FEATURES
Heavy-duty 14 gauge steel heat exchanger with a
long lasting ceramic fiber combustion chamber
Ducane Oil Furnace
Easy access large diameter clean out ports in heat
exchanger
RLHF-R80C
Foil-faced high density fiberglass insulation in cabinet
reduces heat loss and sound
Cabinet has pre-painted steel for maximum durability
Slide-out blower design for easey cleaning and
service
Multi-speed direct drive blower assembly allows the
airflow to be matched to the application requirements
Dynamically balanced blower with resilient motor
mounts for smooth and quiet operation
Includes barometric damper
High efficiency air flow system to provide consistent
operation through all operating conditions
Honeywell 7184B primary control with 15 second pre
purge, interrupted ignition, limited reset, and LED
diagnostics
PSC burner motor with low amp draw and ball
bearings for long life
40 VA transformer (Direct drive only)
Limited life-time warranty on heat exchanger and five
year limited warranty on all parts
C
Download from Www.Somanuals.com. All Manuals Search And Download.
Blower Performance
Motor
Size
(hp)
Temp.
Rise
oF
CFM @ ext. static pressure - in w.c.
Blower
Size
Blower
Speed
Model
.20
.30
.40
.50
.60
.70
.80
.90
High
Med High 1,340
Med
Low
High
1,410
1,320
1,282
1,175
1,037
1,995
1,750
1,482
1,280
1,190
1,092
975
1,950
1,690
1,430
1,195
1,100
1,015
900
1,900
1,630
1,388
1,090
1,016
918
1,000
900
845
850
801
732
790
680
600
RLHF80C84/95D12
1/2 10 x 8 45-75
1,236
1,090
2,072
855
771
665
547
1,850
1,585
1,320
1,700
1,495
1,257
1,650
1,380
1,160
1,500
1,299
1,066
Med High 1,794
RLHF80C112/125D20 3/4
12 x 9 45-75
Med
Low
High
1,515
1,355* 1,326* 1,290* 1,233* 1,176* 1,109* 1,045* 1,000*
1,406
1,341
1,206
981
1,274
1,156
948
1,203
1,090
906
1,126
1,012
842
1,011
922
774
650
997
931
847
754
915
816
687
561
871
798
734
640
784
684
541
406
740
672
597
503
Med High 1,256
RLHR80C57/72D12
RLHR80C84/95D12
1/3 10 x 8 45-75
1/2 10 x 10 45-75
Med
Low
High
1,010
837
1,487
818
798
761
716
1,398
1,303
1,170
1,022
2,141
1,750
1,504
1,303
1,220
1,108
970
2,082
1,706
1,480
1,210
1,150
1,000
909
2,000
1,649
1,440
1,104
1,033
935
Med High 1,380
Med
Low
High
1,230
1,057
2,218
835
1,907
1,579
1,380
1,797
1,489
1,320
1,711
1,408
1,251
1,590
1,324
1,174
Med High 1,782
RLHR80C112/125D20 3/4
12 x 9 45-75
Med
Low
High
1,552
1,353* 1,335* 1,300* 1,277* 1,223* 1,170* 1,074* 1,004*
2,560
2,500
2,030
2,450
1,980
2,390
1,960
2,230
1,870
2,100
1,820
1,940
1,750
1,800
1,635
Med High 2,100
RLHR80C196D24
3/4 12 x 12 60-90
Med
Low
1,580* 1,520* 1,480* 1,433* 1,378* 1,277* 1,175* 1050*
1,369* 1,336* 1,293* 1,231* 1,161* 1,100* 979* 850*
*Not recommended for heating. Temperature rise may be outside acceptable range.
Accessories
Description
Combustible Floor Base
Combustible Floor Base
Clean Brush Out Kit
Used with
RLHF/R84/95
RLHF/R112/125
All models
RLHF84/95
RLHF112/125
RLHF84/95
RLHF112/125
RLHR196
Kit Number
ABASE537-1
ABASE538-1
ABRSH380-3
AVEST547-2
AVEST548-2
AFILT535-1
AFILT536-1
AFILT 561-1
ABOOT571
ACAP570
Vestibule Kit
Vestibule Kit
Filter Kit
Filter Kit
Filter Kit
Combustion Air Kit
All models
All models
All models
All models
Clean Out Cap Kit
Tjernlund Side Wall Vent Kit1
Field Controls Side Wall Vent Kit2
This can be ordered from Tjernlund, part number SSIC.
This can be ordered from Field Controls, part number SWG-5-CK61.
ASVNT522
ASVNT523
1
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions (in.)
Model
A
B
C
D
E
F
G
H
J
K
L
M
N
P
3
3
Q
53
R
3
S
RLHF80C84/95D12 59 20 1/2 20 1/2 18 1/4 18 1/4 1 1/4 1 1/4 18 18 1 1/4 1 1/4 32 1/2 10 1/4
RLHF80C112/125D20 59 23 1/2 23 1/2 21 1/4 21 1/4 1 1/4 1 1/4 21 21 1 1/4 1 1/4 32 1/2 11 3/7
14 1/2
53 4 3/4 14 1/2
53 14 1/2
53 4 3/4 14 1/2
RLHR80C57/72D12
59 20 1/2 20 1/2 18 1/4 18 1/4 1 1/4 1 1/4 18 18 1 1/4 1 1/4 32 1/2 10 1/4
RLHR80C84/95D12
3
3
RLHR80C112/125D20 59 23 1/2 23 1/2 21 1/4 21 1/4 1 1/4 1 1/4 21 21 1 1/4 1 1/4 32 1/2 11 3/7
3
RLHR80C196D24 67 26 1/4 26 1/4 23 1/2 23 1/2 1 3/8 1 3/8 24 24 1 1/8 1 1/8 36 5/16 13 1/8 15 50 20 3 1/8
Clearances (in.)
Horizontal
Counterflow
Model
Front Above Rear Flue Bottom
Model
Front Above Rear Flue
RLHF80C84/95D12
RLHF80C112/125D20
RLHR80C57/72D12
RLHR80C84/95D12
RLHR80C112/125D20
RLHR80C196D24
24
1
1
7
1
RLHF80C84/95D12
RLHF80C112/125D20
RLHR80C57/72D12
RLHR80C84/95D12
RLHR80C112/125D20
16
0
1
7
24
1
1
7
1
24
1
1
7
All specifications and illustrations
subject to change without notice and
without incurring obligations..
For more information, contact your local Ducane distributor.
Form No. DRLHF-R80C-100 (7/06)
Printed in U.S.A.
©Allied Air Enterprises, A Lennox International company 2006
*DRLUF80C-100-7-06*
Download from Www.Somanuals.com. All Manuals Search And Download.
|