Dyna Glo Electric Heater RMC KFA65TDLX RMC KFA120TDLX RMC KFA170TDLX User Manual |
PORTABLE
FORCED AIR HEATERS
“USER’S MANUAL”
LISTED
MODEL : RMC-KFA65TDLX, RMC-KFA120TDLX
RMC-KFA170TDLX
Before the first use of this heater, please read this USER’S MANUAL very
carefully. This USER’S MANUAL has been designed to instruct you as to
the proper manner in which to assemble, maintain, store, and most
importantly, how to operate the heater in a safe and efficient manner.
Please keep this manual for future reference.
CFM HOME PRODUCTS
2695 MEADOWVALE BOULEVARD
MISSISSAUGA, ONTARIO L5N 8A3
1-800-668-5323
4221- 0059-00
06/04 Rev. 00
EDITION 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
3. UNPACKING AND ASSEMBLY
1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX.
NOTE : Save the shipping carton and packing materials for future storage.
RMC-KFA/65TDLX RMC-KFA120TDLX RMC-KFA170TDLX
Wheel
Wheel Bar
No
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Wheel Cap
Front Handle
Handle
Cord Wrap
Screws
Screws(A) and Screws(B)
Bushing
Cotter Pin and Washer
Screws
Hardware Kit Part No :
HW-KFA1001
Figure 2. RMC-KFA120TDLX
Handle
Cord Wrap
Figure 4. RMC-KFA65TDLX MODEL
Screws(A) Screws(B)
Washers
Bushing
Cotter Pins
Wheels
Cord Wrap
Hardware Kit Part No : HW-KFA1008
Wheels Caps
Front Handle
Wheel Axle
Figure 3. RMC-KFA170TDLX
Figure 5. RMC-KFA120TDLX / RMC-KFA170TDLX MODELS
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
2. ASSEMBLY
A. For RMC-KFA65TDLX Model only (See Figure 6,7)
Tools Required
• Medium Phillips Screwdriver
1. Assembling Handle.
1) Align boss on bottom of handle with the 2 holes on
the shell cover as shown in Figure 6
NOTE : Be sure to match the tab in the bottom of the
handle with the slot in housing cover.
2) Insert screws into the holes in the handle and tighten
each screw.
Figure 6. Handle Assembly
2. Assembling Cord Wrap
1) Align 2 boss on the cordwrap with the 2 holes on the
side cover as shown in Figure 7
2) Insert screws into the holes in the cord wrap and
tighten each screw.
B. For RMC-KFA120TDLX/RMC-KFA170TDLX
Models Only.
These models are furnished with wheels, front handle,
handle and cordwrap, Wheels, Handles, Cordwraps and
the mounting hardware are found in the shipping carton.
Figure 7. Cord Wrap Assembly
Figure 8. Wheel and Handle Assembly, RMC-KFA120TDLX/RMC-KFA170TDLX Models Only.
NOTE : Heater should be inspected before each use, and at least annually by a qualitied service person.
Tools Required
• Medium Phillips Screwdriver
• 38" Open or Adjustable Wrench, Use US(Inch) Screws Nuts.
• Long Nose Pliers
4. KEROSENE (1-K)
For optimal performance of this heater, it is strongly suggested that 1-K kerosene be used. 1-K kerosene has
been refined to virtually eliminate contaminants, such as sulpher. Which can cause a rotten egg odor during
the operation of the heater. However, #1 or #2 fuel oil (diesel fuel) may also be used if 1-K kerosene is not
available. Be advised that these fuels do not burn as clean as 1-K kerosene, and care should be taken to
provide more fresh air ventilation to accomodate any added contaminants that may be added to the heated
space.
1. Assembling Wheel & Front Handle
1) Slide one Wheel & Bushing over the Wheel Axle,making sure that the extended hub of the wheel points
towards the wheel points towards the Wheel Support(See Figure 8,Page 6).
2) Slide Flat Washer over Wheel Axle end,past the hole in the axle.
Slide Cotter Pin into the hole in the Wheel axle, and using your pliers bend the legs of the Cotter Pin
until it can not be removed.
3) Slide Wheel Axle through Wheel Support and assemble the Bushing Wheel, Flat Washer and Cotter Pin
as in Steps 1 and 2.
4) Place Wheel Caps on Flat Washers until they snap in place securely.
5) Place Front Handle on shell flange and insert screws through front handle, shell flange and tighten each
screw after each screw is inserted.
KEROSENE SHOULD ONLY BE STORED IN A BLUE CONTAINER THAT IS CLEARLY
MARKED “KEROSENE”. NEVER STORE KEROSENE IN A RED CONTAINER.
Red containers are associated with gasoline.
NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated place outside the
living area.
NEVER use any fuel other than 1-K kerosene (#1 fuel oil is an acceptable substitute.)
NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other oil
compounds in this heater. These are volatile fuels that can cause an explosion or uncontrolled flames.
NEVER store kerosene in direct sunlight or near a source of heat.
2. Assembling Handle & Cord Wrap.
1) Assembling Handle : Assemble by method described above for model RMC-KFA65TDLX.
2) Assembling Cord Wrap : Assemble by method described above for model RMC-KFA65TDLX.
NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time.
“OLD KEROSENE” WILL NOT BURN PROPERLY IN THIS HEATER.
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
5. OVERVIEW OF HEATERS DESIGN
7. OPERATION
Fuel System : This heater is equipped with an electric
air pump that forces air through the air
line connected to the fuel intake and then
through a nozzle in the burner head.
A.) VENTILATION
RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS.
Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr.
rating. Provide extra fresh air if more heaters are being used.
Example : A RMC-KFA170T-DLX heater requires one of the following:
• a two-car garage door raised six inches (15.24 cm)
When the air passes in front of the fuel
intake it causes fuel to rise from the tank
and into the burner nozzle. This fuel and
air mixture is then sprayed into the
• a single-car garage door raised nine inches (22.86 cm)
• two, thirty-inch (76.20 cm) windows raised fifteen inches (38.1 cm
combustion chamber in a fine mist.
B.) OPERATION
“Sure Fire Ignition” : The electronic ignitor sends voltage to a specially designed spark plug.
TO START HEATER
The spark plug ignites the fuel and air mixture described above.
1. Fill fuel tank with kerosene or No. 1 fuel oil.
2. Attach fuel cap.
The Air System : The heavy duty motor turns a fan that forces air into and around the combustion
3. Plug power cord of heater into three-prong, grounded extension cord. Extension cord must be at
least six feet long.
chamber. Here the air is heated and then forced out the front of the heater.
The Safety System :
Extension Cord Wire Size Requirements :
A. Temperature Limit Control : This heater is equipped with a Temperature Limit Control designed to turn
off the heater should the internal temperature rise to an unsafe level. If this
device activates and turns your heater off it may require service.
• 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.
• 11 to 100 feet (3.4 to 30.5 meters) long, use 16 AWG conductor.
• 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.
4. Turn “THERMOSTAT CONTROL KNOB” to desired setting (setting range : 40˚F ~ 110˚F) and
push power switch to ON” position, power indicator lamp will light and heater will start.
NOTE : Room Temp. display indicates as follows,
* When room temp. is less than 0℉ : "L "
* When room temp. is between 0℉ and 99℉ : Indicates room temperature.
* When room temp. is more than 99℉ : "Hi"
Internal Shut-Off Temp.
Plus/Minus 10 Degrees
230˚F/110˚C
Reset Temperature
Plus/Minus 10 Degrees
194˚F/90˚C
MODELS
RMC-KFA120TDLX/KFA170TDLX
RMC-KFA65TDLX
176˚F/80˚C
122˚F/50˚C
Once the temperature falls below the reset temperature you will be able to start your heater.
If heater does not start, the thermostat setting may be too low,turn "THERMOSTAT CONTROL KNOB" to
higher positon to start heater. If heater still does not start, turn power switch to "OFF" and then to "ON"
position.(See Figure9). If heater still does not start,see Troubleshooting Guide on page 16.
B. Electrical System Protection : The heaters electrical system is protected by a circuit breaker mounted to
the power switch that protects the PCB assembly and other electrical
components from damage. If your heater fails to operate check this fuse
first and replace as needed.
Figure 9.
Power ON/OFF & Temp. Setting.
FUSE TYPE:
All Models
125 volt / 8 amps
C. Flame-Out Sensor : Utilizes a photocell to monitor the flame in burn chamber during normal operation.
It will cause the heater to shut-off should the burner flame extinguish.
NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the
PCB board. If your heater fails to start, check this fuse first and replace as necessary. You
should also check your power source to insure that proper voltage and frequency are being
supplied to the heater.
6. FUELING YOUR HEATER
NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK
OUTDOORS.
DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED.
IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER :
The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in
manufacturing the heater to burn off outside.
WARNING!! : NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR
STILL HOT.
TO STOP HEATER
1. Turn switch to “OFF” and unplug power cord.
TO RESTART HEATER
1.Wait 10 seconds after stopping heater.
2. Repeat steps under to start heater.
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
8. LONG TERM STORAGE OF YOUR HEATER
9. MAINTENANCE
WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR
WHILE HOT!
FUEL TANK DRAIN
1. Remove Fuel Cap and Cap Fuel Filter(See Figure 10).
USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or
other alternate components will void warranty and may cause unsafe operating
conditions.
2. Drain Fuel Tank through Fuel Cap Opening and wash Fuel Cap Filter with clean fuel.
3.Using a small amount of kerosene,swirl and rinse the inside of the tank.
Never mix water with the kerosene as it will cause poor operation of the heater.
Pour the kerosene out making sure that you remove it all.
IMPORTANT : Do not store kerosene over summer months for use during next next heating season.
Using old fuel could damage heater.
A.) FUEL TANK
FLUSH EVERY 200 HOURS OF
OPERATION OR AS NEEDED (SEE
STORAGE, PAGE 9)
4. Reinstall Fuel Cap Filter and Fuel Cap(See Figure 11).
IMPORTANT : Reinstall Fuel Cap Filter fully into Fuel Cap Opening on tank,
Otherwise it will not install completely.
B.) UPPER SHELL REMOVAL
-Remove Screw that secure Side Cover.
-Push out for arrow direction and extract Side
Cover's Bracket from Rectancle Hole and
Separate Side Cover(R).
-Side Cover(L) in opposite of Side Cover(R)
Separates by same method.
(RMC-KFA120T/170TDLX Models Only.)
-Remove 4 Screws along each side of heater
using medium phillips screwdriver. These
Screws attach Upper Rear and Lower shells
together. (See Figure 12)
Figure 12. Upper Shell Removal.
(RMC-KFA65TDLX Model Only.)
-Remove Screws along each side of heater using
medium phillips screwdriver. These Screws
attach Upper and Lower shells together.
Figure 10. Remove Fuel Cap and Filter
Figure 11. Reinstall Fuel Cap Filter
5.Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.
C.) AIR OUTPUT,AIR INTAKE AND
LINT FILTERS WASH AND DRY
WITH SOAP AND WATER OR
REPLACE EVERY 500 HOURS OF
OPERATION OR ONCE A YEAR.
-Remove Upper Shell.(See Figure 12)
6.Store the heater in the original box with the original packing material and keep the USER'S MANUAL
with the heater.
-Remove Fan guard.(See Figure 13)
Figure 13. Air Output,Intake,and Lint Filters
-Remove End Filter Cover Screws using
medium phillips screwdriver.
-Remove End Filter Cover.
-Replace Air Output and Lint Filters.
-Wash or Replace Air Intake Filter.
-Reinstall Fan Guard and Upper Shell.
9
10
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
D.) FAN BLADES
F.) SPARK PLUG
CLEAN EVERY SEASON OR AS NEEDED.
-Remove upper shell(See 10 page.)
CLEAN AND REGAP EVERY 600 HOURS
OF OPERATION OR REPLACE AS
NEEDED.
-Use 1/8" allen wrench to loosen set screw
which holds Fan Blade to motor shaft.
-Remove upper shell(See 10 page).
-Remove Fan Blade(See 11 Page).
- Slip Fan Blade off motor shaft.
-Remove Ignitor Wire from Spark Plug.
-Clean Fan Blade using a soft colth moistened
with kerosene or solvent.
-Remove Spark Plug from Burner Head using
medium phillips screwdriver.
-Dry Fan Blade throughly.
-Clean and regap Spark plug electrodes to
0.140″(3.5mm) gap.
-Reinstall Fan Blade on motor shaft. Place Fan
Blade hub flush with end of motor shaft.
-Reinstall Spark Plug in Burner Head.
-Attach Ignitor wire to Spark Plug.
-Reinstall Fan and Upper Shell.
-Place Set Screw on flat of shaft. Tighten Set Screw
firmly(40~50 inch-pounds/4.5~5.6 N-m).
Figure 14. Fan and Setscrew Location.
Figure 16. Removing Spark Plug
E.) NOZZLE
REMOVE DIRT IN NOZZLE AS
NEEDED(See Page 14)
G.) PHOTOCELL
CLEAN PHOTOCELL ANNUALLY OR AS
-Remove Upper Shell(See page 10).
NEEDED.
-Remove upper shell(See page 10).
-Remove Fan Blade(See Fan Blades).
-Remove Fuel and Air Line from Burner Head.
-Remove Ignitor Wire from Spark Plug.
-Remove fan (See page 11).
-Remove photocell from photocell bracket.
-Clean photocell lens with cotton swab.
-Remove three Screws using medium phillips
screwdriver and remove Burner Head from
combustion chamber.
TO REPLACE:
-Remove Spark Plug from Burner Head using
medium phillips screwdriver.
-Disconnect switch wires from power switch.
-Carefully remove Nozzle from Burner Head
using 5/8" socket wrench.
-Remove two Screws using medium phillips
screwdriver.
-Blow compressed air through face of
Nozzle.(this will remove any dirt in Nozzle)
These Screws attach Main PCB to Side
Cover.(See Figure 17)
-Reinstall Nozzle into Burner Head and tighten
firmly. (80~110 inch-pounds)
-Remove Side cover(R).
-Disconnect Photocell Connector from Circuit
Board and remove photocell.
-Reinstall Spark Plug in Burner Head.
-Attach Ignitor wire to Spark Plug.
-Install new Photocell and connect photocell
connector to Circuit Board.
-Attach Fuel and Air Line to Burner Head.
-Reinstall Fan Blade and Upper Shell.
-Replace Circuit Board to Side Cover(R) and
Switch wires to Power Switch.
-Replace Fan and Upper Shell.
Figure 15. Removing Nozzle
Figure 17. Replace & Cleaning Photocell
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
H.) FUEL FILTER
10. TROUBLE SHOOTING GUIDE
CLEAN OR REPLACE TWICE A HEATING
SEASON OR AS NEED.
-Remove upper shell(See 10 page).
-Remove Fan Blade(See 11 Page).
-Pull Fuel Line off from Fuel Filter Neck.
-Remove Fuel Filter.
-Wash Fuel Filter with clean kerosene and replace
in tank.
-Attach Fuel Line to Fuel Filter Neck.
-Replace Fan Blade and Upper Shell.
Figure 18. Removing Fuel Filter
I.) PUMP PRESSURE ADJUSTMENT
-Start Heater(See Operation, Page 8) and allow
motor to reach full speed.
-Adjust Pump Pressure.(Using a Flat blade
screwdriver)
Turn Relief Valve clockwise to increase pressure.
Turn Relief Valve counter-clockwise to decrease
pressure.
Set Pump pressure according to the chart below.
-Stop Heater(See Operation, Page 8).
MODEL
PUMP PRESSURE
3.5 psi
RMC-KFA65TDLX
RMC-KFA120TDLX
RMC-KFA170TDLX
4.5 psi
6.5 psi
Figure 19. Adjusting Pump Pressure
NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.
USE OF ALTERNATE OR THIRD PARTY COMPONENTS WILL VOID ANY WARRANTY
AND MAY CAUSE UNSAFE OPERATING CONDITION.
13
14
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
11. WIRING DIAGRAM
12. SPECIFICATIONS
A) WIRING DIAGRAM(RMC-KFA65TDLX)
RMC-KFA65TDLX
KFA120T-DLX
KFA170T-DLX
H
D
25"
25"
32.1"
18.5"
36.9"
18.5"
B) WIRING DIAGRAM(RMC-KFA120TDLX/RMC-KFA170TDLX)
W
RMC-KFA120TDLX / RMC-KFA170TDLX
MODEL
RMC-KFA65TDLX RMC-KFA120TDLX RMC-KFA170TDLX
BTU/Hr.
65,000
120,000
170,000
Fuel Consumption - Gal./Hr.
FuelTank Capacity - Gal.
Pump Pressure PSI
Volt/Hz
0.5
0.9
1.3
5.0
10.0
12.0
3.5
4.5
6.5
120Vac/60Hz
120Vac/60Hz
120Vac/60Hz
Amps.
1.6
2.5
3.2
Phase
1
14.5"× 25.8" ×16.8"
26.5
1
1
18.5"× 36.9"×25"
52
Size (W×D×H)
Weight (Lbs.)
18.5"× 32.1"×25"
48.5
15
16
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
13. EXPLODED PARTS DRAWING
14. PARTS LIST(RMC-KFA65TDLX Model Only)
KEY NO.
DESCRIPTION
PARTNO.
KEY NO.
DESCRIPTION
Capacitor
Motor Supportor
Lock Nut.
Pump Body
Bolt-PH
Insert
Rotor Kit
Blade
End Pump Cover
Nipple(Air)
Flange Bolt
Lint Filter
Output Filter
Filter Kit
End Filter Cover
Ball
PARTNO.
3211-0018-00
2156-0023-00
3231-0123-00
3221-0063-00
3231-0122-00
2155-0009-00
2151-0015-00
3231-0120-00
3231-0121-00
3713-0022-00
3131-0182-00
3712-0013-00
3980-0102-00
3341-0007-00
2153-0003-00
4319-0015-00
2152-0072-00
3131-0159-00
4311-0068-00
SP-KFA1007
See below
3531-0015-00
3541-0020-00
3541-0039-00
SP-KFA1027
4343-0016-00
3431-0010-00
3311-0002-00
SP-KFA1008
4349-0017-00
4342-0009-00
4329-0013-00
3341-0016-00
See below
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Fuel Tank Assembly
Fuel Gauge
Fuel Gauge Cap
Fuel Cap Filter
Fuel Cap
Fuel Filter Assembly
Shell Lower Assembly
Bushing Grommet(S)
Bushing Grommet(L)
Twist Lock Stand Off
Nut Clip
Cord Bushing
Power Cord
Air Line
Temperature Limit Control
Flange Screw
Combustion Chamber
Photocell Bracket
Screw-BH
Photocell Assembly
Burner Head Assembly
Burner Head
Nipple(Air)
Nipple(Fuel)
Nozzle
23-2
23-3
23-4
23-5
23-6
23-7
23-8
23-9
23-10
23-11
23-12
23-13
23-14
23-15
23-16
23-17
23-18
23-19
23-20
24
25
26
27
28
29
30
31
32
32-1
32-2
33
34
35
3820-0142-00
3121-0358-00
4331-0022-00
3541-0022-00
4321-0038-00
See SP-KFA1000
SP-KFA1000
See SP-KFA1000
3531-0008-00
3541-0020-00
4329-0014-00
See SP-KFA1005
See SP-KFA1005
SP-KFA1005
3221-0029-00
See SP-KFA1006
See SP-KFA1006
SP-KFA1006
4319-0015-00
2154-0009-00
4323-0004-00
3740-0049-01
3221-0050-00
39E0-0025-00
4311-0024-00
2151-0018-00
3211-0019-00
215A-0026-00
SP-KFA1018
3231-0111-01
3211-0021-00
3131-0348-00
3221-0058-00
39A0-0044-00
3211-0023-00
Spring
17
18
19
20
Plug/Pump Adj.Kit
Flange Screw
Fan Assembly
Set Screw
Pressure Gauge
Fan Guard
Ignitor
Screw-PH2
Shell Upper Assembly
Shell Cover
Main P.C.B Assembly
Fuse
Thermostat Control Knob
Side Cover(R)
BRACKET SIDE COVER
RATING PLATE
Power Switch
Side Cover(L)
21
21-1
21-2
21-3
21-4
21-5
21-6
21-7
21-8
21-9
21-10
21-11
22
Nozzle Seal Washer
Nozzle Seal Spring
Nozzle Sleeve
Spark Plug
Fiber Washer
Spring Washer
Flange Bolt
Fuel Line
Motor and Pump Assembly
Motor
23
23-1
36
37
3970-0034-00
ACCESSORIES
Air Pressure Gauge
Thermostat
SP-KFA1011 (all models)
SP-KFA1010 (all models)
FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR
CONTACT US AT:
Phone : 1-800-668-5323
17
18
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
15. EXPLODED PARTS DRAWING(RMC-KFA120T/170TDLX Models Only)
16. PARTS LIST(RMC-KFA120T/170TDLX Models Only)
PART NO.
KEY NO.
DESCRIPTION
Fuel Tank Assembly
RMC-KFA120TDLX
2151-0012-00
2156-0022-00
3231-0123-00
3221-0063-00
3231-0122-00
2155-0010-00
2151-0014-00
3231-0120-00
3231-0121-00
3713-0022-00
3131-0182-00
3712-0013-00
3980-0031-00
3341-0002-00
2153-0001-00
4319-0015-00
2152-0073-00
3131-0159-00
4311-0068-00
SP-KFA1007
See below
3531-0007-00
3541-0020-00
3541-0020-00
SP-KFA1003
4343-0016-00
3431-0010-00
3311-0002-00
SP-KFA1009
4349-0017-00
4342-0009-00
4329-0013-00
3341-0017-00
See below
3970-0029-00
3820-0143-00
3121-0357-00
4331-0022-00
3541-0022-00
4321-0038-00
See SP-KFA1000
RMC-KFA170TDLX
2151-0011-00
2156-0022-00
3231-0123-00
3221-0063-00
3231-0122-00
2155-0010-00
2151-0014-00
3231-0120-00
3231-0121-00
3713-0022-00
3131-0182-00
3712-0013-00
3980-0031-00
3341-0004-00
2153-0001-00
4319-0015-00
2152-0074-00
3131-0159-00
4311-0068-00
SP-KFA1007
See below
3531-0007-00
3541-0020-00
3541-0020-00
SP-KFA1004
4343-0016-00
3431-0010-00
3311-0002-00
SP-KFA1009
4349-0017-00
4342-0009-00
4329-0013-00
3341-0017-00
See below
3970-0033-00
3820-0143-00
3121-0357-00
4331-0022-00
3541-0022-00
4321-0038-00
See SP-KFA1000
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Fuel Gauge
Fuel Gauge Cap
Fuel Cap Filter
Fuel Cap
Fuel Filter Assembly
Shell Lower Assembly
Bushing Grommet(S)
Bushing Grommet(L)
Twist Lock Stand Off
Nut Clip
Cord Bushing
Power Cord
Air Line
Temperature Limit Control
Flange Screw
Combustion Chamber
Photocell Bracket
Screw-BH
Photocell Assembly
Burner Head Assembly
Burner Head
17
18
19
20
21
21-1
21-2
21-3
21-4
21-5
21-6
21-7
21-8
21-9
21-10
21-11
22
Nipple(Air)
Nipple(Fuel)
Nozzle
Nozzle Seal Washer
Nozzle Seal Spring
Nozzle Sleeve
Spark Plug
Fiber Washer
Spring Washer
Flange Bolt
Fuel Line
Motor and Pump Assembly
Motor
Capacitor
Motor Supportor
Lock Nut.
Pump Body
Bolt-PH
23
23-1
23-2
23-3
23-4
23-5
23-6
23-7
Insert
19
20
Download from Www.Somanuals.com. All Manuals Search And Download.
NEVER LEAVE THE HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
UNATTENDED WHILE BURNING!
17. PARTS LIST (WHEELS AND HANDLE)
1) RMC-KFA65TDLX MODEL
PART NO.
KEY NO.
DESCRIPTION
RMC-KFA120TDLX
SP-KFA1000
RMC-KFA170TDLX
SP-KFA1000
Rotor Kit
Blade
23-8
23-9
23-10
23-11
23-12
23-13
23-14
23-15
23-16
23-17
23-18
23-19
23-20
24
25
26
27
28
29
30
31
32
See SP-KFA1000
3531-0008-00
3541-0020-00
4329-0014-00
See SP-KFA1005
See SP-KFA1005
SP-KFA1005
3221-0029-00
See SP-KFA1006
See SP-KFA1006
SP-KFA1006
4319-0015-00
2154-0004-00
4323-0004-00
3740-0049-01
3221-0051-00
39E0-0025-00
4311-0024-00
3111-0220-00
3111-0223-00
3211-0020-00
215A-0023-00
SP-KFA1018
3231-0111-01
3211-0022-00
3131-0348-00
3221-0059-01
39A0-0044-00
3211-0024-00
See SP-KFA1000
3531-0008-00
3541-0020-00
4329-0014-00
See SP-KFA1005
See SP-KFA1005
SP-KFA1005
3221-0029-00
See SP-KFA1006
See SP-KFA1006
SP-KFA1006
4319-0015-00
2154-0007-00
4323-0004-00
3740-0049-01
3221-0051-00
39E0-0025-00
4311-0024-00
3111-0221-00
3111-0224-00
3211-0020-00
215A-0023-00
SP-KFA1018
3231-0111-01
3211-0022-00
3131-0348-00
3221-0059-00
39A0-0044-00
3211-0024-00
PART NO.
KEY
DESCRIPTION
QTY
End Pump Cover
Nipple(Air)
Flange Bolt
NO.
1
RMC-KFA65TDLX
3231-0125-00
Handle
1
1
1
2
Cord Wrap
Hardware Kit
3231-0056-00
Lint Filter
3
HW-KFA1001
Output Filter
Filter Kit
End Filter Cover
Ball
2) RMC-KFA120T/170TDLX MODELS
PART NO.
Spring
KEY NO.
DESCRIPTION
QTY
RMC-KFA120TDLX
RMC-KFA170TDLX
Plug/Pump Adj.Kit
Flange Screw
Fan Assembly
Set Screw
Pressure Gauge
Fan Guard
1
2
Handle Front
Handle
3551-0039-00
3551-0040-00
1
1
1
1
2
2
1
4
4
2
2
2
3231-0126-00
3231-0126-00
3
Cord Wrap
Wheel Axle
Wheel
3221-0057-00
3221-0057-00
4
3541-0064-00
3541-0064-00
5
2156-0026-00
2156-0026-00
Ignitor
Screw-PH2
6
Wheel Cap
Hardware Kit
Screw(A)
Screw(B)
Flat Washer
Cotter Pin
Bushing
3231-0100-00
3231-0100-00
7
HW-KFA1008
HW-KFA1008
Shell Upper Front
Shell Upper Rear
Shell Cover
Main P.C.B Assembly
Fuse
Thermostat Control Knob
Side Cover(R)
BRACKET SIDE COVER
RATING PLATE
Power Switch
Side Cover(L)
7-1
7-2
7-3
7-4
7-5
-
-
-
-
-
-
-
-
-
-
33
33-1
33-2
34
35
36
37
38
ACCESSORIES
Air Pressure Gauge
Thermostat
SP-KFA1011 (all models)
SP-KFA1010 (all models)
FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR