Elation Professional Boating Equipment E Spot LED User Manual

E Spot Led™  
Elation Professional  
6122 S Eastern Ave  
Los Angeles, Ca 90040  
Rev. 3/11/2010 – visage  
Version 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
CONTENTS  
1. General Information……………………………………………………………………… 4  
a. Introduction………………………………………………………………………. 4  
b. Unpacking………………………………………………………..…………..….. 4  
c. Customer Support…………………………………………….………………… 4  
d. Warranty Registration……………………………………………………..……. 5  
2. Safety Instructions………………………………………………………........…………. 6  
3. Features……………………………………………………………………………………7  
4. General Guidelines………………………………………………………………………. 8  
5. Fixture Overview…………………………………………………………………………. 9  
6. Mounting and Installation………………………………………………………….……..12  
a. Mounting Positions……………………………………………………………… 12  
b. Mounting Points…………………………………………………………………. 13  
c. Securing………………………………………………………………………….. 14  
7. Understanding DMX……………………………………………………………………... 15  
a. DMX Cable Requirements……..………………………………………………. 15  
b. DMX Terminator………………………………………………………………….17  
c. 3-Pin to 5-Pin Conversion……………………………………………………….17  
8. Fixture Menu……………………………………………………………………………… 19  
a. Menu functions………………………………………………………………….. 21  
9. DMX Addressing..…………………………………………………………….. ………….29  
10. DMX Channel Traits…...….…………………………………………………………….. 38  
a. DMX Channel Values…………………………………………………………… 39  
11. Error Codes………………………………………………………………………………. 41  
12. Cleaning and Maintenance……………………………………………………………42  
13. Photometric Data………………………………………………………………………….43  
14. Gobos  
15. Dimensional Drawings………………………………………………….……………….. 45  
16. Circuit Schematic………...……………………………………………………………….46  
17. Technical Specifications…………………………………………...………….………… 49  
©Elation Professional, Los Angeles Ca.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
1. GENERAL INFORMATION  
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and  
reliable lighting fixtures on the market today! The E Spot Led,has been designed to  
perform reliably for years when the guidelines in this booklet are followed. Please read and  
understand the instructions in this manual carefully and thoroughly before attempting to  
operate this unit. These instructions contain important information regarding safety during  
use and maintenance.  
UNPACKING: Thank you for purchasing the E Spot Ledby Elation Professional®. Every E  
Spot Ledhas been thoroughly tested and has been shipped in perfect operating condition.  
Carefully check the shipping carton for damage that may have occurred during shipping. If  
the carton appears to be damaged, carefully inspect your unit for damage and be sure all  
accessories necessary to operate the unit have arrived intact. In the event damage has been  
found or parts are missing, please contact our customer support team for further assistance.  
Please do not return this unit to your dealer without first contacting customer support at the  
number listed below.  
Inside the box you should find: the E Spot, a DMX cable, a safety cable, two omega clamps  
and this manual. Please contact customer support at the number listed below if any items  
are missing.  
During initial fixture start-up, the fixture may omit some light smoke or release a  
slight burning smell. This is a normal process and should decrease gradually.  
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide  
set up help and to answer any question should you encounter problems during your set up  
comments or suggestions. For service related issue please contact Elation Professional®.  
Service Hours are Monday through Friday 8:00 a.m. to 5:00 p.m. Pacific Standard Time.  
Voice:  
Fax:  
(323) 582-3322  
(323) 832-9142  
E-mail:  
Forum:  
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to  
©Elation Professional, Los Angeles Ca.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
rain or moisture.  
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs  
yourself, doing so will void your manufactures warranty.  
Please do not discard the shipping carton in the trash. Please save for return shipping in the  
event service is ever needed or recycle the container whenever possible.  
WARRANTY REGISTRATION: The E Spot Ledcarries a two year (730 days) limited  
warranty. Please fill out the enclosed warranty card to validate your purchase. All returned  
service items whether under warranty or not, must be freight pre-paid and accompany a  
return authorization (R.A.) number. The R.A. number must be clearly written on the outside  
of the return package. A brief description of the problem as well as the R.A. number must  
also be written down on a piece of paper and included in the shipping container. If the unit is  
under warranty, you must provide a copy of your proof of purchase invoice. Items returned  
without a R.A. number clearly marked on the outside of the package will be refused and  
returned at customer’s expense. You may obtain a R.A. number by contacting customer  
support at (323) 582-3322.  
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the light  
source at all times.  
Never open this fixture while in use!  
This device falls under protection-class 1. Therefore it is essential that the device be  
grounded properly.  
All electrical connections must be performed by qualified personal.  
Be sure the available voltage matches the voltage requirements of the unit.  
Be sure the power cord is never crimped or damaged. If the power cord is damaged, replace  
it immediately with a new one of similar power rating.  
Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of  
the cord.  
©Elation Professional, Los Angeles Ca.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
2. SAFETY INSTRUCTIONS  
The E Spot Ledis an extremely sophisticated piece of  
electronic equipment. To guarantee a trouble free operation, it is  
important to follow the guidelines in this manual. Elation will not  
accept responsibility for damages resulting from the misuse of  
this fixture due to the disregard of the information printed in this  
manual.  
1. Always be sure that the fan and the air inlets remain clean and are never blocked.  
Allow about 6” (15cm) between this fixture and other devices or a wall to allow for  
proper cooling.  
2. Never touch the fixture during normal operation. This can cause severe personnel  
injuries and/or damage to the fixture.  
3. Be sure to unplug the E Spot Ledfrom the power outlet before performing any  
service or cleaning related issues.  
4. Never look directly into the light source. You risk injury to your retina, which may  
induce blindness.  
5. For safe operation, follow the Installation guide described in chapter two of this  
manual. Operating the E Spot Ledwithout suited safety aids such as safety  
cables or clamps can increase the risk of damage and/or personal injury.  
6. When mounting this fixture, use only the original rigging parts included with this  
fixture. Any structural modification will void the original manufactures warranty and  
may increase the risk of damage and/or personal injury.  
7. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture.  
8. Do not attempt to operate this fixture if the power cord has become damaged or  
frayed.  
9. Installation should only be performed by qualified and certified personal.  
Important Notice: Damages resulting from the disregard of safety and general user  
instructions found in this user manual are not subject to any warranty claims.  
©Elation Professional, Los Angeles Ca.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
3. FEATURES  
Pan 540° or 630˚ (User selectable) / Tilt 270°  
15˚ Beam Angle  
Low Power Consumption  
60 WATT White LED Source (Over 2,200 lumens from a single chip)  
60,000 hours rated LED life  
Color Wheel: 8 colors plus white, with rainbow effect  
Rotating gobo wheel with 7 rotating gobos plus open, all gobos can be easily  
replaceable and gobo indexing  
Prism and Prism Rotation, with 16 prism macros (Indexable)  
Flicker-free operation for television and film  
3 operation mode: DMX controlled, stand alone or sound activated  
Strobe effect: 0~18 flashes per second or random strobe  
0%~100% Dimming (two dimming options; linear & standard)  
Electronic menu display  
Control board with full LCD character display and foil-keyboard  
RDMX (Remote DMX addressing from any DMX console)  
Auto test for all functions  
Automatic Pan/Tilt Correction  
USITT DMX-512 Complaint (3-pin and 5-pin DMX Connections)  
Value of each DMX-channel can be displayed  
Minimal heat emission  
Maintenance free operation  
Preprogrammed colored macros  
Electronic power supply (100v~240V 50/60Hz)  
8 built-in programs accessed via DMX-controller or manually  
Built-in DMX recorder - via the control board or external controller, up to 64 scenes  
can be saved and then can be run in Stand Alone or sound activated.  
©Elation Professional, Los Angeles Ca.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
4. GENERAL GUIDELINES  
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in  
theatres, etc. Do not attempt operation or installation without a proper knowledge on how to  
do so.  
This fixture was designed for indoor use only.  
Consistent operational breaks may ensure that the fixture will function properly for many  
years to come.  
Do not shake the fixture around. Avoid brute force when installing or operating the device.  
While choosing an installation location, please be sure that the fixture will not be exposed to  
extreme heat, moisture or dust. The minimum distance between the fixture and a wall or flat  
surface should be at least 0.5 meter (about 1.5ft).  
Always install the fixture with an appropriate safety cable. When installing the fixture in a  
suspended environment always be sure to use mounting hardware no less than M10 x 25  
mm, also be sure the hardware is insert in the pre-arranged screw holes in the base of the  
fixture.  
When using the quick release “Omega” cam-lock system, be sure the four quick lock  
fasteners are locked in the quick lock holes correctly.  
Do not attempt to operate this fixture until you have familiarized yourself with its functions.  
Do not permit operation by persons not qualified for operating this type of theatrical fixture;  
most damages are the result of operations by nonprofessionals.  
Please use the original packaging to transport the fixture in for service.  
©Elation Professional, Los Angeles Ca.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
5. FIXTURE OVERVIEW  
1. LED Assembly  
2. LCD Menu Display  
3. Mode/Esc Button  
4. Up Button  
5. Down Button  
6. Enter Button  
7. Microphone  
8. Carrying Handle  
9. 3-Pin DMX Output  
10. 3-Pin DMX Input  
11. 5-Pin DMX Output  
12. 5-Pin DMX Input  
13. Power Switch  
15. Fuse Holder  
16. Power Cord  
©Elation Professional, Los Angeles Ca.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
1. LED–Extremely high optical LED output, Over 2,200 lumens from a sin-gle chip (White)  
2. LED Menu Display - 4-segment menu display. Used to display the DMX address as  
well as all other menu functions.  
3. Mode/Esc Button - This button is used to access the menu functions.  
4. Up Button – The up button is used to toggle forward through the menu functions and  
settings.  
5. Down Button – The down button is used to toggle backwards through the menu  
functions and settings.  
6. Enter Button – The enter button is used to enter in to a certain menu function or to lock  
a function into memory.  
7. Microphone Internal microphone is used to trigger built-in scenes to sound.  
8. Carrying Handle – Please use this intergraded handled to move the fixture form  
location to location. Never carry the fixture by the head.  
9. 3-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next  
fixture in the DMX chain via a female, 3-pin XLR jack.  
10. 3-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 3-pin  
XLR jack.  
11. 5-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next  
fixture in the DMX chain via a female, 3-pin XLR jack.  
12. 5-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 5-pin  
XLR jack.  
©Elation Professional, Los Angeles Ca.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
13. Power Switch Controls main power to the unit.  
14. Fuse Holder Assembly – This assembly houses the 4amp GMA safety fuse. Always  
replace the fuse with an exact match unless otherwise specified by an authorized Elation  
Service Technician. Using a fuse other than that specified could seriously damage the  
unit and will void your manufactures warranty.  
15. Power Cord – Plug into an appropriate power outlet to provide main power to the  
fixture.  
©Elation Professional, Los Angeles Ca.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
6. MOUNTING AND INSTALLATION  
Cautions:  
For added protection mount the fixtures in areas outside walking paths, seating areas, or in  
areas were the fixture might be reached by unauthorized personal.  
Before mounting the fixture to any surface, make sure that the installation area can hold a  
minimum point load of 10 times the device’s weight.  
Fixture installation must always be secured with a secondary safety attachment, such as an  
appropriate safety cable.  
Never stand directly below the device when mounting, removing, or servicing the fixture.  
Caution!  
When install the fixture be sure there is no highly inflammable  
material within a distance of .5m (1.5 feet)  
Mounting  
The E Spot Ledis fully operational in two different mounting positions, hanging  
upside-down from a ceiling, or set on a flat level surface (see illustration on the next page).  
Never mount the fixture on its’ side in any type of installation. Be sure this fixture is kept at  
least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). Always use and  
install the supplied safety cable as a safety measure to prevent accidental damage and/or  
injury in the event the clamp fails.  
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217  
for proper installation in Europe To ensure proper installation, only  
qualified staff should attempt installation.  
©Elation Professional, Los Angeles Ca.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
Mounting points  
Overhead mounting requires extensive experience, including amongst others calculating  
working load limits, a fine knowledge of the installation material being used, and periodic  
safety inspection of all installation material and the fixture. If you lack these qualifications, do  
not attempt the installation yourself. Improper installation can result in bodily injury.  
CAUTION!  
Be sure a qualified electrician performs all electrical  
connections.  
Be sure to complete all rigging and installation procedures before connecting the main  
power cord to the appropriate wall outlet.Clamp Mounting  
©Elation Professional, Los Angeles Ca.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
The E Spot Ledprovides a unique mounting bracket assembly that integrates the bottom of  
the base, the included “Omega Bracket,” and the safety cable rigging point in one unit (see  
the illustration below). When mounting this fixture to truss be sure to secure an appropriately  
rated clamp to the included omega bracket using a M10 screw fitted through the center hole  
of the “omega bracket”. As an added safety measure be sure to attached at least one  
properly rated safety cable to the fixture using the safety cable rigging point integrated in the  
base assembly  
Securing the E Spot Led™  
Regardless of the rigging option you choose for your E Spot Ledalways be sure to secure  
your fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable  
on the hanging bracket as illustrated above. Be sure to only use the designated rigging point  
for the safety cable and never secure a safety cable to a carrying handle.  
©Elation Professional, Los Angeles Ca.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
7. UNDERSTANDING DMX  
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most  
lighting and controller manufactures as a form of communication between intelligent fixtures  
and controllers. DMX allows all makes and models of different manufactures to be linked  
together and operate from a single controller. This is possible as long as all the fixtures and  
the controller are DMX compliant. A DMX controller sends the DMX data instructions to the  
fixture allowing the user to control the different aspects of an intelligent light. DMX data is  
sent out as serial data that travels from fixture to fixture via data “IN” and data “OUT” XLR  
terminals located on the fixtures (most controllers will only have output jacks).  
DMX Linking: To ensure proper DMX data transmission, always use proper DMX cables  
and a terminator. When using several DMX fixtures try to use the shortest cable path  
possible. Never split a DMX line with a “Y” style connector. The order in which the fixtures  
are connected in a DMX line does not influence the DMX addressing. For example; a fixture  
assigned a DMX address of 1 may be placed anywhere in the DMX chain, at the beginning,  
at the end, or anywhere in the middle. The DMX controller knows to send data assigned to  
address 1 to that fixture no matter where it is located in the DMX chain. The E Spot Led™  
can be controlled via DMX-512 protocol. The E Spot Led™ is a 14-channel DMX fixture. The  
DMX address is set electronically using the controls on the LCD menu.  
Note: Although microphone and DMX cables may look similar, they are  
not constructed of the same material and should never be used in place  
of each other.  
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your  
fixture and your DMX controller require a standard 3-pin or 5-pin XLR connector for data  
input and data output (the figure on the next page is of a 3-Pin XLR connector). If you are  
making your own cables, be sure to use two conductor shielded digital DMX cable rated at  
120 ohms; this cable is designed for DMX transmission and may be purchased from your  
Elation dealer or at most professional lighting retailers. Your cables should be made with a  
male and female XLR connector on either end of the cable. Also, remember that a DMX line  
must be daisy chained and cannot be split, unless using an approved DMX splitter such as  
©Elation Professional, Los Angeles Ca.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
the Elation Opto Branch 4™ or DMX Branch/4™.  
Be sure to follow the above figure when making your own cables. Do not use the ground lug  
on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or  
allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the  
shield could cause a short circuit and erratic behavior.  
DMX-512 control connection  
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the  
other side to the male 3-pin XLR input of the moving head (Please refer to the diagram  
below.). You can chain multiple moving heads together through serial linking. The cable that  
should be used is two conductor, shielded DMX cable with XLR input and output connectors.  
Always be sure daisy chain your in and out data connections, never split or “Y” your DMX  
connections unless you are using an approved DMX splitter such as the Elation Opto Branch  
4™ or DMX Branch/4™.  
©Elation Professional, Los Angeles Ca.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
DMX-512 connection with DMX terminator  
A DMX terminator should be used in all DMX lines especially in longer runs. The use of a  
terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt  
resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and  
DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy  
chain to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease  
the possibilities of erratic behavior.  
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA  
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX  
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must  
be used, these adaptors are readily available at most electric stores. The following chart  
details a proper cable conversion.  
Fixture DMX addressing;  
All fixtures should be given a DMX starting address when using a DMX controller, so the  
correct fixture responds to the correct control signal. This digital starting address is the  
channel number from which the fixture starts to “listen” to the digital control information sent  
©Elation Professional, Los Angeles Ca.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
out from the DMX controller. The allocation of this starting DMX address is achieved by  
setting the correct DMX address on the digital display located on the base of the fixture.  
You can set the same starting address for all fixtures or a group of fixtures, or set different  
address for each individual fixture. Be advised that setting all you fixtures to the same DMX  
address will subsequently control all fixtures in the same fashion, in other words, changing  
the settings of one channel will affect all the fixtures simultaneously.  
If you set each fixture to a different DMX address, each unit will start to “listen” to the  
channel number you have set, based on the quantity of control channels (DMX channels) of  
each fixture. That means changing the settings of one channel will only affect the selected  
fixture.  
In the case of the E Spot Led™, which is a 14 channel fixture, you should set the starting  
DMX address of the first unit to 1, the second unit to 15 (14 + 1), the third unit to 29 (14 + 15),  
and so on.  
Note: During start-up the E Spot Ledwill automatically detect whether a DMX data signal  
is being received or not. If DMX data signal is being received, the display will show  
"Addr=XXX" (XXX representing the actual DMX address). If the fixture is not receiving a  
DMX signal the display will flash. If your fixture is connected to a DMX controller and the  
display is flashing (not receiving a DMX signal), please check the following:  
-
The 3-PIN or 5-PIN XLR input plug (cable with DMX signal from controller) is not  
connected or is not inserted completely into the DMX input jack of the fixture.  
The DMX controller is switched off or defective.  
-
-
-
The DMX cable or connector is defective.  
A DMX terminator has been inserted into the last fixture in your DMX chain.  
©Elation Professional, Los Angeles Ca.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
8. FIXTURE MENU  
On-Board System Menu: The E Spot Ledcomes with an easy to navigate system menu.  
This next section will detail the functions of each command in the system menu.  
LCD Control Panel: The control panel located on the base of the fixture allows you to  
access the main menu and make all necessary adjustments to the E Spot Led™. During  
normal operation, tapping the “Mode/Esc” key once will access the fixture’s main menu.  
Once in the main menu you can navigate through the different functions and access the  
sub-menus with the Up and Down buttons. Once you reach a field that requires adjusting,  
tap the ENTER button to activate that field and use the UP and Down button to adjust the  
field. Tapping the Enter button once more will confirm your setting. Once a setting is saved  
the display will briefly readout OK to confirm a new setting has been made and locked into  
memory. You may exit the main menu at any time without making any adjustments by  
tapping the Mode/Esc button.  
MODE/ESC Button - To access the main menu locate the Mode/Esc button on the front of  
the unit. Press this button to activate the system menu. Tap the UP button until you reach  
the function you wish to change. When you reach the function you wish to change tap the  
ENTER button once to select that menu function. When a function is selected use either the  
UP or DOWN buttons to change the function. Once your changes are made tap the ENTER  
button yet again to lock the change in the system menu. To exit without making any  
changes tap the Mode/Esc button.  
Default settings shaded.  
Indicate the staring DMX address  
0
1
ADDR  
TEST  
AXXX A001  
T-01~T-XX  
RUN  
A001 also is the setting for slave  
Automatically test the function  
Runs fixture as “master” or “alone” for  
auto  
MSTR/ALON  
Runs fixture as “master” or “alone” for  
audio  
2
3
PLAY  
RESE  
AUDI  
AUTO  
ALL  
MSTR/ALON  
No DMX Status  
Clos/Hold/Auto/Audi  
Reset all motors and returns fixture to  
home  
SCAN  
COLR  
Reset only motors for pan/tilt  
Reset only motors for colors  
©Elation Professional, Los Angeles Ca.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
Reset only motors for gobo and  
rotation  
GOBO  
OTHR  
Reset other motors  
LIFE  
CLMP  
0000~9999  
Displays the total fixture running time  
Clear lamp running time  
4
TIME  
5
6
7
8
9
RPAN  
RTLT  
FINE  
DEGR  
MIC  
ON/OFF  
ON/OFF  
ON/OFF  
540/630  
M-XX M-70  
Reverses the pan movements  
Reverses the tilt movements  
Switch 16 bit/8 bit  
Pan degree select  
Mic sensitivity  
Display the DMX512 value of each  
channel  
Display turn off after 2mins  
This function will reverse the display  
180  
VALU  
D ON  
FLIP  
D–XX D-00 (DXXX)  
ON/OFF  
10 DISP  
ON/OFF  
Change DMX address via external  
controller  
Lamp optimization  
Resets all the fixture functions to  
default  
RDMX  
SPOT  
DFSE  
ON/OFF  
ON/OFF  
ON/OFF  
Pan/tilt feedback (error correction)  
on/off  
11 SPEC  
FEED  
ON/OFF  
FANS  
VER  
AUTO/HIGH/LOW  
V1.0~V9.9  
Fan’s mode select  
Software version  
CODE  
CH01~CHXX  
AUTO  
CXXX  
XXXX(-128~127)  
Srvice code is “C050”  
Motor Fix  
ADJU  
SEPR  
STEP  
Select program to be edit  
IP01~IP08  
Set the amount of your  
program  
Edit the channels of each  
scene  
Time for each scene  
Edit program via controller  
Auto Save  
S–01 ~S–48  
C–01~C–XX  
0 1 XX(00~FFH)  
XX XX(00~FFH)  
T XXX(001~999)  
ON/OFF  
12 EDIT  
SCXX  
TIME  
CEDT  
RE.XX  
ON/OFF  
REC.  
RUN  
Program test  
Main Menu Functions  
1. ADDRESS MENU  
- AOO1 - A511 (Value) - This is where you set the fixtures DMX address.  
Setting/Changing the DMX Address  
After applying power to the E Spot Led™ the LED will display the fixture’s current DMX  
address immediately after the reset sequence. If the fixture is not receiving a DMX  
signal the display will flash continuously. To set or adjust a DMX address, please follow  
the procedure below:  
©Elation Professional, Los Angeles Ca.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
1. Switch on the E Spot Led™ and wait for the fixture reset process to finished.  
2. Press the Mode/Esc button to access the main menu. Toggle through the menu by  
pressing the Up and Down buttons until the display shows A001. Tap the enter  
button to make changes to the address, the current three digit address will  
immediately begin to flash.  
3. While the current three-digit address is flashing, use the Up and Down buttons to  
select adjust the address. Lock your new address into the unit’s memory by  
pressing the Enter button. After the new address has been successfully stored into  
the fixture’s memory the LED will briefly readout PASS.  
The DMX address is non-destructible and will remain in the fixture’s memory even when  
power to the fixture has been switched off. Memory is backed-up and retained by an internal  
power source with a five year shelf life.  
2. TEST MENU  
- T-01 - T-XX (Test) - Tests the functions of channel. To enter the test menu follow  
the procedure below:  
1. Access the main menu.  
2. Tap the UP button until “TEST” is displayed, press ENTER.  
3. The display will read T-01. You can now press the up button and test the different  
channels. For example: If you press the up button until “T-05” is displayed, the unit  
will test the color channel, changing the color one by one and show the rainbow  
effect with different speeds.  
4. Press MODE/ENTER or EXIT to exit.  
3. PLAY MENU -  
RUN  
This feature is used to run the internal preset programs in either a Master/Slave  
or a stand-alone operating mode. Follow the procedure below to enter the run menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “RUN” is displayed, press ENTER.  
©Elation Professional, Los Angeles Ca.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
4. Tap the UP or DOWN button to select either “Master” or “Alone” and press ENTER.  
5. Press MODE/ESC to return to the main menu.  
AUDI  
- This feature is used to run the internal preset programs in AUDIO mode in either a  
Master/Slave or a stand-alone operating mode Follow the procedure below to enter the  
audio menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “AUDI” is displayed, press ENTER.  
4. Tap the UP or DOWN button to select either “Master” or “Alone” and press ENTER.  
5. Press MODE/ESC to return to the main menu.  
AUTO  
– Runs the unit without any DMX signal in stand-alone mode. Follow the procedure  
below to enter the auto menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “AUTO” is displayed, press ENTER.  
4. Tap the UP or DOWN button to select “CLOS”, “HOLD,” “AUTO,” or “AUDI” and  
press ENTER to confirm.  
5. Press MODE/ESC to return to the main menu.  
This function dictates how the fixture will function if it looses DMX signal during  
normal operation. The default function is set to hold, in which the fixture will lock into  
the last DMX signal it received and remain in that position until it is turned off or  
begins receiving a new DMX signal. If the fixture is turned on without any DMX  
signal, the fixture will automatically go in to sound-active mode. Available settings  
are: “Close” – Shutter flags will close. “Hold” – Fixture will remain at it’s last settings.  
“Auto” – Fixture will go into stand-alone mode, running the built-in program. “Music”  
– The fixture will go into sound-active mode.  
©Elation Professional, Los Angeles Ca.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
4. RESE (RESET) MENU -  
ALL - Resets all the motors in the unit.  
SCAN - Resets the Pan and Tilt motors.  
COLR (Color) - Resets the color motors.  
GOBO - Resets the gobo motors.  
SHTR - Resets the shutter motors.  
OTHR - Reset all other motors  
ALL  
- When you activate this reset function, the fixture will begin to reset all motors.  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “ALL” is displayed, press ENTER.  
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the  
color motor.  
5. Press ENTER to confirm  
6. Press MODE/ESC to return to the main menu.  
SCAN  
- When you activate this reset function, the fixture will only reset the Pan and  
Tilt mirror motor.  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “SCAN” is displayed, then press ENTER to confirm.  
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the  
color motor. Press ENTER to confirm.  
5. Press MODE/ESC to return to the main menu.  
COLR  
- When you activate this reset function, the fixture will only reset the color  
©Elation Professional, Los Angeles Ca.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
wheel motor.  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “COLR” is displayed, then press ENTER to confirm.  
4. The display will show “ON/OFF”. Press the UP button to selectONto reset the  
color motor. Press ENTER to confirm.  
5. Press MODE/ESC to return to the main menu.  
GOBO  
- When you activate this reset function, the fixture will only reset the gobo  
wheel motor.  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “GOBO” is displayed, press ENTER to confirm and begin  
the reset process.  
4. Press MODE/ESC to return to the main menu.  
OTHR  
- When you activate this reset function, the fixture will only reset any motor not  
specified in the other reset commands previously listed.  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “OTHR” is displayed, then press ENTER to confirm.  
4. The display will show “ON/OFF”. Press the UP button to selectONto reset the  
color motor. Press ENTER to confirm.  
5. Press MODE/ESC to return to the main menu.  
5. TIME MENU -  
LIFE - Displays the fixtures total running time.  
©Elation Professional, Los Angeles Ca.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
CLMP - Clears the lamp running time.  
LIFE  
- With this function you can display the total running time of the fixture.  
1. Access the main menu.  
2. Tap the UP button until ”TIME” is displayed, press ENTER.  
3. Tap the UP button until “LIFE” is displayed, press ENTER.  
4. Press MODE/ESC to return to the main menu.  
CLMP  
- With this function you can clear the running time of the lamp. Note: Please  
clear the lamp time every time you replace the lamp.  
1. Access the main menu.  
2. Tap the UP button until “TIME” is displayed, press ENTER.  
3. Tap the UP button until “CLMP” is displayed, press ENTER.  
4. Press MODE/ ENTER, the display will show “ON/OFF”.  
5. Press the UP button to select “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
6. RPAN MENU  
- This menu function will reverse the mirror PAN movements.  
1. Access the main menu.  
2. Tap the UP button until “RPAN” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
7. RTLT MENU  
©Elation Professional, Los Angeles Ca.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
- This menu function will reverse the mirror TILT movements.  
1. Access the main menu.  
2. Tap the UP button until “RTLT” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
8. FINE MENU  
- This menu item switches between 16 bit (fine) and 8 bit (coarse) modes. When  
this function is turned on the fixture will operate in 16 bit (fine) mode. When functioning in 16  
bit mode the fixture will use 16 DMX channels, when the 16bit function is turned off the  
fixture will use 14 DMX channels. To access the Fine menu follow the procedure below:  
1. Access the main menu.  
2. Tap the UP button until “FINE” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
9. DEGR MENU -  
- This menu function will toggle between the 630°and 540°for pan movement  
When this function is turned on, the fixture will operate with a pan movement of 540˚.  
1. Access the main menu.  
2. Tap the UP button until “DEGR” is displayed, press ENTER.  
3. The display will display “630/540”.  
4. Press the UP or DOWN button to select 630˚ or 540˚ for the pan movement angle,  
the default is 540˚  
5. Press ENTER to confirm.  
©Elation Professional, Los Angeles Ca.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
6. Press MODE/ESC to return to the main menu.  
10. MIC MENU  
- This function allows for electronic control of the internal microphone’s sound  
sensitivity.  
1. Access the main menu.  
2. Tap the UP button until “MIC” is displayed and press ENTER.  
3. The display will show “M-XX” (Where XX represents a value between 00 & 99).  
4. Use the UP and DOWN button to adjust the mic sensitivity, 99 being the highest.  
5. Press ENTER to confirm and lock your new setting in place.  
6. Press MODE/ESC to return to the main menu.  
11. DISPLAY MENU  
- This menu function will control the various on-board display features.  
VALU – This function will display the DMX value of each channel as it is  
adjusted through the use of a DMX console.  
1. Access the main menu.  
2. Tap the UP button until “DISP” is displayed.  
3. Press ENTER, the display will show “VALU”.  
4. Press ENTER, once again “d-00” will be displayed.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
D ON – This function will turn the display off after the has gone two seconds  
without any menu activity.  
1. Access the main menu.  
2. Tap the UP button until “DISP” is displayed.  
3. Press ENTER, the display will show “VALU”.  
4. Tap the UP button until ”D-ON” is displayed and tap the ENTER button.  
Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this  
function. When set “OFF”, this function will turn the display off after the display has gone  
©Elation Professional, Los Angeles Ca.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
two seconds without any menu activity.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
FLIP – This function will reverse the display readout buy 180˚.  
1. Access the main menu.  
2. Tap the UP button until “DISP” is displayed.  
3. Press ENTER, the display will show “VALU”.  
4. Tap the UP button until ”FLIP” is displayed and tap the ENTER button.  
5. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
13. SPEC MENU – This menu option access all the special functions listed below.  
RDMX - Allows DMX address to be changed via and external DMX controller.  
SPOT - This provides a spot beam for better lamp optimization.  
DFSE (Default) - Resets the unit to all default settings.  
FEED - This function turn the DMX correction feature “ON” (default) or “OFF.”  
FANS- Changes the functionality of the built-in fans.  
VER (Version) - Displays the software version.  
ADJU – Calibration functions  
RDMX  
– This function allows the DMX address to remotely be adjusted from a DMX  
console. This setting requires special settings for both the controller and the fixture.  
RDMX is on by default. Follow the procedure listed below to access the RDMX  
functions:  
Fixture Settings:  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “RDMX” is displayed, press ENTER.  
©Elation Professional, Los Angeles Ca.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
Controller Settings:  
1. Set the DMX value of channel 1 to a value of 7.  
2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7"  
you can adjust the starting address between 1 and 255. When set to "8" you can  
adjust the starting address between 256 and 511.  
3. Use channel 3 to set your desired DMX starting address. For example: If you  
want to set the starting address to 57, set channel 1 to a value of “7,” set channel  
2 to a value of “7” and use channel 3 to set your address to 57 by selecting a  
channel value of 57. Example 2: If you want to set the starting address to 420, set  
channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164"  
(256+164=420).  
4. Wait for approximately 20 seconds for the unit to complete the address  
reset function.  
SPOT  
– This function allows you to optimize the lamp without the use of an external  
DMX controller. In this mode, the device will not react to any control signal.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “DFSE” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
©Elation Professional, Los Angeles Ca.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
DFSE  
- With this function you can restore the factory default settings of the fixture. All  
settings will be set back to the default values. Any edited scenes will be lost. When  
restoring the factory settings the unit must be set to the address that the unit was in  
when you started editing. When you confirm this function, the fixture will begin to  
reload the original factory settings.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “DFSE” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
FEED  
- Use this function to activate the pan/tilt error correction.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “FEED” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
FANS  
- This function is used to change the functionality of the internal cooling fans.  
Follow the procedure below to access the fan menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “SPEC” is displayed, press ENTER.  
©Elation Professional, Los Angeles Ca.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
3. Tap the UP or DOWN button until “FANS” is displayed, press ENTER.  
4. The display will show “HIGH/AUTO”.  
5. Press UP or DOWN button to select “HIGH” or “AUTO”.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
VER  
- Use this function to display the Software version of the unit.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “VER” is displayed, press ENTER.  
4. The display will show “V-1.0,” the display may also show, “V-2.0,” “V-9.9” etc.  
5. Press ENTER or MODE/ESC to exit.  
ADJU  
- This function is used to calibrate the various internal motors in the event the  
internal homing mechanism become slightly out of adjustment. This function is protected  
with a password to prevent unauthorized personal from tampering with the fixture. To  
enter the calibration menu follow the steps below:  
1. Access the main menu.  
2. Tap the UP or DOWN buttons until “ADJU” is displayed, then press ENTER.  
3. Tap the UP or DOWN buttons until “CODE” is displayed, then press ENTER.  
4. The display will show “CXXX”, were as XXX represents the calibration password.  
The calibration password is “C050.” Use the UP or DOWN buttons to enter the  
proper password.  
5. Once the proper password is entered the display will read “CHXX”, were as “XX”  
represents the fixture channel number, in the case of the E Spot Led™ 1 ~ 16.  
6. Select the desired channel to be calibrated by pressing the UP or DOWN  
buttons and then ENTER to confirm.  
7. The display will then read “xxxx”, were “xxxx” stands for the calibrate values.  
8. Adjust the desired calibration value between –128 and 127 by pressing the UP  
and DOWN. As you scroll up and down through the calibration values you will  
notice slight changes in the wheel or motor you are attempting to calibrate.  
©Elation Professional, Los Angeles Ca.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
9. Once you reach your desired calibration press ENTER to confirm and lock in  
your calibration.  
14. EDIT MENU  
- This menu item allows you to write a program into the fixture’s internal memory  
(EEPROM) via the control panel or via an external DMX controller.  
SEPR- Select program to be edit.  
STEP (S-01 - S-48) - These are the steps slots that you write your programs into. There  
are at total of 48 steps.  
STXX (SC01 – SC48) - These are the scenes that are stored in your program. There are a  
total of 48 scenes. C-01 - C-11 (Channel 1 - Channel 11) – Represents the total fixture  
channels for each scene that can be edited.  
TIME (Time) - Running time of the entire program.  
CEDT - Edit program using a external controller.  
REC – Auto save function.  
RUN – Program test mode.  
REC  
- Records scenes automatically from any external DMX controller and stores them  
inside the fixtures built-in memory. These scenes can then be recalled without the use of  
an external controller.  
1. Access the main menu.  
2. Tap the UP or DOWN buttons until “EDIT” is displayed, then press ENTER.  
3. Tap the UP or DOWN buttons until “REC” is displayed, then press ENTER.  
4. After entering the REC function the display will read “RE.XX,” where as “XX”  
represents the scene number in the internal memory to which the scene will be  
stored.  
5. Press the UP or DOWN buttons to select the desired scene number.  
6. When you reach the scene number you wish to store the scene to, press ENTER  
to confirm and lock the scene into the fixture’s memory.  
7. Press MODE/ESC to return to the main menu.  
©Elation Professional, Los Angeles Ca.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
SEPR  
- With this function you can Select program to be edit.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “SEPR” is displayed, press ENTER.  
4. The display shows “IP01,” this indicates the first step of your program. You can  
call up to “IP08” scenes in “AUTO.” For example.  
5. Press ENTER to save and MODE/ESC to exit.  
STEP  
- With this function you can program the number of steps in your individual  
Program.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “STEP” is displayed, press ENTER.  
4. The display shows “S-01,” this indicates the first step of your program. You can  
call up to 48 scenes in “Run.” For example; if “S-05” is displayed, it means that  
the scene will “RUN” the first 5 scenes you saved in “Edit.”  
5. Press ENTER to save and MODE/ESC to exit.  
SC01  
- This function allows you to choose the total number of scenes in your internal  
program.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “SC01” is displayed.  
4. The display indicates “SC01,” this stands for the first scene of your program.  
You may recall up to 48 scenes. For example, if you choose “SC05,” and then  
select the “Run” function, the first 5 scenes you saved in “Edit” mode will run.  
5. Press ENTER to save and MODE/ESC to exit.  
©Elation Professional, Los Angeles Ca.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
Editing procedure 1: Using the control board only.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed and press ENTER.  
3. The display will show “SC-01”, this stands for the scene number. For example,  
“SC-01” is displayed, it means you will be editing scene 1, press ENTER. You  
can change the scene number by tapping the UP button.  
4. Press ENTER, the display will show “C-01,” this represents the channel number.  
If “C-01is displayed, you will be editing the fixture’s channel 1 value of the  
selected scene, press ENTER. You can change the channel number by tapping  
the UP button.  
5. The display will show the DMX value for the channel that is being edited. It will be  
displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX  
value is “XX.”  
6. Adjust the DMX value by tapping the UP button, until you get the expected effect  
for this channel.  
7. Press ENTER to enter the editing of the other channels of the scene.  
8. Repeat steps 5-8, until you finish setting all the DMX values for all the channels  
of this scene, each scene can have 16 channels maximum.  
9. Once all the channels are completed, the display will begin to flash “TIME,” this  
indicates the time needed to run this scene.  
10.Press ENTER to edit the time needed, the display shows TXXX, XXX”  
represents the time needed to run this scene. For example, T002means  
scene 1 needs 0.4 seconds to run,T-15means this scene needs 3.0 seconds  
to run. Note: “XXis always 0.2 seconds not one second.  
11.Adjust the time needed by tapping the UP button.  
12.Press ENTER to save the settings for the scene you are editing, the display will  
change to the next scene automatically.  
13.Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes  
maximum.  
14.Press MODE/ESC to exit and save your edited scene into the fixtures internal  
©Elation Professional, Los Angeles Ca.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
memory. The number of steps can be defined under “EDIT” and the scenes can  
be called up under “Run.” To run the scenes see page 30.  
Editing procedure 2: Using an external controller.  
1. Call up the first scene in your controller now.  
2. Select “SC01” by pressing the UP or DOWN buttons.  
3. Press MODE/ESC, the display shows “SC01”.  
4. Press MODE/ESC, the display shows “C-01”.  
5. Select "CEDT" by pressing the UP or DOWN buttons.  
6. Press MODE/ESC, the display shows "OFF".  
7. Press UP, the display will read "ON".  
8. Press MODE/ESC, the display shows "SC02". You successfully downloaded  
the first scene.  
9. Adjust the Step-time as described above.  
10. Call up the second scene in your controller now.  
11. Repeat steps 5-11 until all desired scenes are downloaded.  
12. Press MODE/ESC to exit. The number of steps can be defined under “STEP”  
and the scenes can be called up under “RUN.”  
RUN  
- This function allows you to “RUN” the user-installed program. You can set the  
number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “RUN” is displayed, press ENTER.  
4. The display will show “ON/OFF”.  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press MODE/ESC to return to the main menu.  
©Elation Professional, Los Angeles Ca.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
9. DMX ADDRESSING  
Setting the DMX address - After the fixture is turned “ON” it will immediately complete a  
reset process that test all the fixture’s functions. When the reset process concludes the LCD  
will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the  
display will flash continuously. To set or adjust a DMX address, please follow the procedure  
below:  
1. Toggle through the menu by pressing the Up and Down buttons until the display  
reads “Addr=XXX.” Tap the enter button to make changes to the address.  
2. While the display is flashing use the “UP” and “DOWN” buttons to select a new  
address. Once the new address has been selected, lock the new address into  
the fixture’s memory by pressing the “ENTER” button.  
The DMX address is non-volatile and will remain in the fixture’s memory even when the  
power to the unit is switched off. Memory is backed-up and retain by an internal power  
source that should last about five years  
Remote DMX addressing (RDMX) / Address Via DMX- This function allows the DMX  
address to be changed remotely from a DMX console. This setting requires special settings  
for both the controller and the fixture. This function may be turned on and off, and is “ON” be  
default. Follow the procedure listed below to access the RDMX functions:  
Fixture Settings:  
8. Access the main menu and use the UP or DOWN to get to the  
“Personality” menu, then press ENTER  
9. Once in the “Personalities” menu, tap the UP or Down to get to the  
“Status Settings “ menu, press ENTER.  
10.Once in the “Status Settings” tap the UP or Down to get to the “Address via  
DMX” function and press ENTER.  
11.Address via DMX” is the function that turns the RDMX function on and off.  
Press ENTER and be sure the function is turned on.  
12.Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
©Elation Professional, Los Angeles Ca.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
13.Press ENTER to confirm.  
14.Press MODE/ESC to return to the main menu.  
Controller Settings:  
6. Set the DMX value of channel 1 to a value of 7.  
7. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is  
set to "7" you can adjust the starting address between 1 and 255. When  
set to "8" you can adjust the starting address between 256 and 511.  
8. Use channel 3 to set your desired DMX starting address. For example: If  
you want to set the starting address to 57, set channel 1 to a value of “7,”  
set channel 2 to a value of “7” and use channel 3 to set your address to  
57 by selecting a channel value of 57. Example 2: If you want to set the  
starting address to 420, set channel 1 to a value of “7,” channel 2 to "8"  
and channel 3 to "164" (256+164=420).  
9. Wait for approximately 20 seconds for the unit to complete the  
address reset function.  
©Elation Professional, Los Angeles Ca.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
10. DMX CHANNEL TRAITS:  
The chart below details the channel layout for 14 DMX channels (default).  
In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the fixture  
into a 12-channel DMX fixture.  
CHANNEL 1: Pan Movement (max. 540° or 630˚ User Selectable)  
CHANNEL 2: 16bit Pan Movement (pan fine)  
CHANNEL 3: Tilt Movement (max. 265°)  
CHANNEL 4: 16bit Tilt Movement (tilt fine)  
CHANNEL 5: Color Wheel  
CHANNEL 6: Gobos rotating  
CHANNEL 7: Rotating gobo  
CHANNEL 8: Prism rotating  
CHANNEL 9: Rotating prism  
CHANNEL 10: Focus  
CHANNEL 11: Strobe (0-13Hz), Shutter close/open function + random strobe  
CHANNEL 12: Dimmer (Intensity) Control  
CHANNEL 13: Speed Control (Pan/Tilt movement, blackout selection)  
CHANNEL 14: Special (program control + lamp on, motor reset, lamp switch off)  
©Elation Professional, Los Angeles Ca.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
DMX channel function and values:  
DMX channel functions and their values (14 DMX channels):  
Mode/Channel  
Value  
Function  
St  
Ba  
Ex  
PAN Movement 8bit  
Pan Movement By 540/630  
Pan Fine 16bit  
Fine control of Pan movement  
TILT Movement 8bit  
Tilt Movement By 270  
Tilt Fine 16bit  
Fine control of Tilt movement  
Color Wheel  
1
2
3
4
1
0-255  
0-255  
0-255  
0-255  
2
0-14  
15-29  
Open / white  
Color1  
30-44  
Color2  
45-59  
Color3  
60-74  
Color4  
5
3
75-89  
Color5  
90-104  
105-119  
120-127  
128-189  
190-193  
194-255  
Color6  
Color7  
Color8  
Forwards rainbow effect from fast to slow  
No rotation  
Backwards rainbow effect from slow to fast  
Rotating gobos, cont. rotation  
Open  
6
4
0-9  
10-19  
Rotating gobo 1  
20-29  
Rotating gobo 2  
30-39  
Rotating gobo 3  
40-49  
Rotating gobo 4  
50-59  
Rotating gobo 5  
60-69  
Rotating gobo 6  
70-79  
Rotating gobo 7  
80-95  
Rotating gobo 1 shake  
Rotating gobo 2 shake  
Rotating gobo 3 shake  
Rotating gobo 4 shake  
Rotating gobo 5 shake  
96-111  
112-127  
128-143  
144-159  
©Elation Professional, Los Angeles Ca.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
160-175  
176-191  
192-255  
Rotating gobo 6 shake  
Rotating gobo 7 shake  
Rotating gobo wheel cont. rotation slow to fast  
Rotating gobo index, rotating gobo rotation  
Gobo indexing  
0-127  
7
5
128-189  
190-193  
194-255  
Forwards gobo rotation from fast to slow  
No rotation  
Backwards gobo rotation from slow to fast  
Rotating prism, Prism / Gobo macros:  
0-31  
32-63  
Open  
3 facet prism  
Infinite (Trapezoid) prism  
5 facet prism  
Macro 1  
64-95  
96-127  
128-135  
136-143  
144-151  
152-159  
160-167  
168-175  
176-183  
184-191  
192-199  
200-207  
208-215  
216-223  
224-231  
232-239  
240-247  
248-255  
Macro 2  
Macro 3  
Macro 4  
Macro 5  
Macro 6  
8
6
Macro 7  
Macro 8  
Macro 9  
Macro 10  
Macro 11  
Macro 12  
Macro 13  
Macro 14  
Macro 15  
Macro 16  
Rotating prism index, rotating prism rotation:  
Prism indexing  
0-127  
128-189  
190-193  
194-255  
Forwards prism rotation from fast to slow  
No rotation  
Backwards prism rotation from slow to fast  
Focus:  
Continuous adjustment from far to near  
Shutter, strobe  
9
7
10  
11  
8
9
0-255  
0-31  
Shutter closed  
©Elation Professional, Los Angeles Ca.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
32-63  
64-95  
No function (shutter open)  
Strobe effect slow to fast  
No function (shutter open)  
Pulse-effect in sequences  
No function (shutter open)  
Random strobe effect slow to fast  
No function (shutter open)  
Dimmer (intensity)  
Intensity 0 to 100%  
96-127  
128-159  
160-191  
192-223  
224-255  
12  
13  
10  
11  
0-255  
Speed pan/tilt movement  
Max to min speed  
Movements trigger blackout  
Wheel changes trigger blackout  
No function  
0-225  
226-235  
236-245  
246-255  
Reset, internal programs  
Color change normal  
Color change to any position  
No function  
0-19  
20-39  
40-59  
60-79  
No function  
80-84  
All motors reset  
85-87  
Scan motors reset  
88-90  
91-93  
Colors motors reset  
Gobo motors reset  
14  
12  
94-96  
No function  
97-99  
Other motor reset  
100-119  
120-139  
140-159  
160-179  
180-199  
200-219  
220-239  
240-255  
Internal program 1  
Internal program 2  
Internal program 3  
Internal program 4  
Internal program 5  
Internal program 6  
Internal program 7  
Auto program by music  
©Elation Professional, Los Angeles Ca.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
11.ERROR CODES:  
When power is applied, the unit will automatically enter a “reset/test” mode. This mode  
brings all the internal motors to a home position. If there is an internal problem with one or  
more of the motors an error code will flash in the display in the form of “XXer” were as XX will  
represent a function number. For example, when the display shows “0Er,” it means there is  
some type of error with the Pan motor. If there are multiple errors during the start-up process  
they will all flash in the display. For example: if the fixtures has errors on channel 1, channel  
2, and channel 5 all at the same time, you will see the error message “01Er”, “02Er,”  
and ”05Er” flash repeated 5 times.  
If an error does occur during the initial start-up procedure the fixture will self-generate a  
second reset signal and try to realign all the motors and correct the errors, if the error persist  
after a second attempt a third attempt will be made.  
If after a third attempt all the errors have not been corrected the fixture will make the  
following determinations: 1) 3 or more errors - The fixture cannot function properly with three  
or more errors therefore the fixture will place itself in a stand-by mode until subsequent  
repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors, therefore  
most other functions will work properly. The fixture will attempt to operate normally until the  
errors can be correct by a technician. The errors in question will remain flashing in the  
display as a reminder of internal errors.  
PAN Error: The yoke is not located in the default position after start-up or after a reset  
command. This message will appear after a fixture reset if the pan’s magnetic-indexing  
circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective  
motor or a defective motor IC drive on the main PCB). This error may also be displayed if the  
head/yoke was blocked during a reset function.  
TILT Error: This message will appear after a fixture reset if the tilt’s magnetic-indexing  
circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective  
motor or a defective motor IC drive on the main PCB). This error may also be displayed if the  
head was blocked during a reset function.  
©Elation Professional, Los Angeles Ca.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
Color-wheel error:  
The color wheel is not located in the default position after start-up or after a reset command.  
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit  
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure  
(defective motor or a defective motor IC drive on the main PCB).  
Rotating gobo-wheel error:  
The gobo-wheel is not located in the default position after start-up or after a reset command.  
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit  
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure  
(defective motor or a defective motor IC drive on the main PCB).  
Rotating gobo indexing error:  
The gobo is not located in the default position after start-up or after a reset command. This  
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit  
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure  
(defective motor or a defective motor IC drive on the main PCB).  
Prism-wheel error  
This message will appear after the reset of the fixture and if the magnetic-indexing circuit  
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its  
driver circuit on the main PCB). The Prism wheel is not located in the default position after  
the reset.  
Focus-error  
This message will appear after the reset of the fixture and if the magnetic indexing circuit  
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its  
driver circuit on the main PCB). The focus motor is not located in the default position after  
the reset.  
©Elation Professional, Los Angeles Ca.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
12. CLEANING AND MAINTENANCE  
The following points have to be considered during the inspection:  
1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may  
fall out during normal operation resulting in damage or injury as larger parts could fall.  
2. There must not be any deformations on the housing, lenses, rigging hardware and  
rigging points (ceiling, suspension, trussing). Damaged rigging points or unsecured  
rigging could cause the unit to fall and serious injure a person.  
3. All mechanical parts and motors should not show any traces of serious wear and  
should rotate freely.  
4. Electric power supply cables must not show any damage, material fatigue or  
sediments. Never remove the ground prong from the power cable.  
Further instructions depending on installation and usage have to be adhered by a skilled  
installer and any safety problems should be addressed before attempting operation.  
We recommend frequent cleaning of the fixture to ensure operational longevity and crisp  
light output. When cleaning, please use a moist, lint-free cloth. Never use alcohol or  
solvents.  
There are no user serviceable parts inside this fixture with the exception of the lamp. Please  
refer all other service related issues to an authorized Elation service technician.  
Should you decide to service the fixture yourself please order genuine Elation parts directly  
from Elation.  
©Elation Professional, Los Angeles Ca.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
13. Photometric Data:  
©Elation Professional, Los Angeles Ca.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
17. GOBOS:  
©Elation Professional, Los Angeles Ca.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
15. DIMENSIONAL DRAWINGS:  
©Elation Professional, Los Angeles Ca.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
16. CIRCUIT SCHEMATICS  
©Elation Professional, Los Angeles Ca.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
17. TECHNICAL SPECIFICATIONS  
Power supply  
100~240v 50/60Hz  
Internal Voltage Taps  
Power Requirements  
Fuse protection  
120V = 3.15A/250V, GMA (5x20mm fine-wire fuse)  
220V = 2A/250V, GMA (5x20mm fine-wire fuse)  
180w (maximum @ at full power)  
Power Consumption  
Light Source  
LED  
CTB-90-W  
Life Time  
60,000 Hours (Rated)  
Optical  
Parabolic glass reflector  
15° standard objective  
Lens anti-reflex  
Color Mixing  
8 dichroic filters plus white, half-color compatible  
Gobos  
Gobo-wheel: 4 interchangeable rotating gobos plus "open", 3 glass Gobo  
Gobo outside diameter 26.9 mm, image size 24 mm  
Gobo thickness: glass = 1 mm, steel = 0.4 mm  
Shutter / Strobe / Dimmer  
Strobe-effect with variable speed 0 - 13 flashes per second  
Continuously dimming 0% - 100%  
Prism  
Rotating 3-face prism, rotating and variable in speed  
Focus  
Motor driven focus from near to far away  
DMX Channels  
14 (16bit – default)  
DMX Drive  
Standard DMX-512, 3 pole & 5 pole XLR; [+] = Pin 3  
Starting DMX [001].  
[-] = Pin 2  
[Ground] = Pin 1.  
Pan / Tilt  
Pan- movement  
Tilt- movement  
Weights and measures  
Dimensions  
630° in max. 2.0 seconds, 16 bit resolution  
270° in max. 1.5 seconds, 16 bit resolution  
11.42” (H) x 9.57” (W) x 16.02” (D) ~ Head vertical  
23 Lbs  
Weight (net)  
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change  
without any prior written notice.  
©Elation Professional, Los Angeles Ca.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
©Elation Professional, Los Angeles Ca.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E SPOT LED™  
©Elation Professional, Los Angeles Ca.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Elation Professional®  
6122 S. Eastern Ave.  
Los Angeles, CA. 90040  
323-582-3322 / 323-832-9142 fax  
Version 1.0  
Rev. 27/10/2009 – visage  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edimax Technology Network Router AC M1000 User Manual
Elation Professional Work Light 60TM User Manual
Electro Voice Microphone 1777 User Manual
Escient Portable Multimedia Player MP 200 User Manual
Fisher Price Motorized Toy Car K3115 User Manual
Fundex Games Games Old Maid User Manual
GE Clothes Dryer DCCD330EDKC User Manual
GE Clothes Dryer PSXH43 User Manual
GE Hot Beverage Maker 168950 User Manual
GE Monogram Refrigerator ZISS360DMSS User Manual