Extron electronic Projector Accessories PCM 240 User Manual

PCM 240 • Installation Guide  
IMPORTANT SAFETY INSTRUCTIONS  
Read all instructions before starting installation.  
When using this accessory, basic precautions should always be followed, including the following:  
WARNING: Risk of Personal Injury. Maximum setup load for the PCM is 50 lbs (22.7 kg).  
SAVE THESE INSTRUCTIONS  
NOTE: Refer to local building standards and codes to verify that the installation will meet the regulatory requirements.  
Observe all local and national building and safety codes, UL requirements, and ADA accessibility guidelines.  
WARNING: Risk of Personal Injury and property damage. Do not exceed specified weight limits of any component of  
the installation. Follow the manufacturer's specifications and installation instructions.  
The Extron PCM 240 Drop Ceiling Projector Mount is used for hanging  
PoleVault® System AV products and various projectors.  
Base  
Plate  
The PCM is installed above the drop ceiling and secures the adjustable  
pipe in a pass-through pipe adapter plate. The pipe then supports the  
mounting of the Extron PMK 550 and UPB 25 projector bracket.  
1-gang and 2-gang Accessory Mounting  
Points (for Power Sockets, for example)  
Pipe  
Adapter  
The key components of the PCM 240 are shown in figure 1.  
Also included in the kit are:  
4 turnbuckles, 5 lag eye bolts, 5 concrete anchors, 2 cable clamps,  
1 safety wire – 15 feet, 2 tie wires – 30 feet, 4 T-frame screws, 4  
adhesive pads, escutcheon ring.  
Pipe Adapter Plate  
Lock Nuts (4)  
T-frame  
Securing  
Screws (4)  
Pipe Adapter  
Set Screws (2)  
Pre-Installation  
Determine the exact location of the installation on the drop ceiling.  
Consider the following:  
The vertical and horizontal offsets of the projector from the proposed  
location.  
The projector dimensions relative to the image target.  
NOTE: See the projector manual for details.  
Installation  
Step 1 — Mark the Frame and Cut the Ceiling Tile.  
Figure 1. PCM 240 Parts  
a. At the location for the projector, identify the ceiling tile and T-frame  
where the PCM will be installed.  
b. Remove the predetermined ceiling tile and mark the maximum and  
minimum throw distances of the projector on the T-frame (see  
figure 2).  
X"  
Projector  
Front  
TIP: Mark the screen direction on the back of the tile to  
help with orientation of the tile when replacing it after  
cutting�  
Y"  
T-frame  
c. Place the PCM base plate over the T-frame, between the two marks.  
Lightly tighten the T-frame securing screws.  
Minimum and  
Maximum  
Throw Distance Marks  
d. Mark the location of the PCM base plate on the T-frame to aid in  
replacing it in the correct location.  
e. Measure the distances X and Y (see figure 2) from the inner vertical  
section of the front and left T-frame runners to the center of the  
Pipe Adapter Plate.  
Figure 2. Minimum and Maximum  
Throw Distances  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
f. Loop the safety cable through the center anchor or lag eye bolt,  
attach it to the plate center holes (figure 6) and secure it with the  
cable clamps.  
Secure PCM to frame  
(from either side)  
PCM  
g. Cut appropriate lengths of the supplied tie wire.  
Loop the wire through the anchors or lag eye bolts and the  
turnbuckles, then twist the wire around itself at least five times.  
T-frame  
h. Tighten the turnbuckles by hand (see figure 6), and level the plate  
so that it just rests on the grid.  
ATTENTION: Potential Damage to Property.  
• The four hanging wires should be taut, taking  
the full weight of the completed installation.  
• Overtightening the turnbuckles could cause  
the T-bar assembly to be lifted, making the  
suspended ceiling bowed and unsafe.  
Adjust the turnbuckles to take  
up any slack in the hanging wire.  
Figure 6. Adjust the Turnbuckles.  
j.  
Tighten the four T-frame securing screws on the PCM.  
Step 4 — Final Installation.  
The PCM 240 comes with a threaded pipe adapter installed in the adapter  
plate. This allows for an Extron PMP projector mounting pole to be fitted.  
To fit the mounting pole, do the following:  
a. Back out the set screws on the pipe adapter/adapter plate assembly.  
b. Screw the pole into the adapter. A minimum of three full turns is  
required to safely secure the pole in place  
c. Secure the pole in place by tightening down the set screw on the  
pipe adapter/adapter plate assembly. Cabling for the projector can  
be accessed through the cut-out in the PMP pole.  
d. Other optional accessories can also be installed at this point. These  
include the Extron PMK 350, a low profile, two product mounting  
kit, and the UPB 25, a Universal Projector Mounting Bracket suitable  
for most projectors weighing up to 25 pounds.  
e. Complete any further device installation according to the relevant  
device manual.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PCM 240 • Installation Guide (Continued)  
Specifications  
General  
Maximum load capacity������������������ 50 lbs (22�7 kg)  
Material ����������������������������������������� Steel plate, Tie wire: steel, 14 AWG, 70,000 psi tensile strength  
Dimensions  
Base plate������������������������������� 25�8” L x 8�0” W x 1�2” D (65�5 cm L x 20�3 cm W x 2�9 cm D)  
Product weight������������������������������� 5�6 lbs (2�5 kg  
Shipping weight���������������������������� 9 lbs (5 kg)  
Vibration��������������������������������������� ISTA 1A in carton (International Safe Transit Association)  
Regulatory compliance  
Safety������������������������������������� CE; c-UL, UL for use with UL Listed mount and projector; OSHPD anchorage pre-approval  
Warranty��������������������������������������� 3 years parts and labor  
NOTE: Specifications are subject to change without notice.  
25.80 [655.32]  
2X 14.612 [371.14]  
9.125 [231.78]  
2X 8.500 [215.90]  
1.15 [29.21]  
4X Ø.19 [Ø4.78] THRU  
2X .563 [14.288]  
2X .50 [12.70]  
2X .563 [14.288]  
2.50 [63.51]  
.60 [15.24]  
2X 1.00 [25.40]  
3.00 [76.20]  
2.00 [50.80]  
8.00 [203.20]  
2X 7.000 [177.800]  
6.80 [172.72]  
2X 6.00 [152.40]  
2.00 [50.80]  
2X 10-32 UNF - 2B  
EXTRUDED .13 [3.18]  
2X R1.063 [R26.99]  
4X R.107 [R2.71]  
2X .12 [3.00]  
4X Ø.31 [Ø7.95] THRU  
2X 11.187 [284.15]  
16.331 [414.80]  
2X 1.47 [37.33]  
(1.13 [28.58])  
4.531 [115.09]  
2X .39 [9.86]  
BOTH SIDES  
3X .260 [6.604] X .500L [12.700]  
OBROUND  
23.40 [594.36]  
2X 1.13 [28.58]  
2X .70 [17.78]  
2X 1.00 [25.40]  
3X Ø.266 [Ø6.76] THRU  
.14 [3.48]  
23.67 [601.32]  
Figure 7. PCM 240 Dimensions  
68-1180-01  
Rev D  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
08 12  

Cisco Systems Network Hardware OL 15491 01 User Manual
Compaq Network Router 99875320 5 User Manual
Conair Plumbing Product CL 79 User Manual
Creative Speaker T20 Series II User Manual
Ecom Instruments Cell Phone Ex Handy 05 User Manual
Extron electronic Network Card HSA 800 User Manual
Extron electronic Stereo Receiver P N 26 177 01 User Manual
Fender Mixer SRM 6302 User Manual
GE Toaster 0681131691574 User Manual
GE Ventilation Hood ZV421 User Manual