NAME OF PARTS
1 Start/Stop Button
Display
2 Set Temperature Button
3 Master Control Button
4 Fan Control Button
5 THERMO SENSOR Button
6 ENERGY SAVE Button
7 Timer Mode (CLOCK ADJUST) Button
8 DAY (DAY OFF) Button
9 SET BACK Button
SU MO TU WE TH FR SA
3
6
9
12 15 18 21
t
1
2
7
DAY
3
4
5
6
CLOCK ADJUST
SET BACK
DAY OFF
ENERGY
SAVE
THERMO
SENSOR
8
9
DELETE
SET
0
0 Set Time Button
q DELETE Button
w SET Button
q
w
e
r
e Button cannot be operated. *1
r Button cannot be operated. *1
t Operation Lamp
Display panel
y
o p i
u
SU MO TU WE TH FR SA
y Timer and Clock Display
u Operation Mode Display
i Fan Speed Display
o Operation Lock Display
p Temperature Display
a Defrost Display
3
6
9
12 15 18 21
a
d
s
s Thermo Sensor Display
d Energy Save Display
*1: If e, r buttons are pressed, the operation lock display flashes,
but the air conditioner will not respond.
PREPARATORY OPERATION
To set the current day and time
Press the DAY button and select the current day.
appears around the selected day.
DAY
A
1
2
CLOCK ADJU
DAY OF
Press the TIMER MODE button for 2
seconds or more. The time display on
the remote controller will flash.
SU
MO
TU
WE
TH
FR
SA
SU MO TU WE TH FR SA
3
CLOCK ADJU
ex. Monday, 10:00 A.M.
Press again to end.
Press the SET TIME buttons to set the current time.
Press repeatedly to adjust the current time in 1-minute increments. Press and
hold to adjust the current time in 10-minute increments.
En-2
OM_9373117063-en.indd Sec1:2
9/10/07 5:16:09 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle).
To start/stop operation
Press the START/STOP button.
Operation lamp
Air conditioner ON: Lit brightly
Air conditioner OFF: Not lit
To set the operation mode
Press the MASTER CONTROL button to set the operation mode.
If DRY is selected, the fan speed will be set to AUTO.
Operation mode setting
AUTO
COOL
DRY
FAN
HEAT
Press the SET TEMPERATURE buttons to set the room temperature.
Room temperature setting
Temperature setting range
AUTO ............................................................ 64 to 88 °F
COOL/DRY .................................................... 64 to 88 °F
HEAT ............................................................. 60 to 88 °F*
Lower
Raise
Press the FAN CONTROL button to set the fan speed.
Fan speed setting
AUTO
HIGH
MED
LOW
Press the ENERGY SAVE button to start or stop the energy-
saving air conditioner operation.
For details on th function, refer to page 9.
Energy save setting
ENERGY
SAVE
En-3
OM_9373117063-en.indd Sec1:3
9/10/07 5:16:09 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Room temperature sensor selection
THERMO
SENSOR
Indoor unit
Press the THERMO SENSOR button to select whether the
room temperature is detected at the indoor unit (remote
sensor) or the remote controller.
When the
thermo sensor display appears, the room
temperature is detected at the remote controller.
NOTES
•
•
This function is locked at the factory. In order to detect the room temperature correctly, consult authorized service
personnel when using this function.
If this function is locked, the location where the room temperature is detected cannot be changed and the
mark flashes when the THERMO SENSOR button is pushed.
Part lock function
Press the DAY (DAY OFF) button and SET button
simultaneously for 2 seconds or more to activate the
part lock function and lock all of the buttons on the
remote controller except the Start/Stop button, Set
Temperature buttons, Master Control button, and Fan
Control button. Press the buttons again for 2 seconds
or more to deactivate the part lock function.
DAY
CLOCK ADJUST
SET BACK
DAY OF
SET
DELETE
When the part lock function is activated, the
mark appears. If any button is pressed during the part
lock, the PL display flashes.
ON/OFF TIMER
Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle).
To set the ON/OFF timer
Press the TIMER MODE button
to select the ON TIMER or OFF
TIMER.
SU MO TU WE TH FR SA
1
2
CLOCK ADJUS
From 1 to 24 hours
ex. OFF timer set for 6 hours
No display
Press the SET TIME buttons to set the time.
After the time is set, the timer will start automatically.
The amount of time until the OFF timer operates that
is displayed on the timer display decreases as time
passes.
NON
STOP
OFF
TIMER
ON
TIMER
WEEKLY
TIMER
To cancel the timer mode
•
•
Press the DELETE button to cancel the timer mode.
The timer mode can also be canceled by changing the timer mode using the TIMER MODE
button.
DELETE
En-4
OM_9373117063-en.indd Sec1:4
9/10/07 5:16:10 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
WEEKLY TIMER
Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle).
To set the WEEKLY timer
SET
SU MO TU WE TH FR SA
1
2
CLOCK ADJUS
3
6
9
12 15 18 21
Press the TIMER MODE button to select the weekly timer.
Press the SET button for 2 seconds
or more.
Day of the week setting
3
ALL
SU
MO
TU
WE
TH
FR
SA
SET
DAY
DAY OF
2
1
SU MO TU WE TH FR SA
Press the DAY button to select the day of the week, and then press the
SET button to confirm the setting.
3
6
9
12 15 18 21
*
For ALL, all of the days can be set together when a
each day.
appears around
Time setting
When the operating time is set, the
mark appears.
4
SET
SU MO TU WE TH FR SA
2
1
ON-1
OFF-1
ON-2
OFF-2
3
6
9
12 15 18 21
ex. The timer is set for 7:00 A.M.–6:00 P.M.
(7:00–18:00)
Press the SET TIME buttons to set the ON time in 30-minute increments, then press the SET button to proceed to the
OFF time setting. Set the OFF time in the same way.
If necessary, set the second weekly timer settings in the same way.
To delete the operating time
SET
DELETE
5
6
Repeat steps 3 and 4 to Press the SET button for 2 If the DELETE button is pressed during steps 3 or 4, the
set the weekly timer for seconds or more to com- operating time for the selected day will be deleted.
another day of the week. plete the weekly timer set- If all the days are selected, the operating times for all of the
tings.
days will be deleted.
En-5
OM_9373117063-en.indd Sec1:5
9/10/07 5:16:11 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
WEEKLY TIMER
To start/cancel the WEEKLY timer operation
To start
To cancel
SU MO TU WE TH FR SA
DELETE
3
6
9
12 15 18 21
CLOCK ADJUS
•
•
Press the DELETE button to
cancel the timer mode.
The timer mode can also be
canceled by changing the timer
mode using the TIMER MODE
button.
When the weekly timer is selected, the
timer starts automatically.
3
6
9
12 15 18 21
ex.Operating time 7:00 A.M.
–6:00 P.M. (7:00–18:00)
The operating time for the current
day is displayed.
NOTES
(1) PRECAUTIONS DURING WEEKLY TIMER SETUP
Setup is not possible in the following cases, so amend
the time.
(2) The earliest OFF time you can set is 30 minutes after
the ON time.
(3) The OFF time can be carried over to the next day.
(4) Even if the timer operation is set, the timer indicator
lamp of the indoor unit does not light up. (The timer
indicator lamp is used for wireless remote controllers
• Be sure to set the ON time first, then the OFF time.
If either the ON time or the OFF time is not set
correctly, the timer will not operate properly.
• The WEEKLY 2 settings cannot be set earlier than
the WEEKLY 1 settings.
only.)
• The WEEKLY 1 and WEEKLY 2 time spans cannot
overlap.
To set the DAY OFF (for a holiday)
DAY
DAY
SET
SET
1
2
3
4
DAY OF
DAY OF
During the weekly timer, Select the day to set the Press the DAY (DAY OFF) Press the SET button for 2
press the SET button for DAY OFF.
2 seconds or more to set
the day.
button for 2 seconds or secondsormoretocomplete
more to set the DAY OFF. the DAY OFF setting.
SU MO TU WE TH FR SA
SU MO TU WE TH FR SA
mark: Indicates the DAY OFF
To cancel
3
6
9
12 15 18 21
3
6
9
12 15 18 21
Follow the same procedures as
those for setup.
ex. The DAY OFF is set for Monday.
NOTES
(1) The DAY OFF setting is only available for days for which weekly settings already exist.
(2) If the operating time carries over to the next day (during a next day setting), the effective DAY OFF range will be
set as shown below.
Normal
Next day setting
DAY OFF
DAY OFF
ON
ON
OFF
WEEKLY
Preceding day
ON
WEEKLY
Setting day
OFF
ON
OFF
OFF
WEEKLY
WEEKLY
Next day
Preceding day
Setting day
Next day
(3) The DAY OFF setting can only be set one time. The DAY OFF setting is cancelled automatically after the set day
has passed.
En-6
OM_9373117063-en.indd Sec1:6
9/10/07 5:16:12 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
TEMPERATURE SET BACK TIMER
Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle).
To set the temperature SET BACK timer
SET BACK
SET
SU MO TU WE TH FR SA
If there is no existing
SET BACK tempera-
ture setting, “- -” will
be displayed for the
temperature.
1
2
3
6
9
12 15 18 21
Press the SET BACK button to change to the SET BACK confirmation display.
The SET BACK operating time and the set temperature will be displayed.
Press the SET button for 2
seconds or more.
Day setting
Operating time setting
SU MO TU WE TH FR SA
3
SET
SET
DAY
3
6
9
12 15 18 21
DAY OF
ex. When setting all days together
4
2
1
3
Follow steps 3and 4in “To set the WEEKLY timer” (p. 6). The DELETE button is also used as described in the procedures
for the weekly timer.
SET
Press the SET TEMPERATURE buttons to
set the temperature (from 48 °F to 88 °F).
Temperature setting
4
5
SU MO TU WE TH FR SA
3
6
9
12 15 18 21
Repeat steps 3 and 4.
Press the SET button for 2
seconds or more to com-
plete the temperature SET
BACK timer settings.
ex. Operating time 3:00–10:00 P.M.
(15:00–22:00)
SET BACK
temperature
ON 84°F OFF
76°F
76°F
Normal
temperature
To start/cancel the temperature SET BACK timer operation
To start
To cancel
SU MO TU WE TH FR SA
SET BACK
DELETE
SET BACK
2
1
ex. Display during SET BACK timer operation
(The operating time will not be displayed.)
Press the SET BACK button, and then press the DELETE
Press the SET BACK button. The SET BACK confirmation
button while the SET BACK confirmation display is dis-
display appears for 5 seconds, and then the timer starts played. Even if the SET BACK button is pressed again, the
automatically.
SET BACK timer will be cancelled.
NOTES
(1) The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner
operation.
(2) The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be
used.
(3) The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
(4) The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET
BACK confirmation display.)
En-7
OM_9373117063-en.indd Sec1:7
9/10/07 5:16:13 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
SELF-DIAGNOSIS
When the error indication “E:EE” is displayed, inspection of the air conditioning system is necessary. Please consult
authorized service personnel.
(1) Stop the air conditioner operation.
(2)
Faulty unit number
(remote controller address)
Error code
SU MO TU WE TH FR SA
SU MO TU WE TH FR SA
ex. Error display
ex. Self-diagnosis check
Press the SET TEMPERATURE buttons
simultaneously for 5 seconds or more to start the self-diagnosis.
/
(3) Press the SET TEMPERATURE buttons simultaneously for 5 seconds or more to stop the self-diagnosis.
OPERATING TIPS
Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Mode operation: AUTO
AUTO restart
COOLING MODEL
• Should the power supply to the air conditioner be
interrupted by a power failure, the air conditioner will
restart automatically in the previously selected mode
once the power is restored.
• When the room temperature is 4 °F higher than the set
temperature, the mode will switch between Cooling and
Drying.
• During the Drying mode operation, the FAN setting should
be switched to LOW for a gently cooling effect during
which the fan may temporarily stop rotating.
• Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
turn off the circuit breaker turn it on again and then use
the remote controller to resume operation.
HEAT & COOL MODEL (Reverse Cycle)
Auto changeover function
• When AUTO CHANGEOVER is selected, the air conditioner
selects the appropriate operation mode (Cooling or
Heating) according to your room’s present temperature.
• When AUTO CHANGEOVER is first selected, the fan will
stop or operate at a very low speed for about 1 minute
while the unit determines the current conditions of the
room and selects the proper operation mode.
• When the room temperature is near the thermostat
setting, the air conditioner will begin monitor operation.
In the monitor operation mode, the fan will stop or operate
at a very low speed. If the room temperature subsequently
changes, the air conditioner will once again select the
appropriate operation (Heating or Cooling) to adjust
the temperature to the value set in the thermostat. (The
monitor operation range is 4 °F relative to the thermostat
setting.)
Heating performance
• This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that
heat indoors. As a result, the operating performance is
reduced as outdoor air temperature drops. If you feel that
insufficient heating performance is being produced, we
recommend you use this air conditioner in conjunction
with another kind of heating appliance.
• Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result
that some time may be required after first starting the
air conditioner until the room is heated.
Fan speed: AUTO
Heating: The fan will stop or operate at a very low speed
if the temperature of the airflow from the indoor
unit is lower than the set temperature.
Cooling: As the room temperature approaches that of the
set temperature, the fan speed becomes slower.
Fan:
The fan alternately turns on and off; when on, the
fan runs at the low fan speed.
En-8
OM_9373117063-en.indd Sec1:8
9/10/07 5:16:14 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING TIPS
Energy save
Hot start (for heating)
• The energy conservation mode (ENERGY SAVE) raises the
set temperature slightly in the cooling mode and lowers
the set temperature in the heating mode to economically
control the operation of the unit.
• If you press the ENERGY SAVE button while the unit is
in the timer mode, the unit will go into the conservation
mode when the unit starts with the timer.
• If you turn off the air conditioner while in the conservation
mode, the mode will be shut off.
• The temperature set on the remote controller will not
change if the energy save mode is used.
The indoor unit prevents cold drafts when heating operation
begins.
The indoor unit fan will not operate or it will operate at a
very low speed until the heat exchanger reaches the set
temperature.
Defrosting (for heating)
When the outdoor temperature is low and the humidity
high, frost will collect on the outdoor unit, reducing heater
efficiency.
When this happens, the computer will automatically start
the defrost cycle. During the defrost cycle, the indoor fan
During cooling operation
When the ENERGY SAVE is
pressed, the thermostat setting
is automatically raised 2 °F every
82 F
will shutdown and
will be displayed on the remote
controller. It will take anywhere from 4 to 15 minutes before
the air conditioner starts up again.
80 F
60 min.
60 minutes, until the thermostat
78 F
is raised a total of 4 °F.
Group Control
Energy save
One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same
settings.
During heating operation
When the ENERGY SAVE is
pressed, the thermostat setting
74 F
72 F
70 F
30 min.
is automatically lowered 2 °F
68 F
Dual Remote Controllers (optional)
every 30 minutes, until the
thermostat is lowered a total
of 8 °F.
30 min.
66 F
30 min.
An additional remove controller can be added up to
the maximum of two remote controllers. Either remote
controller can control the air conditioner. However, the timer
functions cannot be used at the slave unit.
Energy save
En-9
OM_9373117063-en.indd Sec1:9
9/10/07 5:16:14 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING TIPS
Multi-type Air conditioner
This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units
to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective
output.
Simultaneous Use of Multiple Units
Instructions relating to inverter (v) are applicable only to “INVERTER MODEL”.
v
lOperation can be done in the following different
operating modes.
l
When using a multi-type air conditioner, the multiple
indoor units can be operated simultaneously, but when
two or more indoor units of the same group are operated
simultaneously, the heating and cooling efficiency will
be less than when a single indoor unit is used alone.
Accordingly, when you wish to use more than one indoor
unit for cooling at the same time, the use should be
concentrated at night and other times when less output
is required. In the same way, when multiple units are
used simultaneously for heating, it is recommended that
they be used in conjunction with other auxiliary space
heaters, as required.
Seasonal and outdoor temperature conditions, the
structure of the rooms and the number of persons present
may also result in differences of operating efficiency.
We recommend that you try various operating patterns
in order to confirm the level of heating and cooling
output provided by your units, and use the units in the
way that best matches your family’s lifestyle.
Cooling mode and dry mode
Cooling mode and fan mode
Dry mode and fan mode
v
lThe operating mode (heating mode or cooling (dry) mode)
of the outdoor unit will be determined by the operating
mode of the indoor unit that was operated first.
If the indoor unit was started in fan mode, the operating
mode of the outdoor unit will not be determined.
For example, if indoor unit (A) was started in fan mode
and then indoor unit (B) was then operated in heating
mode, indoor unit (A) would temporarily start operation
in fan mode but when indoor unit (B) started operating
l
in heating mode,
will be shown on the remote
controller display and it would go into standby mode.
Indoor unit (B) would continue to operate in heating
mode.
l
lf you discover that one or more units delivers a low level
of cooling or heating during simultaneous operation, we
recommend that you stop simultaneous operation of the
multiple units.
v
lOperation cannot be done in the following different
operating modes.
If the indoor unit is instructed to do an operating mode
that it cannot perform,
will be shown on the remote
controller display and the unit will go into the standby
mode.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
Notice
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
*lDuring use of the heating mode, the outdoor unit will
occasionally commence the defrost operation for brief
periods. During the defrosting operation, if the user sets
the indoor unit for heating again, the defrosting mode
will continue, and the heating operation will begin after
completion of defrosting, with the result that some time
may be required before warm air is emitted.
*lDuring use of the heating mode, the top of the indoor
unit may become warm, but this is due to the fact that
coolant is circulated through the indoor unit even when
it is stopped; it is not a malfunction.
En-10
OM_9373117063-en.indd Sec1:10
9/10/07 5:16:15 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
CAUTION!
Before cleaning the unit, be sure to stop the unit and power supply. (Turn off the electrical breaker)
Cleaning the air filter
If dirt is allowed to collect in the air filter, the airflow will be reduced, leading to reduced performance, and increased
operation noise. Be sure to clean the filters regularly.
How to cleaning
Use a vacuum cleaner to remove dust and dirt from the air filter, or wash in a synthetic detergent. After washing, dry in a
shaded place, then reinstall.
lWhen used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that
the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized
service personnel.
lWhen cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like
benzene or thinner.
lDo not expose the unit body to liquid insecticides or hairspray.
lIf the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.
En-11
OM_9373117063-en.indd Sec1:11
9/10/07 5:16:16 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
WARNING!
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker,
and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
Always be sure to turn off the electrical breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
Symptom
Problem
See Page
NORMAL Doesn’t operate imme-
FUNCTION diately:
l
l
If the unit is stopped and then immediately started again, the
compressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.
—
Noise is heard:
l
During operation and immediately after stopping the unit, the sound
of water flowing in the air conditioner’s piping may be heard. Also,
noise may be particularly noticeable for about 2 to 3 minutes after
starting operation (sound of coolant flowing).
—
l
l
l
During Heating operation, a sizzling sound may be heard
occasionally.
This sound is produced by the Automatic Defrosting operation.
9
Smells:
Some smell may be emitted from the indoor unit. This smell is the
result of room smells (furniture, tobacco, etc.) which have been
taken into the air conditioner.
—
Mist or steam are
emitted:
During Cooling, a thin mist may be seen emitted from the indoor
unit.
This results from the sudden Cooling of room air by the air emitted
from the air conditioner, resulting in condensation and misting.
—
l
During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to the Automatic
Defrosting operation.
9
Air flow is stopped:
l
l
When Heating operation starts, the fan will not operate or it will
operate at a very low speed to allow the internal parts to warm
up.
During Heating operation, if the room temperature rises above the
thermostat setting, the indoor and the outdoor unit will stop.
If you wish to warm the room further, set the thermostat to a higher
setting.
—
l
During Heating operation, the unit will temporarily stop operation
(between 7 and 15 minutes) as the Automatic Defrosting mode
9
operates. During the Automatic Defrosting operation,
shown on the remote controller display.
will be
l
l
The fan may stop or operate at a very low speed when the unit is
monitoring the room’s temperature.
—
In case of Multi-type unit, if multiple units are operated in different
operation modes as shown below, the units operated afterward
will stop and
of the stopped indoor units.
will be shown on the remote controller display
10
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
Water is produced from
the outdoor unit:
l
l
During Heating operation, water may be produced from the outdoor
unit due to the Automatic Defrosting operation.
9
The room temperature sensor may be malfunctioning. Please
consult authorized service personnel.
thermo sensor
display on the remote
controller is flashing:
—
En-12
OM_9373117063-en.indd Sec1:12
9/10/07 5:16:16 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Symptom
Items to check
Has there been a power failure?
See Page
CHECK ONCE Doesn’t operate at all:
l
l
—
MORE
Has a fuse blown out, or a circuit breaker been tripped?
l
Is the timer operating?
5 to 7
Poor Cooling (or Heating)
performance:
l
l
l
Is the air filter dirty?
Are the air conditioner’s intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat)
correctly?
l
l
Is there a window or door open?
—
In the case of Cooling operation, is a window allowing bright
sunlight to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus
and computers inside the room, or are there too many people
in the room?
l
If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off
the electrical breaker, and consult with authorized service personnel.
En-13