Elation Professional TV Cables DP 640B User Manual

DP-640B  
R
Elation Professional  
4295 Charter Street  
Los Angeles CA. 90058  
No. 24-004-1952-00 Rev 1.0  
All Rights Reserved!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
Table of Contents  
Technical Specifications  
Power Input ..............................................................2x20A, AC 120V~50/60Hz  
Line cord..................................................................2x12AGWx3C VW-1 105 C  
Load............................................ 2400W Channels 1~3, 2400W Channels 4~6  
MCB (x2) .............................................................................................20A Each  
Dimensions ................................................19.7''x6.57''x3.66''(500x167x93mm)  
Weight(approx.) ...........................................................................7.5Ibs.(3.4 kg)  
Features ...........................................................................................1  
General Instruction..........................................................................2  
Warnings........................................................................................2  
Cautions........................................................................................ 2  
Control and Functions.................................................................... 3  
Front View......................................................................................3  
Rear View...................................................................................... 4  
LED-display & Control buttons...................................................... 4  
Dimensions in detail: (mm)  
Front  
Operation Guide.............................................................................. 5  
Function Mode 1: DMX Address (001~512)................................... 5  
Function Mode 2: Patch Address (001~512)..................................6  
Function Mode 3: Local Control (000~100)....................................7  
Function Mode 4: Dimmer/Switch.................................................. 8  
Operation, Installation & Connections...........................................9  
PANIC dip-switches 1~6................................................................9  
Installation/Mounting......................................................................9  
Connections...................................................................................9  
Troubleshooting............................................................................10  
Side 1  
Side 2  
Technical Specifications ..............................................................11  
Side 3  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
Troubleshooting  
Thank you for purchasing the DP-640B hybrid pack. This product includes the  
following features:  
Troubleshooting  
No Power to the pack:  
6 channel hybrid pack with dual Edison sockets per channel.  
3 & 5 pin XLR inputs and outputs.  
Disconnect the main power line cord. Reconnect the line cord to ensure  
proper connection. If the problem still persists, check the building service  
panel and make sure the circuit breakers are in the ON position.  
Each channel can be assigned to Dim or Switch modes.  
No Channel output:  
Disconnect the main power line cords. Check the circuit breakers to  
ensure the are in the ON position. Reconnect line cords. If controlling via  
DMX, ensure that you are receiving DMX signal at the pack. Indicator in  
the display should be flashing when signal is present. If signal is not  
present, check the XLR connections from console or previous fixture in  
line. If problem still persists, replace XLR cable between previous device  
and pack and try again.  
4 function LED's for DMX Address, Patch Address, Local Control  
and Dim/Switch modes.  
On board Local Control allows for dim intensity adjustment, from  
0-100%, for each individual channel.  
Panic function dip switches.  
Dual 20A/AC120V Power line cords.  
Digital LED-display.  
Undesired 100% channel switch output:  
Flip all "PANIC" dip switches to the OFF position. If problem still persists,  
check the "LOCAL CONTROL" settings and reset channels by pressing  
the corresponding channel button two times so that the channel LED  
turns OFF. Then press the "OK" Button store the settings.  
Two 20 Amp circuit breakers.  
Every effort has been made to design dependable and reliable products. New  
products are constantly being designed to meet the needs of the entertainment  
lighting industry. Your comments regarding our products and services are  
welcome. Please send any comment to [email protected] and let us  
kanow how we can improve to better serve you.  
If you've tried the above and the unit continues to malfunction, please  
contact ELATION customer service at (323) 582-3322, your unit will  
require service. Once you describe your problem to the customer service  
representative, you will be issued a return authorization number that  
must accompany the package when sent in. Please write this RA# on the  
outside of the box with a black marker and also write it on any packing  
list that may be included with the package.  
It is both a privilege and a pleasure to serve you.  
1
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
General Instruction  
PANIC dip-switches 1~6:  
This is a 6 channel portable dimmer/pack. Each channel can individually  
be set to dim or switch as well as accept separate DMX Addresses. For  
your convenience, each channel can manually be controlled via our  
simple to use, digital display and function buttons. The Panic function  
allows you to select desired channels to switch ON constantly via the six  
dip switch settings. The unit is also supplied with 3 & 5 pin XLR  
connectors. The aluminum case makes the DP-640B one the lightest  
portable dimmers of its kind.  
The Panic feature allows you to select desired channels, via dip switches 1-6, to  
be constantly on.  
Flip the dip switches of the desired channels to the "ON" position.  
PANIC  
The selected channels will output 100%. Note: When operating  
ON  
ON  
MD  
with DMX control, corresponding channels, with dip switches set  
to "ON", will output 100% while channels with dip switches set to  
the "OFF" position can be controlled from the DMX console.  
1 2 3 4 5 6  
To optimize performance of this product, please read these instructions  
carefully to familiarize yourself with the basic operations.  
Installation / Mounting  
Warnings  
Be sure that this unit is properly grounded.  
The DP-640B was designed to be mounted or free standing. It is recommended  
that you use a suitable mounting clamp and safety cable when mounting clamp  
and rigging to a truss structure. There are two sets of threads on the DP-640B.  
They are in place for the mounting bracket. Use the bracket knobs and washers to  
secure the mounting bracket to either side of the pack. For cooling purposes,  
it is necessary to mount the pack so that air is free to circulate around the dimmer.  
There should be at least 12 inches of clearance between the pack and anything  
surrounding it.  
Keep this unit dry, do not expose it to water or high levels of humidity.  
Do not allow for any flammable liquids to come in close contact with this  
unit.  
Handle this unit carefully, any strong shocks or vibration may result in  
damage.  
Do not operate this unit if the internal components are exposed.  
Only use an AC source that complies with the local building and electrical  
codes.  
Connections  
Cautions  
The DP-640B is supplied with dual 20 Amp Edison plugs attached to 12 gauge  
line cords. These cords should be connected to a service capable of suppling  
20 amps per line cord and be protected by a properly sized main circuit breaker.  
Lamp loads should be plugged into the dual 20 Amp Edison sockets which are  
supplied on the face of the pack. 3 & 5 pin XLR's are supplied for the DMX input  
and output of the data link. Connect out of the DMX controller orprevious fixture  
in line and into the input of the DP-640B. Connect out of the DP-640B and into  
the input of next pack or fixture in line. It is recommended that the last pack or  
fixture in line include a DMX terminator into the output. A DMX terminator  
consists of a 120 ohm, 1/4 watt resistor soldered across pins 2 & 3 of a standard  
3 or 5 pin XLR connector.  
When unpacking, please check the unit for the damages. Should you find  
something wrong with the unit, please contact the dealer that you  
purchased it from immediately.  
All rights reserved. No part of this manual may be reproduced, in any form  
or by any means, without permission in writing from Elation Professional.  
Notice:  
Specifications and improvements in the design of this product and this  
manual are subject to change without written prior notice.  
2
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Control and Functions  
Operation Guide  
Overall Layout  
Function Mode 4: Dimmer/Switch  
1
This menu option allows you to set the pack's channels to dim or switch. Each  
channel can be individually set to do one or the other. When a channel is set to  
switch, then that channel will activate when the channel level exceeds 50%.  
When a channel is set to dim, then that channels intensity can manually  
be adjusted from 0 to 100%.  
8
7
Press the MENU button until the "Dimmer/Switch"  
PANIC  
1
2
3
4
5
6
ON  
MD  
LED illuminates. The display will read either "  
1
2
3
4
5
6
" or " " depending on the current  
2
DMX Address  
DMX Signa l  
6
OK  
setting. The "C" indicates "Channel". The number  
that follows is the pack's channel number. The "d"  
indicates "Dim" and "S" indicates "Switch". In the  
example to the left, it shows channel 1 is  
currently set to dim.  
Patch Address  
Local Control  
4
Dimmer / Switch  
MENU  
1
2
3
4
5
6
3
5
9
PANIC  
1
2
3
4
5
6
ON  
MD  
4
1. Edison Output Sockets(1~6):  
1
2
3
4
5
6
(1) Select the channel that you wish to assign by  
selecting from buttons 1-6. Only one channel  
can be assigned at a time.  
These are dual 120V Edison sockets for output. Each socket is labeled  
with the relevant channel number. Up to 20Amps can be connected into  
DMX Address  
DMX Signa l  
OK  
PatchAddress  
Local Control  
each channel.  
Dimmer / Switch  
2. Threaded Openings:  
These openings are supplied so the user can fasten the mounting bracket to  
the desired side.  
MENU  
1
3
4
5
6
3. Bracket Knobs:  
These knobs are used to fasten the hanging bracket to the chassis.  
4. Resetable Circuit Breakers(x2pcs):  
PANIC  
ON MD  
1
2
3
4
5
6
1
2
3
4
5
6
These two 20A circuit breakers, protect the corresponding internal  
components from damage if there were ever a short circuit or voltage spike.  
5. Mounting Slots:  
DMX Address  
PatchAddress  
(2) Press the UP/ Down button to change the  
current setting. d="Dim"/s="Switch"  
DMX Signa l  
K  
Local Control  
Dimmer / Switch  
These slots are in place so the user could permanently mount the unit if  
desired.  
6. Connectors:  
MENU  
1
2
2
3
3
4
4
5
6
6
These are the DMX Input/Output connectors. There are 3 & 5 pin XLR inputs  
and outputs.  
PANIC  
1
5
ON  
MD  
7. Control Section:  
These buttons are used to adjust relevant settings within the display.  
8. Mounting Bracket:  
This mounting bracket is used to fasten the unit to a truss structure.  
9. Power Inputs:  
(3) Press "OK" button to confirm and save your  
setting. The display will momentarily flash  
confirming that your setting was stored.  
Repeat steps 1, 2 and 3 to assign additional  
channels. These settings will be stored to  
memory.  
1
2
3
4
5
6
DMX Address  
Patch Address  
DMX Signa l  
OK  
Local Control  
Dimmer / Switch  
These supply power to the relevant channels when connect. Line cord 1  
supplies power to channels 1-3 and line cord 2 to channels 4-6.  
MENU  
1
2
3
4
5
6
3
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Control and Functions  
Function Mode 3: Local Control (Manual)  
Data & Power Connections  
1
2
The Local Control option allows for manual control of the packs six channels via  
the on-board buttons.  
1. DMX IN:  
3 & 5 Pin (male) input socket.  
2. DMX OUT:  
PANIC  
ON MD  
1
2
3
4
5
6
3 & 5 Pin (female) output socket.  
1
2
3
4
5
6
Press the MENU button until the "Local Control'  
3. Power 1:  
LED illuminates. The display will read  
This means that channel 1 output level is  
currently set to 0.  
.
DMX Address  
Patch Address  
DMX Signa l  
OK  
Power cord 1- powers channels  
1~3, 2400 watts.  
Local Control  
Dimmer / Switch  
4. Power 2:  
M
1
2
3
4
5
6
Power cord 2- powers channels  
4~6, 2400 watts.  
3
4
PANIC  
ON  
1
2
3
4
5
6
MD  
LED-display & Control buttons  
1
2
3
4
5
6
(1)  
Select the channel that you wish to manually  
control by selecting from buttons 1-6. Only one  
channel can be selected at a time.  
DMX Address  
DMX Signa l  
OK  
Patch Address  
Local Control  
1. LED-display: displays the current  
value and function mode-including  
a DMX signal indicator.  
Dimmer / Switch  
12  
11  
MENU  
1
3
4
5
6
2. DMX Address LED: this LED  
illuminates when in DMX mode.  
3. Patch Address LED: this LED  
illuminates when in Patch mode.  
4. Local Control LED: this LED  
illuminates when in Manual  
Control mode.  
5. Dimmer/Switch LED: this LED  
illuminates when assigning dim/  
switch modes.  
PANIC  
ON MD  
1
2
3
4
5
6
1
2
3
4
5
6
1
PANIC  
ON MD  
1
2
3
4
5
6
10  
DMX Address  
PatchAddress  
DMX Signa l  
2
OK  
1
2
3
4
5
6
9
3
Local Control  
Dimmer / Switch  
4
5
(2) Press the UP/ Down button to adjust the dim  
value to your desired setting. The dim range  
is from 000 to 100%.  
DMX Address  
Patch Address  
DMX Signa l  
8
K  
Local Control  
Dimmer / Switch  
MENU  
1
2
3
4
5
6
MENU  
1
2
3
4
5
6
6
7
6. Menu Button: The menu button allows you navigate through function modes.  
7. Channel Buttons 1~6: These buttons are used to select relevant channels.  
8. Down Button: This button decreases values and selects desired function  
modes.  
9. OK Button: This button confirms and saves relevant settings.  
10. UP Button: This button increases values and selects desired function modes.  
11. Channel 1~6 LEDs: Indicate output for relevant channels.  
12. Panic dip-switches: These switches are used to activate selected channels  
to full ON when DMX signal is not present.  
(3) Press the "OK" button to confirm and save  
your setting, the display will momentarily flash  
confirming that your setting was stored.  
Repeat steps 1, 2 and 3 to manually set  
additional channel levels and store them.  
These settings will be stored to memory until  
you dis-engage the set channels.  
PANIC  
ON MD  
1
2
3
4
5
6
1
2
3
4
5
6
DMX Address  
Patch Address  
DMX Signa l  
OK  
Local Control  
Dimmer / Switch  
MENU  
1
2
3
4
5
6
4
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Operation Guide  
*Note: Abbreviations within the display represent the following:  
A=Address, C=Channel, d= Display, s=Switch.  
Function Mode 2: Patch Address (Individual)  
Press the MENU button to navigate through the menu options. Continually  
pressing the MENU button will loop through the four options as illustrated below.  
When in each function mode, its LED will illuminate.  
Press the MENU button until the Patch Address  
LED illuminates. The display will show you the  
current patch setting for channel 1. For example,  
if channel 1 was set to DMX channel 82, the  
PANIC  
ON MD  
1
2
3
4
5
6
1
2
3
4
5
6
Press  
Press  
Press  
DMX Address  
DMX Address  
Patch Address  
Local Control  
Dimmer/Switch  
DMX Signa l  
Menu button  
Menu button  
Menu button  
OK  
display would read the following:  
. The  
Patch Address  
Local Control  
number 1 in the display indicates channel 1 of  
the pack. The next three digits indicate the  
current DMX address for the selected channel.  
Dimmer / Switch  
M
1
2
3
4
5
6
Function Mode 1: DMX Address (Block)  
Note: If you set a starting DMX address channel in the DMX address option,  
channel one from the pack will assume that address channel and channels 2  
through 6 will automatically be assigned a sequential DMX channel based on  
the channel 1 address.  
PANIC  
ON MD  
1
2
3
4
5
6
(1) This function is used when setting the starting  
DMX address channel for the pack. Use the  
UP/DOWN buttons to adjust to a desired  
setting. The selected DMX channel will be the  
DMX starting address for the pack. A total of  
six DMX channels will be occupied by the  
DP-640B in sequence, starting with the set  
channel.  
1
2
3
4
5
6
DMX Address  
Patch Address  
DMX Signa l  
K  
Local Control  
PANIC  
ON MD  
1
2
3
4
5
6
Dimmer / Switch  
1
2
3
4
5
6
(1)  
Select a channel button that you want to  
address. Use the UP/DOWN button to  
adjust the channel setting. The address  
can be set anywhere between 001-512.  
MENU  
1
2
3
4
5
6
DMX Address  
DMX Signa l  
OK  
Patch Address  
Local Control  
Dimmer / Switch  
MENU  
1
3
4
5
6
PANIC  
ON MD  
1
2
3
4
5
6
1
2
3
4
5
6
(2) Press the "OK" button to confirm and save  
your setting, the LED-display will momentarily  
flash confirming that your address was stored.  
DMX Address  
DMX Signa l  
OK  
PANIC  
ON MD  
1
2
3
4
5
6
Patch Address  
Local Control  
1
2
3
4
5
6
Dimmer / Switch  
(3) Press the "OK" button to save your setting.  
The display will momentarily flash confirming  
that your patch setting has been stored. Repeat  
setp1 & 2 to patch additional channels.  
DMX Address  
DMX Signa l  
OK  
Patch Address  
MENU  
1
2
3
4
5
6
Local Control  
Dimmer / Switch  
MENU  
1
2
3
4
5
6
6
5
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Drill X750 005 05 7 User Manual
Fender Car Speaker 412 SL User Manual
Fisher Price Model Vehicle G5779 User Manual
Fostex Speaker dome tweeter User Manual
Furuno Marine RADAR FAR 2157 BB User Manual
GBC Air Compressor CC055 User Manual
GE Convection Oven 164D3333P095 User Manual
GE Kitchen Grill 106668 User Manual
GE Microwave Oven WES0930 User Manual
Gemini Turntable PT 1000 II User Manual