Delta Electronics Power Supply Series E48SH User Manual

FEATURES  
High efficiency: 92.0% @3.3V/30A  
Size: 58.4mm x 22.8mm x9.5mm  
(2.30”x0.90”x0.37”)  
Industry standard pin out  
Fixed frequency operation  
Input UVLO, Output OTP, OCP, OVP  
Monotonic startup into normal and  
pre-biased loads  
Secondary control, very fast transient  
response  
2250V Isolation and basic insulation  
No minimum load required  
No negative current during power or enable  
on/off  
ISO 9001, TL 9000, ISO 14001, QS 9000,  
OHSAS 18001 certified manufacturing facility  
UL/cUL 60950 (US & Canada) recognized,  
and TUV (EN60950) certified  
CE mark meets 73/23/EEC and 93/68/EEC  
directive  
Delphi Series E48SH, 120W Eighth Brick Family  
DC/DC Power Modules: 48V in, 3.3V/30A out  
The Delphi Series E48SH Eighth Brick, 48V input, single output, isolated  
DC/DC converters are the latest offering from a world leader in power  
systems technology and manufacturing Delta Electronics, Inc. This  
product family is available in either a through-hole or surface-mounted  
package and provides up to 120 watts of power or 50A of output current  
(1.2V and below) in an industry standard footprint and pinout. The E48SH  
converter operates from an input voltage of 36V to 75V and is available in  
output voltages from 1.0V to 15V. Efficiency is up to 92.0% for 3.3V  
output at 30A full load. With creative design technology and optimization  
of component placement, these converters possess outstanding  
electrical and thermal performance, as well as extremely high reliability  
under highly stressful operating conditions. All models are fully protected  
from abnormal input/output voltage, current, and temperature conditions.  
The Delphi Series converters meet all safety requirements with basic  
insulation.  
OPTIONS  
Positive On/Off logic  
Short pin lengths available  
External Synchronization  
Output OVP latch mode  
Output OCP latch mode  
Heat spreader  
APPLICATIONS  
Telecom/DataCom  
Wireless Networks  
Optical Network Equipment  
Server and Data Storage  
Industrial/Test Equipment  
DATASHEET  
DS_E48SH3R330_02162007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Figure 1: Efficiency vs. load current for minimum, nominal, and  
maximum input voltage at 25°C  
Figure 2: Power dissipation vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
4
3.5  
3
2.5  
2
1.5  
1
0.5  
0
30  
38  
46  
54  
62  
70  
78  
INPUT VOLTAGE(V)  
Figure 3: Typical full load input characteristics at room  
temperature  
E48SH3R330_02162007  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
For Negative Remote On/Off Logic  
Figure 4: Turn-on transient at zero load current (5 ms/div).  
Vin=48V.Top Trace: Vout, 2V/div; Bottom Trace: ON/OFF input,  
2V/div  
Figure 5: Turn-on transient at full rated load current (constant  
current load) (5 ms/div). Vin=48V.Top Trace: Vout, 2V/div;  
Bottom Trace: ON/OFF input, 2V/div  
For Input Voltage Start up  
Figure 6: Turn-on transient at zero load current (5 ms/div).  
Vin=48V.Top Trace: Vout, 2V/div, Bottom Trace: input voltage,  
50V/div  
Figure 7: Turn-on transient at full rated load current (constant  
current load) (5 ms/div). Vin=48V.Top Trace: Vout, 2V/div;  
Bottom Trace: input voltage, 50V/div  
E48SH3R330_02162007  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Figure 8: Output voltage response to step-change in load  
current (75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF,  
tantalum capacitor and 1µF ceramic capacitor. Trace: Vout  
(50mV/div, 100us/div), Scope measurement should be made  
using a BNC cable (length shorter than 20 inches). Position the  
load between 51 mm to 76 mm (2 inches to 3 inches) from the  
module..  
Figure 9: Output voltage response to step-change in load  
current (50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF,  
tantalum capacitor and 1µF ceramic capacitor. Trace: Vout  
(50mV/div, 100us/div), Scope measurement should be made  
using a BNC cable (length shorter than 20 inches). Position the  
load between 51 mm to 76 mm (2 inches to 3 inches) from the  
module..  
Figure 10: Test set-up diagram showing measurement points  
for Input Terminal Ripple Current and Input Reflected Ripple  
Current.  
Figure 11: Input Terminal Ripple Current, ic, at full rated output  
current and nominal input voltage with 12µH source impedance  
and 33µF electrolytic capacitor (200 mA/div, 2us/div).  
Note: Measured input reflected-ripple current with a simulated  
source Inductance (LTEST) of 12 µH. Capacitor Cs offset  
possible battery impedance. Measure current as shown above  
E48SH3R330_02162007  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Copper Strip  
Vo(+)  
Vo(-)  
SCOPE  
RESISTIVE  
LOAD  
10u  
1u  
Figure 12: Input reflected ripple current, is, through a 12µH  
source inductor at nominal input voltage and rated load current  
(20 mA/div, 2us/div).  
Figure 13: Output voltage noise and ripple measurement test  
setup  
Figure 14: Output voltage ripple at nominal input voltage and  
rated load current (Io=30A)(50 mV/div, 2us/div)  
Figure 15: Output voltage vs. load current showing typical  
current limit curves and converter shutdown points.  
Load capacitance: 1µF ceramic capacitor and 10µF tantalum  
capacitor. Bandwidth: 20 MHz. Scope measurements should be  
made using a BNC cable (length shorter than 20 inches).  
Position the load between 51 mm to 76 mm (2 inches to 3  
inches) from the module.  
E48SH3R330_02162007  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN CONSIDERATIONS  
The input source must be insulated from the ac  
mains by reinforced or double insulation.  
Input Source Impedance  
The impedance of the input source connecting to the  
DC/DC power modules will interact with the modules and  
affect the stability. A low ac-impedance input source is  
recommended. If the source inductance is more than a  
few µH, we advise adding a 10µF to 100µF electrolytic  
capacitor (ESR < 0.7 at 100 kHz) mounted close to the  
input of the module to improve the stability.  
The input terminals of the module are not operator  
accessible.  
If the metal baseplate is grounded, one Vi pin and  
one Vo pin shall also be grounded.  
A SELV reliability test is conducted on the system  
where the module is used, in combination with the  
module, to ensure that under a single fault,  
hazardous voltage does not appear at the module’s  
output.  
Layout and EMC Considerations  
Delta’s DC/DC power modules are designed to operate  
in a wide variety of systems and applications. For design  
assistance with EMC compliance and related PWB  
layout issues, please contact Delta’s technical support  
team. An external input filter module is available for  
easier EMC compliance design. Application notes to  
assist designers in addressing these issues are pending  
release.  
When installed into a Class II equipment (without  
grounding), spacing consideration should be given to  
the end-use installation, as the spacing between the  
module and mounting surface have not been evaluated.  
The power module has extra-low voltage (ELV) outputs  
when all inputs are ELV.  
Safety Considerations  
This power module is not internally fused. To achieve  
optimum safety and system protection, an input line fuse  
is highly recommended. The safety agencies require a  
normal-blow fuse with 10A maximum rating to be  
installed in the ungrounded lead. A lower rated fuse can  
be used based on the maximum inrush transient energy  
and maximum input current.  
The power module must be installed in compliance with  
the spacing and separation requirements of the  
end-user’s safety agency standard, i.e., UL60950,  
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and  
IEC60950-1999, if the system in which the power module  
is to be used must meet safety agency requirements.  
Basic insulation based on 75 Vdc input is provided  
between the input and output of the module for the  
purpose of applying insulation requirements when the  
input to this DC-to-DC converter is identified as TNV-2 or  
SELV. An additional evaluation is needed if the source  
is other than TNV-2 or SELV.  
Soldering and Cleaning Considerations  
Post solder cleaning is usually the final board assembly  
process before the board or system undergoes electrical  
testing. Inadequate cleaning and/or drying may lower the  
reliability of a power module and severely affect the  
finished circuit board assembly test. Adequate cleaning  
and/or drying is especially important for un-encapsulated  
and/or open frame type power modules. For assistance  
on appropriate soldering and cleaning procedures,  
please contact Delta’s technical support team.  
When the input source is SELV circuit, the power module  
meets SELV (safety extra-low voltage) requirements. If  
the input source is a hazardous voltage which is greater  
than 60 Vdc and less than or equal to 75 Vdc, for the  
module’s output to meet SELV requirements, all of the  
following must be met:  
E48SH3R330_02162007  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES DESCRIPTIONS  
Vi(+)  
Vo(+)  
Over-Current Protection  
Sense(+)  
The E48SH modules include an internal output  
over-current protection circuit, which will endure current  
limiting for an unlimited duration during output overload.  
When the output current exceeds the OCP set point, the  
current limit function will work by initially reduce duty  
cycle of the module, the unit will go out of regulation but  
remains in safe operating area before the output drops  
below 50%. When output drops below 50%, the  
modules will automatically shut down and enter hiccup  
mode.  
ON/OFF  
Sense(-)  
Vi(-)  
Vo(-)  
Figure 16: Remote on/off implementation  
Remote Sense  
During hiccup, the modules will try to restart after  
shutdown. If the overload condition still exists, the  
module will shut down again. This restart trial will  
continue until the overload condition is corrected.  
Remote sense compensates for voltage drops on the  
output by sensing the actual output voltage at the point  
of load. The voltage between the remote sense pins  
and the output terminals must not exceed the output  
voltage sense range given here:  
Over-Voltage Protection  
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] 10% × Vout  
The modules include an internal output over-voltage  
protection circuit, which monitors the voltage on the  
output terminals. If this voltage exceeds the over-voltage  
set point, the module will shut down and restart after  
200mS. latch off mode is optional. Under latch off mode  
the over-voltage latch is reset by either cycling the input  
power or by toggling the on/off signal for one second.  
This limit includes any increase in voltage due to  
remote sense compensation and output voltage set  
point adjustment (trim).  
Vi(+) Vo(+)  
Sense(+)  
Over-Temperature Protection  
The over-temperature protection consists of circuitry  
that provides protection from thermal damage. If the  
temperature exceeds the over-temperature threshold  
the module will shut down.  
Sense(-)  
Vi(-) Vo(-)  
Contact  
Resistance  
Contact and Distribution  
Losses  
The module will try to restart after shutdown. If the  
over-temperature condition still exists during restart, the  
module will shut down again. This restart trial will  
continue until the temperature is within specification.  
Figure 17: Effective circuit configuration for remote sense  
operation  
If the remote sense feature is not used to regulate the  
output at the point of load, please connect SENSE(+) to  
Vo(+) and SENSE(–) to Vo(–) at the module.  
Remote On/Off  
The remote on/off feature on the module can be either  
negative or positive logic. Negative logic turns the  
module on during a logic low and off during a logic high.  
Positive logic turns the modules on during a logic high  
and off during a logic low.  
The output voltage can be increased by both the  
remote sense and the trim; however, the maximum  
increase is the larger of either the remote sense or the  
trim, not the sum of both.  
Remote on/off can be controlled by an external switch  
between the on/off terminal and the Vi(-) terminal. The  
switch can be an open collector or open drain.  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
For negative logic if the remote on/off feature is not  
used, please short the on/off pin to Vi(-). For positive  
logic if the remote on/off feature is not used, please  
leave the on/off pin to floating.  
Care should be taken to ensure that the maximum  
output power does not exceed the maximum rated  
power.  
E48SH3R330_02162007  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES DESCRIPTIONS (CON.)  
If the external resistor is connected between the TRIM  
and SENSE (+) the output voltage set point increases  
(Fig. 19). The external resistor value required to obtain  
a percentage output voltage change % is defined  
as:  
Output Voltage Adjustment (TRIM)  
To increase or decrease the output voltage set point,  
the modules may be connected with an external  
resistor between the TRIM pin and either the  
SENSE(+) or SENSE(-). The TRIM pin should be left  
open if this feature is not used.  
5.11Vo (100 + ∆ ) 511  
Rtrim up =  
10.2(KΩ  
)
1.225 ∆  
Ex. When Trim-up +10%(3V×1.1=3.3V)  
5.11× 3.3× (100 +10 ) 511  
Rtrim up =  
10.2 = 90.1 KΩ  
(
)
1.225×10  
10  
The output voltage can be increased by both the remote  
sense and the trim, however the maximum increase is  
the larger of either the remote sense or the trim, not the  
sum of both.  
Figure 18: Circuit configuration for trim-down (decrease  
output voltage)  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
If the external resistor is connected between the TRIM  
and SENSE (-) pins, the output voltage set point  
decreases (Fig. 18). The external resistor value  
required to obtain a percentage of output voltage  
change % is defined as:  
Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
511  
Rtrim down =  
10.2(K)  
Frequency Synchronization  
Ex. When Trim-down -10%(3.3V×0.9=2.97V)  
This product family can be synchronized with external clock  
signal to the TRIM pin. This reduces system noise and  
interference in multiple converter systems.  
511  
Rtrim down =  
10.2 = 40.9(K)  
10  
Figure 19: Circuit configuration for trim-up (increase output  
voltage)  
E48SH3R330_02162007  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thermal Derating  
THERMAL CONSIDERATIONS  
Heat can be removed by increasing airflow over the  
module. The hottest point temperature of the module is  
129. To enhance system reliability; the power module  
should always be operated below the maximum  
operating temperature. If the temperature exceeds the  
maximum module temperature, reliability of the unit may  
be affected.  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
THERMAL CURVES  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel. The space between the neighboring PWB  
and the top of the power module is constantly kept at  
6.35mm (0.25’’).  
Figure 21: Case temperature measurement location.  
Pin locations are for reference only.  
The allowed maximum hot spot temperature is defined at  
129℃  
E48SH3R330(Standard) Output Current vs. Ambient Temperature and Air Velocity  
Output Current(A)  
@Vin = 48V (Transverse Orientation)  
30  
25  
20  
15  
10  
5
PWB  
MODULE  
FACING PWB  
Natural  
Convection  
100LFM  
200LFM  
300LFM  
AIR VELOCITY  
400LFM  
AND AMBIENT  
TEMPERATURE  
MEASURED BELOW  
THE MODULE  
50.8 (2.0”)  
AIR FLOW  
0
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
12.7 (0.5”)  
Figure 22: Output current vs. ambient temperature and air  
velocity @ Vin=48V (Transverse Orientation)  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 20: Wind tunnel test setup  
E48SH3R330_02162007  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PICK AND PLACE LOCATION  
SURFACE-MOUNT TAPE & REEL  
RECOMMENDED PAD LAYOUT (SMD)  
E48SH3R330_02162007  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE  
Peak temp.  
2nd Ramp-up temp.  
210~230°C 5sec.  
1.0~3.0°C /sec.  
250  
Pre-heat temp.  
140~180°C 60~120 sec.  
200  
Cooling down rate <3°C /sec.  
Ramp-up temp.  
0.5~3.0°C /sec.  
150  
100  
50  
Over 200°C  
40~50sec.  
0
60  
120  
Time ( sec. )  
180  
240  
300  
Note: The temperature refers to the pin of E48SH, measured on the pin +Vout joint.  
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE  
.
Temp  
Peak Temp. 240 ~ 245  
217℃  
200℃  
Ramp down  
max. 4/sec.  
Preheat time  
100~140 sec.  
150℃  
25℃  
Time Limited 90 sec.  
above 217℃  
Ramp up  
max. 3/sec.  
Time  
Note: The temperature refers to the pin of E48SH, measured on the pin +Vout joint.  
E48SH3R330_02162007  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MECHANICAL DRAWING  
SURFACE-MOUNT MODULE  
THROUGH-HOLE MODULE  
Pin No.  
Name  
Function  
1
2
3
4
5
6
7
8
+Vin  
ON/OFF  
-Vin  
-Vout  
-SENSE  
TRIM  
Positive input voltage  
Remote ON/OFF  
Negative input voltage  
Negative output voltage  
Negative remote sense  
Output voltage trim  
+SENSE  
+Vout  
Positive remote sense  
Positive output voltage  
E48SH3R330_02162007  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MECHANICAL DRAWING (WITH HEATSPREADER)  
THROUGH-HOLE MODULE  
E48SH3R330_02162007  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PART NUMBERING SYSTEM  
E
48  
S
H
3R3  
30  
N
R
F
A
Type of  
Product  
Input  
Voltage  
Number of Product  
Outputs Series  
Output  
Voltage  
Output  
Current  
30 - 30A  
ON/OFF  
Logic  
N- Negative  
Pin Length  
Option Code  
E- Eighth 48-36V~75V S- Single H-50A series 3R3 - 3.3V  
Brick  
R- 0.170”  
N- 0.145”  
K- 0.110”  
M- SMD  
A- Standard functions  
H - With heatspreader  
F- RoHS 6/6  
(Lead Free)  
P- Positive  
MODEL LIST  
MODEL NAME  
E48SH1R250NRFA  
E48SH1R540NRFA  
E48SH1R840NRFA  
E48SH2R535NRFA  
E48SH3R330NRFA  
E48SH05020NRFA  
E48SH12010NRFA  
INPUT  
OUTPUT  
EFF @ 100% LOAD  
36V~75V  
36V~75V  
36V~75V  
36V~75V  
36V~75V  
36V~75V  
36V~75V  
2.3A  
2.2A  
2.7A  
2.9A  
3.6A  
3.7A  
4.3A  
1.2V  
1.5V  
1.8V  
2.5V  
3.3V  
5.0V  
12V  
50A  
40A  
40A  
35A  
30A  
20A  
10A  
86.5%  
89%  
90%  
89.5%  
92%  
90%  
93.5%  
Default remote on/off logic is negative and pin length is 0.170”  
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales  
office.  
USA:  
Telephone:  
East Coast: (888) 335 8201  
West Coast: (888) 335 8208  
Fax: (978) 656 3964  
Europe:  
Asia & the rest of world:  
Telephone: +886 3 4526107 x 6220  
Fax: +886 3 4513485  
Telephone: +41 31 998 53 11  
Fax: +41 31 998 53 53  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon  
request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for  
its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is  
granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these  
specifications at any time, without notice.  
E48SH3R330_02162007  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Lighting Indoor Furnishings BI Series User Manual
Craftsman Chainsaw 316350840 User Manual
Dacor Oven GlideRack User Manual
Delta Electronics Power Supply SILM730 User Manual
Dimplex Indoor Fireplace 7206260100REV00 User Manual
Dual DVD Player DP295 User Manual
Dukane Projector 8107WIB User Manual
Dynex Flat Panel Television DX PDP42 09 User Manual
Edelbrock Automobile Parts E TEC 170 User Manual
GE Monogram Microwave Oven ZEM200WV User Manual