Frigidaire Dehumidifier 66129900901 User Manual

OWNER’S GUIDE  
READ AND SAVE THESE INSTRUCTIONS  
Record Model No. and Serial No. of this dehumidifier in space provided below. These numbers are  
printed on the nameplate located behind the bucket.  
M odel No. ___________________________________________________  
Serial No. ____________________________________________________  
IM PORTANT: Keep a copy of your bill of sale. The date on the bill establishes the warranty period  
should service be required. If service is performed, it is in your best interest to obtain and keep all  
receipts.  
Register Your Product  
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed, and  
returned to the Frigidaire Company.  
Contents  
2
3
3
3
4
Warranty  
Important Safety Instructions  
Location  
How It W orks  
OPERATION  
5
6
7
REMOVING COLLECTED WATER  
CARE AND CLEANING  
Avoid Service Checklist  
Operate dehumidifier only as instructed in this Owner’s Guide. These instructions are not meant to  
cover every possible condition and situation that may occur. Common sense and caution must be  
used when installing, operating, and maintaining any appliance.  
DEHUMIDIFIER  
P/N 66129900901  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Read all iinstructions before using this dehumidifier. To reduce the risk of fire,  
electric shock, or injury to persons when using your dehumidifier, follow basic  
precautions, including the following:  
Important Safety  
Instructions  
For Your Safety  
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of  
this or any other appliance. Read product labels for flammability and other warnings.  
Child Safety Precautions  
Avoid fire hazard or  
Destroy the carton, plastic bags, and any packing materials immediately after the  
dehumidifier is unpacked. Children should never use these items for play.  
Do not leave children unattended in an area where the appliance is operating.  
Do not allow them to sit or stand on the appliance.  
electric shock. Do not use an extension  
cord or an adaptor plug. Do not remove  
grounding prong from power cord.  
Grounding type  
w all receptacle  
Electrical Information  
For your safety and protection, this dehumidifier is equipped with a three-prong  
grounding plug on the power cord. Do nnot, under aany circumstances, cut oor  
remove the rround ground prong from the plug.  
Do not, under  
any circumstances,  
cut, remove,  
or bypass the  
grounding prong  
from this plug.  
Your dehumidifier must be plugged directly into a properly grounded and  
polarized three-prong receptacle. If the wall receptacle you intend to use will not  
accept a three-prong plug, or if you are not sure the outlet is adequately  
grounded or protected by a time delay fuse or circuit breaker, have a qualified  
electrician install the proper outlet according to the National Electrical Code and  
applicable local codes and ordinances. Do not use an extension cord or an  
adapter plug.  
Never unplug the dehumidifier by pulling on the power cord. Always grip the  
plug firmly and pull straight out from the receptacle.  
Do not pinch, bend, or knot the power cord.  
Selecting aa Location  
IM PORTANT:  
Location  
1. Dehumidifier must be operated in an enclosed area to bbe most effective.  
Close all doors, ww indow s, and other outside openings to the rroom. The  
effectiveness of the dehumidifier depends on the rate at w hich new  
moisture-laden air enters the room.  
2. Place dehumidifier in a location that does not restrict airflow through the  
front of the unit or out of the louvers on the left side of cabinet.  
3. A dehumidifier ooperating in a basement w ill hhave little or no eeffect in  
drying an adjacent enclosed storage aarea, such as a closet, unless there  
is adequate circulation of aair in and out of tthe area. IIt may be nnecessary  
to install a second dehumidifier in the enclosed area for satisfactory  
drying.  
4. The dehumidifier must be installed on a level floor that w ill support it  
w ith a full bucket of w ater.  
5. There should be a minimum of 12 inches clearance around the dehumi-  
difier.  
When the unit is started, the fan begins to pull moisture-laden air across the  
dehumidifying coils. The coils condense or draw moisture from the air, and air flows  
through the side louvers into the room as dry, warm air. Moisture removed from air  
is collected in a bucket on the front of the dehumidifier.  
How It W orks  
The unit is designed to operate between 41 F (5 C), and 96 F (35 C).  
If the unit is switched off and needs to be switched on again, wait three minutes  
before doing so.  
Make sure the tank is fitted correctly otherwise unit will not turn on.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
Allow the unit to reach room temperature before operating.  
To begin operating the dehumidifier, follow these steps:  
1. Plug the power cord into a properly grounded 110/120 volt AC outlet. Note the  
POWER indicators will illuminate.  
2. To turn the unit on rotate the knob until it points to the CONTINUOUS setting.  
It is recommended you leave the unit running in the CONTINUOUS setting for  
the first three or four days until the sweating and dampness odors have stopped.  
3. After a few days when the Relative Humidity has declined, rotate the  
HUMIDITY knob to a desired point on the dial so the room is kept at a  
comfortable concentration. The unit will cycle on and off keeping the desired level  
of comfort.  
Download from Www.Somanual4s.com. All Manuals Search And Download.  
4. To shut the unit down, rotate the HUMIDITY knob to the OFF position. Note:  
the power indicator will still be lit when the unit is turned off. Only removing the  
plug will extinguish these lights.  
REMOVING COLLECTED WATER  
1. Emptying the Bucket:  
a. When the bucket is full the unit will shut down and the BUCKET FULL  
indicator light will illuminate.  
b. Do not move the unit at this point otherwise water may spill on the floor.  
c. Press sides of bucket gently to unclip the bucket from the unit.  
d. Remove the bucket as shown in the photographs below and empty the  
bucket.  
e. Replace the empty bucket back into the unit and once seated correctly  
the unit will start up again.  
f. You should hear a click when the bucket is in the correct position  
If the bucket full light does not extinguish,  
check that the float is correctly snapped  
in place as indicated by the photo.  
Download from Www.Somanual5s.com. All Manuals Search And Download.  
2. Continuous Drainage:  
a. For constant drainage operation, you will need a garden hose and a  
drain nearby to discharge the water into.  
b. Remove the bucket from the unit and set aside.  
c. Lift up the side flap located on the left side of the unit as looking from  
the front. (fig.1)  
d. Insert the female threaded end of the hose through the opening. (fig.2)  
e. Screw the garden hose onto the threaded portion of the tray  
underneath the bucket opening. (fig.3)  
f. Make sure the hose is secure so there are not leaks.  
g. Direct the hose toward the drain making sure that there are no kinks  
that will stop the water flowing.  
h. Place the end of the hose into the drain.  
i. Place the bucket back in the unit and make sure that it is located  
correctly. (fig.4)  
j. Select the desired humidity setting and fan speed on the unit for  
continuous draining to start.  
fig.1  
fig.2  
fig.3  
fig.4  
Note: If the unit stops operating check that the bucket full light is illuminated. If it  
is remove the bucket and empty the contents and then check the seal between  
the hose and the drip tray. If there is a small leak then replace the hose gasket  
and re-tighten the hose.  
CARE AND CLEANING  
1. Filter  
a. Remove the filter every two weeks based  
on normal operating conditions.  
b. To remove the filter,  
c. Wash the filter with clean water then dry.  
d. Re-install the filter.  
2. Cabinet  
a. Dust cabinet with an oil-free cloth, or using a damp cloth.  
b. Vacuum grill using brush attachment.  
3. Water Bucket  
a. Clean bucket with warm water and detergent.  
Download from Www.Somanual6s.com. All Manuals Search And Download.  
Before calling for service, review this list. It may save you time and expense. This  
list includes common occurrences that are not the result of defective workman-  
ship or materials in this appliance.  
Avoid Service Checklist  
OCCURRENCE  
SOLUTION  
DEHUM IDIFIER DOES NOT OPERATE.  
Plug is disconnected from outlet. Push plug firmly into wall outlet.  
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit  
breaker.  
The dryness level you selected has been reached. Dehumidifier automatically shuts off when  
selected amount of moisture has been removed from the air. If you want to remove more  
moisture, rotate the knob until it points to the CONTINUOUS setting.  
control to the desired setting.  
Bucket not installed properly. See “ Removing Collected Water.”  
Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this  
occurs. Empty bucket and return bucket to position.  
Dehumidifier is not turned on. rotate the knob to " CONTINUOUS " .  
DEHUM IDIFIER RRUNS TOO M UCH.  
Windows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside.  
Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate.  
Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of  
vacuum cleaner to clean grill. See “ Care and Cleaning.” Dehumidifier must be placed in a space  
that does not restrict air flowing into the rear coil or out of the front grill.  
Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the  
longer the dehumidifier will operate.  
DEHUM IDIFIER IS OPERATUING BUT  
ROOM IS NOT DRY ENOUGH.  
Humidity setting is too high. rotate the knob to a lower setting.  
Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the  
longer it takes for the room air to become dry.  
Dehumidifier does not have sufficient clearance to operate. Air flow to front grill is blocked. See  
“ Selecting a Location.”  
Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below  
41°F (5°C). See “ Operating Conditions.”  
Refer to causes under DEHUMIDIFIER RUNS TOO MUCH.  
FROST APPEARS OON COILS ABOVE  
BUCKET OR DRIP TRAY.  
Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the  
coil. Frost will usually disappear within 60 minutes.  
Room Temperature is too low. All models will operate satisfactorily at temperatures greater than  
41°F (5°C).  
NOISE IS LIKE A FAN.  
Air is moving through the dehumidifier. This is a normal sound.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Compaq Computer Hardware 370 User Manual
Craftsman Air Compressor 919167461 User Manual
Craftsman Pressure Washer 919762000 User Manual
Creda Electric Pressure Cooker X153E User Manual
Curtis CD Player CD156 User Manual
CyberData Stereo Amplifier 010861 930106A User Manual
Edimax Technology Network Router AR 7024Um User Manual
Electro Voice Microphone 719KK User Manual
Frigidaire Dishwasher 154768501 User Manual
Generac Power Systems Portable Generator Transfer Switches and Accessories User Manual