Generac Power Systems Portable Generator Transfer Switches and Accessories User Manual |
standby
Generators
p r o d u c t c ata lo g
residential
commercial
liGht
industrial
portable Generators
automatic standby Generators
transfer switches and accessories
Download from Www.Somanuals.com. All Manuals Search And Download.
How MucH Power do you need?
tranSfer SwitcH
confiGurationS
1
2
3
6
7
8
4
5
9
10
automatic transfer Switch basic
Whole-House Protection
Generac offers air-cooled and liquid-cooled generators that can supply up to
whole-house protection. in conjunction with a transfer switch, this application
completes your power solution package (see page 8 for options).
rtS-e models
to accurately size liquid-cooled generators, a licensed electrician should apply
an amp meter to the circuits and appliances to determine the load requirement
for back up.
2
0
0
M
A
A
M
P
C
LO
A
A
D
N
SHEDDING
SF TC
AUT
O
T
I
T
R
E
R
S
W
I
H
U
N
T
E
I
L
M
I
T
A
Y
3
S
R
E
-
R
I
V
N
I
D
C
O
E
O
D
R
I
S
C
O
N
N
E
C
T
I
N
S
I
D
E
/
O
U
T
D
O
O
R
R
A
T
E
D
Sizing Guide
Air Cooled Generator
5-Ton Central Air 1
4-Ton Central Air 1
3-Ton Central Air 1
Well Pump or Water Heater
Family Room
8 kW 10 kW 14 kW 17 kW
Circuits
20 kW
rtS-S models
(50 Amp / 240V)2
(40 Amp / 240V)2
(30 Amp / 240V)2
(20 Amp / 240V)2
(20 Amp / 120V)
(20 Amp / 120V)
(20 Amp / 120V)
(20 Amp / 120V)
(20 Amp / 120V)
(20 Amp / 120V)
(15 Amp / 120V)
(15 Amp / 120V)
(15 Amp / 120V)
(15 Amp / 120V)
(15 Amp / 120V)
(15 Amp / 120V)
(15 Amp / 120V)
•
Master Bedroom
Home Office
rtS-n models
Media Room
automatic transfer switch basic is rated
nema 1. all rts-n, rts-e & rts-s
transfer switches are nema 3r (outdoor/
indoor) rated.
Garage
Kitchen (#1)3
Kitchen (#2)3
Bathroom
Furnace
note: warranty coverage is not
available for generators that are
used for prime power (main power
source) in place of the existing
utility power where utility power is
present or in place of utility power
where utility power service does
not normally exist. for life support
or critical care applications, please
see page 6 for industrial units.
Sump Pump
Bedroom (#2)
Bedroom (#3)
Bathroom (#2)
1 check your air conditioner’s starting requirements. starting requirements for older and/or less efficient equipment may exceed
recommended generator capability. additionally, for any electrical equipment or appliances, always check the manufacturer’s
power requirements. this will help to ensure standby power accommodations for items that cycle during operation.
2 240 volt appliances require 2 circuits 3 most kitchens require multiple circuits
for smaller central air up to 2 tons
•
note: rooms and appliances indicated here are for example only. you may choose others that better reflect your needs. because of the
cycling nature of some appliances such as refrigerators and furnaces, it may not be possible for all appliances to run simultaneously.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
air-cooled 8 – 20 kw
GENErAC AIr-COOLED MODELS
America’s #1 selling home standby generator
Generac air-cooled models feature Generac’s ohVi industrial
engines for reliability and long life, and plateau honing to
significantly decrease service intervals.
8-17 kW
8 kW / 10 kW / 14 kW / 17 kW MODELS (STEEL)
Air-cooled models for essential circuit protection
smaller air-cooled models provide essential circuit
protection for small to medium sized homes.
Engine horsepower strength:
Generac ohVi® (overhead
Valve industrial) engines
continuous Fuel: all models run on lp gas or natural
•
are specifically designed for
generator demands. the 2-year
oil change interval, full-pressure
lubrication system and spin-on
oil filter contribute to the longest
running engine in the industry.
gas, providing continuous power with reduced emissions.
circuit coverage: individual models can protect
8, 10, 12, 14, or 16 circuits in your home.
•
true power™ technology for sensitive electronics:
10-17 kw units feature an electronic governor for smooth and consistent output with less
than 5% total harmonic distortion for sensitive electronic equipment and appliances.
•
Steel Enclosures: all steel enclosures feature durable galvanneal finish which bonds
zinc to steel for superior rust and corrosion protection.
•
Composite Mounting Pad: provides for easier installation.
•
ul listed: ul 2200 listing ensures the generator meets local building code approval,
safety and certified kw power ratings.
•
External dual gFcI outlet: easy access to power for outdoor equipment available on
17 kw model.
•
17-20 kW
17 kW AND 20 kW MODELS (ALUMINUM)
Control Panel for
The quietest and most powerful air-cooled
protection on the market
10 - 20 kW air-cooled generators
the easy-to-use control panel
features user-friendly lcd digital
controls, providing bilingual plain
text display.
these larger air-cooled models are the quietest and most
powerful generators of their size on the market today. the
20 kw model includes the base fascia for a finished look
and thorough protection from debris and rodents. they
include all the features of the 8-17 kw models above as
well as the following:
Quiet-test™: the patented Quiet-test low-speed
exercise mode for up to 50% quieter weekly self-test.
•
Increased circuit coverage: the 20 kw model
provides up to whole-house protection.
•
aluminum all-Weather Enclosures: all-weather corrosion resistant
aluminum enclosures prolong the life and look of the generator. ideal for
salt air coastal communities.
•
External dual gFcI outlet: easy access to power for outdoor equipment.
•
4
Download from Www.Somanuals.com. All Manuals Search And Download.
liquid-cooled 22 – 150 kw
QT SErIES
The quiet standard in liquid-cooled
automatic standby power
Quiet-Test™ feature:
Generac’s Qt series generators have redefined backup
power for larger residential and commercial applications.
these models feature automotive grade liquid-cooled
engines for proven power and performance.
reduces noise by lowering engine
speed during the generator’s
weekly self-test cycle. the ultra-
quiet sound level is comparable
to a car at idle, up to 50% quieter
With outputs ranging from 22 to 150 kW, these QT models feature:
than when the generator is
operating under normal load.
• Quiet-Test™: all models feature the patented Quiet-test low-speed exercise mode
for quieter weekly self-test.
• Durable Enclosures:
–
Steel enclosures have a galvanneal paint finish which bonds zinc to steel
for superior rust and corrosion protection.
–
Aluminum enclosures are corrosion resistant and ideal for salt air
coastal conditions.
• Continuous Fuel: all models run on lp gas or natural gas, providing continuous
fuel and reduced emissions.
r-Series Controller for
22-60 kW Liquid-cooled
generators
full system monitoring including
led indicators for safety
shutdowns, fuel pressure and
battery voltage. integrated
transfer switch controller for rts
transfer switch.
• Stable Output: clean, consistent power for sensitive electronics. ul listed.
• Transfer Switches: matching transfer switches sold separately. rated from 100 to
800 amps. see page 8.
22-60 kW
22 kW – 60 kW MODELS
ideal for many large residential and commercial
applications. a perfect size for small office
buildings, churches, municipal buildings,
retail centers, police stations, schools, farms,
convenience stores and restaurants.
H-100 Controller for 70 kW
and above Liquid-cooled
generators:
offers quick access and
simultaneous monitoring of key
generator functions. integrated
transfer switch controller for
hts transfer switch.
70-150 kW
70 kW – 150 kW MODELS
a superior solution for applications that require more
sophisticated monitoring and diagnostic capabilities.
applications range from supermarkets and pumping
stations to strip malls and hotels.
ADvANTAGES Of GASEOUS fUEL
natural gas is delivered reliably
and continuously underground.
natural gas demand drops
significantly during a power
outage, assuring more than
adequate supply.
spark-ignited engines start more
easily than diesel engines in cold
climates. spark-ignited engines
are also quieter in terms of noise,
vibration and harshness.
Gaseous fueled engines emit fewer
pollutants than other fuels and are
more environmentally friendly.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Modular Power SySteMS • GeMini • Bi-Fuel
GEMINI® TWIN PACk
fOr HIGHEST POWEr
DENSITy
INDUSTrIAL POWEr frOM GENErAC’S
MODULAr POWEr SySTEMS
for applications requiring greater amounts of standby
when space is at a premium and
power, the mQt100 and mQt150 models are ideal.
reliability is critical, no other
available through your local Generac industrial
dealer, the output of these gensets can be combined
to form a Generac modular power system (mps).
mQt series modular power systems are building
manufacturer comes close to
Generac’s Gemini twin pack.
part of the mps family, these units
feature two 500 kw generators inside
blocks that link together to combine the power output
a single, weather resistant and sound
equal to one large single generator. with the ability to
attenuated enclosure. the exclusive
parallel up to ten 100 kw units or up to ten 150 kw
units, these generators can satisfy higher end
requirements ranging from 100 to 1500 kw.
powermanager™ control system
allows for combining the output of
large, single engine gensets with a
significant improvement in reliability.
• Smaller footprint than many
comparable single engine models
redundancy
because each mQt generator within the system backs up the others, critical loads receive
extra protection and building managers enjoy greater peace of mind.
• Built-in redundancy for superior
system reliability
• Scalable solution – up to seven
Gemini gensets can be paralleled
without additional switchgear for
up to 7,000 kw in total output
Serviceability
mQt generators use modified high volume truck or industrial engines that can be serviced
using readily available, cost-effective parts. since each generator backs up the others,
servicing can be accomplished without losing backup power to critical loads.
• Fast production turn around –
often within weeks
Scalability
a Generac modular power system can be expanded as facilities grow. there is no need
to replace the system if future power requirements exceed projections and no need to
over-spend on a larger system that might never be fully utilized.
• Easily serviced with common parts
Flexibility
mps modules provide unmatched flexibility because they can be placed in any configuration
side by side, end to end, together or apart. they are light enough for most rooftop
applications and the lower weight eliminates the need for heavy-duty cranes and material
handlers during installation.
THE GENErAC
INDUSTrIAL DEALEr
NETWOrk
BI-fUEL™
installation, start-up and servicing of
modular power systems require
specialized knowledge and expertise.
Generac industrial dealers have
factory-trained personnel to ensure
that your customers get the best
possible solution, fast delivery,
Longest run Times in the Industry
Generac bi-fuel generators start on diesel fuel and add natural gas as load is applied.
during an outage, they typically operate on a mixture of up to 70% natural gas and
30% diesel fuel (contact factory for product specifications). if the natural gas supply is
interrupted, the generator automatically switches to 100% diesel without any power drop
during the transition.
professional installation and start-up.
Benefits of Bi-fuel
if a customer needs a diesel-powered
generator or a generator size that is
beyond the scope of the Qt series
line, a Generac industrial dealer can
meet requirements up to 9,000 kw.
• Dramatically increased run times
• Minimal on-site fuel storage
• Reduced fuel maintenance
• Reduced environmental risk
• Lower particulate and NOx emissions
Generac industrial dealer certified
service technicians are fully trained
on all Qt series generators and
can provide your customers with
hassle-free maintenance and
service agreements.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Portable 1800 – 17500 wattS
Better power. More choices.
from home use to camping, construction or outdoor events, Generac portable generators
provide dependable portable power. power the fun stuff or cover an emergency. the wide
range of sizes gives you flexibility to choose as much power as you need.
• Generac OHVI® Engine*: Generac’s
original and proven overhead Valve
industrial engines provide the longest
running time in the industry.
• Steel Fuel Tank: includes incorporated
fuel gauge.
• Low-Tone Muffler: provides quiet
operation.
• Electric Start*: includes starting battery.
• Fold-Down Handles: provide easy
portability.
• Never-Flat Wheels: provide all-terrain
portability.
* see specs for available models.
• Hour Meter*: tracks usage and includes
maintenance resets.
XP SerieS
xp series
xP SErIES: 4000 — 10000 WATTS
the professional grade Xp series of portable generators has been engineered for high
performance. durable construction with oversized full wrap frame tubing and impact
resistant corners minimizes damage from rough handling. these rugged units also include:
• true Power™ technology for utility quality
electrical output for sensitive electronics
• external battery charge Jack on
electric start models
• low-oil Pressure Protection to protect
engine from damage
• circuit breaker outlet Protection
including dual breakers on
120/240V outlets
• covered outlets for more protection from the
environment
• cord Set included 25’/30 amp
• Start/Stop fuel Shut-off and choke controls • Maintenance kit included
conveniently located on outlet panel
GP SerieS
gp series
GP SErIES: 1800 — 17500 WATTS
gp 1800 —8000 Watts
easy to use in a variety of applications, our Gp series of portable
generators offers affordable reliability. features include:
• Hardened Steel tube cradle for durability
• low-oil Shutdown shuts engine down when oil runs low and prevents
serious damage
• circuit breaker Protected outlets for circuit protection
• Hour Meter with maintenance resets (excludes Gp1800 and Gp3250)
gp 15000E — 17500E Watts
two of the most powerful portable generators on the
market offer exceptional value:
• 16-Gallon fuel tank provides extended run time
• idle control increases fuel efficiency
• included accessories wheel kit and lifting eye
7
Download from Www.Somanuals.com. All Manuals Search And Download.
autoMatic tranSfer SwitcHeS
POWErMASTEr™
LOAD SHEDDING
DEvICE
transfer switches
AUTOMATIC TrANSfEr SWITCHES
as a part of the generator system, the transfer switch transfers the electrical load onto the
generator when power fails. when utility voltage returns, the transfer switch safely returns
circuit coverage back to the utility.
create priority loads to ensure
home comfort during a power
loss! the powermaster is a load
shedding device that allows
a home owner to operate two
large electrical loads instead
of only one large appliance.
examples of this include a
central air conditioner or an
electrical hot water heater. when
the priority load is running,
the powermaster will lock out
the other piece of equipment,
keeping it from turning on until
the demand is satisfied for the
priority load. after the demand is
satisfied, the powermaster allows
the secondary load to come
online and operate.
Distributed Load Center
Generac offers three models of automatic transfer switches for homeowners who
choose to back up selected circuits rather than the entire house. pre-wired load
center models are available with a choice of 8, 10, 12, 14 or 16-circuits.
Generac makes installation easy and inexpensive.
all distributed load center models include:
• 30 ft. pre-wired conduit for connecting the transfer
switch to the external connection box
• 2 ft. pre-wired conduit for moving circuits from
the main panel to the transfer switch
• Pre-wired external connection box with a weather-proof
conduit for generator connections
PowerManager™ Load Shedding Transfer Switch
the powermanager lts is designed to allow the most efficient use of the generator by
monitoring and managing the backed up selected and non-selected circuits.
if the generator approaches overload condition, the non-selected circuits are
cycled off, allowing the selected circuits to remain powered. this switch is
designed to operate with the digital controls that are used on single-phase
air-cooled and liquid-cooled generators from 17 kw through 48 kw.
• Housed in an aluminum NEMA 3R, outdoor rated enclosure
for use with units
• Service entrance rated at 200 Amps with built-in 16 circuit
priority load center
up to 60 kW
• Main contactor protects the selected priority circuits while the
secondary contactor protects the remaining, non-selected
circuits located in the existing electrical panel
• Cover is side hinged for easy access
RTS Transfer Switches
rts transfer switches are designed for a wide variety of applications that
require up to 400 amps. the rts is integrated with the r-series digital
controller and operates only with standby generators thru 60 kw.
nema 3r (outdoor rated) enclosures are standard.
RTS-N (Single and Three-Phase)
use rts-n models for custom installations or with
applications that require a sub-panel.
• 100, 200, or 400 Amp
RTS-E with Service Disconnect (Single-Phase)
use rts-e models with service disconnect for quick and
easy installations.
• 100, 200, or 400 Amp
• Service-entrance rated and UL Listed (U.S. only)
(shown without cover)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
autoMatic tranSfer SwitcHeS
™
THE GENrEADy™ LOAD CENTEr –
EZ TrANSfEr
OPErATOr™
The future in generator installation
the eZ transfer operator was
developed by Generac to
the Genready load center simplifies the generator system
and installation and maximizes customer savings. in addition,
advanced engineering creates the easiest and most cost-effective
installation of any home standby generator on the market. new home
construction, or renovations requiring electrical upgrades, are the
opportune time to install a Genready load center and a Generac
automatic home standby generator.
install into the Genready load
center. when installed with
a generator, it automatically
transfers the protected circuits
from utility to generator power
during a power outage. when
utility is restored, the eZ
with a traditional generator installation, three boxes are required:
the main circuit panel, the automatic transfer switch, and the
emergency circuit panel.
transfer operator returns the
circuits back to utility power.
the Genready load center replaces the main circuit panel and
incorporates an automatic transfer switch so all power switching is
handled within one unit. it becomes a hybrid panel capable of separating out only the
electrical circuits the homeowner chooses to back up during a power outage.
Features include:
• 40 circuit capacity with the use of tandem breakers
• Dimensions same as a standard 42-circuit main load center
• Utilizes standard Siemens Load components
• Compatible with generators rated up to 125 Amps/30 kW
• Single-Phase applications only
TM
Traditional Installation
Genready™ Installation
B U I L D E R
Alliance
program
200 Amp
BUILDErS –
Join the Generac Builder
Alliance and get cash back
for generator purchases
Automatic
Transfer
Switch
Emergency
Load
Center
Main Load
Center
42-Space
offer your new home customers
the safety and comfort of
GenReady Installation Levels
Basic Advanced Complete
automatic standby power and
increase your profits at the same
time. starting from the first unit
you buy, Generac will give you
cash back for your generator
purchases. in addition to the profit
earned from each sale, you will
receive cash rebates for product
purchased through your indicated
builder alliance partner(s).
The innovative GenReady load center combines
three boxes into one, saving space and money on
generator installations!
HTS TrANSfEr SWITCHES
(Single-Phase and Three-Phase)
hts transfer switches, designed for simple monitoring,
operation and maintenance, are constructed to ensure superior
performance. the hts is part of an integrated system and
operates only with Generac commercial-series generators
(70-150 kw) with the h-100 controller. all switch components are
front adjustable and removable for programming and servicing.
Program Benefits:
as a builder, when you join the
program you will receive:
• 200 New Home Owner
brochures
• Marketing support cd
recoMMended
SwitcH
recoMMended
SwitcH
• Factory contact information
and sales tools
Model
Model
Qt022 ........................rts 100
Qt025 ........................rts 100
Qt027 ................ rts 100-200
Qt030 ................ rts 100-200
Qt035 ................ rts 100-200
Qt045 ................ rts 100-200
Qt060 ................ rts 100-400
Qt070 ................hts 100-400
Qt080 ................hts 150-400
Qt100 ...............hts 200-600
Qt130 ................hts 200-600
Qt150 ................hts 300-800
• Information on installation
training for your electrical
contractor
Visit builder.generac.com to join.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
acceSSorieS
remote Wireless Monitor for
Air-Cooled Generators
add efficiency by allowing for remote
viewing of generator status and
parameters from inside the home.
fascia for Air-Cooled Units
complement the contoured enclosure with a fascia base wrap
that snaps together around the bottom of the generator. fits
air-cooled generators manufactured after april 2008 that have
the contoured body wrap style. fascia continues the sleek,
contoured appearance as well as offering
protection from rodents and insects by
covering the lifting holes located
Scheduled
in the base. available in grey
only. standard on
20 kw air-cooled model.
Maintenance kits
a scheduled maintenance
program will ensure that your
system is always in top operating
condition and that your warranty
requirements are met. Generac
offers a comprehensive line of
scheduled maintenance kits to ensure long life and top
performance of your generator system.
Air-Cooled Generator Transport Cart
moving a 400 lb generator can be
hard work. the Generator transport
cart will assist with moving the
generator from the truck to the
planned installation site. allows for
a single person to easily maneuver
any air-cooled product to the desired
installation location.
Cold Weather kit
the cold weather kits are
recommended for areas where the
temperature drops below 30° f.
ACCESSOrIES
Air-Cooled Remote Monitoring Options*
Model Description
Air-Cooled Cold Weather Kit
Model Description
Contents
5636
Remote wireless monitor
5634
For air-cooled units mfg prior to 4/08 Battery wrap with internal thermostat
Liquid-Cooled Remote Monitoring Options
70 kW and above
5635
For air-cooled units mfg after 4/08
Battery wrap with internal thermostat
Liquid-Cooled Cold Weather Kit
Model Description
Model Description
Contents
5464
5465
5466
Remote annunciator panel with 8 relays
5629
5630
5631
5632
5633
For 1.6L engines
28” Battery warmer w/oil filter
Remote annunciator panel without LEDs
and keypad (relays only)
For 2.4L engines
28" Battery warmer, zip ties, thermostat
44" Battery warmer, zip ties, thermostat
44" Battery warmer, zip ties, thermostat
44" Battery warmer, zip ties, thermostat & gear oil
Remote annunciator panel without relays
For 4.2L engines
Air-Cooled Scheduled Maintenance Kit
Model Description
For 3.0, 4.6, 6.8 direct drive units
For 6.8L gear drive units
5661
5662
5663
7 kW, 410 cc kit
8 kW, 410 cc kit
10 kW, 530 cc kit
Liquid-Cooled Extreme Cold Weather Kit
Model Description
Use with cold
weather kit #
Contents
12,13, 14,15, 16 kW, 17 & 18 kW,
760/990 cc kit
5664
5665
18 kW (3600 rpm), 20,
5615
Block heater & mounting hardware
Block heater & mounting hardware
5629
25, 30 kW (1.6L)
20 kW, 999 cc kit
5616
5618
5617
5619
5620
5667
25 kW (1800 rpm), 45 kW (2.4L)
5630
5631
5632
5633
5634
5635
Miscellaneous
Liquid-Cooled Scheduled Maintenance Kit
Model Description
35 & 45 kW - both 1800 RPM (4.2L) Block heater & mounting hardware
Model Description
60 kW (3.0L)
Block heater & mounting hardware
Block heater & mounting hardware
Block heater & mounting hardware
Block heater & mounting hardware
18 kW low speed aluminum, 20, 25 &
5655
5651 Base plug for all liquid-cooled models
5652 Base plug for all air-cooled models mfg prior to 4/08
5654 Grey paint kit – Units mfg prior to 4/08
5653 Tan paint kit – Units mfg prior 4/08
5703 Bisque paint kit – Units mfg after 4/08
5704 Medium grey paint kit – Units mfg after 4/08
5685 Air-cooled generator transport cart
5666 Fascia for air-cooled units mfg after 4/08
80 kW (4.6L)
30 kW steel, 3600 RPM units, 1.6L units
25 kW low speed aluminum & 45 kW
5656
70, 100, 130 kW (6.8L)
150 kW (6.8L)
steel, 3600 RPM units, 2.4L units
5657
5658
60 kW unit, 3.0L units
Load Management Options
Model Description
35 & 45 kW low speed, aluminum,
4.2L units
Contents
Use with
5239
5621
PowerMaster load shedding device
Auxiliary transfer switch contact kit
PowerMaster
60 kW & below
R-style switch
5659
5660
80 kW, 4.6L kit units
Contact, screws & washers
70, 100, 130, 150 kW, 6.8L units
* For use with 10-20 kW air-cooled generators manufactured after April 2008.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
TrANSfEr SWITCHES
5499
GenReady w/ EZ
Transfer Operator
RTSS200A3
Load Shedding
5447
EZ Transfer Operator
5488
GenReady
Model
RTSD100A1
RTSF100A1
RTSH100A1
RTSP100A1
RTSW100A1
Amp Rating
100
100
100
100
100
200
N/A
200/125
200/125
40
Number of Circuits
8
10
12
14
16
16 Priority
N/A
40
1 x 50 Amp, 2 pole
1 x 40 Amp, 2 pole
1 x 20 Amp, 2 pole
4 x 20 Amp, 1 pole
4 x 15 Amp, 1 pole
1 x 50 Amp, 2 pole
1 x 40 Amp, 2 pole
1 x 20 Amp, 2 pole
5 x 20 Amp, 1 pole
5 x 15 Amp, 1 pole
1 x 50 Amp, 2 pole
1 x 40 Amp, 2 pole
1 x 20 Amp, 2 pole
5 x 20 Amp, 1 pole
5 x 15 Amp, 1 pole
1 x 30 Amp, 2 pole
1 x 20 Amp, 2 pole
3 x 20 Amp, 1 pole
3 x 15 Amp, 1 pole
1 x 40 Amp, 2 pole
1 x 30 Amp, 2 pole
3 x 20 Amp, 1 pole
5 x 15 Amp, 1 pole
1 x 30 Amp, 2 pole
1 x 20 Amp, 1 pole
5 x 15 Amp, 1 pole
Breakers
N/A
N/A
N/A
Load Transition Type
Voltage
Open
120/240
Single
Open
120/240
Single
Open
120/240
Single
Open
120/240
Single
Open
120/240
Single
Open
120/240
Open
N/A
N/A
N/A
N/A
3.5
N/A
120/240
Single
Open
120/240
Single
Phase
Single
Enclosure Type
Dimensions (H” x W” x D”)
Weight (lbs)
NEMA 1
29.5 x 12.1 x 6.8
62
NEMA 1
29.5 x 12.1 x 6.8
72
NEMA 1
29.5 x 12.1 x 6.8
76
NEMA 1
29.5 x 12.1 x 6.8
78
NEMA 1
29.5 x 12.1 x 6.8
80
NEMA 1R, 3R
42.5 x 21 x 8.25
80
NEMA 1
42 x 15 x 4
45.5
NEMA 1
42 x 15 x 4
49
Model
HTSN100A
HTSN100G
100
HTSN100J
100
HTSN100K
100
HTSN150A
150
HTSN150G
150
HTSN150K
HTSN200A
HTSN200G
200
HTSN200J
200
HTSN200K
200
HTSN300A
300
HTSN300G
300
HTSN300J
HTSN300K
300
Amp Rating
Load Transition Type
Voltage
100
Open
150
Open
200
Open
300
Open
Open
Open
120/240
Three
Open
277/480
Three
Open
Open
120/208
Three
Open
120/208
Three
Open
Open
Open
Open
Open
120/240
Single
120/208
Three
120/240
Single
277/480
Three
120/240
Single
120/240
Three
277/480
Three
120/240
Single
120/208
Three
120/240
Three
277/480
Three
Phase
Enclosure Type
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
Dimensions
(H” x W” x D”)
36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 48 x 30 x 12 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 48 x 30 x 12
Weight (lbs)
NEMA 1 / NEMA 3R
86 / 112
86 / 112
86 / 112
105 / 131
86 / 112
89 / 115
105 / 131
86 / 112
89 / 115
89 / 115
105 / 131
101 / 127
108 / 134
108 / 134
124 / 150
Model
HTSN400A
400
HTSN400G
HTSN400J
400
HTSN400K
400
HTSN600A
HTSN600G
600
HTSN600J
HTSN600K
HTSN800A
800
HTSN800G
HTSN800K
800
Amp Rating
Load Transition Type
Voltage
400
Open
600
Open
600
Open
600
Open
800
Open
Open
Open
Open
Open
Open
Open
120/240
Single
120/208
Three
120/240
Three
277/480
Three
120/240
Single
120/208
Three
120/240
Three
277/480
Three
120/240
Single
120/208
Three
277/480
Three
Phase
Enclosure Type
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 1/3R
NEMA 12/3R
NEMA 12/3R
NEMA 12/3R
NEMA 12/3R
NEMA 12/3R
NEMA 12/3R
NEMA 12/3R
Dimensions
(H” x W” x D”)
36 x 24 x 10
101 / 127
N/A
36 x 24 x 10
101 / 127
N/A
36 x 24 x 10
101 / 127
N/A
48 x 30 x 12
124 / 150
N/A
60 x 36 x 20
N/A
60 x 36 x 20
N/A
60 x 36 x 20
N/A
60 x 36 x 20
N/A
60 x 36 x 20
N/A
60 x 36 x 20
N/A
60 x 36 x 20
N/A
Weight (lbs)
NEMA 1/ NEMA 3R
Weight (lbs)
NEMA 12/NEMA 3R
650 / 650
650 / 650
650 / 650
650 / 650
680 / 680
680 / 680
680 / 680
RTSN400G3
RTSN400J3
400
Model
RTSN100A3 RTSE100A3 RTSN100G3
RTSN100K3
RTSN100J3 RTSN200A3 RTSE200A3 RTSN200G3 RTSN200J3
RTSN200K3
200
RTSN400A3
400
RTSE400A3
Amp Rating
100
100
100
100
100
200
200
200
200
400
400
Open w/
Service
Open w/
Service
Open w/
Service
Load Transition Type
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
Disconnect
Disconnect
Disconnect
Voltage
120/240
Single
120/240
Single
120/208
Three
277/480
Three
120/240
Three
120/240
Single
120/240
Single
120/208
Three
120/240
Three
277/480
Three
120/240
Single
120/240
Single
120/208
Three
120/240
Three
Phase
Enclosure Type
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
Dimensions
(H” x W” x D”)
20 x 15.2 x 7.3 20 x 15.2 x 7.3 24 x 20.5 x 7.3 36 x 24.5 x 10.2 24 x 20.5 x 7.3 20 x 15 x 7.3 30 x 16.5 x 7.3 24 x 20.5 x 7.3 24 x 20.5 x 7.3 48 x 30.6 x 13.3 36.1 x 24.4 x 10.2 40 x 31 x 10.5 36.1 x 24.4 x 10.2 36.1 x 24.4 x 10.2
35 52 49 95 95 35 58 49 49 105 88 134 107 107
Weight (lbs)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications
Product Specifications
air-Cooled
liquid-Cooled
Series 3
QT02224
22 kW
22 kW
91.6
QT02516
25 kW
24 kW
104.2
86.8
QT02724
27 kW
25 kW
112.5
94
QT03016
30 kW
29 kW
120.8
104.2
N/A
QT03624
36 kW
35 kW
150
QT04524*
45 kW
45 kW
187.5
QT04842*
48 kW
45 kW
200
QT06024
60 kW
60 kW
250
QT07068
70 kW
68 kW
291.6
QT08046
80 kW
78 kW
333.3
QT10068*
100 kW
97 kW
QT13068
130 kW
130 kW
541.6
QT15068
150 kW
150 kW
625
Model
05526
8/7 kW
120/240V
33.3
05528
10/9 kW
120/240V
41.6
05530
14/13 kW
120/240V
58.3
05531
17/16 kW
120/240V
70.8
05532
17/16 kW
120/240V
70.8
05533
20/18 kW
120/240V
83.3
Rated Power (LPG/NG)
Voltage (Single-Phase)
Amps @ 240V LPG
Amps @ 240V NG
Engine/Alternator RPM
Engine
Rated Power LP
Rated Power NG
Amps @ 240V, 1 Ø LP
Amps @ 208V, 3 Ø LP
Amps @ 240V, 3 Ø LP1
Amps @ 480V, 3 Ø LP
Engine/Alternator RPM
Engine Size
416.6
29.2
37.5
54.2
66.6
66.6
75
76
125
156.3
167
208.4
180.6
90.3
243.1
277.9
347.3
451.5
521
3600/3600
OHVI / 410cc
62 (1.68)
140
3600/3600
OHVI / 530cc
70 (1.93)
156
3600/3600
OHVI / 992cc
84 (2.30)
220
3600/3600
OHVI / 992cc
94 (2.57)
261
3600/3600
OHVI / 992cc
94 (2.57)
262
3600/3600
OHVI / 999cc
106 (2.90)
294
N/A
N/A
N/A
108
135.4
144
210.7
240.8
301
391.3
451.5
N/A
N/A
N/A
N/A
54
67.7
72
105.3
120.4
150.5
195.6
225.7
Fuel Consumption LPG
Fuel Consumption NG
Quiet-Test Low Speed Exercise
db(A) at Exercise
1800/1800
2.4L
3600/3600
1.6L
1800/1800
2.4L
3600/3600
1.6L
1800/1800
2.4L
3600/3600
2.4L
1800/1800
4.2L
3600/3600
2.4L
1800/1800
6.8L
3600/3600
4.6L
2300/1800
6.8L
3000/1800
6.8L
3600/3600
6.8L
No
No
No
Yes
Yes
Yes
Cylinder Arrangement
Fuel Consumption LPG
Fuel Consumption NG
Quiet-Test Low Speed Mode
db(A) at Exercise
In-line 4
120 (3.3)
316
In-line 4
175 (4.81)
437
In-line 4
149 (4.1)
359
In-line 4
209 (5.7)
525
In-line 4
199 (5.4)
480
In-line 4
286 (7.86)
720
V-6
In-line 4
332 (9.0)
862
V-10
V-8
V-10
V-10
V-10
62
63
66
60
60
60
261 (7.2)
661
411 (11.3)
1020
465 (12.78)
1154
507 (13.9)
1260
719.8 (19.56)
1786
830.6 (22.6)
2061
db(A) at Normal Operating Load
Enclosure
62
63
66
66
66
66
Steel
Steel
Steel
Steel
Aluminum
Gray
Aluminum
Gray
Enclosure Color
Bisque
Bisque
Bisque
Bisque
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Dimensions (L” x W” x H”)
Generator Weight (lbs.)
48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25
336 375 425.5 445 414 451
61
62
61
62
58
61
60
63
61
64
61
65
66
db(A) at Normal Operating Load
Transfer Switch Type Needed
Enclosure Material
70
74
70
75
64
73
65
71
65
74
72
75
79
RTS
RTS
RTS
RTS
RTS
RTS
RTS
RTS
HTS
HTS
HTS
HTS
HTS
Aluminum
Gray
Steel
Aluminum
Gray
Steel
Aluminum
Bisque
77 x 33.5 x 45
N/A
Steel
Aluminum
Gray
Steel
Steel or Alum
Tan
Steel or Alum
Tan
Steel or Alum
Tan
Steel or Alum
Tan
Steel or Alum
Tan
Enclosure Color
Bisque
62.2 x 29 x 33.5
875
Bisque
62.2 x 29 x 33.5
935
Bisque
77 x 33.5 x 45
1414/14642
Tan
Dimensions (L” x W” x H”)
Generator Weight Steel (lbs.)
62.2 x 29 x 33.5
N/A
62.2 x 29 x 33.5
N/A
77 x 33.5 x 45
N/A
89 x 34 x 48
1650
96.5 x 37 x 48
2185
116 x 37 x 55**
2010
116 x 37 x 55**
2705/27552
116 x 37 x 55**
2873
116 x 37 x 55**
2666
Generator Weight Aluminum (lbs.)
843
N/A
891
N/A
1683
N/A
1740/17902
1650
2040
1836
2531/25812
2699
2492
* California emission compliant model. Must specify with
“Y” at end of typecode when ordered.
1 Consult factory for availability
2 California emission compliant model weight
** Height does not include measurement of exhaust stack(s).
*** All specifications subject to change without notice.
3 See product selection guide to customize your generator
portable
GP15000E
GP17500E
XP4000
XP8000E
5606/5712*
8000 Watts
12000 Watts
Generac 410cc OHVI
Yes
XP10000E
Series
GP1800
5723
GP3250
5724
GP5500
5736/5737*
5500 Watts
6875 Watts
389cc OHV
No
GP6500
GP7000
GP7000E
5626
GP8000
GP8000E
5681
GP10000E
5739
Model #
5623/5700*
6500 Watts
8000 Watts
389cc OHV
No
5625
7000 Watts
8750 Watts
Generac 410cc OHVI
Yes
5680
8000 Watts
10000 Watts
Generac 410cc OHVI
Yes
5734
15000 Watts
22500 Watts
Generac 992cc OHVI
Yes
5735
5604/5713*
4000 Watts
5000 Watts
Generac 220cc OHVI
Yes
5607
10000 Watts
15000 Watts
Generac 530cc OHVI
Yes
Running Watts
Starting Watts
Engine Size and Type
Pressure Lube w/Filter
Starting Method
Battery Included
Covered Outlets
1800 Watts
2050 Watts
163cc OHV
No
3250 Watts
3750 Watts
206cc OHV
No
7000 Watts
8750 Watts
Generac 410cc OHVI
Yes
8000 Watts
10000 Watts
Generac 410cc OHVI
Yes
10000 Watts
15000 Watts
Generac 530cc OHVI
Yes
17500 Watts
26250 Watts
Generac 992cc OHVI
Yes
Electric
Yes
Recoil
Recoil
Recoil
Recoil
Recoil
Electric/Recoil
Yes
Recoil
Electric/Recoil
Yes
Electric
Electric
Recoil
Electric/Recoil
Yes
Electric
N/A
N/A
N/A
N/A
N/A
N/A
Yes
Yes
N/A
Yes
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
2x5-20R
GFCI 2x5-20R
2xL5-30R
1xL14-30R
1x14-50R
2x5-20R
GFCI 2x5-20R
2xL5-30R
1xL14-30R
1x14-50R
GFCI 4x5-20R
1xL5-30R
1XL14-30R
1X14-50R
GFCI 4x5-20R
1xL5-30R
1x14-50R
4x5-20R
1xL14-30R
4x5-20R
1xL14-30R
4x5-20R
1xL14-30R
4x5-20R
1xL14-30R
4x5-20R
1xL14-30R
4x5-20R
1xL14-30R
GFCI 4x5-20R
1xL14-20R
GFCI 4x5-20R
1xL14-30R
2x5-20R
4x5-20R
Outlets
1x10A 12Vdc
1x10A 12Vdc
Hour Meter w/ Maintenance Resets
Low-Oil Shutdown
Fuel Tank Type and Size
Run Time at 50%
No
Low Level
Steel, 4.0 Gal
14 Hours
No
No
Low Level
Steel, 4.0 Gal
13.5 Hours
No
Yes
Low Level
Steel, 6.6 Gal
10 Hours
No
Yes
Low Level
Steel, 6.6 Gal
9 Hours
Yes
Low Pressure
Steel, 8.0 Gal
11 Hours
No
Yes
Low Pressure
Steel, 8.0 Gal
11 Hours
No
Yes
Low Pressure
Steel, 8.0 Gal
8 Hours
Yes
Low Pressure
Steel, 8.0 Gal
8 Hours
Yes
Low Pressure
Steel, 10.0 Gal
10 Hours
No
Yes
Low Pressure
Resin, 16.0 Gal
10 Hours
No
Yes
Low Pressure
Resin, 16.0 Gal
10 Hours
No
Yes
Low Pressure
Steel, 5.0 Gal
12 Hours
20' 20A
Yes
Low Pressure
Steel, 8.0 Gal
8 Hours
Yes
Low Pressure
Steel, 10.0 Gal
10 Hours
No
Cord Set Included
No
No
No
20’ 30A
Handles
N/A
Folding
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fixed, D-Style
Yes
Fixed, D-Style
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
Fold Down/Locking
Yes
First Oil Included
Yes
Yes
Maintenance Kit Included
Emission Certified
CSA Certified Model Availability
Warranty
No
No
No
50 States1
No
50 States1
No
No
No
No
No
Yes
Yes
Yes
50 States2
Yes
50 States1
Yes
49 States
1st Quarter 2009
2 Year Limited
49 States
1st Quarter 2009
2 Year Limited
49 States
Yes
49 States
No
49 States
No
49 States
Yes
49 States
No
50 States
No
50 States
No
49 States
Yes
Yes
Yes
Yes
Yes
2 Year Limited
2 Year Limited
2 Year Limited
2 Year Limited
2 Year Limited
2 Year Limited
2 Year Limited
2 Year Limited
2 Year Limited
3 Year Limited
3 Year Limited
3 Year Limited
33.5 x 26.5
x 27.5
33.5 x 26.5
x 27.5
Dimensions (L” x W” x H”)
23.5 x 17 x 17.5
25.5 x 21 x 19
33.5 x 26.5 x 27.5
33.5 x 26.5 x 27.5
33.5 x 26.5 x 27.5
33.5 x 26.5 x 27.5
33.5 x 22 x 27.5
48.5 x 30.75 x 38.5
48.5 x 30.75 x 38.5
29.25 x 23.5 x 26
32.5 x 26 x 29
35 x 28 x 36
Product Weight (lbs.)
Availability
90.5
101.5
180
185
190
195
200
205
300
373
400
195
255
300
4th Quarter 2008
4th Quarter 2008
4th Quarter 2008
Available Now
Available Now
Available Now
Available Now
Available Now
2nd Quarter 2009
1st Quarter 2009
1st Quarter 2009
1st Quarter 2009
Available Now
1st Quarter 2009
* California Emission Model
All portable specifications and models subject to change. Please consult factory for availability.
1 California models available 4th Quarter 2008 2 California models available 1st Quarter 2009
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Generac - life iS better witH Power.
Product Selection Guide
LIQUID-COOLED GENErATOrS
to build a generator and transfer switch, specify each ordering option below.
Generator voltage ratings must match transfer switch voltage.
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 6
kW Ratings
e.g. (45 kW = 045)
Engine
e.g. (5.4L = 54)
Voltage
Fuel
Enclosure
Steel = S
Aluminum = A
Emission/
Catalytic
Converter
120/240 1ø = A
120/208 3ø = G
120/240 3ø = J
277/480 3ø = K
Natural Gas = n
Propane Vapor = V
Field Convertable
to LP = *
No Catalyst = n
1Catalyst & A/F
Ratio = Y
22
25
27
30
36
45
48
60
60
70
80
100
130
150
2.4L @ 1800 RPM
1.6L @ 3600 RPM
2.4L @ 1800 RPM
1.6L @ 3600 RPM
2.4L @ 1800 RPM
2.4L @ 3600 RPM
4.2L @ 1800 RPM
2.4L @ 3600 RPM
2.4L @ 3600 RPM
A,G,J
A,G,J
A,G,J
A,G,J
n*
n*
n*
n*
n*
n*
n*
n
V
n, V
n, V
n, V
n, V
n, V
A
S
A
S
A
S
A
S
S
S, A
S, A
S, A
S, A
S, A
n/A
n/A
n/A
n/A
n/A
n, Y
n, Y
n
n
n
n
n, Y
n, Y
n, Y
ALL
MODELS
bEGin
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
A, G, J, K
WiTH QT
6.8L @ 3600 RPM
4.6L @ 3600 RPM
6.8L @ 2300 RPM Gear Drive
6.8L @ 3000 RPM Gear Drive
6.8L @ 3600 RPM
SAMPLE
Q T
0 6 0
2 4
K
N
S
N
Q T
MODEL nuMbER (Enter on Order Form)
1 = Catalyst & A/F Ratio may not be available for all models. Contact Your Generac representative for more information.
TrANSfEr SWITCHES
STEP 1
Selection Criteria Transfer Switch
STEP 2
STEP 3
Amp Rating
e.g. (200 Amp = 200) 120/240 1ø = A
120/208 3ø = G
STEP 4
Voltage
STEP 5
Switch Type
Normal = n
Enclosure Type3,4
NEMA 1 = 1
R Controller = RTS
H-100 Controller = HTS Service Entrance Rated1 = E
NEMA 3R = 3
NEMA 12 = 4
Load Shedding2 = S
8 cct. Integrated Load Center2 = D
10 cct. Integrated Load Center2 = F
12 cct. Integrated Load Center2 = H
14 cct. Integrated Load Center2 = P
16 cct. Integrated Load Center2 = W
16 cct. Priority Load Center,
120/240 3ø = J
277/480 3ø = K
Load Shedding3 = S
For Standby
Generators
8 - 60 kW
RTS
n, E, D, F, H, P, W, S
100, 200, 400
A, G, J, K
1, 3
For Standby
Generators
70 - 150 kW
HTS
n
100, 150, 200,
400, 600, 800
A, G, J, K
1, 3, 4
2 0 0
G
3
R T S
N
SAMPLE
PRODuCT nuMbER
(Enter on Order Form)
1 = 120/240 1ø, NEMA 3R Only
2 = 200 Amp service entrance rated NEMA 3R
3 = HTS 100 - 400 Amp NEMA 1/3R Only
4 = HTS 600 - 800 Amp NEMA 12/3R Only
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Generac - life iS better witH Power.
Generac – a Powerful History
A TrADITION Of QUALITy AND INNOvATION
for almost 50 years, Generac power systems has led the industry with
innovative design and superior manufacturing. when it comes to
developing products that are both durable and reliable, we stand head and
shoulders above our competition. that’s because our sole focus has been,
and continues to be, standby power. the result of our efforts can be seen in
every inch of our product offerings.
our vertical integration allows us to control the quality, availability and
flow of materials throughout the manufacturing process. we design and
build our own air-cooled engines, alternators, control systems, automatic
transfer switches, enclosures and base tanks (for diesel and bi-fuel™
models). our products are fully integrated as complete power systems and
each genset is factory tested prior to shipment.
because of our ongoing commitment to quality and innovation, Generac is
the name that home and business owners have
come to trust.
COMMITMENT TO SErvICE
Generac is committed to providing our customers with unsurpassed after-
the-sale service support. our nationwide dealer network has factory trained
technicians on staff and maintains large inventories of Generac parts,
components and accessories.
our state-of-the-art training center ensures that Generac service
technicians are always up to date on new product innovations and
improvements. technicians receive comprehensive technical training and
extensive hands-on experience in the installation, repair and maintenance
of Generac products.
Generac’s commitment to service includes scheduled maintenance
programs, warranty assistance and emergency service to ensure that
Generac customers are never left in the dark.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Generac power systems, inc.
highway 59 & hillside rd.
p.o. box 8
waukesha, wi 53187
1-888-Generac
MyGenerac.com
©2008 Generac power systems, inc. all rights reserved.
specifications are subject to change without notice.
bulletin 0170030sby / printed in usa 04.04, rev. 11.08
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Clarion Cassette Player ADZ625 User Manual
Craftsman Lawn Mower 91738514 User Manual
Dynacord Stereo Amplifier D 12 3A User Manual
Dynex Flat Panel Television DX 26L100A13 User Manual
Estate Dishwasher TUD6710 User Manual
Estate Refrigerator LT14EK User Manual
Extron electronic Projector PMK 350 User Manual
Fender Musical Instrument Amplifier B DEC 30 User Manual
Ford Automobile 2008 Expedition User Manual
Frigidaire Refrigerator PLKU1267DS User Manual