Delta Electronics Power Supply S48SS User Manual

Delphi Series S48SR and S48SS  
Evaluation Procedure  
Delta Delphi Series 48Vin  
S48SR and S48SS  
The Delphi Series S48SR and S48SS,  
48V input, single output, isolated DC/DC  
converters are the latest offering from one  
of the world’s largest power supply  
manufacturers Delta Electronics, Inc.  
With creative design technology and  
optimization of component placement,  
these converters possess outstanding  
electrical and thermal performance, as well  
as extremely high reliability under highly  
stressful operating conditions. All models  
are protected from abnormal input/output  
voltage and current conditions. An  
encapsulated version is available for the  
most robust performance in harsh  
environments.  
1.0 Purpose  
This document guides the user to perform  
electronic measurements on  
S48SR, 15W or a S48SS, 15W DC/DC  
converter using the Delta Evaluation Board.  
a
Delphi  
2.0 Relevant Documentation  
This document guides the user through the  
evaluation procedures to qualify a Delphi  
module. The data shown in this Evaluation  
Procedure is for the 3.3V unit. Please refer  
to the appropriate technical data sheet for  
detailed performance and technical  
information for Delphi units with different  
output voltages.  
The document and general knowledge listed  
below is relevant to this evaluation  
procedure:  
2.1 S48SR or S48SS Series Applicable  
Data Sheet  
2.2 2”×1” Power Module Evaluation Board  
Schematic  
2.3 2”×1” Power Module Evaluation Board  
Layout  
2.4 General Test and Safety Procedures  
2.5 ESD Protection  
Evaluation Procedure  
EP_SP  
Version X1.0  
1
November 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Delta Electronics, Inc.  
5.0 Thermal of the Converter  
It is imperative that sufficient airflow be provided to the converter at all times during all  
portions of testing. Please refer to the applicable data sheet for the proper cooling and  
derating necessary to achieve accurate results when testing the converter.  
6.0 Tests Performed  
The following tests are performed at room temperature +25 C.  
6.1 Input Characteristics  
Input Voltage Range  
Under Voltage Lockout  
No Load Input Current  
Disable Input Current (applies to S48SS version only)  
6.2 Output Characteristics  
Line Regulation  
Load Regulation  
Output Regulation  
Output Overvoltage Protection  
6.3 Dynamic Characteristics  
Maximum Output Voltage Deviation (due to step change in load)  
Response time (due to step change in load)  
Soft Start Turn-On Time  
6.4 Thermal Characteristics  
Efficiency  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
7.0 Test Set-Up  
7.1 Initial Set-Up  
1) Examine the part number of the power module to determine of the unit is defined  
for positive or negative logic enable as follows:  
S48SS3R304NR would denote negative logic, while S48SS3R304PR would  
denote positive logic (S48SS only).  
2) If the power module has positive logic, switching SW1 to position HI or floating will  
enable the power converter. Switching SW1 to position Low will disable the power  
converter.  
3) If the power module has negative logic, switching SW1 to position Low will enable  
the power converter. Switching SW1 to position HI or floating will disable the power  
converter.  
4) Multimeters (1)  
Multimeters (2 and 3)  
5) Scope  
Ampere / Autorange  
Voltage / Autorange  
Timebase  
Trigger  
10 mS  
Auto  
Channel (1)  
Volts / Div  
Coupling  
10V  
DC  
Channel (2)  
Volts / Div  
Coupling  
1V  
DC  
6) Electronic Load  
Turn on the Electronic Load and adjust the current level. The total output current is  
4.5A (15W) for the S48SR power module and 4.5A (15W) for the S48SS power  
module. Ensure the output load does not exceed the recommended maximum  
current.  
7) SW2 is used for trimming the output voltage. Turn SW2 to the OFF position if the  
function is not being used. Turn SW2 to the UP position if trimming up is required.  
Turn SW2 to the DOWN position if trimming down is required.  
7.2 Initial Power Up  
1) Turn the Power Supply on and increase the input voltage (use DVM2 to monitor the  
voltage) until it reaches 48V (or the desired value).  
2) Toggle SW1 to the appropriate logic position to turn the power module on (S48SS  
only).  
3) The converter is now operating, which can be verified by observing the DVM3  
(approximately 3.3V.) and Channel 2 of the oscilloscope (+3.3V output).  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
4) The converter may also be turned on by switching SW1 to the appropriate logic  
enable position and ramping the voltage manually or turning on the Power Supply  
with a preset output voltage (S48SS only).  
5) Toggle SW1 to the “OFF” position after performing each test (S48SS only).  
8.0 Test and Evaluation  
8.1 Input Characteristic  
8.1.1 Input Voltage Range  
The Delphi S48SS3R304NR and S48SR3R304ER DC/DC converters will operate at  
full load from 36Vin to 75Vin, steady state. The converter features input under-  
voltage protection which will not allow the converter to start up unless the input  
voltage exceeds the turn-on voltage threshold.  
Test  
1)  
2)  
Turn on the fan.  
Set the enable switch SW1 to the appropriate logic enable position (defined in  
Section 7.1. S48SS only).  
3)  
4)  
Set the input voltage to desired operating point while monitoring DVM2.  
Test the input under voltage circuit while observing DVM2, DVM3 and Channel  
1, Channel 2 of the oscilloscope. Increase the input voltage until the output of  
the converter reaches stability (3.3 volts.) This will occur between 33.8 and 35.8  
volts (please refer to the datasheet for the detailed specification).  
8.1.2 No Load Input Current  
Test  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position (S48SS only).  
3) Set the input voltage to desired operating point while monitoring DVM2.  
4) Remove the electronic or the resistive load (output load)  
5) Note the input current from DVM1.  
6) The following is the result of the No load Input Current of the DC/DC converter.  
The No Load Input Current will be around 25 mA (please refer to the datasheet for  
the detailed specification).  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
8.1.3 Input Current Module Off (S48SS only)  
Test  
1) Set the enable switch SW1 to the appropriate logic enable position to disable the  
power supply (as defined in Section 7.1).  
2) Adjust the input power supply to the desired operating point of interest while  
monitoring DVM2.  
3) Note the input current from DVM1.  
4) This reading is the result of the Disable Input Current of the DC/DC converter.  
The Disable Input current will be around 1 mA (please refer to the datasheet for the  
detailed specification).  
8.2 Output Characteristic  
8.2.1 Line Regulation  
Line Regulation is defined as the percentage change in output voltage caused by  
varying the input voltage over the specified range (36 to 75 volts) while the output load  
and temperature remain constant.  
Test  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position (S48SS only).  
3) Set the output power to the desired operating point.  
4) Adjust the input voltage across the converter’s input range (36 to 75 volts) while  
monitoring DVM3.  
5) Note the maximum +/- deviation of the output voltage over the full range of the  
input operating voltage.  
8.2.2 Load Regulation  
Load Regulation is defined as the percentage change in output voltage caused by  
varying the output load current over the specified range (no load to full load) while the  
input voltage and temperature remain constant.  
Test  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position (S48SS only).  
3) Set the input voltage to the desired operating point.  
4) Adjust the output load across the converter’s operating load range (no load to full  
load).  
5) Note the maximum +/- deviation of the output voltage over the full range of the  
operating load range.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
8.2.3 Output Ripple  
Output Ripple is defined as the periodic AC component at the DC/DC converters  
output voltage. The output ripple is measured in Peak to Peak and RMS values, both  
done with a specific bandwidth.  
Test  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position.  
3) Adjust the input voltage and output load to the desired operating point (S48SS  
only).  
4) Adjust Channel 2 on the oscilloscope to be AC coupled @ 2uS / Div and 50mV/Div  
to use the 20 MHz bandwidth of the scope.  
5) The output ripple of the DC/DC converter is measured at full load operating power.  
8.3 Dynamic Characteristics  
8.3.1 Output Voltage Deviation  
Output Voltage Deviation is defined as the response of the converter to a sudden step  
change in the output load current. The output voltage deviation is characterized by two  
important parameters: Maximum Output Voltage Deviation and Response Time, which  
is the length of time that the output voltage takes to return to 1% of its specified value  
(please refer to the datasheet for the detailed specification).  
Test -S48SS & S48SR  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position (S48SS only).  
3) Adjust the input voltage to the desired operating point.  
4) Set Channel 2 on the oscilloscope to be AC coupled and to 50mV/Div and  
5mS/Div. Set the trigger to auto and adjust the trigger point for a negative going  
pulse.  
5) Set the Electronic Load in dynamic mode and set it for the desired load transient.  
6) Measure the positive Peak or negative Peak deviation and response time of the  
output voltage during the load transient.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8.3.2 Soft Start Turn-On Time  
Soft Start Turn-On Time is defined as the time it takes for the output to rise to within  
95% of its final value from the time when the converter is enabled. The rise time is  
deliberately made slower to reduce the inrush current and to eliminate any overshoot  
in the output voltage.  
Test -S48SR & S48SS ( turn on the module by using the input power supply)  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position (S48SS only).  
3) Turn on the input Power Supply and set it to the desired operating point.  
4) Set the input Power Supply disable by an external switch or use the input Power  
Supply internal disable function.  
5) Set Channel 1 on the oscilloscope to be DC coupled and to 1V/Div.  
6) Connect a coaxial cable from Channel 1 to BNC2 on the Evaluation Board.  
7) Set Channel 2 on the oscilloscope to be DC coupled and to 20V/Div.  
8) Connect a coaxial cable from Channel 2 to BNC1 on the Evaluation Board.  
9) Set the Timebase to 10 mS/Div.  
10) Set the Trigger for a one time event and set the Trigger level at approximately 2V  
on Channel 1.  
11) Enable the input Power Supply to supply power and record the waveforms on the  
oscilloscope.  
Test-S48SS (turn on the module by using the Remote on/off feature)  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic disable position.  
3) Turn on the input Power Supply and set the input voltage to the desired operating  
point.  
4) Set Channel 1 on the oscilloscope to be DC coupled and to 1V/Div.  
5) Connect a coaxial cable from Channel 1 to BNC2 on the Evaluation Board.  
6) Set Channel 2 on the oscilloscope to be DC coupled and to 2V/Div.  
7) Set the Timebase to 10 mS/Div.  
8) Set the Trigger for a one time event and set the Trigger level to approximately 2V  
on Channel 2.  
9) Connect the 10X probe (Channel 2) to the “ON/OFF” test point on the evaluation  
board and connect the ground clip to the “Vin –“ pin on the evaluation board.  
10) Set the enable switch SW1 to the appropriate logic position to enable power and  
record the waveforms on the oscilloscope.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: Different electronic loads may have dramatically different results because of  
their input characteristics during Turn-On. If the Turn-On appears abnormal, replace  
with an actual resistive load of appropriate value.  
The Soft Start Turn-On Time of the converter provided in the Evaluation Kit was  
measured with the Electronic Load set at 4.5A.  
8.4 Thermal Characteristics  
8.4.1 Efficiency  
Efficiency is the ratio of total output power to the input power. It is typically measured  
at full load and nominal input voltage.  
Test  
1) Turn on the fan.  
2) Set the enable switch SW1 to the appropriate logic enable position (S48SS only).  
3) Adjust the input voltage to the desired operation point.  
4) Set the Electronic Load to the desired operating point..  
5) Read and note the +3.3 output voltage (DVM3) and input voltage (DVM2).  
6) Read and note the input and output currents from the DVM1 and the Electronic  
Load.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
7) Use the following formulas to calculate the efficiency:  
Efficiency= (Pout/Pin) × 100(%)  
Pin = Iin × Vin  
Pout = Iout × Vout  
The following graph shows the efficiency results of the S48SS/S48SR  
converters measured at different operating points.  
90  
85  
80  
75  
70  
65  
60  
36Vin  
48Vin  
55  
75Vin  
50  
0.5  
1
1.5  
2
2.5  
3
3.5  
4
4.5  
OUTPUT CURRENT (A)  
Appendix A- Evaluation Board Schematic  
SVin+  
COPPER  
L1  
VIN+  
VIN+  
VOUT+  
TRIM  
VOUT+  
BNC2  
NC  
BNC1  
C2  
NC  
C3  
68u/100V  
C101  
NC  
C102 C103 C104 C107 C108 C109  
NC NC NC NC NC NC  
C110  
NC  
C105 C106  
1u/25V 10u/25V  
VIN-  
VIN-  
VOUT-  
VOUT-  
SVin-  
J2  
NC  
J3  
0
R1  
NC  
R3  
NC  
VR1  
100K  
SW1  
1
Hi  
ON/OFF  
Floating  
2
DOWN  
3
NC  
OFF  
2
SW2  
NC ZD1  
Low 3  
NC C1  
1
UP  
J1  
R2  
NC  
VR2  
100K  
NC  
J4  
0
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B - Evaluation Board Layout (Top View)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C- Evaluation Board Layout (Bottom View)  
CONTACT DATA: www.deltaww.com  
USA:  
Europe:  
Asia:  
Telephone:  
Telephone:  
Telephone: +886 3 4526107 x6202  
Fax: +886 3 4331707  
East Coast: (888) 335 8201  
West Coast: (888) 335 8208  
Fax: (978) 656 3964  
France: +33 1 6485 1212  
Germany: +49 89 370 62 897  
UK: +44 777 195 6299  
Fax: +33 1 6485 1212  
Warranty  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is  
available upon request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by  
Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its  
use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves  
the right to revise these specifications at any time, without notice.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Compaq Network Router uSign 100 User Manual
Crosley Radio Turntable CR40 User Manual
Cuisinart Fryer 3 in 1 Multicooker User Manual
Curtis Beverage Dispenser FRW153 User Manual
Danby Freezer DCF1014WE User Manual
Dell Server C6105 User Manual
Euro Pro Frozen Dessert Maker KP160E User Manual
Extron electronic Speaker SF 228T User Manual
GE Double Oven EER2000 User Manual
Global Machinery Company Engraver DEC007EN User Manual