		 Adorable Humidifiers   
					1 GALLON/ 3.78 LITER   
					ULTRASONIC HUMIDIFIER   
					MODELS # EE-865 – EE-5058   
					PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND   
					EFFECTIVE USE OF THIS APPLIANCE.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				IMPORTANT SAFETY INSTRUCTIONS   
					INTRODUCTION   
					Thank you for purchasing our CRANE Ultrasonic Humidifier. Each unit has been   
					manufactured to ensure safety and reliability. Before using for the first time, please read   
					the instructions carefully, and keep them for further reference.   
					WARNING! READ AND SAVE THESE INSTRUCTIONS. Failure to follow all   
					the instructions listed below may result in electric shock, fire and/or serious personal   
					injury.   
					1. Do not carry water tank by handle when it is filled with water. It is   
					advisable to carry filled water tank with two hands.   
					2. DO NOT operate outdoors; this humidifier is intended for indoor use only.   
					3. Always have water in the water tank when operating the unit.   
					4. Use only clean, cool tap water to fill the tank (filtered or distilled water is   
					recommended to avoid white dust if tap water is too hard). DO NOT use hot water.   
					5. Be sure that the filling cap of the tank is firmly tightened. Always have the mist   
					direction nozzle and the mist chamber in place while the unit is operating. Place the   
					mist direction nozzle so it aims away from children, walls, furniture, and electrical   
					appliances.   
					6. Use only a 110-120VAC outlet. ALWAYS plug and unplug unit with dry hands.   
					7. Never operate the unit with a damaged cord or plug.   
					8. Always place the unit on a smooth, flat, level surface, and away from direct   
					sunlight. Keep the cord away from heated surfaces and areas where it could be   
					walked on or tripped over. Unplug the unit when not in use and whenever you   
					clean or move the unit.   
					9. Do not add medication of any type into the nozzle, base or water tank. Do not   
					cover any openings on the unit or insert objects into any openings.   
					10.The unit should not be left unattended in a closed room as the air could become   
					saturated and leave condensation on walls or furniture. Leave room door partly   
					open.   
					11.When cleaning the inside of the unit keep water away from the air outlet / fan vent   
					(see FIG.3). The exterior may be wiped with a damp cloth, except the electrical   
					controls, only when the unit is off and unplugged. Humidifier requires regular   
					cleaning. Refer to cleaning instructions.   
					12.Do not tilt or tip the unit or attempt to empty or fill it while it is in operation.   
					13.Do not use a detergent to clean any parts of the unit that contain water. Always   
					use a few drops of bleach with water to clean humidifier. Detergent film dissolved   
					in the water supply can interfere with the output of the unit.   
					SAVE THESE INSTRUCTIONS!   
					2 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				GENERAL SAFETY INSTRUCTIONS   
					WARNING! Read and understand all instructions. Failure to follow all instructions   
					listed below may result in electric shock, fire or serious personal injury. The warnings,   
					cautions, and instructions discussed in this instruction manual cannot cover all possible   
					conditions and situations that may occur. It must be understood by the operator that   
					common sense and caution are a factor which cannot be built into this product, but must   
					be supplied by the operator.   
					THIS HUMIDIFIER IS NOT A TOY!   
					Do not let your child play with this appliance. Serious injury and   
					electrocution might be possible. This appliance has to be operated by an adult only.   
					Children should be supervised to ensure that they do not play with the humidifier.   
					SAVE ALL INSTRUCTIONS!   
					CAUTION: A short power supply cord is provided to reduce the risk of personal injury   
					resulting from becoming entangled in or tripping over a longer cord. Extension cords are   
					available from local hardware stores and may be used if care is exercised in their use. If   
					an extension cord is required, special care and caution is necessary. Also the cord must   
					be: (1) marked with an electrical rating of 125 V and at least 13 A., 1625 W., and (2)   
					the cord must be arranged so that it will not drape over the countertop or tabletop   
					where it can be pulled on by children or tripped over accidentally.   
					ELECTRIC POWER   
					If electric circuit is overloaded with other appliances, your appliances may not operate   
					properly. The appliances should be operated on a separate electrical circuit from other   
					operating appliances.   
					POLARIZED PLUG   
					This appliance has a polarized plug (one blade is wider than the   
					other). As a safety feature to reduce the risk of electrical shock, this   
					plug is intended to fit in a polarized outlet only one way. If the plug   
					does not fit fully in the outlet, reverse the plug. If it still does not fit,   
					contact a qualified electrician. Do not attempt to defeat this safety   
					feature.   
					SAFETY WARNING   
					Although your appliance is easy to operate, for your safety, the below warnings must be   
					followed:   
					1. Do not place the appliance near a heat source.   
					2. Never leave the appliance unattended while connected to the electrical outlet.   
					3. To avoid any accidents, never cover the mist when the appliance is in operation.   
					4. Use the appliance on a stable surface away from water.   
					5. Do not unplug from the wall socket by pulling on the supply cord.   
					6. The appliance must be unplugged:   
					A. Before either filling or emptying   
					B. Before any cleaning or maintenance   
					C. After use   
					D. If it appears to be faulty   
					THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY.   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				LIST OF MAIN PARTS   
					Fig. 1 (Central Body)   
					1. Central Body (water basin)   
					2. On/Off Switch   
					3. Power Cord   
					4. Regulator Control Knob   
					5. Humidity Output Indication   
					6. Red/Green Power Light   
					(shape of Central Body depends on   
					model #)   
					Fig. 1   
					Fig. 2   
					Fig. 3   
					Fig. 2 (Top of Water Tank)   
					7. Vapor Outlet Channel   
					8. Water Tank Handle   
					(shape of Tank depends on model #)   
					Fig. 3 (Water Basin)   
					9. Nebulizer   
					10.Vaporization Chamber   
					11.Fan Vent   
					12.Valve Opener   
					13.Water Level Sensor   
					Fig. 4 (Bottom of Water Tank)   
					14.Water Tank Valve   
					15.Water Tank Cap   
					16.Vapor outlet channel   
					Fig. 4   
					Fig. 5 (Water Tank Lid)   
					17.Water Tank Lid   
					18.Vapor Output Slots   
					(shape of Water Tank Lid depends on   
					model #)   
					Fig. 5   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				TECHNICAL SPECIFICATIONS:   
					Rating Voltage   
					Frequency   
					120V   
					60Hz   
					Power   
					32W   
					Water Tank Capacity   
					Approx. 1.0 Gallon / 3.78   
					Liter   
					Output Per 24 Hours   
					Approx. 2.1 Gallon / 8   
					Liter   
					Run Time Per Tank   
					Humidifying Capacity   
					Noise   
					Min. 11 Hours   
					Up to 500 sq.ft. / 46 m2   
					< 36.5 (dB) A   
					CONTENTS OF PACKAGING   
					a. Instruction Manual   
					b. Central Humidifier Body   
					c. Water Tank   
					d. Water Tank Lid with Vapor Output Slots   
					If any of the above items are missing, please contact our service department at 1-888-   
					
					- 4:00pm CT   
					OPERATION AND USE   
					BEFORE EACH USE   
					CHECK HUMIDIFIER PLACEMENT - Place the Humidifier on an elevated non-metallic   
					waterproof surface for best performance. This is to help disperse the mist in the air,   
					and prevent it from being knocked or tipped over.   
					CHECK WATER LEVEL SENSOR - Make sure that the water level sensor is secured   
					properly. Refer to Water Level Sensor on page 9 for instructions on how clean and   
					assemble water level sensor.   
					CHECK FAN VENT   
					This fan vent is located on the bottom of   
					the humidifier. The purpose of the fan   
					vent is to blow the cool mist through the   
					vapor outlet slots. It is important that   
					this part is kept clean and free of   
					obstructions. We recommend checking   
					the fan vent before using this item (i.e.   
					lint, paper).   
					Do not place humidifier on top of a   
					towel, or a carpeted surface. The fan   
					vent on the bottom may become   
					blocked, and overheat the   
					humidifier.   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				CAUTION:   
					DO NOT operate the humidifier without water in the water tank.   
					DO NOT plug or unplug the cord with wet hands; electric shock   
					could happen.   
					ASSEMBLY   
					1. Lift the water tank off the central body.   
					2. Turn over the water tank and unscrew the water tank cap   
					at the bottom of the tank by turning it counterclockwise.   
					(See Fig. 6)   
					Fig. 6   
					3. Fill water tank with cold water; do not fill all the way to   
					the rim.   
					(See Fig. 7)   
					Note: To avoid possible white dust due to hard water it   
					is recommended to use filtered or distilled water.   
					DO NOT use hot water. Use cool tap water.   
					DO NOT add any medication or other additives to the   
					water.   
					Fig. 7   
					DO NOT pour water into Vapor Outlet Channel (Fig. 2 on   
					page 4)   
					4. Replace the water tank cap, aligning the threads on the   
					tank with the threads on the cap, and turn it clockwise.   
					(See Fig. 8)   
					Fig. 8   
					5. Turn the tank over, holding it by the top handle, and   
					place it on the central body, making sure it fits perfectly.   
					Place the water tank cap with output slots on top of the   
					water tank. (see Fig. 9)   
					Note: Do not attempt to move humidifier while water tank is   
					placed on the water basin. Doing so may cause leakage of   
					water. Also do not place humidifier on the floor. Place   
					humidifier on an elevated surface.   
					Fig. 9   
					6. Plug the power cord into a wall socket and turn on the   
					unit. The On/Off switch is located at the back of the unit.   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				7. The Power Light will turn on red. In a few seconds it will switch to green, indicating   
					that enough water is in the water basin, and mist will start emitting through the   
					openings at water tank lid.   
					8. Use the humidity output regulator control knob to adjust   
					the intensity of the mist output. Turning the knob   
					clockwise will increase the moisture output, turning the   
					knob counterclockwise with reduce the moisture output.   
					(see Fig. 10)   
					Note: When at maximum level it is normal to hear a faint   
					dripping sound.   
					Fig. 10   
					9. When the humidifier runs out of water the power light will turn red, and the mist   
					output will stop. This is a safety feature to prevent the humidifier from possibly over   
					heating and damaging the nebulizer. This safety feature uses a water level sensor to   
					stop the nebulizer once the water level sinks below the required level in the water   
					basin. Turn the humidifier off and unplug before removing and refilling the water   
					tank. Please note that the power light on the humidifier body will stay on.   
					The (red) light signal indicates that the humidifier is turned on and needs to   
					be refilled.   
					INSERTING HUMIDIFIER FILTER   
					(SOLD SEPARATELY not included with your humidifier)   
					A humidifier filter is an optional accessory for your Crane Cool Mist Humidifier.   
					Filters are used to eliminate white dust caused by hard water and to reduce   
					mold spores and bacteria that can build up in your humidifier.   
					Place humidifier filter in humidifier as shown in Fig. 10A   
					NOTE: Do not leave filter in humidifier longer than   
					recommended time. See filter instructions on filter box   
					packaging.   
					Filters are not included with the humidifier and can be   
					purchased separately.   
					Fig. 10 A   
					SET THE CORRECT HUMIDITY OUTPUT   
					Adjust the mist control so that the mist   
					rises up and gets absorbed by the room   
					air. Do not turn on too high an output   
					as the mist cannot be absorbed by the   
					air and accumulates on the surface   
					around the humidifier.   
					If the humidifier is placed near a fan or   
					air conditioning outlet the mist may be   
					forced down by the foreign air stream.   
					Change the location of the humidifier or   
					reduce the output of the other room   
					correct   
					wrong   
					conditioning appliances.   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				A NOTE ABOUT HUMIDITY   
					 
					 
					It is best to keep the humidity level at about 30-50 percent of relative humidity.   
					The comfort level of humidity will vary from room to room and with changing room   
					conditions.   
					 
					 
					 
					In cold weather, windows and even some walls may fog or develop frost from   
					excessive indoor humidity. If this occurs, reduce the mist intensity setting to avoid   
					damage from condensed water dripping on windowsills.   
					Too much humidity in the room may allow moisture to accumulate on surfaces where   
					bacteria and fungi can grow. Moisture that gathers may also damage furniture and   
					walls, especially wallpaper.   
					To eliminate excessive humidity, especially in small rooms, leave the room door open   
					and adjust the mist intensity control setting.   
					MAINTENANCE   
					CAUTION:   
					Always be sure that the appliance is unplugged and switched OFF   
					before cleaning or attempting to store the item. NEVER PLUG OR   
					UNPLUG UNIT WITH WET HANDS.   
					DO NOT leave water in water tank or water basin when unit is not   
					in use as it may result in the build up of mineral deposits and   
					bacteria that can inhibit the output efficiency of the humidifier.   
					PLEASE NOTE that if water remains in the water tank for more   
					than a day or two, bacterial growth is possible.   
					ALWAYS use fresh cool water when using unit.   
					NOTE: When removing water tank, water may accumulate under vapor lid and on the   
					bottom of the water tank. It is recommended to have a dry cloth ready to dry wet   
					surfaces.   
					DISINFECTING THE WATER TANK AND WATER BASIN   
					1. Fill water tank with 1 teaspoon of household bleach in 1 gallon of water. Let   
					stand twenty minutes, shaking vigorously with two hands every few minutes,   
					drain and rinse with clean water until the bleach smell is gone. Dry with a clean   
					cloth or paper towel.   
					2. Wipe the water basin with a soft cloth dampened in the bleach and water   
					solution. Rinse the water basin with cool water to remove any bleach smell. DO   
					NOT IMMERSE WATER BASIN IN WATER.   
					3. Wipe all exteriors surfaces of the base with a soft, dry cloth. Do not immerse the   
					base in water or use water to clean the base. An electric shock may result or the   
					humidifier may be damaged.   
					NOTE: It is recommended to clean humidifier with water and bleach solution as stated   
					above after using the humidifier the fourth time.   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				GENERAL MAINTENANCE AND CLEANING   
					Before any cleaning operation, switch the humidifier off and unplug it.   
					1. Always unplug the unit before cleaning.   
					2. The humidifier must be drained and cleaned before storing.   
					3. Once unplugged the exterior of the unit may be cleaned by wiping with a soft dry   
					cloth. Caution: The ON/OFF switch must be thoroughly dry before unit is again   
					plugged into power source.   
					4. There may be some lime deposits in the nebulizer, particular in areas with hard   
					water. Overcome this drawback by cleaning the nebulizer with water and vinegar on   
					a soft cloth regularly, as follows:   
					A. Dampen a cloth with vinegar and wipe the nebulizer gently, until the lime   
					deposits disappear completely.   
					B. Rub down gently with a dry cloth and remove remains of humidity.   
					C. Do not rub the nebulizer with solid objects.   
					D. Do not clean with chemical products   
					5. When cleaning the water basin do not place the nebulizer directly under the water   
					tap.   
					6. Never immerse the unit in water or let water enter the fan vent (see figure 3) or   
					any other openings.   
					7. It is normal for water to be in the water basin. However water must not get inside   
					the central body. If this should happen, take the humidifier to an authorized service   
					center before using it again.   
					8. Clean the inside of the water tank at least once a week, as follows:   
					A. Fill the tank with clean water adding a few drops of bleach. Close the tank   
					completely with its cap and shake by holding the tank with both hands. Do   
					not hold by handle while shaking the tank.   
					B. Rinse thoroughly.   
					Water Level Sensor- The water level sensor is made of three key parts. When   
					cleaning DO NOT MISPLACE these parts and MAKE SURE that you assemble these three   
					parts correctly after cleaning and before operating humidifier. They are as follows:   
					Plastic Cap – this part has 4 flat tabs coming out from the bottom and is placed on top   
					of a plastic pin.   
					Water Float - a small round part resembling a “life saver” candy located underneath   
					the plastic cap.   
					Pin – plastic pin that secures water float and plastic cap.   
					To clean the water float unscrew the plastic cap from the pin. Remove the water float   
					and clean by wiping the parts with a soft damp cloth. Replace the parts by first putting   
					the water float onto the pin and re-screwing the plastic cap onto pin.   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				STORING YOUR HUMIDIFIER   
					Allow the appliance to dry completely before storing. Store the appliance in a dry   
					location. Do not place any heavy items on top of appliance during storage as this may   
					result in possible damage of the appliance. Store the cord in a clean, dry location away   
					from metal objects. Always check the plug before use to assure metal items have not   
					become attached.   
					 
					 
					Save the box for off-season storage.   
					Make sure the tank, water basin and water tank cap are thoroughly dry before   
					storing.   
					 
					If water is left in the unit during storage, it may evaporate completely and leave   
					deposits that can prevent the unit from operating properly.   
					Leave the water tank refill cap loose to prevent the water cap (see figure 4) and   
					gasket from sticking together. This will prolong the life of the gasket.   
					TROUBLE SHOOTING   
					CAUTION: DO NOT attempt to repair the motor or nebulizer yourself. If the   
					humidifier continues to not operate please call our service center (see toll free   
					number).   
					Problem   
					Solution   
					Humidifier power light is staying red and   
					not turning green   
					 
					Ensure that water level sensor is   
					assembled properly.   
					 
					 
					Clean water float   
					Call service center and request   
					Humidifier is working than stops:   
					replacement water float   
					 
					 
					If humidifier does not work at all:   
					Ensure it is properly plugged into a   
					power outlet.   
					 
					 
					Check that the switch is in the ON   
					position.   
					If Power On indicator light does not   
					come on, bring to authorized service   
					station.   
					If there is a strange odor:   
					 
					 
					Clean the tank with water and vinegar   
					or bleach and rinse with clean water.   
					Leave the tank open for some time   
					without the cap, in a cool place.   
					The power light is green but there is no   
					mist being emitted:   
					 
					 
					Check that there is water in the tank.   
					Check for possible lime deposits on the   
					water level sensor or the nebulizer (see   
					page 8 and 9).   
					 
					 
					Make sure that nothing blocks the   
					vapor output slots.   
					Check that the fan vent on bottom of   
					humidifier is not blocked.   
					 Empty the humidifier and rinse the   
					water basin with cool tap water and   
					allow to dry for 15 to 30 min.   
					White dust appears and settles outside the   
					humidifier:   
					 
					Area tap water may have too many   
					minerals, change to filtered or distilled   
					water.   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SERVICE CENTER   
					If you have any question in regards to the operation of this appliance or are in need of a   
					spare part please contact our service center at:   
					Crane USA Inc.   
					Tel: 1-888-599-0992 (Business Hours Mon-Fri 9:00am-4:00 pm Ct)   
					Website: http://www.crane-usa.com   
					1800 Nicholas Blvd   
					Elk Grove Village, Illinois 60007   
					ENVIRONMENTAL PROTECTION   
					If the appliance should no longer work at all, please make sure that it is disposed in an   
					environmentally friendly way, by handing it into a public collection point. Please do not   
					put it with your household waste.   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				LIMITED WARRANTY   
					Thank you for purchasing a top quality Crane product. This Ultrasonic Humidifier   
					was tested and meets our stringent quality standards. This product is warranted   
					to be free from manufacturing defects in original materials, including original   
					parts, and workmanship for 1 year with proof of purchase.   
					The warranty is void if the defect is due to accidental damage, misuse, abuse,   
					neglect, improper repair or alteration by unauthorized persons or failure to follow   
					operation instructions provided with the product. This warranty does not apply to   
					commercial use.   
					The warranty is non-transferable and applies only to the original purchase and   
					does not extend to subsequent owners of the product. Liability under this   
					warranty is limited to repair, replacement or refund. In no event shall liability   
					exceed the purchase price paid by the purchaser of the product. Under no   
					circumstances shall there be liability for any loss, direct, indirect, incidental,   
					special or consequential damage arising out of in connection with use of this   
					product. This warranty is valid only in the United States of America. This Warranty   
					gives you specific legal rights. However you may have other rights that vary from   
					state to state. Some states do not allow limitation on implied warranties or   
					exclusion of consequential damages therefore these restrictions may not apply to   
					you.   
					In case you find this product to be defective please proceed as follows:   
					A. within 90 days of purchase : return the product to your retailer for a refund   
					B. After 90 days and within the warranty period: send the product (freight   
					prepaid) to our service center. To avoid transport damages please send the   
					product in the original packaging. In return you will receive your repaired   
					item, a new product or a refund at the service center’s discretion.   
					Please fill out the Warranty Card and send it together with the product and   
					purchase receipt   
					To arrange pick-up of the defective item please call our service center:   
					Crane USA Inc.   
					Tel: 1-888-599-0992 (Business Hours Mon-Fri 9:00am-4:00 pm CT)   
					Website: http://www.crane-usa.com   
					1800 Nicholas Blvd   
					Elk Grove Village, Illinois 60007   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WARRANTY CARD   
					Ultrasonic Humidifier   
					In case you find this product to be defective please proceed as follows:   
					A. within 90 days of purchase : return the product to your retailer for a   
					refund   
					B. After 90 days and within the warranty period: send the product   
					(freight prepaid) to our service center. To avoid transport damages   
					please send the product in the original packaging. In return you will   
					receive your repaired item, a new product or a refund at the service   
					center’s discretion.   
					This Ultrasonic Humidifier was tested and meets our stringent quality   
					standards. This product is warranted to be free from manufacturing   
					defects in original materials, including original parts, and workmanship   
					for 1 year with proof of purchase.   
					Please print clearly and fill in your details below. Send it together with   
					the product and purchase receipt. Please read the Limited Warranty   
					conditions mentioned in this instruction manual.   
					Customer Name   
					Street   
					City   
					State   
					ZIP Code   
					Model #/Style   
					Purchase Date   
					Description of Defect :   
					Service Center Address   
					Crane USA Inc.   
					Tel: 1-888-599-0992 (Business Hours Mon-Fri 9:00am-4:00 pm CT)   
					Website: http://www.crane-usa.com   
					1800 Nicholas Blvd   
					Elk Grove Village, Illinois 60007   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ORDER FORM   
					FOR REPLACEMENT CRANE ADORABLE HUMIDIFIER WATER TANK   
					Price per Water Tank (includes shipping and handling $18.00)   
					Please send a MONEY ORDER only (no cash or personal checks),   
					Please use Street address only (we cannot ship to PO Boxes)   
					payable to Wachsmuth & Krogmann Inc. to the following address:   
					Crane Inc,   
					1800 Nicholas Blvd.   
					Elk Grove Village, IL 60007   
					Kindly fill in your information below and send together with your   
					Money Order. To avoid delay please print clearly.   
					Name   
					Street   
					City   
					State   
					ZIP   
					Phone #   
					Date   
					Model #/Style   
					Quantity of Parts   
					Total amount   
					Water Tank @ $   
					$ 