ZVB36SN/BN
GE Monogram® 36" Telescopic Downdraft Vents
Dimensions and Installation Information (in inches)
Separate Raise/
Lower Switch
All 36" models are equipped with a separate raise/lower
switch. The switch must be installed in a separate location
outside of the vent and cooktop cutout.
Countertop Requirements
Countertops must have a deep flat surface to accommodate
the cooktop and the vent. Countertops with a rolled edge and
backsplash may not provide the flat surface area required.
Base Cabinet Requirements
The base cabinet must be deep enough to accommodate the
minimum clearance to the front edge of the countertop, the
cooktop burner box and the vent.
Downdraft Vent and Cooktop Cutout
The installation of these downdraft vents with any Monogram
cooktop requires careful consideration. For accurate planning,
review the individual dimension drawings for the combined vent
and Monogram cooktop installation.
Before you begin you must:
1. Review countertop dimension illustrations to be sure you will
have enough flat countertop surface depth.
2. Check to be sure that the total countertop depth required
(including minimum cutout to front edge depth) allows enough
space for a backsplash.
3. Review the cabinet illustration. Check to be sure that the
interior cabinet depth will house the cooktop burner box, the
vent and the cutout clearance from the front.
4. When countertop and cabinet depth present a problem, review
Creative Solutions.
5. Carefully review the installation instructions packed with
With careful planning you can achieve a custom look with
minimal adjustments.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Listed by
Underwriters
Laboratories
Specification Created 11/08
130676
Download from Www.Somanuals.com. All Manuals Search And Download.
ZVB36SN/BN
GE Monogram® 36" Telescopic Downdraft Vents
Dimensions and Installation Information (in inches)
Venting Options
The downdraft vent is shipped with the discharge outlet
pointing straight down and can be changed to a left- or
right-side discharge. For even more flexibility, the entire
blower and mounting plate can be adjusted 3-1/2" to the
left or right sides.
Electrical and Gas Locations
Plan the placement of the electrical outlet and gas (if used)
carefully. Gas or electrical outlets cannot be located on the
back wall of the cabinet because they may interfere with the
downdraft plenum.
• Install a standard electrical outlet within reach of the
vent’s two-foot-long power cord. Locate the outlet inside
the cabinet on the right side wall.
• If the vent is installed in combination with a Monogram®
gas cooktop, it may operate from the same 120V standard
duplex outlet.
• If the vent is installed in combination with a Monogram
electric cooktop, the vent must operate from a separate
120V outlet.
Do Not Locate Gas or Electrical
Connections Within Shaded Area
29-1/2"
Electrical
Outlet
12" Above
Cabinet Floor
34" for 36" Models
28-1/2" for 30" Models
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Listed by
Underwriters
Laboratories
Specification Created 11/08
130676
Download from Www.Somanuals.com. All Manuals Search And Download.
ZVB36SN/BN
GE Monogram® 36" Telescopic Downdraft Vents
Features and Benefits
• Raises To 8-1/2” Over Cooktop Surface When
You Cook, Then Retracts When Not in Use
• 500-CFM Performance Helps Keep Your Kitchen
Free of Fumes and Excess Heat
• Remote-Mounted Control Provides
Design Flexibility
• Variable-Speed Blower with Electronic Controls
Complements Most Monogram Cooktops
• Removable Grease Filters Trap Airborne
Grease Particles
• Optional Remote Blower Capabilities
• Stainless Steel Vent Body Offers a Smooth and
Polished Appearance
• Model ZVB36SNSS - Stainless steel (shown)
• Model ZVB36BNBB - Black on black
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Created 11/08
130676
Download from Www.Somanuals.com. All Manuals Search And Download.
|