Safety Instructions . . . . . . . . . 2, 3
Owner’s Manual and
Installation Instructions
Operating Instructions
Light Controls . . . . . . . . . . . . . . . .4
Vent Controls . . . . . . . . . . . . . . . .4
JV936
CV936
Care and Cleaning
Grease Filters . . . . . . . . . . . . . . . .5
Hood Lights . . . . . . . . . . . . . . . . .6
Hood Surfaces . . . . . . . . . . . . . . . .5
Stainless Steel Surfaces . . . . . . . . .5
Installation Instructions . . .7–18
Troubleshooting Tips . . . . . . . .20
Consumer Support
Consumer Support . . . Back Cover
Product Registration . . . . . .21, 22
Warranty . . . . . . . . . . . . . . . . . . . 23
Write the model and serial
numbers here:
Model # ________________
Serial # ________________
You can find them on a label
on the inside of the hood.
350A4502P550 08-07 ATS
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
SAFETY PRECAUTIONS
WARNING –
TO REDUCE THE RISK OF
WARNING –
TO REDUCE THE RISK OF FIRE,
A RANGE TOP GREASE FIRE:
USE ONLY METAL DUCTWORK.
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
■Do not attempt to repair or replace any
part of your hood unless it is specifically
recommended in this guide. All other servicing
should be referred to a qualified technician.
OpeagIructions
B. Always turn hood ON when cooking at high
heat or when cooking flaming foods.
C. Clean ventilating fans frequently. Grease
should not be allowed to accumulate on fan
or filter.
D. Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING –
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
rdCleaing
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction.
B. Sufficient air is needed for proper
combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and
safety standards such as those published by
the National Fire Protection Association
(NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
T
r
ubleshotingT
C. When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
D. Ducted fans must always be vented to the
outdoors.
ips
CnsmeSuport
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
READ AND SAVE THESE INSTRUCTIONS
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the hood controls.
Throughout this manual, features and appearance may vary from your model.
SafeyIructions
FAN Control
Turn the FAN speed control to LO, MED LO,
MED HI or HI, as needed.
LIGHT Control
Turn the LIGHT control to HI for bright light
while cooking. Turn to NITE for use as a night
light.
s
Continuous use of the fan system while cooking
helps keep the kitchen comfortable and less
humid. It also reduces cooking odors and soiling
moisture that create a frequent need for
cleaning.
NOTE: When the fan is operating on the LO setting,
it will be very quiet. Always make sure that the fan
is turned OFF when you are finished in the kitchen.
rdCleaing
ips
rubleshotingT
T
CnsmeSuport
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
Care and cleaning of the vent hood.
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the
vent hood.
Reusable Metal Grease Filters
The hood has 2 metal reusable
grease filters.
To remove:
Grasp the filter handle and pull it
up, forward and out.
The metal filters trap grease
released by foods on the cooktop.
They also help prevent flaming
foods on the cooktop from
To replace:
OpeagIructions
Hold the filter at the bottom
with the handle.
damaging the inside of the hood.
Place the top end of the filter
against the inside front of the
hood.
For this reason, the filters must
ALWAYS be in place when the
hood is used. The grease filters
should be cleaned once a month,
or as needed.
Slide it up until it stops and
push the bottom end back
until it snaps into place.
If it ever becomes necessary to
replace the metal grease filters, they
may be ordered from your GE supplier.
To clean the grease filters, soak
them and then swish them around
in hot water and detergent.
Don’t use ammonia or ammonia
products because they will darken
the metal. Do not use abrasives or
oven cleaners. Light brushing can
be used to remove embedded dirt.
Rinse, shake and let them dry
before replacing. They may
Heavy-duty commercial filters may
also be used in place of the filters.
For 30” (76.2 cm) hoods,
order Kit no. JXBF30SS.
rdCleaing
For 36” (91.4 cm) hoods,
order Kit no. JXBF36SS.
To order, call 1.800.661.1616
also be cleaned in an automatic
dishwasher.
Painted Surfaces (on some models)
To clean the hood surface, use
a hot, damp cloth with a mild
detergent suitable for painted
surfaces. Use a clean, hot, damp
cloth to remove soap. Dry with
a dry, clean cloth.
Do not use steel-wool pads or
other abrasive cleaners. They will
scratch the surface.
T
r
ubleshotingT
Stainless Steel Surfaces (on some models)
To order:
ips
To order CERAMA BRYTE® Stainless Steel
Cleaning Polish and Conditioner, please call
our toll-free number:
Do not use a steel-wool pad; it will
scratch the surface.
Clean a small area
(approximately 8” x 8” or
20.3 x 20.3 cm), rubbing with
the grain of the stainless steel if
applicable.
Shake bottle well.
National Parts
Place a small amount of
CERAMA BRYTE® Stainless
Steel Cleaning Polish and
Conditioner on a dry cloth
or dry paper towel.
CnsmeSuport
Center . . . . . . . . . . . 1.800.661.1616
Dry and buff with a clean, dry
paper towel or soft cloth.
CERAMA BRYTE®
Stainless Steel Cleaning
Repeat as necessary.
Polish and Conditioner . . . # PM10X313
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and cleaning of the vent hood.
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of
the vent hood.
Receptacle
Hood Lights
Socket
NOTE: The glass cover should be removed
only when cold. Wearing latex gloves may
Receptacle
SafeyIructions
offer a better grip.
CAUTION: Before replacing your
to the hood at the main fuse or circuit
breaker panel.
light bulb, disconnect the electrical power
Bulb
Use gloves
or cloth
Be sure to let the light cover and bulb cool
Glass cover
completely.
Push the bulb straight into the
receptacle all the way.
For your safety, do not touch a hot bulb
with bare hands or a damp cloth.
Place the glass cover onto the socket
and turn clockwise until secure.
To remove:
Turn the glass cover counterclockwise
until the glass cover clears the socket.
OpeagIructions
For improved lighting, clean the glass
cover frequently using a damp cloth.
This should be done when the hood
is completely cool.
Using gloves or a dry cloth, remove
the bulb by pulling it straight out.
To replace:
Reconnect electrical power to
the hood.
Use a new 12-volt, 20-watt (maximum)
Halogen bulb for a G-4 base.
Using gloves or a dry cloth, remove
the new bulb from its packaging.
NOTE: Do not touch the new halogen bulb
with bare fingers. Touching the bulb with
bare fingers will significantly reduce the
life of the bulb.
rdCleaing
ips
rubleshotingT
T
CnsmeSuport
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Instructions
Range Hood
Questions? Call 1-800-561-3344 or Visit our Website at: www.GEAppliances.ca
PRODUCT DIMENSIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
12"
•
IMPORTANT –
Save these
instructions for local inspector’s use.
•
IMPORTANT –
Observe all
governing codes and ordinances.
18"
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions
for future reference.
• Skill level – Installation of this vent hood requires
29-7/8"
21"
basic mechanical and electrical skills.
30” Models
Requires a 30” Wide Opening
• Completion time – 1 to 3 hours
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
12"
CAUTION:
18"
Due to the weight and size of these vent hoods and to
reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
21"
35-7/8"
36” Models
FOR YOUR SAFETY:
Requires a 36” Wide Opening
WARNING –
Before beginning the
installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
1 Ft = 0.3 m
1” = 2.5 cm
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
INSTALLATION CLEARANCES
OPTIONAL ACCESSORIES
Duct Cover
A Decorative duct cover is available to accommodate 8
to 10 ft. ceiling heights. The duct cover will expand
from 12” Min. or 24” to 34” Max. height.
These vent hoods are designed to be installed onto a
wall. They may be installed beneath a soffit or cabinet.
• Install these hoods 24” Min. to 36” Max above the
cooking surface.
• The duct cover conceals the ductwork running from
the top of the hood to the ceiling.
• The duct cover accessory fits both 30” and 36” wide
models. Order the duct cover accessory at the same
time as the vent hood. All accessories should be on
site at the time of hood installation.
SOFFIT INSTALLATION
SOFFIT
Order the correct color to match your model:
JXCHBB - Black, JXCHWW - White,
JXCHCC - Bisque, JXCHSS - Stainless Steel.
24" MIN.
36" MAX.
Ceiling Bracket
In this installation the ductwork running from the top
of the hood will be concealed in the soffit or upper
cabinetry.
WALL MOUNT INSTALLATION
2 Wood 2 Washers
Screws
2 Wall
Fasteners
2-Piece Duct Cover
With Ceiling Bracket
4 Phillips Head
Screws
24" MIN.
36" MAX.
2 Phillips Head
Decorative Screws
For this installation, a decorative duct cover is available
to conceal the ductwork running from the top of the
hood. Use of the duct cover requires special
consideration to the installation height above the
countertop. See page 12 for details.
Commercial Filter Kit
Use this kit to replace supplied filters.
JXBF30SS, Commercial Filter Kit for 30” wide models.
JXBF36SS, Commercial Filter Kit for 36” wide models.
1 Ft = 0.3 m
1” = 2.5 cm
Includes 2 commercial filters and 2 drip trays.
2 Baffle Filters
2 Drip Trays
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
ADVANCE PLANNING
Ductwork Planning
• This hood may be vented vertically through upper
cabinets, soffit or ceiling. A duct transition piece is
supplied for vertical exhaust. Use locally supplied
elbows to vent horizontally through the rear wall.
See page 13.
DECORATIVE DUCT COVERS
A decorative duct cover is available to fit both model
widths. The duct cover conceals the ductwork running
from the top of the hood to the ceiling or soffit. The
duct cover will fit 8 ft. to 10 ft. ceiling heights. See page
12 for details.
• Determine the exact location of the vent hood.
• Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should not
exceed 100 equivalent length for any duct
configurations.
POWER SUPPLY
IMPORTANT - (Please read carefully)
• Refer to “Duct Fittings” chart to compute the
maximum permissible length for duct runs to the
outdoors.
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
• Use metal ductwork only.
• A transition piece for 7” round duct is supplied. Use 7”
round duct or you may use 3¼” x 12” rectangular.
• Install a wall cap or roof cap with damper at the
exterior opening. Order the wall or roof cap and any
transition needed in advance.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing
local codes and ordinances.
Kit - JXDW1
Order kit JXDW1 if your installation requires horizontal
ducting from the top of the hood through the back wall
and:
• You have an 8 ft. ceiling and need to use a JXCH
Series Chimney Cover, or
• You have a 12” cabinet or 12” soffit that the hood is to
be mounted beneath.
This kit provides a duct transition from 7” round to
3¼” x 10” rectangular for through-the-wall venting.
Electrical supply
This vent hood must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker
or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Wall Framing for Adequate Support
• Route house wiring as close to the installation location
as possible in the ceiling, soffit or wall. See page 13 for
details.
• Connect the wiring to the house wiring in accordance
with local codes.
• This vent hood is heavy. Adequate structural support
must be provided. The hood must be secured to
vertical studs in the wall. See page 14.
• We strongly recommend that the vent hood with duct
cover be on site before final framing and wall
finishing. This will also help to accurately locate the
ductwork and electrical service.
Grounding instructions
The grounding conductor must be connected to a
ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
DUCT FITTINGS
Follow these guidelines for proper duct sizing in the
ducting charts.
WARNING:
The improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative if
you are in doubt whether the appliance is properly
grounded.
DUCTING CHART - 30” and 36” Models
Equivalent Length in Feet for 7” Round Duct
0
25
75
100
125
150
50
600
500
400
300
200
1 Ft = 0.3 m
1” = 2.5 cm
7” Round 90° Elbow = 8 ft.
7” Roof Cap = 30 ft.
MAXIMUM DUCT LENGTH: 7” dia. duct, should not
exceed 100 equivalent feet.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Total
Equivalent
Length
DUCT FITTINGS
Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.
Equivalent
Length*
1 ft.
(per foot
length
Quantity
Used
Duct Piece Dimensions
Round,
straight
Note: Do not exceed maximum permissable
equivalent lengths!
1 ft.
(per foot
length
3¼” x 12”
straight
Maximum duct length:
100 foot for vent hoods.
90° elbow
45° elbow
8 ft.
6 ft.
Flexible ducting:
If flexible metal ducting is used, all
the equivalent feet values in the table
should be doubled. The flexible
metal duct should be straight and
smooth and extended as much as
possible.
3¼” x 12” or
90° elbow
15 ft.
9 ft.
Do NOT use flexible ducting.
3¼” x 12” or
45° elbow
Note: Any home ventilation system, such as a
ventilation hood, may interrupt the proper flow of
combustion air and exhaust required by fireplaces,
gas furnaces, gas water heaters and other
naturally vented systems. To minimize the chance
of interruption of such naturally vented systems,
follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by NFPA and ASHRAE.
3¼” x 12” or
90° flat elbow
20 ft.
1 ft.
7” round to
3¼” x 12”
transition
3¼” x 12” to 7” round
This Hood Must Use 7” Round
Duct. It Can Transition To
3¼” x 12” Duct
transition
5 ft.
7” round to
3¼” x 12”
transition 90° elbow
5 ft.
Kit - JXDW1
Order kit JXDW1 if your
installation requires horizontal
ducting from the top of the hood
through the backwall and:
• You have an 8 ft. ceiling and
need to use a JXCH Series
Chimney Cover, or
• You have a 12” cabinet or 12”
soffit that the hood is to be
mounted beneath.
This kit provides a duct transition
from 7” round to 3¼” x 10”
rectangular for through-the-wall
venting.
3¼” x 12” to7” round
transition 90° elbow
15 ft.
Round
wall cap
with damper
30 ft.
30 ft.
30 ft.
24 ft.
3¼” x 12”
wall cap with
damper
7” round
roof cap
Round
roof vent
Using a smaller diameter duct
size will reduce performance
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
1 Ft = 0.3 m
1” = 2.5 cm
Total Duct Run
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
REMOVE THE PACKAGING
• Remove parts package from the “V” shaped cardboard
insert. Remove insert. Remove shipping pads.
• Lift the hood out of the box.
CAUTION:
Lift hood by grasping the outside edges of the exhaust
opening on the top. Do not lift hood by the exhaust
opening divider – damage will occur.
Duct tape
Pencil and
tape measure
Phillips and
Flat blade screwdrivers
Parts
Package
Wood
Duct
Mounting
Support
Hood
Transition
Electric drill with
1/8” and 3/8” bits
¼” pivoting hex socket
Safety glasses
Motor
Mounted on
Skid
Spirit level
Flashlight
Shipping Carton
• Remove transition duct piece from the inside of the
hood. Discard screws.
• The vent hood motor is shipped secured to the skid
with 4 screws. Locate and remove 2 screws on each
side of the motor. Discard the shipping skid.
cUL Listed Wire nuts
Hold Down Screws
Pliers
Hammer
Metal snips
Wire Cutter/Stripper
Hold Down Screws
Saber saw or Key Hole Saw
Allen Wrench
• From the inside of the hood, remove shipping screws
holding the wood mounting piece to the back side of
the hood. Set aside wood mounting piece and screws
for later installation. Do not discard.
• Remove junction box cover and knockout.
• Install strain relief onto back or top of hood.
• Remove all tape and packing material from the hood,
duct transition and motor.
Ladder
Additional Materials:
• 120V 60Hz. 15 or 20 Amp, 2 wire with ground.
Properly grounded branch circuit.
1 Ft = 0.3 m
1” = 2.5 cm
• Strain relief for junction box.
• 7” round metal duct or 3¼” x 12” rectangular duct, length
to suit installation.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PARTS PROVIDED
Locate the hardware accessory box packed with the
hood and check contents.
Screws, wall
fasteners, washers
Filter Support
Duct Transition
with Damper
2 Aluminum
Grease Filters
2 Control Knobs
Review the following examples to ensure a trouble free
installation using the duct cover accessory.
DUCT COVER REQUIREMENTS
We recommend that the vent hood and decorative duct
cover (if used) be on site before final framing and wall
finishing. This will help to accurately locate studs,
ductwork and electrical service. Read these instructions
to determine if the duct cover accessory can be used for
your installation situation.
8 ft. Ceiling
8 ft. ceilings: The hood
12"
must be installed at 30”
above the cooking
surface (or 66” above the
floor). The duct cover
willnot fit if the hood is
installed at a lower or
higher height. Use the
Duct Cover Accessory:
30"
• Use the decorative duct
cover to conceal duct
work running from the
top of the hood to the
ceiling.
• The duct cover accessory
consists of 2 pieces. The
outside piece is 12” high,
outside 12” section,
discard the inside section.
9 ft. Ceiling
12"
24"
30"
the inside piece is 22”.
22"
Nested together they are
24” min., expanding to a
total maximum height of
34”.
12"
30"
24"
• The outside piece can be
used alone to fill a 12”
height.
• For heights over 12”, the
ceiling bracket must be
installed to secure the
cover at the top.
12"
9 ft. ceilings: Install the hood 24” min. and up to a maximum of 30”
above the cooking surface. The duct cover will expand to reach
ceiling height.
11"
10 ft. Ceiling
30"
34"
To avoid unsightly gaps, plan the hood installation
height for duct cover use.
• The cover will fit a 12” min. height from the top of the
hood to the ceiling,
– or 24” min. and expanding up to 34” from the top
of the hood to the ceiling.
THE DUCT COVER CANNOT BE USED WHEN THE
DISTANCE ABOVE THE TOP OF THE HOOD IS
BETWEEN 12” AND 24”.
36" Max.
32"
10 ft. ceilings: nstall the hood 32” min. to 36” max. above the
cooking surface. The duct cover will expand to a maximum of 34”
above the top of the hood to meet the ceiling.
1 Ft = 0.3 m
1” = 2.5 cm
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
• Measure desired distance from the bottom of the
FOR CEILING
VENT DUCTING
hood to the cooking surface, 24” min. to 36” max.
Refer to the previous page if the accessory duct cover
will be used.
6-7/8”
Centerline To Wall
• Use a level to draw a horizontal line indicating the
bottom of the hood.
Electrical
• Use a level to draw the cooktop centerline location.
• Measure 15-3/8” up from the horizontal line for the
bottom of the hood. Draw another horizontal line.
• Measure 18” up from the line for the bottom of the
hood, draw another horizontal line to indicate the top
of the hood.
7½” Dia. Hole
Centerline
8” Min. above
Top of Hood
FOR WALL VENT DUCT
Top of Hood
FOR VERTICAL (Straight Up) DUCTING:
• If venting out the ceiling, extend the centerline
forward on the ceiling.
– Measure 6-7/8” from drywall to mark centerline for a
7½” dia. duct hole on the ceiling.
– If drywall is not present, add drywall thickness to the
6-7/8” dimension.
Wood Support
18"
15-3/8"
Electrical
Bottom of Hood
Venting through a soffit or upper cabinet.
• Follow the same procedure for ceiling ducting to cut
the 7½” dia. hole through the top of the cabinet or
soffit.
• See Step 4, page 5 for details to cut opening for duct
transition.
FOR DUCTING THROUGH REAR WALL:
• Measure the supplied duct transition with any straight
run length of duct used, plus 90° elbow height. Draw a
horizontal line on the wall intersecting the centerline.
House Wiring Location:
14-1/8” for 36” Models
11-1/8” for 30” Models
• The junction box is fastened to the back of the hood
on the right side. See illustrations for hood knockout
locations.
5-7/8"
Note: The junction box can be relocated to the inside
top of the hood.
House wiring may enter the junction box from the rear
or the top of the hood at the right side.
To route house wiring through the ceiling or soffit;
– Cut a hole approximately 1” dia., 5-7/8” forward on
the ceiling, 11-1/8” to the right of the centerline for
30” models or, 14-1/8” to the right of the centerline
for 36” models.
Knockout
Locations
To route house wiring through the wall,
– Cut a hole approximately 1” dia., 10-1/16” down from
the top of the hood, 11-1/8” to the right of the
centerline for 30” models or, 14-1/8” to the right of
the centerline for 36” models.
10-1/16"
• Remove top or rear knockout depending on your
installation.
14-1/8” for 36” Models
11-1/8” for 30” Models
1 Ft = 0.3 m
1” = 2.5 cm
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
INSTALL HOOD SUPPORT
INSTALL TRANSITION
1
2
Remove
Shipping
Tape on
Damper
IMPORTANT:Remove
shipping tape from
damper and check that
damper moves freely.
IMPORTANT: Framing must be capable of
supporting 100 lbs (45.3 kg)
• Locate at least 2 vertical studs at the wood mounting
location by tapping drywall with a hammer or use a
stud finder.
• Center the supplied wood horizontal support, left to
right and below the marked line.
Top of
Hood
Duct
Transition
7” Min. Opening for Ductwork
• Place the transition piece over the hood exhaust.
Secure transition to hood with 4 screws provided.
• Use duct tape to seal the connection.
INSTALL HOOD ONTO WALL
3
Wood
Support
• Lift the hood and place over the wood support. The
top keyhole slots in the hood should engage the
protruding mounting screws. Allow the hood to slide
down into position.
15-3/8"
24"
to
36"
• Pull house wiring through knockout at the rear or the
top of the hood.
• Check to be sure the hood is level and centered. The
arrow shaped cutout in the back of the hood allows
viewing the marked centerline.
Centerline of
Installation
space
• Remove cover from junction box.
• Drill 1/8” pilot holes through the support, drywall
and into the studs. Secure the support to 2 or
morevertical studs with supplied wood screws.
IMPORTANT: Screws must penetrate at least 1½” into
vertical studs. Countersink screws into support.
Cutout
24"
to
36"
Centerline of
Installation
space
Drill Bottom Mounting Hole Locations
• Drill 1/8” pilot holes into the two lower mounting
holes. Enlarge the holes if they did not enter studs to
3/8”.Tap anchors for wall fasteners into bottom holes.
– Install screws by hand into the fasteners to allow
anchors to expand against the wall. Remove screws.
• Using two large flat washers (supplied), install wood
screws or wall fastener screws, loosely, into lower
mounting holes. Do not tighten.
13-1/16"
¼”
Gap
• Check hood level. Tighten upper screws. Tighten
lower mounting screws.
• For additional security, drive screws through the
original wood support screw holes in the back of the
hood.
• Install mounting screws in the center of the wood
support, 13-1/16” from the centerline. The screws
should protrude forward ¼”. This ¼” gap will provide
clearance to hang the hood.
1 Ft = 0.3 m; 1” = 2.5 cm
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
IMPORTANT: For additional support and to minimize
Alternate Mounting Method
INSTALL HOOD TO SOFFIT OR
BENEATH CABINETS
4
vibration during operation, we strongly recommend that
the hood also be secured to the back wall with wall
fasteners.
30” Models
SKIP THIS STEP IF USING WALL MOUNTING
METHOD
2-9/16"
7-1/16"
2-1/4"
14-1/2"
14-1/2"
2-3/8"
IMPORTANT: Framing must be capable of
supporting 100 lbs (45.3 kg)
10-3/4"
12"
When necessary, the hood may be installed so that it is
supported by the soffit.
• The soffit should be constructed with 2 x 4’s.
• Determine the installation location.
• Continue the centerline forward on the bottom of the
cabinet or soffit.
8-7/16"
C
29-7/8"
Top View, Front Side
36” Models
2-9/16"
7-1/16"
2-1/4"
17-1/2"
17-1/2"
2-3/8"
10-3/4"
12"
8-7/16"
C
B
35-7/8"
A
A
Top View, Front Side
• Drill four 1/8” pilot holes in locations shown.
– If mounting to the underside of a cabinet with a
recessed bottom, install shims to fill the gap.
“A”
“B”
Centerline to
Center of Stud
Opening
For Ductwork
Cabinet or
30” Models
36” Models
14½”
17½”
10¾”W x 8-7/16”D
10¾”W x 8-7/16”D
Soffit
Transition
• Mounting screws must be secured to 2 x 4 studs
(Dim. “A”) at locations shown in the above chart.
• Allow minimum opening (Dim. “B”) to accommodate
the duct transition in the soffit.
Add Shims
If Bottom Is
¼” Gap
Recessed
Rear Wall
Engage Keyhole
Slots and Push
Back to Wall
Back Wall
2-3/8"
5-3/8"
5-3/8"
8-7/16"
• Drive mounting screws into the studs until they
protrude ¼”. This ¼” gap will provide clearance to
engage the keyhole slots in the top of the hood.
• Lift hood onto mounting screws. Slide back against
the rear wall.
C
Top View, Front Side
• Pull house wiring through the knockout at the rear or
the top of the hood.
• Tighten mounting screws.
Cut a 10¾” x 8-7/16” hole through bottom of soffit or cabinet
for duct transition as shown.
1 Ft = 0.3 m
1” = 2.5 cm
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CONNECT DUCTWORK
INSTALL CEILING BRACKET
6
5
• Push duct over the end of the transition until it
reaches the stop tabs.
• Install ductwork, making connections in direction of
airflow as illustrated.
The ceiling bracket must be installed when the duct
cover is used to span 24” or more height above the
hood. The bracket will hold the decorative duct cover in
place at the top.
• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints with duct tape for an airtight seal.
• Use duct tape to seal the flange connection.
Note: The ceiling bracket is not required when using
only the 12” section of the duct cover.
• Install the 2 small screws into the sides of the duct
bracket. Remove the screws. Pre-tapping the holes will
insure ease of final installation.
• Match center notch on the bracket to the centerline
on the wall and flush against the ceiling.
• Mark the 2 screw hole locations.
• Drill 1/8” pilot holes in marked bracket location.
• If pilot holes do not enter studs, enlarge the holes to
3/8” and install wall fastener anchors.
Air Flow
Duct Tape
Over Seam
Screw
and Screw
• Secure the bracket to the rear wall with wood screws
and washers. Use wall anchors if needed.
Duct
Stops
Duct Tape
Note: Bracket has 2 sets of holes. Use larger holes for wall
fasteners or wood screws with washers. Use smaller holes
for wood screws with washers.
Duct Tape
Over Flange
CAUTION:
Install Ceiling
Bracket When
Duct Cover is
Used to Span
24” or more
Do not use sheet metal screws at the hood flange
connection. Doing so will prevent proper damper
operations. Seal connection with tape only.
See Step 9
to Install
Duct Cover
1 Ft = 0.3 m
1” = 2.5 cm
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
INSTALL DUCT COVERS
INSTALL MOTOR
9
7
To install the 12” duct cover alone:
• Place the 12” section of the decorative duct cover on
top of the hood.
• Secure the cover to the top of the hood with 4 screws
provided.
• Align and engage the
slots in the blower
assembly to the 3 hooks
at the rear of the
Motor Attachment Bracket
exhaust opening.
• Rotate motor upwards
until it aligns with the
attachment screw
location.
• Secure the motor to
attachment bracket at
the front of the
To install the 12” duct cover alone:
Motor Hooks
• Place the 2-piece duct cover on top of the hood.
• Secure the bottom cover to the top of the hood with
4 screws provided. See illustration, page 16.
• Extend the inside section upwards to meet the ceiling
and ceiling bracket.
• Secure the duct cover to the bracket with the 2 small
Phillips screws provided.
opening with washer
and screw provided.
• Plug the motor connector into
the mating hood connector.
See the illustration for the
hood connector location.
Touch the hood to locate and
make the connection.
INSTALL FILTER SUPPORT
10
• Tip filter support into the rear of the hood.
• Insert support tabs into the slots at the rear of the
hood.
IMPORTANT: Hold the connector so
the two square corner terminals
are at the top as you position
the connector to plug it in.
Insert Tabs into Slots
CONNECT ELECTRICAL
8
Verify that power is turned off at the source.
WARNING:
If house wiring is not 2-wire with a ground wire, a
ground must be provided by the installer. When house
wiring is aluminum, be sure to use cUL. approved anti-
oxidant compound and aluminum-to-copper
connectors.
Insert 2 Screws
Remove
Junction Box
Cover
A
Insert Power
C
Coduit Thru
Strain Relief
and Tighten
White
Black
Ground
Check That White, Black and
Green Hood Wires Are Threaded
Thru Small Hole in Bracket
B
• Secure the support to the hood with screws as shown.
Use cUL Listed Wire Nuts
D
1 Ft = 0.3 m
1” = 2.5 cm
• Use wire nuts to connect incoming ground to green,
white to white and black to black.
• Push wires into junction box and replace cover. Be
sure wires are not pinched.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
INSTALL OPTIONAL COMMERCIAL
FILTERS
INSTALL FILTERS
11A
11
• Remove protective film covering the filters.
• Insert the filter into the “C” clips mounted to the top
of the vertical front panel.
• Remove supplied filters (if installed).
• Tap the filter against one side to align with outside
opening.
• Pull the filter down into the lower slots at the bottom
of the filter support.
Junction
Box
• Place the filter drip trays into the horizontal channel
in the filter panel, located behind the filters. The
grease will drain from the filters into these trays.
“C” Clip
• Insert the filter into the “C” clips mounted to the top
of the vertical front panel.
Filter
Support
Filters
• Position the filter in the lower slots at the bottom of
the filter support.
INSTALL CONTROL KNOBS
12
• To remove the filters, grasp the handle, push the filter
up and pull forward.
1 Ft = 0.3 m
1” = 2.5 cm
• Push control knobs onto the shafts.
FINALIZE INSTALLATION
13
• Refer to the operating instructions to test all controls.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
Notes.
OpeagIructions
rdCleaing
T
rubleshotingT
ips
CnsmeSuport
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Before you call for service…
Troubleshooting Tips
Save time and money! Review the charts on the following
pages first and you may not need to call for service.
Problem
Possible Causes
What To Do
SafeyIructions
Fan does not operate
when the switch is on
A fuse may be blown or a
circuit breaker tripped.
•Replace fuse or reset circuit breaker.
The blower connector is loose •Disconnect power to the unit. Remove the filters
or not plugged into its mating
connector.
and look up at the blower. If the blower connector
plug is loose or you see the connector dangling,
the installer failed to plug it in securely. Although it
is a blind connection, it is easy to plug in. See the
Installation Instructions in this manual for the plug
location and how to plug the connector in.
Fan fails to circulate air
or moves air slower than
normal
Excessively soiled filters.
•Remove the filters, clean if necessary and replace
them. If cleaning and replacing the filters does not
correct the problem, call for service.
OpeagIructions
rdCleaing
ips
rubleshotingT
T
CnsmeSuport
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Please place in envelope and mail to:
Veuillez mettre dans une enveloppe et envoyez à :
OWNERSHIP REGISTRATION
P.O. BOX 1780
MISSISSAUGA, ONTARIO
L4Y 4G1
(FOR CANADIAN CONSUMERS ONLY -
POUR RÉSIDENTS CANADIENS SEULEMENT)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNERSHIP REGISTRATION CERTIFICATE – FICHE D’INSCRIPTION DU PROPRIÉTAIRE
Please register your product to enable us to contact you in Veuillez enregistrer votre produit afin de nous permettre de
the remote event a safety notice is issued for this product communiquer avec vous si jamais un avis de sécurité concernant
and to allow for efficient communication under the terms of ce produit était émis et de communiquer facilement avec vous en
our warranty, should the need arise.
REGISTER ON-LINE:
ENREGISTREMENT SUR INTERNET À :
vertu de votre garantie, si le besoin s’en fait sentir.
MAIL TO:
P.O. BOX 1780, MISSISSAUGA
POSTEZ À :
ONTARIO, L4Y 4G1
FIRST NAME / PRÉNOM
LAST NAME / NOM
MR. / M.
MRS. / MME
MS.
MISS/MLLE
For Canadian
Customers
STREET NO / NO RUE
STREET NAME / RUE
APT.NO/APP./RR#
POSTAL CODE/CODE POSTAL
CITY / VILLE
PROVINCE
AREA CODE/ IND. RÉG.
TELEPHONE/TÉLÉPHONE
E-MAIL/COURRIEL
IF YES/SI OUI : EXPIRATION
YES/OUI
DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE?
AVEZ-VOUS ACHETÉ UN CONTRAT DE SERVICE POUR CET APPAREIL ?
NAME OF SELLING DEALER / NOM DU MARCHAND
Y/A
M
D/J
NO/NON
Pour les
MODEL / MODÈLE
consommateurs
canadiens
INSTALLATION DATE / DATE D’INSTALLATION
CORRESPONDENCE
ENGLISH
FRANÇAIS
Y/A
M
D/J
CORRESPONDANCE
SERIAL / SÉRIE
I do not wish to receive any promotional offers regarding this product.
Je ne désire pas recevoir d’offres promotionnelles concernant ce produit
.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
Range Hood Warranty.
All warranty service provided by our Factory Service Centers, or
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
an authorized Customer Care® technician. To schedule service,
1.800.561.3344.
For The Period Of: Mabe Will Replace:
One Year
From the date of the
original purchase
Any part of the range hood which fails due to a defect in materials or workmanship.
During this full one-year warranty, Mabe will also provide, free of charge, all labor and
in-home service to replace the defective part.
OpeagIructions
What Mabe Will Not Cover:
■Damage to the product caused by accident, fire, floods
or acts of God.
■Service trips to your home to teach you how to use
the product.
■Incidental or consequential damage caused by possible
defects with this appliance.
■Improper installation, delivery or maintenance.
■Failure of the product if it is abused, misused, or
used for other than the intended purpose or used
commercially.
■Damage caused after delivery.
rdCleaing
■Replacement of house fuses or resetting of circuit
breakers.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within Canada. If the product is located in an area where service by a Mabe Authorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the product to an Authorized Mabe Service
Location for service.
T
r
ubleshotingT
Some provinces do not allow the exclusion or limitation of incidental or consequential damages. This warranty
gives you specific legal rights, and you may also have other rights which vary from province to province. To know
what your legal rights are, consult your local or provincial consumer affairs office.
ips
CnsmeSuport
Warrantor: Mabe Canada Inc. Burlington, Ontario
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Consumer Support.
GE Appliances Website
GEAppliances.ca
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day,
any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals,
order parts or even schedule service on-line.
Schedule Service
GEAppliances.ca
Expert Mabe repair service is only one step away from your door. Get on-line and schedule your service at
your convenience 24 hours any day of the year! Or call 1-800-461-3636 during normal business hours.
Extended Warranties
GEAppliances.ca
Purchase a GE extended warranty and learn about special discounts that are available while your warranty
is still in effect. You can purchase it on-line anytime, or call 1-888-261-2133 during normal business hours.
Mabe Consumer Home Services will still be there after your warranty expires.
Parts and Accessories
GEAppliances.ca
Individuals qualified to service their own appliances can have parts or accessories sent directly to their
homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or
by phone at 1-800-661-1616 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally
should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause
unsafe operation.
Contact Us
GEAppliances.ca
If you are not satisfied with the service you receive from Mabe, contact us on our Website with all the details
including your phone number, or write to: General Manager, Customer Relations, Mabe Canada Inc.
Suite 310, 1 Factory Lane
Moncton, N.B. E1C 9M3
Register Your Appliance
GEAppliances.ca
Register your new appliance on-line—at your convenience! Timely product registration will allow for
enhanced communication and prompt service under the terms of your warranty, should the need arise.
You may also mail in the pre-printed registration card included in the packing material.
Download from Www.Somanuals.com. All Manuals Search And Download.
|