PKD915BM/WM
GE Profile™ 27" Warming Drawer
Under Oven Installation
23-1/2"
min.
Dimensions and Installation Information (in inches)
Optional Accessories:
KW Rating
Warming Drawer Dimensions
JXPN2 – Optional Pan Set
Accessory for Warming
Drawer. Two commercial
pans with lids (4” deep)
ZXD30B –1/4” panel kit
capability
.45
Breaker Size
15 Amps
120V
23-1/2" Min.
Inside
Locate
electrical
outlet in
adjacent
cabinet
16" from
left side
or 42"
Oven
cutout
120V
2" min.
2x2 or 2x4
anti-tip block
against rear
wall 9" from
floor to bottom
of block
9
Undercounter Installation: A solid barrier must be
installed at least 1” from the lowest point of the
bottom of cooktop burner box to the top of the
cutout. Use any solid material such as 1/4”-thick
plywood. Allow at least 1/4” air gap between the
barrier and the top of the warming drawer. See
label on top of the warming drawer for approved
cooktop models.
Allow 5/8"
overlap on
all sides
23-1/4
9-1/4
from right
side.
25-1/2
23-1/4
9-1/4
10-1/2
10-1/2
25-1/2
24"
recommended
from floor
for under
countertop
installation
1" Min. above toekick
or adjust to oven
26-3/4
26-3/4
installation height
Under Oven Installation: Additional clearance
between cutouts may be required. Check to be
sure that oven supports above the warming drawer
location do not obstruct the required interior 23-1/2”
depth and 9-1/4” height.
Undercounter Installation
Electrical outlet
1-1/2"
Cabinet top
Electrical outlet 42" max. from
flush with side of right side
cabinet 7" max.
Install 2x4 or 2x2
Install
Door handle protrudes 2-3/4” from door face.
Cabinets and drawers on adjacent 45° and 90°
walls should be placed to avoid interference with
the handle.
25
anti-tip block against
rear cabinet wall 9" from
floor to bottom of block
Install a solid barrier
2x4 or 2x2
Anti-Tip
below a cooktop
(see note).
7
9
Block 9"
From Floor
to Bottom
of Block
36"
Countertop
height
1"Min.*
9-1/4
9
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.
Electrical
outlet 16" max.
from left side
25-1/2
2x4 or 2x2
runners or solid
bottom
Solid barrier
1/4" Air gap
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
23-1/2 min.
Install a solid barrier
and a 1/4" min. air gap
above warming drawer.
Listed by
Underwriters
Laboratories
Specification Created 1/07
221132
Download from Www.Somanuals.com. All Manuals Search And Download.
|