Extron electronic Switch FOX T USW 103 User Manual

User Guide  
Fiber Optic Switcher  
FOX T USW 103  
Three Input Universal Switcher  
with an Integrated Fiber Optic Transmitter  
68-2061-01 Rev. A  
07 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Class A Notice  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful  
interference when the equipment is operated in a commercial environment. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  
instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause interference; the user must correct the interference at  
his own expense.  
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility,  
accessibility, and related topics, see the “Extron Safety and Regulatory Compliance  
Guide” on the Extron website.  
FDA/IEC 60825-1 Requirements  
CLASS 1 LASER PRODUCT  
Complies with FDA performance standards for laser products except for deviations pursuant  
to Laser Notice No. 5, dated June 24, 2007.  
The product is intended to be used with the fiber optic cables fully installed.  
This product meets the applicable requirements of IEC 60825-1, Edition 1 (2007).  
Any service to this product must be carried out by Extron Electronics and its qualified  
service personnel.  
Copyright  
© 2013 Extron Electronics. All rights reserved.  
Trademarks  
All trademarks mentioned in this guide are the properties of their respective owners.  
The following registered trademarks(®), registered service marks(SM), and trademarks(TM) are the property of  
RGB Systems, Inc. or Extron Electronics:  
Registered Trademarks(®)  
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, GlobalViewer, Hideaway, Inline, IP Intercom,  
IP Link, Key Minder, LockIt, MediaLink, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, System Integrator,  
TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, XTP Systems  
Registered Service Mark(SM) : S3 Service Support Solutions  
Trademarks()  
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), AIS (Advanced Instruction Set), Auto-Image, CDRS (Class D  
Ripple Suppression), DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator, DSVP  
(Digital Sync Validation Processing), FastBite, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, ProDSP, QS-FPC (QuickSwitch Front Panel  
Controller), Scope-Trigger, SIS, Simple Instruction Set, Skew-Free, SpeedNav, TeamWork, Triple-Action Switching, XTRA, ZipCaddy, ZipClip  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Conventions Used in this Guide  
Notifications  
The following notifications are used in this guide:  
WARNING:  
A warning indicates a situation that has the potential to result in death or  
severe injury.  
CAUTION:  
A caution indicates a situation that may result in minor injury.  
ATTENTION: Attention indicates a situation that may damage or destroy the product or  
associated equipment.  
NOTE: A note draws attention to important information.  
TIP: A tip provides a suggestion to make working with the application easier.  
Software Commands  
Commands are written in the fonts shown here:  
^ARMerge Scene,,Op1 scene 1,1^B51^W^C  
[01]R000400300004000080000600[02]35[17][03]  
EX!*X1&*X2)*X2#*X2!CE}  
NOTE: For commands and examples of computer or device responses mentioned  
in this guide, the character “0” is used for the number zero and “O” represents the  
capital letter “o.”  
Computer responses and directory paths that do not have variables are written in the font  
shown here:  
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32  
C:\Program Files\Extron  
Variables are written in slanted form as shown here:  
ping xxx.xxx.xxx.xxx —t  
SOH R Data STX Command ETB ETX  
Selectable items, such as menu names, menu options, buttons, tabs, and field names are  
written in the font shown here:  
From the Filemenu, select New.  
Click the OKbutton.  
Specifications Availability  
Product specification are available on the Extron website, www.extron.com.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
FOX T USW 103 Universal Switcher • Contents  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FOX T USW 103 Universal Switcher • Contents  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
This section contains general information about this guide and the FOX T USW 103  
Universal Switcher with an integrated fiber optic transmitter, selected device features, and a  
typical application diagram. Topics in this section include:  
About This Guide  
This guide describes installation, operation, and control procedures, and reference  
information for the FOX T USW 103 Universal Switcher with an integrated fiber optic  
transmitter. In this guide, the terms “FOX T USW 103” and “switcher” are used  
interchangeably to refer to the FOX T USW 103 Universal Switcher with an integrated fiber  
optic transmitter in singlemode or multimode.  
About the FOX T USW 103  
The Extron FOX T USW 103 is a three input universal switcher with an integrated fiber optic  
transmitter that provides long haul transmission of HDCP-compliant HDMI, RGBHV, or HD  
component video; stereo audio; and RS-232 signals over fiber optic cabling. The switcher  
delivers pixel-for-pixel transmission of images up to 1920x1200, including HDTV 1080p/60.  
To configure and control the FOX T USW 103, connect a host device, such as a computer,  
and enter Simple Instruction Set (SIS) commands (see Simple Instruction Set Control  
on page 12) or use the FOX Extenders Control Program (see FOX Extenders Control  
Program on page 20).  
System Compatibility  
The FOX T USW 103 operates in either of two modes, selected under RS-232 control, for  
compatibility with other, non-HDMI, units:  
Plus — Supports resolutions up to 1920x1200 @ 60Hz. The fiber optic output of the  
switcher can be received only by one of six receivers: a FOXBOX HDMI Rx,  
FOXBOX DVI Plus Rx, PowerCage HDMI Rx, PowerCage FOX DVI Plus Rx,  
FOXBOX SR HDMI, and PowerCage FOX SR HDMI.  
Non-Plus — Supports resolutions up to 1600x1200 and 1080p @ 60 Hz (including  
HDTV 1080p/60 Hz), is HDCP compliant, and does not contain embedded audio  
(analog audio is still supported). The fiber optic output of the transmitter can be received  
by any FOXBOX, PowerCage FOX, and FOX 500 VGA and DVI unit, including the Plus  
and non-Plus units.  
Cable Transmission Modes  
The transmitter is further categorized by the type of fiber optic cable, multimode  
(FOX T USW 103 MM) or singlemode (FOX T USW 103 SM), which define the effective  
range of transmission:  
Multimode — Long distance, up to 2 km (6,560 feet) (depending on the fiber cable)  
Singlemode — Very long distance, up to 30 km (18.75 miles)  
FOX T USW 103 Universal Switcher • Introduction  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Key Features  
Long distance fiber optics transmission Transmits HDMI or analog video, stereo  
audio, and RS-232 signals up to 30 km when using singlemode fiber optic cabling.  
Inputs — Include two female HDMI type A connectors, one RGBHV/RGBS or HD  
component on 15-pin HD connector, and one unbalanced analog stereo audio on 3.5 mm  
stereo mini-jack.  
All digital technology — Delivers pixel-for-pixel transmission of video signals to ensure  
optimal image quality at resolutions up to 1920x1200, including HDTV 1080p/60.  
Digital conversion of analog video and audio input signals — Digitizes analog signals,  
ensuring that a reliable, high quality digital video signal is sent to the output destination.  
Auto-input switching — Automatically switches to the highest or lowest priority input with  
an active video signal for simplified operation.  
HDCP-compliance  
Key Minder — Authenticates and maintains continuous HDCP encryption between input  
and output devices to ensure quick and reliable switching in professional AV environments,  
while enabling simultaneous distribution of a single source signal to one or more displays.  
EDID Minder — Automatically manages EDID communication between connected devices  
to ensure that all sources properly power up and reliably display content.  
Audio embedding — Converts analog stereo audio signals to digital HDMI audio when the  
analog input is selected.  
Audio gain and attenuation adjustment capability  
LED indicators for signal presence, HDCP, and power — Provides a visual indication of  
system status for real-time feedback and monitoring of key performance parameters.  
RS-232 control — Features an RS-232 serial port for control and configuration.  
Contact closure remote control availability  
Alarm notification for fiber link loss — The FOX T USW 103 can be set up to trigger an  
external control system for immediate notification when a fiber link has been lost. Requires a  
second fiber link.  
Multimode and singlemode availability — Available as an 850 nm multimode model for  
long-range transmissions up to 2 km (6,560 feet), and a 1310 nm singlemode model for  
extreme distances up to 30 km (18.75 miles).  
Industry standard LC fiber optic connectors — Provide reliable physical connectivity  
and precise fiber core alignment.  
Compatibility with the following Extron FOX series products:  
Matrix switchers — Creates HDCP-compliant signal distribution systems up to  
1000x1000 and larger.  
HDMI, DVI Plus, DVI, and VGA receivers — Compatible with FOX series HDMI,  
DVI Plus receivers up to 1920x1200, including HDTV 1080p/60. Compatible with  
FOX series DVI and VGA receivers up to 1600x1200, including HDTV 1080p/60.  
NOTE: The FOX T USW 103 is not compatible with the FOX 3G HD-SDI, FOX 3G DVC,  
or FOX AV models.  
Front panel USB configuration port  
1 inch (2.5 cm) high, half rack width metal enclosure — Compact, low profile enclosure  
for discreet placement and concealment.  
Includes LockIt HDMI cable lacing bracket  
Energy-efficient external universal power supply included — Provides worldwide  
compatibility, low power consumption, and reduced operating costs.  
FOX T USW 103 Universal Switcher • Introduction  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Application Diagram  
The following diagram shows a typical application of the FOX T USW 103 with three input  
sources, a fiber optic receiver, and control system.  
R
VC  
VD  
C
D
DO  
CAM  
LAPTOP  
PC  
Extron  
TouchLink  
Control  
System  
N
O
FF  
O
A
Y
PL  
IS  
MUTE  
FOX T USW 103  
D
SCREPEN  
U
SCREEN  
DOWN  
Fiber Optic Switcher  
TCP/IP  
®
RS-23
REMOTE  
1
00  
K
Y
E
LA  
N
LI  
Extron  
R
T
3
CT  
A
3
INPU  
1
1
ACT  
IR  
G
OM  
3
4
CONT  
C
2
Rx  
R
X
1
0
R
TX  
4
5
2
Tx  
L
2
IP  
1
2
3
M
RS-232  
XPA 1002  
G
FOX  
T
US ALAR  
R
W
10
3
2
RS-232  
1
OVER
2
Power  
Ampli‹er  
1
Rx  
G
LNIK  
Rx  
Tx  
Tx  
RS-232  
LNIK  
INPUTS  
OPTICAL  
3
AUDIO  
HDMI  
2
Up to 30 km  
(18.75 miles)  
singlemode ‹ber  
SM Model  
HDMI  
VGA Laptop  
1
Extron  
A
1002  
XP  
,
B-Y  
R
Y
2
OUTPUT  
1
POWE  
12V  
MA  
X
SI 28  
RGB/R-Y  
CLASS  
REMOmTE  
2
WIRING  
0.7  
A
A
0
5
V
Surface-mount  
Speakers  
0
1
VOL/MUTE  
INPUTS  
2
ANDBY  
T
S
1
HDMI Laptop  
LEVEL  
2
1
2
0
1
0
VGA  
T
z
H
LIMITER/  
0
-6  
0
5
,
PROTEC  
SIGNAL  
A
.3  
1
V
0
4
-2  
0
0
1
Audio  
HDMI  
+ Audio  
HDMI  
+ Audio  
Audio  
Output  
REMOTE  
RS-232  
M
ALA
RS-232  
Tx Rx  
OVER F
2
R
1
AUDIO  
L
OUTPUTS  
Tx Rx  
HDMI  
HDMI AUDIO  
ON  
OFF  
HDMI  
Rx  
FOX SR HDMI  
Blu-ray Player  
Tx  
LNIK  
LNIK  
POWER  
X
OPTICA  
12V  
1.0A MA  
RS-232  
Extron  
FOXBOX SR HDMI  
Fiber Optic Receiver  
Flat Panel Display  
Figure 1. Typical FOX T USW 103 Application  
FOX T USW 103 Universal Switcher • Introduction  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
This section describes information for connecting and wiring the FOX T USW 103. Topics in  
this section include:  
Mounting the FOX T USW 103  
The FOX T USW 103 can be mounted in a rack, under a desk, or on a tabletop (see  
Mounting on page 38 for more mounting details).  
Rear Panel Features  
Tx  
Rx  
FOX T USW 103  
RS-232  
OVER FIBER ALARM  
POWER  
12V  
0.7 A MAX  
REMOTE  
INPUTS  
1
2
3
CONTACT  
RS-232  
AUDIO  
RGB/R-Y, Y, B-Y  
HDMI  
HDMI  
Tx Rx  
G
1
2
1
2
3
G
Tx Rx  
G
OPTICAL  
h
a
b
c
d
e f g  
Figure 2. FOX T USW 103 Rear Panel Features  
Input Connectors  
Analog video connector — Connect a video source to the female 15 HD connector,  
labeled input 1.  
a
b
HDMI connectors — Connect a source device to either or both HDMI connectors,  
labeled inputs 2 and 3 (see Connecting HDMI Connectors on page 6). They can  
accept HDMI, DVI, or dual mode DisplayPort video sources.  
Audio connector — Connect an analog audio source to the 3.5 mm TRS jack. All  
three video inputs can share this audio input.  
c
Tip (L)  
Ring (R)  
Sleeve (  
)
3.5 mm Stereo Plug Connector  
(unbalanced)  
Figure 3.  
Wiring for Unbalanced Stereo Audio  
FOX T USW 103 Universal Switcher • Installation  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
The following table shows the audio format that is sent over the fiber connection when a  
specific audio format is not specified (see the Input audio selection SIS command on  
page 15 to switch the active audio source).  
Selected Video HDMI Embedded  
Analog Audio  
Present  
Audio Sent Over Fiber  
Input  
Audio Present  
VGA  
N/A  
N/A  
Yes  
Yes  
No  
Yes  
No  
Analog audio  
No audio  
VGA  
HDMI  
HDMI  
HDMI  
HDMI  
No  
HDMI embedded audio  
HDMI embedded audio  
Analog audio  
Yes  
Yes  
No  
No  
No audio  
Fiber Optic Connector  
Fiber optic connector — For one-way video, audio, and serial communication from  
the FOX T USW 103 to a receiver, connect a fiber optic cable between the Tx port on  
the FOX T USW 103 and the Rx port on a receiver.  
d
To return serial data from a receiver to the FOX T USW 103 or for HDCP-compliance,  
connect a fiber optic cable between the Rx port on the FOX T USW 103 and the Tx port  
on the receiver (see Wiring for Fiber Communication on page 7).  
NOTES:  
Ensure the proper fiber optic cable is used. Typically, singlemode fiber optic  
cable has a yellow jacket and multimode fiber optic cable has an orange or aqua  
jacket.  
Only one fiber optic cable, transmitter-Tx-to-receiver-Rx, is required for video,  
audio, serial command transmission, but the HDMI signal output on the receiver  
will not be HDCP-compliant and the FOX T USW 103 will not receive RS-232  
reports from the controlled device.  
The Link LED indicators light when there is light presence on either fiber optic port.  
RS-232 Over Fiber and Alarm Connector  
RS-232 Over Fiber port — To pass serial command signals to a receiver  
RS-232  
e
ALARM  
OVER FIBER  
(for serial control of a projector, for example), connect a host device to  
the switcher via the leftmost poles (Tx, Rx, and G) of this 5-pole captive  
Communication on page 8 for wiring configurations).  
Tx Rx G  
1
2
RS-232  
ALARM  
OVER FIBER  
Alarm port For remote monitoring of the status of fiber optic link 2,  
connect a custom or furnished monitoring device to the switcher via the  
rightmost poles (1 and 2) of this 5-pole captive screw connector (see  
Tx Rx G  
1
2
NOTE: Pins 1 and 2 short within the switcher when link 2 does not detect any  
connection.  
FOX T USW 103 Universal Switcher • Installation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Control Connectors  
Contact closure connector — Connect a contact closure device (such as a simple  
f
switch) to the 3.5 mm, 4-pole captive screw connector. The first three ports are used for  
selecting inputs 1 through 3 when momentarily shorted to the ground pin (see Wiring  
RS-232 connector — Connect a host device to the 3.5 mm, 3-pole captive screw  
connector for serial control of the switcher.  
g
Power Connector  
Power connector — Connect an external power supply to the 3.5 mm, 2-pole captive  
screw connector (see Wiring the Power Supply on page 9).  
h
Making Connections  
Connecting HDMI Connectors  
Use an Extron LockIt Lacing Bracket to secure an HDMI cable to each device as follows:  
3
1
4
2
5
Figure 4. Installing the LockIt Lacing Bracket  
1. Plug the HDMI cable into the panel connector.  
2. Loosen the HDMI connection mounting screw from the panel enough to allow the  
LockIt lacing bracket to be placed over it. The screw does not have to be removed.  
3. Place the LockIt lacing bracket on the screw and against the HDMI connector, then  
tighten the screw to secure the bracket.  
ATTENTION: Do not overtighten the HDMI connector mounting screw. The shield  
to which it is fastened to is very thin and can easily be stripped.  
4. Loosely place the included tie wrap around the HDMI connector and the LockIt lacing  
bracket as shown.  
5. While holding the connector securely against the lacing bracket, use pliers or a similar  
tool to tighten the tie wrap, then remove any excess length.  
FOX T USW 103 Universal Switcher • Installation  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Wiring for Fiber Communication  
Rx  
Tx  
WARNING: Risk of serious physical injury. This device outputs  
continuous invisible light, which may be harmful to the eyes; use with  
caution.  
OPTICAL  
Do not look into the rear panel fiber optic cable connectors or into  
the fiber optic cables themselves.  
Plug the attached dust caps into the optical transceivers when the  
fiber cable is unplugged.  
Transmitter  
to  
NOTES:  
Ensure the proper fiber optic cable is used for the  
FOX T USW 103 and receiver. Typically, singlemode fiber optic  
cable has a yellow jacket and multimode fiber optic cable has an  
orange or aqua jacket.  
Receiver  
Rx  
Tx  
Only one fiber optic cable, transmitter-Tx-to-reciever-Rx, is  
required for video, audio, and serial command transmission.  
However, for only one fiber optic cable:  
OPTICAL  
The HDMI signal output by the receiver is not HDCP compliant.  
RS-232 reports from a controlled device are not available.  
To receive responses from the controlled device and for  
HDCP-compliance, install both fiber optic cables.  
FOX T USW 103 Universal Switcher • Installation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Wiring for RS-232 Over Fiber and Alarm Communication  
The RS-232 Over Fiber port is for transmission of serial signals, such as projector control  
signals. The alarm port is an internal relay to connect or disconnect a custom alarm circuit.  
Wire the connector as shown in figure 5 below.  
RS-232  
OVER FIBER ALARM  
Tx Rx  
G
1
2
Tx Rx  
G
1
2
RS-232 Device  
Alarm Device  
Figure 5. Wiring the RS-232 Over Fiber and Alarm Connector  
ATTENTION: The length of exposed wires is critical. The ideal length is  
3/16 inch (5 mm).  
Longer bare wires can short together.  
Shorter wires are not as secure in the connectors and could be pulled out.  
For RS-232 over fiber connection, cross the Tx and Rx lines once between the source and  
the target.  
The alarm pins do not produce any discrete on or off or voltage signals.  
NOTES:  
The alarm port does not produce any discrete on or off voltage signals.  
If power is lost or if link 2 optical light is disconnected, lost, or broken, alarm pins 1  
and 2 internally short.  
Wiring for Remote Contact Closure Communication  
Each port senses an external switch or contact closure. Use these ports to select an input  
on the switcher. Wire the connector as shown in figure 6 below.  
CONTACT  
1
2
3
G
Heat  
Shrink  
Over  
Shield  
Wires  
Ground  
Wire Nut  
Device 3  
(Switches,  
relays, or  
similar items)  
G
3
2
1
Switch  
Device 2  
Device 1  
Figure 6. Wiring the Contact Closure Connector  
FOX T USW 103 Universal Switcher • Installation  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Wiring the Power Supply  
Connect a 12 VDC power supply to the 3.5 mm, 2-pole captive screw connector.  
2-Pole Captive Screw  
Connector  
Tie Wrap  
Smooth  
SECTION A–A  
3/16”  
(5 mm) Max.  
Ridges  
A
A
Power Supply  
Output Cord  
Figure 7. Power Connector Wiring  
CAUTION: Electric shock hazard. The two power cord wires must be kept separate  
while the power supply is plugged in. Remove power before wiring.  
ATTENTION:  
This product is intended to be supplied by a Listed Power Unit marked “Class 2”  
or “LPS,” rated 12 VDC, 1.0 A minimum. Always use a power supply supplied by  
or specified by Extron. Use of an unauthorized power supply voids all regulatory  
compliance certification and may cause damage to the supply and the end product.  
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling  
spaces or in wall cavities. The installation must always be in accordance with the  
applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and  
the Canadian Electrical Code part 1, section 16. The power supply shall not be  
permanently fixed to a building structure or similar structure.  
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the  
power supply and the unit. The ridges on the side of the cord identify the power cord  
negative lead.  
The length of the exposed (stripped) copper wires is important. The ideal length is  
3/16 inch (5 mm).  
TIP: Do not tin the stripped power supply leads. Tinned wires are not as secure in the  
captive screw connectors and could be pulled out.  
FOX T USW 103 Universal Switcher • Installation  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation  
This section describes the front panel features of the FOX T USW 103 and describes front  
panel operations. Topics in this section include:  
Front Panel Features  
STATUS  
2
AUTO  
SWITCH  
1
2
3
1
3
SIGNAL  
HDCP  
CONFIG  
MODE  
NORMAL  
AUTO  
FOX T USW 103  
a
b
c
d
Figure 8. FOX T USW 103 Front Panel Features  
Auto Switch LED — Lights when the transmitter is in auto switch mode.  
a
b
c
Config port — Connect a host device to the mini USB Config port for remote control.  
Input selection buttons — Select inputs 1 through 3 or modes of operation. The  
corresponding LEDs light to indicate the active input.  
Status LEDs — The Signal LEDs light to indicate the signal presence of each input.  
The HDCP LEDs light when the signal on the corresponding input is HDCP compliant.  
Input 1 (the VGA connector) does not have an HDCP LED.  
d
Front Panel Operation  
The three buttons with corresponding LEDs on the front panel (labeled Mode, Normal, and  
Auto) are used to manually select inputs 1 through 3 or enable and disable device modes.  
The LEDs indicate status and the currently selected input.  
To enable or disable executive, auto switch, or normal switch mode from the front panel,  
press and hold a combination of input selection buttons simultaneously until the appropriate  
LEDs blink (see the table below for the different button combinations).  
Front Panel Button Combinations for Device Modes  
Mode  
Button Combinations  
Executive  
1, 2, and 3  
Auto switch  
(prioritize the highest numbered active input)  
1 and 3  
1 and 2  
Normal switch (default)  
The front panel operations can also be performed remotely with SIS commands or the FOX  
Extenders Control Program (see Simple Instruction Set Control on page 12 or  
FOX T USW 103 Universal Switcher • Operation  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Initial Power Up  
Upon initial power up, the front panel LEDs blink simultaneously. They blink once for  
multimode or twice for singlemode. Afterwards, the LEDs return to their normal signal  
presence indication.  
If a different fiber optic SFP module or no SFP module is connected, the LEDs first blink  
once or twice to identify the device, but then blink continuously.  
Selecting an Input  
To select an input from the front panel, perform the following actions:  
1. Press the input selection button that corresponds with the desired rear panel input  
connector.  
2. The corresponding LED lights to indicate the active input.  
Enabling or Disabling Front Panel Lockout Mode (Executive Mode)  
Push and hold (for about 5 seconds) inputs 1, 2, and 3 simultaneously until the front  
panel LEDs blink three times to enable or disable front panel configuration. In executive  
mode, contact closure and RS-232 control are still available. By default, executive mode is  
disabled.  
Enabling Auto Switch Mode  
Press and hold (for about 3 seconds) inputs 1 and 3 simultaneously until the front panel  
Auto Switch LED lights. This prioritizes the highest numbered active input.  
NOTE: Setting audio switch mode to prioritize the lowest numbered active input can be  
done only with SIS commands (see Auto switch mode SIS commands on page 15).  
Normal switch mode is the default mode.  
Enabling Normal Switch Mode  
Press and hold (for about 3 seconds) inputs 1 and 2 simultaneously until the front panel  
Auto Switch LED turns off. This is the default mode.  
FOX T USW 103 Universal Switcher • Operation  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SIS Configuration  
and Control  
This section describes remote control of the FOX T USW 103 through SIS commands  
and basic installation instructions for the FOX Extenders Control Program (see to the FOX  
Extenders Control Program Help File for operation details).  
To enable serial control of the FOX T USW 103, use a computer running the HyperTerminal  
or Extron DataViewer utility, or a control system. Connect the computer to the  
FOX T USW 103 through the front panel Config port or the rear panel RS-232 connector.  
The protocol for the RS-232 port is as follows: 9600 baud, no parity, 8 data bits, 1 stop bit,  
no flow control  
Simple Instruction Set Control  
SIS Programming Guide  
Host-to-device and device-to-host communication  
SIS commands consist of one or more characters per field. No special characters are  
required to begin or end a command sequence. When the FOX T USW 103 determines that  
a command is valid, it executes the command and sends a response to the host device.  
All responses from the switcher or receiver to the host end with a carriage return and a line  
feed (CR/LF = ]), which signals the end of the response character string. A string is one or  
more characters.  
Device-initiated messages  
When a local event occurs, the device responds by sending a message to the host. The  
device-initiated message may depend on whether the device is multimode or singlemode.  
They are listed below.  
© Copyright 2013, Extron Electronics FOX T USW 103 MM, Vx.xx, 60-1229-11  
© Copyright 2013, Extron Electronics FOX T USW 103 SM, Vx.xx, 60-1229-12  
Vx.xx is the firmware version number.  
Reconfig]  
The FOX T USW 103 returns this message when there is any change to the input frequency  
on the currently selected input.  
1LnkX%2LnkX%VidX%AudX%X1)TX]  
The FOX T USW 103 returns this status message whenever a change in the fiber link, video,  
or audio connection occurs. X%indicates whether the link is present or not present  
(0= not present, 1= present) and X1)represents whether the device is multimode or  
singlemode (MM= multimode, SM= singlemode).  
FOX T USW 103 Universal Switcher • Remote Control  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Error responses  
When the FOX T USW 103 receives an SIS command and determines that it is valid, it  
performs the command and sends the corresponding response to the host device. If the  
command is determined invalid or contains invalid parameters, the switcher or receiver  
returns an error response to the host. The error response codes are:  
E01= Invalid input number  
E13= Invalid parameter  
E06= Invalid switch attempt in this mode E14= Not valid for this configuration  
E10= Invalid command  
E12= Invalid port number  
E17= Invalid command for signal type  
E22= Busy  
Using the command and response table for SIS commands  
The Command and Response Tables begin on page 15. Lowercase letters are  
acceptable in the command field except where indicated. Figure 9 shows the hexadecimal  
equivalent of ASCII characters used in the command and response tables.  
ASCII to Hex Conversion Table  
Space  
Figure 9. ASCII to Hexadecimal Conversion  
Symbol definitions  
=
=
=
=
Carriage return and line feed  
Carriage return with no line feed  
Space  
]
¦ or }  
Escape key  
Eor W  
FOX T USW 103 Universal Switcher • Remote Control  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
=
EDID output resolution and refresh  
rate  
See the tables below.  
X2^  
VGA - PC  
SIS  
Resolution  
Refresh  
SIS  
Resolution Refresh  
SIS  
Resolution  
Refresh  
Value  
Rate (Hz) Value  
Rate (Hz) Value  
Rate (Hz)  
1
2
800x600  
60  
60  
7
8
1360x768  
1366x768  
60  
60  
12  
13  
1600x1200  
1680x1050  
60  
60  
1024x768  
1280x720  
(analog default)  
3
60  
9
1400x1050  
60  
14  
1920x1080  
60  
4
5
6
1280x768  
1280x800  
1280x1024  
60  
60  
60  
10  
11  
1440x900  
1600x900  
60  
60  
15  
16  
1920x1200  
2048x1080  
60  
60  
DVI - PC  
SIS  
Resolution  
Refresh  
SIS  
Resolution Refresh  
SIS  
Resolution  
Refresh  
Value  
Rate (Hz) Value  
Rate (Hz) Value  
Rate (Hz)  
17  
18  
19  
20  
21  
22  
800x600  
1024x768  
1280x720  
1280x768  
1280x800  
1280x1024  
60  
60  
60  
60  
60  
60  
23  
24  
25  
26  
27  
1360x768  
1366x768  
1400x1050  
1440x900  
1600x900  
60  
60  
60  
60  
60  
28  
29  
30  
31  
32  
1600x1200  
1680x1050  
1920x1080  
1920x1200  
2048x1080  
60  
60  
60  
60  
60  
HDMI - PC with 2-channel Audio  
SIS  
Resolution  
Refresh  
SIS  
Resolution  
Refresh  
SIS  
Resolution  
Refresh  
Value  
Rate (Hz) Value  
Rate (Hz) Value  
Rate (Hz)  
33  
34  
35  
36  
37  
800x600  
1024x768  
1280x768  
1280x800  
1280x1024  
60  
60  
60  
60  
60  
38  
39  
40  
41  
42  
1360x768  
1366x768  
1400x1050  
1440x900  
1600x900  
60  
60  
60  
60  
60  
43  
44  
45  
46  
1600x1200  
1680x1050  
1920x1200  
2048x1080  
60  
60  
60  
60  
HDMI HDTV  
Resolution  
SIS  
Resolution  
Refresh  
SIS  
Refresh  
SIS  
Resolution  
Refresh  
Value  
Rate (Hz) Value  
Rate (Hz) Value  
Rate (Hz)  
480p  
2-ch audio  
1080i  
2-ch audio  
User assigned  
or imported 1  
47  
48  
49  
60  
50  
50  
51  
52  
53  
50  
60  
50  
55  
56  
57  
576p  
2-ch audio  
1080i  
2-ch audio  
User assigned  
or imported 2  
720p  
2-ch audio  
1080p  
2-ch audio  
User assigned  
or imported 3  
720p  
2-ch audio  
(digital default)  
1080p  
2-ch audio  
50  
60  
54  
60  
FOX T USW 103 Universal Switcher • Remote Control  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command and Response Tables for SIS Commands  
Command  
ASCII Command  
(Host to Device)  
Response  
(Device to Host)  
Additional Description  
Input Switching  
Input selection  
NOTE: The FOX T USW 103 saves the last input selection when cycling power.  
Set video input selection  
View video input selection  
X1!!  
!
InX1! All]  
Select input X1!.  
View currently selected  
source.  
X1!]  
Auto switch mode  
Disable auto switch mode  
Switch inputs manually  
(default).  
E0AUSW}  
E1AUSW}  
E2AUSW}  
EAUSW}  
Ausw0]  
Ausw1]  
Ausw2]  
X1@]  
Set priority to the highest  
active input  
Gives priority to the highest  
numbered active input.  
Set priority to the lowest  
active input  
Gives priority to the lowest  
numbered active input.  
View the auto switch mode  
View the auto switch mode.  
Audio Configuration  
Audio gain and attenuation  
NOTE: Gain and attenuation are case-sensitive.  
Set gain  
X&G  
AudX(]  
AudX(]  
AudX(]  
Set gain to X(.  
Set attenuation  
Increment audio level  
X*g  
+Gor +g  
Set attenuation to X(.  
Increase the gain or  
attenuation.  
Decrement audio level  
-Gor -g  
Gor g  
Decrease the gain or  
attenuation.  
AudX(]  
View audio level  
View the audio level.  
X(]  
Input audio selection  
Set audio input format  
EIX1!*X2%AFMT}  
EIX1!AFMT}  
AfmtIX1!*X2%]  
Set input X1!to X2%audio  
format.  
View audio input format  
View the audio iput format.  
X2%]  
NOTE: X&= Audio gain  
0to 10(0= default)  
18to 0  
X*= Audio attenuation  
X(= Audio level  
18to 10  
X1!= Input selection  
1= VGA (input 1)  
2= HDMI (input 2)  
3= HDMI (input 3)  
X1@= Auto switch mode  
X2%= Audio input format  
0= manual switching (default)  
1= priority given to the highest numbered active input  
2= priority given to the lowest numbered active input  
0= auto (default)  
1= digital embedded  
2= analog  
FOX T USW 103 Universal Switcher • Remote Control  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Command  
ASCII Command  
(Host to Device)  
Response  
(Device to Host)  
Additional Description  
Picture Adjustment (Analog Only)  
Pixel phase  
Set a pixel phase value  
Increment value  
E1*X2@PHAS}  
E1+PHAS}  
E1-PHAS}  
E1PHAS}  
PhasX2@]  
PhasX2@]  
PhasX2@]  
X2@]  
Adjust the pixel phase to X2@.  
Increase the pixel phase.  
Decrement value  
Decrease the pixel phase  
Show the pixel phase value  
View pixel phase value  
Total pixels  
Set a value  
Set the total pixels.  
E1*X2#TPIX}  
E1+TPIX}  
E1-TPIX}  
E1TPIX}  
TpixX2#]  
TpixX2#]  
TpixX2#]  
X2#]  
Increment value  
Decrement value  
View total pixel value  
Increase the total pixels.  
Decrease the total pixels.  
Show the total pixels.  
Horizontal start  
Set horizontal start value  
Set horizontal location of first  
active pixel in active window.  
E1*X2$HSRT}  
HsrtX2$]  
Increment value  
Move the image to the right.  
Move the image to the left.  
E1+HSRT}  
E1-HSRT}  
E1HSRT}  
HsrtX2$]  
HsrtX2$]  
X2$]  
Decrement value  
View horizontal start value  
Show horizontal location of the  
first active pixel in active window.  
EDID  
NOTE: Digital EDID can be assigned only to a digital input. Analog EDID can be assigned only to an analog  
input.  
Input EDID (VGA and HDMI)  
Assign factory EDID  
Set the EDID resolution and  
refresh for input X1!.  
EAX1!*X2^EDID} EdidAX1!*X2^]  
View assigned EDID  
View EDID resolution and refresh  
for input X1!.  
EAX1!EDID}  
X2^]  
View EDID native resolution  
View current EDID in Hex  
Export EDID selection  
ENX1!EDID}  
ERX1!EDID}  
EEX2^EDID}  
EIX1$EDID}X$  
X@]  
X#]  
Export EDID in binary format.  
X$]  
Import EDID to store  
location  
Import EDID in binary format to  
EdidIX1$]  
user stored EDID slot X1$.  
NOTE: X@= Native resolution and refresh rate  
X#= EDID record (Hex)  
128 or 256 bytes  
128 or 256 bytes  
X$= EDID record (binary)  
X1!= Input selection  
1= VGA (input 1)  
2= HDMI (input 2)  
3= HDMI (input 3)  
X1$= User assigned EDID  
55= VGA (input 1)  
56= HDMI (input 2)  
57= HDMI (input 3)  
X2@= Pixel phase  
0to 63(32= default)  
X2#= Total pixels  
X2$= Horizontal start  
X2^= EDID output resolution  
255of the default value (depends on the input rate)  
0to 255(128= default)  
See the tables on page 13.  
FOX T USW 103 Universal Switcher • Remote Control  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command  
ASCII Command  
(Host to Device)  
Response  
(Device to Host)  
Additional Description  
Advanced Configurations  
Input sync detection  
View input sync detection  
Shows horizontal frequency in  
kHz and vertical frequency in  
Hz. Returns 000.0,000.0if no  
signal is detected.  
E1LS}  
xxx.x,xxx.x]  
Input video format (VGA only)  
Set input video format  
1*X1%\  
Typ1*X1%]  
Sets input 1 to format X1%.  
1\  
View input video format  
View video format of input 1.  
X1%]  
Front panel lockout  
Set front panel executive  
mode  
Enable or disable (default) the  
front panel lockout (executive)  
mode.  
X%X  
ExeX%]  
X
View front panel executive  
mode  
View the front panel lockout  
(executive) mode.  
X%]  
Plus mode transmission  
81*0#  
81*1#  
81#  
Disable Plus mode  
transmission  
Disable Plus mode  
transmission.  
Plus0]  
Plus1]  
X%]  
Enable Plus mode  
transmission  
Enable Plus mode transmission  
(default).  
View Plus mode transmission  
View Plus mode transmission  
setting.  
HDCP authorized device (HDMI inputs only)  
HDCP authorized device On  
HDCP authorized device on for  
input X1!(default).  
HDCP authorization off for input  
X1!.  
View the HDCP authorization  
status.  
EEX1!*1HDCP}  
EEX1!*0HDCP}  
EEX1!HDCP}  
HdcpEX1!*1]  
HdcpEX1!*0]  
X^]  
HDCP authorized device Off  
Query HDCP authorized  
device status  
HDCP status (HDMI inputs only)  
Query HDCP status  
View the HDCP status.  
EIX1!HDCP}  
X1#]  
NOTE: X%= Enable or disable  
X^= HDCP authorization  
X1!= Input selection  
0= off or not detected  
1= on or detected  
0= HDCP authorization off  
1= HDCP authorization on (default)  
1= VGA (input 1)  
2= HDMI (input 2)  
3= HDMI (input 3)  
X1#= HDCP status (HDMI only)  
X1%= Input video format  
0= no source device detected  
1= source detected with HDCP  
2= source detected but no HDCP is present  
0= auto detect (default)  
1= RGB  
2= YUV  
FOX T USW 103 Universal Switcher • Remote Control  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command  
ASCII Command Response  
Additional Description  
(Host to Device)  
(Device to Host)  
Device name  
NOTE: No blank or space characters are permitted. The first character must be a letter. The last character  
cannot be a minus or hyphen.  
Set unit name  
Set device name.  
EX1^CN}  
Ipn X1^]  
Set unit name to factory  
default  
Set device to default.  
E CN}  
Ipn X1&]  
View unit name  
View device name.  
ECN}  
X1^]  
Information requests  
Query general information  
Query firmware version  
Query firmware build  
I
1LnkX% 2LnkX% VidX% AudX% X1) TX]  
Q
x.xx]  
*Q  
N
x.xx.xxxx]  
60-1229-nn]  
x.xx-x.xx]  
x.xx]  
Query part number  
0Q  
35Q  
Query all firmware version  
Query updated FPGA version  
Status request  
1S  
2S  
3S  
4S  
5S  
6S  
7S  
View fiber link 1 status  
View fiber link 2 status  
View input video status  
View input audio status  
Request all signal status  
Request HDMI signal status  
Request HDCP status  
X%]  
X%]  
X%X%X%]  
X%]  
SigIX%X%X% SigO- 2HdcpIX% 3HdcpIX% HdcpO-]  
SigIX%X% SigO-]  
2HdcpIX% 3HdcpIX% HdcpO-]  
NOTE: X%= On or off  
X1)= SFP module type  
X1!= Input selection  
0= off or not detected  
1= on or detected  
SM= singlemode  
MM= multimode  
1= VGA (input 1)  
2= HDMI (input 2)  
3= HDMI (input 3)  
X1^= Unit name  
text string up to 24 characters (A-Z, 0-9, -). No blank  
or space characters are permitted. The first character  
must be a letter. The last character cannot be a hyphen.  
X1&= Extron device name  
FOX-T-USW-103  
FOX T USW 103 Universal Switcher • Remote Control  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command  
ASCII Command Response  
Additional Description  
(Host to Device)  
(Device to Host)  
View internal temperature  
20S  
View internal temperature  
Internal temperature in  
degrees Fahrenheit and  
Celsius.  
X!]  
Factory reset  
System Reset (factory default)  
Resets unit to factory default.  
EZXXX}  
EZA}  
Zpx]  
Zpa]  
Reset audio gain and  
attenuation  
Reset audio gain and  
attenuation to default levels.  
Upload firmware  
Upload firmware  
EUpload}  
Sendheader]  
SFP module  
40S  
View SFP module information  
X1* X1( X2) X2!]  
NOTE: X!= Internal temperature  
in degrees Fahrenheit and Celsius  
X1*= Vendor or manufacturer name  
X1(= Transmit (Tx) output power  
X2)= Receive (Rx) optical power  
X2!- Operation temperature  
in dBm  
in dBm  
in ˚C  
FOX T USW 103 Universal Switcher • Remote Control  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FOX Extenders  
Control Program  
The Extron FOX Extenders Control Program provides an alternate method to control  
and configure the FOX T USW 103. The application provides controls to adjust device  
parameters that are specific to the basic and advanced setup of the transmitter. Users can  
also manage firmware and check for updates to the application. The Extron FOX Extenders  
Control Program communicates with the transmitter via the Remote RS-232 port on the rear  
panel Remote RS-232 and Alarm connector or front panel USB Config port. The program  
is compatible with Microsoft® Windows® 2000, Windows XP, or later Windows operating  
systems. Updates to this program can be downloaded from the Extron website  
(www.extron.com). Topics in this section include:  
Installing the Software  
The program is contained on the Extron Software Products DVD or available for download  
on the Extron website, www.extron.com.  
To install the software from the DVD:  
1. To install the software, insert the DVD into the DVD drive. The Extron software DVD  
window should appear automatically. If it does not self-start, run Launch.exe from the  
DVD.  
2. Click the Softwaretab, scroll to the desired program, and click Install.  
3. Follow the instructions that appear on the screen. By default, the installation creates a  
folder in the Program Files directory for the FOX Extenders Control Program.  
To download the software from the website:  
1. On the Extron website, click the Downloadtab.  
2. From the left sidebar, click the Softwarelink.  
3. Navigate to FOX Extenders.  
4. Click the Downloadlink to the right of the desired device.  
5. Submit any required information to start the download. Note where the file is saved.  
6. Open the executable (.exe) file from the save location.  
7. Follow the instructions that appear on the screen. By default, the installation creates a  
folder in the Program Files directory for the FOX Extenders Control Program.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Starting the Software  
Start the Extron FOX Extenders Control Program as follows:  
1. Open the FOX Extenders Control Program. The Communication Setup window  
appears.  
Figure 10. Communication Setup Window Connection Methods  
2. Select the desired connection method.  
To connect the software to the device through the rear panel Remote RS-232  
connector, click the RS232tab and select the desired port from the Port  
drop-down list.  
To connect the software to the device through the front panel USB connector, click  
the USBtab and select the Extron USB device from the Extron USB Devicedrop-  
down list.  
3. Click the Connectbutton. The FOX Extenders Control Program window appears.  
NOTE: Some controls and displays are available only when connected to specific  
devices.  
Using the Software  
For more configuration and control details, see to the FOX Extenders Control Program Help  
File for configuration and control details. Open the file using one of the following methods:  
Once the FOX Extenders Control Program is open, press the <F1> key on the  
keyboard.  
Once the FOX Extenders Control Program is open, select Contentsfrom the Help  
menu.  
From the Windows Start Menu, select FOX Extenders Helpfrom the FOX Extenders  
Control Program folder.  
The main screen opens (see figure 12 on page 23).  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Figure 11. Main Screen  
The main screen consists of a top menu, Status panel, Input Selection panel, and  
Configuration panel.  
Top Menu  
The top menu consists of three menus for connection options, device information and  
configuration, and additional resources.  
File menu  
The File menu contains options for connecting and disconnecting the device and exiting the  
FOX Extenders Control Program.  
Figure 12. File Menu  
Options that appear gray are not available.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connect  
The Connect option establishes communication with a device. This function re-establishes  
communication with the device if it times out or enables a connection to a new device.  
If a device is already connected, the Connect function is disabled until the device is  
disconnected or the connection times out.  
To re-establish the connection if communication is lost:  
1. From the Filemenu, select Connect. Alternatively, click the  
icon. This displays the  
Communication Setup dialog box, which is the communication module through which  
connection to the device is established.  
2. Select the communication port from the Portdrop-down list.  
3. Click Connect. The Communication Setup dialog box closes and the FOX Extenders  
Control Program main screen remains open.  
Disconnect  
The Disconnect option stops communication with the current device, but leaves the FOX  
Extenders Control Program open. Once disconnected, configuration can no longer be done  
unless connection is re-established.  
To disconnect from the device, select Disconnectfrom the Filemenu or click the  
icon.  
The status bar at the bottom of the window indicates that the device is disconnected.  
Exit  
The Exit option closes the FOX Extenders Control Program.  
To exit the program, select Exitfrom the Filemenu.  
Tools Menu  
The Tools menu contains options for displaying device information or configuring the device.  
Figure 13. Tools Menu  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unit Info  
The Unit Info option opens a dialog box with information about the connected device.  
Figure 14. Unit Info Dialog Box  
1. From the Toolsmenu, select Unit Info. This opens a dialog box displaying  
information about the connected unit. The displayed information includes:  
Model number of the device  
Name of the device model  
Description of the model  
Firmware version currently found on the device  
Firmware build  
FPGA version  
2. Click the OKbutton to close the dialog box and return to the main screen.  
Reset Unit  
There are three listed reset options:  
Master System Reset  
Audio Gain/Atten. Reset  
Presets Reset  
Depending on the chosen reset option, different settings are cleared.  
Figure 15. Reset Unit Menu  
NOTE: Be careful to select the intended reset option. Selecting the incorrect reset can  
result in unintended loss of settings.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Master System Reset — Resets all unit settings and user settings to factory defaults.  
From the Toolsmenu, locate the Reset submenu and select Master System Reset.  
Figure 16. Unit System Dialog Box  
Audio Gain/Atten. Reset — Resets the level of audio gain and attenuation to factory  
defaults.  
From the Toolsmenu, locate the Reset submenu and select Audio Gain/Atten. Reset.  
Figure 17. Audio Gain and Attenuation Reset Dialog Box  
Presets Reset — Is not available for the FOX T USW 103.  
Update Firmware  
The Update Firmware option opens the Extron Firmware Loader application. This application  
is used to upload new firmware to the connected device.  
NOTE: In order for the Update Firmware option to work, install the Firmware Loader  
application (see Downloading Extron Firmware Loader on page 38). Otherwise, the  
Update Firmware option is disabled.  
To update firmware:  
1. From the Toolsmenu, select Update Firmware. Alternatively, click the  
icon. This  
opens Firmware Loader (if this application is already installed on the connected PC).  
2. Find firmware to upload to the desired device by performing one of the following  
actions:  
From the Filemenu of Firmware Loader, select New Firmware for Selected  
Devices.  
In the Devices section of the Firmware Loader main screen, double-click the New  
Firmware Filefield associated with the selected device.  
The Choose Firmware File dialog box opens.  
3. Browse to the device-specific firmware file that has been downloaded on your PC. Valid  
firmware files have a BIN file extension (see Downloading Firmware on page 40).  
4. Click the Openbutton. The Choose Firmware File dialog box closes.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Click the Beginbutton. This uploads the new firmware onto the connected device.  
The Progressfield for the selected device shows the progress of the upload. After the  
upload is complete, this field is blue and shows 100%.  
6. Exit Firmware Loader.  
7. From the Filemenu of the FOX Extenders Control Program, select Connectto  
re-establish communication with the device.  
8. Re-enter the connection information in the Connect dialog box to re-establish  
communication with the device.  
See the Firmware Loader Help File and supporting documentation for further information  
about using Firmware Loader.  
Refresh  
The Refresh option refreshes the main screen of the FOX Extenders Control Program  
without restarting the application. This is useful if connection to a device is lost (such as if  
the unit has been unplugged accidentally) or settings change on the device.  
From the Toolsmenu, select Refresh. Alternatively, click the  
icon.  
Trace Window  
The Trace Window option displays data sent to and received from the device in a separate  
window for troubleshooting.  
Figure 18. Trace Window Dialog Box  
1. From the Toolsmenu, select Trace Window. The Trace Window dialog box opens.  
2. To clear existing information, click the Clearbutton.  
3. Click the Closebutton to close the Trace Window dialog box.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Help Menu  
The Help menu contains options for additional information and reference material, checking  
for updates to the FOX Extenders Control Program, and software information.  
Figure 19. Help Menu  
Contents  
The Contents option launches the FOX Extenders Control Program help file.  
Open the help file in one of the following ways:  
From the Helpmenu, select Contents.  
Press <F1> on your keyboard.  
Click the  
icon to launch the help file.  
Extron Home Page  
The Extron Home Page option displays the Extron website. The Extron website contains  
supporting documentation for Extron products and downloadable firmware and software  
updates (see Download Extron Firmware Loader on page 38).  
From the Helpmenu, select Extron Home Page. This opens a new Internet browser  
window to the Extron website.  
Check for Updates  
The Check for Updates option verifies that the latest version of the FOX Extenders Control  
Program is being used. If there is a new version available, the option to install it becomes  
available.  
From the Helpmenu, select Check for Updates.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About...  
This option opens a dialog box displaying information about the FOX Extenders Control  
Program.  
1. From the Helpmenu, select About. This opens a dialog box displaying information  
about the FOX Extenders Control Program. The displayed information includes:  
Name of the application  
Currently installed software version  
Software part number  
Copyright  
Application description  
Figure 20. About FOX Extenders Control Program Dialog Box  
2. Click the OKbutton to close this dialog box and return to the main screen of the  
application.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main Screen  
The Main Screen contains status information, input selection, and configuration options.  
Figure 21. Main Screen  
NOTE: The main screen may appear different from the image above depending on what  
is connected. Functions which are not applicable are disabled.  
Status panel  
Figure 22. Status Panel  
The Status panel of the screen provides visual indications of the connection status and the  
names of the connected units. The following information is displayed:  
Link 1 Indicator — Displays green when the receiver detects light on Link 1 (connecting  
the Tx port of the transmitter to the Rx port of the receiver).  
Link 2 Indicator — Displays green when an HDMI transmitter detects light on Link 2  
(connecting the Tx port of an HDMI receiver to the Rx port of an HDMI transmitter).  
NOTE: For transmission of HDMI video with HDCP content, two fibers are required.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Video Indicator — Displays green when the transmitter detects an active signal on the VGA  
input.  
Audio Indicator — Displays green when the device detects audio with the selected input.  
If the selected input has an analog audio signal above -44 dBV, the indicator turns green  
immediately, but turns gray after the audio signal level drops below the threshold continuously  
for 10 seconds. If the selected input has digital embedded audio, the indicator displays green  
and remains green as long as the digital audio signal is detected.  
HDMI Indicator — Displays green when the unit receives an HDMI input signal.  
HDCP Indicator — Displays green if the input signal is HDCP-encrypted.  
EDID Minder — Displays the current EDID Minder settings.  
Input Frequency — Displays the horizontal and vertical frequencies of the current input. This  
field indicates No Input Signal if there is no input signal.  
Model — Displays the model of the device that is connected via RS-232 or USB.  
Connected to — Displays the communication port of the unit that is connected to the PC.  
This can be either a communication port on the transmitter or a communication port on the  
receiver.  
Other side — Displays N/Awhenever connected to a FOX T USW 103.  
Temperature — Displays the internal temperature of the device.  
Input Selection panel  
The Input Selection panel is used to select inputs manually or automatically.  
Figure 23. Input Selection Panel  
Select Input — Select the desired input. The currently selected input is green. The left button  
represents Input 1 (VGA). The right button represents Input 2 (HDMI).  
Auto Switch Mode — Allows the device to auto switch inputs based on the chosen  
configuration. The options are Disabled, Priority to Highest Active, or Priority to Lowest Active.  
NOTE: The Default setting on the FOX T USW 103 is Disabled.  
Control tab  
The Control tab contains picture and audio adjustments. To access these options, click the  
Controltab.  
Figure 24. Control Tab  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VGA Video Adjustment panel  
The VGA Video Adjustment panel of the Control tab adjusts the following video parameters  
on the analog input: horizontal start, pixel phase, and total pixels.  
Figure 25. VGA Video Adjustment Panel  
Horizontal Start — Defines the number of pixels in the blanking area to the left of the  
active area.  
In the Horizontal Start panel of the VGA Video Adjustment panel, click the Leftor Right  
arrows, or click and drag the slider to adjust the setting to the desired value. The field to the  
right of a slider shows the current value for the associated setting.  
NOTE: The value for Horizontal Start can range between 0 and 255.  
Default setting: 128.  
Pixel Phase — Controls the pixel phase. Sampling at the optimum pixel phase results in a  
bright, stable output.  
In the Pixel Phase panel of the VGA Video Adjustment panel, click the Leftor Right  
arrows, or click and drag the slider to adjust the setting to the desired value. The field to the  
right of a slider shows the current value for the associated setting.  
NOTE: The value for Pixel Phase can range between 0 and 63. Default setting: 32.  
The Total Pixels setting (see below) must be correctly set before adjusting Pixel Phase.  
Total Pixels — Controls the total number of pixels in an active window.  
In the Shift panel of the VGA Video Adjustment panel, click the Leftor Rightarrows, or  
click and drag the slider to adjust the setting to the desired value. The field to the right of a  
slider shows the current value for the associated setting.  
NOTE: The Total Pixels setting depends on the input rate. It is 255 of the default value.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Audio Adjustment panel  
The Audio Adjustment panel of the Control tab allows adjusts the gain and attenuation of  
analog input audio.  
Audio Gain and Attenuation — Adjusts the analog input audio gain or attenuation value.  
This ranges from -18.0 dB to +10.0 dB in 1.0 dB increments.  
In the Audio Gain/Atten. panel, click and drag the slider to the desired level. The current  
value is displayed in a field below the slider control.  
Audio Output Level — Is not available for the FOX T USW 103.  
I/O Configuration Tab  
The I/O Configuration tab contains options for input and output settings. To access these  
options, click the I/O Configurationtab.  
Figure 26. I/O Configuration Tab  
HDCP panel  
The HDCP Authorized setting allows a user to turn off HDCP communication on discrete  
inputs. This setting is useful for devices such as Mac computers, iPhones, iPads, and some  
Windows 7 sources that will always encrypt their output if the downstream sink is capable  
of HDCP. By not allowing HDCP signals on an input, most content from these sources can  
be passed as a non-encrypted signal to analog and digital video outputs. In a video system  
that has requirements to not transmit HDCP encrypted data (such as non-HDMI FOX  
Extenders), HDCP Authorized should be turned off at the input to keep the non-HDMI FOX  
Extenders output unencrypted.  
In the HDCP panel, select the Onradio button to enable the HDCP Authorized setting or  
select Offto disable the HDCP Authorized setting.  
NOTE: Default setting: HDCP Authorized is On.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Plus Mode Transmission panel  
Plus mode can support rates up to 1920x1200 @ 60Hz, with embedded audio, and is  
HDCP compliant. Non-Plus mode supports rates up to 1600x1200 and 1080p, is HDCP  
compliant, and does not contain embedded audio (analog audio is still supported).  
In the Plus Mode Transmission panel, click the Enabledradio button to enable Plus mode.  
To disable Plus mode, click the Disabledradio button.  
NOTE: Default setting: Plus Mode is Enabled.  
VGA Input Video Format panel  
This setting selects RGB or YUV Input Video Format for the VGA input.  
NOTE: Default setting: VGA Input Video Format is Auto.  
Audio Input Selection panel  
This panel sets the audio type for the VGA and HDMI inputs, or set them to Autofor  
automatic selection.  
For each input, select the desired audio input type from the Inputdrop-down list.  
Figure 27. Audio Input 1 Options  
NOTE: Default setting: Audio Input Selection is Autofor all inputs.  
Advanced Tab  
Figure 28. Advanced Tab  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Configuration panel  
Executive mode restricts access to the front panel button functions.  
To enable or disable executive mode, click either the Onor Offradio button in the Executive  
Mode panel.  
NOTE: Turning on Executive Mode will not disable the ability to control the device with  
the FOX Extenders Control Program.  
EDID Configuration Tab  
EDID is a data structure used to communicate video display information, including native  
resolution and vertical refresh rate requirements, to a source device. The source device then  
outputs the optimal video format for the display based on the provided EDID data, ensuring  
proper video image quality.  
To access EDID options, click the EDID Configurationtab.  
Figure 29. EDID Configuration Tab  
Assigned EDID panel  
This shows the current EDID configuration for each input. You can assign unique EDID for  
any input.  
Figure 30. Assigned EDID Panel  
Choose the desired EDID from the drop-down list of the desired input.  
NOTE: The default EDID is 720p for HDMI inputs and 1280x720 for VGA input.  
Save EDID panel  
NOTE: This setting is not available for the FOX T USW 103.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Import EDID panel  
EDID files can be imported to the FOX T USW 103 and saved in a table on the device.  
NOTE: When an EDID file is imported to a user assigned input location, the EDID is  
automatically assigned to the selected user input.  
Figure 31. Import EDID Panel  
1. In the Import EDID panel, from the drop-down list, select the desired input.  
Figure 32. Import EDID Options  
2. Click on the Browsebutton to locate and select the desired EDID file on the connected  
PC. The Open dialog box opens.  
Figure 33. Browse Button for Importing EDID  
3. Select the EDID file and click the Openbutton. The Open dialog box closes.  
4. Click the Importbutton. The EDID is imported and assigned to the selected input.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Export EDID panel  
EDID files on the FOX T USW 103 can be exported to the connected PC. To open and view  
them, use the Extron EDID Manager software, available at www.extron.com.  
The EDID Manager software aids in troubleshooting any EDID related issues that may occur  
during configuration or operation of an AV system.  
Figure 34. Export EDID Panel  
1. In the Export EDID panel, select the desired EDID to export from the drop-down list.  
2. Click the Export button. The Save As dialog box opens.  
3. Select the export destination and file name for the EDID.  
4. Click the Save button. The EDID setting is exported.  
FOX T USW 103 Universal Switcher • FOX Extender Control Program  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference  
Information  
This section provides mounting and firmware updating information. Topics in this section  
include:  
Mounting  
The FOX T USW 103 can be placed on a tabletop or mounted in a rack or underneath a desk.  
Tabletop Use  
Attach the provided rubber feet to the bottom four corners of the enclosure.  
Mounting Kits  
Mount the unit using any optional compatible mounting kit listed on the Extron website  
(www.extron.com), in accordance with the directions included with the kit. For  
rack-mounting, see UL guidelines for rack-mounted devices below.  
UL guidelines for rack-mounted devices  
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the  
FOX T USW 103 in a rack.  
1. Elevated operating ambient temperature — If installed in a closed or multi-unit rack  
assembly, the operating ambient temperature of the rack environment may be greater  
than room ambient temperature. Therefore, install the FOX T USW 103 in an environment  
compatible with the maximum ambient temperature  
(Tma = +122 ˚F, +50 ˚C) specified by Extron.  
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow  
required for safe operation of the equipment is no compromised.  
3. Mechanical loading — Mount the equipment in the rack so that a hazardous condition  
is not achieved due to uneven mechanical loading.  
4. Circuit overloading — Connect the equipment to the supply circuit and consider the  
effect that circuit overloading might have an overcurrent protection and supply wiring.  
Appropriate consideration of equipment nameplate ratings should be used when  
addressing this concern.  
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted  
equipment. Pay particular attention to supply connections other than direct connections  
to the branch circuit (e.g. use of power strips).  
FOX T USW 103 Universal Switcher • Reference Information  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Updating Firmware  
To update firmware for the FOX T USW 103, download the new firmware to a connected  
computer and upload the firmware with the Firmware Loader utility or the  
FOX Extenders Control Program (see to the FOX Extenders Control Program Help File).  
Downloading Extron Firmware Loader  
Figure 35. Firmware Loader on the Extron Website  
1. On the Extron website, www.extron.com, click the Downloadtab.  
2. From the left sidebar, click the Softwarelink.  
3. Navigate to Firmware Loader.  
4. Click the Downloadlink on the right that corresponds with the program.  
5. Submit any required information to start the download.  
Installing Firmware Loader  
1. Once Firmware Loader has been downloaded, run the .exe file from the save location.  
The installation wizard window opens.  
2. Click Nextto continue through the process, filling out necessary information and  
specifying custom settings on each prompt.  
FOX T USW 103 Universal Switcher • Reference Information  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Downloading Firmware  
Figure 36. Downloading Firmware from the Extron Website  
1. On the Extron website, www.extron.com, click the Downloadtab.  
2. From the left sidebar, click the Firmwarelink.  
3. Navigate to FOX T USW 103.  
4. Ensure the available firmware version is a later version than the current one on the  
device.  
NOTE: The firmware release notes are in a PDF file that provides details about the  
changes between different firmware versions. The file can be downloaded from the  
same page as the firmware on the Extron website, www.extron.com.  
5. Click the Downloadlink to the right of the desired device.  
6. Submit any required information to start the download. Note where the file is saved.  
7. Open the executable (.exe) file.  
8. Follow the instructions on the Installation Wizard screens to install the new firmware on  
the computer. A Release Notes file, giving information on what has changed in the new  
firmware version, and a set of instructions for updating the firmware are also loaded.  
FOX T USW 103 Universal Switcher • Reference Information  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing Firmware with Firmware Loader  
1. Open Firmware Loader to establish a connection between the computer and the device.  
The Add Device... dialog box opens.  
Figure 37. Add Device... Window  
2. Select FOX T USW 103 from the Device Namedrop-down list.  
3. Select the method of connection from the Connection Methoddrop-down list.  
4. Depending on the connection method, additional options appear. Make the appropriate  
selections for the current connection method.  
5. Click Connect.  
6. Click Browsein the New File Firmware (Optional) section.  
7. On the Open window, navigate to the new firmware file, which has an .S19 extension,  
and click Open.  
ATTENTION: Valid firmware files must have the file extension .S19. A file with  
any other extension is not a firmware upgrade for this device and could cause the  
device to stop functioning.  
8. Click Add. The Add Device... window closes and the device and firmware are listed in  
the Firmware Loader main window.  
9. Click Beginto start the upload process.  
10. Close Firmware Loader when the Remaining Timefield shows 00.00.00, the  
Progresscolumn shows 100%, and the Statusfield shows completed(see Factory  
Reset SIS commands on page 19 for reset information).  
FOX T USW 103 Universal Switcher • Reference Information  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Extron Warranty  
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years  
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty  
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,  
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is  
returned within the warranty period, with proof of purchase and description of malfunction to:  
USA, Canada, South America,  
and Central America:  
Extron Electronics  
1230 South Lewis Street  
Anaheim, CA 92805  
U.S.A.  
Japan:  
Extron Electronics, Japan  
Kyodo Building, 16 Ichibancho  
Chiyoda-ku, Tokyo 102-0082  
Japan  
Europe and Africa:  
Extron Europe  
Hanzeboulevard 10  
3825 PH Amersfoort  
The Netherlands  
China:  
Extron China  
686 Ronghua Road  
Songjiang District  
Shanghai 201611  
China  
Asia:  
Middle East:  
Extron Asia Pte Ltd  
135 Joo Seng Road, #04-01  
PM Industrial Bldg.  
Singapore 368363  
Singapore  
Extron Middle East  
Dubai Airport Free Zone  
F12, PO Box 293666  
United Arab Emirates, Dubai  
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical  
or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not  
authorized by Extron.  
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return  
Authorization) number. This will begin the repair process.  
USA: 714.491.1500 or 800.633.9876  
Asia: 65.6383.4400  
Europe: 31.33.453.4040  
Japan: 81.3.3511.7655  
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage  
during shipment. Returned units must include the serial number and a description of the problem, as well as the  
name of the person to contact in case there are any questions.  
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,  
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,  
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been  
advised of such damage.  
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may  
not apply to you.  
Extron Headquarters  
Extron Europe  
Extron Asia  
Extron Japan  
Extron China  
Extron Middle East  
Extron Korea  
Extron India  
+1.800.633.9876 (Inside USA/Canada Only)  
+800.3987.6673  
(Inside Europe Only)  
+65.6383.4400  
+65.6383.4664 FAX  
+81.3.3511.7655  
+81.3.3511.7656 FAX  
+86.21.3760.1568  
+86.21.3760.1566 FAX  
+971.4.299.1800  
+971.4.299.1880 FAX  
+82.2.3444.1571  
+82.2.3444.1575 FAX  
1800.3070.3777  
Inside India Only  
Extron USA - West  
+1.714.491.1500  
Extron USA - East  
+1.919.850.1000  
+31.33.453.4040  
+91.80.3055.3777  
+1.714.491.1517 FAX  
+1.919.850.1001 FAX  
+31.33.453.4050 FAX  
+91.80.3055.3737 FAX  
© 2013 Extron Electronics All rights reserved. www.extron.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edimax Technology Security Camera IR 123E User Manual
Extron electronic Network Card CTL208CM User Manual
Fagor America Beverage Dispenser FSV 144US User Manual
Fisher Price Car Seat EF20B User Manual
Frigidaire Microwave Oven 316495057 User Manual
Fujitsu Recording Equipment MB15F74UV User Manual
GE Microwave Oven PEB7226 User Manual
Gemini Stereo Amplifier X 01 User Manual
GE Pressure Washer WHRE5260 User Manual
Glen Dimplex Home Appliances Ltd Ventilation Hood DIH900 User Manual