Hybrid Flex Inverter System
Dual, Tri and Quad Zone Mix &ꢀMatch Flexibility
Includes RLS2 Designer Series Indoor Models
Mini-Split Air Conditioners and Heat Pumps
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ
Use mini-splits just about any place that requires comfort!
Older homes
l
New construction homes
l
Schools
Restaurants
Car washes Convenience stores
Fire houses Police stations Oil rigs
Sunrooms and additions Warehouses Nursing homes
ATM vestibules Small offices...
l
Places of worship
Hospitals and medical facilities
Hotels and motels
Fast food chains
l
l
Computer rooms
l
l
l
l
l
l
Bars
l
l
l
Download from Www.Somanuals.com. All Manuals Search And Download.
RLS2 Designer Series Compatibility
Wall Mounted ASU9RLS2, ASU12RLS2, ASU15RLS2
Fujitsu’s indoor RLS2 models are now compatible with outdoor multi-
zone units so contractors can choose between different wall mounted
styles as well as different evaporator styles (wall mounted, compact
cassette or compact duct).
Features:
l Sleek chassis design
l Energy Saving Program (ESP)
Allowable Combinations
for AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ
52 Combinations Based on BTU
Over 597 Combinations Based on Indoor Type and BTU
ARU9RLF, ARU12RLF,
ARU18RLF, ARU24RLF
ASU7RLF, ASU9RLF,
ASU9RLS2, ASU12RLF,
ASU12RLS2, ASU15RLS2,
ASU18RLF, ASU24RLF
AUU9RLF
AUU12RLF
AUU18RLF
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ
7,000
9,000
12,000
18,000
24,000
15,000
BTUꢀCapacity
Allowed "Connectable Capacity" combinations between 100 and 130%
=
AOU18RLXFZ
AOU36RLXFZ
AOU36RLXFZ
12 12 15
7
7
7
9
14
16
19
18
21
39
28
30
33
36
39
32
35
38
38
34
37
36
18*18*
7
36
29
32
38
28
31
34
31
34
37
27
30
33
37
33
36
39
36
7
7
7
7
7
7
7
7
7
7
7
9
7
7
7
7
7
7
7
7
7
7
7
9
7 15
-
-
7 12
7
7
7
7
7
7 18
9
9
7 12
7 24
9 12
9 15
9 18
9 12
7 15
-
-
AOU24RLXFZ
-
7 18**
7
7
7
9
14
16
19
22
25
18
21
24
27
24
27
21
23
26
25
27
9
9
-
-
9 12
9 15
7 12 12
7 12 15
7 12 18
-
7 12
7 15
7 18
7 12 12
9
9
9
9
9
9
9
9
9
9
9
-
-
9
9
-
9 12
9 12
9 15
9 18
9 12
9 15
9 18
12 12
12 15
9
9
9 12 12
9 12 15
9 12 18
12 12 12
Remember: These systems
do not require branch boxes
or separation tube assemblies.
7
7
7
7
9
7
7
7
9
7 12
9
9
9
9
*The optional kit “K9FZ1818 (UTP-MU36A2)” is necessary for dual zone system “18+18”. **Wall mounted type ASU18RLF can not be connected in this
combination. “-” represents available circuit for future expansion when connecting this combination.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Multi-Zone Outdoor Units 18, 24 and 36,000 BTUs
AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ
AOU
AOU
AOU
AOU
18RLXFZ
24RLXFZ 36RLXFZ 36RLXFZ
18+18ꢀCombo1
ASU18+ASU18
Heat Pump
ASU9+ASU9
Heat Pump
ASU9+ASU7+ASU7
Heat Pump
ASU9 x 4
1
2
2 to 3
3 to 4
2
Connectable Indoor Unit Number
Connectable Unit Capacity Class BTU/h
Rated Capacity Cooling/Heating BTU/h
2
2
2
1
14 to 21,000 14 to 27,000
27 to 39,000
36,000
18,000/22,000 22,000/24,000 35,200/36,400 31,600/35,800
14 to 115
(-10 to 46)
5 to 75
(-15 to 24)
1.44/1.87
14 to 115
(-10 to 46)
5 to 75
(-15 to 24)
1.76/1.73
32 to 115
(0 to 46)
14 to 75
(-10 to 24)
4.00/3.00
50 to 115
(10 to 46)
14 to 75
(-10 to 24)
3.98/3.66
208-230/60/1
20.1
Clg. Operating Range °F(°C)
AOU36RLXFZ
Htg. Operating Range °F(°C)
AOU18, 24RLXFZ
Input Power: Clg/Htg Rated kW*
Voltage/Frequency/Phase
Current: Total Max. (A)
Minimum Circuit Ampacity (A)
Recommended Fuse Size (A)
Outdoor Fan Airflow CFM (Clg/Htg)
Fan: Type x Quantity
208-230/60/1 208-230/60/1 208-230/60/1
Compact Size
10.0
13
13.7
17
20.1
25
30
The compact size of the outdoor
units allows for many installation
opportunities.
25
30
25
25
1,795/1,619
1,942/1,942
2,119/2,237
Propeller x 1
53
2,119/2,237
Propeller x 1
53
Propeller x 1 Propeller x 1
49
49
98 (30)
164 (50)
82 (25)
49 (15)
16ꢀ(5)
51
52
98 (30)
164 (50)
82 (25)
49 (15)
16ꢀ(5)
Sound Pressure Level Cooling dB(A)
Sound Pressure Level Heating dB(A)
Pre-Charge Length Total Ft (m)
Max. Length Total Ft (m)
55
55
164 (50)
230 (70)
82 (25)
66 (20)
66 (20)
131 (40)
82 (25)
49 (15)
Max. Length Each Ft (m)
Min. Length Total Ft (m)
16 (5)
25 (7.5)
Min. Length Each Ft (m)
Max. Pipe Height Difference Between
Outdoor Unit & Farthest Indoor Ft (m)
Max. Pipe Height Difference
Between Indoor Units Ft (m)
Connection Method
49 (15)
49 (15)
49 (15)
49 (15)
33 (10)
Flare
33 (10)
33 (10)
33 (10)
Flare
24” minimum
clearance
required
Flare
Liq. 1/4 x 3
Suc. 1/2 x 1,
3/8 x 2
124 (56)
27-9/16
700
Flare
Liq. 1/4 x 4
Suc. 1/2 x 1,
3/8 x 3
149 (68)
32-11/16
830
Liq. 1/4 x 2
Suc. 3/8 x 2
Liq. 3/8 x 2
Suc. 1/2 x 2
Conn. Pipe Diameter Inch
1
Net Weight lbs. (kg)
Dimensions: Height Inch
119 (54)
27-9/16
700
149 (68)
32-11/16
830
mm
Width Inch
mm
DC Twin Rotary
35-7/16
900
35-7/16
900
35-7/16
900
35-7/16
900
Compressor
A high perform-
ance, low noise,
large capacity
DC twin rotary
compressor is
used.
Depth Inch
13
13
13
13
mm
330
330
330
330
Refrigerant
R410A
R410A
R410A
R410A
118+18 is the only 2 indoor unit (ASU, ARU or AUU) combination and requires K9FZ1818.
See Design &ꢀTechnicalꢀManual for allowed combinations within this connectable capacity range.
2
Nominal Capacities, SEER and HSPF Ratings
Data below is based on AHRI 210/240 non-ducted wall mounted models.
Cooling
Heating Capacity
Btu/h
Indoor Unit
Capacity
Btu/h
COP
Model
EER
SEER
HSPF
◦
◦
◦
◦
Type
Non-Ducted
Ducted
Combination
ASU9+ASU9
95 F
47 F
17 F
47 F
18,000
18,000
18,000
12.50
12.10
12.30
18.0
16.0
17.0
22,000
22,000
22,000
13,900
13,900
13,900
3.44
3.52
3.48
9.3
9.0
9.2
-
-
Mixed
AOU18RLXFZ
ASU7+ASU12 and
ASU9+ASU12
Specific
18,000
12.50
18.0
22,000
13,900
3.67
9.0
Non-Ducted
Ducted
ASU9+ASU7+ASU7
22,000
22,000
22,000
35,200
33,800
34,400
12.50
10.60
11.55
8.80
18.0
15.5
16.8
16.0
14.5
15.3
24,000
24,000
24,000
36,400
36,400
36,400
14,100
14,100
14,100
22,000
21,200
21,600
4.04
3.42
3.74
3.56
3.08
3.32
9.5
9.0
9.3
9.4
8.7
9.1
AOU24RLXFZ
AOU36RLXFZ
-
-
-
-
-
Mixed
Non-Ducted
Ducted
8.10
Mixed
8.45
Yellow rows represent models that are ENERGY STAR® Qualified.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Wall Mounted 7, 9, 12, 18 and 24,000 BTUs
ASU7RLF, ASU9RLF, ASU9RLS2, ASU12RLF, ASU12RLS2, ASU15RLS2,
ASU18RLF, ASU24RLF
^
ASU9, 12, 15RLS2
Designer Series
ASU7, 9, 12RLF
ASU18, 24RLF
ASU7RLF
ASU9RLF ASU12RLF ASU18RLF ASU24RLFASU9RLS2 ASU12RLS2ASU15RLS2
Heat Pump
Heat Pump
Heat Pump
Heat Pump Heat Pump Heat Pump^ Heat Pump^
Heat Pump^
7,000
8,100
9,000
10,200
12,000
13,500
18,000
20,000
24,000
27,000
9,000
10,200
12,000
13,500
14,000
16,300
208-230/60/1
Clg 418 (710)
Htg 418 (710)
Clg 377 (640)
Htg 377 (640)
Clg 336 (570)
Htg 347 (590)
Clg 230 (390)
Htg 253 (430)
Nominal Cooling BTU/h*
Nominal Heating BTU/h*
Voltage/Frequency/Phase
208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Clg 330 (560)
Htg 330 (560)
Clg 294 (500)
Htg 294 (500)
Clg 253 (430)
Htg 253 (430)
Clg 353 (600)
Htg 353 (600)
Clg 306 (520)
Htg 306 (520)
Clg 253 (430)
Htg 253 (430)
Clg 388 (660)
Htg 388 (660)
Clg 330 (560)
Htg 330 (560)
Clg 265 (450)
Htg 277 (470)
Clg 542 (920) Clg 659 (1,120) Clg 353 (600)
Htg 542 (920) Htg 647 (1,100) Htg 353 (600)
Clg 388 (660)
Htg 388 (660)
Clg 353 (600)
Htg 353 (600)
Clg 312 (530)
Htg 312 (530)
Air Circ. C.F.M. (m3/h): Hi
Clg 436 (740)
Htg 436 (740) Htg 530 (900) Htg 324 (550)
Clg 365 (620) Clg 436 (740) Clg 277 (470)
Htg 365 (620) Htg 436 (740) Htg 277 (470)
Clg 324 (550) Clg 365 (620) Clg 194 (330)
Htg 324 (550) Htg 365 (620) Htg 194 (330)
Clg 530 (900)
Clg 324 (550)
Medium
Low
Clg 200 (340)
Htg 206 (350)
Clg 200 (340)
Htg 206 (350)
Clg 200 (340)
Htg 206 (350)
Clg 194 (330)
Htg 194 (330)
Quiet
Noise Level
dB(A) (Clg/Htg): Hi
Medium
36/36
37/37
40/40
43/44
49/48
36/36
37/37
41/41
32/32
29/29
25/25
33/33
29/29
25/25
36/36
30/31
25/25
37/37
33/33
31/31
42/42
37/37
33/33
32/32
28/28
21/21
34/34
31/31
21/21
36/36
33/34
25/27
Low
Quiet
Running Current
Rated (A):ꢀCooling
Heating
0.13
0.15
0.19
0.32
0.53
0.14
0.17
0.20
0.13
15
0.15
17
0.19
22
0.32
41
0.53
69
0.14
16
0.17
19
0.20
23
Power Use Rated (w):ꢀClg
Htg
15
17
22
41
69
16
19
23
Fan Speeds Stage
Air Direction: Horizontal
Vertical
4+auto
Manual
Auto
4+auto
Manual
Auto
4+auto
Manual
Auto
4+auto
Auto
Auto
4+auto
Auto
Auto
4+auto
Manual
Auto
4+auto
Manual
Auto
4+auto
Manual
Auto
Primary Air Filter
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Washable
Disposable
Disposable
Flare
Ion Deodorizing Filter
Apple-Catechin Filter
Connection Method
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)
Dims: Height Inch (mm)
Width Inch (mm)
suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4suc 5/8 dis 1/4suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4
18 (8)
18 (8)
18 (8)
31 (14)
31 (14)
21 (9.5)
21 (9.5)
21 (9.5)
11-1/8 (282)
11-1/8 (282)
11-1/8 (282)
11-1/16 (280) 11-1/16 (280) 11-1/16 (280) 12-5/8 (320) 12-5/8 (320)
31-1/16 (790) 31-1/16 (790) 31-1/16 (790) 39-1/4 (998) 39-1/4 (998) 34-1/4 (870)
13-1/4* (337*)
13-1/4* (337*)
13-1/4* (337*)
34-1/4 (870)
7-1/4 (185)
R410A
34-1/4 (870)
7-1/4 (185)
R410A
Depth Inch (mm)
8 (203)
R410A
8 (203)
R410A
8 (203)
R410A
9 (228)
R410A
9 (228)
R410A
7-1/4 (185)
R410A
Refrigerant
^Not compatible with outdoor unit AOU48RLXFZ.
*Height when front panel is open.
Standard Features
Built In Filtration
l
l
l
l
l
l
l
l
l
l
l
Wireless Remote Control*
Apple Catechin Filter
Ion Deodorizing Filter
Sleep Timer
Long-life+ Ion Deodorization Filter
The filter deodorizes by powerfully
decomposing absorbed odors using
the oxidizing and reducing effects of
ions generated by the ultra-fine-
particle ceramic.
Apple-Catechin Filter
Dust, mold spores and micro-
24-Hour Timer
organisms are absorbed onto the
filter by static electricity and growth
is inhibited and deactivated.
Dry Mode
Auto Louver: 4-Way**
Auto Mode
Minimum Heat Mode
Auto Restart/Reset
Power Diffuser**
+ The filter can be used for approximately 3 years if it is washed with water when dirty to restore it's surface action.
* Features vary by model and therefore standard
wireless remote controls should be used with the
models they are associated with.
5
**Feature of models ASU18, 24RLF only.
Download from Www.Somanuals.com. All Manuals Search And Download.
Compact Duct 9, 12, 18 and 24,000 BTUs
ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF
Compact Duct
Adaptable when ceiling cavity
is small and there is no slope
for drain.
ARU9, 12RLF
ARU18RLF
ARU24RLF
Traditional
ARU12RLF ARU18RLF ARU24RLF
ARU9RLF
Heat Pump
Heat Pump
Heat Pump
Heat Pump
Drain
Pump
Nominal Cooling BTU/h
Nominal Heating BTU/h
Voltage/Frequency/Phase
Recommended Static Pressure In. W. C.
Air Circ. C.F.M. (m3/h) Clg/Htg: Hi
9,000
10,200
208-230/60/1
0 ~ 0.36
353 (600)
324 (550)
294 (500)
265 (450)
28/28
12,000
13,500
208-230/60/1
0 ~ 0.36
383 (650)
353 (600)
324 (550)
283 (480)
29/29
18,000
20,000
208-230/60/1
0 ~ 0.36
554 (940)
518 (880)
483 (820)
442 (750)
32/33
24,000
27,000
13”
208-230/60/1
0 ~ 0.20
783 (1,330)
730 (1,240)
648 (1,100)
607 (1,030)
33/35
Compact Duct
Medium
Low
Quiet
9.4”
Noise Level dB(A) (Clg/Htg): Hi
27/26
28/28
31/32
32/34
Medium
26/25
25/24
27/27
26/24
30/31
29/29
30/32
29/29
Low
Quiet
Return Air-intake Choices
Running Current Rated (A):ꢀCooling
Heating
0.30
0.30
49
0.35
0.35
58
0.44
0.44
73
0.66
0.66
111
Bottom
Power Use Rated (W):ꢀCooling
Heating
Fan Speeds Stage
Air Filter
49
58
73
111
4 +ꢀAuto
Washable
Flare
4 +ꢀAuto
Washable
Flare
4 +ꢀAuto
Washable
Flare
4 +ꢀAuto
Washable
Flare
Back
Connection Method
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)
Standard Features
suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4 suc 5/8 dis 1/4
41 (19)
7-25/32 (198)
27-9/16 (700)
41 (19)
7-25/32 (198)
27-9/16 (700)
50 (23)
7-25/32 (198)
35-7/16 (900) 43-5/16 (1,100)
59 (27)
7-25/32 (198)
l
l
l
l
l
l
l
l
l
l
l
Dry Mode
Dimensions: Height Inch (mm)
Width Inch (mm)
Depth Inch (mm)
Supply Duct Flange
Dimensions: Height Inch (mm)
Width Inch (mm)
Weekly Timer
Sleep Timer*
24-HourꢀTimer*
Minimum Heat Mode*
Auto Mode
24-13/32 (620) 24-13/32 (620) 24-13/32 (620) 24-13/32 (620)
5-15/16 (151) 5-15/16 (151) 5-15/16 (151) 5-15/16 (151)
25-19/32 (650) 25-19/32 (650) 33-15/32 (850) 41-11/32 (1,050)
Quiet Mode
Depth Inch (mm)
3/4 (19)
3/4 (19)
3/4 (19)
3/4 (19)
Auto Restart/Reset
Auto Changeover
Condensate Pump
Fresh Air Intake
Return Duct Flange
Dimensions: Height Inch (mm)
Width Inch (mm)
6-27/32 (174)
6-27/32 (174)
6-27/32 (174)
6-27/32 (174)
22-19/32 (574) 22-19/32 (574) 30-15/32 (774) 38-11/32 (974)
Depth Inch (mm) 3/4ꢀ(19) (Flat)
Refrigerant
3/4ꢀ(19) (Flat)
R410A
3/4ꢀ(19) (Flat)
R410A
3/4ꢀ(19) (Flat)
R410A
R410A
*Available only with optional wireless
remote control.
Field Supplied Filters Used With Compact Duct Units
Compact Duct Units require field supplied filters. They can be installed
at the unit or for more convenient servicing, in filter grilles. The chart
to the right provides guidelines for determining filter sizes.
ARU
12RLF
353
ARU
18RLF
547
ARU
24RLF
806
ARU
9RLF
353
CFM
Typical Filter Size
Velocity, FPM
12 x 20
212
12 x 20
212
14 x 25
225
18 x 30
215
0.36
0.36
0.20
0.36
Unit External SP, in. W.C.
1" Fiberglass Filter
Filters are sized to keep velocities and
static pressure loss low. This will insure
sufficient static pressure is available for
ductwork, fittings and supply and return
grilles. lternative filter sizes with
0.04
0.32
0.04
0.32
0.04
0.16
SP Loss, in. W.C.
0.04
0.32
Available Static Pressure
1" MERV 8 Pleated Filter
SP Loss, in. W.C.
0.12
0.24
0.14
0.22
0.13
0.07
0.12
0.24
Available Static Pressure
2" MERV 8 Pleated Filter
equivalent face areas can be used.
After deducting filter loss, available
static pressure values are shown.
SP Loss, in. W.C.
0.07
0.29
0.08
0.28
0.07
0.13
0.07
0.29
Available Static Pressure
A fiberglass filter is shown in
blue to the left. A MERVꢀpleated
filter is shown in white.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Compact Cassettes 9, 12, and 18,000 BTUs
AUU9RLF, AUU12RLF, AUU18RLF
Easy Installation
Fits into a standard ceiling tile*.
Compact cassette and compact duct
models can be networked.
AUU12RLF AUU18RLF
AUU9RLF
Heat Pump
Heat Pump
Heat Pump
22.5”
22.5”
Nominal Cooling BTU/h
Nominal Heating BTU/h
9,000
12,000
13,500
18,000
20,000
10,200
Voltage/Frequency/Phase 208-230/60/1
208-230/60/1
208-230/60/1
318 (540)
Clg or Htg
359 (610)
Clg or Htg
441 (750) Clg
471 (800) Htg
Air Circ. C.F.M. (m3/h): Hi
288 (490)
312 (530)
Clg or Htg
277 (470)
Clg or Htg
241 (410)
Clg or Htg
359 (610) Clg
418 (710) Htg
306 (520) Clg
353 (600) Htg
241 (410) Clg
265 (450) Htg
Medium
*Dimensions of outer grille are 27-9/16” x 27-9/16”
and may overlap adjacent tiles.
Clg or Htg
259 (440)
Low
Clg or Htg
230 (390)
2-Stage Turbo Fan
Quiet
Clg or Htg
Air distribution is evenly spread across
the heat exchanger by the new 2 stage
turbo fan which produces two separate
airflow streams.
Noise Level dB(A) Clg/Htg: Hi
33/34
37/37
42/44
Medium
31/32
33/33
37/40
Low
Quiet
29/29
31/31
33/37
27/27
28/28
29/30
1-stage
Running Current Rated (A):ꢀCooling
Heating
0.15
0.19
0.30
0.15
0.19
0.30
2-stage
Power Use Rated/Max (W):ꢀClg
Heating
18
23
39
Heat exchange
efficiency:
Increased 20%
18
23
39
Fan Speeds Stage
Air Direction: Vertical
Air Filter
4+auto
Automatic
Washable
UTG-CCGF*
Flare
4+auto
Automatic
Washable
UTG-CCGF*
Flare
4+auto
Automatic
Washable
UTG-CCGF*
Flare
Standard Features
Front Grille
Connection Method
l
l
l
l
l
l
l
l
l
l
l
l
Sleep Timer
Dry Mode
Auto Louver: Up/ Down
Quiet Mode
Conn. Pipe Diameter Inch
suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4
Net Weight lbs. (kg)
Chassis Dim: Height Inch (mm)
Width Inch (mm)
33 (15)
33 (15)
33 (15)
Auto Restart/Reset
Auto Changeover
Remote Temperature Sensor
High Ceiling Mode
Condensate Pump
2-StageꢀTurbo Fan
Minimum Heat Mode+
Fresh Air Intake**
9-11/16 (245)
22-7/16 (570)
22-7/16 (570)
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
R410A
9-11/16 (245)
22-7/16 (570)
22-7/16 (570)
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
R410A
9-11/16 (245)
22-7/16 (570)
22-7/16 (570)
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
R410A
Depth Inch (mm)
Grille Dim: Height Inch (mm)
Width Inch (mm)
Depth Inch (mm)
Refrigerant
+ Available only with optional wireless remote control.
**Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4 – inch flex duct connection
and a field supplied duct booster fan. Fresh air maximum is 10% of unit High fan CFM. See
UTZ-VXAA Design and Technical Manual for fan static pressure requirements at Fresh Air Kit. Add
hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the height of the
indoor unit.
Fresh Air Kit**
UTZ-VXAA
Mixes room air then passes
through the heat exchanger.
* Compact Cassette Grille UTG-CCGF sold separately. Must order one with each compact cassette.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Optional Accessories
WiredꢀRemote
SimpleꢀRemote
Wireless Remote
Controller*
Controller
Controller
UTY-RNNUM^
UTY-RSNUM*
UTY-LNHUM
The wired remote controller with its unique
lock function and sleek design provides full
feature access to property managers,
building owners, and facility maintenance,
as well as providing basic comfort features
to tenants, employees, and teachers.
Suitable when only basic operations
are required for hotels, offices and
other places where there is frequent
arrival and departure of occupants.
For spaces where there is just no place to
mount the wired remote.
Dry Contact Wire Kit*
Interface Kit
Interface Kit
UTY-XWZX / UTY-XWZXZ5
UTY-TWBXF**
UTY-XCBXZ1**
Turns system on or off using a normally
closed circuit, for example in home
automation or BMS integration of only
On/Off operation, occupancy sensor or key
card switch or lead-lag control of other
heating/cooling.
Required to connect the ASU9RLS2,
ASU12RLS2 and ASU15RLS2 to Wired
Remote UTY-RNNUM, Dry Contact Wire
Kit UTY-XWZXZ5, and Simple Remote
Control UTY-RSNUM.
Required to connect ASU7RLF, 9RLF,
12RLF and ASU15RLS to Wired Remote
UTY-RNNUM, Dry Contact Wire Kit
UTY-XWZX, and Simple Remote
Control UTY-RSNUM.
Air Outlet
Fresh Air
High Humidity
Shutter Plate
Intake Kit
Insulation Kit
UTR-YDZB
UTZ-VXAA
UTZ-KXGC
Additional insulation for compact cassette
units, which may be needed when they
are installed in high humidity areas.
In a 3-way air flow configuration an Air
Outlet Shutter Plate kit is required.
Mixes room air then passes it through a
heat exchanger.
Receiver Unit
Remote Sensor
Compact Duct
18+18 Combo
UTY-LRHUM
UTY-XSZX
Connector Kit
Fittings Kit
UTD-ECS5A
K9FZ1818
Allows two 18,000 BTUꢀindoor
Comes with 5 sets of wires. Can
be used to turn unit on/off, wire
in float switch, AUX heater, turn
on an external device (Fan), or
show if the unit is running.
Wall mounted temperature
sensor for compact duct
models.
Includes a wireless remote
control.
units to be used on an outdoor
AOU36RLXFZ. Requires special
piping; limited to only 18,000
BTU models. Total BTU capacity
is limited to 35,800 BTU.
Compatibility:
Small Wall Mount
Designer Wall Mount
Large Wall Mount
Compact Cassette
9, 12, 18k BTU
Compact Duct
7,9,12k BTU / RLFꢀSeries
9,12, 15k BTU / RLS2ꢀSeries
18, 24k BTU
9, 12, 18, 24k BTU
^ Minimum Heat, Sleep Timer functions will be lost when the wired remote controller is installed.
Wall mounted ASU7, 9, and 12RLF require accessory interface kit (Part UTY-XCBXZ1) in order to connect this device to them. Wall mounted ASU9, 12,
*
and 15RLS2 require accessory interface kit (Part UTY-TWBXF) in order to connect this device to them.
** Internal thermosensor function in Wired Remote UTY-RNNUM is disabled when using this interface kit.
Fujitsu General America, Inc.
353 Route 46 West
The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon HFI logo and name is a
trademark of Fujitsu General America, Inc. Copyright © 2013 Fujitsu General America, Inc. Fujitsu’s
products are subject to continuous improvements. ꢀFujitsu reserves the right to modify product design,
specifications and information in this brochure without notice and without incurring any obligations.
PLEASE NOTE: Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased on
the Internet, from an online retailer or any similar e-tailing website, OR where the original factory serial
numbers of the display have been removed, defaced, or replaced in any way WILL NOT BE COVERED BY
WARRANTY.
Fairfield, NJ 07004
Toll Free: (888) 888-3424
Local: (973) 575-0380
Fax: (973) 836-0447
Email: [email protected]
Aꢀsubsidiary of
Fujitsu General Limited
Printed in the USA Rev. 3/13
Part #6-26-FG2038
Download from Www.Somanuals.com. All Manuals Search And Download.
|