be connected in strings  
Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing  
Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing  
Stackable Hubs, SNMP Optional  
10Mb series and 100Mb series, both w/ optional port modules  
Personal Switches, 10/100Mb  
8 port dual speed, Auto-negotiable with fiber option  
Personal Hubs, 100Mb or 10/100Mb  
8-port, with two switched ports (1 fiber built in)  
Personal Hubs, 10Mb series  
8-port + AUI, stackable to 5 high, + optional BNC of fiber port  
8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.  
Media Converters, 10Mb and 100Mb series  
All media combinations, incl. fiber ST, SC, mm., single mode  
The “X-line” of configurable MiXed Media products:  
Stackable Concentrators, SNMP optional, 13-Ports  
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports  
Repeater Port Modules (RPMs), 6 types for Ethernet media  
Bridge Port Modules (BPMs), 4 types, for segment isolation  
Transceivers, 10Mb series Mini-Transceivers and Coax Models  
June, 02  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
1.0  
SPECIFICATIONS  
1.1  
Technical Specifications  
Performance  
Port 1-5: Repeater Ports, with bridge between  
Data Rate: 10/100 Mbps (Dual-Speed)  
PDV (Path Delay Value): 80BT  
Port 6: Switched Port (DS60C only)  
10/100Mbps (Dual-Speed)  
When set to “FF”:  
Data Rate: 100 Mbps Full Duplex  
PDV (Path Delay Value): 50BT (end node)  
When set to “A”  
Date Rate: 10Mbps or 100Mbps (Depends upon the connected  
speed on the other side; if the connected unit supports auto-  
negotiate then run on full-duplex otherwise half-duplex)  
Packet Processing on Switched Port, port 6  
Processing type: Store and Forward  
Filtering and Forwarding Rate: Switch = “10”, 14,880 pps max.  
Switch = “100”, 148,800 pps max  
Auto-learning: 8K addresses  
Packet buffers: 1MB dynamically allocated  
Latency (not including packet time): 5µs  
Packet Processing on Repeater Port, ports #1-5 bridged  
Processing type: advertising and sharing  
Auto-learning: 2K addresses  
Packet buffers: 256 dynamically allocated and shared on ports #1-5  
Latency (not including packet time): 5µs  
Maximum Ethernet Segment Lengths  
10BASE-T (unshielded twisted pair, 10Mb) - 100 m (328 ft)  
100BASE-TX (Cat. 5 twisted pair, 100Mb) - 100 m (328 ft)  
100BASE-FX, half-duplex: (multi-mode)  
100BASE-FX, full-duplex: (multi-mode)  
- 412 m (1350 ft)  
- 2.0 km (6,562 ft)  
100BASE-FX, half-duplex: (single-mode) - 412 m (1350 ft)  
100BASE-FX, full-duplex: (single-mode) - 20.0 km (65,620 ft)  
100BASE-FX, full-duplex: (single-mode, long)- 40.0 km (131,240 ft)  
Network Standards  
Ethernet IEEE 802.3u: 100BASE-TX  
IEEE 802.3: 10BASE-T  
Operating Environment  
Ambient Temperature: 32ºF to 122ºF (0ºC to 55ºC)  
Storage Temperature: -5ºF to 160ºF (-20ºC to 70ºC)  
Ambient Relative Humidity: 5 % to 95 % (non-condensing)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Power Supply (Internal) AC  
AC Power connector: IEC-type, male recessed, rear of chassis  
Power Input Voltage: 100 to 240 VAC (auto-ranging)  
Power Input Frequency: 47-63 Hz  
Power Consumption: typical 6 watts, 10 watts max.  
Power Supply (Internal), Optional 24VDC and -48VDC  
-48VDC Power Input Voltage : 36 to 72 VDC  
24VDC Power Input Voltage : 20 to 36VDC  
Std. Terminal Block : “ -, GND, + ”  
Power Consumption: same as for AC models, see above  
DC-DC Converter Rating: 5VDC, 2Amps  
Manual Switches  
Port 1 only, UP-LINK: MDI-X thumb-operated slide switch, converts RJ-45  
port from a regular (= position) user segment port to a crossover (X position)  
Port 6 only (DS60C): Thumb-operated slide switch FF-A, The port #6 switched  
port can be set on “FF” (Full-duplex, Fixed 100Mbps) or at “A”(Auto-  
negotiation) to support auto-negotiate.  
Port 6 only (DS60F): Thumb-operated slide switch FDX-HDX, The port #6  
switched Fiber port can be set on “Fdx” (Full-duplex, Fixed 100Mbps) or at  
Hdx (Half Duplex) to provide better secure distance.  
Packaging  
Enclosure: High strength sheet metal.  
Suitable for wiring closet shelf, wall or desktop mounting.  
Dimensions: 9.1 in. D x 6.1 in. W x 1.3 in. H (23.0 cm x 15.5 cm x 3.3 cm)  
Weight: 1.55 lb. (0.7 Kg)  
Cooling method: Fan cooled, internal @ 7 cfm  
LED Indicators on Chassis  
PWR : Steady On when power applied  
COL 100 (port1-5): Collision, flashing when collision occurs on  
ports 1-5 in the 100Mb collision domain.  
COL 10 (port1-5): Collision, flashing when collision occurs on  
ports 1-5 in the 10 Mb collision domain.  
LK/RX (port 1-5): Steady On when twisted-pair link is operational,  
flashing when port is receiving data  
100 (port 6): Speed is at 100Mbps  
FDX (port 6): Port is at Full duplex  
Agency Approvals (Under Test)  
UL Listed (UL 1950), cUL, CE  
Emissions: meets FCC Part 15, Class A  
Warranty  
Three years, return to factory  
Made in USA  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
1.2  
Ordering Information  
Magnum DS50 / DS60 Dual-speed Hubs Plus  
Models  
Magnum DS60C  
Six dual speed ports, five 10/100 Dual-speed shared “hub”  
ports plus one 10/100 switched port, with shielded RJ-45  
connectors and front-mounted LED’s. The port #6 switched  
port is a separate collision domain with wire-speed (10/100)  
filtering and forwarding of traffic, 1Mb dynamically allocated  
packet buffers and 8K-entry self-learning address table. The  
selection of Full Fixed and Auto-negotiation for port #6 can  
be set through manual switch. Internal universal power  
supply, up-link switch or port #1. Optionally available with  
24VDC and -48VDC internal power supply.  
Magnum DS60F-MSC  
Same as DS60C except 6th port is switched  
fiber port, multi-mode SC, can be set as Full duplex (by  
default) or Half-duplex by manual switch underneath.  
Magnum DS60F-SSC  
Same as DS60C except 6th port is switched  
fiber port, single-mode SC, supports 20Km distance  
Magnum DS60F-SSC  
Same as DS60C except 6th port is switched  
fiber port, single-mode SC, Long reach 40Km distance  
Magnum DS50  
Same as Magnum DS60C, but without the switched port # 6,  
has only the 5 repeater ports with dual speed (10/100)  
capability.  
MST Conversion  
Special order item, convert fiber SC port to ST-type connector.  
GarrettCom reserves the right to change specifications, performance  
characteristics, and/or model offerings without notice.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
2.0  
INTRODUCTION  
2.1  
Inspecting the Package and Product  
Examine the shipping container for obvious damage prior to installing this product;  
notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect  
the contents of this package for any signs of damage and ensure that the items listed below are  
included.  
This package should contain:  
1
1
2
2
1
1
Magnum DS50 or DS60s Dual-speed Hub Plus unit  
AC Power Cord (U.S. and other 115 vac locations only)  
Metal mounting brackets for optional vertical mounting  
Mounting screws for use with the metal mounting brackets  
Installation and User Guide  
Product Registration Card  
Remove the Magnum DS50 / DS60 Dual-speed Hub Plus from the shipping  
container. Be sure to keep the shipping container should you need to ship the unit at a later  
date. To validate the product warranty, please complete and return the enclosed Product  
Registration Card to GarrettCom as soon as possible.  
In the event there are items missing or damaged, contact your supplier. If you need  
to return the unit, use the original shipping container. Refer to Chapter 5, Troubleshooting, for  
specific return procedures.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
2.2  
Product Description  
The Magnum DS60C Dual-speed Hub Plus is an easy to install, cost-effective Dual-  
speed hub. It has five 10/100Mb repeater shared ports along with a 10/100 Mbps switched port  
that can be configured to provide “auto-negotiating” or “Full fixed” connectivity between a  
100Mb segment and a 10Mb segment; or between two 100Mb segments at full duplex  
capability. The Magnum DS60F belongs to the same DS60’s family except the sixth port is a  
switched Fiber port at 100Mbps and can be set at Full-duplex or Half-duplex to support any  
connectivity with Hubs or switches. The “future-proof” fiber port provides a secure  
longer distance advantage and eliminates the need for a media converter,  
The Magnum DS50 dual-speed hub has only the five 10/100 Mb repeater ports. Each  
port can independently identify (via IEEE 802.3u auto sensing) and accept either 100Mbps or  
10Mbps Ethernet signals, adapting to match the best speed of the connected device. Each unit  
has its own internal power supply. The Magnum DS50 / DS60 Dual-speed Hub Plus has two  
internal traffic domains . . . one for the 100 Mb domain and one for the 10Mbps domain. The  
100Mbps users share the 100Mbps domain’s bandwidth and the 10 Mbps users share the  
10Mbps domain’s bandwidth.  
Magnum DS60  
Personal Hub Plus  
10Mbps Hub  
100Mbps Hub  
GARRETT  
RX  
PWR  
LINK  
100LINK  
100LINK  
10L0INK  
10L0INK  
100  
U
PLINK  
LK  
100  
FDX  
100  
10  
COL  
=
x
Magnum  
1
2
3
4
5
6
7
8
9
10 11 12  
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
2
3
4
5
PWR  
PWR  
6
Stackable  
8000E  
10/100  
M
b/s  
FF-A  
Hub  
G
GARRETT  
Fig. 2.2.1 Magnum DS50 / DS60 is functionally both a 10Mbps and 100Mbps in one  
The Magnum DS60s, because of their dual-speed capability and switched ports, are  
ideally suited for adding a Fast Ethernet workgroup to an existing 10Mb or 100Mb network. A  
small 10/100Mb workgroup connects to the five “hub” ports while another workgroup or an  
existing network segment . . . a separate collision domain of 10Mb or 100Mb units . . . connects  
to port 6. For expansion of the five 10/100Mb ports, an additional 100Mbps or 10Mb hub can  
be cascaded from port 1. Each domain can have its own local servers and other local traffic.  
Thus, the DS60s can bridge-isolate one collision domain from the other, separating the local  
traffic between each workgroup’s users and servers from the rest of the network. The Magnum  
DS60s will filter and forward the packets to / from port 6 and the other ports, thereby giving  
more bandwidth to each domain for maximum network performance.  
The Magnum DS50 / DS60s are available with an internal AC Power supply with  
auto-ranging power voltage (100 - 240 VAC). The 24VDC and -48VDC Power supply option  
enables this product to be used in the industrial and telecom markets. The Magnum DS50 /  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
DS60s are “plug and play” units enclosed in a lightweight, compact, rugged metal enclosure  
suitable for office, lab and industrial sites. The DS50 / DS60s are available for horizontal or  
vertical mounting (see Section 3.1).  
2.2.1  
Magnum DS60F Dual-speed Hubs Plus, with Fiber Switched Port  
The Magnum DS60F chassis houses one main board equipped with five  
hub ports and a switched fiber port. The switched fiber port is available with an SC connector  
and options of multi-mode,  
single-mode and long reach. It  
has an internal power supply and  
a small cooling fan in the bottom,  
extending ambient operation to  
55C. The port side of the chassis  
consists of five shared 10/100Mb  
RJ-45 ports and one 100Mb  
switched SC fiber port. There is  
an up-link (UPLINK) switch next  
to Port 1, which allows this port  
to be used for cascading to a hub  
or switch. There is a manual switch “F-H” underneath the switched port #6 which provides  
“Full-duplex” and “Half-duplex” capability to the switched port  
The Magnum DS60F has power (PWR) and collision (COL) LED’s and 10 and  
100 LEDs for the unit. It also has link (LINK) and receive (RX) activity LEDs for each of the  
five shared ports and for Port 6. The port #6 has a Full-duplex (FDX) and a speed (100) LED  
also. Rubber feet on the bottom provide a sturdy grip and clearance for the exhaust of the  
cooling fan.  
The internal power supply is an auto ranging AC power supply for input of 115-230  
vac, 50/60 Hz. Optionally available are 24VDC and -48VDC for the industrial and telecom  
markets. The recessed male IEC power connector is located at the right-rear. Two mounting  
brackets for optional wall mounting are supplied with each unit. An optional “edge- stand” is  
available (See “Spare Parts Price List”) and is used for floor-mounting on carpeted surfaces.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
2.2.2  
Fiber port, SC Connector for Model DS60F  
SC type (single-mode or multi-mode)  
The Fast Ethernet fiber  
switched port on the Magnum DS60F is  
set to operate at fixed 100Mb speed for  
guaranteed high performance. The  
DS60F’s fiber port is factory-built and  
available either as a multi-mode SC, or  
a single-mode or long-reach SC connector. The 100Mb fiber port will run at 100Mbs speed at  
all times with manually selected full- and half-duplex capability. The 100Mbps fiber port is a  
switched port and performs as a separate traffic domain, providing a high bandwidth backbone  
connection (no media converter is required !) and supporting long (up to 40km) fiber cable  
distances for installation versatility.  
Port 6 (the fiber port) has an “F - H” user-selectable manual switch. When set in the  
“F” position, it forces full-duplex mode. When set in the “H” position, it forces half-duplex  
mode, still at 100Mbps speed.  
On Magnum DS60F units, there are three LED’s for the switched ports. One (LK) is  
steady ON to indicate LINK is operational. The speed (100) LED is ON for 100Mbps and OFF  
for 10Mbps (when LINK is made). The F/H indicates full-duplex when ON. When it is OFF,  
operation is half-duplex.  
A fiber cable must be connected to the 100Mb port and a proper link (LK light) must be made  
with the device at the other end of the cable in order for these LEDs to provide valid indications  
of operating conditions.  
2.2.3  
Magnum DS60C Dual-speed Hubs Plus with Copper port, Chassis  
The Magnum DS60C chassis  
houses one main board for the five hub ports  
and for the switched port. It has an internal  
power supply and a small cooling fan in the  
bottom. The front side of chassis consists of  
Magnum  
Personal HDuSb60Plus  
GARRET  
T
RX  
LK  
PWR  
LINK  
100  
LINK  
100  
LINK  
100  
LINK  
100  
LINK  
100  
UPLINK  
100  
100  
FDX  
10  
=
x
COL  
1
3
4
5
2
6
FF-A  
10/100 Mb/s  
Magnum DS60C Dual-speed Hubs Plus  
www  
.
GarrettCom . com  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
five shared 10/100Mb RJ-45 ports and one “10/100Mb switched RJ-45 port. There is an up-link  
(UPLINK) switch for Port 1. There is a manual switch “FF-A” underneath the switched port #6  
that controls and provides “full-fixed” and “Auto-negotiation” capability to the port.  
2.2.4  
Port #6: Switched 10/100 Mb/s Port for DS60C only  
For Magnum DS60C  
Dual-speed Hub plus has Port 6 as a  
switched port located on the right  
front panel. Because of its dual  
speed and auto negotiation  
RX  
LK  
100  
FDX  
6
RX LED  
FF-A  
Link LED  
100 LED  
FDX  
Manual Switch  
FF-A  
capability, it operates either as a  
10BASE-T port or as a 100BASE-  
TX port. The speed may depend  
Figure 2.2.3: Port 6: Switched 10 or100Mb Port  
upon the attached unit’s speed. See section 4.3 for more details about the 10 or 100 switch.  
This switched port offers great flexibility in connecting the DS60C . . . as an  
additional 10/100Mb segment . . . to an existing 10 or 100Mb network. Because this port is  
segmented from the other DS60C ports, it provides a separate collision domain. Accordingly,  
the DS60C can be used as plug-and-play in practically any 10Mb or 100Mb network domain.  
The Magnum DS60C has power (PWR) and collision (COL) LED’s and 10 and 100  
LED’s for the unit. It also has link (LINK) and receive (RX) activity LED’s for each of the  
five shared ports and for Port 6. The port #6 has Full-duplex (FDX) and speed (100) LED’s too.  
Rubber feet on the bottom provide a sturdy grip and clearance for the exhaust of the cooling  
fan.  
The internal power supply is an auto ranging AC power input of 115-230 vac, 50/60  
Hz. The recessed male IEC power connector is located at the right-rear. Two mounting  
brackets for optional wall mounting are supplied with each unit. An optional “edge- stand” is  
available (See “Spare Parts Price List”) and is used for floor-mounting on carpeted surfaces.  
2.2.5  
Magnum DS50 Dual-speed Hubs Chassis  
The Magnum DS50 chassis houses one main board for the five dual-speed repeater  
ports. It has an internal power supply and a small cooling fan in the bottom. The front side of  
chassis consists of five shared 10/100Mb RJ-45 ports. There is an up-link (UPLINK) switch  
next to Port # 1, which it controls.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Magnum DS60  
Personal Hub Plus  
Magnum DS50 Dual-speed  
GARRE  
TT  
PWR  
LINK  
100  
LINK  
100  
LINK  
100  
LINK  
100  
LINK  
100  
UPLINK  
Hubs  
100  
10  
=
x
COL  
1
3
4
5
2
10/100 Mb/s  
The Magnum DS50 has a power (PWR) and collision (COL) LED’s and  
10 and 100 LED’s for the unit. It also has link (LINK) and receive (RX) activity LED’s for  
each of the five shared ports. Rubber feet on the bottom provide a sturdy grip and clearance for  
the exhaust of the cooling fan.  
The internal power supply is an auto ranging AC power input of 115-230 vac, 50/60  
Hz. The recessed male IEC power connector is located at the right-rear. Two mounting  
brackets for optional wall mounting are supplied with each unit. An optional “edge- stand” is  
available (See “Spare Parts Price List”) and is used for floor-mounting on carpeted surfaces.  
2.2.6  
Ports 1-5: 10/100 Mb/s Shared Ports for DS50 / DS60  
The Magnum  
100 LED  
Link LED  
Uplink Switch  
DS50 / DS60 Dual-speed  
Hubs has Ports 1-5 as shared  
10Mb / 100Mb ports. Each  
port has its own Link LED  
and an RX (receive) activity  
LED to indicate its status.  
These LED’s are built into  
the RJ-45 connector. The  
PWR  
LINK  
100  
LINK  
100  
LINK  
100  
LINK  
100  
LINK  
100  
Power LED  
Col. LED  
UPLINK  
100  
10  
=
x
COL  
1
3
4
5
2
10/100 Mb/s  
Figure 2.2.2 : Ports 1-5 : Shared 10/100Mb Ports  
Link LED will be on when proper cable connection is made on both ends and the RX LED will  
flash to indicate activity when the port is receiving data.  
The up-link switch for Port 1 is located on the left side and enables port 1 to either  
connect to a user station or to cascade with another hub or switch. See section 4.4 for more  
details about up-link.  
2.2.7  
10 / 100 Speed Auto-sensing  
The first five ports, # 1-5 RJ-45 twisted pair ports, support auto-sensing for speed and  
independent of the other ports. Speed-sensing is performed by the DS50 / DS60 electronics in  
accordance with the standards of the IEEE 802.3u auto-negotiation standard. If the connected  
www  
.
GarrettCom  
.
com  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
device or node indicates that it is capable of 100Mbps speed, then operation on that port will be  
at 100Mbps. If the connected device does not positively indicate that it is capable of 100Mbps  
speed, then the operation on that DS50 / DS60 port will be at 10Mbps. Of course, the hubs’  
auto-negotiation technique is only for 10/100 speed, and does not provide for any full-duplex  
operation.  
The per-port 10/100Mbps LK/RX LED’s on each repeater port indicate the result of  
auto-sensed speed detection, and the resulting connectivity to either a 10Mbps or 100Mbps  
device. The 100Mbps LED will illuminate (GREEN) when 100Mbps signals are detected; it  
will have a steady ON if there is no traffic and it will have a blinking ON when the port  
transmits and receives data packets. Similarly, for 10Mbps speed, it will be “off” when a  
10Mbps signal (or no reply to auto-negotiation) is detected, and it will blink if the linked port is  
transmitting and receiving.  
2.2.8  
Bridge logic between the 10 Mbps and 100Mbps Domains  
Bridge I.C.  
Figure 2.3 : Internal view of DS50  
with bridge logic  
Magnum DS50 / DS60’s contain bridge logic (in the Integrated Circuit) to interconnect the two  
traffic domains and filter and selectively forward packets to allow only necessary packets to  
cross between the domains. This enables all of the users and nodes connected into either  
domain, whether 100Mbps or 10Mbps, to communicate to each other. It also keeps local traffic  
on one domain from consuming any of the bandwidth from the other.  
The bridge operates in the store-and-forward mode, which filters out bad packets and  
maintains optimum performance in both domains. Packet forwarding delay is only 5µs (plus  
packet time). This is much less than traditional store-and-forward bridge products, enabling  
DS50 / DS60’s to maintain high network performance. The bridge has a 2K node address  
capacity, suitable for use in medium-sized networks. Addresses are self-learning so that  
filtering/forwarding of 10Mbps and 100Mbps packets is maintained correctly even when users  
move their connection, change speed, or power down.  
2.2.9  
Up-link Switch for Cascading  
The unit has an up-link switch located next to Port # 1 of the hub. It enables the port’s  
cable to cascade to another shared hub or switching hub port. (See Section 4.4 for more details  
about up-link). Port # 1 is a dual-speed port that will sense the speed of the connected device.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
The up-link operates the same, whether Port # 1 is connected to either a 100Mbps or 10Mbps  
device.  
When the up-link port is used to cascade two DS50 / DS60 hubs, the auto-sensing  
feature of the DS50 / DS60 will cause the connecting link to operate at 100Mbps speed.  
2.3  
Frame Buffering and Latency  
The Magnum DS60’s 6th port is a store-and-forward switch. Each frame (or packet)  
is loaded into the Switch’s memory and inspected before forwarding can occur. This technique  
ensures that all forwarded frames are of a valid length and have the correct CRC (i.e., are good  
packets). This eliminates the propagation of bad packets, enabling all of the available  
bandwidth to be used for valid information.  
While other switching technologies such as "cut-through" or "express" impose  
minimal frame latency, they will also permit bad frames to propagate out to the Ethernet  
segments connected. The "cut-through" technique permits collision fragment frames, which are  
a result of late collisions, to be forwarded to add to the network traffic. Since there is no way to  
filter frames with a bad CRC (the entire frame must be present in order for CRC to be  
calculated), the result of indiscriminate cut-through forwarding is greater traffic congestion,  
especially at peak activity. Since collisions and bad packets are more likely when traffic is  
heavy, the result of store-and-forward operation is that more bandwidth is available for good  
packets when the traffic load is greatest.  
To minimize the possibility of dropping frames on congested ports, Magnum DS60’s  
Switched port dynamically allocates buffer space from an 1MB memory pool, ensuring that  
heavily used ports receive very large buffer space for packet storage. (Many other switches  
have their packet buffer storage space divided evenly across all ports, resulting in a small, fixed  
number of packets to be stored per port. When the port buffer fills up, dropped packets result.)  
This dynamic buffer allocation provides the capability for the maximum resources to the  
DS60’s 6th port to be applied to all traffic loads, even when the traffic activity is unbalanced  
across the ports. Since the traffic on an operating network is constantly varying in packet  
density per port and in aggregate density, the Magnum DS60’s Switched 6th port is constantly  
adapting internally to provide maximum network performance with the least dropped packets.  
When the Switch detects that its free buffer queue space is low, the Switch sends  
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause  
“flow control”. This tells the sending devices to temporarily stop sending traffic, which allows  
a traffic catch-up to occur without dropping packets. Then, normal packet buffering and  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
processing resumes. This flow-control sequence occurs in a small fraction of a second and is  
transparent to an observer. See Section 4.6 for additional details.  
Another feature implemented in Magnum DS60’sSwitched port is a collision-based  
flow-control mechanism (when operating at half-duplex only). When the Switch detects that its  
free buffer queue space is low, the Switch prevents more frames from entering by forcing a  
collision signal on all receiving half-duplex ports in order to stop incoming traffic.  
The latency (the time the frame spends in the Switch before it is sent along or  
forwarded to its destination) of the DS60’s Switched port varies with the port-speed types, and  
the length of the frame is a variable here as it is with all store-and-forward switches. For 10  
Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15  
microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb forwarding, the latency is  
5 microseconds plus the packet time at 100Mb.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
2.4  
Features and Benefits  
Supports 10 or 100Mbps network connections on each of six RJ-45 ports  
A Magnum DS50 / DS60 Dual-Speed hub combines two logical hubs -- one at  
10Mbps and one at 100Mbps -- in one physical box supporting two traffic domains.  
Each port can operate at either 10 or 100Mbps, independently of the other ports.  
“ Future Proof” Fiber Switched port (for DS60F model only)  
The Magnum DS60F model, equipped with one Switched fiber port at 100Mb,  
enables it to provide secure longer cable distances, and eliminates the use of a media  
converter. The fiber port is available in SC multi-mode, single mode and Long reach.  
“Plug and Play” Installation and Operation  
The DS50 / DS60 Dual-speed Hub Plus learns the network addresses of  
both network segments from the packets in the traffic, so there is no software set-up  
required. As nodes are added or changed, the unit learns the new network addresses  
and adapts its filtering and forwarding of packets automatically.  
Segments 100Mb networks for high performance and simplified expansion  
The Magnum DS60’s (only) provides a separate collision domain which  
maximizes available bandwidth for both of the attached segments, enhancing network  
performance. The segmentation of the switched port 6 also resets cable distance  
limitations and repeater hop counts to enable easy expansion of 10/100Mb nets.  
User configurable Port 6 for Auto-negotiation or Full-Fixed (DS60C only)  
The Magnum DS60C sixth switched port has a manual switch underneath  
the port it controls. The user can manually select port #6 to Auto-negotiation as per  
the attached unit capability, or for Full-Fixed 100Mb FDX with no auto-negotiation..  
Standard Repeater ports for network diagnostic use  
Ports 1-5 are Ethernet Repeater ports, and operate by broadcasting packets  
received to all the other hub ports operating at the same speed. Because they are  
repeater ports, ports 1-5 may be used for network diagnostic tools such as a sniffer.  
Note that the ports operating at 10Mb and at 100Mb are in separate traffic domains.  
Compact Enclosure Allows for Versatile Installation with AC &DC  
The compact physical size of the Magnum DS50 / DS60 package allows it  
to be installed in office or lab locations. The rugged metal enclosure provides  
durability, and the internal universal power supply enables one model to be usable  
worldwide. The optional DC power supply with -48VDC or 24VDC qualifies the  
DS50 / DS60s for use in Industrial and telecom applications.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
2.5  
Applications  
The Magnum Dual-speed Hub Plus is designed to provide dual speed (10/100Mbps)  
connectivity. Pictured below, a Magnum DS50 Dual-speed Hubs serves a small office with  
mixed speed requirements. Some  
DS50  
users operate at 100Mbps, and some  
DS60  
Personal  
MagnuHmub Plus  
GARRETT  
users and utility devices (such as  
print servers) run at 10Mbps. All  
share the same hub, and  
P
WR  
LIN  
K
100L  
INK  
100LIN  
K
10L0INK  
10L0IN  
K
100  
UPLIN  
K
100  
10  
=
x
COL  
1
2
3
4
5
10/100  
M
b/s  
Connect to the main  
network  
communicate to each other via the  
bridge logic inside. Any node can change speed at any time without affecting network  
operation or impacting other users. It is simple to install and use, making shared Fast Ethernet  
networks practical for connecting high performance user groups in a variety of ways.  
Since 10/100 NICs are widely available at low cost, 100BASE-TX Fast Ethernet has  
become desirable for many performance-oriented users. They usually want their new 100Mb  
network segment to be interoperable with existing 10Mb networks, and to be a separate  
collision domain in order to maximize performance of both segments. This is where bridged-  
dual-speed provides flexibility by enabling the newly installed 100Mb ports to communicate  
smoothly with existing 10Mb nodes and hubs.  
For this example, DS60C Port 6 may be used as a 10Mb port to an existing 10Mb hub  
while Ports 1-5 are a new separate collision domain of shared 10/100 ports.  
Magnum DS60C  
Magnum DS60  
Personal Hub Plus  
GARRETT  
R
PWR  
LINK  
100 LINK  
10  
0
LINK  
10  
0
LINK  
100 LINK  
10  
0
X
UPLINK  
LK  
1
2
3
4
5
6
7
8
A
100  
POWER SPEED  
10  
0
M
AGNUM  
4K- Series  
=
x
FDX  
Ethernet 10/10  
0
Swit  
ch  
ERROR  
L
/
A
10  
COL  
UPLINK  
F/H  
1
2
3
4
5
6
10  
/100 Mb/s  
FF-A  
=
X
F
H
10  
10/100Mb Work Stations  
Magnum DS60  
Personal Hub Plus  
GARRETT  
R
X
PWR  
LINK  
100 LINK  
10  
0
LINK  
100 LINK  
100 LINK  
100  
UPLINK  
L
K
100  
100  
FDX  
=
x
1
0
COL  
1
2
3
4
5
6
10/100 Mb/s  
FF-A  
Magnum DS60  
Personal Hub Plus  
10  
10/100Mb Work Stations  
GARRETT  
R
PWR  
LINK  
100 LINK  
100 LINK  
10  
0
LINK  
100 LINK  
10  
0
X
UPLINK  
LK  
100  
10  
0
FDX  
=
x
10  
COL  
1
2
3
4
5
6
10  
/1  
00  
M
b/s  
FF-A  
10  
10/100Mb Work Stations  
Figure 2.4.1 : DS60C for different department with high bandwidth from switch port  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
To add more 10/100Mb stations, another 10/100Mb workgroup can be added using a DS60C  
hub. By placing the Magnum DS60C Dual-speed Hub Plus in the middle, it acts as a bridge  
separating the 10Mb and the 100Mb traffic domains and provides each department with full  
bandwidth.  
The previous examples show that the Magnum DS60C Dual-speed Hub Plus not only  
provides connectivity between a 100Mb workgroup and a 10Mb workgroup, but it also  
segments the local traffic of the new and the existing segments from each other. This type of  
configuration is ideal for adding a new 100Mb workgroup without slowing down the existing  
10Mb network with all the unwanted local packets from the new workgroup.  
Consider yet another situation in Figure 2.4.3 where a new 100Mb user group is to be  
added to an existing 100Mb network. The Magnum DS60C not only provides more 100Mb  
ports to the network, it also adds a collision domain giving configuration flexibility to the new  
user group. The existing network can grow without having to worry about cable distance  
limitations and repeater hop counts associated with the new segment.  
100Mb Workgroup  
Magnum DS60C  
100Mb Workgroup  
Magnum 8000  
E
1
1
1
2
PWR  
1
2
3
4
5
6
7
8
9
10  
Stacka ble ub  
H
GARR ETT  
Magnum 8000  
Stacka ble ub  
GARR ETT  
E
9
9
10  
10  
11 12  
11 12  
PWR  
PWR  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
H
Magnum 800E  
Workgroup Hub  
1
2
3
5
8
6
7
4
PWR CO  
L
LIN  
RX  
K
LIN  
RX  
K
Magnum 8000  
E
1
0
0
M
b
/
s
Stacka ble H ub  
GARR ETT  
GARR ETT  
Magnum 8000  
E
9
10  
1
1
1
2
PWR  
1
2
3
4
5
6
7
8
Magnum DS60  
Stacka ble ub  
H
GARR ETT  
Personal Hub Plus  
GARRETT  
R
PWR  
LINK  
100LINK  
100LINK  
100LINK  
100LINK  
100  
UPLINK  
XLK  
100  
FDX  
100  
10  
=
x
COL  
1
2
3
4
5
6
10/100 Mb/s  
FF-A  
Magnum 800E  
Workgroup HubPWR CO  
100 b/s  
GARR ETT  
1
4
2
3
5
6
7
L
LIN  
RX  
K
8
LIN  
RX  
K
M
10  
100Base-TX  
10/100Mb Work Stations  
Figure 2.4.3 : Joining two 100Mb workgroups with a Magnum DS60C  
The above figure shows two 100BSASE-TX segments connected via a Magnum  
DS60C. All packet forwarding and filtering is done by the Magnum DS60C and is transparent  
to the users, who only see one network in terms of node addresses. Performance of the network  
is enhanced as the available bandwidth on each segment will not be affected by the local traffic  
on the other segment.  
Since the DS60C Dual-speed Hub Plus segments the network, the bandwidth  
available for each collision domain is maximized.  
www  
.
GarrettCom  
.
com  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
In this example, a Magnum DS60F Dual-speed Hub serves in an Industrial place with servers  
and mixed-speed requirements, such as collecting data or downloading data from servers or  
other sources. Some users operate at 100Mbps, and some users and utility devices (such as print  
servers) run at 10Mbps. High performance users need a high bandwidth backbone for access to  
a central LAN and central file servers. A Magnum DS60F Dual-speed Hub with 24VDC or -  
48VDC power supply serves this requirement economically. The five dual-speed port  
capability and a 100Mbps Fiber port makes the required setup simple. Any attached node can  
change speed at any time without affecting network operation or impacting other users.  
Existing 10Mbps hub or switch users can easily be cascaded into any copper ports of  
the DS60F. This allows a simple plug-and-play addition of 100Mbps port to an existing  
10Mbps network without having to change it. Nodes that are capable of 100Mbps speed can be  
moved to a DS60F port, and will automatically operate at the higher speed.  
The 100Mb Full-duplex (default) fiber port on the DS60F can be used for  
accommodating high performance data transfers, and provides fiber connectivity built-in rather  
than needing an auxiliary media converter unit. The 100Mbps traffic does not use the  
bandwidth of the 10Mbps domain, so overall performance of the network is sustained at the  
highest possible level.  
Magnum  
Personal HDuSb60Plus  
GARRETT  
LINK  
1
0
0
LINK  
1
0
0
LINK  
1
0
0
LINK  
1
00  
LINK  
100  
UPLINK  
1
FDX  
0
=
x
1
2
3
4
b/s  
5
6
FF-A  
10/100  
M
Collecting data  
from M/C  
Magnum  
Personal HDuSb60Plus  
GARRETT  
LINK  
1
00  
LINK  
1
00  
LINK  
1
00  
LINK  
1
00  
LINK  
100  
UPLINK  
Magnum
1
FDX  
Black0
Mod
=
x
1
2
3
4
5
6
100/10  
LK  
FF-A  
10/100 Mb/s  
LK  
CT  
GA
100/10  
FDX/HDX  
Internet  
Router  
Collecting Data  
from M/C  
M
a
k
gnum  
group Hu  
/s  
8
0
0
b
E
1
4
2
3
5
8
6
7
W
o
r
PW  
R
COL  
L
I
NK  
L
I
NK  
10  
0
M
b
RX  
RX  
GA  
RRETT  
10Mb network  
Magnum  
Personal HDuSb60Plus  
GARRETT  
LINK  
1
00  
LINK  
1
00  
LINK  
1
00  
LINK  
1
00  
LINK  
100  
UPLINK  
1
FDX  
1
=
x
1
2
3
4
b/s  
5
6
FF-A  
10/100  
M
Collecting Data  
from M/C  
Fig 2.4.4 DS60s in Industrial use for collecting data from the M/C  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
3.0  
INSTALLATION  
This chapter provides instructions for installing the Magnum DS50 / DS60 Dual-  
speed Hub Plus.  
3.1  
Locating the Magnum DS50 / DS60 Dual-speed Hubs Plus  
The location of the Magnum DS50 / DS60 Dual-speed Hub Plus is dependent on the  
physical layout of the network and the workgroup to be bridge-isolated. The compact size of  
the unit allows it to be table-top, shelf or wall-mounted. Brackets for vertical mounting are  
included. The cooling fan in the bottom of the unit exhausts air underneath the unit, so the  
space around the rubber feet should be kept clear. (An optional floor stand for edge-mounting is  
available - see GCI’s Spare Parts List - and this stand is recommended for use on carpeted  
floors.)  
Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum  
DS50 / DS60 site. (For optional DC power, see Appendix B). The rugged metal case of the  
Magnum DS50 / DS60 will normally protect it from accidental damage in a lab or workplace  
setting. Keep an open area around the unit so that cooling can occur while the unit is in  
operation.  
3.1.1  
Table-Top or Shelf Mounting  
The Magnum DS50 / DS60 Dual-speed Hub Plus can be easily mounted on a table-  
top or any suitable horizontal surface. It also has four rubber feet to provide stability without  
scratching finished surfaces. Air from the cooling fan exhausts to the underneath side.  
3.1.2  
Wall (or Vertical Surface) Mounting  
GARRETT  
Magnum DS60  
PWR  
UPLINK  
Personal HubTM Plus  
100  
10  
=
x
COL  
100 Mb/s  
GARRETT  
bracket attachment  
Proper mounting  
Magnum DS60C, optional  
mounting brackets  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Each Magnum DS50 / DS60 Dual-speed Hub Plus is shipped with two mounting  
brackets (and screws), to allow the unit to be mounted in nearly any desired orientation or  
position. The brackets are attached to the unit’s case with one of the metal screws for each  
bracket. It is recommended that the brackets be attached to two opposite corners on the unit.  
The brackets should be attached to the Magnum DS50 / DS60 through the round hole of the  
bracket. When properly attached, the brackets will extend slightly below the base of the unit to  
allow clearance for the rubber feet.  
3.1.2  
A)  
Optional mounting methods, DIN-rail and E-Stand  
For DIN-rail mounting, a kit is needed that uses the metal mounting brackets (see  
3.1.1 above) to attach DIN-rail clips that hold the unit in a vertical position, Ethernet  
cables attaching at the bottom. For additional information on DIN mounting, email  
B)  
The E-Stand provides a  
vertical mounting option for  
the DS50 / DS60s. When  
horizontal placement is not  
possible or desirable (such as  
when the unit is placed on a  
carpeted floor, which would  
Screw holes  
potentially block air flow  
from the cooling fan), the E-  
Rectangular  
cut-out  
(Air Vent)  
Stand offers a convenient  
installation option. Simply  
align the rectangular cut-out on the E-Stand with the air vent on either side of the  
DS50 / DS60. The E-Stand also allows the DS50 / DS60 unit to be securely mounted  
via two screws that connect through the E-Stand and into the side of the unit.  
3.2  
Ethernet Media, connections and Specifications  
The Magnum DS50 / DS60 Dual-speed Hub Plus can be connected to the following  
three media types: 100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used  
when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3  
may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100  
meters (328 ft). For fiber port 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling  
can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling  
supports much longer cable distance and higher bandwidths as compared to copper wiring.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Media  
Installation and User Guide (06/02)  
IEEE Standard  
Connector  
RJ-45  
RJ-45  
SC  
Twisted Pair (CAT 3 or 5)  
Twisted Pair (CAT 5)  
Fiber (Multi-mode)  
10BASE-T  
100BASE-TX  
100BASE-FX  
100BASE-FX  
Fiber (Single-mode)  
SC  
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10Mbps and  
100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed  
network (since DS50 / DS60 hub ports are auto-sensing for either 10 or 100Mbps).  
Note that the auto-sensing function does not sense the cable type.  
3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or  
Shielded  
)
The following procedure describes how to connect a 10BASE-T or 100BASE-TX  
twisted pair segment to the RJ-45 port. The procedure is the same for both  
unshielded and shielded twisted pair cables.  
1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into  
the RJ-45 connector of the port. Note that, even though the connector is shielded, either  
unshielded or shielded cables and wiring may be used.  
2. Connect the other end of the cable to the corresponding device.  
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be  
illuminated when the unit is powered and proper connection is established. If this does  
not help, ensure that the cable is connected properly and that the device on the other end  
is powered and is not defective.  
4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch  
which has a cross-over or up-link for linking to another hub or Switch.  
3.2.2  
Connecting Fiber Optic SC-type, "Snap-In"  
The following procedure applies to installations using SC-type fiber connectors. This  
procedure applies to ports using multi-mode SC fiber connectors.  
1. Before connecting the fiber optic cable, remove the protective dust cap / plug from the  
end of the fiber connectors, exposing the ports opening. Save the dust cover / plug for  
future use, in case the fiber cable needs to be unplugged for service.  
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue  
dampened in alcohol. Make certain the connectors are clean before connecting. Then,  
insert the square male connector into the SC female jack of the Fiber port connector  
until it clicks and secures.  
Note:  
One strand of the duplex fiber optic cable may be coded using color bands  
at regular intervals; you should use the color-coded strand on the associated ports  
at each end of the fiber optic cable segment.  
3. Connect the Transmit (TX) port on the Magnum Fiber port to the Receive (RX) port of  
the remote device. Begin with the color-coded strand of the cable for this first TX-to-  
RX connection. Note – the two male square-end SC cable strands may be fastened  
together to plug as a unit.  
4. Connect the Receive (RX) port to the Transmit (TX) port of the remote device. Use the  
non-color coded fiber strand for this.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
5. The LINK LED for the fiber connector will illuminate when a proper connection has  
been established at both ends (and when power is ON in the unit). If LINK is not lit  
after cable connection, the normal cause is improper cable polarity. Swap the fiber  
cables at the fiber connector to remedy this situation.  
3.2.3  
Connecting Single-Mode Fiber Optic  
When using single-mode fiber cable, be sure to use single-mode fiber port  
connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125  
microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the  
diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full  
bandwidth at longer distances, about 20Km with the single-mode SC.  
The same procedures as for multi-mode fiber apply to single-mode fiber connectors.  
Follow the steps listed in Section 3.2.2 above.  
3.2.4  
Power Budget Calculations for DS60F Fiber Media  
Receiver Sensitivity and Transmitter Power are the parameters necessary to compute  
the power budget. To calculate the power budget of different fiber media installations using  
Magnum products, the following equations should be used:  
OPB (Optical Power Budget) = PT(min) - PR(min)  
where PT = Transmitter Output Power, and PR = Receiver Sensitivity  
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)  
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]  
where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,  
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,  
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km  
The following data has been collected from component manufacturer’s (HP’s and Siemens’)  
web sites and catalogs to provide guidance to network designers and installers.  
Fiber  
Port  
Module  
Speed,  
Std.  
Std. km Wave- Cable X’mitr R’cvr Worst Worst* typical typical*  
fdx length Size Output Sens. OPB, distance OPB, distance  
Mode  
(hdx) nm  
PT , dB PR ,dB dB Km, fdx  
dB  
Km, fdx  
µm  
DS60F-  
xMSC  
DS60F-  
xSSC  
Multi-  
mode  
2
(0.4)  
62.5/125 -20  
50/125 -23.5  
-31  
-31  
9.0  
5.5  
2.5  
2.0  
14  
12  
5
4
100Mb  
FX  
1300  
Single-  
mode  
20  
(0.4)  
100Mb  
FX  
1300 9/125  
-15  
-5  
-31  
-34  
14  
27  
28  
54  
17.5  
32.5  
35  
65  
Single-  
mode  
100Mb  
FX  
40  
(0.4)  
9/125  
“Long  
1300  
Reach”  
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over  
long distances (i.e., over approx. 400 meters) can be achieved only if the following  
factors are both applied:  
The 100Mb fiber segment must operate in full-duplex (FDX) mode, and  
The worst-case OPB of the fiber link must be greater than the fiber cable’s passive  
Attenuation.  
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
3.2.5  
Connections to NICs which support Auto-Negotiation, RJ-45 ports  
The copper ports of Magnum DS50 / DS60s will function properly with NICs  
(Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP)  
coding for the 100BASE-TX signaling system. When connecting a NIC to a DS50 / DS60, it  
may be necessary to reload the NIC drivers on the user device if the NIC has been  
communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When 100Mb  
speed is agreed and in use, the 10/100 LED is steady ON. It is OFF if there is no traffic or if  
there is 10Mbps traffic.  
In cases where 100BASE-TX connection ports are used as 10BASE-T ports, CAT 3  
may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100  
meters (328 ft).  
Media  
IEEE Standard  
10 BASE-T  
Connector  
RJ-45  
Twisted Pair (CAT 3 or 5)  
Twisted Pair (CAT 5)  
100BASE-TX  
RJ-45  
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps and  
100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed  
network, since dual-speed ports are auto-sensing for either 10 and 100Mbps. Note  
that the auto-sensing function does not sense the cable type.  
3.2.6  
Collision Domain Diameter  
The Collision Domain Diameter is the length of the longest path between any two  
devices in a single collision domain. A collision domain is defined as a cluster of network  
devices that are connected by means of a repeater or repeaters such that no bridging devices are  
present between any two devices in the cluster. In order to install an IEEE 802.3u compliant  
Fast Ethernet network, the collision domain, regardless of the actual network topology, must be  
less than 512 BT (Bit Times). Bit Times are related to media types as shown in Table 3.2a.  
Table 3.2a: Worst case round-trip delay for Fast Ethernet media*  
Media Type  
Round-trip delay in  
Bit Time per Meter (BT/m)  
1.000  
1.112  
1.112  
1.140  
1.140  
Fiber Optic  
Shielded TP cable  
Category 5 Cable  
Category 4 Cable  
Category 3 Cable  
*Worst case delays taken from IEEE Std 802.3u-1995, actual delays may be less for a particular cable.  
Contact your cable supplier for exact cable specifications.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Each Fast Ethernet device component also has an associated BT delay, which  
depends on the physical signaling system employed. Table 3.2b shows each Fast Ethernet  
device component and the associated BT delay. Note that there is only one DTE pair  
associated with any device-to-device path.  
Table 3.2b: Worst case round-trip delay for Fast Ethernet device components*  
Component  
Round-trip delay in Bit Times (BT)  
100  
100  
100  
138  
127  
140  
2 TX DTEs  
2 FX DTEs  
1 FX and 1 TX DTE  
2 T4 DTEs  
1 T4 and 1 TX or FX DTE  
Class I Repeater  
92  
Class II Repeater with any  
combination of TX and FX ports  
**Note, the delay is only 80 Bit Times  
for the MagnumDS50 / DS60, ports 1-5.  
*Worst case delays taken from IEEE Std 802.3u-1995.  
To determine whether a prospective network topology adheres to the collision  
domain diameter specification, the following formula should be applied to the worst case path  
through the network. The worst case path is the path between the two Fast Ethernet devices  
(DTEs) which have the longest round trip time.  
PDV = (sum of cabling delays) + (sum of repeater delays) +  
(DTE pair delay) + (safety margin)  
PDV is the Path Delay Value of the worst case path. For the network to adhere to  
IEEE standard, this value must be less than 512 BT. The safety margin is specified in BT and  
may be a value between 0 and 5. This margin can be used to accommodate unexpected delays,  
as seen when using extra long patch cables. A safety margin from about 2 to 4 BT is  
recommended.  
A typical example of a  
PDV calculation is shown to the  
right. The example is illustrated in  
Figure 3.2a. Here, an integrator  
wishes to cascade two industry-  
standard Fast Ethernet hubs with  
100m Category 5 user segments  
(i.e., from computer to hub) and  
Cat. 5 cable for  
cascading  
Industry-  
Standard  
100Mb/s Hub  
PWR COL  
LINK  
RX  
Industry-  
Standard  
100Mb/s Hub  
PWR COL  
LINK  
RX  
100 m cat. 5 cables  
to user devices  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
needs to know the total length of the Category 5 cable used to cascade the hubs. The variable  
“X” is used to represent the unknown maximum cascade length.  
PDV = X + ((111.2 + 111.2) + (92 + 92) + (100) + 0 ) BT < 512 BT  
512 > (X + 506.4) BT  
X
X
X
X
< (512 - 506.4) BT  
< 5.6 BT  
< (5.6 BT) / (1.112 m/BT)  
< 5.03 m  
5.03 m maximum length for Category 5 cascaded cable  
If the integrator uses Magnum hubs, he can increase the length of the cascaded  
segment.  
Additionally, as the Magnum hubs have a lower delay value (60BT rather than  
92BT), the integrator can cascade three Magnum hubs with the maximum user cable lengths.  
The calculation is shown below. The variable “X” is used to represent the unknown maximum  
cascade length.  
PDV = X + ((111.2 + 111.2) + (60 + 60 + 60) + (100) + 0 ) BT < 512 BT  
512 > (X + 502.4) BT  
X
X
X
X
< (512 - 502.4) BT  
< 9.6 BT  
< (9.6 BT) / (1.112 m/BT)  
< 8.63 m  
8.63 m maximum total length for Category 5 cascading segments,  
Where 111.2 is the BT delay for 100m of Category 5 cable (1.112 BT/m* 100m), 60 is the BT  
delay for each of the Magnum hubs, 100 is the BT delay for the TX DTE pair, and a safety  
margin of 0 was used. (Note the internal switch on port 6 does not enter into this calculation of  
one collision domain’s cable lengths. If used, port 6 of the Magnum DS60C when set to 100Mb  
has a PDV of 50BT, the same as a NIC or node.).  
The resulting value tells us that two Category 5 cables whose combined lengths do  
not exceed 8 meters may be used to cascade the three Magnum DS50 & DS60’s. Note that this  
cable length may alternatively be increased by shortening the lengths of the 100m cables to  
users.  
Table 3.2c shows maximum cable lengths for common network configurations. The  
above calculations should be performed for calculations not listed in the table.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Table 3.2c: Maximum segment lengths for common network configurations  
Number Repeater  
of Hubs Hop Count  
Max. User  
Segment Repeater (Cascade)  
Max. Inter-  
Notes  
Lengths (m)  
100.0  
Length (m)  
N/A.  
1
2
2
2
1
2
2
2
All ports TX  
All ports TX  
All ports TX  
1 hub T4, 1 hub TX and T4  
(class I repeater), all cables  
Cat. 5  
100.0  
92.0  
79.5  
5.0  
20.0  
1.0  
3+  
3
60.0  
1.0  
All ports TX  
3.3  
Powering the Magnum DS50 / DS60  
Magnum DS50 / DS60 Dual-speed  
Hub Plus incorporates an internal universal  
power supply and has a recessed male IEC  
connector for the AC power cord at the right-  
rear. A six-foot 115vac 60Hz power cord is  
AC Power: Auto-ranging  
100-240 vac, 47-63 Hz  
supplied with each unit shipped within the United States and Canada.  
Each DS50 / DS60 auto-ranging power supply supports installation environments where  
the AC voltage is from 100 to 240 volts with an input frequency between 47 and 63 Hz, and  
consumes a maximum of 20 watts.  
In order to power down the unit, simply unplug either end of the power cable.  
NOTE: The DC Power Supply option, -48VDC and 24VDC are described in APPENDIX B.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
4.0  
OPERATION  
This chapter describes the function and operation of the Magnum DS50 / DS60.  
4.1  
Dual-Speed Functionality  
The repeater ports (port #1-5) of a Magnum DS50 / DS60 handles the two different  
traffic domains separately. The DS50 / DS60 provides switched (bridged) connectivity between  
the Ethernet (10Mbps) and Fast Ethernet (100Mbps) domains. It joins the two network  
domains for unified operation and filters/ forwards packets in both directions to maximize  
bandwidth utilization and performance. The Magnum DS50 / DS60 is a hardware plug-and-  
play device. There is no software set-up to be done at installation or for maintenance. The  
functions of the DS50 / DS60 is described in this manual.  
Each time a packet is received on one domain of the bridge logic, the decision is  
taken to either filter or forward the packet. Error packets are always filtered. For good packets,  
the filter and forward decisions are made based on the destination addresses contained in each  
packet. If the destination address is on the same domain from which the packet originated, then  
it is filtered and not forwarded to the other domain. If the destination address is not found to be  
a match in the address table for the originating domain, then it is forwarded to the other  
domain. If it is a new node address coming in which the switch did not previously know about,  
it “learns” the new address and puts it in the correct port address table. See “Address Learning”  
for more details.  
This diagram below shows the filter / forward logic for both domains at port # 1-5.  
Magnum DS50 / DS60  
10Mb Domain :  
10Mbps packets are  
forwarded when the destination addresse is  
NOT in the 10Mb domain address table.  
100Mbps Domain1:00Mbps packets are  
forwarded when the destination address is  
NOT in the 100Mb domain address table.  
10Mbps Domain :10Mbps packets are  
filtered when the destination address is  
Bridge I.C.  
in the 10Mbps domain address table.  
100 Mbps Domain  
100 Mbps Traffic  
10 Mbps Domain  
10 Mbps Traffic  
100Mbps Domain :100Mbps packets are  
filtered when the destination address is  
in the 100Mbps domain address table.  
Figure 4.1 : Filtering and Forwarding at port (1-5) in DS50 / DS60 Dual-speed Hubs  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
Packet  
Source  
10 Mbps Not in table  
10Mbps  
10Mbps  
10Mbps  
Source  
Address  
Destination  
Address  
Not in table  
In table  
Not in table  
In table  
Address Table  
Filter/Forward  
Action  
Forward  
Filter  
Forward  
Filter  
Maintenance  
Add source to table  
Add source to table  
None  
Not in table  
In table  
In table  
None  
100Mbps Not in table  
100Mbps Not in table  
100Mbps In table  
Not in table  
In table  
Not in table  
In table  
Add source to table  
Add source to table  
None  
Forward  
Filter  
Forward  
Filter  
100Mbps In table  
None  
Table 4.1: DS50 / DS60 Dual-Speed Hub Functionality  
2.  
Address Learning (Address Table Maintenance)  
The Magnum DS50 / DS60 bridge logic is a state machine design which has a total  
address table capacity of 2K addresses. With a large address table, a Magnum DS50 / DS60 can  
serve the needs of medium-sized to large networks. Table 4.1 shows what filter / forward  
action the Magnum DS50 / DS60 will take in each packet-processing situation and when a new  
node address will be added to the internal Address Table. When a new node-address packet  
comes into a port for the first time, then the new source address is “learned” at the same time  
that the packet is forwarded. After learning, subsequent packets from the same node address  
are routinely processed. The address tables are flushed periodically to update the network status  
and to purge any inactive stations from the tables of both domains.  
3.  
Throughput Increase  
By selectively forwarding packets from each domain to the other domain based on  
its switching (bridging) logic, the Magnum DS50 / DS60 increases the available bandwidth for  
the users on both sides of the network. As shown in Figure 4.1, it keeps the local traffic on each  
side contained, preventing unnecessary packets and bad packets from traveling to the other  
domain and using up bandwidth needlessly. This results in more available network bandwidth  
on both sides and a throughput increase for all users on both domains.  
4.  
Software Transparency  
The Magnum DS50 / DS60 Dual-speed Hub need no software set-up and is  
transparent to system and application software, including network management software.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
4.2  
Auto-negotiation and speed-sensing  
The first five RJ-45 ports independently support auto-negotiation for shared  
10BASE-T and 100BASE-TX modes. Operation is according to the IEEE 802.3u standard.  
When an RJ-45 cable connection is made and each time a LINK is enabled,  
auto-negotiation takes place. The DS50 / DS60 advertises it’s capability for 10 or 100Mbps  
speed, and the device at the other end of the cable should similarly advertise / respond. Then  
both sides will agree to the speed to be used. Depending upon the device connected, this will  
result in agreement to operate at either 10Mbps or 100Mbps speed.  
When the ‘10 M LINK/ACT’ LED is ON, either steady or blinking (see below),  
the port has auto-negotiated for 10Mbps operation. (If a DS50 / DS60 port is connected to a  
non-negotiating device, it will default to 10Mbps speed and half-duplex mode, per the  
IEEE802.3 standard). Similarly, when the ‘100M LINK/ACT’ LED is lit, it means 100Mbps  
operation. Since Magnum DS50 / DS60 are hubs, they always operate in the shared or half-  
duplex mode on first five (1-5) ports.  
4.3  
Switching Functionality for port # 6 (DS60s Only)  
A Magnum DS60 Dual-speed Hub Plus provides switched connectivity at Ethernet  
wire-speed for port #6. The Magnum DS60C supports 10/100Mbs for copper media to  
maximize bandwidth utilization and network performance. Similarly Magnum DS60F supports  
100Mbps for Fiber media to maximize bandwidth utilization, network performance and secured  
longer distance. All ports can communicate to all other ports in a Magnum DS60, but local  
traffic on port #6 will not consume any of the bandwidth on any other port.  
Magnum DS60 units are plug-and-play devices. There is no software configuring to  
be done at installation or for maintenance. Full duplex and Auto-negotiation mode at 10 or  
100Mbps for the switched copper port can be done through the manual switch underneath the  
port it controls. Similarly the Fiber switched port at 100Mbps can be set at Full duplex as well  
as Half-duplex through the manual switch underneath the port it controls. The internal functions  
of switched port are described below.  
Filtering and Forwarding  
Each time a packet arrives on one of the switched ports, the decision is taken to either  
filter or to forward the packet. Packets whose source and destination addresses are on the same  
port segment will be filtered, constraining them to that one port and relieving the rest of the  
network from processing them. A packet whose destination address is on another port segment  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
will be forwarded to the appropriate port, and will not be sent to the other ports where it is not  
needed. Traffic needed for maintaining the operation of the network (such as occasional multi-  
cast packets) is forwarded to all ports.  
The Magnum DS60’s switched port operates in the store-and-forward switching  
mode, which eliminates bad packets and enables peak performance to be achieved when there  
is heavy traffic on the network.  
Address Learning  
The switched port at Magnum DS60 units have address table capacity of 8K node  
addresses, and 1MB dynamically allocated packet buffers, suitable for use in small and medium  
size networks. They are self-learning, so that as nodes are added or removed or moved from  
one segment to another, the DS60’s switched port automatically keeps up with node locations.  
An address-aging algorithm causes least-used addresses to fall out in favor of new  
frequently-used addresses. To reset the address buffer, cycle power down-and-up.  
4.4 LEDs  
PWR : Steady ON when power applied.  
COL 100 (port 1-5) : Collision, flashing when collision occurs on ports 1-5.  
at 100Mbps.  
COL 10 (port 1-5) : Collision, flashing when collision occurs on ports 1-5  
at 10Mbps.  
LK/RX (port 1-5)  
: Steady ON when twisted pair link is operational,  
Activity , flashing when port is receiving data.  
: Speed is at 100Mbps .  
100 (port 6)  
FDX (port 6)  
: Port is at Full-Duplex.  
4.5  
(FF-A) Manual Switch, Port 6 for DS60C  
The FF-A slide switch  
“FF-A” Switch  
allows users to configure Port 6 as either a  
Full fixed at 10/100 port or act as an Auto-  
negotiation Ethernet port. It is located  
underneath Port 6 on the right front panel of  
the Magnum DS60C. See figure 2.2.3 for  
location of the switch relative to Port 6.  
FF  
A
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
After switching from Full fixed to auto-negotiation or vice versa, it is necessary  
that the unit be powered down and back up to reset the internal buffers of the switch. Even  
though it is not always required, powering down and up will enable proper packet handling  
in all cases for both segments of the network.  
4.6  
(F-H) Manual Switch, Port 6 for DS60F  
“F-H” Switch  
The manual switch  
provided underneath the Switched fiber port#6, allow the  
user to set the fiber port at 100Mbps Full duplex or  
100Mbps Half-duplex.  
F
H
The F and H switch enable this Dual-speed Hub plus to easily connected to any  
other Fiber Switch or Hub. The Full-Duplex 100Mbps fiber port supports a much longer  
distance then the 100Mbps Half Duplex in any fast Ethernet network.  
4.7  
Up-link Switch, Port 1  
The Magnum DS50 & DS60C is equipped with one  
UP-LINK  
up-link slide switch for port 1. This allows repeater-to-repeater  
connections without a special cross-over cable. The up-link  
switch is located to the left of port 1.  
Set the slide switch to the left “=” position  
Figure 4.4: Up-link Switch  
for twisted pair cable segments from the DS50 & DS60C port to a user device. Set the slide  
switch to the right “X” position for cascaded or up-link segment connections from the  
DS50 & DS60C port 1 to another repeater or hub in the network. Verify proper switch  
position by noting the port’s LINK LED status, which illuminates when proper link is  
established.  
www  
.
GarrettCom  
.
com  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
5.0  
TROUBLESHOOTING  
All Magnum Ethernet products are designed to provide reliability and  
consistently high performance in all network environments. Both the installation and  
operation of a Magnum DS50 / DS60 Dual-speed Hub Plus are simple procedures (see  
Section 3.0, INSTALLATION); operation is very simple and is described in Section  
4.0.  
Should problems develop during installation or operation, this section should help  
to locate, identify and correct such problems. Please follow the suggestions listed  
below prior to contacting your supplier. However, if you are unsure of any procedure  
described in this section, or if the Magnum DS50 / DS60 is not operating as expected,  
do not attempt to repair or alter the unit. Contact your supplier (or if unknown, contact  
GarrettCom) for assistance.  
5.1  
Before Calling for Assistance  
1.  
2.  
If difficulty is encountered when installing or operating the Magnum DS50 / DS60,  
refer back to Section 3.0, Installation and Section 4.0, Operation. Check to make  
sure that the various other components of the network are operable.  
Check the cables and connectors to ensure that they have been properly  
connected and the cables/wires have not been crimped or in some way  
impaired during installation. (About 90% of network downtime can be attributed  
to wiring and connector problems.)  
3. Be certain that the AC power cord is plugged into a functioning electrical outlet.  
Make sure that the AC power cord is properly plugged into the DS50 / DS60 unit.  
Use the PWR LED to verify that the unit is receiving proper power.  
4. If the problem is isolated to a network device other than the Magnum DS50 / DS60, it  
is recommended that the problem device be replaced with a known good device.  
Verify whether or not the problem is corrected. If not go to Step 5 below. If the  
problem is corrected, the Magnum DS50 / DS60 and its associated cables are  
functioning properly.  
5. If the problem continues after completing Step 4 above, contact your supplier of the  
Magnum DS50 / DS60 unit (or if unknown, contact GarrettCom) by fax or by phone  
for assistance.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
5.2  
When Calling for Assistance  
Please be prepared to provide the following information.  
A complete description of the problem, including the following points:  
a. The nature and duration of the problem;  
1.  
b. Situations when the problem occurs;  
c. The components involved in the problem;  
d. Any particular application that, when used, appears to create the problem;  
2.  
3.  
An accurate list of GarrettCom product model(s)involved, with serial number(s).  
Include the date(s) that you purchased the products from your supplier.  
It is useful to include other network equipment models and related hardware,  
including personal computers, workstations, terminals and printers; plus, the  
various network media types being used.  
4.  
A record of changes that have been made to your network configuration prior to  
the occurrence of the problem. Any changes to system administration procedures  
should all be noted in this record.  
5.3  
Return Material Authorization (RMA) Procedure  
All returns for repair must be accompanied by a Return Material Authorization  
(RMA) number. To obtain an RMA number, please use this URL -  
have the following information readily available:  
Name and phone number of your contact person.  
Name of your company / institution  
Your shipping address  
Product name  
Serial Number (or Invoice Number)  
Packing List Number (or Sales Order Number)  
Date of installation  
Failure symptoms, including a full description of the problem.  
GarrettCom will carefully test and evaluate all returned products, will repair  
products that are under warranty at no charge, and will return the warranty-repaired units to  
the sender with shipping charges prepaid (see Warranty Information, Appendix A, for  
complete details). However, if the problem or condition causing the return cannot be  
duplicated by GarrettCom, the unit will be returned as:  
No Problem Found.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
GarrettCom reserves the right to charge for the testing of non-defective units  
under warranty. Testing and repair of product that is not under warranty will result in a  
customer (user) charge.  
5.4  
Shipping and Packaging Information  
Should you need to ship the unit back to GarrettCom, please follow these instructions:  
1. Package the unit carefully. It is recommended that you use the original container if  
available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for  
shipping protection. ( You may retain all connectors and this Installation Guide.)  
CAUTION Do not pack the unit in Styrofoam "popcorn" type packing material.  
:
This material may cause electro-static shock damage to the unit.  
2. Clearly mark the Return Material Authorization (RMA) number on the  
outside  
of the shipping container.  
3. GarrettCom is not responsible for your return shipping charges.  
4. Ship the package to:  
GarrettCom, Inc.  
47823 Westinghouse Dr.  
Fremont, CA 94539  
Attn.: Customer Service  
APPENDIX A: WARRANTY INFORMATION  
GarrettCom, Inc. warrants its products to be free from defects in materials and  
workmanship for a period of three (3) years from the date of shipment by GarrettCom.  
During this warranty period, GarrettCom will repair or, at its option, replace  
components in the products that prove to be defective at no charge other than shipping  
and handling, provided that the product is returned pre-paid to GarrettCom.  
This warranty will not be effective if, in the opinion of GarrettCom, the product  
has been damaged by misuse, misapplication, or as a result of service or modification  
other than by GarrettCom.  
GarrettCom reserves the right to make a charge for handling and inspecting any  
product returned for warranty repair which turns out not to be faulty.  
Please complete the warranty card as this acts as a product registration, and mail  
it to GarrettCom within two weeks of your purchase.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
APPENDIX B : Optional 24VDC or -48VDC Power Supply  
B1.0  
SPECIFICATIONS - FOR MAGNUM DS50 / DS60 DUAL-SPEED HUBS PLUS  
Power Supply (Internal -48VDC Option)  
DC Power Connector: 3 terminals: (-), “GND”, (+)  
Input Voltage: -36 to -72 VDC  
Power Consumption: Model DS50 / DS60: 6 watts typical, 10 watts max.  
Power Supply (Internal 24VDC Option)  
DC Power Connector: 3 terminals: (-), “GND”, (+)  
Input Voltage: 20 to 36 VDC  
Power Consumption: Model DS50 / DS60: 5 watts max.  
With the exception of the power supply, all specifications and functions of Magnum DS50  
/ DS60 24VDC or -48VDC models are identical to those listed in the main manual.  
B2.0  
24VDC or -48VDC POWER OPTION, THEORY OF OPERATION  
The 24VDC or -48VDC power option is designed using diodes inside on each DC  
HUB  
power input line behind the two external  
power connection terminals, so that the power  
from an external source can only flow into the  
hub. This allows the DS50/60 to operate only  
whenever DC power is correctly applied to  
SUPPLY  
+
A+  
A-  
FUSE  
-
CHASSIS  
GND  
GND  
the two inputs. It protects the hub from incorrect DC input connections. An incorrect polarity  
connection, for example, will neither affect the Dual-speed Hubs, nor its power supply  
internally, nor will it blow the fuse in the internal power supply.  
B3.0  
APPLICATIONS FOR DC POWERED ETHERNET HUBS  
Magnum DS50 / DS60 are easily installed in a variety of applications where 24VDC  
or -48VDC power is used as the primary power source. The –48VDC and 24VDC power  
configuration provides an Ethernet networking solution utilizing a special power supply in hubs  
with a proven track record.  
The –48VDC solution is particularly useful in the telecommunication industry, where  
it is common for facilities to operate on -48VDC power. Such companies include regular and  
wireless telephone service providers, Internet Service Providers (ISPs) and other  
communication companies. In addition, many high availability equipment services, such as  
broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use a  
battery backup system to maintain operations in the event of a power failure. It is also  
frequently used for computer system backup, management and operations monitoring  
equipment.  
The 24VDC solution is particularly useful in the Industrial environment, where it is  
common for facilities to operate on 24VDC power. The 24VDC application is mainly used in  
the Industrial environment, such as chemical plants, paper mill, stone quarrying plant,  
wastewater treatment Plant etc.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Magnum DS50 / DS60s Dual Speed Hubs  
Installation and User Guide (06/02)  
_
B4.0  
INSTALLATION  
GND  
+
This section describes the  
installation of the 24VDC or -48VDC  
power source leads to the 24VDC or -  
48VDC power terminal block on the  
Magnum DS50 / DS60. (see figure  
right).  
-36 to -70VDC  
Figure B4.1: Optional Terminal Block on Magnum DS50 / DS60 with -48VDC power  
In this picture, the 24VDC or -48VDC terminal block on the Magnum DS50 / DS60  
is located on the rear of the unit and is equipped with three (3) screw-down lead posts. The  
leads are identified as negative (-), positive (+), and chassis ground (GND).  
The actual connection procedure is very straightforward. Simply connect the leads to  
the Magnum unit, beginning with ground. Ensure that each lead is securely tightened.  
Note: The GND should be hooked up first. The DS50/60 unit has a floating  
ground, so the user may elect to Ground either + or = terminal to suit the customer’s use.  
Before connecting hot lines to the Terminal Block of –48VDC or 24VDC, always  
use a digital voltmeter to measure the output voltage of the power supply and determine the  
lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply  
must be connected to the post labeled “+”.  
An optional ON-OFF manual switch, available on some Magnum units, is not  
included on the Magnum DS50 / DS60 Dual-speed Hubs Plus.  
B4.1  
UL Requirements  
1. Minimum 14 AWG cable for connection to a Centralized DC power source.  
2. Fastening torque of the lugs on the terminal block: 9 inch pound max.  
3. Centralized DC Power Source cable securement, use at least four cable ties to secure  
the cable to the rack at least 4 inches apart with the first one located within 6 inches  
of the terminal block.  
B5.0  
OPERATION  
Operation of the Magnum DS50 / DS60 with the optional 24VDC or -48VDC power  
supply is identical to that of the standard AC-powered models.  
B6.0  
ORDERING INFORMATION  
To order the optional -48VDC power supply factory installed, add a suffix of “--  
48VDC” after the product’s standard model #. Example: Magnum DS50-48VDC.  
Similarly, to order the optional 24VDC industrial specific power supply factory  
installed, add a suffix of “ 24VDC” after the product ‘s standard model #.  
Example: Magnum DS60- 24VDC.  
B7.0  
TROUBLESHOOTING  
Please refer to Section 6.0 for troubleshooting  
www  
.
GarrettCom  
.
com  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Brush Cutter SRM 340 User Manual
Electro Voice Speaker EVX 180B User Manual
Everpure Water System EV9256 17 User Manual
Fisher Price Baby Toy x3189 User Manual
Frigidaire Washer Dryer 137337100B12022 User Manual
Frymaster Fryer Protector Series User Manual
Fundex Games Games Paddle Pool User Manual
GE Computer Monitor LTC MAP User Manual
GE Microwave Oven WES0930 User Manual
GE Washer WWM869M User Manual