GE Monogram Refrigerator ZISS360DMSS User Manual

Monogram.  
ZISS360DMSS - GE Monogram 36" Built-In Stainless Steel Refrigerator with  
Dispenser and Water Filter  
THE INSTALLATION SPACE  
36" Models 12"  
35-1/2  
35"  
* Shipping height.  
The refrigerator can  
be adjusted to fit into  
a cutout that is 83-  
1/2min. to 84-1/2”  
max. height Note that  
the top case trim at  
the front is 1/2”  
Case Width  
7"  
Electrical  
*84" From  
Floor to  
Top Frame  
84 1/2" max  
83 1/2" min  
Finished  
Area  
5"  
*83-1/2"  
at  
Rear  
74" From Floor  
to Bottom  
Opening  
higher and will  
overlap upper  
cabinetry or soffit.  
Use leveling legs and  
wheels for height  
adjustment.  
24"  
5"  
of Electrical  
36"  
Frame to Frame  
5"  
Water Supply  
3 1/2"  
3 1/2"  
Product Clearances  
Water And Electrical Locations  
These refrigerators are equipped with a 2 position door  
stop. The factory set 130° door swing can be adjusted  
to 90° if clearance to adjacent cabinets or walls  
is restricted.  
The opening must be prepared with the electrical and water  
supply located as shown.  
The cutout depth must be 24".  
Designed for industry standard flush installation. The  
refrigerator will project forward, slightly beyond adjacent  
cabinetry, depending on your installation.  
15"  
13"  
23-7/8"  
Behind  
Frame  
The cutout depth beneath a soffit:  
When installed beneath a soffit, the soffit cannot exceed the  
24” installation depth shown. The top case trim overlaps the  
bottom of the soffit.  
Frameless cabinets:  
20-5/8  
The case trim overlaps cabinets at the top and sides.  
Therefore, frameless cabinets may require filler strips to  
prevent interference with cabinet door swing. The opening  
must allow for filler strips.  
Allow minimum clearances for freezer door and  
fresh food door for a full 130° door swing and to  
allow for pan removal.  
Additional Specifications  
A 115 volt 60Hz., 15 or 20 amp power supply is required. An  
individual properly grounded branch circuit or circuit breaker  
is recommended. Install a properly grounded 3-prong electrical  
receptacle recessed into the back wall. Electrical must be  
located on rear wall as shown.  
4" minimum clearance is required when door  
swing is adjusted to 90°. If the 90° door stop  
position is used, pan access is maintained, but  
pan removal is restricted.  
Note: GFI (ground fault interrupter) is not recommended.  
Water line can enter the opening through the floor or back  
wall. The water line should be 1/4" O.D. copper tubing between  
the cold water line and  
water connection location, long enough to extend  
to the front of the refrigerator. Installation of an easily  
accessible shut off valve in the water line is recommended.  
®
For answers to your Monogram, GE Profile or  
GE appliance questions, visit our website at  
GEAppliances.com or call  
®
GE Answer Center service, 800.626.2000.  
Specification Revised 2/02  
Listed by  
Underwriters  
Laboratories  
As an ENERGY STAR® Partner,  
R
GE has determined that this product  
meets the ENERGY STAR®  
Download from Www.Somanuals.com. All Manuals Search And Downloagdui.delines for energy efficiency.  

Exmark Lawn Mower 720000 Higher User Manual
Fellowes Chipper OD500C User Manual
Fisher Price Baby Toy 77897 User Manual
Fisher Price Motorized Toy Car BGW46 User Manual
Focal Car Speaker 165 KR2 User Manual
Fujitsu Scanner P2WW 2646 01ENZ0 User Manual
Fundex Games Games Wildfire User Manual
Gardena Lawn Aerator EVC1000 User Manual
GE Monogram Ventilation Hood ZV30 User Manual
GE Waffle Iron 169118 User Manual