| ® 16   Multimeter with Temperature   Instruction Sheet   P Read First: Safety Information   To ensure that the meter is used safely, follow these instructions:   • • Do not use the meter if the meter or test leads appear damaged, or if   you suspect that the meter is not operating properly.   Disconnect the live test lead before disconnecting the common test   lead.   • • When using the probes, keep your fingers behind the finger guards on   the probes.   Do not use the V•Check mode to measure voltages in circuits that   could be damaged by this mode’s low input impedance   (≅2 kΩ).   • • • Turn off power to the circuit under test before cutting, desoldering, or   breaking the circuit. Small amounts of current can be dangerous.   Do not apply more than 600V rms between a meter terminal and earth   ground.   Use caution when working with voltages above 60V dc or 30V ac rms.   Such voltages pose a shock hazard.   PN 643657 June 1997 Rev.2, 3/98   1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A.   Download from Www.Somanuals.com. All Manuals Search And Download.   AC and DC Voltage   Also refer to V•Check.   Volts AC   Input Impedance ≅5 MΩ   50 Hz to 400 Hz   Volts DC   Input Impedance ≅10 MΩ   MULTIMETER   MULTIMETER   16   16   AC   DC   4000 mV 4V 40V 400V 600V   OFF   OFF   V AC DC   V AC   / DC   / CAT   CAT   600V   600V   COM   + COM   + ip01i.eps   Resistance and Continuity eR   Turn off circuit power before testing. Also refer to V•Check.   Resistance   Continuity   16   MULTIMETER   MULTIMETER   MULTIMETER   16   16   Mk   OFF   OFF   OFF   V •Check   V •Check   V•Check   A Low Impedance   V•Check   A A CAT   CAT   CAT   TEMPERATURE   TEMPERATURE   TEMPERATURE   600V   600V   600V   COM   + COM   + COM   + 400Ω 4 kΩ 40 kΩ 400 kΩ 4 mΩ 40 mΩ   Detects shorts and opens ≥250 µS.   Short   Open   <25Ω   ip02i.eps   Download from Www.Somanuals.com. All Manuals Search And Download.   W V•Check   If a dc or ac voltage greater than about 4.5V is present across the inputs   when the meter is set to R, G, or e, the meter switches automatically   to dc or ac voltage mode (V•Check mode).   W Warning   Repetitive transients on a dc bus will cause V•Check to   select ac volts, even though a hazardous dc voltage may   be present. To avoid a misleading display and possible   electric shock, manually select the proper volts function   for measurements on these circuits.   When V•Check is activated, the meter has low input impedance (LoZ)   ≅2 kΩ. This load can alter the voltages in electronic control circuits. Do   not use V•Check to measure voltage in circuits that could be damaged by   a 2 kΩ load.   Hint: V•Check can be effectively used to eliminate “ghost” voltages.   Disable and re-enable V•Check   For and Ω,   If AC detected   If DC detected   MULTIMETER   16   , Disables V•Check and   locks meter in selected   mode.   Meter puts 2 kΩ   load on circuit.   2 sec   OFF   V •Check   A CAT   TEMPERATURE   600V   or   or   COM   + Re-enables   V•Check   or   ip09i.eps   Download from Www.Somanuals.com. All Manuals Search And Download.   Temperature   MULTIMETER   16   °F   °C   OFF   V•Check   A CAT   TEMPERATURE   600V   COM   + Vent   or   Pipe   80PK-1 Type K   Thermocouple   Probe   ip19f.eps   Note correct connector polarity.   To meet stated accuracy, the 80AK temperature adapter must be at the   same temperature as the meter. In addition, the 80AK and the 80PK-1   should be cleaned and lubricated regularly. Use any petroleum based   lubricant.   Warning   To avoid possible electric shock, DO NOT apply   thermocouple tip to any conductor that is greater than   30V AC, 42.4V pk, or 60V DC to earth.   Download from Www.Somanuals.com. All Manuals Search And Download.   Capacitance E   Turn off circuit power; then disconnect and discharge the capacitor before   measuring capacitance.   MULTIMETER   16   If the capacitor requires more   discharging, diSC is displayed   while the capacitor discharges.   OFF   V •Check   A CAT   TEMPERATURE   600V   COM   + 1 µF 10 µF   100 µF   10,000 µF   + ip05i.eps   Note correct probe polarity for polarized capacitors.   Download from Www.Somanuals.com. All Manuals Search And Download.   Microamps µA   Range 0 to 200 µA   MULTIMETER   16   µA AC   µA DC   OFF   V •Check   A CAT   TEMPERATURE   600V   COM   + Flame   sensor   probe   Control   module   ip20i.eps   Example: Flame rectification circuit.   Download from Www.Somanuals.com. All Manuals Search And Download.   Diode Test G   Turn off circuit power before testing. For best results diodes   should be measured out of circuit.   Also refer to V•Check.   Good Diode   MULTIMETER   Typical voltage   for silicon diode   MULTIMETER   16   16   Low Impedance   V•Check   OFF   OFF   V •Check   V•Check   A A CAT   CAT   TEMPERATURE   TEMPERATURE   600V   600V   COM   + COM   + Single beep   ip03i.eps   Forward Bias   Reverse Bias   Bad Diode   MULTIMETER   16   MULTIMETER   16   OFF   OFF   V•Check   V•Check   A A CAT   TEMPERATURE   CAT   TEMPERATURE   600V   600V   COM   + COM   + or   ip04i.eps   Shorted   Open   Download from Www.Somanuals.com. All Manuals Search And Download.   µF   MIN MAX   (Records the lowest and highest measurements)   V•Check, autoranging, and Battery Saver are disabled. Put the meter   in the proper range before entering MIN MAX.   When the reading changes more than about 50 digits, the meter gives a   short beep. When a new minimum or maximum is recorded, the meter   gives a long beep.   Enter   MIN MAX   Present Reading with   Input Change AlertTM   Maximum Reading   2 sec   To Exit   Minimum Reading   ip10i.eps   Download from Www.Somanuals.com. All Manuals Search And Download.   µF   MIN MAX with Elapsed Time   Records the hours and minutes between when MIN MAX was entered   and the last high and low was recorded. OL is displayed for times longer   than 99:59.   To enable the MIN MAX timer, hold down M while turning the rotary   switch from OFF to either measurement mode.   Enter MIN MAX. View Maximum Reading   Present Reading   Maximum Reading   Elapsed Time   2 sec   Minimum Reading   Elapsed Time   Minimum Reading   Exit MIN MAX   ip11i.eps   Download from Www.Somanuals.com. All Manuals Search And Download.   Disabling the Beeper   To disable the beeper for all modes, hold down r for 2 seconds while   turning the meter on.   Continuity Capture   To set up the meter to capture intermittent shorts and opens, turn the   switch to GR, connect the leads to the circuit; then press M.   ip12i.eps   Captures transitions longer than 250 µs (1/4000th of a second).   Transitions after the first transition cause the meter to beep, but the   display does not change.   To reset the display to the current condition, press M.   To exit, press M for 2 seconds, or change the measurement mode.   Download from Www.Somanuals.com. All Manuals Search And Download.   Maintenance   Clean the case with a damp cloth and detergent. Do not use abrasives or   solvents.   Battery Replacement   Remove the test leads before disassembling the case.   COM   600V   + + ip13i.eps   Replacement Parts   Fluke TL-75 (Double-insulated leads)   80AK-8001 (Adapter, Thermocouple)   80PK-1 (Probe, Thermocouple, Beaded K-Type)   PN 855705   PN 919683   PN 750422   Service and Parts   This meter should be serviced only by a qualified service technician. For   service information in the USA and Canada call 1-800-526-4731. To   locate an authorized service center, visit us on the World Wide Web:   below.   USA and Canada: 1-800-44-FLUKE (1-800-443-5853)   Europe: +31 402-678-200   Japan: +81-3-3434-0181   Singapore: +65- -276-6196   * Anywhere in the world: +1-425-356-5500   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications   Accuracy is specified for a period of one year after calibration, at 18°C to   28°C (64°F to 82°F) with relative humidity to 90%. AC conversions are   ac-coupled, average responding, and calibrated to the rms value of a sine   wave input. Accuracy specifications are given as follows:   ±([% of reading] + [number of least significant digits])   Function   Range   Resolution   Accuracy   -10°C to 400°C   14°F to 752°F   0.1°C or   0.2°F   ±(1.0% + 0.8°C)   typical   Temperature   ±(1.0% + 1.5°F) typical   ±(5.0% + 1.5°C)   typical   (Type K Thermocouple) -40°C to -10°C   -40°F to 14°F   0.1°C or   0.2°F   ±(5.0% + 3.3°F) typical   Error does not include Type K Thermocouple errors.   Function   Range   Resolution   Accuracy   4000 mV1   4.000V   1 mV   ±(1.9% + 3)   ±(1.9% + 3)   ±(1.9% + 3)   ±(1.9% + 3)   ±(1.9% + 3)   ±(0.9% + 2)   ±(0.9% + 2)   ±(0.9% + 1)   ±(0.9% + 1)   0.001V   00.01V   000.1V   1V   40.00V   400.0V   (50 to 400 Hz)   600V   4000 mV1   4.000V   1 mV   0.001V   00.01V   000.1V   1V   40.00V   400.0V   600V   ±(0.9% + 1)   400.0Ω   0.1Ω   ±(0.9% + 2)   ±(0.9% + 1)   ±(0.9% + 1)   ±(0.9% + 1)   ±(0.9% + 1)   ±(1.5% + 3)   ±(1.9% + 2)   ±(1.9% + 2)   4.000 kΩ   40.00 kΩ   400.0 kΩ   4.000 MΩ   40.00 MΩ   1.000 µF   10.00 µF   100.0 µF   10000 µF   0.001 kΩ   0.01 kΩ   0.1 kΩ   0.001 MΩ   0.01 MΩ   0.001 µF   0.01 µF   0.1 µF   1 µF   Ω ±(1.9% + 2)   ≤1000 µF ±(1.9% + 2)   >1000 µF ±(10% + 90) typical   ±(1.9% + 2)2   2.000V   0.001V   1.The 4000 mV range can be entered only in manual range mode. Use the   4000 mV range with accessories.   2.The beeper is guaranteed to come on at <25Ω and turn off at >250Ω. The   meter detects opens or shorts ≥250 µs.   Download from Www.Somanuals.com. All Manuals Search And Download.   Function   Range Resolution   Accuracy   Burden Voltage   0 to 200 µA   0 to 200 µA   0.1 µA   0.1 µA   ±(2% + 3 counts)   <5 mV/µA   (50 Hz to 400   Hz)   ±(1% + 2 counts)   <5 mV/µA   Overload   Function   Input Impedance (Nominal)   Protection1   >5 MΩ <100 pF   600V rms   V•Check and LoZ = >2 kΩ <200 pF (ac coupled)2   >10MΩ <100 pF   600V rms   V•Check and LoZ = >2 kΩ <200 pF2   Common Mode Rejection   Normal Mode Rejection   Ratio (1 kΩ Unbalanced)   600V rms >60 dB at dc 50 or 60 Hz   600V rms >100 dB at dc, 50 or 60 Hz >50 dB at 50 Hz or 60 Hz   Full Scale Voltage   Open Circuit Test Voltage   To 4.0 MΩ   40 MΩ   600V rms   600V rms   <1.5V dc   <450 mV dc <1.5V dc   2.4-3.0V dc   2.400V dc   Short Circuit Current   600V rms   600V rms   <500 µA   0.95 mA (typical)   1. 3 x 106 V Hz maximum   2. ≅2 kΩ input impedance up to 50V. Impedance increases with input voltage to   >300 kΩ at 600V.   MIN MAX Recording Accuracy and Response Time   Specified accuracy of the measurement function ±12 digits in dc for changes   >200 ms in duration (±40 digits in ac). Typical 100 ms response to 80%.   Example 1: This would mean ±1.2° when recording temperature.   Example 2: This would mean ±12 µA when recording µA or ±12A if used with a   dc amp probe (with a mV input).   Download from Www.Somanuals.com. All Manuals Search And Download.   MIN MAX Recording with Elapsed Time   Elapsed Time   Resolution   Accuracy   0 to 100 hours (99:59)   1 minute   0.3% typical   Maximum Voltage   Between any Terminal   and Earth Ground:   600V rms   Display:   3 3/4-digits, 4000 counts, updates 4/sec   Operating Temperature: -10°C to 50°C (14°F to 122°F)   Storage Temperature:   -30°C to 60°C (-22°F to 140°F)   indefinitely (to -40°C (-40°F) for 100 hrs)   Temperature   Coefficient:   (.1 x specified accuracy)/°C (<18°C or   >28°C)   Relative Humidity:   0% to 90% (-10°C to 35°C; 14°F to 95°F)   0% to 70% (35°C to 50°C; 95°F to 122°F)   9V, NEDA 1604 or IEC 6F22   650 continuous hours with alkaline   450 continuous hours with carbon-zinc   3 meter drops.   Battery Type:   Battery Life:   Shock, Vibration:   Size (H x W x L):   3.46 cm x 7.05 cm x 14.23 cm   (1.35 in x 2.75 in x 5.55 in)   Weight:   Safety:   286g (10 oz)   Designed to Protection Class II   requirement of UL1244, ANSI/ISA-S82,   CSA C22.2 No 231, and VDE 0411, and   IEC 1010 overvoltage Category III (CAT   III, 600 Volts).   EMI Regulations:   Certifications:   Complies with FCC Part 15, Class B, and   VDE 0871B. Trademark of TÜV Product   Services. Complies with EN 61010-1:   1993.   TUV, UL and VDE pending   Download from Www.Somanuals.com. All Manuals Search And Download.   LIMITED WARRANTY & LIMITATION OF LIABILITY   Each Fluke product is warranted to be free from defects in material and workmanship under   normal use and service. The warranty period is three years and begins on the date of shipment.   Parts, product repairs and services are warranted for 90 days. This warranty extends only to the   original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses,   disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered,   neglected or damaged by accident or abnormal conditions of operation or handling. Fluke   warrants that software will operate substantially in accordance with its functional specifications for   90 days and that it has been properly recorded on non-defective media. Fluke does not warrant   that software will be error free or operate without interruption.   Fluke authorized resellers shall extend this warranty on new and unused products to end-user   customers only but have no authority to extend a greater or different warranty on behalf of Fluke.   Warranty support is available if product is purchased through a Fluke authorized sales outlet or   Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for   importation costs of repair/replacement parts when product purchased in one country is submitted   for repair in another country.   Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of   charge repair, or replacement of a defective product which is returned to a Fluke authorized   service center within the warranty period.   To obtain warranty service, contact your nearest Fluke authorized service center or send the   product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to   the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit.   Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB   Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or   abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and   obtain authorization before commencing the work. Following repair, the product will be returned to   the Buyer transportation prepaid and the Buyer will be billed for the repair and return   transportation charges (FOB Shipping Point).   THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL   OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY   IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.   FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR   CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER   ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR   ANY OTHER THEORY.   Since some countries or states do not allow limitation of the term of an implied warranty, or   exclusion or limitation of incidental or consequential damages, the limitations and exclusions of   this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or   unenforceable by a court of competent jurisdiction, such holding will not affect the validity or   enforceability of any other provision.   Fluke Corporation   P.O. Box 9090   Everett WA   Fluke Europe B.V.   P.O. Box 1186   5602 B.D. Eindhoven   The Netherlands   98206-9090   5/94   Download from Www.Somanuals.com. All Manuals Search And Download.   |