Gardena Water Dispenser C 1060 profi User Manual

®
GARDENA  
C1060 profi  
Art. 1815  
GB Operating Instructions  
Water Computer Profi  
S
Bruksanvisning  
Bevattningscomputer  
NL Gebruiksaanwijzing  
Besproeiingscomputer  
D
Gebrauchsanweisung  
Bewässerungscomputer  
FIN Käyttöohjeet  
Kasteluohjain  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Function  
The battery must be exchanged in time to pre-  
vent the Water Computer failing due to a low  
battery when you are away for longer periods  
of time. Make sure that the time the battery  
has been in operation and the time you are  
planning to be away does not add up to more  
than a year.  
does not affect the program in any way.  
When the computer cools down the LCD  
display illuminates again.  
This GARDENA Water Computer C 1060 profi allows you  
to water your garden completely automatically any time you  
choose up to 6 times a day, whether you are using a sprinkler,  
a sprinkler system installation or a drip-head watering system.  
The max. temperature for the water flow is  
40°C.  
v Only use clear fresh water.  
Your Water Computer waters your garden completely automati-  
cally according to the program you choose. You can use your  
Water Computer to water your garden early in the morning or  
late at night when water evaporates the least or when you are  
on holiday.  
The minimum operating pressure is 0,5 bar,  
the maximum operating pressure is 12 bar.  
Setting up  
Avoid tensile strain.  
Warning! The Water Computer must not be  
used indoors.  
v Do not pull the hose connected to the  
You simply program the watering start, watering time and watering  
day(s) or cycles.  
Water Computer.  
v Only use the Water Computer outdoors.  
The Water Computer may only be set up verti-  
cally with the sleeve nut to the top to prevent  
water penetrating into the battery compart-  
ment.  
Programming  
v Program the Water Computer with the tap  
Key-operated functions  
Key  
Key-operated function  
turned off.  
Changes or moves on the input data. (If the  
-key is held down, the figures change very  
quickly.)  
1
In this way you can avoid getting wet when  
trying out the manual On/Off function (man.  
On/Off). You can remove the control unit from  
the housing to program the Water Computer.  
The minimum water output to ensure that  
the Water Computer functions correctly is  
20- 30 l/h.  
For example, at least 10 x 2-litre Drip Heads  
are required to control the Micro-Drip-System.  
O.K.  
Menu  
man.  
On/Off  
Confirms the values set with the -key.  
2
3
4
Changes to the next program level.  
For switching the water throughput on or off  
manually.  
At high temperatures (over 60°C at the dis-  
play) the LCD display may extinguish. This  
4 1 2 3  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Displays  
Display  
Description  
Batt.  
If the battery indicator begins to flash, the battery  
is almost flat and watering programs will no longer  
run. Any valves that are still open are closed again  
even if the battery is almost flat.  
F
G
Weekdays Current weekday or programmed watering days.  
(Mo, Tu,...)  
Prog.  
special  
5
6 9 0 A 7 C  
F
G
Program selected (1 to 6).  
6
7
The battery indicator is reset as soon as you  
replace the battery with a new one.  
Only for controlling the Automatic Water  
Distributor Art.-No. 1198.  
Prog.  
Off  
Watering program inactive  
(Budget function: 0%)  
time  
Flashes when in input mode for the current data  
(hours, minutes, day of the week).  
8
9
0
A
START  
PM  
Flashes when in input mode for watering  
start time.  
The four display levels  
Display levels  
Level 1:  
Level 2:  
Level 3:  
Level 4:  
Normal display  
Enter the current time and day of the week  
Insert watering programs  
D
5 8 E  
B
Display for 12-h-clock  
(e. g. in USA, Canada).  
(Time/  
Current time / Watering start time  
% Run-Time / Prog. Off  
Start time) (display 13 h = 1 pm; e. g. in USA, Canada).  
RUN Time  
3rd, 2nd  
can be selected one after the other by pressing the Menu-key.  
Watering time (flashes when in input mode).  
B
C
Watering cycles  
You can change display level at any time, even during program-  
ming. All the program data which have been confirmed up to  
that point with the O.K.-key are stored.  
(3rd every 3rd day / 2nd every 2nd day).  
% Run-  
Time  
Budget function: the watering time of all watering  
programs can be reduced centrally in intervals of  
10% from 100% to 0%.  
D
E
ERROR  
Error message for the special function  
if watering programs overlap.  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect Water Computer:  
The Water Computer is fitted with a sleeve nut  
for taps with  
allows the  
L
4. Putting Your Water Computer into Operation  
G1(33.3 mm) thread. The adaptor supplied  
K
Water Computer to be connected to taps with a G 3/4thread  
(26.5 mm).  
This Water Computer must only be powered by a 9V alkaline  
manganese (alkaline) battery type IEC 6LR61.  
Insert battery:  
K
L
Connect Water Computer to water tap with G1(33.3 mm)  
thread:  
1. Press unlock button and pull control  
H
unit  
out of the Water Computer housing.  
I
I
1. Screw sleeve nut  
of the Water Computer on to the tap  
L
2. Insert battery  
compartment.  
into battery  
J
thread by hand (do not use pliers).  
2. Screw tap connector on to the Water Computer.  
M
Ensure that the battery polarity P is  
correct.  
The display shows all the LCD-symbols  
for 2 seconds and then moves to the  
time/day of week level.  
H
Connect Water Computer to tap with G 3/4” (26.5 mm) thread:  
1. Screw adaptor on to the tap manually (do not use pliers).  
K
2. Screw sleeve nut  
of the Water Computer on to the adaptor  
L
thread  
by hand (do not use pliers).  
K
3. Re-insert control unit  
in housing.  
I
D
z
M
3. Screw tap connector  
on to the Water Computer.  
M
Programming aid:  
v Stick the self-adhesive programming  
aid on the inside of the display cover D .  
The display cover can be folded up to protect the display against  
the weather.  
Before you start entering the watering data in the computer  
we recommend that you write the data on one of the watering  
plans in the appendix to maintain more of an overview.  
Compile watering plan:  
P
z
J
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Example:  
Fit anti-theft device  
(optional):  
To secure your Water Computer against theft, you can obtain  
the GARDENA anti-theft device art. no. 1815-00.791.00 from  
GARDENA Service.  
Program  
Starting time  
Watering time  
Watering days / Watering cycles  
Mo Tu We Th Fr Sa So 2nd 3rd  
PROG  
START TIME  
RUN TIME  
1. Screw clamp  
Computer.  
with screw  
firmly to the back of the Water  
O
P
P
1
2
3
4
5
6
7:30  
19:00  
22:30  
4:00  
0:30  
0:20  
1:10  
0:15  
X
X
X
2. Use clamp e.g. for fixing a chain.  
X
X
It is no longer possible to remove the screw after it has been  
screwed in.  
X
X
X
X
O
5. Programming  
Connect soil moisture  
or rain sensor (optional):  
In addition to time-based watering, it is also possible to include  
the soil moisture or rain sensor in the watering programs.  
The control unit  
can be removed from the housing for pro-  
I
gramming by pressing the unlock button  
can be undertaken whilst you are moving around (see 4.  
Putting Your Water Computer into Operation “Insert battery” ).  
and programming  
H
If the soil is moist enough, the program will be stopped, or a  
program will be prevented from starting. Manual operation via  
man. On/Off is unaffected by this.  
Set current time  
and day of week:  
N
1. Place soil moisture sensor in the watered area  
– or –  
1. Press Menu-key (not necessary if the battery has just been  
place rain sensor (with extension cable if necessary)  
outside the watered area.  
inserted).  
2. Insert the sensor in the sensor connection  
Computer.  
of the Water  
The hours display and time flash.  
N
1.  
10  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Set the time in hours with the -key  
1. Press Menu-key twice  
(example: 9 hours) and confirm with the O.K.-key.  
(not necessary if the current time and day of the week  
has been entered).  
time and the minutes display flash.  
Program memory setting 1 flashes.  
2.  
3.  
1.  
2.  
3.  
4.  
3. Set the time in minutes with the -key  
2. Only if the Automatic Water Distributor is used:  
(example: 30 minutes) and confirm with the O.K.-key.  
Select special-function with the -key and confirm with  
the O.K.-key (continue with step 4).  
time and the day of the week display flash.  
Program memory setting 1 is selected automatically,  
start time and the hours section flash on the display.  
4. Set the day of the week with the -key  
(example: Sa Saturday) and confirm with the O.K.-key.  
3. Select program memory setting with the -key  
(example: Prog. 3 program 3) and confirm with the  
O.K.-key.  
The display moves to the message Insert watering programs  
and program memory setting 1 flashes.  
4.  
start time and the hours section flash on the display.  
Enter watering programs:  
You must reset your Water Computer before selecting the  
special function (see 6. Automatic Water Distributor).  
4. Set the hours for starting the watering time with the -key  
(example: 6 hours) and confirm with the O.K.-key.  
v Reset: Keep -key and O.K.-key pressed simultaneous  
for 2 seconds.  
start time and the minutes section flash on the display.  
Up to 6 watering programs can be inserted – or –  
the special function can be selected.  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Set the minutes for starting the watering time with the -key  
(example: 20 minutes) and confirm with the O.K.-key.  
8. (b) Select respective watering days with the -key  
(example: Mo, Fr Monday and Friday) and confirm  
with the O.K.-key. Press -key until the over Su  
disappears.  
RUN TIME and the hours for the watering time flash on the  
display.  
The display returns to step 3 and the next highest program  
memory setting flashes.  
5.  
6.  
7.  
8. (b)  
6. Set the hours for the watering time with the -key  
(example: 0 hours) and confirm with the O.K.-key.  
V
If you would like to water your garden every day, press  
the OK button to confirm each day one after another.  
RUN TIME and minutes for the watering time flash on the  
display.  
When the program has been created for program memory setting 6,  
the display moves to the message % Run-Time / Prog. Off.  
Activate watering programs:  
You must select the Run-Time percentage you wish to activate  
before the watering programs can run.  
7. Set watering time minutes with the -key  
(example: 10 minutes) and confirm with the O.K.-key.  
9. Press Menu-key 3 times (not necessary if the program has  
just been compiled for program memory setting 6).  
Watering cycle 3rd flashes on the display.  
10. Select the percentage (see Budget Function) for the pro-  
grammed watering time using the key (e.g. 60 % Run-Time)  
and then confirm your selection by pressing the O.K. key.  
The display moves to the normal display.  
8. (a) Select watering cycle with the -key (example: 2nd  
and confirm with the O.K.-key  
)
10.  
(2nd /3rd: watering every 2nd day / 3rd day).  
Programming the Water Computer has now been completed,  
i.e. the built-in valve opens/closes entirely automatically and  
thus undertakes watering at the programmed times.  
The display returns to step 3 and the next highest  
program memory setting flashes.  
8 (a)  
– or –  
14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programmed watering time  
Budget-Function (%Run-Time):  
1. Press man. On/Off-key to open the valve manually  
(or to close an open valve).  
RUN TIME and the watering time in minutes (set to 30 minutes  
in the works) flash for 5 seconds on the display.  
The times of all stored watering programmes can be reduced cen-  
trally in intervals of 10%, from 100% down to 10%, without having  
to change each interval programme. This is ideal if you wish to  
water your garden less in the Autumn than in the Summer.  
1.  
2.  
2. Whilst the watering time in minutes is flashing, the watering  
:
duration can be modified with the -key (between 0 00  
10 - 100 % Run-Time = Watering program active  
:
and 0 59) (example: 10 minutes).  
Watering program deactivated  
0
Prog. Off  
= Watering program inactive  
The valve is opened.  
3. Press man. On/Off-key to close the valve early.  
Note: If you change the watering time percentage, your Water  
Computer will still display the watering time you originally pro-  
grammed for the individual watering programs.  
The valve is closed.  
The amended manual opening period is stored, i.e. each time  
the valve is opened manually in future the modified opening  
period is preset. If the manual opening period is amended to  
Read/ modify  
watering programs:  
If a program has already been set on one of the 6 program  
memory settings, this can be modified without having to compile  
it from the beginning again.  
:
0 00, the valve is closed and also remains closed after the  
man. On/Off-key is pressed (child lock).  
1. Press Menu-key twice.  
Program memory setting 1 flashes.  
If the valve has been opened manually and a programmed start  
of a watering period overlaps the manual opening period, the  
programmed starting time is suppressed.  
2. Press O.K.-key to move to the next program step – or –  
modify program data with the -key and confirm with the  
O.K.-key.  
Example: The valve is opened at 9.00 a.m. manually, the  
opening period is 30 minutes. A program with a start time  
(START TIME) between 9.00 and 9.30 a.m. will not be under-  
taken in this case.  
Manual operation:  
The valve can be opened or closed manually at any time.  
A program-controlled open valve can also be closed early with-  
out changing the program data (start time, watering duration  
and watering days).  
16  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reset  
The factory settings are restored.  
6. Automatic Water Distributor (optional)  
v Press -key and O.K.-key simultaneously for 2 seconds.  
Connecting the GARDENA Automatic Water Distributor  
(Art. No. 1198) allows you to control up to 6 watering lines with  
the Water Computer C 1060 profi.  
Each of the 6 watering lines can only be actuated once a day.  
This is ideal where there is an insufficient amount of water or  
where individual areas of the garden have varying water require-  
ments. It allows all watering lines to be operated one after  
another.  
Using the special function, your Water Computer C 1060 profi is  
able to take into account the special requirements of the Automatic  
Water Distributor, when programming.  
Function  
All the LCD symbols are displayed for 2 seconds and the  
display moves to the normal display.  
All the program data are set to zero.  
The manual watering period is set to 0 30 again.  
:
The time and day of the week are retained.  
Important notes:  
If no entry is made during programming for a period of more  
than 60 seconds, the normal display reappears.  
Programming  
With overlapping programs and identical watering days, the  
1st watering starting time has priority and other programs are  
not initiated.  
Special function  
If program data have already been inserted beforehand, a RESET  
must be undertaken before the special function can be set.  
v Keep -key and O.K.-key pressed simultaneously for  
Example:  
2 seconds.  
To ensure the Automatic Water Distributor switches safely there  
must be at least a 30 minute break between the programs entered  
in the Water Computer.  
When you have confirmed the special function with O.K. and  
have entered the data for the first program (see 5. Programming)  
all the programmes which follow will be pre-programmed auto-  
matically.  
Program  
Starting time  
Watering time  
Watering days / Watering cycles  
Mo Tu We Th Fr Sa So 2nd 3rd  
PROG  
START TIME  
4:00  
RUN TIME  
1
0:40  
1:00  
X
X
X
2
4:30  
The first program is run on Monday, the 2nd program is cancelled.  
18  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The pre-programming takes into consideration the 30 minute  
break required between the programs as well as a minimum  
watering time of 30 seconds (display: 1 min.).  
This watering time is required to allow the Automatic Water  
Distributor to switch to the next outlet and to ensure that the  
order of the watering programs to the appropriate watering  
line is retained.  
By briefly opening the water flow the outlets on the Automatic  
Water Distributor are switched further so that when the watering  
programs are reactivated (% Run-Time) the original order of the  
outlets for the required watering program is retained.  
Soil Moisture Sensor /  
Rain Sensor  
When using the Water Computer C 1060 prof together  
with the Automatic Water Distributor, Soil Moisture Sensor  
(Art. No. 1187) or Rain Sensor electronic (Art. No. 1189)  
please note the following:  
The watering days entered for the watering program are valid  
for all other watering programs.  
If the special function is activated and the Soil Moisture or  
Rain Sensor indicates sufficient moisture, watering is interrupted.  
The watering time of following watering programs is shortened  
to 30 seconds (display: 1 min.) until the Soil Moisture / Rain  
Sensor allows the watering programs to be resumed. The water-  
ing time originally entered then begins.  
Error message (ERROR)  
You can alter the watering starting times and watering times  
pre-programmed by the Water Computer to meet your personal  
requirements. However, if you do not take into account the break  
times mentioned above, any changes you make are not accepted  
and an error message appears on the display (ERROR).  
Since it is very easy for watering times to overlap slightly, espe-  
cially when the beginnings and ends of programs are very close  
together, it is sensible to RESET the Water Computer and to  
re-enter the watering data to prevent an error message appearing.  
Shortening the watering time when the soil is sufficiently moist  
ensures that the automatic water distributor is switched to the  
next outlet and therefore ensures that the correct order of the  
watering program for the respective distributor outlet is retained.  
On/Off Prog.  
If the watering programs are switched off after you have con-  
firmed the special function (status indicator on Off Prog.) all the  
programs which begin in this time are shortened to the minimum  
watering time of 30 seconds (display: 1 min.) This ensures that  
the order of the watering programs to the appropriate outlet of  
the Automatic Water Distributor is retained.  
20  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fault  
Possible Cause  
Remedy  
7. Cleaning  
No display appears  
Temperature on the display  
is higher than 60°C.  
Display appears after  
temperature has dropped.  
v Check function by operating  
manually. (man. On/Off).  
The filter should be checked regularly and cleaned when  
necessary.  
Clean filter:  
1. Unscrew sleeve nut  
of the Water Computer by hand  
L
L
from the tap thread (do not use pliers).  
Programs cannot be  
entered  
The current time and the day  
of the week were not entered  
completely.  
v Enter time and day of week  
(see 5. Programming).  
2. Remove filter from sleeve nut and clean.  
L
3. Screw sleeve nut  
of the Water Computer back on to the  
L
thread of the tap by hand (do not use pliers).  
Manual opening via the  
man. On/Off-key is not  
possible  
Low battery power, Batt.  
indicator flashes  
v Insert new (alkaline) battery  
Manual watering period is set  
v Set manual watering period  
:
to 0 00.  
to a figure greater than  
:
0 00 (see 5. Programming).  
Tap turned off.  
v Turn tap on.  
8. Trouble-Shooting  
Watering program is not  
being undertaken  
(no watering)  
Watering program has not  
been entered completely.  
v Read off watering program  
and modify if necessary.  
Fault  
Possible Cause  
Remedy  
Programs deactivated  
v Activate program  
(Prog. Off).  
(% Run-Time).  
No display appears  
Battery inserted incorrectly.  
v Check polarity markings  
match (+/–).  
Program entry/modification  
during or just before the  
start pulse.  
v Make program entry/  
modification outside the  
programmed start times.  
Flat battery.  
v Insert new (alkaline) battery.  
v Check function by operating  
manually (man. On/Off).  
22  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fault  
Possible Cause  
Remedy  
9. Putting Your Water Computer out of Operation  
Watering program is not  
being undertaken  
(no watering)  
Valve was opened manually  
previously.  
v Avoid possible program  
overlaps.  
1. Press Menu-key 3 times, select Prog. Off with the -key  
Over-wintering /  
storage:  
and confirm with the O.K.-key.  
Tap turned off.  
v Turn on tap.  
The watering programs are deleted.  
Program overlap  
(1st watering start time has  
priority).  
v Enter new watering  
2. Store your Water Computer in a dry place where it is protected  
from frost.  
program without overlaps.  
Please return flat batteries to a GARDENA dealer or dispose  
of them properly at your nearest recycling centre. Only dispose  
of batteries when they are flat.  
Soil moisture or rain sensor  
reports sufficient moisture.  
v If dry, check setting/  
location of soil moisture/  
rain sensor.  
Batt. indicator flashes because  
battery is almost flat.  
v Insert new (alkaline) battery  
10. Accessories  
Water Computer does  
not close  
Minimum quantity of water  
drawn is less than 20 l/h.  
v Connect more drip heads  
Automatic control with:  
GARDENA Soil Moisture Sensor  
GARDENA Rain Sensor electronic  
GARDENA Automatic Water Distributor  
Art. No. 1187  
Art. No. 1189  
Art. No. 1198  
If you have any other problems with your Water Computer, please contact GARDENA Service.  
24  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. Technical Data  
12. Service  
Warranty  
Min. /max. operating pressure:  
Flow medium:  
0,5 bar / 12 bar  
Clear fresh water  
40°C  
GARDENA guarantees this product for 2 years (from date of  
purchase). This guarantee covers all serious defects of the unit  
that can be proved to be material or manufacturing faults.  
Max. medium temperature:  
Under warranty we will either replace the unit or repair it free  
of charge if the following conditions apply:  
Number of program-controlled  
watering cycles per day:  
Up to 6  
The unit must have been handled properly and in keeping  
with the requirements of the operating instructions.  
Watering duration per program:  
Battery required:  
1 min. to 9 hours 59 min.  
Neither the purchaser or a non-authorised third party have  
attempted to repair the unit.  
1 × 9V alkaline manganese (alkaline) battery  
type IEC 6LR61  
Damage caused by frost is not covered by the warranty.  
Operating time of the battery  
approx. 1 year  
This manufacturer’s guarantee does not affect the user’s existing  
warranty claims against the dealer/seller.  
If you have any problems with your Water Computer, please  
contact our Customer Service or return the defective unit to-  
gether with a short description of the problem directly to one of  
the GARDENA Service Centres listed on the back of this leaflet.  
26  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Liability  
Product Liability  
G
f
We expressly point out that, in accordance with the product liability law, we are not liable for any damage  
caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts  
or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an  
authorised specialist. The same applies to spare parts and accessories.  
Painotamme tuotevastuulain mukaisesti erityisesti sitä seikkaa, että emme vastaa elektroniselle vesiajas-  
timelle aiheutuneista tai sen aiheuttamasta vahingoista, mikäli ne ovat aiheutuneet epäpätevän korjauksen  
takia, mikäli elektroniseen vesiajastimeen on vaihdettu osia, jotka eivät ole alkuperäisiä GARDENA-osia tai  
meidän hyväksymiä osia tai mikäli korjauksen on tehnyt jokin muu kuin GARDENA-huolto tai valtuutettu  
huolto. Sama koskee myös lisälaitteita ja -varusteita.  
Produktansvar  
S
N
Tillverkaren är inte ansvarig för skada som orsakats av produkten om skadan beror på att produkten har  
reparerats felaktigt eller om, vid reparation eller utbyte, andra än Original GARDENA reservdelar har an-  
vänts. Samma sak gäller för kompletteringsdelar och tillbehör.  
EU Certificate of Conformity  
The undersigned GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, hereby certifies that, when leaving  
our factory, the unit indicated below is in accordance with the harmonised EU guidelines, EU standards of safety and product  
specific standards. This certificate becomes void if the unit is modified without our approval.  
G
S
N
Productaansprakelijkheid  
Wij wijzen er nadrukkelijk op, dat wij op grond van de wet aansprakelijkheid voor producten niet aanspra-  
kelijk zijn voor schade ontstaan door onze apparaten, indien deze door onvakkundige reparatie veroorzaakt  
zijn, of er bij het uitwisselen van onderdelen geen gebruik gemaakt werd van onze originele GARDENA  
onderdelen of door ons vrijgegeven onderdelen en de reparatie niet door de GARDENA technische dienst  
of de bevoegde vakman uitgevoerd werd. Ditzelfde geldt voor extra-onderdelen en accessoires.  
EU Tillverkarintyg  
Undertecknad firma GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, intygar härmed att nedan nämnda  
produkter överensstämmer med EU:s direktiv, EU:s säkerhetsstandard och produktspecifikation. Detta intyg upphör att gälla  
om produkten ändras utan vårt tillstånd.  
Produkthaftung  
D
EU-overeenstemmingsverklaring  
Wir weisen ausdrücklich darauf hin, dass wir nach dem Produkthaftungsgesetz nicht für durch unsere  
Geräte hervorgerufene Schäden einzustehen haben, sofern diese durch unsachgemäße Reparatur verur-  
sacht oder bei einem Teileaustausch nicht unsere Original GARDENA Teile oder von uns freigegebene  
Teile verwendet werden und die Reparatur nicht vom GARDENA Service oder dem autorisierten Fachmann  
durchgeführt wird. Entsprechendes gilt für Ergänzungsteile und Zubehör.  
Ondergetekende GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, bevestigt, dat het volgende ge-  
noemde apparaat in de door ons in de handel gebrachte uitvoering voldoet aan de eis van, en in overeenstemming is met  
de EU-richtlijnen, de EU-veiligheidsstandaard en de voor het product specifieke standaard. Bij een niet met ons afgestemde  
verandering aan het apparaat verliest deze verklaring haar geldigheid.  
EU-Konformitätserklärung MaschinenVerordnung (9. GSGVO) / EMVG / Niedersp. RL  
D
Der Unterzeichnete GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, bestätigt, dass das nach-  
folgend bezeichnete Gerät in der von uns in Verkehr gebrachten Ausführung die Anforderungen der harmonisierten  
EU-Richtlinien, EU-Sicherheitsstandards und produktspezifischen Standards erfüllt. Bei einer nicht mit uns abgestimmten  
Änderung des Gerätes verliert diese Erklärung ihre Gültigkeit.  
134  
135  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROG  
START TIME  
RUN TIME  
Mo Tu We Th Fr Sa So 2nd 3rd  
EU-Vakuustodistus  
f
Allekirjoittanut, GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, vahvistaa, että lähtiessään tehtaalta ko.  
tuote (tuotteet) on valmistettu EU-ohjeiden, EU-turvallisuus – ja tuote-erittelystandardien mukaisesti. Tämä vakuus mitätöityy,  
mikäli tuotetta (tuotteita) muutetaan ilman hyväksyntäämme.  
1
2
3
4
5
6
Description of the unit:  
Produktbeskrivning:  
Omschrijving van het apparaat:  
Bezeichnung des Gerätes:  
EU-direktiivit:  
Water Computer  
Type:  
Type:  
Typ:  
Typ :  
Tyyppi:  
Art. No.:  
Art.nr. :  
Art. nr.:  
Art.-Nr.:  
art.-nro  
Bevattningscomputer  
Besproeiingscomputer  
Bewässerungscomputer  
Kasteluohjain  
C 1060  
profi  
1815  
1998  
EU directives:  
EU direktiv:  
EU-richtlijnen:  
EU-Richtlinien:  
EU-direktiivit:  
Year of CE marking:  
CE-Märkningsår:  
Installatiejaar van de CE-aanduiding:  
Anbringungsjahr der CE-Kennzeichnung:  
CE-hyväksyntä vuosi:  
89/336/EC  
93/68/EC  
PROG  
START TIME  
RUN TIME  
Mo Tu We Th Fr Sa So 2nd 3rd  
1
2
3
4
5
6
Thomas Heinl  
Ulm, 17.07.1998  
Ulm, 1998.07.17.  
Ulm, 17-07-1998  
Ulm, 17.07.1998  
Ulm, 17.07.1998  
Technical Dept. Manager  
Technical Director  
Hoofd technische dienst  
Technische Leitung  
Tekn. osaston päällikkö  
136  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Deutschland  
Brazil  
RGS Comercial Ltda  
Av. Marginal do  
Rio Pinheiros, 5200  
Edificio Montreal  
Bloco e -Térreo  
Cyprus  
Great Britain  
Italy  
New Zealand  
NYLEX New Zealand Limited  
Private Bag 94001  
South Auckland Mail Centre  
10 Offenhauser Drive  
East Tamaki, Manukau  
GARDENA  
FARMOKIPIKI LTD  
P.O. Box 7098  
74, Digeni Akrita Ave.  
1641 Nicosia  
GARDENA UK Ltd.  
27-28 Brenkley Way  
Blezard Business Park  
Seaton Burn  
GARDENA Italia S.p.A.  
Via Donizetti 22  
20020 Lainate (Mi)  
International GmbH  
Service Center  
Hans-Lorenser-Straße 40  
D-89079 Ulm  
Produktfragen: (0731) 490-246  
Reparaturen: (0731) 490-290  
Japan  
Newcastle upon Tyne NE13 6DS  
Czech Republic  
GARDENA spol. s.r.o.  
Шнpskб 20a, и.p. 1153  
62700 Brno  
KAKUDAI Mfg. Co. Ltd.  
1-4-4, Itachibori Nishi-ku  
Osaka 550  
05693-000 Sao Paulo - SP  
Greece  
Agrokip  
G. Psomadopoulos & Co.  
33 A, Ifestou str. – 194 00  
Industrial Area Koropi  
Athens  
Norway  
Bulgaria  
GARDENA Norge A/S  
Postboks 214  
2013 Skjetten  
Argentina  
Argensem S.A.  
Calle Colonia Japonesa s/n  
(1625) Loma Verde  
Buenos Aires  
DENEX LTD.  
2 Luis Ahalier Str.  
7th floor  
Luxembourg  
Magasins Jules Neuberg  
Grand Rue 30  
Case Postale No. 12  
Luxembourg 2010  
Denmark  
GARDENA Danmark A/S  
Naverland 8  
Poland  
Sofia 1404  
GARDENA Polska Sp. z o.o.  
Szymanóv 9 d  
Canada  
2600 Glostrup  
Hungary  
Australia  
GARDENA Canada Ltd.  
100 Summerlea Road  
Brampton, Ontario  
Canada L6T 4X3  
GARDENA Magyarország Kft.  
Késmárk utca 22  
1158 Budapest  
05-532 Baniocha  
Finland  
Habitec Oy  
Martinkyläntie 52  
01720 Vantaa  
Netherlands  
NYLEX Consumer Division  
76-88 Mills Road  
P.O. Box 722  
GARDENA Nederland B.V.  
Postbus 50176  
Portugal  
GARDENA Portugal Lda.  
Recta da Granja do Marquês  
Edif. GARDENA  
Iceland  
Heimilistaeki hf  
Saetun 8  
P.O. Box 5340  
125 Reykjavik  
1305 AD ALMERE  
Braeside 3195  
Melbourne, Victoria  
Chile  
France  
Neth. Antilles  
Antonio Martinic Y CIA. LTDA.  
Gilberto Fuenzalida 185 Loc.  
Las Condes  
Algueirão  
2725-596 Mem Martins  
GARDENA France  
Service Après-Vente  
BP 50080  
Jonka Enterprises N.V.  
Sta. Rosa Weg 196  
P.O. Box 8200  
Austria  
GARDENA Österreich  
Ges. m.b.H.  
Stettnerweg 11-15  
2100 Korneuburg  
Russia / Россия  
АО АМИДА ТТЦ  
ул. Моcфилмовcкая 66  
117330 Моcква  
Santiago de Chile  
95948 ROISSY CDG Cedex  
Republic of Ireland  
Michael McLoughlin & Sons  
Hardware Limited  
Long Mile Road  
Curaçao  
Costa Rica  
Compania Exim  
Euroiberoamericana S.A.  
Av. 12 bis Calle 16 y 18  
Bodegas Keith y Ramirez  
San José  
Belgium  
MARKT (Belgium) NV/SA  
Sterrebeekstraat 163  
1930 Zaventem  
Dublin 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Singapore  
Spain  
Ukraine / Украина  
АОЗТ АЛЬЦЕСТ  
ул. Гайдара 50  
г. Киев 01033  
Hy - Ray Enterprises  
Block 1002 Toa Payoh  
Industrial Park  
GARDENA IBÉRICA S.L.U.  
C/ Basauri, nº 6  
La Florida  
#07-1433/1435/1451  
Singapore 319074  
28023 Madrid  
Turkey  
Sweden  
GARDENA/Dost Diþ Ticaret  
Mümessillik A.Þ.  
Yeþilbaðlar Mah. Baþkent  
Cad. No. 26  
Slowenia / Croatia  
Silk d.o.o. Trgovina  
Brodiљиe 15  
GARDENA Norden AB  
Box 9003  
20039 Malmö  
1236 Trzin  
Pendik - Ýstanbul  
Switzerland  
GARDENA AG  
Bitziberg 1  
South Africa  
GARDENA  
South Africa (Pty.) Ltd.  
P.O. Box 11534  
Vorna Valley 1686  
USA  
GARDENA  
3085 Shawnee Drive  
Winchester, VA 22604  
8184 Bachenbülach  
1815-28.960.04/0041  
GARDENA Manufacturing GmbH  
D-89070 Ulm  
©
http://www.gardena.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ETA Systems Yard Vacuum ETA C15D User Manual
Extron electronic Switch DTP DVI 230 User Manual
Extron electronic TV Mount SI 26 User Manual
Fluke Work Light 39 User Manual
Frigidaire Air Conditioner FRA123CT1 User Manual
FUNAI CRT Television ST27S3 User Manual
Fundex Games Games Wildfire User Manual
Gas Fired Products Electric Heater LTS 100 User Manual
GE Ice Maker WR49X10180 User Manual
Gigabyte Computer Hardware 7VT600 RZ User Manual