Delfield Refrigerator SARRT1 S User Manual

®
Project __________________________________  
Item ____________________________________  
Quantity ________________________________  
CSI Section 11400  
Delfield  
Approved _______________________________  
Date ____________________________________  
Specification Line®  
Self-Contained Solid Door Refrigerated Roll-Thru  
Models  
One section Two section Three section  
SSRRT1-S  
SARRT1-S  
SMRRT1-S  
SSRRT2-S  
SARRT2-S  
SMRRT2-S  
SSRRT3-S  
SARRT3-S  
SMRRT3-S  
Stainless exterior and interior full door  
Stainless exterior and aluminum interior full door  
Stainless front aluminum exterior and interior full door  
Options &  
Standard Features  
Stainless steel interior and exterior (SS)  
Stainless steel exterior, aluminum  
interior (SA)  
Accessories  
Security (prison) package  
Door field rehingability  
Laminate on front, sides and  
back  
Aluminum interior and exterior, stainless  
front (SM)  
Built in door locks with heavy duty  
strikes  
Bottom mount electrical  
Stainless steel banking strip  
Heat shield end  
230-50-1 electrical  
220-60-1 electrical  
Recessed metal door handle  
Pressure relief valve is standard to  
prevent door vapor lock  
Exterior digital thermometer with high/  
low temperature alarm  
Easy to use electronic control  
Easy access “flip upshroud  
Tough ABS interior door liners  
10attached cord and plug on 115V units  
Stainless steel breaker strips  
High density foamed in place  
environmentally friendly, Kyoto Protocol  
Compliant, Non ODP (Ozone Depletion  
Potential), Non GWP (Global Warming  
Potential) polyurethane keeps energy  
costs low  
Energy savings door heater switch  
Two year parts & labor warranty  
Five year compressor warranty  
SSRRT1-S  
Specifications  
Exterior: SS and SA models shall have corrosion resistant stainless  
steel exterior cabinet sides, front and shroud. SM models shall have  
corrosion resistant aluminum on exterior cabinet sides and will have  
stainless front and shroud. All units shall have the upper shroud  
hinged with a gas assist stay open feature to provide easy access to  
the refrigeration system.  
impacting aisle space. Keyed door lock is mounted in the door next  
to the handle. Lock engages into a heavy duty strike mounted to  
the cabinet face. Door gaskets are magnetic and mount to the door  
snapping in place and are removable without tools.  
Refrigeration system: All components are mounted to the exterior  
of the cabinet ceiling, outside the food zone and are assembled  
as one piece and can be removed as one piece. Environmentally  
friendly R404A refrigerant is used. The system has the capability  
of maintaining between 27ºF and 40ºF in heavy use food service  
operations. Refrigerant is metered using a highly responsive  
thermostatic expansion valve. System is controlled using Delfield’s  
ACT-Advanced Control Technology electronic temperature control,  
which provides improved pull down times, reduces compressor  
cycling and longer compressor life with lower energy consumption.  
Interior: Cabinet interior shall be corrosion resistant stainless steel  
(SS models) or heavy gauge aluminum (SA and SM models). Bottom  
and top surfaces shall be die stamped to provide radius corners  
and recessed floor. Mounted to the interior ceiling, the interior  
incandescent light is controlled automatically through a switch  
mounted in the hinge assembly to protect against breakage. Door  
openings are protected with heavy gauge stainless steel breaker  
strips. An air duct shall be mounted to the ceiling assuring low  
velocity, even air movement throughout the cabinet interior.  
Control system uses adaptive defrost to assure evaporator coil is free  
of ice and is operating at optimum efficiency. Evaporator condensate  
is eliminated using an energy efficient hot gas system.  
Each section can accommodate a 28 1/2x 27 1/4x 72cart.  
Doors: Exterior shall be corrosion resistant stainless steel. Interior  
liner shall be resilient high impact ABS material formed to protrude  
beyond the door gasket to protect the gasket from tearing. Each  
door has two edge mount, self closing, cam lift style hinges. Doors  
can be removed from the cabinet without the use of tools. Metal  
door handle shall be recessed into the door for easy grip without  
Electrical: Standard electrical on one and two section units shall  
be 115V, 60 Hz single phase. A 10cord and plug is supplied and  
attached to a junction box mounted on the exterior top of the  
cabinet. Three section units shall be 115/208-230 and will require  
hardwire connections.  
980 S. Isabella Rd.  
Mt. Pleasant, Michigan 48858  
Fax: 800-669-0619  
Phone: 800-733-8948 or 989-773-7981  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Craftsman Lawn Mower 917O251550 User Manual
Craftsman Trimmer 31679191 User Manual
Curtis Clock Radio SCR1384 User Manual
Dell Server 21DXJ User Manual
Delta Electronics Power Supply Series Q48SB User Manual
Dynacord Stereo Amplifier D 12 3A User Manual
Edelbrock Automobile Parts R08364 User Manual
Fisher CRT Television PC 13R90 User Manual
GBC Laminator H410 User Manual
Global Machinery Company Power Hammer DEC004DC User Manual