Dyna Glo Electric Heater RMC KFA65TDLX RMC KFA120TDLX RMC KFA170TDLX User Manual

PORTABLE  
FORCED AIR HEATERS  
“USER’S MANUAL”  
LISTED  
MODEL : RMC-KFA65TDLX, RMC-KFA120TDLX  
RMC-KFA170TDLX  
Before the first use of this heater, please read this USER’S MANUAL very  
carefully. This USER’S MANUAL has been designed to instruct you as to  
the proper manner in which to assemble, maintain, store, and most  
importantly, how to operate the heater in a safe and efficient manner.  
Please keep this manual for future reference.  
CFM HOME PRODUCTS  
2695 MEADOWVALE BOULEVARD  
MISSISSAUGA, ONTARIO L5N 8A3  
1-800-668-5323  
4221- 0059-00  
06/04 Rev. 00  
EDITION 2004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
3. UNPACKING AND ASSEMBLY  
1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX.  
NOTE : Save the shipping carton and packing materials for future storage.  
RMC-KFA/65TDLX RMC-KFA120TDLX RMC-KFA170TDLX  
Wheel  
Wheel Bar  
No  
No  
No  
No  
Yes  
Yes  
Yes  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Wheel Cap  
Front Handle  
Handle  
Cord Wrap  
Screws  
Screws(A) and Screws(B)  
Bushing  
Cotter Pin and Washer  
Screws  
Hardware Kit Part No :  
HW-KFA1001  
Figure 2. RMC-KFA120TDLX  
Handle  
Cord Wrap  
Figure 4. RMC-KFA65TDLX MODEL  
Screws(A) Screws(B)  
Washers  
Bushing  
Cotter Pins  
Wheels  
Cord Wrap  
Hardware Kit Part No : HW-KFA1008  
Wheels Caps  
Front Handle  
Wheel Axle  
Figure 3. RMC-KFA170TDLX  
Figure 5. RMC-KFA120TDLX / RMC-KFA170TDLX MODELS  
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
2. ASSEMBLY  
A. For RMC-KFA65TDLX Model only (See Figure 6,7)  
Tools Required  
• Medium Phillips Screwdriver  
1. Assembling Handle.  
1) Align boss on bottom of handle with the 2 holes on  
the shell cover as shown in Figure 6  
NOTE : Be sure to match the tab in the bottom of the  
handle with the slot in housing cover.  
2) Insert screws into the holes in the handle and tighten  
each screw.  
Figure 6. Handle Assembly  
2. Assembling Cord Wrap  
1) Align 2 boss on the cordwrap with the 2 holes on the  
side cover as shown in Figure 7  
2) Insert screws into the holes in the cord wrap and  
tighten each screw.  
B. For RMC-KFA120TDLX/RMC-KFA170TDLX  
Models Only.  
These models are furnished with wheels, front handle,  
handle and cordwrap, Wheels, Handles, Cordwraps and  
the mounting hardware are found in the shipping carton.  
Figure 7. Cord Wrap Assembly  
Figure 8. Wheel and Handle Assembly, RMC-KFA120TDLX/RMC-KFA170TDLX Models Only.  
NOTE : Heater should be inspected before each use, and at least annually by a qualitied service person.  
Tools Required  
• Medium Phillips Screwdriver  
• 38" Open or Adjustable Wrench, Use US(Inch) Screws Nuts.  
• Long Nose Pliers  
4. KEROSENE (1-K)  
For optimal performance of this heater, it is strongly suggested that 1-K kerosene be used. 1-K kerosene has  
been refined to virtually eliminate contaminants, such as sulpher. Which can cause a rotten egg odor during  
the operation of the heater. However, #1 or #2 fuel oil (diesel fuel) may also be used if 1-K kerosene is not  
available. Be advised that these fuels do not burn as clean as 1-K kerosene, and care should be taken to  
provide more fresh air ventilation to accomodate any added contaminants that may be added to the heated  
space.  
1. Assembling Wheel & Front Handle  
1) Slide one Wheel & Bushing over the Wheel Axle,making sure that the extended hub of the wheel points  
towards the wheel points towards the Wheel Support(See Figure 8,Page 6).  
2) Slide Flat Washer over Wheel Axle end,past the hole in the axle.  
Slide Cotter Pin into the hole in the Wheel axle, and using your pliers bend the legs of the Cotter Pin  
until it can not be removed.  
3) Slide Wheel Axle through Wheel Support and assemble the Bushing Wheel, Flat Washer and Cotter Pin  
as in Steps 1 and 2.  
4) Place Wheel Caps on Flat Washers until they snap in place securely.  
5) Place Front Handle on shell flange and insert screws through front handle, shell flange and tighten each  
screw after each screw is inserted.  
KEROSENE SHOULD ONLY BE STORED IN A BLUE CONTAINER THAT IS CLEARLY  
MARKED “KEROSENE”. NEVER STORE KEROSENE IN A RED CONTAINER.  
Red containers are associated with gasoline.  
NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated place outside the  
living area.  
NEVER use any fuel other than 1-K kerosene (#1 fuel oil is an acceptable substitute.)  
NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other oil  
compounds in this heater. These are volatile fuels that can cause an explosion or uncontrolled flames.  
NEVER store kerosene in direct sunlight or near a source of heat.  
2. Assembling Handle & Cord Wrap.  
1) Assembling Handle : Assemble by method described above for model RMC-KFA65TDLX.  
2) Assembling Cord Wrap : Assemble by method described above for model RMC-KFA65TDLX.  
NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time.  
“OLD KEROSENE” WILL NOT BURN PROPERLY IN THIS HEATER.  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
5. OVERVIEW OF HEATERS DESIGN  
7. OPERATION  
Fuel System : This heater is equipped with an electric  
air pump that forces air through the air  
line connected to the fuel intake and then  
through a nozzle in the burner head.  
A.) VENTILATION  
RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS.  
Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr.  
rating. Provide extra fresh air if more heaters are being used.  
Example : A RMC-KFA170T-DLX heater requires one of the following:  
• a two-car garage door raised six inches (15.24 cm)  
When the air passes in front of the fuel  
intake it causes fuel to rise from the tank  
and into the burner nozzle. This fuel and  
air mixture is then sprayed into the  
• a single-car garage door raised nine inches (22.86 cm)  
• two, thirty-inch (76.20 cm) windows raised fifteen inches (38.1 cm  
combustion chamber in a fine mist.  
B.) OPERATION  
“Sure Fire Ignition” : The electronic ignitor sends voltage to a specially designed spark plug.  
TO START HEATER  
The spark plug ignites the fuel and air mixture described above.  
1. Fill fuel tank with kerosene or No. 1 fuel oil.  
2. Attach fuel cap.  
The Air System : The heavy duty motor turns a fan that forces air into and around the combustion  
3. Plug power cord of heater into three-prong, grounded extension cord. Extension cord must be at  
least six feet long.  
chamber. Here the air is heated and then forced out the front of the heater.  
The Safety System :  
Extension Cord Wire Size Requirements :  
A. Temperature Limit Control : This heater is equipped with a Temperature Limit Control designed to turn  
off the heater should the internal temperature rise to an unsafe level. If this  
device activates and turns your heater off it may require service.  
• 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.  
• 11 to 100 feet (3.4 to 30.5 meters) long, use 16 AWG conductor.  
• 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.  
4. Turn “THERMOSTAT CONTROL KNOB” to desired setting (setting range : 40˚F ~ 110˚F) and  
push power switch to ON” position, power indicator lamp will light and heater will start.  
NOTE : Room Temp. display indicates as follows,  
* When room temp. is less than 0: "L "  
* When room temp. is between 0and 99: Indicates room temperature.  
* When room temp. is more than 99: "Hi"  
Internal Shut-Off Temp.  
Plus/Minus 10 Degrees  
230˚F/110˚C  
Reset Temperature  
Plus/Minus 10 Degrees  
194˚F/90˚C  
MODELS  
RMC-KFA120TDLX/KFA170TDLX  
RMC-KFA65TDLX  
176˚F/80˚C  
122˚F/50˚C  
Once the temperature falls below the reset temperature you will be able to start your heater.  
If heater does not start, the thermostat setting may be too low,turn "THERMOSTAT CONTROL KNOB" to  
higher positon to start heater. If heater still does not start, turn power switch to "OFF" and then to "ON"  
position.(See Figure9). If heater still does not start,see Troubleshooting Guide on page 16.  
B. Electrical System Protection : The heaters electrical system is protected by a circuit breaker mounted to  
the power switch that protects the PCB assembly and other electrical  
components from damage. If your heater fails to operate check this fuse  
first and replace as needed.  
Figure 9.  
Power ON/OFF & Temp. Setting.  
FUSE TYPE:  
All Models  
125 volt / 8 amps  
C. Flame-Out Sensor : Utilizes a photocell to monitor the flame in burn chamber during normal operation.  
It will cause the heater to shut-off should the burner flame extinguish.  
NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the  
PCB board. If your heater fails to start, check this fuse first and replace as necessary. You  
should also check your power source to insure that proper voltage and frequency are being  
supplied to the heater.  
6. FUELING YOUR HEATER  
NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK  
OUTDOORS.  
DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED.  
IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER :  
The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in  
manufacturing the heater to burn off outside.  
WARNING!! : NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR  
STILL HOT.  
TO STOP HEATER  
1. Turn switch to “OFF” and unplug power cord.  
TO RESTART HEATER  
1.Wait 10 seconds after stopping heater.  
2. Repeat steps under to start heater.  
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
8. LONG TERM STORAGE OF YOUR HEATER  
9. MAINTENANCE  
WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR  
WHILE HOT!  
FUEL TANK DRAIN  
1. Remove Fuel Cap and Cap Fuel Filter(See Figure 10).  
USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or  
other alternate components will void warranty and may cause unsafe operating  
conditions.  
2. Drain Fuel Tank through Fuel Cap Opening and wash Fuel Cap Filter with clean fuel.  
3.Using a small amount of kerosene,swirl and rinse the inside of the tank.  
Never mix water with the kerosene as it will cause poor operation of the heater.  
Pour the kerosene out making sure that you remove it all.  
IMPORTANT : Do not store kerosene over summer months for use during next next heating season.  
Using old fuel could damage heater.  
A.) FUEL TANK  
FLUSH EVERY 200 HOURS OF  
OPERATION OR AS NEEDED (SEE  
STORAGE, PAGE 9)  
4. Reinstall Fuel Cap Filter and Fuel Cap(See Figure 11).  
IMPORTANT : Reinstall Fuel Cap Filter fully into Fuel Cap Opening on tank,  
Otherwise it will not install completely.  
B.) UPPER SHELL REMOVAL  
-Remove Screw that secure Side Cover.  
-Push out for arrow direction and extract Side  
Cover's Bracket from Rectancle Hole and  
Separate Side Cover(R).  
-Side Cover(L) in opposite of Side Cover(R)  
Separates by same method.  
(RMC-KFA120T/170TDLX Models Only.)  
-Remove 4 Screws along each side of heater  
using medium phillips screwdriver. These  
Screws attach Upper Rear and Lower shells  
together. (See Figure 12)  
Figure 12. Upper Shell Removal.  
(RMC-KFA65TDLX Model Only.)  
-Remove Screws along each side of heater using  
medium phillips screwdriver. These Screws  
attach Upper and Lower shells together.  
Figure 10. Remove Fuel Cap and Filter  
Figure 11. Reinstall Fuel Cap Filter  
5.Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.  
C.) AIR OUTPUT,AIR INTAKE AND  
LINT FILTERS WASH AND DRY  
WITH SOAP AND WATER OR  
REPLACE EVERY 500 HOURS OF  
OPERATION OR ONCE A YEAR.  
-Remove Upper Shell.(See Figure 12)  
6.Store the heater in the original box with the original packing material and keep the USER'S MANUAL  
with the heater.  
-Remove Fan guard.(See Figure 13)  
Figure 13. Air Output,Intake,and Lint Filters  
-Remove End Filter Cover Screws using  
medium phillips screwdriver.  
-Remove End Filter Cover.  
-Replace Air Output and Lint Filters.  
-Wash or Replace Air Intake Filter.  
-Reinstall Fan Guard and Upper Shell.  
9
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
D.) FAN BLADES  
F.) SPARK PLUG  
CLEAN EVERY SEASON OR AS NEEDED.  
-Remove upper shell(See 10 page.)  
CLEAN AND REGAP EVERY 600 HOURS  
OF OPERATION OR REPLACE AS  
NEEDED.  
-Use 1/8" allen wrench to loosen set screw  
which holds Fan Blade to motor shaft.  
-Remove upper shell(See 10 page).  
-Remove Fan Blade(See 11 Page).  
- Slip Fan Blade off motor shaft.  
-Remove Ignitor Wire from Spark Plug.  
-Clean Fan Blade using a soft colth moistened  
with kerosene or solvent.  
-Remove Spark Plug from Burner Head using  
medium phillips screwdriver.  
-Dry Fan Blade throughly.  
-Clean and regap Spark plug electrodes to  
0.140(3.5mm) gap.  
-Reinstall Fan Blade on motor shaft. Place Fan  
Blade hub flush with end of motor shaft.  
-Reinstall Spark Plug in Burner Head.  
-Attach Ignitor wire to Spark Plug.  
-Reinstall Fan and Upper Shell.  
-Place Set Screw on flat of shaft. Tighten Set Screw  
firmly(40~50 inch-pounds/4.5~5.6 N-m).  
Figure 14. Fan and Setscrew Location.  
Figure 16. Removing Spark Plug  
E.) NOZZLE  
REMOVE DIRT IN NOZZLE AS  
NEEDED(See Page 14)  
G.) PHOTOCELL  
CLEAN PHOTOCELL ANNUALLY OR AS  
-Remove Upper Shell(See page 10).  
NEEDED.  
-Remove upper shell(See page 10).  
-Remove Fan Blade(See Fan Blades).  
-Remove Fuel and Air Line from Burner Head.  
-Remove Ignitor Wire from Spark Plug.  
-Remove fan (See page 11).  
-Remove photocell from photocell bracket.  
-Clean photocell lens with cotton swab.  
-Remove three Screws using medium phillips  
screwdriver and remove Burner Head from  
combustion chamber.  
TO REPLACE:  
-Remove Spark Plug from Burner Head using  
medium phillips screwdriver.  
-Disconnect switch wires from power switch.  
-Carefully remove Nozzle from Burner Head  
using 5/8" socket wrench.  
-Remove two Screws using medium phillips  
screwdriver.  
-Blow compressed air through face of  
Nozzle.(this will remove any dirt in Nozzle)  
These Screws attach Main PCB to Side  
Cover.(See Figure 17)  
-Reinstall Nozzle into Burner Head and tighten  
firmly. (80~110 inch-pounds)  
-Remove Side cover(R).  
-Disconnect Photocell Connector from Circuit  
Board and remove photocell.  
-Reinstall Spark Plug in Burner Head.  
-Attach Ignitor wire to Spark Plug.  
-Install new Photocell and connect photocell  
connector to Circuit Board.  
-Attach Fuel and Air Line to Burner Head.  
-Reinstall Fan Blade and Upper Shell.  
-Replace Circuit Board to Side Cover(R) and  
Switch wires to Power Switch.  
-Replace Fan and Upper Shell.  
Figure 15. Removing Nozzle  
Figure 17. Replace & Cleaning Photocell  
11  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
H.) FUEL FILTER  
10. TROUBLE SHOOTING GUIDE  
CLEAN OR REPLACE TWICE A HEATING  
SEASON OR AS NEED.  
-Remove upper shell(See 10 page).  
-Remove Fan Blade(See 11 Page).  
-Pull Fuel Line off from Fuel Filter Neck.  
-Remove Fuel Filter.  
-Wash Fuel Filter with clean kerosene and replace  
in tank.  
-Attach Fuel Line to Fuel Filter Neck.  
-Replace Fan Blade and Upper Shell.  
Figure 18. Removing Fuel Filter  
I.) PUMP PRESSURE ADJUSTMENT  
-Start Heater(See Operation, Page 8) and allow  
motor to reach full speed.  
-Adjust Pump Pressure.(Using a Flat blade  
screwdriver)  
Turn Relief Valve clockwise to increase pressure.  
Turn Relief Valve counter-clockwise to decrease  
pressure.  
Set Pump pressure according to the chart below.  
-Stop Heater(See Operation, Page 8).  
MODEL  
PUMP PRESSURE  
3.5 psi  
RMC-KFA65TDLX  
RMC-KFA120TDLX  
RMC-KFA170TDLX  
4.5 psi  
6.5 psi  
Figure 19. Adjusting Pump Pressure  
NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.  
USE OF ALTERNATE OR THIRD PARTY COMPONENTS WILL VOID ANY WARRANTY  
AND MAY CAUSE UNSAFE OPERATING CONDITION.  
13  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
11. WIRING DIAGRAM  
12. SPECIFICATIONS  
A) WIRING DIAGRAM(RMC-KFA65TDLX)  
RMC-KFA65TDLX  
KFA120T-DLX  
KFA170T-DLX  
H
D
25"  
25"  
32.1"  
18.5"  
36.9"  
18.5"  
B) WIRING DIAGRAM(RMC-KFA120TDLX/RMC-KFA170TDLX)  
W
RMC-KFA120TDLX / RMC-KFA170TDLX  
MODEL  
RMC-KFA65TDLX RMC-KFA120TDLX RMC-KFA170TDLX  
BTU/Hr.  
65,000  
120,000  
170,000  
Fuel Consumption - Gal./Hr.  
FuelTank Capacity - Gal.  
Pump Pressure PSI  
Volt/Hz  
0.5  
0.9  
1.3  
5.0  
10.0  
12.0  
3.5  
4.5  
6.5  
120Vac/60Hz  
120Vac/60Hz  
120Vac/60Hz  
Amps.  
1.6  
2.5  
3.2  
Phase  
1
14.5"× 25.8" ×16.8"  
26.5  
1
1
18.5"× 36.9"×25"  
52  
Size (W×D×H)  
Weight (Lbs.)  
18.5"× 32.1"×25"  
48.5  
15  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
13. EXPLODED PARTS DRAWING  
14. PARTS LIST(RMC-KFA65TDLX Model Only)  
KEY NO.  
DESCRIPTION  
PARTNO.  
KEY NO.  
DESCRIPTION  
Capacitor  
Motor Supportor  
Lock Nut.  
Pump Body  
Bolt-PH  
Insert  
Rotor Kit  
Blade  
End Pump Cover  
Nipple(Air)  
Flange Bolt  
Lint Filter  
Output Filter  
Filter Kit  
End Filter Cover  
Ball  
PARTNO.  
3211-0018-00  
2156-0023-00  
3231-0123-00  
3221-0063-00  
3231-0122-00  
2155-0009-00  
2151-0015-00  
3231-0120-00  
3231-0121-00  
3713-0022-00  
3131-0182-00  
3712-0013-00  
3980-0102-00  
3341-0007-00  
2153-0003-00  
4319-0015-00  
2152-0072-00  
3131-0159-00  
4311-0068-00  
SP-KFA1007  
See below  
3531-0015-00  
3541-0020-00  
3541-0039-00  
SP-KFA1027  
4343-0016-00  
3431-0010-00  
3311-0002-00  
SP-KFA1008  
4349-0017-00  
4342-0009-00  
4329-0013-00  
3341-0016-00  
See below  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
Fuel Tank Assembly  
Fuel Gauge  
Fuel Gauge Cap  
Fuel Cap Filter  
Fuel Cap  
Fuel Filter Assembly  
Shell Lower Assembly  
Bushing Grommet(S)  
Bushing Grommet(L)  
Twist Lock Stand Off  
Nut Clip  
Cord Bushing  
Power Cord  
Air Line  
Temperature Limit Control  
Flange Screw  
Combustion Chamber  
Photocell Bracket  
Screw-BH  
Photocell Assembly  
Burner Head Assembly  
Burner Head  
Nipple(Air)  
Nipple(Fuel)  
Nozzle  
23-2  
23-3  
23-4  
23-5  
23-6  
23-7  
23-8  
23-9  
23-10  
23-11  
23-12  
23-13  
23-14  
23-15  
23-16  
23-17  
23-18  
23-19  
23-20  
24  
25  
26  
27  
28  
29  
30  
31  
32  
32-1  
32-2  
33  
34  
35  
3820-0142-00  
3121-0358-00  
4331-0022-00  
3541-0022-00  
4321-0038-00  
See SP-KFA1000  
SP-KFA1000  
See SP-KFA1000  
3531-0008-00  
3541-0020-00  
4329-0014-00  
See SP-KFA1005  
See SP-KFA1005  
SP-KFA1005  
3221-0029-00  
See SP-KFA1006  
See SP-KFA1006  
SP-KFA1006  
4319-0015-00  
2154-0009-00  
4323-0004-00  
3740-0049-01  
3221-0050-00  
39E0-0025-00  
4311-0024-00  
2151-0018-00  
3211-0019-00  
215A-0026-00  
SP-KFA1018  
3231-0111-01  
3211-0021-00  
3131-0348-00  
3221-0058-00  
39A0-0044-00  
3211-0023-00  
Spring  
17  
18  
19  
20  
Plug/Pump Adj.Kit  
Flange Screw  
Fan Assembly  
Set Screw  
Pressure Gauge  
Fan Guard  
Ignitor  
Screw-PH2  
Shell Upper Assembly  
Shell Cover  
Main P.C.B Assembly  
Fuse  
Thermostat Control Knob  
Side Cover(R)  
BRACKET SIDE COVER  
RATING PLATE  
Power Switch  
Side Cover(L)  
21  
21-1  
21-2  
21-3  
21-4  
21-5  
21-6  
21-7  
21-8  
21-9  
21-10  
21-11  
22  
Nozzle Seal Washer  
Nozzle Seal Spring  
Nozzle Sleeve  
Spark Plug  
Fiber Washer  
Spring Washer  
Flange Bolt  
Fuel Line  
Motor and Pump Assembly  
Motor  
23  
23-1  
36  
37  
3970-0034-00  
ACCESSORIES  
Air Pressure Gauge  
Thermostat  
SP-KFA1011 (all models)  
SP-KFA1010 (all models)  
FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR  
CONTACT US AT:  
Phone : 1-800-668-5323  
17  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
15. EXPLODED PARTS DRAWING(RMC-KFA120T/170TDLX Models Only)  
16. PARTS LIST(RMC-KFA120T/170TDLX Models Only)  
PART NO.  
KEY NO.  
DESCRIPTION  
Fuel Tank Assembly  
RMC-KFA120TDLX  
2151-0012-00  
2156-0022-00  
3231-0123-00  
3221-0063-00  
3231-0122-00  
2155-0010-00  
2151-0014-00  
3231-0120-00  
3231-0121-00  
3713-0022-00  
3131-0182-00  
3712-0013-00  
3980-0031-00  
3341-0002-00  
2153-0001-00  
4319-0015-00  
2152-0073-00  
3131-0159-00  
4311-0068-00  
SP-KFA1007  
See below  
3531-0007-00  
3541-0020-00  
3541-0020-00  
SP-KFA1003  
4343-0016-00  
3431-0010-00  
3311-0002-00  
SP-KFA1009  
4349-0017-00  
4342-0009-00  
4329-0013-00  
3341-0017-00  
See below  
3970-0029-00  
3820-0143-00  
3121-0357-00  
4331-0022-00  
3541-0022-00  
4321-0038-00  
See SP-KFA1000  
RMC-KFA170TDLX  
2151-0011-00  
2156-0022-00  
3231-0123-00  
3221-0063-00  
3231-0122-00  
2155-0010-00  
2151-0014-00  
3231-0120-00  
3231-0121-00  
3713-0022-00  
3131-0182-00  
3712-0013-00  
3980-0031-00  
3341-0004-00  
2153-0001-00  
4319-0015-00  
2152-0074-00  
3131-0159-00  
4311-0068-00  
SP-KFA1007  
See below  
3531-0007-00  
3541-0020-00  
3541-0020-00  
SP-KFA1004  
4343-0016-00  
3431-0010-00  
3311-0002-00  
SP-KFA1009  
4349-0017-00  
4342-0009-00  
4329-0013-00  
3341-0017-00  
See below  
3970-0033-00  
3820-0143-00  
3121-0357-00  
4331-0022-00  
3541-0022-00  
4321-0038-00  
See SP-KFA1000  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
Fuel Gauge  
Fuel Gauge Cap  
Fuel Cap Filter  
Fuel Cap  
Fuel Filter Assembly  
Shell Lower Assembly  
Bushing Grommet(S)  
Bushing Grommet(L)  
Twist Lock Stand Off  
Nut Clip  
Cord Bushing  
Power Cord  
Air Line  
Temperature Limit Control  
Flange Screw  
Combustion Chamber  
Photocell Bracket  
Screw-BH  
Photocell Assembly  
Burner Head Assembly  
Burner Head  
17  
18  
19  
20  
21  
21-1  
21-2  
21-3  
21-4  
21-5  
21-6  
21-7  
21-8  
21-9  
21-10  
21-11  
22  
Nipple(Air)  
Nipple(Fuel)  
Nozzle  
Nozzle Seal Washer  
Nozzle Seal Spring  
Nozzle Sleeve  
Spark Plug  
Fiber Washer  
Spring Washer  
Flange Bolt  
Fuel Line  
Motor and Pump Assembly  
Motor  
Capacitor  
Motor Supportor  
Lock Nut.  
Pump Body  
Bolt-PH  
23  
23-1  
23-2  
23-3  
23-4  
23-5  
23-6  
23-7  
Insert  
19  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEVER LEAVE THE HEATER  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
UNATTENDED WHILE BURNING!  
17. PARTS LIST (WHEELS AND HANDLE)  
1) RMC-KFA65TDLX MODEL  
PART NO.  
KEY NO.  
DESCRIPTION  
RMC-KFA120TDLX  
SP-KFA1000  
RMC-KFA170TDLX  
SP-KFA1000  
Rotor Kit  
Blade  
23-8  
23-9  
23-10  
23-11  
23-12  
23-13  
23-14  
23-15  
23-16  
23-17  
23-18  
23-19  
23-20  
24  
25  
26  
27  
28  
29  
30  
31  
32  
See SP-KFA1000  
3531-0008-00  
3541-0020-00  
4329-0014-00  
See SP-KFA1005  
See SP-KFA1005  
SP-KFA1005  
3221-0029-00  
See SP-KFA1006  
See SP-KFA1006  
SP-KFA1006  
4319-0015-00  
2154-0004-00  
4323-0004-00  
3740-0049-01  
3221-0051-00  
39E0-0025-00  
4311-0024-00  
3111-0220-00  
3111-0223-00  
3211-0020-00  
215A-0023-00  
SP-KFA1018  
3231-0111-01  
3211-0022-00  
3131-0348-00  
3221-0059-01  
39A0-0044-00  
3211-0024-00  
See SP-KFA1000  
3531-0008-00  
3541-0020-00  
4329-0014-00  
See SP-KFA1005  
See SP-KFA1005  
SP-KFA1005  
3221-0029-00  
See SP-KFA1006  
See SP-KFA1006  
SP-KFA1006  
4319-0015-00  
2154-0007-00  
4323-0004-00  
3740-0049-01  
3221-0051-00  
39E0-0025-00  
4311-0024-00  
3111-0221-00  
3111-0224-00  
3211-0020-00  
215A-0023-00  
SP-KFA1018  
3231-0111-01  
3211-0022-00  
3131-0348-00  
3221-0059-00  
39A0-0044-00  
3211-0024-00  
PART NO.  
KEY  
DESCRIPTION  
QTY  
End Pump Cover  
Nipple(Air)  
Flange Bolt  
NO.  
1
RMC-KFA65TDLX  
3231-0125-00  
Handle  
1
1
1
2
Cord Wrap  
Hardware Kit  
3231-0056-00  
Lint Filter  
3
HW-KFA1001  
Output Filter  
Filter Kit  
End Filter Cover  
Ball  
2) RMC-KFA120T/170TDLX MODELS  
PART NO.  
Spring  
KEY NO.  
DESCRIPTION  
QTY  
RMC-KFA120TDLX  
RMC-KFA170TDLX  
Plug/Pump Adj.Kit  
Flange Screw  
Fan Assembly  
Set Screw  
Pressure Gauge  
Fan Guard  
1
2
Handle Front  
Handle  
3551-0039-00  
3551-0040-00  
1
1
1
1
2
2
1
4
4
2
2
2
3231-0126-00  
3231-0126-00  
3
Cord Wrap  
Wheel Axle  
Wheel  
3221-0057-00  
3221-0057-00  
4
3541-0064-00  
3541-0064-00  
5
2156-0026-00  
2156-0026-00  
Ignitor  
Screw-PH2  
6
Wheel Cap  
Hardware Kit  
Screw(A)  
Screw(B)  
Flat Washer  
Cotter Pin  
Bushing  
3231-0100-00  
3231-0100-00  
7
HW-KFA1008  
HW-KFA1008  
Shell Upper Front  
Shell Upper Rear  
Shell Cover  
Main P.C.B Assembly  
Fuse  
Thermostat Control Knob  
Side Cover(R)  
BRACKET SIDE COVER  
RATING PLATE  
Power Switch  
Side Cover(L)  
7-1  
7-2  
7-3  
7-4  
7-5  
-
-
-
-
-
-
-
-
-
-
33  
33-1  
33-2  
34  
35  
36  
37  
38  
ACCESSORIES  
Air Pressure Gauge  
Thermostat  
SP-KFA1011 (all models)  
SP-KFA1010 (all models)  
FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR  
CONTACT US AT:  
Phone : 1-800-668-5323  
21  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cognitive Solutions All in One Printer A776 User Manual
Cognitive Solutions Label Maker EZLP UG00000 User Manual
Coleman Camper 2000004679 User Manual
Coleman Fire Pit 5071 Series User Manual
Compaq Personal Computer dc7700 User Manual
Craftsman Lawn Mower 1072777 User Manual
Cub Cadet Snow Blower 421R User Manual
Dixon Lawn Mower 1856 0599 User Manual
Extron electronic Projector Accessories PCM 240 User Manual
Fisher Price Baby Toy 77457 User Manual